Potentially Explosive
Atmospheres Requirements
  Understand the differences between
  European and North American rules




                           Intertek
                      1-800-WORLDLAB

         icenter@intertek.com   www.intertek-hazloc.com
Hazardous locations:
                                                          EU & NA requirements




Overview

The Explosive Atmospheres market is both lucrative and expanding, but the
level of certification requirements and the level of checking (both by the buyer
and by the regulatory authorities) are increasing. In order to access this market
it is imperative that equipment manufacturers understand the design,
manufacture and certification requirements on both discrete apparatus and
assemblies (rigs and skids) to ensure that the products are designed without
adding unnecessary costs and that the products are certified on time and
correctly. To facilitate this, Intertek can help with design advice, training and
complete global certification at multiple locations worldwide.


Introduction

What is Potentially Explosive Atmosphere Certification and why might you
need it?

Any industry that processes, uses or manufactures materials that may give rise
to a flammable atmosphere (gas, mist, liquid, dusts or even small fibres) may
have a potentially explosive atmosphere. Such industries/processes include:

   •   Oil and Gas Drilling
   •   Petrochemical Refining and
       Processing
   •   Fuel Storage
   •   Chemical manufacturing
   •   Car Manufacturing
   •   Water Treatment
   •   Power Generation
   •   Pharmaceutical
   •   Distilleries
   •   Food manufacturers
   •   Aviation
   •   Military




www.intertek-hazloc.com
Hazardous locations:
                                                           EU & NA requirements




Where fuel and oxygen (normally the oxygen in air) are present in the
workplace, potential ignition sources must be rendered safe to an acceptable
level for the risk.

Industries that generate potentially explosive atmospheres classify the
dangerous areas based on the likelihood and duration of the explosive
atmospheres presence. This is referred to as a ‘Zone’ (Europe and NEC505) or
‘Division’ (NEC500).

When a Zone or Division has been established, special precautions must be
taken by the manufacturer to reduce the likelihood of an ignition being present
to an acceptable level (and possibly to use mitigation measures to lower the
consequence of an explosion).

Given the onerous nature of an explosion, special certification schemes have
been set up to control the design and certification of equipment for potentially
explosive atmospheres. Although the schemes differ globally (some are
mandatory under law, some are simply procurement specifications), the bases
for design and certification is similar, and the schemes normally rely on
empirical testing, constructional assessment and production control by a
recognised Certification Body.

Manufacturers of electrical equipment (and non-electrical for Europe) must be
aware that if they sell to industries that have potentially explosive atmospheres
(the vast majority of industries) they may be asked for ‘certification’, and that
often the equipment will need to be certified by a Notified or NRTL Body such
as Intertek.




www.intertek-hazloc.com
Hazardous locations:
                                                            EU & NA requirements




Part 1: Zones & Divisions

What are the differences between the Zone and Division systems in
hazardous (classified) locations? What do the terms Zone and Division
mean and what are their similarities and differences?

The aim of both is to achieve safety by identifying areas where ignition sources
should be eliminated or ensuring that the ignition source is non-effective. Until
the advent of ATEX in July 2003, the most prevalent ignition sources where
those associated with electrical equipment e.g. electrical arcing or electrically
heated surfaces. Both systems work with the same natural laws of physics and
chemistry, such as gas ignition temperatures and combustible percentages of
volatile gases.

In 1947, the NEC first recognized different levels of risk exist in hazardous
locations. Consequently, it established Division 1 and Division 2, to provide a
means to treat the issue. This permitted installation methods to be specified,
based upon what was considered to be an acceptable level of risk.

The IEC recognized the NEC divisions were based more on whether the hazard
was present under either normal or abnormal conditions, instead of on the
duration of the hazard. Therefore, the IEC established three divisions, or Zones,
that are based on how often the hazard is present rather than upon normal
versus abnormal conditions. The three zones break the NEC's Division 1 into
two distinct zones, one of which (Zone 0) is for those locations that are the most
hazardous because they remain hazardous for a long time. Separating Zone 0
from the remainder of what is Division 1 in the NEC system permits a more
refined treatment of the hazards of the two zones. It restricts methods of
protection in Zone 0 while permitting more relaxed method of protection in Zone
1 locations.

The NEC Committee rewrote Article 505 because the Division Classification
system and IEC system are too different to merge. The IEC and NEC Group
classifications for the different gases in ascending order of "More Easily
Ignitable." Note that the group denoted with an "A" in the IEC area is the least
ignitable, while the group denoted with an "A" in the NEC group is the most
ignitable. Also, the IEC system uses three sub-groups for the representative
gases while the NEC system uses four. To further confuse the two systems, the
IEC and NEC do not use the same terminology, and neither have the same
number of categories [1] (zones) to identify the likelihood of the hazard being
present.

Standards
The American Petroleum Institute (API) RP 500, Recommended Practice for
Classification of Locations for Electrical Installations at Petroleum Facilities

www.intertek-hazloc.com
Hazardous locations:
                                                            EU & NA requirements




Classified as Class I Division I and Division 2, defines the extent of classified
areas in refineries operating under the Division system.

The National Fire Protection Association (NFPA) published NFPA Codes 497
recommended practice for the classification of flammable liquids, gases, or
vapors and of hazardous (classified) locations for electrical installations in
chemical process areas. And NFPA Code 499 is recommend practice for
classification of combustible dusts and of hazardous (classified) locations for
electrical installations in chemical process areas.

IEC 60079-10 provides rules and standards about how to define and develop
the extent of a Zone-classified area. Appendix C of IEC 60079 contains
examples demonstrating the results of the applications of the rules found in the
body of the IEC 60079 document.


Comparison
Both Division and Zone classification systems begin with defining what the
hazard is and the probability the hazard will be present.

Comparison of how the hazards are defined
The NEC Division system uses Classes and Groups to identify the hazard. The
classes are used to represent gases, types of dusts, or fibres.

   •   Class I represents flammable gases and vapours
   •   Class II represents combustible dusts,
   •   Class III represents ignitable fibres

Groups further define the hazard in Class I and II locations. For Class I, Groups
A (acetylene and similar gases), B (hydrogen and similar gases), C (ethylene
and similar gases), and D (propane and similar gases) represent flammable
gases.

The IEC Zone system identifies the hazard by two main Groups:
Group I for mining (underground locations) and Group II for surface (not
underground) industries. [Note: NEC doesn't cover underground mining
installations which are covered by the Mine Safety and Health Administration
(MSHA)].

Group II is divided into three subgroups arranged in order of hazard due to
threat of ignition: A (the most difficult to ignite, such as propane); B (gases such
as ethylene); and C (the easiest to ignite, such as acetylene/hydrogen).




www.intertek-hazloc.com
Hazardous locations:
                                                             EU & NA requirements




Divisions
A Class I Division 1 location is where:

   •   Concentrations (refer to NFPA 497) for the percentage volumes of gases
       that will burn, since too little (too lean) or too much (too rich) gas won't
       burn of flammable gases or vapours that would be ignitable under normal
       operating conditions,
   •   Hazardous gas mixture(s) may exist frequently because of repair or
       maintenance operations or leakage, or
   •   The breakdown of equipment simultaneously releases hazardous gas
       and causes failure of electrical equipment.

A Class I Division 2 location is where:

   •   Volatile flammable liquids are handled or stored, but they are normally
       confined within closed containers from which they can escape through
       container rupture, or
   •   Positive ventilation normally prevents ignitable concentrations of vapours
       (that is, the quantity of clean air continually brought into the atmosphere
       prevents the hazardous gas concentration from reaching its lower
       explosive limit percentage), or
   •   The area is adjacent to a Class I Division 1 location from which
       hazardous concentrations of gas may occasionally be transported.

IEC/CENELEC

The IEC/CENELEC approach uses three Zones instead of two Divisions. The
Zones are based on how often (frequency and duration) the hazard is present
instead of whether the hazard is present "normally."

IEC 60079-10, Electrical Apparatus for Explosive Gas Atmospheres,
Classification of Hazardous Areas. The definitions of zones are as follows:

   •   Zone 0 location is "...an area in which an explosive gas atmosphere is
       present continuously or for long periods."
   •   Zone 1 location is "...an area in which an explosive gas atmosphere is
       likely to occur in normal operation."
   •   Zone 2 location is "...an area in which an explosive gas atmosphere is
       not likely to occur in normal operation, and if it does occur, is likely to do
       so only infrequently and will exist for a short period only."

