2. GPRS/SMS ACTM User Manual
٢
Notice:
Copyright
The contents of the manual are protected by Chinese law, any
organization and/or person cannot copy this manual or part of contents
without Arian Ertebat Caspian Co. authorization in written.
Trademark
ACTM, GPRS ACTM are the logos and trademarks of Arian Ertebat Caspian Co.
The other company trademarks and logos in this manual are owned by the
owner, Arian does not have the right for those trademarks and logos.
3. GPRS/SMS FAM User manual
٣
Contents
CHAPTER ١ INTRODUCTION ........................................................................................................... ٥
١.١ Objective ..................................................................................................................................................................... ٥
١.٢ Application ................................................................................................................................................................. ٥
١.٣ Version......................................................................................................................................................................... ٥
١.٤ Convention ................................................................................................................................................................. ٦
١.٥ Technical Support ................................................................................................................................................... ٦
١.٦ Abbreviations ........................................................................................................................................................... ٧
CHAPTER ٢ PRODUCT INTRODUCTION .................................................................................. ١٠
٢.١ Introduction ............................................................................................................................................................ ١٠
٢.١.١ Size ............................................................................................................................................................................. ١١
٢.١.٢ Accessories ............................................................................................................................................................ ١٢
٢.٢ System function and feature ............................................................................................................................ ١٢
٢.٢.١ Main function ........................................................................................................................................................ ١٢
٢.٢.٢ Part of compatible sensor ............................................................................................................................... ١٤
٢.٣ Specification ............................................................................................................................................................ ١٥
CHAPTER ٣ INSTALLATION.......................................................................................................... ١٨
٣.١ ACTM installation and cable connection .................................................................................................... ١٨
٣.١.١ Antenna and SIM card installation .............................................................................................................. ١٨
٣.١.٢ RS٢٣٢ configuration and Power cables installation ............................................................................ ١٨
٣.٢ Sensors installation .............................................................................................................................................. ١٩
٣.٢.١ DI (Digital Input) sensor installation ......................................................................................................... ٢٠
٣.٢.٢ AI (Analog Input) Sensor installation ........................................................................................................ ٢١
٣.٢.٣ DO (Digital Output) device installation ..................................................................................................... ٢١
٣.٢.٤ TE (Temperature) sensor installation ....................................................................................................... ٢٢
٣.٢.٥ Wireless Sensor installation ........................................................................................................................... ٢٢
٣.٢.٦ Camera installation ............................................................................................................................................ ٢٢
٣.٢.٧ RTU device installation .................................................................................................................................... ٢٣
٣.٣ Grounding ................................................................................................................................................................ ٢٤
٣.٤ Power supply .......................................................................................................................................................... ٢٤
٣.٥ Check the mobile network ................................................................................................................................ ٢٤
CHAPTER ٤ TERMINAL CONFIGURATION ............................................................................. ٢٦
٤.١ Device Connection ................................................................................................................................................ ٢٦
٤.٢ Parameter Configuration ................................................................................................................................... ٢٨
5. GPRS/SMS FAM User manual
٥
Chapter ١ Introduction
This chapter describes the manual functions and role, also tells the reader how to
read the manual, it's best guidance document for install and use Arian
GRPS/SMS ACTM.
١. Objective
٢. Application
٣. Version
٤. Convention
٥. Technical Support
٦. Abbreviations
١.١ Objective
This manual mainly ACTM-٩٢٢٠ Quick Start Guide for reference that written to
guide ACTM-٩٢٢٠ ACTM installation products.
١.٢ Application
This manual applies to a certain computer communications networks, industrial
automation control and electronic technical knowledge, network equipment,
administrators, engineers and other industrial control which need to use
ACTM-٩٢٢٠ ACTM that relevant managers.
Applies to version: ACTM-٩٢٢٠ ACTM V١.٠ and below versions.
١.٣ Version
According to the market requirement, Arian ACTM-٩٢٢٠ ACTM product-related
functions will be adjusted as well as technical improvements. Since the authors
have a variety of reasons may cause the contents of revised instructions, the
below table show Arian ACTM-٩٢٢٠ product specifications revised at different
times and revised version of the reasons for that.
Version Modify
department
Participating
departments
Date detail
6. GPRS/SMS FAM User manual
٦
١.٤ Convention
For ease of use, fast reading manual, we have some short name, icons,
description, security alerts, tips and other conventions are as follows:
Convention Description Memo
ACTM-922
0
Arian ACTM-9220 GPRS/SMS
ACTM
Support ٣ DI, ١ AI, ١ DO
ports
ACTM-922
0
ET8600 series GPRS/SMS
ACTM products
Support ٧ D, 1 AI, ٤ DO
ports, Support Wireless
Sensor
ACTM GRPS/SMS ACTM
Suggestion Installation time-saving tips or
experience
Appear in this manual
installation and testing
Notice Prompt the user or reader to
pay attention the important
information or parameters
Appear in this manual
operation
Warning A serious warning, such as the
improper use of the
temperatures, voltage,
unstable environment
Appear in this manual
production introduction
and installation
Attention General warning: prompt the
user some illegal operation or
improper use of operations
١.٥ Technical Support
To allow users to quickly solve difficult problems, get the correct solution for
hardware, operating system and installation. The following ways to contact Arian
7. GPRS/SMS FAM User manual
٧
١.٦ Abbreviations
The Manual related abbreviation meaning:
APN Access Point Name
APP Application
ATM Asynchronous Transfer Mode
ATM Auto Table Machine
AuC Authentication Centre
BG Border Gateway
BGP Border Gateway Protocol
BSC Base Station Controller
BSCC Base Station Control Connection
BSS Base Station System
BSSGP BSS GPRS Protocol
BTS Base Transceiver System
CDMA Code Division Multiple Access
CDR Call Detail Record
CGF Charging Gateway Function
CSD Circuit Switch Data
DDN Digital Data Network
DHCP Dynamic Host Configuration Protocol
DNS Domain Name System
DSC Data Service Center
DTU Data Terminal Unit
EGP External/Exterior Gateway Protocol
EIGRP External/Exterior Internet Group Routing Protocol
EMC Electro Magnetic Compatibility
ESP Electro Static Precautions
ETSI European Telecommunications Standards Institute
GGSN Gateway GPRS Support Node
GMSC Gateway MSC
GPRS General Packet Radio Service
GSM Global System for Mobile Communications
GSN GPRS Support Node
GTP GPRS Tunneling Protocol
GTP-id GTP Identity
ACTM Fixed Asset Monitor
HLR Home Location Register
HSCSD High Speed Circuit Switch Data
8. GPRS/SMS FAM User manual
٨
IGMP Internet Group Management Protocol
IGRP Internet Gateway Routing Protocol
IN Intelligent Network
IP Internet Protocol
IPv٤ IP version ٤
IPv٦ IP version ٦
IPSEC IP Secure Protocol
ISDN Integrated Services Digital Network
ISP Internet Service Provider
L٢TP Layer ٢ Tunneling Protocol
LA Location Area
LLC Logical Link Control
MAP Mobile Application Part
MDNS Mobile Domain Name System
MS Mobile Station
MSC Mobile Switching Center
MT Mobile Terminal
MTBF Mean Time between Failures
MTTR Mean Time to Recovery
N/A Not Applicable
NAS Network Access Server
NAT Network Address Translation
NTP Network Time Protocol
O&M Operations & Maintenance
PAP Password Authentication Protocol
PCF Packet Control Function
PDP Packet Data Protocol
PDN Packet Data Network
PDSN Packet Data Service Node
PLMN Public Land Mobile Network
POS Point of Sales
PTM-G Point-to-Multipoint Group Call
PTM-M Point-to-Multipoint Multicast
QoS Quality of Service
RA Routing Area
RADIUS Remote Authentication Dial In User Service
RIP Routing Information Protocol
RSC Register Service Center
RTOS Real Time Operating System
RTP Real-time Transport Protocol
9. GPRS/SMS FAM User manual
٩
RTU Remote Terminal Unit
SCADA Supervisory Control and Data Acquisition
SGSN Serving GPRS Support Node
SIM Subscriber Identify Module
SMS Short Message Service
SMSC Short Message Service Center
SNMP Simple Network Management Protocol
STK SIM Tool Kits
TCP Transmission Control Protocol
TDMA Time Division Multiple Access
TMN Telecommunication Managed Network
TTL Time to Live
UDP User Datagram Protocol
UIM User Identify Module
UMTS Universal Mobile Telecommunication System
USSD Unstructured Supplementary Service Data
UTK UIM Tool Kits
VLR Visitor Location Register
WAN Wide Area Network
WAP Wireless Application Protocol
WDDN Wireless Digital Data Network
10. GPRS/SMS ACTM User manual
١٠
Chapter 2 Product Introduction
This chapter describes the overview of the ACTM system, function and
specification, by reading this chapter, the reader can understand the ACTM
system configuration, product accessories and detail function.
١. Introduction
٢. System function and feature
٣. Specification
٢.١ Introduction
GPRS network theoretically can provide a maximum bandwidth ١٧١.٢Kbps, actually, it
works at ٤٠~١٠٠Kbps bandwidth (it depends on service provider’s operation policy). As we
know, GPRS is packet based network which provides TCP/IP communication channel.
GPRS/SMS ACTM (Fixed Asset Monitoring) is an enhanced GPRS/SMS messenger (GPRS or
CDMA service optional) which integrated with I/O port, RTU (Remote Terminal Unit),
Relay, Sensor functions, it can help people to monitoring, control,SMS alarm the remote
devices.
GPRS/SMS ACTM main apllication filed is Home Security, Power grid automatization,
industrial monitoring, traffic management, weather, finance, Basic Environmen protecting,
colliery, Oil field etc, especially, apply in security, remote control. Implement transparent
data transmission over GPRS/SMS network.
The Typical system diagram is as below:
11. GPRS/SMS ACTM User manual
٢.١.١ Size
ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram,
according the different applications, there are mounting holes on both sides to meet the
needs of a variety of industrial applications.
ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram,
according the different applications, there are mounting holes on both sides to meet the
needs of a variety of industrial applications.
١١
12. GPRS/SMS ACTM User manual
١٢
٢.١.٢ Accessories
In order to protect products during shipment, ACTM-9220 GPRS/SMS ACTM has been
packed properly. You may need to keep the packing materials for reshipping after you
open the pack box.
