SlideShare a Scribd company logo
1 of 66
Download to read offline
١ 
ACTM User Manual 
Version 1.٠
GPRS/SMS ACTM User Manual 
٢ 
Notice: 
Copyright 
The contents of the manual are protected by Chinese law, any 
organization and/or person cannot copy this manual or part of contents 
without Arian Ertebat Caspian Co. authorization in written. 
Trademark 
ACTM, GPRS ACTM are the logos and trademarks of Arian Ertebat Caspian Co. 
The other company trademarks and logos in this manual are owned by the 
owner, Arian does not have the right for those trademarks and logos.
GPRS/SMS FAM User manual 
٣ 
Contents 
CHAPTER ١ INTRODUCTION ........................................................................................................... ٥ 
١.١ Objective ..................................................................................................................................................................... ٥ 
١.٢ Application ................................................................................................................................................................. ٥ 
١.٣ Version......................................................................................................................................................................... ٥ 
١.٤ Convention ................................................................................................................................................................. ٦ 
١.٥ Technical Support ................................................................................................................................................... ٦ 
١.٦ Abbreviations ........................................................................................................................................................... ٧ 
CHAPTER ٢ PRODUCT INTRODUCTION .................................................................................. ١٠ 
٢.١ Introduction ............................................................................................................................................................ ١٠ 
٢.١.١ Size ............................................................................................................................................................................. ١١ 
٢.١.٢ Accessories ............................................................................................................................................................ ١٢ 
٢.٢ System function and feature ............................................................................................................................ ١٢ 
٢.٢.١ Main function ........................................................................................................................................................ ١٢ 
٢.٢.٢ Part of compatible sensor ............................................................................................................................... ١٤ 
٢.٣ Specification ............................................................................................................................................................ ١٥ 
CHAPTER ٣ INSTALLATION.......................................................................................................... ١٨ 
٣.١ ACTM installation and cable connection .................................................................................................... ١٨ 
٣.١.١ Antenna and SIM card installation .............................................................................................................. ١٨ 
٣.١.٢ RS٢٣٢ configuration and Power cables installation ............................................................................ ١٨ 
٣.٢ Sensors installation .............................................................................................................................................. ١٩ 
٣.٢.١ DI (Digital Input) sensor installation ......................................................................................................... ٢٠ 
٣.٢.٢ AI (Analog Input) Sensor installation ........................................................................................................ ٢١ 
٣.٢.٣ DO (Digital Output) device installation ..................................................................................................... ٢١ 
٣.٢.٤ TE (Temperature) sensor installation ....................................................................................................... ٢٢ 
٣.٢.٥ Wireless Sensor installation ........................................................................................................................... ٢٢ 
٣.٢.٦ Camera installation ............................................................................................................................................ ٢٢ 
٣.٢.٧ RTU device installation .................................................................................................................................... ٢٣ 
٣.٣ Grounding ................................................................................................................................................................ ٢٤ 
٣.٤ Power supply .......................................................................................................................................................... ٢٤ 
٣.٥ Check the mobile network ................................................................................................................................ ٢٤ 
CHAPTER ٤ TERMINAL CONFIGURATION ............................................................................. ٢٦ 
٤.١ Device Connection ................................................................................................................................................ ٢٦ 
٤.٢ Parameter Configuration ................................................................................................................................... ٢٨
GPRS/SMS FAM User manual 
٤.٣ Parameter Detail ................................................................................................................................................... ٣٢ 
CHAPTER ٥ TYPICAL APPLICATION ......................................................................................... ٤٨ 
٥.١ SMS alarm application ........................................................................................................................................ ٤٨ 
٥.٢ ACTM management platform application .................................................................................................. ٤٩ 
٥.٣ Transparent data transmission application ............................................................................................. ٥١ 
CHAPTER ٦ OPERATION ................................................................................................................ ٥٣ 
٦.١ Panel Indications ................................................................................................................................................... ٥٣ 
٦.٢ ACTM operation Guidance ................................................................................................................................ ٥٤ 
٦.٣ Trouble Shooting .................................................................................................................................................. ٥٤ 
CHAPTER ٧ ATTACHMENT SMS COMMAND ......................................................................... ٥٦ 
٧.١ Introduction ............................................................................................................................................................ ٥٦ 
٧.٢ Command format .................................................................................................................................................. ٥٦ 
٧.٣ Command list .......................................................................................................................................................... ٥٧ 
٧.٤ Command detail .................................................................................................................................................... ٥٧ 
٧.٥ Alarm information format ................................................................................................................................ ٦٥ 
٤
GPRS/SMS FAM User manual 
٥ 
Chapter ١ Introduction 
This chapter describes the manual functions and role, also tells the reader how to 
read the manual, it's best guidance document for install and use Arian 
GRPS/SMS ACTM. 
١. Objective 
٢. Application 
٣. Version 
٤. Convention 
٥. Technical Support 
٦. Abbreviations 
١.١ Objective 
This manual mainly ACTM-٩٢٢٠ Quick Start Guide for reference that written to 
guide ACTM-٩٢٢٠ ACTM installation products. 
١.٢ Application 
This manual applies to a certain computer communications networks, industrial 
automation control and electronic technical knowledge, network equipment, 
administrators, engineers and other industrial control which need to use 
ACTM-٩٢٢٠ ACTM that relevant managers. 
Applies to version: ACTM-٩٢٢٠ ACTM V١.٠ and below versions. 
١.٣ Version 
According to the market requirement, Arian ACTM-٩٢٢٠ ACTM product-related 
functions will be adjusted as well as technical improvements. Since the authors 
have a variety of reasons may cause the contents of revised instructions, the 
below table show Arian ACTM-٩٢٢٠ product specifications revised at different 
times and revised version of the reasons for that. 
Version Modify 
department 
Participating 
departments 
Date detail
GPRS/SMS FAM User manual 
٦ 
١.٤ Convention 
For ease of use, fast reading manual, we have some short name, icons, 
description, security alerts, tips and other conventions are as follows: 
Convention Description Memo 
ACTM-922 
0 
Arian ACTM-9220 GPRS/SMS 
ACTM 
Support ٣ DI, ١ AI, ١ DO 
ports 
ACTM-922 
0 
ET8600 series GPRS/SMS 
ACTM products 
Support ٧ D, 1 AI, ٤ DO 
ports, Support Wireless 
Sensor 
ACTM GRPS/SMS ACTM 
Suggestion Installation time-saving tips or 
experience 
Appear in this manual 
installation and testing 
Notice Prompt the user or reader to 
pay attention the important 
information or parameters 
Appear in this manual 
operation 
Warning A serious warning, such as the 
improper use of the 
temperatures, voltage, 
unstable environment 
Appear in this manual 
production introduction 
and installation 
Attention General warning: prompt the 
user some illegal operation or 
improper use of operations 
١.٥ Technical Support 
To allow users to quickly solve difficult problems, get the correct solution for 
hardware, operating system and installation. The following ways to contact Arian
GPRS/SMS FAM User manual 
٧ 
١.٦ Abbreviations 
The Manual related abbreviation meaning: 
APN Access Point Name 
APP Application 
ATM Asynchronous Transfer Mode 
ATM Auto Table Machine 
AuC Authentication Centre 
BG Border Gateway 
BGP Border Gateway Protocol 
BSC Base Station Controller 
BSCC Base Station Control Connection 
BSS Base Station System 
BSSGP BSS GPRS Protocol 
BTS Base Transceiver System 
CDMA Code Division Multiple Access 
CDR Call Detail Record 
CGF Charging Gateway Function 
CSD Circuit Switch Data 
DDN Digital Data Network 
DHCP Dynamic Host Configuration Protocol 
DNS Domain Name System 
DSC Data Service Center 
DTU Data Terminal Unit 
EGP External/Exterior Gateway Protocol 
EIGRP External/Exterior Internet Group Routing Protocol 
EMC Electro Magnetic Compatibility 
ESP Electro Static Precautions 
ETSI European Telecommunications Standards Institute 
GGSN Gateway GPRS Support Node 
GMSC Gateway MSC 
GPRS General Packet Radio Service 
GSM Global System for Mobile Communications 
GSN GPRS Support Node 
GTP GPRS Tunneling Protocol 
GTP-id GTP Identity 
ACTM Fixed Asset Monitor 
HLR Home Location Register 
HSCSD High Speed Circuit Switch Data
GPRS/SMS FAM User manual 
٨ 
IGMP Internet Group Management Protocol 
IGRP Internet Gateway Routing Protocol 
IN Intelligent Network 
IP Internet Protocol 
IPv٤ IP version ٤ 
IPv٦ IP version ٦ 
IPSEC IP Secure Protocol 
ISDN Integrated Services Digital Network 
ISP Internet Service Provider 
L٢TP Layer ٢ Tunneling Protocol 
LA Location Area 
LLC Logical Link Control 
MAP Mobile Application Part 
MDNS Mobile Domain Name System 
MS Mobile Station 
MSC Mobile Switching Center 
MT Mobile Terminal 
MTBF Mean Time between Failures 
MTTR Mean Time to Recovery 
N/A Not Applicable 
NAS Network Access Server 
NAT Network Address Translation 
NTP Network Time Protocol 
O&M Operations & Maintenance 
PAP Password Authentication Protocol 
PCF Packet Control Function 
PDP Packet Data Protocol 
PDN Packet Data Network 
PDSN Packet Data Service Node 
PLMN Public Land Mobile Network 
POS Point of Sales 
PTM-G Point-to-Multipoint Group Call 
PTM-M Point-to-Multipoint Multicast 
QoS Quality of Service 
RA Routing Area 
RADIUS Remote Authentication Dial In User Service 
RIP Routing Information Protocol 
RSC Register Service Center 
RTOS Real Time Operating System 
RTP Real-time Transport Protocol
GPRS/SMS FAM User manual 
٩ 
RTU Remote Terminal Unit 
SCADA Supervisory Control and Data Acquisition 
SGSN Serving GPRS Support Node 
SIM Subscriber Identify Module 
SMS Short Message Service 
SMSC Short Message Service Center 
SNMP Simple Network Management Protocol 
STK SIM Tool Kits 
TCP Transmission Control Protocol 
TDMA Time Division Multiple Access 
TMN Telecommunication Managed Network 
TTL Time to Live 
UDP User Datagram Protocol 
UIM User Identify Module 
UMTS Universal Mobile Telecommunication System 
USSD Unstructured Supplementary Service Data 
UTK UIM Tool Kits 
VLR Visitor Location Register 
WAN Wide Area Network 
WAP Wireless Application Protocol 
WDDN Wireless Digital Data Network
GPRS/SMS ACTM User manual 
١٠ 
Chapter 2 Product Introduction 
This chapter describes the overview of the ACTM system, function and 
specification, by reading this chapter, the reader can understand the ACTM 
system configuration, product accessories and detail function. 