The zone system makes extensive use of the Lower Explosive Limit (LEL)
concept. That is, if the amount of flammable gas in the atmosphere mixture is
below the LEL for the gas, then the mixture is too lean and won't burn. However,

www.intertek-hazloc.com
Hazardous locations:
                                                              EU & NA requirements




the "...likely frequency of release, the release rate, the concentration, the
velocity, the ventilation, and other factors all affect the Zone classification."

The concept of Zone 0 is a big difference. Zone 1 locations are roughly
equivalent to Division 1 locations and Zone 2 locations roughly equivalent to
Division 2 locations.

Explosion Protection Concepts

One of the major problems in designing for both European and North American
systems are protection concepts availability, applicable standards, standards
harmonization and preferences. In North America allowable protection concepts
are defined in the National Electric Code (NEC) and Canadian Electric Code
(CEC). Under Article 500 of the NEC, the allowable protection techniques are:
Explosion proof (Flameproof in Europe), Dust Ignition proof, Dust tight, Intrinsic
Safety, Purged and Pressurized, Nonincendive, Oil Immersion, Hermetically
Sealed and Combustible Gas Detection System are allowed concepts for
Division 1 and/or 2 locations. While the NEC does recognize the Zone system
under Articles 505 and 506, a majority of the existing area classifications
throughout North America are classified under the Class and Division system.
The NEC does allow, on a limited basis, the use of Zone certified equipment to
be installed in Class and Division classified areas.

In Europe and in many other countries, commonly used concepts in addition to
the ones suitable for North America such as Increased Safety Ex ‘e’ (primarily
used for AC Motors, junction boxes and luminaries) and Encapsulation are
widely used, along with the lesser used concepts such as Oil Filled or Powder
Filled.

In addition, ATEX Certification requires that ‘all’ potential ignition sources are
addressed, including non-electrical sources such as friction, impact, static and
RF. Many additional protection concepts such as ‘c’; constructional safety or ‘b’;
control of ignition sources, adding additional complexity to skid or assembly
approvals.

The division system uses ”explosion proof[2]” flame path cooling in Division 1
and Division 2 locations; but, in the Zone system does not allow this
"flameproof" methodology in Zone 0.

For all practical purposes, the T-ratings for both systems are identical. The zone
system allows intrinsic safety with two fault conditions applied (ia), as the
division system permits, and a lesser form of intrinsic safety that is only safe
with one fault applied (ib).




www.intertek-hazloc.com
Hazardous locations:
                                                            EU & NA requirements




In both the division and zone system, purging and pressurizing is permitted in
all locations. The use of "increased safety" (Ex e) protection isn't recognized by
the Division system; but the Zone system permits its use in all but Zone 0
locations.

Encapsulation (Ex ma and Ex mb) isn't a recognized protection method in the
Division system; but the Zone system uses it frequently.

"Special Protection" (Ex s) is not recognized within the division system; but, the
Zone system allows a mechanism whereby apparatus and equipment can be
certified to be safe and workable in a given location, though it does not comply
with the other recognized forms of protection.

Equipment certified for use in a Zone 0 can also be installed in a Zone 1 or 2;
likewise equipment certified for use in Class I Div 1 can also be installed in
Class I Division 2 locations.

North America

In North America-Division, Class, and Group Categories:

Division I - There is a high probability of an explosive atmosphere in normal
operation. This can be for part of the time, up to all the time.

Division 2 - There is a low probability of an explosive atmosphere being present
during normal operation.

The North American class designations are:

Class I - Contains flammable gases or vapours in quantities large enough to
produce an explosion.
Class II - Is hazardous due to the presence of combustible dust in the air.
Class III - Contains easily ignitable fibres or flyings in the air. However, the
quantities of fibres and flyings suspended in the air are not likely to be large
enough to cause an explosion.

Group designations further define the types of gases, and dusts

Example of an American certification would be:

Class 1, Div I, Groups A, B and C; Div 2, Groups F and G




www.intertek-hazloc.com
Hazardous locations:
                                                                    EU & NA requirements




NEC System


                                      NEC


                  Class I:                              Class II:           Class III:
                  Gases                                  Dusts          Combustible
                                                                       Fl i    & Fib

     Div I               Div 2             Div I              Div 2


             Group A:            Group A           Group E:          Note: Group E
             Acetylene                              Metal            Div 1 only


             Group B:            Group B           Group F:            Group F
             Hydrogen                               Coal

             Group C:            Group C           Group G:            Group G
             Ethylene                               Grain

             Group D:            Group D
             Propane




www.intertek-hazloc.com
Hazardous locations:
                                                                          EU & NA requirements




IEC Zone System


                                      IEC

                   Group I                  Group II


                                Gas Sub

                                                Group IIA


                                                Group IIB


                                                Group IIC



Dust Zones

For identifying dust areas in Europe, zones 20, 21 and 22 have been introduced,
the definition of dust zones is similar to that for gas zone i.e. 0, 1 and 2.
[1]
  Categories not to be confused with categories used in the ATEX Directive 94/9/EC
[2]
  The North American terminology “Explosion proof” is known as flameproof in Europe and rest of the
world




Part 2: Ingress protection and Enclosure ratings

Ingress protection (IP) is commonly required for most protection concepts
in Europe, while in North America considers enclosure type ratings
(NEMA or Type) as well as IP ratings. In addition, Hazardous Area
equipment that may be located outdoors often requires a higher rating
than the protection concept specifies. When certifying a product for both
Europe and North America, it is important to understand the ‘highest’
specification that will be required and work to that design.

The division system maintains a listing of types of enclosures, such as Type 4,
or 7, 12, while in the Zone system this is known as the Ingress Protection (IP)
system. The IP system designates, by means of a number, the degree of
protection provided by an enclosure against solid objects. It also has a second

www.intertek-hazloc.com
Hazardous locations:
                                                              EU & NA requirements




number to designate the degree of protection provided by the enclosure against
water ingress. For example, an IP number of 54 would eliminate the possible
ingress of dust and protect against splashing water from any direction.

What are IP ratings?

IEC (International Electro technical Commission) Publication 60529
Classification of Degrees of Protection Provided by Enclosures provides a
system for specifying the enclosures of electrical equipment on the basis of the
degree of protection provided by the enclosure. IEC 60529 does not specify
degrees of protection against mechanical damage of equipment, risk of
explosions, or conditions such as moisture (produced for example by
condensation), corrosive vapours, fungus, or vermin.
The European standard is based on IEC529 which in Europe is EN 60529. This
standard was originally used for electrical enclosures, however under ATEX
94/9/EC which is implemented in the UK as the Equipment and Protective
System Regulations 1996, this now equally applies to non-electrical equipment.
Refer to the chapter on equipment marking for further details.

The Ingress Protection (IP) ratings are developed by the European Committee
for Electro Technical Standardization (CENELEC) and specify the
environmental protection an enclosure provides. The IP rating normally has two
(or three) numbers:

   1. Protection from solid objects or materials
   2. Protection from liquids
   3. Protection against mechanical impacts (commonly omitted)

The rating refers to the equipment's ability to permit solids and liquids to
penetrate the equipment enclosure. Electrical equipment’s IP rating is
expressed as a two-digit number. The first number designates protection from
solids, while the second number designates protection from liquids. It is
important that manufacturers have their equipment certified by an outside
laboratory to verify the product's IP rating. Epsilon is one such organisation
which can verify the equipments IP rating; there are other companies that
provide this service. The important thing is that the product is certified by an
outside organization. If IP ratings are specified on a product's data sheet, then
an approval certification number should also be included.

An "x" is used for one of the digits if there is only one class of protection; i.e.
IPX4 which addresses liquids only.




www.intertek-hazloc.com
Hazardous locations:
                                                          EU & NA requirements




First Digit

The first digit of the IP code indicates the degree that persons are protected
against contact with moving parts (other than smooth rotating shafts, etc.) and
the degree that equipment is protected against solid foreign bodies (dusts)
intruding into an equipment.

                 1st Digit - Protection against solids / dust
 IP                  Test                Comment
  0                                      No protection

                                         Protected against solid bodies
  1                                      greater than 50mm diameter. (e.g.
                                         accidental contact with the hand)


                                         Protected against solid bodies
  2                                      greater than 12.5mm diameter. (e.g.
                                         finger)


                                         Protected against solid bodies
  3                                      greater than 2.5mm diameter (e.g.
                                         tools, wires)


                                         Protected against solid bodies
  4                                      greater than 1.0mm diameter (e.g.
                                         thin tools and fine wire).


