2642_en_H                                      © PHOENIX CONTACT 2011-07-10


1       Description                                               2       Features and Benefits
The FL SWITCH SFNB… Factoryline switches can be used              –   Increased network performance
for quick and cost-effective Ethernet network expansion to            – Switched Ethernet networks reduce traffic and non-
the field level. Due to the narrow housing design, the                    predictable timing
switches are suitable for use in control cabinets and junction    –   Easy network expansion
boxes. The switch supports the auto negotiation function
                                                                      – No configuration of the switch
and offers transmission speeds of 10/100 Mbps across
RJ45 ports and 100 Mbps across fiber optic ports. Mixed               – Auto-negotiation and autocross simplify cabling
operation for the connection of segments with different data          – Couple copper network segments with different bit
transmission speeds is also supported.                                    rates with automatic detection of the data
                                                                          transmission speed of 10 or 100 Mbps.
The RJ45 ports offer an autocrossing function, which means
it is not necessary to make a distinction between 1:1 and         –   Easy maintenance
crossover cables.                                                     – Individual LEDs at each port indicate
                                                                          communication activity and data rate
Switches are available with either SC or ST multi-mode fiber
optic ports. For longer distance, a single-mode fiber optic           – Removable power connector
switch extends the segment to 20 km typical.                          – Internal, resettable fuse
                                                                      – NS 35 DIN rail (EN 60715) compatible
                                                                  –   Fiber optic ports extend distance and provide electrical
                                                                      noise immunity
                                                                      – SC multi-mode, SC single-mode and ST multi-
                                                                          mode versions available
                                                                  –   Industrial rated
                                                                      – Rugged metal housing for industrial applications
                                                                      – -10 to 60°C operating range
                                                                      – Meets IEC 61000-6-2 electrical noise immunity
                                                                      – Meets IEC 60068-2-6 vibration test standards
                                                                      – Meets IEC 60068-2-27 shock test standards




         Make sure you always use the latest documentation.
         It can be downloaded at www.phoenixcontact.net/catalog.

         This data sheet is valid for all products listed on the following page:
FL SWITCH SFNB…



3        Ordering Data
Description                                                          Type                         Order No.       Pcs./Pkt.
Ethernet switch with 5 RJ45 ports                                    FL SWITCH SFNB 5TX           2891001         1
Ethernet switch with 8 RJ45 ports                                    FL SWITCH SFNB 8TX           2891002         1
Ethernet switch with 4 RJ45 ports and 1 SC format fiber optic port   FL SWITCH SFNB 4TX/FX        2891027         1
Ethernet switch with 4 RJ45 ports and 1 ST format fiber optic port   FL SWITCH SFNB 4TX/FX ST     2891028         1
Ethernet switch with 4 RJ45 ports and 1 SC format single-mode        FL SWITCH SFNB 4TX/FX SM20   2891029         1
fiber optic port


Accessories
Description                                                          Type                         Order No.       Pcs./Pkt.
Universal end clamp                                                  E/NS 35 N                    0800886         50
Patch angle with 2 ports in CAT 5e                                   FL PF 2TX CAT5E              2891165         1
Patch angle with 8 ports in CAT 5e                                   FL PF 8TX CAT5E              2891178         1
Patch angle with 2 ports in CAT 6                                    FL PF 2TX CAT6               2891068         1
Patch angle with 8 ports in CAT 6                                    FL PF 8TX CAT6               2891071         1
Patch angle with security elements for 2 ports in CAT 5e             FL PF SEC 2TX                2832687         1
Patch angle with security elements for 8 ports in CAT 5e             FL PF SEC 8TX                2832690         1
Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted          FL PBX 8TX                   2832496         1
Patch cable, CAT 5, pre-assembled, 0.3 m long                        FL CAT5 PATCH 0,3            2832250         10
Patch cable, CAT 5, pre-assembled, 0.5 m long                        FL CAT5 PATCH 0,5            2832263         10
Patch cable, CAT 5, pre-assembled, 1.0 m long                        FL CAT5 PATCH 1,0            2832276         10
Patch cable, CAT 5, pre-assembled, 1.5 m long                        FL CAT5 PATCH 1,5            2832221         10
Patch cable, CAT 5, pre-assembled, 2.0 m long                        FL CAT5 PATCH 2,0            2832289         10
Patch cable, CAT 5, pre-assembled, 3.0 m long                        FL CAT5 PATCH 3,0            2832292         10
Patch cable, CAT 5, pre-assembled, 5.0 m long                        FL CAT5 PATCH 5,0            2832580         10
Patch cable, CAT 5, pre-assembled, 7.5 m long                        FL CAT5 PATCH 7,5            2832616         10
Patch cable, CAT 5, pre-assembled, 10.0 m long                       FL CAT5 PATCH 10             2832629         10
Lockable security element for FL PATCH…                              FL PATCH GUARD               2891424         20
Key for FL PATCH GUARD                                               FL PATCH GUARD KEY           2891521         1
Color marker for FL PATCH GUARD, black                               FL PATCH GUARD CCODE BK      2891136         12
Color marker for FL PATCH GUARD, blue                                FL PATCH GUARD CCODE BU      2891233         12
Color marker for FL PATCH GUARD, orange                              FL PATCH GUARD CCODE OG      2891330         12
Color marker for FL PATCH GUARD, yellow                              FL PATCH GUARD CCODE YE      2891437         12
Color marker for FL PATCH GUARD, turquoise                           FL PATCH GUARD CCODE TQ      2891534         12
Color marker for FL PATCH GUARD, green                               FL PATCH GUARD CCODE GN      2891631         12
Color marker for FL PATCH GUARD, red                                 FL PATCH GUARD CCODE RD      2891738         12
Color marker for FL PATCH GUARD, violet                              FL PATCH GUARD CCODE VT      2891835         12