١. Introduction 
٢. System function and feature 
٣. Specification 
٢.١ Introduction 
GPRS network theoretically can provide a maximum bandwidth ١٧١.٢Kbps, actually, it 
works at ٤٠~١٠٠Kbps bandwidth (it depends on service provider’s operation policy). As we 
know, GPRS is packet based network which provides TCP/IP communication channel. 
GPRS/SMS ACTM (Fixed Asset Monitoring) is an enhanced GPRS/SMS messenger (GPRS or 
CDMA service optional) which integrated with I/O port, RTU (Remote Terminal Unit), 
Relay, Sensor functions, it can help people to monitoring, control,SMS alarm the remote 
devices. 
GPRS/SMS ACTM main apllication filed is Home Security, Power grid automatization, 
industrial monitoring, traffic management, weather, finance, Basic Environmen protecting, 
colliery, Oil field etc, especially, apply in security, remote control. Implement transparent 
data transmission over GPRS/SMS network. 
The Typical system diagram is as below:
GPRS/SMS ACTM User manual 
٢.١.١ Size 
ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram, 
according the different applications, there are mounting holes on both sides to meet the 
needs of a variety of industrial applications. 
ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram, 
according the different applications, there are mounting holes on both sides to meet the 
needs of a variety of industrial applications. 
١١
GPRS/SMS ACTM User manual 
١٢ 
٢.١.٢ Accessories 
In order to protect products during shipment, ACTM-9220 GPRS/SMS ACTM has been 
packed properly. You may need to keep the packing materials for reshipping after you 
open the pack box. 
ACTM-9220 ACTM package includes: 
 ACTM-9220 ACTM ١ piece (Packed according to P/O) 
 +12V Power adapter ١ piece 
 2.5 meters antenna ١ piece 
 User manual ١ Piece(CD-ROM) 
 Qualified & Repair Card ١ piece 
Optional Accessories: 
 9Dbi High gain magnet antenna 
 Yagi antenna 
 Fixed antenna 
 Cascading Cable(SMA interface) 
 Configuration and firmware update cable 
After you open the box, you should count it carefully with your purchase order. 
٢.٢ System function and feature 
٢.٢.١ Main function 
 Industrial Design 
GPRS/SMS ACTM is industrial design which built-in watchdog chipset to ensure the system 
work continuously, Watchdog monitoring the GPRS module and CPU all the time, if the 
GPRS module or CPU does not response for long time, ACTM will restart automatically. 
ACTM is very suitable for long-term continuous work applications. 
 Support Wireless Sensor 
ACTM-٩٢٢٠ GPRS / SMS ACTM supports RF wireless sensors, connected through 
RF٤٣٣.٩٢Mhz frequency with wireless sensors, ٨-way wireless zones, support ٤٠ wireless 
sensors, and real-time monitoring of the state of the sensor, when the sensor battery is 
low or disconnect the connection, tamper switch, ACTM will send alarm information. 
 Transparent data transmission 
GPRS/SMS ACTM provides full transparent data transmission channel through RS٢٣٢ 
interface it use for connect different types of PLC, RTU which extend the scope of ACTM 
application, and better services for users. 
 Main and backup data center
GPRS/SMS ACTM User manual 
GPRS/SMS ACTM support main and backup data center, user can set both main data 
center ip address or domain name, when ACTM fail to connect with main data center, it will 
try to connect backup data center automatically. 
 Embedded Li-battery and Temperature sensor 
GPRS/SMS ACTM built-in ١٠٠٠mA Lithium battery, it can work for ٦ hours if the external 
power supply cut off. Also, ACTM will send alarm message to notify the user that the 
external power supply was cut off. the built-in temperature sensor can real-time 
monitoring of environment temperature, ACTM also support t external digital temperature 
sensor that monitor user’s device surface temperature, when the temperature lower or 
higher than the specified value, ACTM will send alarm message, when the temperature 
returned to normal, ACTM will send notice message to user also. 
 User-define alarm SMS 
GPRS/SMS ACTM support User-define alarm SMS, according to alarm port status, ACTM 
will choose the user pre-define content, and send to user mobile phone by SMS, it’s easy 
for user to understand alarm message. 
 I/O status Buffer 
ACTM has NVRAM buffer to save the I/O status data during GPRS/SMS tunnel problem, 
when the GPRS/SMS tunnel return to normal, ACTM will send buffer all data immediately, 
NVRAM has feature for save data even power lose, so even ACTM power lose, the buffer 
data will still save. 
 Ring and SMS alarm 
ACTM support ring and SMS for sending alarm message, when the alarm occurred, ACTM 
will start ring for ١٠ seconds, and then send alarm SMS to users. Users also can remote 
setting and control ACTM by SMS. 
 SMS receipt 
To ensure user receive the alarm messages, user can set the alarm SMS resend frequency, 
unless the alarm clear or receive ACK message receipt from user phone, ACTM will repeat 
to send alarm SMS by Specified frequency and interval. 
 Alarm clear message 
All of ACTM I/O port can be set the alarm clear message, when the port alarm status clear, 
ACTM will send alarm clear SMS to notice user. 
 Regularly report the I/O status 
ACTM-٩٢٢٠ ACTM support auto send I/O port status by specified time, after user set the 
time, ACTM will send the port status on specified time daily. 
١٣ 
 DO port programmable output 
ACTM DO (digital output) port supports programmable output, according to the 
requirement of user site, the level of output level, switching time, times would be 
programmable. 
 Zone type 
ACTM DI ports support zone type setting which can be set to as common zone, delay zone, 
intelligent zone, emergency zone, home zone, according to the user site conditions and 
sensor type, set the correct zone type to prevent false alarm, missing alarm. 
 GPRS SMS work at the same time
GPRS/SMS ACTM User manual 
ACTM communication through GPRS to data center, at the same time, ACTM also can occur 
SMS to the user's mobile phone, so that’s insuring the user receive the alarm message via 
GPRS and SMS. 
 Timing arm/disarm, password arm/disarm 
ACTM support timing arm/disarm function, it can perform a specified time every day to 
arm/disarm; ACTM also support any mobile phone number via a password to arm/disarm, 
after the instruction is executed successfully, ACTM will arm/disarm information to the 
administrator phone as well. 
 Camera capture picture 
ACTM provides the interface to connect with camera, real-time remote image capture, with 
the ACTM IO ports, real-time capture images when an alarm is generated, and sent to the 
data center; ACTM can be set to a fixed time interval for continuous capture images as 
well. 
 MODBUS Protocol programmable output 
ACTM provides storage and forwarding the command functions of the MODBUS protocol, 
users can pre-save the common command to ACTM, and ACTM will send the command 
PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically. 
١٤ 
 Clock synchronization 
ACTM support clock synchronization; it can read the clock from SMS or get clock from 
management platform by GPRS. 
 Cell phone and PC be Data service center 
GPRS/SMS ACTM supports cell phone and PC server to be data service center, if PC to be 
service center, please use Arian ACTM management platform software, it supports SQL 
data base, Google map etc. it can monitor thousands ACTM via GPRS; if the stations 
exceeds ٥٠٠ points, we suggest use ACTM management platform. 
 Graphical configuration software 
ACTM-٩٢٢٠ GPRS/SMS ACTM provide full graphical software configuration, easy to use, 
and supports import or export configuration file; so users just simply click a few icons to 
quickly setup ACTM system. 
 Worldwide applications 
GPRS/SMS ACTM has broad range of applications; it can be used in industrial remote 
monitor, security, meteorology, environmental protection, water conservancy, electric 
power industries. 
To more suitable of industrial M٢M applications, Arian can quickly modify the software and 
hardware according to customer requirements. 
٢.٢.٢ Part of compatible sensor 
The below item is part of ACTM compatible sensors: 
Float Water Level Sensor 
Temperature Sensor 
Pressure Sensor 
Magnetism Detector 
Speed Sensor 
Flow Sensor 
Infrared Detector 
Shock Sensor 
Wind Sensor 
Smoke Sensor 
Lighting Sensor 
Gas/LPG Detector
GPRS/SMS ACTM User manual 
١٥ 
Humidity Sensor 
Dynamo Sensor 
Water immersion Sensor 
Relay 
Microwave Motion Sensor 
Voltage Sensor 
Horizontal Sensor 
Emergency Button 
Sound & Flash Siren 
٢.٣ Specification 
Basic 
 GPRS Dual Bands ٩٠٠Mhz/ ١٨٠٠Mhz 
 GPRS Quad Bands ٨٥٠/٩٠٠/١٨٠٠/١٩٠٠Mhz (Optional) 
 CDMA ٨٠٠mhz (Optional) 
 Dual SIM Slot (Optional) 
 Self-define re-connecting interval 
 Clock synchronizing 
 Support external temperature sensor 
 Embedded Temperature Sensor 
 Support Temperature verify 
 I/O status buffer 
 Self-define report I/O status daily 
 Self-define online report interval 
 AI and the TE port upper and lower limits 
 DO port programmable output 
 DI port zone type setting 
 Timing, password arm/disarm 
 GPRS SMS work at the same time 
 MODBUS Protocol programmable output 
 Optical isolation terminal 
 Smart power management 
 Automatic power supply detection 
 Li-Battery inside (Optional) 
 Support ٢ DI pulse input (Optional) 
 Support GPS (Optional) 
 Support Max ١٦ Temperature sensors (Optional) 
 Support camera to Photograph 
 Support alarm link to photograph 
 PC based configuration tool 
 Real time OS, steady system 
 Watch dog design, ensure ACTM alive 
 Low consumption, industrial design 
 Fully type approved with ETSI GSM Phase ٢+ standard 
 Enhanced EMC/EMI design 
GPRS 
 Industrial class GPRS wireless module 
 Embedded PPP, TCP/IP Stack 
 Support main and backup service center 
 Support TCP/IP and UDP/IP 
 Transparent data transmission 
 Support RS٢٣٢ interface for data transmission
GPRS/SMS ACTM User manual 
١٦ 
 Supports DNS and dynamic data service center IP address 
 Support continually or sleep work mode 
 Support Carrier public & special APN 
 Work with ACTM management platform 
 Remote monitoring and control 
SMS 
 Support SMS and Ring Alarm 
 Set defense by SMS 
 Self-define SMS alarm message 
 Alarm/Disarm by SMS 
 Automatic send alarm SMS to mobile phone when alarm is triggered 
 Support ٤ service center number, and customized setting for center 
 SMS query ACTM signal strength 
 DO Relay triggered by alarm or SMS 
 Automatic SMS alarm when data above or below the preset levels 
 Support SMS remote configuration 
 Alarm clear message 
 Alarm SMS receipt and acknowledgement 
RF Wireless 
 Frequency: ٤٣٣.٩٢Mhz 
 Wireless transmission distance: ١٠٠meter standard environment 
 Support sensor low battery alarm 
 Support sensor Tamper alarm 
 Support sensor disconnect alarm 
 Real-time monitoring of sensor status 
 Anti-RF interference 
 ٨ wireless zones 
 Supports ٤٠ wireless sensor 
 Support ٥ remoter 
 Support wireless zone type setting 
Interface 
 Antenna: ٥٠Ω/SMA Female 
 SIM/R-UIM: ٣V 
 Configuration: RS٢٣٢ 
 Data: RS٢٣٢ (RS٤٨٥, Ethernet Optional) 
 DI: ٣ Ports (٠-٣V False, ٣-٣٦V True) 
 AI: ١ Port 
 DO: ١ Port 
 TE: ٢ ports 
Note: DI = Digital Input 
AI = Analog Input 
DO = Digital Output 
TE = Temperature 
Power 
 Voltage: ١٢V~١٨VDC (١٢~٣٠V Optional)
GPRS/SMS ACTM User manual 
١٧ 
 Default Voltage: DC١٢V 
 Consumption: 
Communication: ١٢٠mA@+١٢VDC 
Idle: ٣٠mA@+١٢VDC 
Others 
 Dimension: ٩٠mmx٦٢mmx٢٢.٥mm 
 Weight: ١٩٠g 
 Operation temperature: -٤٥~+٧٥ºC 
 Storage temperature: -٥٥~+٨٥ºC 
 Relative humidity: ٩٥% (no-condensing)
GPRS/SMS ACTM User manual 
١٨ 
Chapter 3 Installation 
This chapter describes in detail about ACTM system hardware installation, 
cable and sensor connections, by reading this chapter, the reader should be able to 
complete the ACTM hardware installation. 