                                         Protected against dust (no harmful
  5                                      deposit)
                                         Dust Proof



                                         Completely protected against dusts
  6
                                         Dust Tight




www.intertek-hazloc.com
Hazardous locations:
                                                            EU & NA requirements




The table below shows the particle size used in the first digit of the IP rating, the
table is an accurate representation.

Table 1: Size chart

                                  IP2X=          IP3X=
       IP1X= 50mm                                           IP4X= 1mm      IP5= Dust
                                 12.5mm         2.5mm




                                                                  .             .




www.intertek-hazloc.com
Hazardous locations:
                                                          EU & NA requirements




Second Digit

The second digit indicates the degree of protection of the equipment inside the
enclosure against the harmful entry of water or moisture (e.g. dripping, spraying,
submersion, etc.)

               2nd Digit - Protection against water / moisture
 IP                  Test               Comment
  0                                     No protection

                                         Protected against vertically falling
  1
                                         drops of water (condensation)


                                         Protected against drops of water
  2
                                         falling up to 15° from the vertical


                                         Protected against water sprayed
  3
                                         up to 60° from the vertical


                                         Protected against splashing water
  4
                                         from all directions



                                         Protected against jets of water
  5
                                         from all directions


                                         Protected against powerful jets of
  6
                                         water from all directions


                                         Protected against the effects of
  7
                                         temporary immersion in water

                                         Protected against the continuous
                                         effects of immersion in water
  8
                                         having regard to specific
                                         conditions

www.intertek-hazloc.com
Hazardous locations:
                                                            EU & NA requirements




North American Enclosure Type Rating (NEMA)

The American form of Enclosure rating is known as NEMA or Type. NEMA is an
acronym for National Electrical Manufacturers Association.

Standards covering environmental considerations for electrical enclosures are
UL 50E, CSA C22.2 No. 94.2 and NEMA 250. NEMA Standard No. 250
provides the following information. NEMA Standards Publication 250 does test
for environmental conditions such as corrosion, rust, icing, oil, and coolants. For
this reason, and because the tests and evaluations for other characteristics are
not identical, the IEC Enclosure Classification Designations cannot be exactly
equated with NEMA Enclosure Type Numbers.

The definitions for each type of enclosure are given below:

Type 1: Enclosures are constructed for indoor use to provide a degree of
protection to personnel against access to hazardous parts and to provide a
degree of protection of the equipment inside the enclosure against ingress of
solid foreign objects (falling dirt).

Type 2: Enclosures are constructed for indoor use to provide a degree of
protection to personnel against access to hazardous parts; to provide a degree
of protection of the equipment inside the enclosure against ingress of solid
foreign objects (falling dirt); and to provide a degree of protection with respect to
harmful effects on the equipment due to the ingress of water (dripping and light
splashing).

Type 3: Enclosures are constructed for either indoor or outdoor use to provide a
degree of protection to personnel against access to hazardous parts; to provide
a degree of protection of the equipment inside the enclosure against ingress of
solid foreign objects (falling dirt and windblown dust); to provide a degree of
protection with respect to harmful effects on the equipment due to the ingress of
water (rain, sleet, snow); and that will be undamaged by the external formation
of ice on the enclosure.

Type 3R: Enclosures are constructed for either indoor or outdoor use to provide
a degree of protection to personnel against access to hazardous parts; to
provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt); to provide a degree of protection
with respect to harmful effects on the equipment due to the ingress of water
(rain, sleet, snow); and that will be undamaged by the external formation of ice
on the enclosure.

Type 3S: Enclosures are constructed for either indoor or outdoor use to provide
a degree of protection to personnel against access to hazardous parts; to


www.intertek-hazloc.com
Hazardous locations:
                                                           EU & NA requirements




provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt and windblown dust); to provide a
degree of protection with respect to harmful effects on the equipment due to the
ingress of water (rain, sleet, snow); and for which the external mechanism(s)
remain operable when ice laden.

Type 3X: Enclosures are constructed for either indoor or outdoor use to provide
a degree of protection to personnel against access to hazardous parts; to
provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt and windblown dust); to provide a
degree of protection with respect to harmful effects on the equipment due to the
ingress of water (rain, sleet, snow); that provides an additional level of
protection against corrosion and that will be undamaged by the external
formation of ice on the enclosure.

Type 3RX: Enclosures are constructed for either indoor or outdoor use to
provide a degree of protection to personnel against access to hazardous parts;
to provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt); to provide a degree of protection
with respect to harmful effects on the equipment due to the ingress of water
(rain, sleet, snow); that will be undamaged by the external formation of ice on
the enclosure that provides an additional level of protection against corrosion;
and that will be undamaged by the external formation of ice on the enclosure.

Type 3SX: Enclosures are constructed for either indoor or outdoor use to
provide a degree of protection to personnel against access to hazardous parts;
to provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt and windblown dust); to provide a
degree of protection with respect to harmful effects on the equipment due to the
ingress of water (rain, sleet, snow); that provides an additional level of
protection against corrosion; and for which the external mechanism(s) remain
operable when ice laden.

Type 4: Enclosures are constructed for either indoor or outdoor use to provide a
degree of protection to personnel against access to hazardous parts; to provide
a degree of protection of the equipment inside the enclosure against ingress of
solid foreign objects (falling dirt and windblown dust); to provide a degree of
protection with respect to harmful effects on the equipment due to the ingress of
water (rain, sleet, snow, splashing water, and hose directed water); and that will
be undamaged by the external formation of ice on the enclosure.

Type 4X: Enclosures are constructed for either indoor or outdoor use to provide
a degree of protection to personnel against access to hazardous parts; to
provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (windblown dust); to provide a degree of


www.intertek-hazloc.com
Hazardous locations:
                                                              EU & NA requirements




protection with respect to harmful effects on the equipment due to the ingress of
water (rain, sleet, snow, splashing water, and hose directed water); that
provides an additional level of protection against corrosion; and that will be
undamaged by the external formation of ice on the enclosure.

Type 5: Enclosures are constructed for indoor use to provide a degree of
protection to personnel against access to hazardous parts; to provide a degree
of protection of the equipment inside the enclosure against ingress of solid
foreign objects (falling dirt and settling airborne dust, lint, fibres, and flyings);
and to provide a degree of protection with respect to harmful effects on the
equipment due to the ingress of water (dripping and light splashing).

Type 6: Enclosures are constructed for either indoor or outdoor use to provide a
degree of protection to personnel against access to hazardous parts; to provide
a degree of protection of the equipment inside the enclosure against ingress of
solid foreign objects (falling dirt); to provide a degree of protection with respect
to harmful effects on the equipment due to the ingress of water (hose directed
water and the entry of water during occasional temporary submersion at a
limited depth); and that will be undamaged by the external formation of ice on
the enclosure.

Type 6P: Enclosures are constructed for either indoor or outdoor use to provide
a degree of protection to personnel against access to hazardous parts; to
provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt); to provide a degree of protection
with respect to harmful effects on the equipment due to the ingress of water
(hose directed water and the entry of water during prolonged submersion at a
limited depth); that provides an additional level of protection against corrosion
and that will be undamaged by the external formation of ice on the enclosure.

Type 12: Enclosures are constructed (without knockouts) for indoor use to
provide a degree of protection to personnel against access to hazardous parts;
to provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt and circulating dust, lint, fibres, and
flyings); and to provide a degree of protection with respect to harmful effects on
the equipment due to the ingress of water (dripping and light splashing).

Type 12K: Enclosures are constructed (with knockouts) for indoor use to
provide a degree of protection to personnel against access to hazardous parts;
to provide a degree of protection of the equipment inside the enclosure against
ingress of solid foreign objects (falling dirt and circulating dust, lint, fibres, and
flyings); and to provide a degree of protection with respect to harmful effects on
the equipment due to the ingress of water (dripping and light splashing).




www.intertek-hazloc.com
Hazardous locations:
                                                           EU & NA requirements




Type 13: Enclosures are constructed for indoor use to provide a degree of
protection to personnel against access to hazardous parts; to provide a degree
of protection of the equipment inside the enclosure against ingress of solid
foreign objects (falling dirt and circulating dust, lint, fibres, and flyings); to
provide a degree of protection against harmful effects on the equipment due to
the ingress of water (dripping and light splashing); and to provide protection
against spraying, splashing, and seepage of oil and non-corrosive coolants.

The following table provides a guide for converting from NEMA enclosure type
numbers to IP rating. The NEMA Types meet or exceed the test requirements
for the associated IEC Classifications; for this reason, the table should not be
used to convert from IP rating to NEMA.