2642_en_H                                                                                                   PHOENIX CONTACT   2
FL SWITCH SFNB…



4          Technical Data
General Data
Function                                      Switch/repeater; conforms to standard IEEE 802.3
Latency of the communication processor
    FL SWITCH SFNB 5(4)TX…                    8 µs plus frame time
    FL SWITCH SFNB 8TX                        9 µs plus frame time
Housing dimensions (width x height x depth)
    FL SWITCH SFNB 5(4)TX…                    28 x 110 x 70 mm
    FL SWITCH SFNB 8TX                        50 x 110 x 70 mm
Weight
    FL SWITCH SFNB 5(4)TX…                    205 g
    FL SWITCH SFNB 8TX                        291 g
Operating temperature
    All models except FL SWITCH SFNB 4TX/FX   -10°C … 60°C
    FL SWITCH SFNB 4TX/FX                     0°C … 60°C
Storage temperature                           -20°C … 85°C
Degree of protection                          IP20, DIN 40050, IEC 60529
Protection class                              Class 3 VDE 0106; IEC 60536
Humidity (operation and storage)              5% to 95%, no condensation
Air pressure (operation)                      86 kPa to 108 kPa, 1500 m above sea level
Air pressure (storage)                        66 kPa to 108 kPa, 3500 m above sea level
Mounting rail                                 NS 35 (EN 60715)
Preferred mounting position                   Perpendicular to a standard mounting rail
Connection to protective earth ground         Snapped onto a grounded mounting rail


Supply Voltage (US)
Connection type                               Removable, screw-clamp connector
Wire size (solid/stranded/AWG)                0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG
Recommended PE wire size                      2.5 mm2
Nominal power supply                          24 V DC
Permissible ripple                            3.6 Vpp within the permissible voltage range
Permissible voltage range
    FL SWITCH SFNB 5(4)TX…                    12 V DC …48 V DC
    FL SWITCH SFNB 8TX                        9 V DC …32 V DC
Current consumption, nominal
    FL SWITCH SFNB 5TX                        180 mA@24 V DC; 340 mA@12 V DC
    FL SWITCH SFNB 8TX                        138 mA@24 V DC; 272 mA@12 V DC
    FL SWITCH SFNB 4TX/FX                     185 mA@24 V DC; 385 mA@12 V DC
    FL SWITCH SFNB 4TX/FX ST                  185 mA@24 V DC; 385 mA@12 V DC
    FL SWITCH SFNB 4TX/FS SM20                185 mA@24 V DC; 385 mA@12 V DC
Inrush current maximum
    FL SWITCH SFNB 5TX                        15 A for 35 µs
    FL SWITCH SFNB 8TX                        9.1 A for 40 µs
    FL SWITCH SFNB 4TX/FX                     7.2 A for 80 µs
    FL SWITCH SFNB 4TX/FX ST                  7.7 A for 80 µs
    FL SWITCH SFNB 4TX/FX SM20                7.7 A for 80 µs
Test voltage                                  500 V DC for one minute
Protection against polarity reversal          Present


Interfaces
Total number of Ethernet interfaces (RJ45)
    FL SWITCH SFNB 5TX                        5
    FL SWITCH SFNB 8TX                        8
    FL SWITCH SFNB 4TX…                       4
MAC Address Table Size (Entries)              2K
Properties of RJ45 Ports
    Connection format                         8-pos. RJ45 female connector on the switch



2642_en_H                                                                                      PHOENIX CONTACT   3
FL SWITCH SFNB…



Interfaces (Continued)
  Connection medium                                        Twisted-pair cable with a conductor cross section of 0.14 mm2 to 0.22 mm2
  Cable impedance                                          100 Ω
  Transmission speed                                       10/100 Mbps
  Maximum network segment length                           100 m
Properties of Fiber Optic Ports
Connection format                                          SC duplex or ST female connector
Fiber type                                                 Glass
Laser protection                                           Class 1 according to DIN EN 60825-1:2001-11
Properties of 100 Mbps Multimode
Transmission rate                                          100 Mbps full duplex
Wavelength                                                 1300/1310 nm
Fiber optic segment length                                 12.1 km with glass fiber 62.5/125 0.7 dB/km F1000
                                                           3.3 km with glass fiber 62.5/125 2.6 dB/km F600
                                                           7.1 km glass fiber with F-G 50/125 0.7 dB/km F1200
                                                           3.1 km glass fiber with F-G 50/125 1.6 dB/km F800
Transmission power (medium type) dynamic (average)
  Minimum                                                  -23.5 dBm (50/125 µm) / -20 dBm (62.5/125 µm)
  Maximum                                                  -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm)
Transmission power (medium type) static
  Minimum                                                  -22.5 dBm (50/125 µm) / -19 dBm (62.5/125 µm)
  Maximum                                                  -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm)
Receiver sensitivity
  Minimum                                                  -31 dBm (dynamic) / -31 dBm (static)
  Maximum                                                  -14 dBm (dynamic) / -14 dBm (static)
Properties of 100 Mbps single mode
Transmission rate                                          100 Mbps full duplex
Fiber type                                                 9/125 µm
Wavelength                                                 1310 nm
Maximum transmission length                                25 km with glass fiber 9/125 µm 0.5 dB/km
Transmission power
  Minimum                                                  -15 dBm
  Maximum                                                  -3 dBm
Receiver sensitivity
  Minimum                                                  -32 dBm
  Maximum                                                  -3 dBm