ACTM-9220 ACTM package includes:
ACTM-9220 ACTM ١ piece (Packed according to P/O)
+12V Power adapter ١ piece
2.5 meters antenna ١ piece
User manual ١ Piece(CD-ROM)
Qualified & Repair Card ١ piece
Optional Accessories:
9Dbi High gain magnet antenna
Yagi antenna
Fixed antenna
Cascading Cable(SMA interface)
Configuration and firmware update cable
After you open the box, you should count it carefully with your purchase order.
٢.٢ System function and feature
٢.٢.١ Main function
Industrial Design
GPRS/SMS ACTM is industrial design which built-in watchdog chipset to ensure the system
work continuously, Watchdog monitoring the GPRS module and CPU all the time, if the
GPRS module or CPU does not response for long time, ACTM will restart automatically.
ACTM is very suitable for long-term continuous work applications.
Support Wireless Sensor
ACTM-٩٢٢٠ GPRS / SMS ACTM supports RF wireless sensors, connected through
RF٤٣٣.٩٢Mhz frequency with wireless sensors, ٨-way wireless zones, support ٤٠ wireless
sensors, and real-time monitoring of the state of the sensor, when the sensor battery is
low or disconnect the connection, tamper switch, ACTM will send alarm information.
Transparent data transmission
GPRS/SMS ACTM provides full transparent data transmission channel through RS٢٣٢
interface it use for connect different types of PLC, RTU which extend the scope of ACTM
application, and better services for users.
Main and backup data center
13. GPRS/SMS ACTM User manual
GPRS/SMS ACTM support main and backup data center, user can set both main data
center ip address or domain name, when ACTM fail to connect with main data center, it will
try to connect backup data center automatically.
Embedded Li-battery and Temperature sensor
GPRS/SMS ACTM built-in ١٠٠٠mA Lithium battery, it can work for ٦ hours if the external
power supply cut off. Also, ACTM will send alarm message to notify the user that the
external power supply was cut off. the built-in temperature sensor can real-time
monitoring of environment temperature, ACTM also support t external digital temperature
sensor that monitor user’s device surface temperature, when the temperature lower or
higher than the specified value, ACTM will send alarm message, when the temperature
returned to normal, ACTM will send notice message to user also.
User-define alarm SMS
GPRS/SMS ACTM support User-define alarm SMS, according to alarm port status, ACTM
will choose the user pre-define content, and send to user mobile phone by SMS, it’s easy
for user to understand alarm message.
I/O status Buffer
ACTM has NVRAM buffer to save the I/O status data during GPRS/SMS tunnel problem,
when the GPRS/SMS tunnel return to normal, ACTM will send buffer all data immediately,
NVRAM has feature for save data even power lose, so even ACTM power lose, the buffer
data will still save.
Ring and SMS alarm
ACTM support ring and SMS for sending alarm message, when the alarm occurred, ACTM
will start ring for ١٠ seconds, and then send alarm SMS to users. Users also can remote
setting and control ACTM by SMS.
SMS receipt
To ensure user receive the alarm messages, user can set the alarm SMS resend frequency,
unless the alarm clear or receive ACK message receipt from user phone, ACTM will repeat
to send alarm SMS by Specified frequency and interval.
Alarm clear message
All of ACTM I/O port can be set the alarm clear message, when the port alarm status clear,
ACTM will send alarm clear SMS to notice user.
Regularly report the I/O status
ACTM-٩٢٢٠ ACTM support auto send I/O port status by specified time, after user set the
time, ACTM will send the port status on specified time daily.
١٣
DO port programmable output
ACTM DO (digital output) port supports programmable output, according to the
requirement of user site, the level of output level, switching time, times would be
programmable.
Zone type
ACTM DI ports support zone type setting which can be set to as common zone, delay zone,
intelligent zone, emergency zone, home zone, according to the user site conditions and
sensor type, set the correct zone type to prevent false alarm, missing alarm.
GPRS SMS work at the same time
14. GPRS/SMS ACTM User manual
ACTM communication through GPRS to data center, at the same time, ACTM also can occur
SMS to the user's mobile phone, so that’s insuring the user receive the alarm message via
GPRS and SMS.
Timing arm/disarm, password arm/disarm
ACTM support timing arm/disarm function, it can perform a specified time every day to
arm/disarm; ACTM also support any mobile phone number via a password to arm/disarm,
after the instruction is executed successfully, ACTM will arm/disarm information to the
administrator phone as well.
Camera capture picture
ACTM provides the interface to connect with camera, real-time remote image capture, with
the ACTM IO ports, real-time capture images when an alarm is generated, and sent to the
data center; ACTM can be set to a fixed time interval for continuous capture images as
well.
MODBUS Protocol programmable output
ACTM provides storage and forwarding the command functions of the MODBUS protocol,
users can pre-save the common command to ACTM, and ACTM will send the command
PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically.
١٤
Clock synchronization
ACTM support clock synchronization; it can read the clock from SMS or get clock from
management platform by GPRS.
Cell phone and PC be Data service center
GPRS/SMS ACTM supports cell phone and PC server to be data service center, if PC to be
service center, please use Arian ACTM management platform software, it supports SQL
data base, Google map etc. it can monitor thousands ACTM via GPRS; if the stations
exceeds ٥٠٠ points, we suggest use ACTM management platform.
Graphical configuration software
ACTM-٩٢٢٠ GPRS/SMS ACTM provide full graphical software configuration, easy to use,
and supports import or export configuration file; so users just simply click a few icons to
quickly setup ACTM system.
Worldwide applications
GPRS/SMS ACTM has broad range of applications; it can be used in industrial remote
monitor, security, meteorology, environmental protection, water conservancy, electric
power industries.
To more suitable of industrial M٢M applications, Arian can quickly modify the software and
hardware according to customer requirements.
٢.٢.٢ Part of compatible sensor
The below item is part of ACTM compatible sensors:
Float Water Level Sensor
Temperature Sensor
Pressure Sensor
Magnetism Detector
Speed Sensor
Flow Sensor
Infrared Detector
Shock Sensor
Wind Sensor
Smoke Sensor
Lighting Sensor
Gas/LPG Detector
15. GPRS/SMS ACTM User manual
١٥
Humidity Sensor
Dynamo Sensor
Water immersion Sensor
Relay
Microwave Motion Sensor
Voltage Sensor
Horizontal Sensor
Emergency Button
Sound & Flash Siren
٢.٣ Specification
Basic
GPRS Dual Bands ٩٠٠Mhz/ ١٨٠٠Mhz
GPRS Quad Bands ٨٥٠/٩٠٠/١٨٠٠/١٩٠٠Mhz (Optional)
CDMA ٨٠٠mhz (Optional)
Dual SIM Slot (Optional)
Self-define re-connecting interval
Clock synchronizing
Support external temperature sensor
Embedded Temperature Sensor
Support Temperature verify
I/O status buffer
Self-define report I/O status daily
Self-define online report interval
AI and the TE port upper and lower limits
DO port programmable output
DI port zone type setting
Timing, password arm/disarm
GPRS SMS work at the same time
MODBUS Protocol programmable output
Optical isolation terminal
Smart power management
Automatic power supply detection
Li-Battery inside (Optional)
Support ٢ DI pulse input (Optional)
Support GPS (Optional)
Support Max ١٦ Temperature sensors (Optional)
Support camera to Photograph
Support alarm link to photograph
PC based configuration tool
Real time OS, steady system
Watch dog design, ensure ACTM alive
Low consumption, industrial design
Fully type approved with ETSI GSM Phase ٢+ standard
Enhanced EMC/EMI design
GPRS
Industrial class GPRS wireless module
Embedded PPP, TCP/IP Stack
Support main and backup service center
Support TCP/IP and UDP/IP
Transparent data transmission
Support RS٢٣٢ interface for data transmission
16. GPRS/SMS ACTM User manual
١٦
Supports DNS and dynamic data service center IP address
Support continually or sleep work mode
Support Carrier public & special APN
Work with ACTM management platform
Remote monitoring and control
SMS
Support SMS and Ring Alarm
Set defense by SMS
Self-define SMS alarm message
Alarm/Disarm by SMS
Automatic send alarm SMS to mobile phone when alarm is triggered
Support ٤ service center number, and customized setting for center
SMS query ACTM signal strength
DO Relay triggered by alarm or SMS
Automatic SMS alarm when data above or below the preset levels
Support SMS remote configuration
Alarm clear message
Alarm SMS receipt and acknowledgement
RF Wireless
Frequency: ٤٣٣.٩٢Mhz
Wireless transmission distance: ١٠٠meter standard environment
Support sensor low battery alarm
Support sensor Tamper alarm
Support sensor disconnect alarm
Real-time monitoring of sensor status
Anti-RF interference
٨ wireless zones
Supports ٤٠ wireless sensor
Support ٥ remoter
Support wireless zone type setting
Interface
Antenna: ٥٠Ω/SMA Female
SIM/R-UIM: ٣V
Configuration: RS٢٣٢
Data: RS٢٣٢ (RS٤٨٥, Ethernet Optional)
DI: ٣ Ports (٠-٣V False, ٣-٣٦V True)
AI: ١ Port
DO: ١ Port
TE: ٢ ports
Note: DI = Digital Input
AI = Analog Input
DO = Digital Output
TE = Temperature
Power
Voltage: ١٢V~١٨VDC (١٢~٣٠V Optional)
18. GPRS/SMS ACTM User manual
١٨
Chapter 3 Installation
This chapter describes in detail about ACTM system hardware installation,
cable and sensor connections, by reading this chapter, the reader should be able to
complete the ACTM hardware installation.
١. ACTM installation and cable connection
٢. Sensors installation
٣. Grounding
٤. Power supply
٥. Check the mobile network
٣.١ ACTM installation and cable connection
GPRS/SMS ACTM should be installed and configured properly before putting it in service.
The installation and configuration should be done or supervised by Arian qualified
engineer.
Attention:
Do not install GPRS/SMS ACTM or connect/disconnect its cable when it is power on.