١. ACTM installation and cable connection 
٢. Sensors installation 
٣. Grounding 
٤. Power supply 
٥. Check the mobile network 
٣.١ ACTM installation and cable connection 
GPRS/SMS ACTM should be installed and configured properly before putting it in service. 
The installation and configuration should be done or supervised by Arian qualified 
engineer. 
Attention: 
Do not install GPRS/SMS ACTM or connect/disconnect its cable when it is power on. 
3.1.١ Antenna and SIM card installation 
Using the antenna or other sharp items to click the top of the yellow dots SIM card 
connector, SIM card slot will automatically pop up, please put SIM card into the slot, and 
push the SIM card connector to the slot. The picture shown is as below: 
3.١.٢ RS232 configuration and Power cables installation 
ACTM-9220 ACTM signals and power supply is connected by industrial class pluggable 
terminals, ٣.81mm, ١٢Pin, and ١٤~٢٤AWG outlet cable is recommended. Each line 
definition refers to the following diagrams and tables. Also, you can find outlet cable 
definition table at top of ACTM-9220 ACTM cover. 
As shown in the following diagrams and tables, peel off the cable end about ٧mm and 
connect each terminal and cable (١٤~٢٤AWG cable recommended. Make sure that you 
have connected the terminals without any mistake.
GPRS/SMS ACTM User manual 
١٩ 
٧mm 
14~24AWG 
٧٧mm 
PIN Signal name Description MEMO 
Vin +5~18V Power Vin, recommend 
12V 
80mA@12V 
GND GND Power GND 
Vout Power Output This PIN voltage 
is same Vin 
DI1 Digital Input 1 Voltage range: 0-36V 
DI2 Digital Input 2 Voltage range: 0-36V 
DI3 Digital Input 3 Voltage range: 0-36V 
GND GND Signal GND; common with 
user’s device; RS232 GND 
AI1 Analog Input 1 Voltage range: 0-10V 
DO1 Digital output 1 Default is low level This PIN voltage 
is same Vin 
TX Send data RS232 TX 
RX Receive data RS232 RX 
UG Software Upgrade After connect with GND, 
ACTM will enter to 
software upgrade status 
Attention: 
The power cable should be connected correctly. We suggest double check before switch it 
on. Wrong connections may destroy the equipment. 
Power terminals: Pin ١ and Pin ٢; 
Here: Pin ١ is Power input “Vin” (+٥~+١٨VDC), Pin ٢ is”GND”. 
٣.٢ Sensors installation 
ACTM-9220 ACTM Provides 3 DI ports ,1 AI port,1 DO port. The sensors installation is as 
below:
GPRS/SMS ACTM User manual 
3.2.1 DI (Digital Input) sensor installation 
DI sensor only two states, high level (٣-٣٦V) and low level (٠-٣V). There are ٢ kinds of DI 
sensors, switching and voltage type. 
 Switch DI Sensor 
The switching DI sensor is like a simple switch, it only has ٢ statuses, ON or OFF. Connect 
the switch sensor ٢ signal lines to ACTM Vout pin and DI pins. it can be connected to 
multiple sensors; the common switching DI sensor such as Magnetic sensor, float level 
sensors, infrared sensors, pressure sensors, gas sensors, emergency buttons etc. the 
connections diagram as shown below: 
To achieve the alarm linkage, alarm equipment and DI port can be parallel interfaces to 
achieve the alarm linkage. When Magnetic sensors have closed, the sound and light alarm 
simultaneously closed, as follows picture: 
 Voltage DI Sensor 
The Voltage DI sensor provide DC voltage, connect the sensor Pin+ to ACTM DI pin, GND 
to ACTM GND, the common voltage DI sensor such as water immersion sensor, the 
connection diagram as shown below: 
٢٠
GPRS/SMS ACTM User manual 
3.2.2 AI (Analog Input) Sensor installation 
 Voltage AI Sensor 
Voltage sensor provide a voltage to the ACTM AI ports that required voltage between 
٠-١٠V, connect sensor Vout to the ACTM AI pin, GND connect to ACTM GND, the 
commonly used voltage AI sensor such as current sensor , Voltage sensor, fuel sensor etc. 
shown as follows: 
 resistance AI sensor 
Resistance AI sensor is like a variable resistor, such as resistance Humidity sensors, ١٠kΩ is 
the standard resistance; its resistance to humidity changes as the actual changing. 
Connect the sensor 2Pin to the ACTM AI and Vout pin. The commonly resistance AI sensor 
such as humidity sensor and so on. 
3.2.3 DO (Digital Output) device installation 
ACTM DO port provides the same voltage a Vin pin, and not more than ٢٠٠mA of current 
output. DO port can be used to control remote devices such as relays, photoelectric alarm, 
and alarm speakers. The installation diagram showed as below: 
٢١
GPRS/SMS ACTM User manual 
Attention: 
When the external power supply disconnect, ACTM will using internal battery power, the 
internal lithium battery supply voltage as ٣.٧V, so the DO port cannot provide ١٢V voltage, 
only output 3.7V voltage, so DO port will unfunctional. 
DO port provides maximum ٢٠٠mA output current, if use DO port to control equipment 
which more than ٢٠٠mA current, it should be added relay between ACTM and equipment. 
3.2.4 TE (Temperature) sensor installation 
ACTM provides two TE ports, TE٢ is the built-in NTC thermistor, the user can directly use it 
without installation; TE٢ is an external digital temperature interface, the digital 
temperature sensor connect to TE٢ port, it can be use for monitor equipment surface 
temperature, ambient temperature, water temperature, oil temperature and so on. The 
installation diagram showed as below: 
3.2.5 Wireless Sensor installation 
ACTM supports wireless sensors, wireless sensor using ٤٣٣MHZ RF to connect with ACTM 
controller, just assembled wireless sensor battery, and then through ACTM configuration 
tool to registered wireless sensor, the sensor would be connect to ACTM successfully. 
3.2.6 Camera installation 
ACTM supports camera capture picture function, camera connect to ACTM via RS232 port, 
DC 12V Power, the installation diagram showed as below: 
٢٢
GPRS/SMS ACTM User manual 
Please connect camera cable to ACTM according to the above figure cable color: 
Camera ACTM 
Green ----> RX 
Yellow ----> TX 
Black ----> GND 
Red ---- > Vout 
After finish the ACTM and camera cable connection, we need to complete the 
implementation of the following actions: 
 Turn OFF the debug information display on the configuration software 
 Turn ON the camera function on the configuration software 
 Disconnect the ACTM configuration cable to PC (ACTM mini-USB side) 
 Restart ACTM 
Notice: 
ACTM and the camera both is connected via the RS٢٣٢ interface, the camera can not be 
used when the ACTM at configuration status. ACTM configuration cable must be 
disconnecting, and then the camera should be work properly. 
3.2.7 RTU device installation 
ACTM provides RS٢٣٢ interface to connect other RTU device; it’s a three-line, installation 
diagram shown as below: 
٢٣
GPRS/SMS ACTM User manual 
٣.٣ Grounding 
To ensure a safe, stable and reliable ACTM-9220 GPRS/SMS ACTM operation, the ACTM 
cabinet should be grounded properly. Connect the ACTM cabinet to site ground wire at the 
ground point 
٣.٤ Power supply 
ACTM-9220 ACTM is designed with advanced power management technologies; it can 
operate standalone. The DC power is supplied via pluggable terminal Pin ١ (Vin) and Pin ٢ 
(GND). Detail definitions refer to above tables. 
Notice: 
About Power Supply: 
When ACTM-9220 GPRS/SMS ACTM communicates with base station, surge current will 
exceed normal current. Therefore, margins ٥ times over normal current may be required 
for external power supply. 
Normally, ACTM-9220 ACTM input power supply is +٥~+18VDC, in most cases, ١٢VDC/١A 
is recommended. Power supply ripple should be less ٣٠٠ mV. 
٣.٥ Check the mobile network 
Connect all signal and power cables, and double check it, connect antenna, insert a valid 
SIM and switch on power. ACTM-9220 “PWR” LED will light up. After around 30 seconds, If 
“NET” and “DATA” LED is flashing at same time (ON for 2 seconds then OFF for 2 seconds), 
it means the ACTM-9220 ACTM is working normally. If the “DATA” LED is flashing, it means 
there are data stream. If the “NET” LED lights up, it means that the ACTM-9220 ACTM has 
found and logged on mobile network. 
٢٤
GPRS/SMS ACTM User manual 
Warning: 
All cables should be connected correctly before switch on. 