Mechanical Tests
Shock test according to IEC 60068-2-27                     Operation: 25g, 11 ms period, half-sine shock pulse
                                                           Storage/transport: 50g, 11 ms period, half-sine shock pulse
Vibration resistance according to IEC 60068-2-6            Operation/storage/transport: 5g, 150 Hz, Criterion 3
Free fall according to IEC 60068-2-32                      1m


Conformance With EMC Directives
Developed according to IEC 61000-6-2
  IEC 61000-4-2 (ESD)                                      Contact: ±4 kV, Criterion B
                                                           Air: ±8 kV, Criterion B
  IEC 61000-4-3 (radiated-noise immunity)                  10 V/m, Criterion A
  IEC 61000-4-4 (burst)                                    Ports: ±1 kV, Criterion B
                                                           DC power: ±2 kV, Criterion B
  IEC 61000-4-5 (surge)                                    Ports: ±1 kV, Criterion B
                                                           DC power: ±500 V, Criterion B
  IEC 61000-4-6 (conducted noise immunity)                 10 V/m, Criterion A
  IEC 61000-4-8 (noise immunity against magnetic fields)   30 A/m, Criterion A
  EN 55022 (noise emission)                                Class A




2642_en_H                                                                                                    PHOENIX CONTACT           4
FL SWITCH SFNB…




Approvals
General                                                               c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC
Hazardous location                                                    U Class 1, Division 2, Groups A, B, C, D Temp Code T5
                                                                      installed in minimum IP54 enclosure




5            Overview
                                                                       5.1        Diagnostic and Status Indicators
                                       1                                   Des.         Color        Status       Meaning
                                                                  1
                  FL SWITCH SFNB 5TX
                                                                             US         Green          ON         Supply voltage US in the
                                       2
                  Ord.No.2891001



             US
                                                                                                                  tolerance range
                               K/
                                                    US            2
                            LN                                                                        OFF         Supply voltage US too
                            AC
                               T
                                       3
    X1                                                                                                            low
                            10
                               0
                               K/
                                       4
                            LN                K/            K/
                               T           LN            LN
                            AC
                                           AC
                                              T
                                                         AC
                                                            T
                                                                  3    5.2        Data Transmission Speed LEDs (2 LEDs/Port)
    X2                                     X1            X2

                            10
                               0
                               K/
                                           10
                                              0
                                                         10
                                                            0     4                                   10 Mbps                 100 Mbps
                            LN                K/            K/
                               T           LN            LN
                            AC                T             T
                                           AC            AC

    X3                                     X3            X4
                                                                             LNK/ACT                 ON/blinking            ON/blinking
                                 0
                            10                  0             0

                            LN
                               K/
                                           10

                                           LN
                                              K/
                                                         10

                                                         LN
                                                            K/
                                                                                  100                       OFF                 ON
                               T
                            AC                T             T
                                           AC            AC

    X4                                     X5            X6

                            10
                                 0
                                           10
                                                0
                                                         10
                                                            0
                                                                                   LNK/ACT LED:
                                              K/            K/
                                           LN            LN
                                           AC
                                              T
                                                         AC
                                                            T
                                                                                   ON: indicates an electrical link
                                           X7            X8
                            LN
                            AC
                               K/
                               T                0             0
                                                                                   Flashing: indicates network traffic (at high data
                                           10            10

    X5                                                                             rates the blinking is in a constant rate)
                                 0
                            10




         1        Power connector
         2        Power LED (US) - green
         3        LNK/ACT LED - green
         4        100 LED - yellow

Figure 1                   Housing




2642_en_H                                                                                                            PHOENIX CONTACT      5
FL SWITCH SFNB…



6        Installation                                              by an additional low-impedance connection to functional
                                                                   earth ground (see Figure 2).
           CAUTION:
           Only qualified personnel may start up and operate                                 – +
           this device. Qualified personnel are persons                                                   24 V DC
           authorized to start up, ground and mark devices,
           systems, and equipment according to the
           standards of safety technology.
                                                                                            GND US
           NOTE:
           The FL SWITCH SFNB… module is designed for




                                                                                X6
           SELV and PELV operation according to
           IEC 61140/EN 61140.

Install the FL SWITCH SFNB… on a clean mounting rail. To
avoid contact resistance only use clean, corrosion-free
mounting rails that meet the EN 60715 standard. End                Figure 2     Power connections
clamps can be mounted on both sides of the module to stop
the modules from slipping on the rail.                             Use power conductors between 0.2 - 2.5 mm²
                                                                   (24 - 12 AWG). Torque connection screws to 0.5 - 0.6 Nm
           NOTE:                                                   (5 - 7 lb-in.).
           Connect the mounting rail to protective earth           6.4     Ethernet Interface
           ground using a grounding terminal block. The
           modules are grounded when they are snapped              The FL SWITCH SFNB… has either five or eight Ethernet
           onto the rail. Connect protective earth ground          ports on the front in RJ45 format to which only twisted-pair
           with low impedance.                                     cables with an impedance of 100 Ω can be connected. The
                                                                   data transmission speed is 10/100 Mbps. In addition, every
6.1      Assembly                                                  port has an auto crossing function: it is not necessary to
                                                                   make a distinction between 1:1 or crossover Ethernet
1.    Place the module onto the rail from above. The upper         cables.
      holding keyway must be hooked onto the top edge of
      the rail.
2.    Push the module from the front towards the mounting
      surface.                                                                                    RJ45
3.    Once the module has been snapped on properly, check
      that it is fixed securely on the rail.