                                                                            IP
NEMA     Application         Comment
                                                                        Equivalent
                             Protected against accidental contact,
   1     Indoors                                                            IP20
                             limited amount of dirt
   2     Indoors             Intrusion of dripping water and dirt
                             Protection against dust, rain. No
   3     Outdoors                                                           IP64
                             damage when ice forms on housing
                             Protection against rain. No damage
  3R     Outdoors                                                           IP22
                             when ice forms on the housing
                             Protection against dust, rain and hail.
  3S     Outdoors            No damage when ice forms on the                IP64
                             housing
                             Protection against splash water, dust,
   4     Indoors/Outdoors    rain. No damage when ice forms on              IP66
                             the housing
                             Protection against splash water, dust,
                             rain. No damage when ice forms on
  4X     Indoors/Outdoors                                                   IP66
                             the     housing.    Protected    against
                             corrosion
                             Protection against dust, water jet and
                             water during temporary submersion.
   6     Indoors/Outdoors                                                   IP67
                             No damage when ice forms on the
                             housing
                             Protection against water during longer
  6P     Indoors/Outdoors    submersion. Protected against
                             corrosion
                             Protection against dripping water.
  11     Indoors
                             Protected against corrosion
 12,                         Protected against dust and dripping
         Indoors                                                            IP55
 12K                         water
                             Protected against dust and splash
  13     Indoors                                                            IP65
                             water, oil and non-corrosive liquids


www.intertek-hazloc.com
Hazardous locations:
                                                                                       EU & NA requirements




For more information on Intertek’s services for hazardous location product testing, site
assessment and technical training capabilities or to begin your project right away,



                                        Call: 1-800-WORLDLAB
                         Email: icenter@intertek.com, info.uk@intertek.com
                                  or visit: www.intertek-hazloc.com




Our Hazardous Location Credentials
Intertek has one of the largest and most experienced hazardous location teams available at multiple
locations world-wide. Our expertise is backed by a number of accreditations and recognitions
including:

     •    OSHA recognized Nationally Recognized Testing Laboratory (NRTL) for Hazardous
          Location Divisional Listing
     •    Standards Council of Canada accredited Certification Body (CB) and Testing Organization
          (TO)
     •    Notified Body and UKAS Accredited for the ATEX Directive, 94/9/EC.
     •    IECEx Certification Body (CB) and Test Laboratory (TL)
     •    Full Hazloc Training including an Accredited COMPEX Training Center
     •    Site Services (Risk Assessment, Area Classification and Inspection)

We certify products for compliance to National and International published standards which satisfy
the applicable requirements of the National Electrical Code (NEC) in the U.S., the Canadian
Electrical Code (CEC) in Canada, IECEX and the European Union's ATEX Directive. Some of the
standards we test to include those of ANSI, UL, IEC, CSA, MIL Specs, FM, and CENELEC and CEN.




This publication is copyright Š Intertek and may not be reproduced or transmitted in any form in whole or in part without
the prior written permission of Intertek. While due care has been taken during the preparation of this document, Intertek
cannot be held responsible for the accuracy of the information herein or for any consequence arising from it. Clients are
encouraged to seek Intertek’s current advice on their specific needs before acting upon any of the content.




www.intertek-hazloc.com

More Related Content

Viewers also liked

RSPCA - All About Cottage Holidays
RSPCA - All About Cottage HolidaysRSPCA - All About Cottage Holidays
RSPCA - All About Cottage HolidaysRSPCA
 
Story board cj
Story board cjStory board cj
Story board cjMatt Stephens
 
01 helping business owners leverage linked in for profitable business growth
01 helping business owners leverage linked in for profitable business growth01 helping business owners leverage linked in for profitable business growth
01 helping business owners leverage linked in for profitable business growthDr. Mark D. Yates
 
PRODUCTS & SERVICES
PRODUCTS & SERVICESPRODUCTS & SERVICES
PRODUCTS & SERVICESShylacss
 
Thabo Tabane's CV
Thabo Tabane's CVThabo Tabane's CV
Thabo Tabane's CVThabo Tabane
 
Presentatie Qfever
Presentatie QfeverPresentatie Qfever
Presentatie QfeverViruskenner
 
Q koorts presentatie Viruskenner 2011
Q koorts presentatie Viruskenner 2011Q koorts presentatie Viruskenner 2011
Q koorts presentatie Viruskenner 2011Viruskenner
 
Barefoot Mailman Special Event
Barefoot Mailman Special EventBarefoot Mailman Special Event
Barefoot Mailman Special Eventchristinedirocco
 
The moving shoelace
The moving shoelaceThe moving shoelace
The moving shoelaceMatt Stephens
 
An toan lao dong - THẢO NGUYÊN XANH GROUP
An toan lao dong - THẢO NGUYÊN XANH GROUPAn toan lao dong - THẢO NGUYÊN XANH GROUP
An toan lao dong - THẢO NGUYÊN XANH GROUPThaoNguyenXanh2
 
20110916 social business agenda
20110916 social business agenda20110916 social business agenda
20110916 social business agendaFlĂĄvio Mendes
 
Energy market biofuels
Energy market   biofuelsEnergy market   biofuels
Energy market biofuelsTomasz Miotk
 
Er p directive-televisions
Er p directive-televisionsEr p directive-televisions
Er p directive-televisionsIntertek CE
 
Wp eu p_lighting
Wp eu p_lightingWp eu p_lighting
Wp eu p_lightingIntertek CE
 
Overview of Characteristics and Issues Related to Economic Development in Por...
Overview of Characteristics and Issues Related to Economic Development in Por...Overview of Characteristics and Issues Related to Economic Development in Por...
Overview of Characteristics and Issues Related to Economic Development in Por...Caitlyn Horose
 

Viewers also liked (17)

RSPCA - All About Cottage Holidays
RSPCA - All About Cottage HolidaysRSPCA - All About Cottage Holidays
RSPCA - All About Cottage Holidays
 
Story board cj
Story board cjStory board cj
Story board cj
 
01 helping business owners leverage linked in for profitable business growth
01 helping business owners leverage linked in for profitable business growth01 helping business owners leverage linked in for profitable business growth
01 helping business owners leverage linked in for profitable business growth
 
PRODUCTS & SERVICES
PRODUCTS & SERVICESPRODUCTS & SERVICES
PRODUCTS & SERVICES
 
Thabo Tabane's CV
Thabo Tabane's CVThabo Tabane's CV
Thabo Tabane's CV
 
Presentatie Qfever
Presentatie QfeverPresentatie Qfever
Presentatie Qfever
 
Q koorts presentatie Viruskenner 2011
Q koorts presentatie Viruskenner 2011Q koorts presentatie Viruskenner 2011
Q koorts presentatie Viruskenner 2011
 
Barefoot Mailman Special Event
Barefoot Mailman Special EventBarefoot Mailman Special Event
Barefoot Mailman Special Event
 
The moving shoelace
The moving shoelaceThe moving shoelace
The moving shoelace
 
Btc book titles 12
Btc book titles 12Btc book titles 12
Btc book titles 12
 
An toan lao dong - THẢO NGUYÊN XANH GROUP
An toan lao dong - THẢO NGUYÊN XANH GROUPAn toan lao dong - THẢO NGUYÊN XANH GROUP
An toan lao dong - THẢO NGUYÊN XANH GROUP
 
20110916 social business agenda
20110916 social business agenda20110916 social business agenda
20110916 social business agenda
 
Energy market biofuels
Energy market   biofuelsEnergy market   biofuels
Energy market biofuels
 
Er p directive-televisions
Er p directive-televisionsEr p directive-televisions
Er p directive-televisions
 
31 sipapu
31 sipapu31 sipapu
31 sipapu
 
Wp eu p_lighting
Wp eu p_lightingWp eu p_lighting
Wp eu p_lighting
 
Overview of Characteristics and Issues Related to Economic Development in Por...
Overview of Characteristics and Issues Related to Economic Development in Por...Overview of Characteristics and Issues Related to Economic Development in Por...
Overview of Characteristics and Issues Related to Economic Development in Por...
 