3.1.١ Antenna and SIM card installation
Using the antenna or other sharp items to click the top of the yellow dots SIM card
connector, SIM card slot will automatically pop up, please put SIM card into the slot, and
push the SIM card connector to the slot. The picture shown is as below:
3.١.٢ RS232 configuration and Power cables installation
ACTM-9220 ACTM signals and power supply is connected by industrial class pluggable
terminals, ٣.81mm, ١٢Pin, and ١٤~٢٤AWG outlet cable is recommended. Each line
definition refers to the following diagrams and tables. Also, you can find outlet cable
definition table at top of ACTM-9220 ACTM cover.
As shown in the following diagrams and tables, peel off the cable end about ٧mm and
connect each terminal and cable (١٤~٢٤AWG cable recommended. Make sure that you
have connected the terminals without any mistake.
19. GPRS/SMS ACTM User manual
١٩
٧mm
14~24AWG
٧٧mm
PIN Signal name Description MEMO
Vin +5~18V Power Vin, recommend
12V
80mA@12V
GND GND Power GND
Vout Power Output This PIN voltage
is same Vin
DI1 Digital Input 1 Voltage range: 0-36V
DI2 Digital Input 2 Voltage range: 0-36V
DI3 Digital Input 3 Voltage range: 0-36V
GND GND Signal GND; common with
user’s device; RS232 GND
AI1 Analog Input 1 Voltage range: 0-10V
DO1 Digital output 1 Default is low level This PIN voltage
is same Vin
TX Send data RS232 TX
RX Receive data RS232 RX
UG Software Upgrade After connect with GND,
ACTM will enter to
software upgrade status
Attention:
The power cable should be connected correctly. We suggest double check before switch it
on. Wrong connections may destroy the equipment.
Power terminals: Pin ١ and Pin ٢;
Here: Pin ١ is Power input “Vin” (+٥~+١٨VDC), Pin ٢ is”GND”.
٣.٢ Sensors installation
ACTM-9220 ACTM Provides 3 DI ports ,1 AI port,1 DO port. The sensors installation is as
below:
20. GPRS/SMS ACTM User manual
3.2.1 DI (Digital Input) sensor installation
DI sensor only two states, high level (٣-٣٦V) and low level (٠-٣V). There are ٢ kinds of DI
sensors, switching and voltage type.
Switch DI Sensor
The switching DI sensor is like a simple switch, it only has ٢ statuses, ON or OFF. Connect
the switch sensor ٢ signal lines to ACTM Vout pin and DI pins. it can be connected to
multiple sensors; the common switching DI sensor such as Magnetic sensor, float level
sensors, infrared sensors, pressure sensors, gas sensors, emergency buttons etc. the
connections diagram as shown below:
To achieve the alarm linkage, alarm equipment and DI port can be parallel interfaces to
achieve the alarm linkage. When Magnetic sensors have closed, the sound and light alarm
simultaneously closed, as follows picture:
Voltage DI Sensor
The Voltage DI sensor provide DC voltage, connect the sensor Pin+ to ACTM DI pin, GND
to ACTM GND, the common voltage DI sensor such as water immersion sensor, the
connection diagram as shown below:
٢٠
21. GPRS/SMS ACTM User manual
3.2.2 AI (Analog Input) Sensor installation
Voltage AI Sensor
Voltage sensor provide a voltage to the ACTM AI ports that required voltage between
٠-١٠V, connect sensor Vout to the ACTM AI pin, GND connect to ACTM GND, the
commonly used voltage AI sensor such as current sensor , Voltage sensor, fuel sensor etc.
shown as follows:
resistance AI sensor
Resistance AI sensor is like a variable resistor, such as resistance Humidity sensors, ١٠kΩ is
the standard resistance; its resistance to humidity changes as the actual changing.
Connect the sensor 2Pin to the ACTM AI and Vout pin. The commonly resistance AI sensor
such as humidity sensor and so on.
3.2.3 DO (Digital Output) device installation
ACTM DO port provides the same voltage a Vin pin, and not more than ٢٠٠mA of current
output. DO port can be used to control remote devices such as relays, photoelectric alarm,
and alarm speakers. The installation diagram showed as below:
٢١
22. GPRS/SMS ACTM User manual
Attention:
When the external power supply disconnect, ACTM will using internal battery power, the
internal lithium battery supply voltage as ٣.٧V, so the DO port cannot provide ١٢V voltage,
only output 3.7V voltage, so DO port will unfunctional.
DO port provides maximum ٢٠٠mA output current, if use DO port to control equipment
which more than ٢٠٠mA current, it should be added relay between ACTM and equipment.
3.2.4 TE (Temperature) sensor installation
ACTM provides two TE ports, TE٢ is the built-in NTC thermistor, the user can directly use it
without installation; TE٢ is an external digital temperature interface, the digital
temperature sensor connect to TE٢ port, it can be use for monitor equipment surface
temperature, ambient temperature, water temperature, oil temperature and so on. The
installation diagram showed as below:
3.2.5 Wireless Sensor installation
ACTM supports wireless sensors, wireless sensor using ٤٣٣MHZ RF to connect with ACTM
controller, just assembled wireless sensor battery, and then through ACTM configuration
tool to registered wireless sensor, the sensor would be connect to ACTM successfully.
3.2.6 Camera installation
ACTM supports camera capture picture function, camera connect to ACTM via RS232 port,
DC 12V Power, the installation diagram showed as below:
٢٢
23. GPRS/SMS ACTM User manual
Please connect camera cable to ACTM according to the above figure cable color:
Camera ACTM
Green ----> RX
Yellow ----> TX
Black ----> GND
Red ---- > Vout
After finish the ACTM and camera cable connection, we need to complete the
implementation of the following actions:
Turn OFF the debug information display on the configuration software
Turn ON the camera function on the configuration software
Disconnect the ACTM configuration cable to PC (ACTM mini-USB side)
Restart ACTM
Notice:
ACTM and the camera both is connected via the RS٢٣٢ interface, the camera can not be
used when the ACTM at configuration status. ACTM configuration cable must be
disconnecting, and then the camera should be work properly.
3.2.7 RTU device installation
ACTM provides RS٢٣٢ interface to connect other RTU device; it’s a three-line, installation
diagram shown as below:
٢٣
24. GPRS/SMS ACTM User manual
٣.٣ Grounding
To ensure a safe, stable and reliable ACTM-9220 GPRS/SMS ACTM operation, the ACTM
cabinet should be grounded properly. Connect the ACTM cabinet to site ground wire at the
ground point
٣.٤ Power supply
ACTM-9220 ACTM is designed with advanced power management technologies; it can
operate standalone. The DC power is supplied via pluggable terminal Pin ١ (Vin) and Pin ٢
(GND). Detail definitions refer to above tables.
Notice:
About Power Supply:
When ACTM-9220 GPRS/SMS ACTM communicates with base station, surge current will
exceed normal current. Therefore, margins ٥ times over normal current may be required
for external power supply.
Normally, ACTM-9220 ACTM input power supply is +٥~+18VDC, in most cases, ١٢VDC/١A
is recommended. Power supply ripple should be less ٣٠٠ mV.
٣.٥ Check the mobile network
Connect all signal and power cables, and double check it, connect antenna, insert a valid
SIM and switch on power. ACTM-9220 “PWR” LED will light up. After around 30 seconds, If
“NET” and “DATA” LED is flashing at same time (ON for 2 seconds then OFF for 2 seconds),
it means the ACTM-9220 ACTM is working normally. If the “DATA” LED is flashing, it means
there are data stream. If the “NET” LED lights up, it means that the ACTM-9220 ACTM has
found and logged on mobile network.
٢٤
25. GPRS/SMS ACTM User manual
Warning:
All cables should be connected correctly before switch on.
Antenna should be connected before switch on, otherwise it may cause radio module
problem
٢٥
26. GPRS/SMS ACTM User manual
٢٦
Chapter 4 Terminal Configuration
This chapter describes in detail about ACTM configuration software, by
reading this chapter, the reader should be able to know the function of ACTM,
and change the configuration according actual requirement.
١. Device Connection
٢. Parameter Configuration
٣. Parameter Detail
٤.١ Device Connection
ACTM graphical configuration software, it's easy to use and operation. Before the formal
operation on the device, ACTM-٩٢٢٠ ACTM must be set to correct parameters. ACTM
supports two ways to communication with PC.
Notice:
ACTM provide power switch (close the green socket), turn the power switch to the ON,
ACTM will power ON and start run.
By using Arian configuration cable connect to ACTM Console port, which has upgraded
firmware button (Blue Button) on the cable, when press in the button, ACTM will enter
to firmware upgrade mode, and all of 4 LED will be ON; when press out the button,
ACTM will enter to normal work mode, the Power LED will be ON, Data LED will be
flash. the connection diagram shown as Below:
27. GPRS/SMS ACTM User manual
Connect PC's RS٢٣٢ interface to the ACTM terminals RX, TX, GND pin, if Connect
ACTM terminal UG and GND pin together, ACTM will enter the software upgrade
status. the connection diagram shown as Below:
٢٧
28. GPRS/SMS ACTM User manual
٤.٢ Parameter Configuration
A. Connect ACTM
According the above two ways to connected PC and ACTM, and installed ACTM
configuration software on the PC.
Switch ON ACTM power, start ACTM configuration software on the PC, click the interface in
the navigation bar of the "OPEN “button, if the connection is successful, the software will
automatically connect with the ACTM, and ACTM read all configuration information. If the
connection is not successful, click on the navigation bar "PORT" button, select the correct
port number, baud rate is ١١٥٢٠٠, and then click "OPEN" to retry the connection.
When the information bar shows "Login Successful", it means that the configuration
software and ACTM-٩٢٢٠ ACTM connection is successful, the picture shown as follows:
٢٨
29. GPRS/SMS ACTM User manual
Attention:
After Configuration software connected ACTM successful, it will read ACTM configuration
information and refresh automatically, this process may takes about ٢٠ seconds, and will
slightly pause is normal.
Using the configuration software, please turn OFF the ACTM debugging information, the
debug information will affect the configuration software to read the ACTM information.
When the SIM card is not inserted, or ACTM in the TCP / UDP mode, if the GPRS
connection is not successful that ACTM will automatically restart, and then configure
software will appear that failure to read/set parameters, just simply click "Connect" button
on the navigation bar, ACTM will connect again.
B. Query Parameter
For query ACTM parameters, just click the optional checkbox in the left window (multiple
choice), then click the navigation bar "Query" button, the configuration software will query
the ACTM parameter information, and refresh the option box.