6.2      Removal
1.    Insert a suitable tool (e.g., needle-nose pliers) into the
      arresting latch and pull it down.
2.    Pull the module slightly away from the mounting                                   8 7 6 5       4 3 2 1
                                                                                       n.c. TD-      n.c. RD-
      surface.                                                                             n.c. n.c.    TD+ RD+
3.    Lift the module from the rail.
                                                                   Figure 3     RJ45 pin assignment
6.3      Power Connection
The switch is designed for SELV and PELV operation at
+24 V DC according to IEC 61140/EN 61140. Only SELV
and PELV according to the defined standards may be used
for supply purposes.
Snapping the switch onto a grounded mounting rail
connects it to the ground potential. In an environment
particularly prone to EMI, noise immunity can be increased


2642_en_H                                                                                                PHOENIX CONTACT      6
FL SWITCH SFNB…



6.5      Fiber Optic Connection                                                            8         Dimensions
Two different types of fiber optic connection are available.
                                                                                                                                               14 mm
– The ST connectors are typically individual round
   connectors and use a 1/4-turn connection.                                                               FL SWITCH SFNB 5TX
                                                                                                           Ord.No.2891001



                                                                                                      US
– The SC connectors have a square interface and the                                                                                                              US
                                                                                                                        K/
                                                                                                                     LN
   “conductors” are typically locked together through the                                                            AC
                                                                                                                        T


                                                                                               X1
   connector.
                                                                                                                        0
                                                                                                                     10
                                 K/                                             K/                                      K/
                              LN                                              LN                                                                          K/                     K/
                                  T                                               T                                  LN
      SC Connectors            AC
                                                    ST Connectors              AC
                                                                                                                     AC
                                                                                                                        T                              LN
                                                                                                                                                       AC
                                                                                                                                                          T
                                                                                                                                                                              LN
                                                                                                                                                                              AC
                                                                                                                                                                                 T

                              X6                                              X6               X2                                                      X1                     X2
                                                                              100
                                                                                                                        0
                                                                                                                     10                                     0                    0
                                                                                                                                                       10                     10
                100
                         K/
                       LN T
                        AC
                                         TD                      100
                                                                         K/
                                                                       LN T
                                                                        AC
                                                                                      TD                             LN
                                                                                                                        K/
                                                                                                                        T                              LN
                                                                                                                                                          K/
                                                                                                                                                                              LN
                                                                                                                                                                                 K/
                                                                                                                     AC                                   T                      T
                                                                                                                                                       AC                     AC




                                                                                                                                      110 mm
                                                            TD
                                                                                               X3                                                      X3                     X4
           X5                                          X5                                                                 0
                                                                                                                     10                                     0                    0
                                                                                                                                                       10                     10
                                         RD                 RD                        RD                             LN
                                                                                                                        K
                                                                                                                        T
                                                                                                                              /
                                                                                                                                                       LN
                                                                                                                                                          K/
                                                                                                                                                                              LN
                                                                                                                                                                                 K/
                                                                                                                     AC                                   T                      T
                                                                                                                                                       AC                     AC

                                                                                               X4                                                      X5                     X6

                                                                                                                          0
                                                                                                                     10                                     0                    0
                                                                                                                                                       10                     10
                                                                                                                                                            K/                   K/
                                                                                                                                                       LN                     LN
                                                                                                                                                          T                      T
                                                                                                                                                       AC                     AC

Figure 4              Fiber optic ports                                                                                 K/
                                                                                                                                                       X7                     X8
                                                                                                                     LN
                                                                                                                        T                                   0                      0
                                                                                                                     AC                                10                     10

                                                                                               X5


7        Switching Characteristics                                                                                   10
                                                                                                                          0




–     Store and Forward
      All data telegrams received by the switch are saved and                                       28 mm                                                             50 mm
      their validity checked. Invalid or faulty data packets                                                                      Depth = 70 mm
      (> 1522 bytes or CRC errors) and fragments
      (< 64 bytes) are rejected. Valid data telegrams are                                  Figure 5               Housing dimensions
      forwarded by the switch. The switch always forwards
      the data using the data transmission speed that is used
      in the destination network segment.
–     Multi-Address Function
      The switch independently learns the addresses for
      termination devices, which are connected via a port, by
      evaluating the source addresses in the data telegrams.
      Only packets with unknown addresses, with a source
      address of this port or with a multicast/broadcast
      address in the destination address field are forwarded
      via the corresponding port. The switch can store
      addresses in its address table with an aging time of
      5 minutes. This is important when more than one
      termination device is connected to one or more ports. In
      this way, several independent subnetworks can be
      connected to one switch.

            A restart deletes the entire address table.