Similar to E uv usexplosiveareas

A_Basics_of_Explosion_Protection_HAZARDO.pdf
A_Basics_of_Explosion_Protection_HAZARDO.pdfA_Basics_of_Explosion_Protection_HAZARDO.pdf
A_Basics_of_Explosion_Protection_HAZARDO.pdfHedi Ben Mohamed
 
Technor - Explosion Proof, Hazardous Area Control Panels
Technor - Explosion Proof, Hazardous Area Control PanelsTechnor - Explosion Proof, Hazardous Area Control Panels
Technor - Explosion Proof, Hazardous Area Control PanelsThorne & Derrick International
 
Explosion protection theory and practice
Explosion protection   theory and practiceExplosion protection   theory and practice
Explosion protection theory and practiceDavid Pires
 
Thomas & Betts - Hazardous Area Electrical Equipment & Cable Accessories
Thomas & Betts - Hazardous Area Electrical Equipment & Cable AccessoriesThomas & Betts - Hazardous Area Electrical Equipment & Cable Accessories
Thomas & Betts - Hazardous Area Electrical Equipment & Cable AccessoriesThorne & Derrick International
 
Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...
Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...
Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...Thorne & Derrick International
 
Hazardous area classification and control of ignition sources
Hazardous area classification and control of ignition sourcesHazardous area classification and control of ignition sources
Hazardous area classification and control of ignition sourceseldhoev
 
Guide to hazardous_areas
Guide to hazardous_areasGuide to hazardous_areas
Guide to hazardous_areasDanny Yuana
 
Nilfisk Industrial Vacuum Solutions - ATEX and safety
Nilfisk Industrial Vacuum Solutions - ATEX and safetyNilfisk Industrial Vacuum Solutions - ATEX and safety
Nilfisk Industrial Vacuum Solutions - ATEX and safetyNilfiskIndustrialVacuumSolutions
 
Explosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous AreasExplosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous AreasThorne & Derrick UK
 
Asco solenoid valve temperature code explanation whitepaper
Asco solenoid valve temperature code explanation whitepaperAsco solenoid valve temperature code explanation whitepaper
Asco solenoid valve temperature code explanation whitepaperClassic Controls, Inc.
 
internship2015
internship2015internship2015
internship2015Husnain Bilal
 
Hazloc overview
Hazloc overviewHazloc overview
Hazloc overviewJohn Kingsley
 
A Guide to Safe Electronic Weighing in Hazardous Locations
A Guide to Safe Electronic Weighing in Hazardous LocationsA Guide to Safe Electronic Weighing in Hazardous Locations
A Guide to Safe Electronic Weighing in Hazardous LocationsPower Specialties, Inc.
 
Hazardous Locations 101 by Pepperl+Fuchs
Hazardous Locations 101 by Pepperl+FuchsHazardous Locations 101 by Pepperl+Fuchs
Hazardous Locations 101 by Pepperl+FuchsKristen_Barbour_PF
 
Flexicon Flexible Conduit - Hazardous Areas ATEX Conduit Catalogue
Flexicon Flexible Conduit - Hazardous Areas ATEX Conduit CatalogueFlexicon Flexible Conduit - Hazardous Areas ATEX Conduit Catalogue
Flexicon Flexible Conduit - Hazardous Areas ATEX Conduit CatalogueThorne & Derrick International
 
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...Thorne & Derrick International
 
Straightpoint ATEX & IECEx load monitoring products for hazardous areas
Straightpoint ATEX & IECEx load monitoring products for hazardous areasStraightpoint ATEX & IECEx load monitoring products for hazardous areas
Straightpoint ATEX & IECEx load monitoring products for hazardous areasDavid Mullard
 
HAC - Hazardous Area Classification
HAC - Hazardous Area ClassificationHAC - Hazardous Area Classification
HAC - Hazardous Area ClassificationHarkishan Prajapati
 

Similar to E uv usexplosiveareas (20)

A_Basics_of_Explosion_Protection_HAZARDO.pdf
A_Basics_of_Explosion_Protection_HAZARDO.pdfA_Basics_of_Explosion_Protection_HAZARDO.pdf
A_Basics_of_Explosion_Protection_HAZARDO.pdf
 
Technor - Explosion Proof, Hazardous Area Control Panels
Technor - Explosion Proof, Hazardous Area Control PanelsTechnor - Explosion Proof, Hazardous Area Control Panels
Technor - Explosion Proof, Hazardous Area Control Panels
 
Explosion protection theory and practice
Explosion protection   theory and practiceExplosion protection   theory and practice
Explosion protection theory and practice
 
Thomas & Betts - Hazardous Area Electrical Equipment & Cable Accessories
Thomas & Betts - Hazardous Area Electrical Equipment & Cable AccessoriesThomas & Betts - Hazardous Area Electrical Equipment & Cable Accessories
Thomas & Betts - Hazardous Area Electrical Equipment & Cable Accessories
 
Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...
Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...
Thomas & Betts Kopex - Understanding Hazardous Areas & Specifying Flexible Co...
 
Hazardous area classification and control of ignition sources
Hazardous area classification and control of ignition sourcesHazardous area classification and control of ignition sources
Hazardous area classification and control of ignition sources
 
Is.5572.2009
Is.5572.2009Is.5572.2009
Is.5572.2009
 
Guide to hazardous_areas
Guide to hazardous_areasGuide to hazardous_areas
Guide to hazardous_areas
 
Nilfisk Industrial Vacuum Solutions - ATEX and safety
Nilfisk Industrial Vacuum Solutions - ATEX and safetyNilfisk Industrial Vacuum Solutions - ATEX and safety
Nilfisk Industrial Vacuum Solutions - ATEX and safety
 
Explosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous AreasExplosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous Areas
 
Asco solenoid valve temperature code explanation whitepaper
Asco solenoid valve temperature code explanation whitepaperAsco solenoid valve temperature code explanation whitepaper
Asco solenoid valve temperature code explanation whitepaper
 
internship2015
internship2015internship2015
internship2015
 
Hazloc overview
Hazloc overviewHazloc overview
Hazloc overview
 
A Guide to Safe Electronic Weighing in Hazardous Locations
A Guide to Safe Electronic Weighing in Hazardous LocationsA Guide to Safe Electronic Weighing in Hazardous Locations
A Guide to Safe Electronic Weighing in Hazardous Locations
 
Hazardous Locations 101 by Pepperl+Fuchs
Hazardous Locations 101 by Pepperl+FuchsHazardous Locations 101 by Pepperl+Fuchs
Hazardous Locations 101 by Pepperl+Fuchs
 
Flexicon Flexible Conduit - Hazardous Areas ATEX Conduit Catalogue
Flexicon Flexible Conduit - Hazardous Areas ATEX Conduit CatalogueFlexicon Flexible Conduit - Hazardous Areas ATEX Conduit Catalogue
Flexicon Flexible Conduit - Hazardous Areas ATEX Conduit Catalogue
 
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
 
FIRE_Safety.pptx
FIRE_Safety.pptxFIRE_Safety.pptx
FIRE_Safety.pptx
 
Straightpoint ATEX & IECEx load monitoring products for hazardous areas
Straightpoint ATEX & IECEx load monitoring products for hazardous areasStraightpoint ATEX & IECEx load monitoring products for hazardous areas
Straightpoint ATEX & IECEx load monitoring products for hazardous areas
 
HAC - Hazardous Area Classification
HAC - Hazardous Area ClassificationHAC - Hazardous Area Classification
HAC - Hazardous Area Classification
 

More from Intertek CE

CE Presentation
CE Presentation CE Presentation
CE Presentation Intertek CE
 
EMC Testing brochure
EMC Testing brochureEMC Testing brochure
EMC Testing brochureIntertek CE
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilitiesIntertek CE
 
Emc testing-brochure
Emc testing-brochureEmc testing-brochure
Emc testing-brochureIntertek CE
 
ETL Mark Fact-sheet
ETL Mark Fact-sheetETL Mark Fact-sheet
ETL Mark Fact-sheetIntertek CE
 
Hvac single-sheet-brochure
Hvac single-sheet-brochureHvac single-sheet-brochure
Hvac single-sheet-brochureIntertek CE
 
Hvac brochure
Hvac brochureHvac brochure
Hvac brochureIntertek CE
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilitiesIntertek CE
 
Intertek gs en
Intertek gs enIntertek gs en
Intertek gs enIntertek CE
 
Etl vs-ul-chart
Etl vs-ul-chartEtl vs-ul-chart
Etl vs-ul-chartIntertek CE
 
Eu p power_supplies_im_final
Eu p power_supplies_im_finalEu p power_supplies_im_final
Eu p power_supplies_im_finalIntertek CE
 
Ems pre reg_tips
Ems pre reg_tipsEms pre reg_tips
Ems pre reg_tipsIntertek CE
 
Emc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsEmc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsIntertek CE
 
Emc safety
Emc safetyEmc safety
Emc safetyIntertek CE
 
Effects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsEffects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsIntertek CE
 
Eco design directive
Eco design directiveEco design directive
Eco design directiveIntertek CE
 