Antenna should be connected before switch on, otherwise it may cause radio module 
problem 
٢٥
GPRS/SMS ACTM User manual 
٢٦ 
Chapter 4 Terminal Configuration 
This chapter describes in detail about ACTM configuration software, by 
reading this chapter, the reader should be able to know the function of ACTM, 
and change the configuration according actual requirement. 
١. Device Connection 
٢. Parameter Configuration 
٣. Parameter Detail 
٤.١ Device Connection 
ACTM graphical configuration software, it's easy to use and operation. Before the formal 
operation on the device, ACTM-٩٢٢٠ ACTM must be set to correct parameters. ACTM 
supports two ways to communication with PC. 
Notice: 
ACTM provide power switch (close the green socket), turn the power switch to the ON, 
ACTM will power ON and start run. 
 By using Arian configuration cable connect to ACTM Console port, which has upgraded 
firmware button (Blue Button) on the cable, when press in the button, ACTM will enter 
to firmware upgrade mode, and all of 4 LED will be ON; when press out the button, 
ACTM will enter to normal work mode, the Power LED will be ON, Data LED will be 
flash. the connection diagram shown as Below:
GPRS/SMS ACTM User manual 
 Connect PC's RS٢٣٢ interface to the ACTM terminals RX, TX, GND pin, if Connect 
ACTM terminal UG and GND pin together, ACTM will enter the software upgrade 
status. the connection diagram shown as Below: 
٢٧
GPRS/SMS ACTM User manual 
٤.٢ Parameter Configuration 
A. Connect ACTM 
According the above two ways to connected PC and ACTM, and installed ACTM 
configuration software on the PC. 
Switch ON ACTM power, start ACTM configuration software on the PC, click the interface in 
the navigation bar of the "OPEN “button, if the connection is successful, the software will 
automatically connect with the ACTM, and ACTM read all configuration information. If the 
connection is not successful, click on the navigation bar "PORT" button, select the correct 
port number, baud rate is ١١٥٢٠٠, and then click "OPEN" to retry the connection. 
When the information bar shows "Login Successful", it means that the configuration 
software and ACTM-٩٢٢٠ ACTM connection is successful, the picture shown as follows: 
٢٨
GPRS/SMS ACTM User manual 
Attention: 
After Configuration software connected ACTM successful, it will read ACTM configuration 
information and refresh automatically, this process may takes about ٢٠ seconds, and will 
slightly pause is normal. 
Using the configuration software, please turn OFF the ACTM debugging information, the 
debug information will affect the configuration software to read the ACTM information. 
When the SIM card is not inserted, or ACTM in the TCP / UDP mode, if the GPRS 
connection is not successful that ACTM will automatically restart, and then configure 
software will appear that failure to read/set parameters, just simply click "Connect" button 
on the navigation bar, ACTM will connect again. 
B. Query Parameter 
For query ACTM parameters, just click the optional checkbox in the left window (multiple 
choice), then click the navigation bar "Query" button, the configuration software will query 
the ACTM parameter information, and refresh the option box. 
Notice: 
if didn't tick any parameter options box, and click on "Query" button, ACTM will returns the 
current status values of all the IO ports in the information bar, this feature is easy to test 
sensor, and real-time query IO port status. 
C. Set Parameter 
To change the ACTM parameters, just click the optional checkbox in the left window 
(multiple choices), then modify the parameter value detail, and click the navigation bar 
"Save" button, the configuration software will save the parameter information to the 
٢٩
GPRS/SMS ACTM User manual 
ACTM, if save successful, it will show "the parameter have been save successful" in the 
message window ", the picture shown as below: 
Notice: 
If didn't tick any parameter options box, and click on "Save" button, ACTM will implement 
save command. After registrater the wireless sensor, you need by clicking on the "Save" 
button to execute the save. 
D. Series Port Configuration 
Click the navigation bar "Port" button to open the serial port configuration window, it need 
to select the appropriate connection port and the baud rate to connect to ACTM, the 
picture shown as below: 
Notice: 
The default login password is ٠٠٠٠٠٠, please do not change this password if it's not 
necessary; once change the parameter on the configuration page, you should also change 
the same login password here, otherwise ACTM will not able to login. 
٣٠
GPRS/SMS ACTM User manual 
E. Series Port Window 
The serial window is for testing and troubleshoots, click on the navigation bar "serial 
window" button, the window from the parameter window into the serial port window, for 
return parameter window, and just click "parameter window" button on the navigation bar. 
Attention: 
Send commands to the ACTM in the serial port window may bring unexpected problems; 
usually, please do not enter to the serial port window mode. 
F. Common Parameter 
Click the navigation bar "Common setting" button to open the common parameter settings 
window, you can select the frequency parameter to the common parameters window, and 
it’s for mass and quickly configuration ACTM. the picture shown as Below: 
G. All 
Click the navigation bar "All" button, it will select all option on the Parameter Configuration 
page, that’s easy for user to operation. 
H. Clock Synchronization 
Click the navigation bar "Clock Synchronization" button, ACTMcfg software will ready the 
computer clock information, and write to ACTM. 
Notice: 
ACTM supports three way to clock synchronization: configuration software, SMS, Data 
center via GPRS; by the configuration software and SMS clock synchronization, when 
ACTM power lose, the clock will automatically be zero, and need to clock synchronization 
again; by the GPRS mode, ACTM will clock synchronization by each login data center, we 
recommend using GPRS for clock synchronization. 
٣١
GPRS/SMS ACTM User manual 
I. Restart 
Click the navigation bar "restart "button, ACTM will immediately restart, and show "restart 
the device successful "in the information bar, about ١٠ seconds, click the "Connect" 
button , software will try to connect ACTM again. 
J. Default Parameter 
Click the navigation bar "Default “button, ACTM will revert all parameters to the default. 
Attention: 
This operation will restore ACTM parameters to factory state, it need to re-set ACTM 
parameters in order for ACTM to work again. 
K. Import/Export 
Import / export feature is mainly used for quickly and easy to mass ACTMs, click the menu 
bar "File “option under the "Export ", you can export the current configuration to be INI 
file. Click menu bar "File “option under the "Import ", then select the INI file which saved 
before, you can import the original configuration files in the current software 
Suggestion: 
"Import / Export" function can be used with the "Common Parameters” together, after the 
import parameters, click "Common Setting" and "All" button, then click “Save" button, this 
way will quickly save all of parameter you need. 
Attention: 
During "Import / Export “parameter, due to software will read/write large data, software 
may pause a few seconds, its normal. 
٤.٣ Parameter Detail 
A. SIM Para. 
Click the left mouse button on "SIM Para."; enter to the SIM card parameter setting, the 
picture shown as below: 
٣٢
GPRS/SMS ACTM User manual 
 APN Name (APN) 
Follow the prompts to enter information into the access point name (access point name 
cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" 
button on the navigation bar ", the message bar will show "parameters set successfully". 
Attention: 
Access Point Name (APN) is mobile operator to provide users with different access network 
types; you must query the APN name from the local operator, and then modify the APN 
name on the ACTM, so ACTM will able to connect to local GPRS network. 
 Username 
Login GPRS service username, usually empty 
 Password 
Login GPRS service password, usually empty 
B. RTU Connection Setting 
Click the left mouse button on "RTU Setting"; enter to the RTU connection setting, the 
picture shown as below: 
٣٣
GPRS/SMS ACTM User manual 
 Band 
Serial port configuration, selectable baud rate is ٣٠٠-١١٥٢٠٠. 
Attention: 
This band is same band with configuration software connect to ACTM, if you modify this 
band rate, simultaneously modify configuration band, then the configuration software able 
to connect the ACTM. 
 Data bit 
Serial port configuration, data bits is ٨-bit usually 
 Stop bit 
Serial port configuration, usually is ١ stop bit 
 Parity bit 
Serial port configuration, parity bit is NONE usually 
 Data packet interval 
١٠٠-٢٠٠٠ms, RTU Packet Minimum time interval, the default is 300ms 
 Customized RTU Command 
ACTM can end command to RTU automatically, command is hex code, no space between 
commands, for example: the command is ٥٥ ٤٥ ٠٠ ٠١ ٠٠ ٢٣, so just fill in as ٥٥٤٥٠٠٠١٠٠٢٣ 
 Data Header 
Add data head on sending RTU data to center; Format: ID(Max ١٦ byte ASCII 
code)@time,date(٦ byte, HEX format)@ data (hex code) 
 Command Interval 
Interval for sending RTU commands within group 
 Group commands Interval 
Interval for sending RTU commands between groups 
 SMS RTU 
At the SMS mode, ACTM can forward RTU data via SMS to the data center and 
pass-through SMS data from data center to the RTU seires port 
C. IP Channel Setting 
٣٤
GPRS/SMS ACTM User manual 
The Parameter is for ACTM work on TCP/UDP mode; click the left mouse on"IP Channel"; 
enter to the IP parameter setting, the picture shown as below: 
 Main IP address 
x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center 
through domain name. 
 Main Domain Name 
Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM 
will analysis domain name to be IP address, then using the IP address to connect data 
center. 
 Main Port 
١-٦٥٥٣٥, Main data center IP port 
 Backup IP address 
x.x.x.x, Backup data center IP address. if ACTM cannot connect to main IP address many 
times, ACTM will try to connect backup IP address. 
 Backup Domain Name 
Backup data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; 
ACTM will analysis domain name to be IP address, then using the IP address to connect 
data center. 
 Backup Port 
١-٦٥٥٣٥, Backup Data center IP port. 
 Heartbeat Interval 
٠-٦٥٥٣٥ Seconds, Heartbeat interval, if value is 0, ACTM will don’t send heartbeat data. 
The default interval is 40 seconds. 
The heartbeat is link maintain parameter, that is the heartbeat interval, ACTM periodically 
sends the fixed format of heartbeat packets to data center, which has maintained a link 
connection. This is because the network operators in order to prevent terminals linked to 
the Internet, but don't transferring data, taking the wireless network resources, as found 
in the terminal does not transmit data within a certain period of time, it will kick off the 
assembly line to the terminal. 
 Work mode 
٣٥
GPRS/SMS ACTM User manual 
GPRS transmission work mode, IO protocol mode will send&receive data through Arian 
protocol, and it use for connect ACTM management platform; transparent mode, using the 
transparent data channel, and sends heartbeat packets, it’s for connect to other platform 
or data center. 
 Sleep Mode 
For save GPRS data transmission, ACTM provide 2 kinds of online solution; always online, 
ACTM will online GPRS all the time; Sleep mode, ACTM will wait for specified time, if there 
is no alarm and no data transmission, GPRS will automatically be offline, however, it can be 
activated by SMS or ring 
 Offline interval 
٠-٦٥٥٣٥ Seconds, ACTM offline waiting time, the default is 300 seconds. 