2642_en_H                              PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00                                                             7
                                      PHOENIX CONTACT • P.O. Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300
                                                                    www.phoenixcontact.com

More Related Content

What's hot

데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
HION IT
 
Advanced motion controls dpqnnie 020b080
Advanced motion controls dpqnnie 020b080Advanced motion controls dpqnnie 020b080
Advanced motion controls dpqnnie 020b080
Electromate
 
Advanced motion controls dpqnnie 030a800
Advanced motion controls dpqnnie 030a800Advanced motion controls dpqnnie 030a800
Advanced motion controls dpqnnie 030a800
Electromate
 
Advanced motion controls dpqnnie 015b200
Advanced motion controls dpqnnie 015b200Advanced motion controls dpqnnie 015b200
Advanced motion controls dpqnnie 015b200
Electromate
 
Advanced motion controls dpqnnie 060a400
Advanced motion controls dpqnnie 060a400Advanced motion controls dpqnnie 060a400
Advanced motion controls dpqnnie 060a400
Electromate
 
Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)
Ari Zoldan
 
Advanced motion controls dzralte 010l200
Advanced motion controls dzralte 010l200Advanced motion controls dzralte 010l200
Advanced motion controls dzralte 010l200
Electromate
 

What's hot (19)

Ia r6000-c-r1-1
Ia r6000-c-r1-1Ia r6000-c-r1-1
Ia r6000-c-r1-1
 
Mc 802 field-evaluation
Mc 802 field-evaluationMc 802 field-evaluation
Mc 802 field-evaluation
 
H355
H355H355
H355
 
GPS-320FW
GPS-320FWGPS-320FW
GPS-320FW
 
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
데이타로직 Datalogic DS6300 1D 산업용 고정식 바코드스캐너 레이저스캐너 매뉴얼
 
Advanced motion controls dpqnnie 020b080
Advanced motion controls dpqnnie 020b080Advanced motion controls dpqnnie 020b080
Advanced motion controls dpqnnie 020b080
 
VIPA SLIO Introduction
VIPA SLIO IntroductionVIPA SLIO Introduction
VIPA SLIO Introduction
 
Advanced motion controls dpqnnie 030a800
Advanced motion controls dpqnnie 030a800Advanced motion controls dpqnnie 030a800
Advanced motion controls dpqnnie 030a800
 
LayerZero Series 70: eRDP Remote Distribution Panel
LayerZero Series 70: eRDP Remote Distribution PanelLayerZero Series 70: eRDP Remote Distribution Panel
LayerZero Series 70: eRDP Remote Distribution Panel
 
2 page s40 data sheet
2 page s40 data sheet2 page s40 data sheet
2 page s40 data sheet
 
LS-RDIO0202 wireless I/O module 2DI 2DO wireless ON-OFF control
LS-RDIO0202 wireless I/O module 2DI 2DO wireless ON-OFF controlLS-RDIO0202 wireless I/O module 2DI 2DO wireless ON-OFF control
LS-RDIO0202 wireless I/O module 2DI 2DO wireless ON-OFF control
 
Advanced motion controls dpqnnie 015b200
Advanced motion controls dpqnnie 015b200Advanced motion controls dpqnnie 015b200
Advanced motion controls dpqnnie 015b200
 
Advanced motion controls dpqnnie 060a400
Advanced motion controls dpqnnie 060a400Advanced motion controls dpqnnie 060a400
Advanced motion controls dpqnnie 060a400
 
The flexible cisco aironet 1530 series access points
The flexible cisco aironet 1530 series access pointsThe flexible cisco aironet 1530 series access points
The flexible cisco aironet 1530 series access points
 
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP-SL2 Slim Remote Power PanelLayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
LayerZero Series 70: eRPP-SL2 Slim Remote Power Panel
 
BlueOptics X2 to SFP+ Converter 10Gigabit
BlueOptics X2 to SFP+ Converter 10GigabitBlueOptics X2 to SFP+ Converter 10Gigabit
BlueOptics X2 to SFP+ Converter 10Gigabit
 
Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)
 
LS-RDIO0808 PLC Wireless link module Modbus RTU
LS-RDIO0808 PLC Wireless link module Modbus RTULS-RDIO0808 PLC Wireless link module Modbus RTU
LS-RDIO0808 PLC Wireless link module Modbus RTU
 
Advanced motion controls dzralte 010l200
Advanced motion controls dzralte 010l200Advanced motion controls dzralte 010l200
Advanced motion controls dzralte 010l200
 

Similar to 2642 en h

11.greatway triple playproposal110422
11.greatway triple playproposal11042211.greatway triple playproposal110422
11.greatway triple playproposal110422
carlosvicunav
 
Efapel tabela precos mercado nacional 2013-01-01
Efapel tabela precos mercado nacional 2013-01-01Efapel tabela precos mercado nacional 2013-01-01
Efapel tabela precos mercado nacional 2013-01-01
Miguel Silva
 

Similar to 2642 en h (20)

Quest technology product training 8 13-14
Quest technology product training 8 13-14Quest technology product training 8 13-14
Quest technology product training 8 13-14
 
11.greatway triple playproposal110422
11.greatway triple playproposal11042211.greatway triple playproposal110422
11.greatway triple playproposal110422
 
2013 datwyler training 2 product overview - info tech middle east
2013 datwyler training 2   product overview - info tech middle east2013 datwyler training 2   product overview - info tech middle east
2013 datwyler training 2 product overview - info tech middle east
 
Panduit tx6000 utp-copcable-w
Panduit tx6000 utp-copcable-wPanduit tx6000 utp-copcable-w
Panduit tx6000 utp-copcable-w
 
NETVIEL-2015.pptx
NETVIEL-2015.pptxNETVIEL-2015.pptx
NETVIEL-2015.pptx
 
Nexans Euromold Interface A 200 Series Screened Cable Connectors
Nexans Euromold Interface A 200 Series Screened Cable Connectors Nexans Euromold Interface A 200 Series Screened Cable Connectors
Nexans Euromold Interface A 200 Series Screened Cable Connectors
 
Nexans Euromold MV Separable Connectors & Bushings - Interface A
Nexans Euromold MV Separable Connectors & Bushings - Interface ANexans Euromold MV Separable Connectors & Bushings - Interface A
Nexans Euromold MV Separable Connectors & Bushings - Interface A
 