Notice:
if didn't tick any parameter options box, and click on "Query" button, ACTM will returns the
current status values of all the IO ports in the information bar, this feature is easy to test
sensor, and real-time query IO port status.
C. Set Parameter
To change the ACTM parameters, just click the optional checkbox in the left window
(multiple choices), then modify the parameter value detail, and click the navigation bar
"Save" button, the configuration software will save the parameter information to the
٢٩
30. GPRS/SMS ACTM User manual
ACTM, if save successful, it will show "the parameter have been save successful" in the
message window ", the picture shown as below:
Notice:
If didn't tick any parameter options box, and click on "Save" button, ACTM will implement
save command. After registrater the wireless sensor, you need by clicking on the "Save"
button to execute the save.
D. Series Port Configuration
Click the navigation bar "Port" button to open the serial port configuration window, it need
to select the appropriate connection port and the baud rate to connect to ACTM, the
picture shown as below:
Notice:
The default login password is ٠٠٠٠٠٠, please do not change this password if it's not
necessary; once change the parameter on the configuration page, you should also change
the same login password here, otherwise ACTM will not able to login.
٣٠
31. GPRS/SMS ACTM User manual
E. Series Port Window
The serial window is for testing and troubleshoots, click on the navigation bar "serial
window" button, the window from the parameter window into the serial port window, for
return parameter window, and just click "parameter window" button on the navigation bar.
Attention:
Send commands to the ACTM in the serial port window may bring unexpected problems;
usually, please do not enter to the serial port window mode.
F. Common Parameter
Click the navigation bar "Common setting" button to open the common parameter settings
window, you can select the frequency parameter to the common parameters window, and
it’s for mass and quickly configuration ACTM. the picture shown as Below:
G. All
Click the navigation bar "All" button, it will select all option on the Parameter Configuration
page, that’s easy for user to operation.
H. Clock Synchronization
Click the navigation bar "Clock Synchronization" button, ACTMcfg software will ready the
computer clock information, and write to ACTM.
Notice:
ACTM supports three way to clock synchronization: configuration software, SMS, Data
center via GPRS; by the configuration software and SMS clock synchronization, when
ACTM power lose, the clock will automatically be zero, and need to clock synchronization
again; by the GPRS mode, ACTM will clock synchronization by each login data center, we
recommend using GPRS for clock synchronization.
٣١
32. GPRS/SMS ACTM User manual
I. Restart
Click the navigation bar "restart "button, ACTM will immediately restart, and show "restart
the device successful "in the information bar, about ١٠ seconds, click the "Connect"
button , software will try to connect ACTM again.
J. Default Parameter
Click the navigation bar "Default “button, ACTM will revert all parameters to the default.
Attention:
This operation will restore ACTM parameters to factory state, it need to re-set ACTM
parameters in order for ACTM to work again.
K. Import/Export
Import / export feature is mainly used for quickly and easy to mass ACTMs, click the menu
bar "File “option under the "Export ", you can export the current configuration to be INI
file. Click menu bar "File “option under the "Import ", then select the INI file which saved
before, you can import the original configuration files in the current software
Suggestion:
"Import / Export" function can be used with the "Common Parameters” together, after the
import parameters, click "Common Setting" and "All" button, then click “Save" button, this
way will quickly save all of parameter you need.
Attention:
During "Import / Export “parameter, due to software will read/write large data, software
may pause a few seconds, its normal.
٤.٣ Parameter Detail
A. SIM Para.
Click the left mouse button on "SIM Para."; enter to the SIM card parameter setting, the
picture shown as below:
٣٢
33. GPRS/SMS ACTM User manual
APN Name (APN)
Follow the prompts to enter information into the access point name (access point name
cannot be empty), enter the characters that not more than ٣٢ characters, and click Save"
button on the navigation bar ", the message bar will show "parameters set successfully".
Attention:
Access Point Name (APN) is mobile operator to provide users with different access network
types; you must query the APN name from the local operator, and then modify the APN
name on the ACTM, so ACTM will able to connect to local GPRS network.
Username
Login GPRS service username, usually empty
Password
Login GPRS service password, usually empty
B. RTU Connection Setting
Click the left mouse button on "RTU Setting"; enter to the RTU connection setting, the
picture shown as below:
٣٣
34. GPRS/SMS ACTM User manual
Band
Serial port configuration, selectable baud rate is ٣٠٠-١١٥٢٠٠.
Attention:
This band is same band with configuration software connect to ACTM, if you modify this
band rate, simultaneously modify configuration band, then the configuration software able
to connect the ACTM.
Data bit
Serial port configuration, data bits is ٨-bit usually
Stop bit
Serial port configuration, usually is ١ stop bit
Parity bit
Serial port configuration, parity bit is NONE usually
Data packet interval
١٠٠-٢٠٠٠ms, RTU Packet Minimum time interval, the default is 300ms
Customized RTU Command
ACTM can end command to RTU automatically, command is hex code, no space between
commands, for example: the command is ٥٥ ٤٥ ٠٠ ٠١ ٠٠ ٢٣, so just fill in as ٥٥٤٥٠٠٠١٠٠٢٣
Data Header
Add data head on sending RTU data to center; Format: ID(Max ١٦ byte ASCII
code)@time,date(٦ byte, HEX format)@ data (hex code)
Command Interval
Interval for sending RTU commands within group
Group commands Interval
Interval for sending RTU commands between groups
SMS RTU
At the SMS mode, ACTM can forward RTU data via SMS to the data center and
pass-through SMS data from data center to the RTU seires port
C. IP Channel Setting
٣٤
35. GPRS/SMS ACTM User manual
The Parameter is for ACTM work on TCP/UDP mode; click the left mouse on"IP Channel";
enter to the IP parameter setting, the picture shown as below:
Main IP address
x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center
through domain name.
Main Domain Name
Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM
will analysis domain name to be IP address, then using the IP address to connect data
center.
Main Port
١-٦٥٥٣٥, Main data center IP port
Backup IP address
x.x.x.x, Backup data center IP address. if ACTM cannot connect to main IP address many
times, ACTM will try to connect backup IP address.
Backup Domain Name
Backup data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠;
ACTM will analysis domain name to be IP address, then using the IP address to connect
data center.
Backup Port
١-٦٥٥٣٥, Backup Data center IP port.
Heartbeat Interval
٠-٦٥٥٣٥ Seconds, Heartbeat interval, if value is 0, ACTM will don’t send heartbeat data.
The default interval is 40 seconds.
The heartbeat is link maintain parameter, that is the heartbeat interval, ACTM periodically
sends the fixed format of heartbeat packets to data center, which has maintained a link
connection. This is because the network operators in order to prevent terminals linked to
the Internet, but don't transferring data, taking the wireless network resources, as found
in the terminal does not transmit data within a certain period of time, it will kick off the
assembly line to the terminal.
Work mode
٣٥
36. GPRS/SMS ACTM User manual
GPRS transmission work mode, IO protocol mode will send&receive data through Arian
protocol, and it use for connect ACTM management platform; transparent mode, using the
transparent data channel, and sends heartbeat packets, it’s for connect to other platform
or data center.
Sleep Mode
For save GPRS data transmission, ACTM provide 2 kinds of online solution; always online,
ACTM will online GPRS all the time; Sleep mode, ACTM will wait for specified time, if there
is no alarm and no data transmission, GPRS will automatically be offline, however, it can be
activated by SMS or ring
Offline interval
٠-٦٥٥٣٥ Seconds, ACTM offline waiting time, the default is 300 seconds.
Reconnection Interval
٠-٦٥٥٣٥Seconds, IP channel failure or reconnect after sleep time interval, if set to ٠, ACTM
will don't try re-connect, only wake-up can make ACTM on-line, the default value is 300
seconds.
A group of the number of re-connect
一Set to ٠, no change to backup channel, only try to connect the main channel
A group of reconnection interval
一A group of reconnection interval, Seconds
Two groups of reconnection interval
Two groups of reconnection interval, Minute!!! The default is 10 minutes.
Login attempt times
Set as ٠, ACTM only send a registration packet once, Data center is not neccessary to reply
registration ACK package; ١ to ١٠, Data centers must respond to the registration ACK
package, otherwisem, ACTM will disconnect and reconnect
Heartbeat ACK
According to the GPRS signal unstab area, we can enable the heartbeat ACK function. If
ACTM did not receive heartbeat ACK packets from data center as ٣ times, ACTM will
disconnect the link and try to reconnect.
SMS Backup
For the GPRS network often abnormal area, we can enable SMS backup function, when the
GPRS link is disconnect, ACTM will also send a message via SMS to the data center; When
GPRS recovery, ACTM will send this information to the data center again.
D. SMS Channel Setting
The parameter is for ACTM work on SMS mode, click the left mouse button on "SMS
Channel "; enter to the SMS Channel parameter setting, the picture shown as below:
٣٦
37. GPRS/SMS ACTM User manual
Service Number
For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please add country code on the front,
the number is for receive alarm SMS from ACTM, and remote control ACTM through SMS.
Service Number Mode
The Service number supports 4 modes:
Alarm mode, this number only receive alarm SMS, but it can not using SMS for remote
settings ACTM.
Alarm+Config mode, ACTM send alarm SMS to this number, the number can be remote
control ACTM as well.
Config mode, this number only for remote config ACTM, it cannot receive alarm SMS.
Administrator mode: This number supports Alarm + SMS all functionality, and receive all
arm and disarm information via SMS.
Daily report
٠٠:٠٠-٢٣:٥٩, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable.
Report at specified intervals
٠٠:٠٠-٢٣:٥٩, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable
Alarm Mode
For real time inform user about alarm, ACTM support 3 kinds of alarm mode. SMS mode,
ACTM only send alarm SMS; Ring mode, ACTM only Ring; SMS+Ring mode, ACTM will ring
for ٦٠ seconds, then send alarm SMS.
SMS Alarm Content
For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the
alarm happen, ACTM will send the pre-set SMS to service number. customize mode, ACTM
will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send alarm
SMS according Arian protocol
E. I/O Port Setting
The parameter is for ACTM I/O port setting, click the left mouse button on "I/O port
setting"; enter to the I/O parameter setting, the picture shown as below:
٣٧
38. GPRS/SMS ACTM User manual
Attention:
Configuration software can set ACTM-9220 and ACTM-9220 product parameter,
ACTM-9220 provide 3 DI, 1 AI, 1 DO, 2 TE ports, ACTM-9220 provide 7 DI, 4 AI, 4DO, 2
TE Ports. When set the ACTM-9220 I/O ports, just disable port alarm for DI4, DI5, DI6,
DI7, AI, 2, AI3 etc. if enable the not exist port alarm, there may be some illegal value, the
false alarms may happen.