 Reconnection Interval 
٠-٦٥٥٣٥Seconds, IP channel failure or reconnect after sleep time interval, if set to ٠, ACTM 
will don't try re-connect, only wake-up can make ACTM on-line, the default value is 300 
seconds. 
 A group of the number of re-connect 
一Set to ٠, no change to backup channel, only try to connect the main channel 
 A group of reconnection interval 
一A group of reconnection interval, Seconds 
 Two groups of reconnection interval 
Two groups of reconnection interval, Minute!!! The default is 10 minutes. 
 Login attempt times 
Set as ٠, ACTM only send a registration packet once, Data center is not neccessary to reply 
registration ACK package; ١ to ١٠, Data centers must respond to the registration ACK 
package, otherwisem, ACTM will disconnect and reconnect 
 Heartbeat ACK 
According to the GPRS signal unstab area, we can enable the heartbeat ACK function. If 
ACTM did not receive heartbeat ACK packets from data center as ٣ times, ACTM will 
disconnect the link and try to reconnect. 
 SMS Backup 
For the GPRS network often abnormal area, we can enable SMS backup function, when the 
GPRS link is disconnect, ACTM will also send a message via SMS to the data center; When 
GPRS recovery, ACTM will send this information to the data center again. 
D. SMS Channel Setting 
The parameter is for ACTM work on SMS mode, click the left mouse button on "SMS 
Channel "; enter to the SMS Channel parameter setting, the picture shown as below: 
٣٦
GPRS/SMS ACTM User manual 
 Service Number 
For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please add country code on the front, 
the number is for receive alarm SMS from ACTM, and remote control ACTM through SMS. 
 Service Number Mode 
The Service number supports 4 modes: 
Alarm mode, this number only receive alarm SMS, but it can not using SMS for remote 
settings ACTM. 
Alarm+Config mode, ACTM send alarm SMS to this number, the number can be remote 
control ACTM as well. 
Config mode, this number only for remote config ACTM, it cannot receive alarm SMS. 
Administrator mode: This number supports Alarm + SMS all functionality, and receive all 
arm and disarm information via SMS. 
 Daily report 
٠٠:٠٠-٢٣:٥٩, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable. 
 Report at specified intervals 
٠٠:٠٠-٢٣:٥٩, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable 
 Alarm Mode 
For real time inform user about alarm, ACTM support 3 kinds of alarm mode. SMS mode, 
ACTM only send alarm SMS; Ring mode, ACTM only Ring; SMS+Ring mode, ACTM will ring 
for ٦٠ seconds, then send alarm SMS. 
 SMS Alarm Content 
For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the 
alarm happen, ACTM will send the pre-set SMS to service number. customize mode, ACTM 
will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send alarm 
SMS according Arian protocol 
E. I/O Port Setting 
The parameter is for ACTM I/O port setting, click the left mouse button on "I/O port 
setting"; enter to the I/O parameter setting, the picture shown as below: 
٣٧
GPRS/SMS ACTM User manual 
Attention: 
Configuration software can set ACTM-9220 and ACTM-9220 product parameter, 
ACTM-9220 provide 3 DI, 1 AI, 1 DO, 2 TE ports, ACTM-9220 provide 7 DI, 4 AI, 4DO, 2 
TE Ports. When set the ACTM-9220 I/O ports, just disable port alarm for DI4, DI5, DI6, 
DI7, AI, 2, AI3 etc. if enable the not exist port alarm, there may be some illegal value, the 
false alarms may happen. 
 DI Alarm Status 
Low level, when port is low level, alarm happen; 
High level, when port is high level, alarm happen; 
Status change, when the port status change, alarm happen; 
Pluse input, if connect to pluse input device, choose this option; 
The default is Disable alarm. 
 DI Zone Type 
Normal Zone: Start detect after arm immediately. 
Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. 
Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for 
PIR montion sensor, in case the wrong alarm. 
Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for 
connect to emergency button, smoke sensor etc. 
Home Zone: This zone can be turning off by Home button of remote controller; when user 
at home, he can use this function for disable some sensor inside home. 
 DI Zone Type 
Normal Zone: Start detect after arm immediately. 
Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. 
Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for 
PIR montion sensor, in case the wrong alarm. 
 DI trigger duration 
٣٨
GPRS/SMS ACTM User manual 
Unit: ١٠٠ms, default value is ٢, so the duration is ٢٠٠ms. When DI port achieves alarm 
value, and keeps after specified duration, occur alarm. According to part of senors (such as 
float level sensors, pressure sensors), the value may be hovering between alarm/normal, it 
may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set 
DI port trigger duration, if DI port at alarm state and exceeds specified duration, then 
ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes. 
 DI Alarm Customize SMS 
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message 
content to the service number. For example: Warning, tower water level is low! 
 DI Alarm Clear Customize SMS 
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear 
message content to the service number. For example: Warning, tower water level return to 
normal! 
Attention: 
All customize SMS content can not include a comma, the comma as a parameter separator 
that can not be used as a custom SMS content, we have to use other symbols instead of 
comma. 
 WI Zone Type 
Close Zone: Close this wireless zone. 
Normal Zone: Start detect after arm immediately. 
Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. 
Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for 
PIR montion sensor, in case the wrong alarm. 
Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for 
connect to emergency button, smoke sensor etc. 
Home Zone: This zone can be turning off by Home button of remote controller; when user 
at home, he can use this function for disable some sensor inside home. 
 WI Alarm Customize SMS 
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message 
content to the service number. For example: Warning, detect people come in! 
Notice: 
Here is set wireless sensor WI zone types and customize SMS content, for using a wireless 
sensor, you must first register wireless sensors, according the wireless sensor registration, 
please refer to the "Wireless parameter setting". 
 Wireless sensor online detect period 
The Default value is OFF detect function; all of Arian wireless sensor/detector products 
support online detection function, the sensor sends online informatoin to ACTM about 
every ٣ hours, ACTM recieve online information that means sensor is online; if ACTM didn't 
received sensor online information for long time that means sensor already disconnect, 
ACTM will occur sensor disconnect alarm. The detection time can be set to ٨, ١٦, ٢٤ to ٩٦ 
hours, in order to avoid false alarms, we can choose the appropriate online detection 
period or OFF detection function. 
 AI Alarm Status 
This is AI port Upper&Lower voltage value, ٣٣٠ is ٣.٣V, For example: ١٠٠~٢١٠, when AI 
port voltage Lower than ١V, lower limit alarm happen; when higher than ٢.١V, Upper limit 
alarm. Value is 0~0 is disable AI port alarm. 
٣٩
GPRS/SMS ACTM User manual 
Notice: 
To prevent fluctuations in the value of AI interfaces to occur repeated alarm, when the AI 
interface value beyond the scope of the directive over the value of +10, ACTM will occur 
alarm, when the AI interface value back to the normal range -10, ACTM will occur alarm 
clear. This value can be set through”AI Port alarm Accuracy”. 
For example: set value as 100~210, so when the AI port value to be 90 or 220, ACTM will 
occur alarm, when the temperature return to 110 or 200, ACTM will occur alarm clear. 
 AI trigger duration 
Unit: ١٠٠ms, default value is 1, so the duration is 1٠٠ms. When AI port achieves alarm 
value, and keeps after specified duration, occur alarm. According to part of senors (such as 
voltage sensors, current sensors), the value may be hovering between alarm/normal, it 
may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set 
AI port trigger duration, if AI port at alarm state and exceeds specified duration, then 
ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes. 
 AI Alarm Customize SMS 
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message 
content to the service number. For example: Warning, water pressure exceeds the limit! 
 AI Alarm Clear Customize SMS 
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear 
message content to the service number. For example: Warning, water pressure return to 
normal! 
 AI Port alarm Accuracy 
The current value is greater than or lower than the set alarm value and more than the 
accuracy value, alarm hapeen. 
 TE Temperature Alarm Status 
This value is the temperature of the upper and lower limits, the units is ℃. For example: 
-5~28, when the temperature is lower than -5℃ or higher than 28℃, the alarm will occur; 
When the temperature returned to normal, the alarm clear will occur. 0~0 is disable TE 
port alarm. 
Notice: 
To prevent fluctuations in the value of TE temperature to occur repeated alarm, when the 
temperature value beyond the scope of the directive over the value of +1, ACTM will occur 
alarm, when the AI interface value back to the normal range -1, ACTM will occur alarm 
clear. 
For example: set value as -5~28, so when the temperature to be -6 or 29, ACTM will occur 
alarm, when the temperature return to -4 or 27, ACTM will occur alarm clear. 
 TE trigger duration 
Unit: ١s, default value is 1, so the duration is 1 second. When TE port temperature 
achieves alarm value, and keeps after specified duration, ACTM will occur alarm. According 
to temperature value may be hovering between alarm/normal, it may occur repeat 
alarm/alarm clear information, disturb user to determine. ACTM can set TE port trigger 
duration, if TE port at alarm state and exceeds specified duration, then ACTM will occur 
alarm. For example: the trigger duration set to ٣٠٠, so that's ٥ minutes. 
 TE Temperature Alarm Customize SMS 
The string length is not longer than 40, when the alarm occurs; send this alarm message 
content to the service number. For example: Warning temperature is too low! 
 TE Temperature Alarm Clear Customize SMS 
٤٠
GPRS/SMS ACTM User manual 
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear 
message content to the service number. For example: Warning clear, temperature return 
to normal! 
Attention: 
ACTM provides two kinds of temperature, TE1 is external digital temperature interface, it 
connects to extend temperature sensor, high accuracy. TE2 is embedded NTC temperature 
sensor, it’s for test environment and ACTM device temperature. 
 DO Output 
Control DO output, When DO output mode as High or Low level mode, choose high or low 
level the default is low level; the DO port output voltage is same as Vin PIN voltage.; When 
the DO output mode as programming mode, choose the high level to trigger the 
implementation of the programmatic output, after the implementation returns an 
unavailable level. 
 DO Output Mode 
ACTM DO port support 2 mode, High or Low Level Mode,output as High or Low Level 
simply; Program Modem,output as programming level 
 DO Output Program 
Example: 1,1,2,3,2,00:00:00; 1 is Port;1 is avaiable level,high or low; 2 is available level 
time period (Second); ٣ is unavailable level time period (Second); ٢ is cycle times; ٠٠:٠٠:٠٠ 
not implement as daily 
Notice: 
ACTM DO (digital output) port supports programmable output, according to the 
requirement of user site, the level of output level, switching time, times would be 
programmable. Please contact Arian technical engineer for instruction detail. 