Sommer cable catalogue section 3
Sommer cable catalogue section 3Sommer cable catalogue section 3
Sommer cable catalogue section 3
 
Copper and Fiber Basic Technician’s Kit
Copper and Fiber Basic Technician’s KitCopper and Fiber Basic Technician’s Kit
Copper and Fiber Basic Technician’s Kit
 
Efapel tabela precos mercado nacional 2013-01-01
Efapel tabela precos mercado nacional 2013-01-01Efapel tabela precos mercado nacional 2013-01-01
Efapel tabela precos mercado nacional 2013-01-01
 
Copper connecivity
Copper connecivityCopper connecivity
Copper connecivity
 
Martin dmx-5-3-splitter
Martin dmx-5-3-splitterMartin dmx-5-3-splitter
Martin dmx-5-3-splitter
 
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
 
Nexans Euromold MV Separable Connectors & Bushings - Interface C Symmetrical
Nexans Euromold MV Separable Connectors & Bushings - Interface C SymmetricalNexans Euromold MV Separable Connectors & Bushings - Interface C Symmetrical
Nexans Euromold MV Separable Connectors & Bushings - Interface C Symmetrical
 
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
 
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
 
Crabtree White EWA Catalogue
Crabtree White EWA CatalogueCrabtree White EWA Catalogue
Crabtree White EWA Catalogue
 
Upcom product overview 2018 www.upcom.com.tr
Upcom product overview 2018 www.upcom.com.trUpcom product overview 2018 www.upcom.com.tr
Upcom product overview 2018 www.upcom.com.tr
 
Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01Fiber optics catalogue_ver2.01
Fiber optics catalogue_ver2.01
 
Lika Profinet encoders overview
Lika Profinet encoders overviewLika Profinet encoders overview
Lika Profinet encoders overview
 

Recently uploaded

Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
panagenda
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
WSO2
 

Recently uploaded (20)

Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..
 
JohnPollard-hybrid-app-RailsConf2024.pptx
JohnPollard-hybrid-app-RailsConf2024.pptxJohnPollard-hybrid-app-RailsConf2024.pptx
JohnPollard-hybrid-app-RailsConf2024.pptx
 
Introduction to Multilingual Retrieval Augmented Generation (RAG)
Introduction to Multilingual Retrieval Augmented Generation (RAG)Introduction to Multilingual Retrieval Augmented Generation (RAG)
Introduction to Multilingual Retrieval Augmented Generation (RAG)
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 AmsterdamDEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
DEV meet-up UiPath Document Understanding May 7 2024 Amsterdam
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot ModelMcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
Apidays New York 2024 - APIs in 2030: The Risk of Technological Sleepwalk by ...
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 