DI Alarm Status
Low level, when port is low level, alarm happen;
High level, when port is high level, alarm happen;
Status change, when the port status change, alarm happen;
Pluse input, if connect to pluse input device, choose this option;
The default is Disable alarm.
DI Zone Type
Normal Zone: Start detect after arm immediately.
Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area.
Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for
PIR montion sensor, in case the wrong alarm.
Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for
connect to emergency button, smoke sensor etc.
Home Zone: This zone can be turning off by Home button of remote controller; when user
at home, he can use this function for disable some sensor inside home.
DI Zone Type
Normal Zone: Start detect after arm immediately.
Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area.
Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for
PIR montion sensor, in case the wrong alarm.
DI trigger duration
٣٨
39. GPRS/SMS ACTM User manual
Unit: ١٠٠ms, default value is ٢, so the duration is ٢٠٠ms. When DI port achieves alarm
value, and keeps after specified duration, occur alarm. According to part of senors (such as
float level sensors, pressure sensors), the value may be hovering between alarm/normal, it
may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set
DI port trigger duration, if DI port at alarm state and exceeds specified duration, then
ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes.
DI Alarm Customize SMS
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message
content to the service number. For example: Warning, tower water level is low!
DI Alarm Clear Customize SMS
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear
message content to the service number. For example: Warning, tower water level return to
normal!
Attention:
All customize SMS content can not include a comma, the comma as a parameter separator
that can not be used as a custom SMS content, we have to use other symbols instead of
comma.
WI Zone Type
Close Zone: Close this wireless zone.
Normal Zone: Start detect after arm immediately.
Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area.
Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for
PIR montion sensor, in case the wrong alarm.
Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for
connect to emergency button, smoke sensor etc.
Home Zone: This zone can be turning off by Home button of remote controller; when user
at home, he can use this function for disable some sensor inside home.
WI Alarm Customize SMS
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message
content to the service number. For example: Warning, detect people come in!
Notice:
Here is set wireless sensor WI zone types and customize SMS content, for using a wireless
sensor, you must first register wireless sensors, according the wireless sensor registration,
please refer to the "Wireless parameter setting".
Wireless sensor online detect period
The Default value is OFF detect function; all of Arian wireless sensor/detector products
support online detection function, the sensor sends online informatoin to ACTM about
every ٣ hours, ACTM recieve online information that means sensor is online; if ACTM didn't
received sensor online information for long time that means sensor already disconnect,
ACTM will occur sensor disconnect alarm. The detection time can be set to ٨, ١٦, ٢٤ to ٩٦
hours, in order to avoid false alarms, we can choose the appropriate online detection
period or OFF detection function.
AI Alarm Status
This is AI port Upper&Lower voltage value, ٣٣٠ is ٣.٣V, For example: ١٠٠~٢١٠, when AI
port voltage Lower than ١V, lower limit alarm happen; when higher than ٢.١V, Upper limit
alarm. Value is 0~0 is disable AI port alarm.
٣٩
40. GPRS/SMS ACTM User manual
Notice:
To prevent fluctuations in the value of AI interfaces to occur repeated alarm, when the AI
interface value beyond the scope of the directive over the value of +10, ACTM will occur
alarm, when the AI interface value back to the normal range -10, ACTM will occur alarm
clear. This value can be set through”AI Port alarm Accuracy”.
For example: set value as 100~210, so when the AI port value to be 90 or 220, ACTM will
occur alarm, when the temperature return to 110 or 200, ACTM will occur alarm clear.
AI trigger duration
Unit: ١٠٠ms, default value is 1, so the duration is 1٠٠ms. When AI port achieves alarm
value, and keeps after specified duration, occur alarm. According to part of senors (such as
voltage sensors, current sensors), the value may be hovering between alarm/normal, it
may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set
AI port trigger duration, if AI port at alarm state and exceeds specified duration, then
ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes.
AI Alarm Customize SMS
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message
content to the service number. For example: Warning, water pressure exceeds the limit!
AI Alarm Clear Customize SMS
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear
message content to the service number. For example: Warning, water pressure return to
normal!
AI Port alarm Accuracy
The current value is greater than or lower than the set alarm value and more than the
accuracy value, alarm hapeen.
TE Temperature Alarm Status
This value is the temperature of the upper and lower limits, the units is ℃. For example:
-5~28, when the temperature is lower than -5℃ or higher than 28℃, the alarm will occur;
When the temperature returned to normal, the alarm clear will occur. 0~0 is disable TE
port alarm.
Notice:
To prevent fluctuations in the value of TE temperature to occur repeated alarm, when the
temperature value beyond the scope of the directive over the value of +1, ACTM will occur
alarm, when the AI interface value back to the normal range -1, ACTM will occur alarm
clear.
For example: set value as -5~28, so when the temperature to be -6 or 29, ACTM will occur
alarm, when the temperature return to -4 or 27, ACTM will occur alarm clear.
TE trigger duration
Unit: ١s, default value is 1, so the duration is 1 second. When TE port temperature
achieves alarm value, and keeps after specified duration, ACTM will occur alarm. According
to temperature value may be hovering between alarm/normal, it may occur repeat
alarm/alarm clear information, disturb user to determine. ACTM can set TE port trigger
duration, if TE port at alarm state and exceeds specified duration, then ACTM will occur
alarm. For example: the trigger duration set to ٣٠٠, so that's ٥ minutes.
TE Temperature Alarm Customize SMS
The string length is not longer than 40, when the alarm occurs; send this alarm message
content to the service number. For example: Warning temperature is too low!
TE Temperature Alarm Clear Customize SMS
٤٠
41. GPRS/SMS ACTM User manual
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear
message content to the service number. For example: Warning clear, temperature return
to normal!
Attention:
ACTM provides two kinds of temperature, TE1 is external digital temperature interface, it
connects to extend temperature sensor, high accuracy. TE2 is embedded NTC temperature
sensor, it’s for test environment and ACTM device temperature.
DO Output
Control DO output, When DO output mode as High or Low level mode, choose high or low
level the default is low level; the DO port output voltage is same as Vin PIN voltage.; When
the DO output mode as programming mode, choose the high level to trigger the
implementation of the programmatic output, after the implementation returns an
unavailable level.
DO Output Mode
ACTM DO port support 2 mode, High or Low Level Mode,output as High or Low Level
simply; Program Modem,output as programming level
DO Output Program
Example: 1,1,2,3,2,00:00:00; 1 is Port;1 is avaiable level,high or low; 2 is available level
time period (Second); ٣ is unavailable level time period (Second); ٢ is cycle times; ٠٠:٠٠:٠٠
not implement as daily
Notice:
ACTM DO (digital output) port supports programmable output, according to the
requirement of user site, the level of output level, switching time, times would be
programmable. Please contact Arian technical engineer for instruction detail.
DO output link alarm
When alarm trigger, link to DO output.
DO Output Link Program
DO output the alarm link trigger port, type in the port name DI,TE,AI,WI (DI behalf of all
DI port, DI١ specifically DI١ port only)
DO Smart Link
For example: ٢,٦٠; ٢ times the specified port alarm within ٦٠ seconds, DO trigger output
Power Status Detect
Detect external power status, if the external power disconnect, ACTM will send alarm SMS
to service number. The default is ON.
Alarm Clear Message
Set as ON, if detect port alarm clear, ACTM will send alarm clear message.
F. Wireless Parameter Setting
The parameter is for register wireless sensor, click the left mouse button on "Wireless";
enter to the Wireless parameter setting, the picture shown as below:
٤١
42. GPRS/SMS ACTM User manual
Notice:
All wireless sensors must be registered on use wireless zones of the ACTM, and then it can
be used.
Wireless Zone
Zone: WI١ to WI٨ zones, each zone can be registered ٥ wireless sensors.
Registrater: wireless sensor registerion, after choose the zone, click "Register", ACTM into
the registration status, the information bar will prompt: Registratring ..., you need to take
the wireless sensor to send an alarm signal (through Tamper button or alarm), when ACTM
received this signal, you will heard "TA", it means sensor register successful.
Cancel: click "Cancel" to cancel the current registration.
Delete: select zone, then click "delete", it will delete the entire sensor on specified wireless
zones.
Delete All: click "Delete all", it will delete all wireless sensor from all zones.
Remoter
Function: Arm, Disarm, Home button; total 3 remoter buttons, each button can be
registerd for 5 remoter, it means each ACTM support max 5 remoter.
Registrater: after choose the function button; click "Register", ACTM into the registration
status, the information bar will prompt: Registratring ..., you need to push the button the
remoter, and you will hear "TA" from ACTM, it means register successful.
Cancel: click "Cancel" to cancel the current registration.
Delete: select function button, then click "delete", it will delete the entire funmciton button
of all remoter.
Delete All: click "Delete all", it will delete all remoter on the all function buttons.
Notice:
Wireless sensor support tamper switch, low battery, link disconnect alarm, when ACTM
disconnect link with sensors more than ١٦ hours, the disconnect sensor alarm will happen.
٤٢
43. GPRS/SMS ACTM User manual
After click the "Register" button, ACTM must receive the sensor signal within ٣ minutes;
otherwise, ACTM will exit from register status.
G. LED Screen Parameter Setting
At the SMS Mode, ACTM can connect an LED Screen, the parameter is for LED Screen
setting, , click the left mouse button on "LED Para."; enter to the LED parameter setting,
the picture shown as below:
LED Screen
At SMS mode, whether turn ON the LED screen function, when an alarm is occured, ACTM
will send the alarm customize SMS content to the LED screen. if ACTM didn't connect with
LED screen, turn OFFthis function.
Attention:
At GPRS communication mode, this option should be turned off. Data center platform will
control the LED display via GPRS directly, it don't need ACTM to control.