Door testing 10_steps
Door testing 10_stepsDoor testing 10_steps
Door testing 10_stepsIntertek CE
 
Doing business-with-the-government
Doing business-with-the-governmentDoing business-with-the-government
Doing business-with-the-governmentIntertek CE
 

More from Intertek CE (20)

CE Presentation
CE Presentation CE Presentation
CE Presentation
 
EMC Testing brochure
EMC Testing brochureEMC Testing brochure
EMC Testing brochure
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilities
 
Emc testing-brochure
Emc testing-brochureEmc testing-brochure
Emc testing-brochure
 
ETL Mark Fact-sheet
ETL Mark Fact-sheetETL Mark Fact-sheet
ETL Mark Fact-sheet
 
Hvac single-sheet-brochure
Hvac single-sheet-brochureHvac single-sheet-brochure
Hvac single-sheet-brochure
 
Hvac brochure
Hvac brochureHvac brochure
Hvac brochure
 
Intertek emc capabilities
Intertek emc capabilitiesIntertek emc capabilities
Intertek emc capabilities
 
S mark-en
S mark-enS mark-en
S mark-en
 
Intertek gs en
Intertek gs enIntertek gs en
Intertek gs en
 
Etl vs-ul-chart
Etl vs-ul-chartEtl vs-ul-chart
Etl vs-ul-chart
 
Wh mark
Wh markWh mark
Wh mark
 
Eu p power_supplies_im_final
Eu p power_supplies_im_finalEu p power_supplies_im_final
Eu p power_supplies_im_final
 
Ems pre reg_tips
Ems pre reg_tipsEms pre reg_tips
Ems pre reg_tips
 
Emc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systemsEmc compliance-for-renewable-resource-power-systems
Emc compliance-for-renewable-resource-power-systems
 
Emc safety
Emc safetyEmc safety
Emc safety
 
Effects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designsEffects of emc_on_smart_appliance_designs
Effects of emc_on_smart_appliance_designs
 
Eco design directive
Eco design directiveEco design directive
Eco design directive
 
Door testing 10_steps
Door testing 10_stepsDoor testing 10_steps
Door testing 10_steps
 
Doing business-with-the-government
Doing business-with-the-governmentDoing business-with-the-government
Doing business-with-the-government
 

Recently uploaded

Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessSeta Wicaksana
 
Kenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith PereraKenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith Pereraictsugar
 
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxContemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxMarkAnthonyAurellano
 
Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Kirill Klimov
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?Olivia Kresic
 
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCRashishs7044
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadAyesha Khan
 
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City GurgaonCall Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaoncallgirls2057
 
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menzaictsugar
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607dollysharma2066
 
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdfNewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdfKhaled Al Awadi
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCRashishs7044
 
Future Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted VersionFuture Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted VersionMintel Group
 
International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...ssuserf63bd7
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfrichard876048
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...lizamodels9
 
Kenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby AfricaKenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby Africaictsugar
 

Recently uploaded (20)

Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful Business
 
Kenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith PereraKenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith Perera
 
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptxContemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
Contemporary Economic Issues Facing the Filipino Entrepreneur (1).pptx
 
Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?
 
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
 
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City GurgaonCall Us 📲8800102216📞 Call Girls In DLF City Gurgaon
Call Us 📲8800102216📞 Call Girls In DLF City Gurgaon
 
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
 
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdfNewBase  19 April  2024  Energy News issue - 1717 by Khaled Al Awadi.pdf
NewBase 19 April 2024 Energy News issue - 1717 by Khaled Al Awadi.pdf
 
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
8447779800, Low rate Call girls in New Ashok Nagar Delhi NCR
 
Future Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted VersionFuture Of Sample Report 2024 | Redacted Version
Future Of Sample Report 2024 | Redacted Version
 
International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...International Business Environments and Operations 16th Global Edition test b...
International Business Environments and Operations 16th Global Edition test b...
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdf
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
 
Kenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby AfricaKenya’s Coconut Value Chain by Gatsby Africa
Kenya’s Coconut Value Chain by Gatsby Africa
 