2642 en h

  • 1. FL SWITCH SFNB… Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H © PHOENIX CONTACT 2011-07-10 1 Description 2 Features and Benefits The FL SWITCH SFNB… Factoryline switches can be used – Increased network performance for quick and cost-effective Ethernet network expansion to – Switched Ethernet networks reduce traffic and non- the field level. Due to the narrow housing design, the predictable timing switches are suitable for use in control cabinets and junction – Easy network expansion boxes. The switch supports the auto negotiation function – No configuration of the switch and offers transmission speeds of 10/100 Mbps across RJ45 ports and 100 Mbps across fiber optic ports. Mixed – Auto-negotiation and autocross simplify cabling operation for the connection of segments with different data – Couple copper network segments with different bit transmission speeds is also supported. rates with automatic detection of the data transmission speed of 10 or 100 Mbps. The RJ45 ports offer an autocrossing function, which means it is not necessary to make a distinction between 1:1 and – Easy maintenance crossover cables. – Individual LEDs at each port indicate communication activity and data rate Switches are available with either SC or ST multi-mode fiber optic ports. For longer distance, a single-mode fiber optic – Removable power connector switch extends the segment to 20 km typical. – Internal, resettable fuse – NS 35 DIN rail (EN 60715) compatible – Fiber optic ports extend distance and provide electrical noise immunity – SC multi-mode, SC single-mode and ST multi- mode versions available – Industrial rated – Rugged metal housing for industrial applications – -10 to 60°C operating range – Meets IEC 61000-6-2 electrical noise immunity – Meets IEC 60068-2-6 vibration test standards – Meets IEC 60068-2-27 shock test standards Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page:
  • 2. FL SWITCH SFNB… 3 Ordering Data Description Type Order No. Pcs./Pkt. Ethernet switch with 5 RJ45 ports FL SWITCH SFNB 5TX 2891001 1 Ethernet switch with 8 RJ45 ports FL SWITCH SFNB 8TX 2891002 1 Ethernet switch with 4 RJ45 ports and 1 SC format fiber optic port FL SWITCH SFNB 4TX/FX 2891027 1 Ethernet switch with 4 RJ45 ports and 1 ST format fiber optic port FL SWITCH SFNB 4TX/FX ST 2891028 1 Ethernet switch with 4 RJ45 ports and 1 SC format single-mode FL SWITCH SFNB 4TX/FX SM20 2891029 1 fiber optic port Accessories Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 Lockable security element for FL PATCH… FL PATCH GUARD 2891424 20 Key for FL PATCH GUARD FL PATCH GUARD KEY 2891521 1 Color marker for FL PATCH GUARD, black FL PATCH GUARD CCODE BK 2891136 12 Color marker for FL PATCH GUARD, blue FL PATCH GUARD CCODE BU 2891233 12 Color marker for FL PATCH GUARD, orange FL PATCH GUARD CCODE OG 2891330 12 Color marker for FL PATCH GUARD, yellow FL PATCH GUARD CCODE YE 2891437 12 Color marker for FL PATCH GUARD, turquoise FL PATCH GUARD CCODE TQ 2891534 12 Color marker for FL PATCH GUARD, green FL PATCH GUARD CCODE GN 2891631 12 Color marker for FL PATCH GUARD, red FL PATCH GUARD CCODE RD 2891738 12 Color marker for FL PATCH GUARD, violet FL PATCH GUARD CCODE VT 2891835 12 2642_en_H PHOENIX CONTACT 2
  • 3. FL SWITCH SFNB… 4 Technical Data General Data Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor FL SWITCH SFNB 5(4)TX… 8 µs plus frame time FL SWITCH SFNB 8TX 9 µs plus frame time Housing dimensions (width x height x depth) FL SWITCH SFNB 5(4)TX… 28 x 110 x 70 mm FL SWITCH SFNB 8TX 50 x 110 x 70 mm Weight FL SWITCH SFNB 5(4)TX… 205 g FL SWITCH SFNB 8TX 291 g Operating temperature All models except FL SWITCH SFNB 4TX/FX -10°C … 60°C FL SWITCH SFNB 4TX/FX 0°C … 60°C Storage temperature -20°C … 85°C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 5% to 95%, no condensation Air pressure (operation) 86 kPa to 108 kPa, 1500 m above sea level Air pressure (storage) 66 kPa to 108 kPa, 3500 m above sea level Mounting rail NS 35 (EN 60715) Preferred mounting position Perpendicular to a standard mounting rail Connection to protective earth ground Snapped onto a grounded mounting rail Supply Voltage (US) Connection type Removable, screw-clamp connector Wire size (solid/stranded/AWG) 0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG Recommended PE wire size 2.5 mm2 Nominal power supply 24 V DC Permissible ripple 3.6 Vpp within the permissible voltage range Permissible voltage range FL SWITCH SFNB 5(4)TX… 12 V DC …48 V DC FL SWITCH SFNB 8TX 9 V DC …32 V DC Current consumption, nominal FL SWITCH SFNB 5TX 180 mA@24 V DC; 340 mA@12 V DC FL SWITCH SFNB 8TX 138 mA@24 V DC; 272 mA@12 V DC FL SWITCH SFNB 4TX/FX 185 mA@24 V DC; 385 mA@12 V DC FL SWITCH SFNB 4TX/FX ST 185 mA@24 V DC; 385 mA@12 V DC FL SWITCH SFNB 4TX/FS SM20 185 mA@24 V DC; 385 mA@12 V DC Inrush current maximum FL SWITCH SFNB 5TX 15 A for 35 µs FL SWITCH SFNB 8TX 9.1 A for 40 µs FL SWITCH SFNB 4TX/FX 7.2 A for 80 µs FL SWITCH SFNB 4TX/FX ST 7.7 A for 80 µs FL SWITCH SFNB 4TX/FX SM20 7.7 A for 80 µs Test voltage 500 V DC for one minute Protection against polarity reversal Present Interfaces Total number of Ethernet interfaces (RJ45) FL SWITCH SFNB 5TX 5 FL SWITCH SFNB 8TX 8 FL SWITCH SFNB 4TX… 4 MAC Address Table Size (Entries) 2K Properties of RJ45 Ports Connection format 8-pos. RJ45 female connector on the switch 2642_en_H PHOENIX CONTACT 3