٤٣
Window Number
Send alarm information to the specified window number of LED screen
Display Time
Alarm information display time period, ٠ to ٦٥٥٣٥ seconds, value ٠ is always show
Effects coding
Alarm information display effects coding
Alignment
Alarm information display Alignment
Display Speed
Alarm information display speed, from ٠ to ١٠٠, the smaller the value are more faster
Stay time
Alarm information display stay time
Font color
44. GPRS/SMS ACTM User manual
Alarm information display font color
Font Size
Alarm information display font size
H. Run Setting
The parameter is for ACTM run setting, click the left mouse button on "Run Setting"; enter
to the Run parameter setting, the picture shown as below:
ACTM ID
Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be
location name, owner name, cell phone number etc. we recommend to be SIM card
number, and record the ID. The valuable range is 1~32 bytes.
Display Debug Info
Debug information is use for engineer solve the problem, usually, it should be OFF.
Attention:
If turn on the debug information, the configuring software may predictable behavior during
read/write ACTM parameters, then we should turn off debug information, and re-connect
ACTM.
Enable Camera
ACTM supports remote image capture function, connected through the RS٢٣٢ interface
with the camera, when ACTM connects with camera; you need to turn this option ON.
ACTM Communication Mode
ACTM support 5 mode to communication with center:
TCP mode, ACTM communication with data center via GPRS, and establish TCP connection
with data center.
UDP mode, ACTM communication with data center via GPRS, and establish UDP connection
with data center.
SMS mode, ACTM sends the alarm information via SMS to the service center number.
٤٤
45. GPRS/SMS ACTM User manual
TCP + SMS mode, ACTM communicate with data center via GPRS , and establish TCP
connection with data centers; but also support SMS functions, when alarm generated,
ACTM will send alarm information through GPRS and SMS at same time. At the applicaiton,
GPRS for data center, SMS end user to receive alarm at real time.
UDP + SMS, ACTM communicate with data center via GPRS , and establish UDP connection
with data centers; but also support SMS functions, when alarm generated, ACTM will send
alarm information through GPRS and SMS at same time. At the applicaiton, GPRS for data
center, SMS end user to receive alarm at real time.
Config Password
Using ACTM Configuration software to set up ACTM, it need password. Please enter new
password. The default value is 000000。
Attention:
Please do not change the configuration password, if the password is incorrect, you will not
able to set ACTM through configuration software.
If you forget password, you can enter to the serial window, enter the command "at +
ACTMdefault" to restore the default parameter, the password will restore the initial value
of ٠٠٠٠٠٠.
Buzzer
ON/OFF ACTM embedded buzzer
Defence Status
Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM
only monitor I/O status, but do not send alarm SMS. The default is not defence.
Notice:
From turn ON Defence, ACTM will enter defence status after ١٠ seconds.
ACTM supports alias name to SMS to ARM/DISARM, the user just simply type in arm or
disarm by the service center number. The command "at+defence=١" alias name is "arm";
the command "at+defense=٠" alias name is "disarm".
Timing Arm
Executive ARM at the specified time daily.
Timing Arm
Executive disarm at the specified time daily.
Password Disarm or Arm
Any mobile phone can send SMS+password to remote disarm/arm, it can be set to
maximum of ١٠ password, separated by commas. The default password is *, it means
none.
For example: send SMS”at+defence=1,123456” the 123456 is password, 1 means arm, 0
means disarm.
Notice:
This function is use for remote arm/disarm, if there is people who wanna enter to the area,
he can send password to arm/disarm. After SMS command send successful, ACTM will
return an sucssful SMS, and send copy to the administrator phone.
RFID/Alarm Resend Times
For data center to receive all the alarm, ACTM can set resend alarm times, value is
0-65535. GPRS mode: ACTM resend alarm packet times if didn't receive center alarm ACK
packet; SMS mode: ACTM resend alarm SMS times if didn't receive cellphone alarm ACK
SMS.
٤٥
46. GPRS/SMS ACTM User manual
Notice:
Set value as non ٠, the functional will effect. At the SMS mode, service number received
alarm SMS should reply ACK SMS to the ACTM, otherwise ACTM will resend alarm SMS.
There is a serial number for each alarm SMS, service number should reply ACK SMS as
format: ACK - serial number, for example: ACK -١٢, service number reply ACTM that
receives the serial number ١٢ alarm SMS.
RFID/Alarm Resend Interval
٠-٦٥٥٣٥ Seconds, ACTM resend alarm data packet interval if do not receive alarm ACK
(Include GPRS and SMS)
Continue Alarm Interval
٠-٦٥٥٣٥ Seconds, When more than one alarm occurs, the time interval between continue
alarm
I. System Parameter
ACTM system information, the option is only for query, it cannot be modify; click the left
mouse button on "System"; enter to the system information, the picture shown as below:
٤٦
Manufacturer Name
The default is Arian Ertebat Caspian Co. The Parameter is only for view.
Product Model
The default value is ET٨٠٠٠ GPRS/SMS ACTM,The Parameter is only for view.
Software Version
ACTM software version, The Parameter is only for view.
Hardware Version
ACTM hardware version, The Parameter is only for view.
Config Tool Version
Config Tool Version, The Parameter is only for view.
Product SN
ACTM product SN, the Parameter is only for view.
Product Number
47. GPRS/SMS ACTM User manual
٤٧
ACTM product number, The Parameter is only for view.
IMEI Number
ACTM IMEI Number, The Parameter is only for view.
48. GPRS/SMS ACTM User manual
٤٨
Chapter 5 Typical Application
This chapter describes in detail about ACTM typical application, by reading
this chapter, the reader should be able to know choose suitable mode and set up
ACTM.
١. SMS alarm application
٢. ACTM management platform application
٣. Transparent data transmission application
٥.١ SMS alarm application
For a small number of sites, SMS time delay is acceptable, simple operation, easy
maintenance project, we recommended using SMS mode, the user can remote monitoring
system through mobile phone, when an alarm occurred, ACTM will send SMS to mobile
phone, according to alarm, the user can send commands directly control ACTM. The
detailed SMS command instructions please check the attachment.
Set ACTM to SMS mode that needs to configure the following parameters:
Service Number
For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please pay attention to add country code
on the front, the number is for receive alarm SMS from ACTM, and remote control ACTM
through SMS.
You can set up max four service center number. and must be set to at least one central
number to take SMS mode effect.
SMS Alarm Content
For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the
alarm happen, ACTM will send the pre-set SMS to service number. Customize SMS mode,
ACTM will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send
alarm SMS according Arian protocol
Pre-set customize SMS is more easy to read alarm information, we recommend using a
customize SMS.
DI Alarm Status
Low level, when port is low level, alarm happen; High level, when port is high level, alarm
happen ;Status Change, when the port status change, alarm happen. The default is
Disable alarm.
49. GPRS/SMS ACTM User manual
According to the actual situation, set the I/O port alarm status, we only make example on
DI port, please set AI and TE port alarm status at same.
DI Alarm Customize SMS
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message
content to the service number. For example: Warning, tower water level is low!
DI Alarm Clear Customize SMS
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear
message content to the service number. For example: Warning, tower water level return to
normal!
ACTM ID
Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be
location name, owner name, cell phone number etc. we recommend to be SIM card
number, and record the ID. The valuable range is 1~32 bytes.
ACTM Communication Mode
ACTM communication with center mode; SMS mode, ACTM using SMS to communication
with service number; TCP and UDP mode, ACTM using GPRS to communication with data
service center.
It must be set as SMS mode.
Defence Status
Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM
only monitor I/O status, but do not send alarm SMS. The default is not defence.
It must be set as Defence status, so ACTM can monitor I/O port, and send alarm SMS.
Attention:
ACTM has a clock function, and using SMS to synchronization time, power up on ACTM for
the first time, please send "Timecal" SMS to ACTM through mobile phone, then ACTM will
reply "ACTM OK". Just set up once, ACTM will always using the clock running. For the
command detail, please check Chapter ٧.
Notice:
After setting these parameters, we need to restart ACTM to take function effect.
According the sensor installation, please check Chapter ٣ Installation.
٥.٢ ACTM management platform application
For more sites, complicated network, real-time is necessary, alarm history project, we
recommend using ACTM management platform. ACTM management platform through the
SQL database to save all alarm history, it's easy to use, and able to export excel report;
through GOOGLE map to showing the location of all site, when an alarm occurs, the alarm
immediately show red alarm logo on the map; with B/S structure, the user can
management all device at anywhere where just open browser; multi-level permissions can
be set to view and manage permissions, for normal users can only able to view, cannot
operation. Below picture shown ACTM management platform software, more information
please check Arian website.
٤٩
50. GPRS/SMS ACTM User manual
Set ACTM to connect ACTM management platform mode that needs to configure the
following parameters:
APN Name (APN)
Follow the prompts to enter information into the access point name (access point name
cannot be empty), enter the characters that not more than ٣٢ characters, and click Save"
button on the navigation bar ", the message bar will show "parameters set successfully".
According to different operator, enter to the correct APN name.
Main IP address
x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center
through domain name.
Main Domain Name
Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM
will analysis domain name to be IP address, then using the IP address to connect data
center.
Notice:
The main IP address and main domain name must be input, if else, ACTM will not able to
communication with ACTM platform.
Main Port
١-٦٥٥٣٥, Main data center IP port
Work mode
GPRS transmission work mode, IO protocol mode will send&receive data through Arian
protocol, and it use for connect ACTM management platform; transparent mode, using the
٥٠
51. GPRS/SMS ACTM User manual
transparent data channel, and sends heartbeat packets, it’s for connect to other platform
or data center.
It must be set as IO protocol mode, so ACTM will use Arian communication protocol to
connect with ACTM platform.
DI Alarm Status
Low level, when port is low level, alarm happen; High level, when port is high level, alarm
happen ;Status Change, when the port status change, alarm happen. The default is
Disable alarm.
According to the actual situation, set the I/O port alarm status, we only make example on
DI port, please set AI and TE port alarm status at same.
ACTM Communication Mode
ACTM communication with center mode; SMS mode, ACTM using SMS to communication
with service number; TCP and UDP mode, ACTM using GPRS to communication with data
service center.
It must be set as TCP or UDP mode.
Defence Status
Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM
only monitor I/O status, but do not send alarm SMS. The default is not defence.
It must be set as Defence status, so ACTM can monitor I/O port, and send alarm
information.
Notice:
After setting these parameters, we need to restart ACTM to take function effect.
According the sensor installation, please check Chapter ٣ Installation.