E uv usexplosiveareas

  • 1. Potentially Explosive Atmospheres Requirements Understand the differences between European and North American rules Intertek 1-800-WORLDLAB icenter@intertek.com www.intertek-hazloc.com
  • 2. Hazardous locations: EU & NA requirements Overview The Explosive Atmospheres market is both lucrative and expanding, but the level of certification requirements and the level of checking (both by the buyer and by the regulatory authorities) are increasing. In order to access this market it is imperative that equipment manufacturers understand the design, manufacture and certification requirements on both discrete apparatus and assemblies (rigs and skids) to ensure that the products are designed without adding unnecessary costs and that the products are certified on time and correctly. To facilitate this, Intertek can help with design advice, training and complete global certification at multiple locations worldwide. Introduction What is Potentially Explosive Atmosphere Certification and why might you need it? Any industry that processes, uses or manufactures materials that may give rise to a flammable atmosphere (gas, mist, liquid, dusts or even small fibres) may have a potentially explosive atmosphere. Such industries/processes include: • Oil and Gas Drilling • Petrochemical Refining and Processing • Fuel Storage • Chemical manufacturing • Car Manufacturing • Water Treatment • Power Generation • Pharmaceutical • Distilleries • Food manufacturers • Aviation • Military www.intertek-hazloc.com
  • 3. Hazardous locations: EU & NA requirements Where fuel and oxygen (normally the oxygen in air) are present in the workplace, potential ignition sources must be rendered safe to an acceptable level for the risk. Industries that generate potentially explosive atmospheres classify the dangerous areas based on the likelihood and duration of the explosive atmospheres presence. This is referred to as a ‘Zone’ (Europe and NEC505) or ‘Division’ (NEC500). When a Zone or Division has been established, special precautions must be taken by the manufacturer to reduce the likelihood of an ignition being present to an acceptable level (and possibly to use mitigation measures to lower the consequence of an explosion). Given the onerous nature of an explosion, special certification schemes have been set up to control the design and certification of equipment for potentially explosive atmospheres. Although the schemes differ globally (some are mandatory under law, some are simply procurement specifications), the bases for design and certification is similar, and the schemes normally rely on empirical testing, constructional assessment and production control by a recognised Certification Body. Manufacturers of electrical equipment (and non-electrical for Europe) must be aware that if they sell to industries that have potentially explosive atmospheres (the vast majority of industries) they may be asked for ‘certification’, and that often the equipment will need to be certified by a Notified or NRTL Body such as Intertek. www.intertek-hazloc.com
  • 4. Hazardous locations: EU & NA requirements Part 1: Zones & Divisions What are the differences between the Zone and Division systems in hazardous (classified) locations? What do the terms Zone and Division mean and what are their similarities and differences? The aim of both is to achieve safety by identifying areas where ignition sources should be eliminated or ensuring that the ignition source is non-effective. Until the advent of ATEX in July 2003, the most prevalent ignition sources where those associated with electrical equipment e.g. electrical arcing or electrically heated surfaces. Both systems work with the same natural laws of physics and chemistry, such as gas ignition temperatures and combustible percentages of volatile gases. In 1947, the NEC first recognized different levels of risk exist in hazardous locations. Consequently, it established Division 1 and Division 2, to provide a means to treat the issue. This permitted installation methods to be specified, based upon what was considered to be an acceptable level of risk. The IEC recognized the NEC divisions were based more on whether the hazard was present under either normal or abnormal conditions, instead of on the duration of the hazard. Therefore, the IEC established three divisions, or Zones, that are based on how often the hazard is present rather than upon normal versus abnormal conditions. The three zones break the NEC's Division 1 into two distinct zones, one of which (Zone 0) is for those locations that are the most hazardous because they remain hazardous for a long time. Separating Zone 0 from the remainder of what is Division 1 in the NEC system permits a more refined treatment of the hazards of the two zones. It restricts methods of protection in Zone 0 while permitting more relaxed method of protection in Zone 1 locations. The NEC Committee rewrote Article 505 because the Division Classification system and IEC system are too different to merge. The IEC and NEC Group classifications for the different gases in ascending order of "More Easily Ignitable." Note that the group denoted with an "A" in the IEC area is the least ignitable, while the group denoted with an "A" in the NEC group is the most ignitable. Also, the IEC system uses three sub-groups for the representative gases while the NEC system uses four. To further confuse the two systems, the IEC and NEC do not use the same terminology, and neither have the same number of categories [1] (zones) to identify the likelihood of the hazard being present. Standards The American Petroleum Institute (API) RP 500, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities www.intertek-hazloc.com
  • 5. Hazardous locations: EU & NA requirements Classified as Class I Division I and Division 2, defines the extent of classified areas in refineries operating under the Division system. The National Fire Protection Association (NFPA) published NFPA Codes 497 recommended practice for the classification of flammable liquids, gases, or vapors and of hazardous (classified) locations for electrical installations in chemical process areas. And NFPA Code 499 is recommend practice for classification of combustible dusts and of hazardous (classified) locations for electrical installations in chemical process areas. IEC 60079-10 provides rules and standards about how to define and develop the extent of a Zone-classified area. Appendix C of IEC 60079 contains examples demonstrating the results of the applications of the rules found in the body of the IEC 60079 document. Comparison Both Division and Zone classification systems begin with defining what the hazard is and the probability the hazard will be present. Comparison of how the hazards are defined The NEC Division system uses Classes and Groups to identify the hazard. The classes are used to represent gases, types of dusts, or fibres. • Class I represents flammable gases and vapours • Class II represents combustible dusts, • Class III represents ignitable fibres Groups further define the hazard in Class I and II locations. For Class I, Groups A (acetylene and similar gases), B (hydrogen and similar gases), C (ethylene and similar gases), and D (propane and similar gases) represent flammable gases. The IEC Zone system identifies the hazard by two main Groups: Group I for mining (underground locations) and Group II for surface (not underground) industries. [Note: NEC doesn't cover underground mining installations which are covered by the Mine Safety and Health Administration (MSHA)]. Group II is divided into three subgroups arranged in order of hazard due to threat of ignition: A (the most difficult to ignite, such as propane); B (gases such as ethylene); and C (the easiest to ignite, such as acetylene/hydrogen). www.intertek-hazloc.com
  • 6. Hazardous locations: EU & NA requirements Divisions A Class I Division 1 location is where: • Concentrations (refer to NFPA 497) for the percentage volumes of gases that will burn, since too little (too lean) or too much (too rich) gas won't burn of flammable gases or vapours that would be ignitable under normal operating conditions, • Hazardous gas mixture(s) may exist frequently because of repair or maintenance operations or leakage, or • The breakdown of equipment simultaneously releases hazardous gas and causes failure of electrical equipment. A Class I Division 2 location is where: • Volatile flammable liquids are handled or stored, but they are normally confined within closed containers from which they can escape through container rupture, or • Positive ventilation normally prevents ignitable concentrations of vapours (that is, the quantity of clean air continually brought into the atmosphere prevents the hazardous gas concentration from reaching its lower explosive limit percentage), or • The area is adjacent to a Class I Division 1 location from which hazardous concentrations of gas may occasionally be transported. IEC/CENELEC The IEC/CENELEC approach uses three Zones instead of two Divisions. The Zones are based on how often (frequency and duration) the hazard is present instead of whether the hazard is present "normally." IEC 60079-10, Electrical Apparatus for Explosive Gas Atmospheres, Classification of Hazardous Areas. The definitions of zones are as follows: • Zone 0 location is "...an area in which an explosive gas atmosphere is present continuously or for long periods." • Zone 1 location is "...an area in which an explosive gas atmosphere is likely to occur in normal operation." • Zone 2 location is "...an area in which an explosive gas atmosphere is not likely to occur in normal operation, and if it does occur, is likely to do so only infrequently and will exist for a short period only." The zone system makes extensive use of the Lower Explosive Limit (LEL) concept. That is, if the amount of flammable gas in the atmosphere mixture is below the LEL for the gas, then the mixture is too lean and won't burn. However, www.intertek-hazloc.com
  • 7. Hazardous locations: EU & NA requirements the "...likely frequency of release, the release rate, the concentration, the velocity, the ventilation, and other factors all affect the Zone classification." The concept of Zone 0 is a big difference. Zone 1 locations are roughly equivalent to Division 1 locations and Zone 2 locations roughly equivalent to Division 2 locations. Explosion Protection Concepts One of the major problems in designing for both European and North American systems are protection concepts availability, applicable standards, standards harmonization and preferences. In North America allowable protection concepts are defined in the National Electric Code (NEC) and Canadian Electric Code (CEC). Under Article 500 of the NEC, the allowable protection techniques are: Explosion proof (Flameproof in Europe), Dust Ignition proof, Dust tight, Intrinsic Safety, Purged and Pressurized, Nonincendive, Oil Immersion, Hermetically Sealed and Combustible Gas Detection System are allowed concepts for Division 1 and/or 2 locations. While the NEC does recognize the Zone system under Articles 505 and 506, a majority of the existing area classifications throughout North America are classified under the Class and Division system. The NEC does allow, on a limited basis, the use of Zone certified equipment to be installed in Class and Division classified areas. In Europe and in many other countries, commonly used concepts in addition to the ones suitable for North America such as Increased Safety Ex ‘e’ (primarily used for AC Motors, junction boxes and luminaries) and Encapsulation are widely used, along with the lesser used concepts such as Oil Filled or Powder Filled. In addition, ATEX Certification requires that ‘all’ potential ignition sources are addressed, including non-electrical sources such as friction, impact, static and RF. Many additional protection concepts such as ‘c’; constructional safety or ‘b’; control of ignition sources, adding additional complexity to skid or assembly approvals. The division system uses ”explosion proof[2]” flame path cooling in Division 1 and Division 2 locations; but, in the Zone system does not allow this "flameproof" methodology in Zone 0. For all practical purposes, the T-ratings for both systems are identical. The zone system allows intrinsic safety with two fault conditions applied (ia), as the division system permits, and a lesser form of intrinsic safety that is only safe with one fault applied (ib). www.intertek-hazloc.com
  • 8. Hazardous locations: EU & NA requirements In both the division and zone system, purging and pressurizing is permitted in all locations. The use of "increased safety" (Ex e) protection isn't recognized by the Division system; but the Zone system permits its use in all but Zone 0 locations. Encapsulation (Ex ma and Ex mb) isn't a recognized protection method in the Division system; but the Zone system uses it frequently. "Special Protection" (Ex s) is not recognized within the division system; but, the Zone system allows a mechanism whereby apparatus and equipment can be certified to be safe and workable in a given location, though it does not comply with the other recognized forms of protection. Equipment certified for use in a Zone 0 can also be installed in a Zone 1 or 2; likewise equipment certified for use in Class I Div 1 can also be installed in Class I Division 2 locations. North America In North America-Division, Class, and Group Categories: Division I - There is a high probability of an explosive atmosphere in normal operation. This can be for part of the time, up to all the time. Division 2 - There is a low probability of an explosive atmosphere being present during normal operation. The North American class designations are: Class I - Contains flammable gases or vapours in quantities large enough to produce an explosion. Class II - Is hazardous due to the presence of combustible dust in the air. Class III - Contains easily ignitable fibres or flyings in the air. However, the quantities of fibres and flyings suspended in the air are not likely to be large enough to cause an explosion. Group designations further define the types of gases, and dusts Example of an American certification would be: Class 1, Div I, Groups A, B and C; Div 2, Groups F and G www.intertek-hazloc.com
