Ion Chromatography is designed with a bipolar conductivity detector to improve instrument detection performance and stability. Boasts a modular design coupled with advanced
circuit technology. It provides a flow range spanning from 0.001 to 9.999 ml/min and has a detection range spanning from 0 to 35,000 µS/cm. It is exclusively crafted for the
separation, identification, and quantification of ions within a sample.
1. Ion Chromatography
www.labmate.com | info@labmate.com
Overview
Ion Chromatography is designed with a bipolar conductivity detector to improve
instrument detection performance and stability. Boasts a modular design coupled
with advanced circuit technology. It provides a flow range spanning from 0.001 to
9.999 ml/min and has a detection range spanning from 0 to 35,000 µS/cm. It is
exclusively crafted for the separation, identification, and quantification of ions
within a sample.
2. Specifications :
Ion
Chromatographic
Pump
Type High pressure and low pulse
double plunger tandem
advection pump
Maximum
pressure
35 MPa (PEEK)
Pressure
display
accuracy
(0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow stability 0.001 to 9.999 ml/ min
Flow range 0.001 to 9.999 ml/ min
Pressure
pulse
≤ 0.5%
3. Conductivity
detector Type Temperature Control and
Bipolar Conductivity Detector
Detection
mode
Bipolar conductivity detection
Cell volume ≤ 0.8 µL
Detection
range
0 to 35000 µS/ cm
Detection
resolution
≤ 0.0020 nS/ cm
Output
voltage
-6000 to +6000 mV
(adjustable)
Baseline
noise
≤ 0.05 % F.S.
Baseline
drift
≤ 3 % FS/ 30 min
Operating
temperature
range
Room temperature +5 to 60°C
(41 to 140°F)
5. Flow system
Plastic flow
path
Made of PEEK materials
Six-way
Valve
PEEK material, 5000 psi
pressure, independent
automatic collection, and flow
function
Degassing
Device Inner
volume
300 µl
Degassing
volume
7.5 ml
Maximum
flow rate
10 ml/ min
Degassing
efficiency
Degassing 90 % at 1ml/ min
Organic
tolerance
1
6. Built-in Eluent
Generator Eluent
types
KOH/ NaOH
Eluent
concentrat
ion range
0.1 to 100 mM
Concentra
tion
increment
0.1 mM
Flow rate
change
0.1 to 3.0 ml/ min
Maximum
pressure
20 MPa
Minimum
pressure
5 MPa
Power supply 150 W
Dimension 350 × 470 × 650 mm
7. Net weight 34 kg
Gross weight 40 kg
Features :
- Featuring a gradient elution system, efficiently detects small molecules
in complex samples
- Incorporate temperature control for optimal analysis conditions
- Includes automated components and software to streamline analysis
- Built-in low-pressure degassing technology to remove bubble
interference
- Automated self-regenerating electrolytic microfilm suppressor
- Enhanced with standard dilution function that saves time, labor, and
costs
- RS232 and USB interfaces
Standard Accessories :
Ion Chromatography host:1
High-pressure advection pump:1
Conductivity detector:1
Anion column:1
Anion guard column:1
Suppressor:1
Chromatography workstation:1
Column thermostat system:1
8. Spare parts kits :1
Vacuum degassing pump:1
Sand core filtration devices:1
Pretreatment column:20
0.22 µm syringe filter:200
Eluent generator:1
Optional Accessories :
Autosampler (20 samples)
Autosampler (54 samples)
Autosampler (108 samples)
Anion column
Guard column
Anion suppressor
Spare parts kits
Applications :
Ion Chromatography finds application in various scientific and industrial fields
such as Environmental Monitoring, Pharmaceutical Analysis, Research
Laboratories, and more.
Labmate Scientific Email: info@labmate.com | Website: www.labmate.com