٥.٣ Transparent data transmission application
As RTU and PLC which provide RS٢٣٢ interface, ACTM provides RS٢٣٢ interface to connect
with RTU and PLC, using transparent data channel that send RTU data to data center. Data
center can use the RTU software or data center platform to receive ACTM+RTU data.
Set ACTM to transparent data transmission mode that needs to configure the following
APN Name (APN)
Follow the prompts to enter information into the access point name (access point name
cannot be empty), enter the characters that not more than ٣٢ characters, and click Save"
button on the navigation bar ", the message bar will show "parameters set successfully".
According to different operator, enter to the correct APN name.
Band
Serial port configuration, selectable baud rate is ٣٠٠-١١٥٢٠٠.
Attention:
٥١
52. GPRS/SMS ACTM User manual
This band is same band with configuration software connect to ACTM, if you modify this
band rate, simultaneously modify configuration band, then the configuration software able
to connect the ACTM.
Main IP address
x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center
through domain name.
Main Domain Name
Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM
will analysis domain name to be IP address, then using the IP address to connect data
center.
Notice:
The main IP address and main domain name must be input, if else, ACTM will not able to
communication with ACTM platform.
Main Port
١-٦٥٥٣٥, Main data center IP port
Work mode
GPRS transmission work mode, IO protocol mode will send&receive data through Arian
protocol, and it use for connect ACTM management platform; transparent mode, using the
transparent data channel, and sends heartbeat packets, it’s for connect to other platform
or data center.
It should be set as transparent mode usually, ACTM will use transparent channel to
connect with data center. If the data center use Arian ACTM management platform while
using the RTU, then select IO protocol mode.
ACTM Communication Mode
ACTM communication with center mode; SMS mode, ACTM using SMS to communication
with service number; TCP and UDP mode, ACTM using GPRS to communication with data
service center.
It must be set as TCP or UDP mode.
Notice:
After setting these parameters, we need to restart ACTM to take function effect.
According the sensor installation, please check Chapter ٣ Installation.
ACTM provides storage and forwarding the command functions of the MODBUS protocol,
users can pre-save the common command to ACTM, and ACTM will send the command
PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically. Please contanct
Arian technical engineer for instruction detail.
٥٢
53. GPRS/SMS ACTM User manual
٥٣
Chapter 6 Operation
This chapter describes in detail about ACTM operation and troubles shooting,
by reading this chapter, the reader should be able to solve general ACTM
problem.
١. Panel Indications
٢. ACTM operation Guidance
٣. Trouble Shooting
٦.١ Panel Indications
There are four LEDs at ACTM-9220 ACTM front panel; it indicates the ACTM network,
operation and alarm status.
The below form is the LED indicators description:
Status Sub-Status PWR NET DATA ALM
Initial
state
Initialing Lights Up Lights Down Lights Up
Check SIM Lights Up 1 Second Flash Lights Down
GPRS Dial up Lights Up Lights Down 0.3 Second
Flash
GPRS registing Lights Up 0.3 Second
Flash
Lights Down
Connecting to
Data center
Lights Up 0.3 Second
Flash
0.3 Second
Flash
Work
state
GPRS Standby
(Sleep)
Lights Up Lights Down 5 Second
Flash
GPRS/SMS work
status
Lights Up According the
Signal strength
to flash
Flash on
data
transmission
Light Up at
battery power,
flash at alarm
happen
Notice:
After ACTM work well, the NET indicator will blink according to the signal strength, ACTM
will query signal strength per minute.
CSQ Signal strength in the ٠١-١٢, very fast flash;
CSQ signal strength in the ٠٣-١٨, fast blinking;
CSQ signal strength in the ١٩-٣١, slow blinking;
After ACTM work well, PWR indicator will light up, DATA and NET indicator will light up for
2 seconds and light down for 2 seconds.
ALM indicator and buzzer that there is alarm occur, it will buzz or blink. When ACTM switch
to battery power, the ALM LED will light UP.
54. GPRS/SMS ACTM User manual
٥٤
٦.٢ ACTM operation Guidance
ACTM is an intelligent wireless data terminal; after installation and setting, just connect
sensor and power, then it will work well.
ACTM should be installed at place with good radio signal receiving. For the cabinet and
basement environment, we recommend to extend the antenna.
Warning:
For outdoor use, lightning should be considered. We propose to install an arrester between
antenna and the ANT interface. Contact Arian technical support department for details.
No routine maintenance is required for ACTM operation. At embedded application
environment, the data service center will check ACTM operation information.
٦.٣ Trouble Shooting
Problem ١: All LEDs do not light up.
Check all cables that are connected to the ACTM.
Check the power supply adapter output voltage.
If the power is correctly connected and there is no LED that light up, the ACTM may be
failed. Contact to Arian or reseller for repairing.
Problem 2: Instability after working long time.
Please check whether the device is overheating, if overheated, put device into place in
order to facilitate ventilation and cooling equipment.
Problem 3: Using the configuration software to connect ACTM, but always unsuccessful.
It needs to select the correct serial port and rate to connect ACTM, the default rate is
١١٥٢٠٠.
Attention:
if use of USB-RS٢٣٢ converter cable to connect ACTM, please use Arian configuration
cable. If use other brand of USB converter cable, please pay attention to buy high-quality
cable, there is many bad-quality cable on the market, it may occur many problem to
connect. In addition, PC's serial port is very easy to down, sometimes, you need to restart
PC, and then try to connect.
Problem 4: I have already connected the sensor, set the port alarm status, but when an
alarm is occurred, ACTM did not send the alarm information.
Please check to set ACTM defence to be "defence" status, after set to "defence" status that
wait for ١٠ seconds, ACTM will start monitor I/O port status.
Problem 5: I'm using the configuration software, and already connect to ACTM successful,
but when I query/save parameter, it show query/save failed, so I cannot config parameter.
ACTM in without cards or GPRS connection mode, it may automatically restart after
connect ACTM unsuccessful, when you open the configuration software for while, it show
errors, so ACTM may be restarted, then just click "connect" button, configuration software
55. GPRS/SMS ACTM User manual
will try to connect ACTM again. Now, try to query/save parameter that will be successful.
We suggest insert SIM first then set up ACTM.
Problem 6:
I'm using the configuration software, but there is many parameters are illegal value.
The reason that's open the debugging information, ACTM debug information is large
amount of data; it may affect configuration software to read/write parameter from ACTM
sometimes. so please turn OFF the ACTM debug information then using the configuration
software.
Problem 7: ACTM shows ٤ lights flashing simultaneously, buzzer alarms fast flash, data
cannot communication.
This problem is ACTM internal battery will be no power soon. Please check the external
power supply, and the power cord, you can check it on the ١٢PIN terminal.
Problem 8: I connected ١٢V relay to ACTM DO port, set DO port output as high lever
through configuration software, but the relay didn't action.
DO port supply voltage is same Vin pin voltage, if using ١٢V relay, make sure the Vin pin
voltage is the same as ١٢V. also, check the external power supply, if external power lose,
ACTM will use internal battery, then DO only has ٣.٧V voltage, so relay will no action also.
Problem 9: After turn ON ACTM power, it display PWR, DATA, NET, ALM all are lights up,
and ACTM does not work.
٤ lights up means the ACTM is in the software upgrade status check the upgrade firmware
button on the configuration cable, just press the button, and restart the ACTM, ACTM will
return to normal mode.
Problem 10: ACTM buzzer sometimes occur a short "TA"sound.
This is normal, when ACTM is no signal or cannot connect to data center for many times, it
will automatically restart, the buzzer will occur short "TA" sound.
Problem 11: Set up ACTM service center number, but the number does not receive alarm
SMS.
Check the service center number is that fill in correct format, the numbers must add the
country code + or ٠٠ in the front, if doesn't fill in the country code or the + and ٠٠ doesn’t
in the front, ACTM may not able to send out SMS.
٥٥
56. GPRS/SMS ACTM User manual
٥٦
Chapter 7 Attachment SMS
Command
This chapter describes in detail about SMS command detail, by reading this
chapter, the reader should be able to how to remote control ACTM by SMS.
١. Introduction
٢. Command format
٣. Command list
٤. Command detail
٥. Alarm information format
٧.١ Introduction
ACTM SMS command list defines a format of SMS communication format, its use for ACTM
and the cell phone communication each other. Users should follow this document to the
remote control ACTM by SMS.
This command list applies to all ACTM products.
٧.٢ Command format
A. ACTM commands were signed by the command code, Parameter separator, parameters,
three major elements; multiple parameters can be composed of the parameter list.
Command total length should not exceed ٥٠ characters, if the command is too long, it can
be sent by multiple divided SMS.
Command Parameter separator Parameter, Parameter list
Command “=” ( Separator between command and
parameters)
“,”(Separator between Multiple parameters)
“?”(Enquiry symbol)
Parameter
Command=param1,param2,param3……..
Command?
Attention:
We must be set ACTM service number to be remote cell phone number, other phone
numbers send commands to the ACTM, ACTM will do not implement.
57. GPRS/SMS ACTM User manual
٥٧
٧.٣ Command list
Timecal
ACK
At+ACTMpsw
At+ACTMrst
At+transtype
At+ACTMid
At+almlvset
At+almlvread
At+almbat
At+defence
At+outctrl
At+inctrl
At+almclr
At+almpoint
At+almsect
At+servnum
At+servalm
At+almparam
At+almflag
At+mservip
At+bservip
At+mservname
At+bservname
At+sleepmode
At+conntry
At+miscintv
At+accinfo
٧.٤ Command detail
Command Timecal
Function SMS Clock synchronization command
Parameter None
MEMO This command only through SMS, it cannot implement by console port.
Example:
Timecal
Returns:
ACTM TIME CALIBRATION OK,2011/01/18-09:54:47
Command At+ACTMrst
Function ACTM reboot
Parameter None
MEMO There is no response SMS from ACTM, after send command, ACTM will
restart immediately.
Example:
At+ACTMrst
Returns:
Command At+transtype
Function ACTM with data center communication way
Parameter ? Query the command current value, example: At+transtype?
0 Using SMS for communication with service center cell phone
1 Using TCP for communication with data center
2 Using UDP for communication with data center
3 Using TCP+SMS for communication with data center
2 Using UDP+SMS for communication with data center
MEMO The default is 0,SMS mode
Example:
At+transtype=1
Returns:
transtype = ١
ACTM OK
Command At+ACTMid
58. GPRS/SMS ACTM User manual
Function ACTM ID (it cannot exceed 32 letters), this ID is ACTM identify number,
٥٨
the service center to identify different SMS by this ID.