  • 4. FL SWITCH SFNB… Interfaces (Continued) Connection medium Twisted-pair cable with a conductor cross section of 0.14 mm2 to 0.22 mm2 Cable impedance 100 Ω Transmission speed 10/100 Mbps Maximum network segment length 100 m Properties of Fiber Optic Ports Connection format SC duplex or ST female connector Fiber type Glass Laser protection Class 1 according to DIN EN 60825-1:2001-11 Properties of 100 Mbps Multimode Transmission rate 100 Mbps full duplex Wavelength 1300/1310 nm Fiber optic segment length 12.1 km with glass fiber 62.5/125 0.7 dB/km F1000 3.3 km with glass fiber 62.5/125 2.6 dB/km F600 7.1 km glass fiber with F-G 50/125 0.7 dB/km F1200 3.1 km glass fiber with F-G 50/125 1.6 dB/km F800 Transmission power (medium type) dynamic (average) Minimum -23.5 dBm (50/125 µm) / -20 dBm (62.5/125 µm) Maximum -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm) Transmission power (medium type) static Minimum -22.5 dBm (50/125 µm) / -19 dBm (62.5/125 µm) Maximum -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm) Receiver sensitivity Minimum -31 dBm (dynamic) / -31 dBm (static) Maximum -14 dBm (dynamic) / -14 dBm (static) Properties of 100 Mbps single mode Transmission rate 100 Mbps full duplex Fiber type 9/125 µm Wavelength 1310 nm Maximum transmission length 25 km with glass fiber 9/125 µm 0.5 dB/km Transmission power Minimum -15 dBm Maximum -3 dBm Receiver sensitivity Minimum -32 dBm Maximum -3 dBm Mechanical Tests Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1m Conformance With EMC Directives Developed according to IEC 61000-6-2 IEC 61000-4-2 (ESD) Contact: ±4 kV, Criterion B Air: ±8 kV, Criterion B IEC 61000-4-3 (radiated-noise immunity) 10 V/m, Criterion A IEC 61000-4-4 (burst) Ports: ±1 kV, Criterion B DC power: ±2 kV, Criterion B IEC 61000-4-5 (surge) Ports: ±1 kV, Criterion B DC power: ±500 V, Criterion B IEC 61000-4-6 (conducted noise immunity) 10 V/m, Criterion A IEC 61000-4-8 (noise immunity against magnetic fields) 30 A/m, Criterion A EN 55022 (noise emission) Class A 2642_en_H PHOENIX CONTACT 4
  • 5. FL SWITCH SFNB… Approvals General c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC Hazardous location U Class 1, Division 2, Groups A, B, C, D Temp Code T5 installed in minimum IP54 enclosure 5 Overview 5.1 Diagnostic and Status Indicators 1 Des. Color Status Meaning 1 FL SWITCH SFNB 5TX US Green ON Supply voltage US in the 2 Ord.No.2891001 US tolerance range K/ US 2 LN OFF Supply voltage US too AC T 3 X1 low 10 0 K/ 4 LN K/ K/ T LN LN AC AC T AC T 3 5.2 Data Transmission Speed LEDs (2 LEDs/Port) X2 X1 X2 10 0 K/ 10 0 10 0 4 10 Mbps 100 Mbps LN K/ K/ T LN LN AC T T AC AC X3 X3 X4 LNK/ACT ON/blinking ON/blinking 0 10 0 0 LN K/ 10 LN K/ 10 LN K/ 100 OFF ON T AC T T AC AC X4 X5 X6 10 0 10 0 10 0 LNK/ACT LED: K/ K/ LN LN AC T AC T ON: indicates an electrical link X7 X8 LN AC K/ T 0 0 Flashing: indicates network traffic (at high data 10 10 X5 rates the blinking is in a constant rate) 0 10 1 Power connector 2 Power LED (US) - green 3 LNK/ACT LED - green 4 100 LED - yellow Figure 1 Housing 2642_en_H PHOENIX CONTACT 5
  • 6. FL SWITCH SFNB… 6 Installation by an additional low-impedance connection to functional earth ground (see Figure 2). CAUTION: Only qualified personnel may start up and operate – + this device. Qualified personnel are persons 24 V DC authorized to start up, ground and mark devices, systems, and equipment according to the standards of safety technology. GND US NOTE: The FL SWITCH SFNB… module is designed for X6 SELV and PELV operation according to IEC 61140/EN 61140. Install the FL SWITCH SFNB… on a clean mounting rail. To avoid contact resistance only use clean, corrosion-free mounting rails that meet the EN 60715 standard. End Figure 2 Power connections clamps can be mounted on both sides of the module to stop the modules from slipping on the rail. Use power conductors between 0.2 - 2.5 mm² (24 - 12 AWG). Torque connection screws to 0.5 - 0.6 Nm NOTE: (5 - 7 lb-in.). Connect the mounting rail to protective earth 6.4 Ethernet Interface ground using a grounding terminal block. The modules are grounded when they are snapped The FL SWITCH SFNB… has either five or eight Ethernet onto the rail. Connect protective earth ground ports on the front in RJ45 format to which only twisted-pair with low impedance. cables with an impedance of 100 Ω can be connected. The data transmission speed is 10/100 Mbps. In addition, every 6.1 Assembly port has an auto crossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet 1. Place the module onto the rail from above. The upper cables. holding keyway must be hooked onto the top edge of the rail. 2. Push the module from the front towards the mounting surface. RJ45 3. Once the module has been snapped on properly, check that it is fixed securely on the rail. 6.2 Removal 1. Insert a suitable tool (e.g., needle-nose pliers) into the arresting latch and pull it down. 2. Pull the module slightly away from the mounting 8 7 6 5 4 3 2 1 n.c. TD- n.c. RD- surface. n.c. n.c. TD+ RD+ 3. Lift the module from the rail. Figure 3 RJ45 pin assignment 6.3 Power Connection The switch is designed for SELV and PELV operation at +24 V DC according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. Snapping the switch onto a grounded mounting rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased 2642_en_H PHOENIX CONTACT 6
  • 7. FL SWITCH SFNB… 6.5 Fiber Optic Connection 8 Dimensions Two different types of fiber optic connection are available. 14 mm – The ST connectors are typically individual round connectors and use a 1/4-turn connection. FL SWITCH SFNB 5TX Ord.No.2891001 US – The SC connectors have a square interface and the US K/ LN “conductors” are typically locked together through the AC T X1 connector. 0 10 K/ K/ K/ LN LN K/ K/ T T LN SC Connectors AC ST Connectors AC AC T LN AC T LN AC T X6 X6 X2 X1 X2 100 0 10 0 0 10 10 100 K/ LN T AC TD 100 K/ LN T AC TD LN K/ T LN K/ LN K/ AC T T AC AC 110 mm TD X3 X3 X4 X5 X5 0 10 0 0 10 10 RD RD RD LN K T / LN K/ LN K/ AC T T AC AC X4 X5 X6 0 10 0 0 10 10 K/ K/ LN LN T T AC AC Figure 4 Fiber optic ports K/ X7 X8 LN T 0 0 AC 10 10 X5 7 Switching Characteristics 10 0 – Store and Forward All data telegrams received by the switch are saved and 28 mm 50 mm their validity checked. Invalid or faulty data packets Depth = 70 mm (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are Figure 5 Housing dimensions forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. – Multi-Address Function The switch independently learns the addresses for termination devices, which are connected via a port, by evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. A restart deletes the entire address table. 2642_en_H PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 7 PHOENIX CONTACT • P.O. Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com