  • 9. Hazardous locations: EU & NA requirements NEC System NEC Class I: Class II: Class III: Gases Dusts Combustible Fl i & Fib Div I Div 2 Div I Div 2 Group A: Group A Group E: Note: Group E Acetylene Metal Div 1 only Group B: Group B Group F: Group F Hydrogen Coal Group C: Group C Group G: Group G Ethylene Grain Group D: Group D Propane www.intertek-hazloc.com
  • 10. Hazardous locations: EU & NA requirements IEC Zone System IEC Group I Group II Gas Sub Group IIA Group IIB Group IIC Dust Zones For identifying dust areas in Europe, zones 20, 21 and 22 have been introduced, the definition of dust zones is similar to that for gas zone i.e. 0, 1 and 2. [1] Categories not to be confused with categories used in the ATEX Directive 94/9/EC [2] The North American terminology “Explosion proof” is known as flameproof in Europe and rest of the world Part 2: Ingress protection and Enclosure ratings Ingress protection (IP) is commonly required for most protection concepts in Europe, while in North America considers enclosure type ratings (NEMA or Type) as well as IP ratings. In addition, Hazardous Area equipment that may be located outdoors often requires a higher rating than the protection concept specifies. When certifying a product for both Europe and North America, it is important to understand the ‘highest’ specification that will be required and work to that design. The division system maintains a listing of types of enclosures, such as Type 4, or 7, 12, while in the Zone system this is known as the Ingress Protection (IP) system. The IP system designates, by means of a number, the degree of protection provided by an enclosure against solid objects. It also has a second www.intertek-hazloc.com
  • 11. Hazardous locations: EU & NA requirements number to designate the degree of protection provided by the enclosure against water ingress. For example, an IP number of 54 would eliminate the possible ingress of dust and protect against splashing water from any direction. What are IP ratings? IEC (International Electro technical Commission) Publication 60529 Classification of Degrees of Protection Provided by Enclosures provides a system for specifying the enclosures of electrical equipment on the basis of the degree of protection provided by the enclosure. IEC 60529 does not specify degrees of protection against mechanical damage of equipment, risk of explosions, or conditions such as moisture (produced for example by condensation), corrosive vapours, fungus, or vermin. The European standard is based on IEC529 which in Europe is EN 60529. This standard was originally used for electrical enclosures, however under ATEX 94/9/EC which is implemented in the UK as the Equipment and Protective System Regulations 1996, this now equally applies to non-electrical equipment. Refer to the chapter on equipment marking for further details. The Ingress Protection (IP) ratings are developed by the European Committee for Electro Technical Standardization (CENELEC) and specify the environmental protection an enclosure provides. The IP rating normally has two (or three) numbers: 1. Protection from solid objects or materials 2. Protection from liquids 3. Protection against mechanical impacts (commonly omitted) The rating refers to the equipment's ability to permit solids and liquids to penetrate the equipment enclosure. Electrical equipment’s IP rating is expressed as a two-digit number. The first number designates protection from solids, while the second number designates protection from liquids. It is important that manufacturers have their equipment certified by an outside laboratory to verify the product's IP rating. Epsilon is one such organisation which can verify the equipments IP rating; there are other companies that provide this service. The important thing is that the product is certified by an outside organization. If IP ratings are specified on a product's data sheet, then an approval certification number should also be included. An "x" is used for one of the digits if there is only one class of protection; i.e. IPX4 which addresses liquids only. www.intertek-hazloc.com
  • 12. Hazardous locations: EU & NA requirements First Digit The first digit of the IP code indicates the degree that persons are protected against contact with moving parts (other than smooth rotating shafts, etc.) and the degree that equipment is protected against solid foreign bodies (dusts) intruding into an equipment. 1st Digit - Protection against solids / dust IP Test Comment 0 No protection Protected against solid bodies 1 greater than 50mm diameter. (e.g. accidental contact with the hand) Protected against solid bodies 2 greater than 12.5mm diameter. (e.g. finger) Protected against solid bodies 3 greater than 2.5mm diameter (e.g. tools, wires) Protected against solid bodies 4 greater than 1.0mm diameter (e.g. thin tools and fine wire). Protected against dust (no harmful 5 deposit) Dust Proof Completely protected against dusts 6 Dust Tight www.intertek-hazloc.com
  • 13. Hazardous locations: EU & NA requirements The table below shows the particle size used in the first digit of the IP rating, the table is an accurate representation. Table 1: Size chart IP2X= IP3X= IP1X= 50mm IP4X= 1mm IP5= Dust 12.5mm 2.5mm . . www.intertek-hazloc.com
  • 14. Hazardous locations: EU & NA requirements Second Digit The second digit indicates the degree of protection of the equipment inside the enclosure against the harmful entry of water or moisture (e.g. dripping, spraying, submersion, etc.) 2nd Digit - Protection against water / moisture IP Test Comment 0 No protection Protected against vertically falling 1 drops of water (condensation) Protected against drops of water 2 falling up to 15° from the vertical Protected against water sprayed 3 up to 60° from the vertical Protected against splashing water 4 from all directions Protected against jets of water 5 from all directions Protected against powerful jets of 6 water from all directions Protected against the effects of 7 temporary immersion in water Protected against the continuous effects of immersion in water 8 having regard to specific conditions www.intertek-hazloc.com
  • 15. Hazardous locations: EU & NA requirements North American Enclosure Type Rating (NEMA) The American form of Enclosure rating is known as NEMA or Type. NEMA is an acronym for National Electrical Manufacturers Association. Standards covering environmental considerations for electrical enclosures are UL 50E, CSA C22.2 No. 94.2 and NEMA 250. NEMA Standard No. 250 provides the following information. NEMA Standards Publication 250 does test for environmental conditions such as corrosion, rust, icing, oil, and coolants. For this reason, and because the tests and evaluations for other characteristics are not identical, the IEC Enclosure Classification Designations cannot be exactly equated with NEMA Enclosure Type Numbers. The definitions for each type of enclosure are given below: Type 1: Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt). Type 2: Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). Type 3: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. Type 3R: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. Type 3S: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to www.intertek-hazloc.com
  • 16. Hazardous locations: EU & NA requirements provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and for which the external mechanism(s) remain operable when ice laden. Type 3X: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure. Type 3RX: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that will be undamaged by the external formation of ice on the enclosure that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. Type 3SX: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion; and for which the external mechanism(s) remain operable when ice laden. Type 4: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure. Type 4X: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of www.intertek-hazloc.com
  • 17. Hazardous locations: EU & NA requirements protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. Type 5: Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and settling airborne dust, lint, fibres, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). Type 6: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during occasional temporary submersion at a limited depth); and that will be undamaged by the external formation of ice on the enclosure. Type 6P: Enclosures are constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during prolonged submersion at a limited depth); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure. Type 12: Enclosures are constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibres, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). Type 12K: Enclosures are constructed (with knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibres, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). www.intertek-hazloc.com
  • 18. Hazardous locations: EU & NA requirements Type 13: Enclosures are constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibres, and flyings); to provide a degree of protection against harmful effects on the equipment due to the ingress of water (dripping and light splashing); and to provide protection against spraying, splashing, and seepage of oil and non-corrosive coolants. The following table provides a guide for converting from NEMA enclosure type numbers to IP rating. The NEMA Types meet or exceed the test requirements for the associated IEC Classifications; for this reason, the table should not be used to convert from IP rating to NEMA. IP NEMA Application Comment Equivalent Protected against accidental contact, 1 Indoors IP20 limited amount of dirt 2 Indoors Intrusion of dripping water and dirt Protection against dust, rain. No 3 Outdoors IP64 damage when ice forms on housing Protection against rain. No damage 3R Outdoors IP22 when ice forms on the housing Protection against dust, rain and hail. 3S Outdoors No damage when ice forms on the IP64 housing Protection against splash water, dust, 4 Indoors/Outdoors rain. No damage when ice forms on IP66 the housing Protection against splash water, dust, rain. No damage when ice forms on 4X Indoors/Outdoors IP66 the housing. Protected against corrosion Protection against dust, water jet and water during temporary submersion. 6 Indoors/Outdoors IP67 No damage when ice forms on the housing Protection against water during longer 6P Indoors/Outdoors submersion. Protected against corrosion Protection against dripping water. 11 Indoors Protected against corrosion 12, Protected against dust and dripping Indoors IP55 12K water Protected against dust and splash 13 Indoors IP65 water, oil and non-corrosive liquids www.intertek-hazloc.com
  • 19. Hazardous locations: EU & NA requirements For more information on Intertek’s services for hazardous location product testing, site assessment and technical training capabilities or to begin your project right away, Call: 1-800-WORLDLAB Email: icenter@intertek.com, info.uk@intertek.com or visit: www.intertek-hazloc.com Our Hazardous Location Credentials Intertek has one of the largest and most experienced hazardous location teams available at multiple locations world-wide. Our expertise is backed by a number of accreditations and recognitions including: • OSHA recognized Nationally Recognized Testing Laboratory (NRTL) for Hazardous Location Divisional Listing • Standards Council of Canada accredited Certification Body (CB) and Testing Organization (TO) • Notified Body and UKAS Accredited for the ATEX Directive, 94/9/EC. • IECEx Certification Body (CB) and Test Laboratory (TL) • Full Hazloc Training including an Accredited COMPEX Training Center • Site Services (Risk Assessment, Area Classification and Inspection) We certify products for compliance to National and International published standards which satisfy the applicable requirements of the National Electrical Code (NEC) in the U.S., the Canadian Electrical Code (CEC) in Canada, IECEX and the European Union's ATEX Directive. Some of the standards we test to include those of ANSI, UL, IEC, CSA, MIL Specs, FM, and CENELEC and CEN. This publication is copyright Š Intertek and may not be reproduced or transmitted in any form in whole or in part without the prior written permission of Intertek. While due care has been taken during the preparation of this document, Intertek cannot be held responsible for the accuracy of the information herein or for any consequence arising from it. Clients are encouraged to seek Intertek’s current advice on their specific needs before acting upon any of the content. www.intertek-hazloc.com