Parameter ? Query current command value, example: At+ACTMid?
ID Change ACTM ID to current value
MEMO
Example:
At+ACTMid=SHENZHEN
At+ACTMid?
Returns:
ACTM ID:SHENZHEN
ACTM OK
Command At+almlvset
Function Set I/O port alarm level
Parameter Para1, para2, para3
Para1 port name, it is DI,AI,TE
Para2 port number, it is 1,2,3,4,5,6,7
Para3 port value:
DI port: value 0, disable alarm
value 1, low level alarm
value 2, high level alarm
value 3, the level status change alarm
AI port: Min*Max, when AI port current value exceed range above +10,
ACTM will occurred alarm, when AI port return to normal range -10,
ACTM will occurred alarm clear.
TE port: Min*Max, when TE port current value exceed range above +1,
ACTM will occurred alarm, when TE port return to normal range -1,
ACTM will occurred alarm clear.
MEMO
Example:
Set DI3 port high level alarm command is as below:
At+almlvset=DI,3,2
Set AI1 port minimum value to 0, Maximum value to 100:
At+almlvset=AI,1,0*100
Set TE1 port minimum value to -20, Maximum value to 70:
At+almlvset=TE,1,-20*70
Returns:
DI:٠x٠٠٠٠٠٠٢٠
ACTM OK
Command At+almlvread
Function Query IO port alarm value
Parameter Para1, para2
Para1 port name, it is DI, AI, TE, if there is no para2, the command will
query all of port name value.
Para2 port number, it is 1,2,3,4,5,6,7
MEMO
Example:
Query DI3 port alarm value:
At+almlvread=DI,3
Query all of AI port alarm value:
At+almlvread=AI
Query TE1 port alarm value:
At+almlvread=TE,1
59. GPRS/SMS ACTM User manual
٥٩
Returns:
DI(٠٣)LV=٢
ACTM OK
Command At+inctrl
Function Query current IO port status
Parameter Para1, para2
Para1 port name, it is DI, AI, TE, ALL; ALL will query all of Port value.
Para2 port number, it is 1,2,3,4,5,6,7
MEMO
Example:
Query DI3 port current value:
At+inctrl=DI,3
Query TE1 port current value:
At+inctrl=TE,1
Query ALL port current value:
At+inctrl=all
Returns:
٠,0,0,0,0,0,0,0
0,364,340,424
0,36
ACTM OK
MEMO:the first line of returns is DI port current value, the second line of returns is AI
port current value, the thired line of returns is TE port current value.
Command At+outctrl
Function Control DO port output high level or low level; High level: DC12V Low
level: 0V
Parameter ? Query DO port current output status, example: At+outctrl?
Para1, para2
Para1 DO port number, it is 1,2,3,4
Para2 port value, 0 is low level, 1 is high level.
MEMO Note: DO ports with memory function, if there is power-off, restart,
ACTM can automatically restore the previous settings of the state. But
there is always low level during ACTM boot.
Notice: If set At+almlink, the At+outctrl command will be unfunction,
the DO port will only control by port alarm.
Example:
Set DO1 port output high level
At+outctrl=1,1
Query DO port current output status
At+outctrl?
Returns:
DO:١,١,١,١
ACTM OK
Command At+almbat
Function Detect external power status
Parameter ? Query command current value, example: At+almbat?
0 ACTM do not detect external power status, not occurred alarm.
1 ACTM detects external power status, if there is change, ACTM will
occur alarm.
MEMO The default value is 1.
Example:
60. GPRS/SMS ACTM User manual
٦٠
Set detect external power status:
At+almbat=1
Returns:
power status check enable
ACTM OK
Command At+defence
Function Defence or not defence
Parameter ? Query current command value, example: At+defence?
٠ not defence, all IO ports are not in the surveillance state, that does
not occurred alarm information
١ defence all IO port are in the surveillance state.
MEMO The default value is 1.
Alias name "at+defence=١" alias name is "arm";
"at+defense=٠" alias name is "disarm".
Example:
Set ACTM defence
At+defence=1
Returns:
DEFENCE
ACTM OK
Command At+almclr
Function Alarm clear message
Parameter ? Query command current value, example: At+almclr?
٠ do not send alarm clear message
١ send alarm clear message
MEMO The default value is 1
Example:
Set ACTM send alarm clear message
At+almclr=1
Returns:
ON
ACTM OK
Command At+almpoint
Function Set ACTM report IO port status as appoint time everyday
Parameter ? Query command current value, example: At+almpoint?
Para1,Para2
Para1 0 disable function, 1 enable function
Para2 time format: hh:mm:ss
MEMO
Example:
Set everyday 12:30:15 report current IO port status
At+almpoint=1,١2:30:15
Returns:
auto send time point enable
ACTM OK
Command At+almsect
Function Set ACTM auto report IO port status as specify interval
Parameter ? Query command current value, example: At+almsect?
Para1,Para2
61. GPRS/SMS ACTM User manual
٦١
Para1 0 disable function, 1 enable function
Para2 Interval, the unit is second
MEMO
Example:
Set auto report interval as 8000 seconds
At+almsect=1,8000
Returns:
auto send interval enable
auto send interval:٨٠٠٠
ACTM OK
Command At+servnum
Function Set ACTM service center number
Parameter ? Query command current value, example: At+servnum? It will display
4 service center number
Para1,Para2
Para1 Service center number series number, it is 0,1,2,3
Para1 Service center number, any numbers.
MEMO Service center number is data center modem SIM card number or user
cell phone number; ACTM will send alarm SMS to this number, the max
number is 4.
Example:
Send the second service center number as 13812345678
At+servnum=1,13812345678
Returns:
to(١) :١٣٨١٢٣٤٥٦٧٨
ACTM OK
Command At+servalm
Function Set service center number receive alarm message
Parameter ? Query current value, example: At+servnum?
Para1,Para2,Para3,Para4
Para1 The first service center number receive alarm SMS, 0 is not
receive, 1 is receive
Para2 The second service center number receive alarm SMS, 0 is not
receive, 1 is receive
Para3 The third service center number receive alarm SMS, 0 is not
receive, 1 is receive
Para4 The fourth service center number receive alarm SMS, 0 is not
receive, 1 is receive
MEMO If set service center do not receive alarm SMS, so this number will only
remote configuration via SMS.
Example:
Set only the third service center number receive alarm SMS
At+servalm=0,0,1,0
Returns:
٠,٠,١,٠
ACTM OK
Command At+almparam
Function Set ACTM SMS alarm resend
Parameter ? Query current command value, example: At+almparam?
Para1,Para2,Para3
Para1 Set center number do not response ACK, the resend SMS
62. GPRS/SMS ACTM User manual
retransmissions, if set as 0, disable alarm SMS receipt function, so alarm
SMS will only send to center number once.
Para2 Set alarm SMS resend wait interval, the unit is second
Para3 Set continue alarm SMS interval, the unit is second
٦٢
MEMO
Example:
Set retransmissions to be 3, resend SMS interval to be 300 seconds
At+almparam=3,300,0
Returns:
٣,٣٠٠,٠
ACTM OK
Command ACK
Function SMS receipt, if enable ACK function, center service number should reply
ACK SMS when receive alarm SMS.
Parameter ٠٠1 ~ ٩٩٩ alarm SMS series number, all occurred alarm SMS has an
series number, Data center reply ACK with series number to inform
ACTM that receive which alarm SMS already.
MEMO This command is only available through SMS.
Example:
Data center send SMS receipt, alarm SMS series number is 001
ACK -٠٠١
Data center send SMS receipt, alarm SMS series number is 2
ACK -٢
Command At+almflag
Function Set GSM dial up center number and Buzz
Parameter ? Query command current value, example: At+almflag?
Para1,Para2
Para1 before send SMS alarm, ACTM will dial up center number to
inform alarm occurred. 0 disable function, 1 enable function.
Para2 Buzz, ٠ turn off buzz, 1 turn on buzz
MEMO GSM dial function default value is 0, Buzz default value is 0
Example:
Set alarm to ring service number, and turn on buzz
At+almflag =١,1
Returns:
wtt[٠] = ١
wtt[١] = ١
wtt[٠] = ١ wtt[١] = ١
ACTM OK
*Command At+mservip
Function Set main data center IP address, port
Parameter ? Query current command value, example: At+mservip?
Para1,Para2
Para1 Data center IP address, if using domain name, here should be
0.0.0.0
Para2 Port number
MEMO
Example:
Set main data center IP as 20.13.48.6, port as 5008
At+mservip=20.13.48.6,5008
Returns:
63. GPRS/SMS ACTM User manual
٦٣
ip = ٢٠.١٣.٤٨.٦
port = ٥٠٠٨
ACTM OK
*Command At+bservip
Function Set backup data center IP address, port
Parameter ? Query current command value, example:At+bservip?
Para1,Para2
Para1 Data center IP address, if using domain name, here should be
0.0.0.0
Para2 Port number
MEMO
Example:
Set backup data center IP as 10.23.48.6, port as 5007
At+bservip=10.23.48.6,5007
Returns:
ip = ١٠.٢٣.٤٨.٦
port = ٥٠٠٧
ACTM OK
*Command At+mservname
Function Set main domain name address
Parameter ? Query current command value, example:At+mservname?
Para1 Domain name, any character
MEMO
Example:
Set main domain name address as ACTM.Ariancn.com
At+mservname=ACTM.Ariancn.com
Returns:
server name = ACTM.Ariancn.com
ACTM OK
*Command At+bservname
Function Set backup domain name address
Parameter ? Query current command value, example:At+bservname?
Para1 Domain name, any character
MEMO
Example:
Set Backup domain name address as ACTM.Ariancn.com
At+bservname =ACTM.Ariancn.com
Returns:
server name = ACTM.Ariancn.com
ACTM OK
*Command At+sleepmode
Function ACTM sleep function
Parameter ? Query current command value, example:At+sleepmode?
Para1,Para2
Para1 whether enable sleep function
Para2 the wait time for enter sleep status, the units is second.
MEMO Detected the specified time that without data transmission RS٢٣٢
interface, and no IO alarm occurred, ACTM will go to sleep. The default
is ٠, disable the sleep function
Example: