2. OVER VIEW
› High SD Drop found in most of the RBS2202 Cabinet
(Master Cabinet – 900 Band) in combination with
Other Slave Cabinets (1800 Band) Expansion Sites
(MBC Site)
›All the Drops (Cndrop) are Other reason drops
Ericsson Internal | 2011-11-21 | Page 2
3. Action taken
SD Shifting
drop
SD carrying time slot shifted
SD carrying TRX shifted
SD SD carrying Channel group shifted (like CHGR-high 0 to CHGR-1).
still actions the After all Ericsson Internal | 2011-11-21 | Page 3
Physical Audit
Cable Swap verified
Jumper to feeder cable Connection verified
Antenna faulty verified
Re Loading
TRX Swap and Replaced
TG Restart given
Hard Reset given
Site delete and recreation done.
Drive Test
Multiple calls initiated
4. Solutions
› Chennai Network Drop1% improved from 95.5 to 96.
Drop1% improved from 95.5 to 96.
› After above all the actions still high SD drop was observed.
› Trail basis two cells taken and SCLDSC settings Changed
from OL to UL.
› SD Drop was improved and no other reason drop found.
› All the RBS2202 cabinet with expansion sites dump taken
and changed the SCLDSC setting.
Ericsson Internal | 2011-11-21 | Page 4
6. Observation
› Problem due to Sync issue between 2202 cabinet to some other
cabinet (MBC cabinet).
› Sync issue problem analysis under progress.
Ericsson Internal | 2011-11-21 | Page 6