 DO output link alarm 
When alarm trigger, link to DO output. 
 DO Output Link Program 
DO output the alarm link trigger port, type in the port name DI,TE,AI,WI (DI behalf of all 
DI port, DI١ specifically DI١ port only) 
 DO Smart Link 
For example: ٢,٦٠; ٢ times the specified port alarm within ٦٠ seconds, DO trigger output 
 Power Status Detect 
Detect external power status, if the external power disconnect, ACTM will send alarm SMS 
to service number. The default is ON. 
 Alarm Clear Message 
Set as ON, if detect port alarm clear, ACTM will send alarm clear message. 
F. Wireless Parameter Setting 
The parameter is for register wireless sensor, click the left mouse button on "Wireless"; 
enter to the Wireless parameter setting, the picture shown as below: 
٤١
GPRS/SMS ACTM User manual 
Notice: 
All wireless sensors must be registered on use wireless zones of the ACTM, and then it can 
be used. 
 Wireless Zone 
Zone: WI١ to WI٨ zones, each zone can be registered ٥ wireless sensors. 
Registrater: wireless sensor registerion, after choose the zone, click "Register", ACTM into 
the registration status, the information bar will prompt: Registratring ..., you need to take 
the wireless sensor to send an alarm signal (through Tamper button or alarm), when ACTM 
received this signal, you will heard "TA", it means sensor register successful. 
Cancel: click "Cancel" to cancel the current registration. 
Delete: select zone, then click "delete", it will delete the entire sensor on specified wireless 
zones. 
Delete All: click "Delete all", it will delete all wireless sensor from all zones. 
 Remoter 
Function: Arm, Disarm, Home button; total 3 remoter buttons, each button can be 
registerd for 5 remoter, it means each ACTM support max 5 remoter. 
Registrater: after choose the function button; click "Register", ACTM into the registration 
status, the information bar will prompt: Registratring ..., you need to push the button the 
remoter, and you will hear "TA" from ACTM, it means register successful. 
Cancel: click "Cancel" to cancel the current registration. 
Delete: select function button, then click "delete", it will delete the entire funmciton button 
of all remoter. 
Delete All: click "Delete all", it will delete all remoter on the all function buttons. 
Notice: 
Wireless sensor support tamper switch, low battery, link disconnect alarm, when ACTM 
disconnect link with sensors more than ١٦ hours, the disconnect sensor alarm will happen. 
٤٢
GPRS/SMS ACTM User manual 
After click the "Register" button, ACTM must receive the sensor signal within ٣ minutes; 
otherwise, ACTM will exit from register status. 
G. LED Screen Parameter Setting 
At the SMS Mode, ACTM can connect an LED Screen, the parameter is for LED Screen 
setting, , click the left mouse button on "LED Para."; enter to the LED parameter setting, 
the picture shown as below: 
 LED Screen 
At SMS mode, whether turn ON the LED screen function, when an alarm is occured, ACTM 
will send the alarm customize SMS content to the LED screen. if ACTM didn't connect with 
LED screen, turn OFFthis function. 
Attention: 
At GPRS communication mode, this option should be turned off. Data center platform will 
control the LED display via GPRS directly, it don't need ACTM to control. 
٤٣ 
 Window Number 
Send alarm information to the specified window number of LED screen 
 Display Time 
Alarm information display time period, ٠ to ٦٥٥٣٥ seconds, value ٠ is always show 
 Effects coding 
Alarm information display effects coding 
 Alignment 
Alarm information display Alignment 
 Display Speed 
Alarm information display speed, from ٠ to ١٠٠, the smaller the value are more faster 
 Stay time 
Alarm information display stay time 
 Font color
GPRS/SMS ACTM User manual 
Alarm information display font color 
 Font Size 
Alarm information display font size 
H. Run Setting 
The parameter is for ACTM run setting, click the left mouse button on "Run Setting"; enter 
to the Run parameter setting, the picture shown as below: 
 ACTM ID 
Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be 
location name, owner name, cell phone number etc. we recommend to be SIM card 
number, and record the ID. The valuable range is 1~32 bytes. 
 Display Debug Info 
Debug information is use for engineer solve the problem, usually, it should be OFF. 
Attention: 
If turn on the debug information, the configuring software may predictable behavior during 
read/write ACTM parameters, then we should turn off debug information, and re-connect 
ACTM. 
 Enable Camera 
ACTM supports remote image capture function, connected through the RS٢٣٢ interface 
with the camera, when ACTM connects with camera; you need to turn this option ON. 
 ACTM Communication Mode 
ACTM support 5 mode to communication with center: 
TCP mode, ACTM communication with data center via GPRS, and establish TCP connection 
with data center. 
UDP mode, ACTM communication with data center via GPRS, and establish UDP connection 
with data center. 
SMS mode, ACTM sends the alarm information via SMS to the service center number. 
٤٤
GPRS/SMS ACTM User manual 
TCP + SMS mode, ACTM communicate with data center via GPRS , and establish TCP 
connection with data centers; but also support SMS functions, when alarm generated, 
ACTM will send alarm information through GPRS and SMS at same time. At the applicaiton, 
GPRS for data center, SMS end user to receive alarm at real time. 
UDP + SMS, ACTM communicate with data center via GPRS , and establish UDP connection 
with data centers; but also support SMS functions, when alarm generated, ACTM will send 
alarm information through GPRS and SMS at same time. At the applicaiton, GPRS for data 
center, SMS end user to receive alarm at real time. 
 Config Password 
Using ACTM Configuration software to set up ACTM, it need password. Please enter new 
password. The default value is 000000。 
Attention: 
Please do not change the configuration password, if the password is incorrect, you will not 
able to set ACTM through configuration software. 
If you forget password, you can enter to the serial window, enter the command "at + 
ACTMdefault" to restore the default parameter, the password will restore the initial value 
of ٠٠٠٠٠٠. 
 Buzzer 
ON/OFF ACTM embedded buzzer 
 Defence Status 
Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM 
only monitor I/O status, but do not send alarm SMS. The default is not defence. 
Notice: 
From turn ON Defence, ACTM will enter defence status after ١٠ seconds. 
ACTM supports alias name to SMS to ARM/DISARM, the user just simply type in arm or 
disarm by the service center number. The command "at+defence=١" alias name is "arm"; 
the command "at+defense=٠" alias name is "disarm". 
 Timing Arm 
Executive ARM at the specified time daily. 
 Timing Arm 
Executive disarm at the specified time daily. 
 Password Disarm or Arm 
Any mobile phone can send SMS+password to remote disarm/arm, it can be set to 
maximum of ١٠ password, separated by commas. The default password is *, it means 
none. 
For example: send SMS”at+defence=1,123456” the 123456 is password, 1 means arm, 0 
means disarm. 
Notice: 
This function is use for remote arm/disarm, if there is people who wanna enter to the area, 
he can send password to arm/disarm. After SMS command send successful, ACTM will 
return an sucssful SMS, and send copy to the administrator phone. 
 RFID/Alarm Resend Times 
For data center to receive all the alarm, ACTM can set resend alarm times, value is 
0-65535. GPRS mode: ACTM resend alarm packet times if didn't receive center alarm ACK 
packet; SMS mode: ACTM resend alarm SMS times if didn't receive cellphone alarm ACK 
SMS. 
٤٥
GPRS/SMS ACTM User manual 
Notice: 
Set value as non ٠, the functional will effect. At the SMS mode, service number received 
alarm SMS should reply ACK SMS to the ACTM, otherwise ACTM will resend alarm SMS. 
There is a serial number for each alarm SMS, service number should reply ACK SMS as 
format: ACK - serial number, for example: ACK -١٢, service number reply ACTM that 
receives the serial number ١٢ alarm SMS. 
 RFID/Alarm Resend Interval 
٠-٦٥٥٣٥ Seconds, ACTM resend alarm data packet interval if do not receive alarm ACK 
(Include GPRS and SMS) 
 Continue Alarm Interval 
٠-٦٥٥٣٥ Seconds, When more than one alarm occurs, the time interval between continue 
alarm 
I. System Parameter 
ACTM system information, the option is only for query, it cannot be modify; click the left 
mouse button on "System"; enter to the system information, the picture shown as below: 
٤٦ 
 Manufacturer Name 
The default is Arian Ertebat Caspian Co. The Parameter is only for view. 
 Product Model 
The default value is ET٨٠٠٠ GPRS/SMS ACTM,The Parameter is only for view. 
 Software Version 
ACTM software version, The Parameter is only for view. 
 Hardware Version 
ACTM hardware version, The Parameter is only for view. 
 Config Tool Version 
Config Tool Version, The Parameter is only for view. 
 Product SN 
ACTM product SN, the Parameter is only for view. 
 Product Number
GPRS/SMS ACTM User manual 
٤٧ 
ACTM product number, The Parameter is only for view. 
 IMEI Number 
ACTM IMEI Number, The Parameter is only for view.
GPRS/SMS ACTM User manual 
٤٨ 
Chapter 5 Typical Application 
This chapter describes in detail about ACTM typical application, by reading 
this chapter, the reader should be able to know choose suitable mode and set up 
ACTM. 
١. SMS alarm application 
٢. ACTM management platform application 
٣. Transparent data transmission application 
٥.١ SMS alarm application 
For a small number of sites, SMS time delay is acceptable, simple operation, easy 
maintenance project, we recommended using SMS mode, the user can remote monitoring 
system through mobile phone, when an alarm occurred, ACTM will send SMS to mobile 
phone, according to alarm, the user can send commands directly control ACTM. The 
detailed SMS command instructions please check the attachment. 
Set ACTM to SMS mode that needs to configure the following parameters: 
 Service Number 
For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please pay attention to add country code 
on the front, the number is for receive alarm SMS from ACTM, and remote control ACTM 
through SMS. 
You can set up max four service center number. and must be set to at least one central 
number to take SMS mode effect. 
 SMS Alarm Content 
For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the 
alarm happen, ACTM will send the pre-set SMS to service number. Customize SMS mode, 
ACTM will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send 
alarm SMS according Arian protocol 
Pre-set customize SMS is more easy to read alarm information, we recommend using a 
customize SMS. 
 DI Alarm Status 
Low level, when port is low level, alarm happen; High level, when port is high level, alarm 
happen ;Status Change, when the port status change, alarm happen. The default is 
Disable alarm.
GPRS/SMS ACTM User manual 
According to the actual situation, set the I/O port alarm status, we only make example on 
DI port, please set AI and TE port alarm status at same. 
 DI Alarm Customize SMS 
The string length is not longer than ٤٠, when the alarm occurs; send this alarm message 
content to the service number. For example: Warning, tower water level is low! 
 DI Alarm Clear Customize SMS 
The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear 
message content to the service number. For example: Warning, tower water level return to 
normal! 
 ACTM ID 
Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be 
location name, owner name, cell phone number etc. we recommend to be SIM card 
number, and record the ID. The valuable range is 1~32 bytes. 
 ACTM Communication Mode 
ACTM communication with center mode; SMS mode, ACTM using SMS to communication 
with service number; TCP and UDP mode, ACTM using GPRS to communication with data 
service center. 
It must be set as SMS mode. 
 Defence Status 
Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM 
only monitor I/O status, but do not send alarm SMS. The default is not defence. 
It must be set as Defence status, so ACTM can monitor I/O port, and send alarm SMS. 
Attention: 
ACTM has a clock function, and using SMS to synchronization time, power up on ACTM for 
the first time, please send "Timecal" SMS to ACTM through mobile phone, then ACTM will 
reply "ACTM OK". Just set up once, ACTM will always using the clock running. For the 
command detail, please check Chapter ٧. 
Notice: 
After setting these parameters, we need to restart ACTM to take function effect. 
According the sensor installation, please check Chapter ٣ Installation. 
٥.٢ ACTM management platform application 
For more sites, complicated network, real-time is necessary, alarm history project, we 
recommend using ACTM management platform. ACTM management platform through the 
SQL database to save all alarm history, it's easy to use, and able to export excel report; 
through GOOGLE map to showing the location of all site, when an alarm occurs, the alarm 
immediately show red alarm logo on the map; with B/S structure, the user can 
management all device at anywhere where just open browser; multi-level permissions can 
be set to view and manage permissions, for normal users can only able to view, cannot 
operation. Below picture shown ACTM management platform software, more information 
please check Arian website. 
٤٩
GPRS/SMS ACTM User manual 
Set ACTM to connect ACTM management platform mode that needs to configure the 
following parameters: 
 APN Name (APN) 
Follow the prompts to enter information into the access point name (access point name 
cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" 
button on the navigation bar ", the message bar will show "parameters set successfully". 
According to different operator, enter to the correct APN name. 
 Main IP address 
x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center 
through domain name. 
 Main Domain Name 
Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM 
will analysis domain name to be IP address, then using the IP address to connect data 
center. 
Notice: 
The main IP address and main domain name must be input, if else, ACTM will not able to 
communication with ACTM platform. 
 Main Port 
١-٦٥٥٣٥, Main data center IP port 
 Work mode 
GPRS transmission work mode, IO protocol mode will send&receive data through Arian 
protocol, and it use for connect ACTM management platform; transparent mode, using the 
٥٠
GPRS/SMS ACTM User manual 
transparent data channel, and sends heartbeat packets, it’s for connect to other platform 
or data center. 
It must be set as IO protocol mode, so ACTM will use Arian communication protocol to 
connect with ACTM platform. 
 DI Alarm Status 
Low level, when port is low level, alarm happen; High level, when port is high level, alarm 
happen ;Status Change, when the port status change, alarm happen. The default is 
Disable alarm. 
According to the actual situation, set the I/O port alarm status, we only make example on 
DI port, please set AI and TE port alarm status at same. 
 ACTM Communication Mode 
ACTM communication with center mode; SMS mode, ACTM using SMS to communication 
with service number; TCP and UDP mode, ACTM using GPRS to communication with data 
service center. 
It must be set as TCP or UDP mode. 
 Defence Status 
Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM 
only monitor I/O status, but do not send alarm SMS. The default is not defence. 
It must be set as Defence status, so ACTM can monitor I/O port, and send alarm 
information. 
Notice: 
After setting these parameters, we need to restart ACTM to take function effect. 
According the sensor installation, please check Chapter ٣ Installation. 
٥.٣ Transparent data transmission application 
As RTU and PLC which provide RS٢٣٢ interface, ACTM provides RS٢٣٢ interface to connect 
with RTU and PLC, using transparent data channel that send RTU data to data center. Data 
center can use the RTU software or data center platform to receive ACTM+RTU data. 
Set ACTM to transparent data transmission mode that needs to configure the following 
 APN Name (APN) 
Follow the prompts to enter information into the access point name (access point name 
cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" 
button on the navigation bar ", the message bar will show "parameters set successfully". 
According to different operator, enter to the correct APN name. 
 Band 
Serial port configuration, selectable baud rate is ٣٠٠-١١٥٢٠٠. 
Attention: 
٥١
GPRS/SMS ACTM User manual 
This band is same band with configuration software connect to ACTM, if you modify this 
band rate, simultaneously modify configuration band, then the configuration software able 
to connect the ACTM. 
 Main IP address 
x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center 
through domain name. 
 Main Domain Name 
Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM 
will analysis domain name to be IP address, then using the IP address to connect data 
center. 
Notice: 
The main IP address and main domain name must be input, if else, ACTM will not able to 
communication with ACTM platform. 
 Main Port 
١-٦٥٥٣٥, Main data center IP port 
 Work mode 
GPRS transmission work mode, IO protocol mode will send&receive data through Arian 
protocol, and it use for connect ACTM management platform; transparent mode, using the 
transparent data channel, and sends heartbeat packets, it’s for connect to other platform 
or data center. 
It should be set as transparent mode usually, ACTM will use transparent channel to 
connect with data center. If the data center use Arian ACTM management platform while 
using the RTU, then select IO protocol mode. 
 ACTM Communication Mode 
ACTM communication with center mode; SMS mode, ACTM using SMS to communication 
with service number; TCP and UDP mode, ACTM using GPRS to communication with data 
service center. 
It must be set as TCP or UDP mode. 
Notice: 
After setting these parameters, we need to restart ACTM to take function effect. 
According the sensor installation, please check Chapter ٣ Installation. 
ACTM provides storage and forwarding the command functions of the MODBUS protocol, 
users can pre-save the common command to ACTM, and ACTM will send the command 
PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically. Please contanct 
Arian technical engineer for instruction detail. 
٥٢
GPRS/SMS ACTM User manual 
٥٣ 
Chapter 6 Operation 
This chapter describes in detail about ACTM operation and troubles shooting, 
by reading this chapter, the reader should be able to solve general ACTM 
problem. 
١. Panel Indications 
٢. ACTM operation Guidance 
٣. Trouble Shooting 
٦.١ Panel Indications 
There are four LEDs at ACTM-9220 ACTM front panel; it indicates the ACTM network, 
operation and alarm status. 
The below form is the LED indicators description: 
Status Sub-Status PWR NET DATA ALM 
Initial 
state 
Initialing Lights Up Lights Down Lights Up 
Check SIM Lights Up 1 Second Flash Lights Down 
GPRS Dial up Lights Up Lights Down 0.3 Second 
Flash 
GPRS registing Lights Up 0.3 Second 
Flash 
Lights Down 
Connecting to 
Data center 
Lights Up 0.3 Second 
Flash 
0.3 Second 
Flash 
Work 
state 
GPRS Standby 
(Sleep) 
Lights Up Lights Down 5 Second 
Flash 
GPRS/SMS work 
status 
Lights Up According the 
Signal strength 
to flash 
Flash on 
data 
transmission 
Light Up at 
battery power, 
flash at alarm 
happen 
Notice: 
After ACTM work well, the NET indicator will blink according to the signal strength, ACTM 
will query signal strength per minute. 
CSQ Signal strength in the ٠١-١٢, very fast flash; 
CSQ signal strength in the ٠٣-١٨, fast blinking; 
CSQ signal strength in the ١٩-٣١, slow blinking; 
After ACTM work well, PWR indicator will light up, DATA and NET indicator will light up for 
2 seconds and light down for 2 seconds. 
ALM indicator and buzzer that there is alarm occur, it will buzz or blink. When ACTM switch 
to battery power, the ALM LED will light UP.
GPRS/SMS ACTM User manual 
٥٤ 
٦.٢ ACTM operation Guidance 
ACTM is an intelligent wireless data terminal; after installation and setting, just connect 
sensor and power, then it will work well. 
ACTM should be installed at place with good radio signal receiving. For the cabinet and 
basement environment, we recommend to extend the antenna. 
Warning: 
For outdoor use, lightning should be considered. We propose to install an arrester between 
antenna and the ANT interface. Contact Arian technical support department for details. 
No routine maintenance is required for ACTM operation. At embedded application 
environment, the data service center will check ACTM operation information. 
٦.٣ Trouble Shooting 
Problem ١: All LEDs do not light up. 
Check all cables that are connected to the ACTM. 
Check the power supply adapter output voltage. 
If the power is correctly connected and there is no LED that light up, the ACTM may be 
failed. Contact to Arian or reseller for repairing. 
Problem 2: Instability after working long time. 
Please check whether the device is overheating, if overheated, put device into place in 
order to facilitate ventilation and cooling equipment. 
Problem 3: Using the configuration software to connect ACTM, but always unsuccessful. 
It needs to select the correct serial port and rate to connect ACTM, the default rate is 
١١٥٢٠٠. 
Attention: 
if use of USB-RS٢٣٢ converter cable to connect ACTM, please use Arian configuration 
cable. If use other brand of USB converter cable, please pay attention to buy high-quality 
cable, there is many bad-quality cable on the market, it may occur many problem to 
connect. In addition, PC's serial port is very easy to down, sometimes, you need to restart 
PC, and then try to connect. 
Problem 4: I have already connected the sensor, set the port alarm status, but when an 
alarm is occurred, ACTM did not send the alarm information. 
Please check to set ACTM defence to be "defence" status, after set to "defence" status that 
wait for ١٠ seconds, ACTM will start monitor I/O port status. 
Problem 5: I'm using the configuration software, and already connect to ACTM successful, 
but when I query/save parameter, it show query/save failed, so I cannot config parameter. 
ACTM in without cards or GPRS connection mode, it may automatically restart after 
connect ACTM unsuccessful, when you open the configuration software for while, it show 
errors, so ACTM may be restarted, then just click "connect" button, configuration software
GPRS/SMS ACTM User manual 
will try to connect ACTM again. Now, try to query/save parameter that will be successful. 
We suggest insert SIM first then set up ACTM. 
Problem 6: 
I'm using the configuration software, but there is many parameters are illegal value. 
The reason that's open the debugging information, ACTM debug information is large 
amount of data; it may affect configuration software to read/write parameter from ACTM 
sometimes. so please turn OFF the ACTM debug information then using the configuration 
software. 
Problem 7: ACTM shows ٤ lights flashing simultaneously, buzzer alarms fast flash, data 
cannot communication. 
This problem is ACTM internal battery will be no power soon. Please check the external 
power supply, and the power cord, you can check it on the ١٢PIN terminal. 
Problem 8: I connected ١٢V relay to ACTM DO port, set DO port output as high lever 
through configuration software, but the relay didn't action. 
DO port supply voltage is same Vin pin voltage, if using ١٢V relay, make sure the Vin pin 
voltage is the same as ١٢V. also, check the external power supply, if external power lose, 
ACTM will use internal battery, then DO only has ٣.٧V voltage, so relay will no action also. 
Problem 9: After turn ON ACTM power, it display PWR, DATA, NET, ALM all are lights up, 
and ACTM does not work. 
٤ lights up means the ACTM is in the software upgrade status check the upgrade firmware 
button on the configuration cable, just press the button, and restart the ACTM, ACTM will 
return to normal mode. 
Problem 10: ACTM buzzer sometimes occur a short "TA"sound. 
This is normal, when ACTM is no signal or cannot connect to data center for many times, it 
will automatically restart, the buzzer will occur short "TA" sound. 
Problem 11: Set up ACTM service center number, but the number does not receive alarm 
SMS. 
Check the service center number is that fill in correct format, the numbers must add the 
country code + or ٠٠ in the front, if doesn't fill in the country code or the + and ٠٠ doesn’t 
in the front, ACTM may not able to send out SMS. 
٥٥
GPRS/SMS ACTM User manual 
٥٦ 
Chapter 7 Attachment SMS 
Command 
This chapter describes in detail about SMS command detail, by reading this 
chapter, the reader should be able to how to remote control ACTM by SMS. 
١. Introduction 
٢. Command format 
٣. Command list 
٤. Command detail 
٥. Alarm information format 
٧.١ Introduction 
ACTM SMS command list defines a format of SMS communication format, its use for ACTM 
and the cell phone communication each other. Users should follow this document to the 
remote control ACTM by SMS. 
This command list applies to all ACTM products. 
٧.٢ Command format 
A. ACTM commands were signed by the command code, Parameter separator, parameters, 
three major elements; multiple parameters can be composed of the parameter list. 
Command total length should not exceed ٥٠ characters, if the command is too long, it can 
be sent by multiple divided SMS. 
Command Parameter separator Parameter, Parameter list 
Command “=” ( Separator between command and 
parameters) 
“,”(Separator between Multiple parameters) 
“?”(Enquiry symbol) 
Parameter 
Command=param1,param2,param3…….. 
Command? 
Attention: 
We must be set ACTM service number to be remote cell phone number, other phone 
numbers send commands to the ACTM, ACTM will do not implement.
GPRS/SMS ACTM User manual 
٥٧ 
٧.٣ Command list 
Timecal 
ACK 
At+ACTMpsw 
At+ACTMrst 
At+transtype 
At+ACTMid 
At+almlvset 
At+almlvread 
At+almbat 
At+defence 
At+outctrl 
At+inctrl 
At+almclr 
At+almpoint 
At+almsect 
At+servnum 
At+servalm 
At+almparam 
At+almflag 
At+mservip 
At+bservip 
At+mservname 
At+bservname 
At+sleepmode 
At+conntry 
At+miscintv 
At+accinfo 
٧.٤ Command detail 
Command Timecal 
Function SMS Clock synchronization command 
Parameter None 
MEMO This command only through SMS, it cannot implement by console port. 
Example: 
Timecal 
Returns: 
ACTM TIME CALIBRATION OK,2011/01/18-09:54:47 
Command At+ACTMrst 
Function ACTM reboot 
Parameter None 
MEMO There is no response SMS from ACTM, after send command, ACTM will 
restart immediately. 
Example: 
At+ACTMrst 
Returns: 
Command At+transtype 
Function ACTM with data center communication way 
Parameter ? Query the command current value, example: At+transtype? 
0 Using SMS for communication with service center cell phone 
1 Using TCP for communication with data center 
2 Using UDP for communication with data center 
3 Using TCP+SMS for communication with data center 
2 Using UDP+SMS for communication with data center 
MEMO The default is 0,SMS mode 
Example: 
At+transtype=1 
Returns: 
transtype = ١ 
ACTM OK 
Command At+ACTMid
GPRS/SMS ACTM User manual 
Function ACTM ID (it cannot exceed 32 letters), this ID is ACTM identify number, 
٥٨ 
the service center to identify different SMS by this ID. 
Parameter ? Query current command value, example: At+ACTMid? 
ID Change ACTM ID to current value 
MEMO 
Example: 
At+ACTMid=SHENZHEN 
At+ACTMid? 
Returns: 
ACTM ID:SHENZHEN 
ACTM OK 
Command At+almlvset 
Function Set I/O port alarm level 
Parameter Para1, para2, para3 
Para1 port name, it is DI,AI,TE 
Para2 port number, it is 1,2,3,4,5,6,7 
Para3 port value: 
DI port: value 0, disable alarm 
value 1, low level alarm 
value 2, high level alarm 
value 3, the level status change alarm 
AI port: Min*Max, when AI port current value exceed range above +10, 
ACTM will occurred alarm, when AI port return to normal range -10, 
ACTM will occurred alarm clear. 
TE port: Min*Max, when TE port current value exceed range above +1, 
ACTM will occurred alarm, when TE port return to normal range -1, 
ACTM will occurred alarm clear. 
MEMO 
Example: 
Set DI3 port high level alarm command is as below: 
At+almlvset=DI,3,2 
Set AI1 port minimum value to 0, Maximum value to 100: 
At+almlvset=AI,1,0*100 
Set TE1 port minimum value to -20, Maximum value to 70: 
At+almlvset=TE,1,-20*70 
Returns: 
DI:٠x٠٠٠٠٠٠٢٠ 
ACTM OK 
Command At+almlvread 
Function Query IO port alarm value 
Parameter Para1, para2 
Para1 port name, it is DI, AI, TE, if there is no para2, the command will 
query all of port name value. 
Para2 port number, it is 1,2,3,4,5,6,7 
MEMO 
Example: 
Query DI3 port alarm value: 
At+almlvread=DI,3 
Query all of AI port alarm value: 
At+almlvread=AI 
Query TE1 port alarm value: 
At+almlvread=TE,1
GPRS/SMS ACTM User manual 
٥٩ 
Returns: 
DI(٠٣)LV=٢ 
ACTM OK 
Command At+inctrl 
Function Query current IO port status 
Parameter Para1, para2 
Para1 port name, it is DI, AI, TE, ALL; ALL will query all of Port value. 
Para2 port number, it is 1,2,3,4,5,6,7 
MEMO 
Example: 
Query DI3 port current value: 
At+inctrl=DI,3 
Query TE1 port current value: 
At+inctrl=TE,1 
Query ALL port current value: 
At+inctrl=all 
Returns: 
٠,0,0,0,0,0,0,0 
0,364,340,424 
0,36 
ACTM OK 
MEMO:the first line of returns is DI port current value, the second line of returns is AI 
port current value, the thired line of returns is TE port current value. 
Command At+outctrl 
Function Control DO port output high level or low level; High level: DC12V Low 
level: 0V 
Parameter ? Query DO port current output status, example: At+outctrl? 
Para1, para2 
Para1 DO port number, it is 1,2,3,4 
Para2 port value, 0 is low level, 1 is high level. 
MEMO Note: DO ports with memory function, if there is power-off, restart, 
ACTM can automatically restore the previous settings of the state. But 
there is always low level during ACTM boot. 
Notice: If set At+almlink, the At+outctrl command will be unfunction, 
the DO port will only control by port alarm. 
Example: 
Set DO1 port output high level 
At+outctrl=1,1 
Query DO port current output status 
At+outctrl? 
Returns: 
DO:١,١,١,١ 
ACTM OK 
Command At+almbat 
Function Detect external power status 
Parameter ? Query command current value, example: At+almbat? 
0 ACTM do not detect external power status, not occurred alarm. 
1 ACTM detects external power status, if there is change, ACTM will 
occur alarm. 
MEMO The default value is 1. 
Example:
GPRS/SMS ACTM User manual 
٦٠ 
Set detect external power status: 
At+almbat=1 
Returns: 
power status check enable 
ACTM OK 
Command At+defence 
Function Defence or not defence 
Parameter ? Query current command value, example: At+defence? 
٠ not defence, all IO ports are not in the surveillance state, that does 
not occurred alarm information 
١ defence all IO port are in the surveillance state. 
MEMO The default value is 1. 
Alias name "at+defence=١" alias name is "arm"; 
"at+defense=٠" alias name is "disarm". 
Example: 
Set ACTM defence 
At+defence=1 
Returns: 
DEFENCE 
ACTM OK 
Command At+almclr 
Function Alarm clear message 
Parameter ? Query command current value, example: At+almclr? 
٠ do not send alarm clear message 
١ send alarm clear message 
MEMO The default value is 1 
Example: 
Set ACTM send alarm clear message 
At+almclr=1 
Returns: 
ON 
ACTM OK 
Command At+almpoint 
Function Set ACTM report IO port status as appoint time everyday 
Parameter ? Query command current value, example: At+almpoint? 
Para1,Para2 
Para1 0 disable function, 1 enable function 
Para2 time format: hh:mm:ss 
MEMO 
Example: 
Set everyday 12:30:15 report current IO port status 
At+almpoint=1,١2:30:15 
Returns: 
auto send time point enable 
ACTM OK 
Command At+almsect 
Function Set ACTM auto report IO port status as specify interval 
Parameter ? Query command current value, example: At+almsect? 
Para1,Para2
GPRS/SMS ACTM User manual 
٦١ 
Para1 0 disable function, 1 enable function 
Para2 Interval, the unit is second 
MEMO 
Example: 
Set auto report interval as 8000 seconds 
At+almsect=1,8000 
Returns: 
auto send interval enable 
auto send interval:٨٠٠٠ 
ACTM OK 
Command At+servnum 
Function Set ACTM service center number 
Parameter ? Query command current value, example: At+servnum? It will display 
4 service center number 
Para1,Para2 
Para1 Service center number series number, it is 0,1,2,3 
Para1 Service center number, any numbers. 
MEMO Service center number is data center modem SIM card number or user 
cell phone number; ACTM will send alarm SMS to this number, the max 
number is 4. 
Example: 
Send the second service center number as 13812345678 
At+servnum=1,13812345678 
Returns: 
to(١) :١٣٨١٢٣٤٥٦٧٨ 
ACTM OK 
Command At+servalm 
Function Set service center number receive alarm message 
Parameter ? Query current value, example: At+servnum? 
Para1,Para2,Para3,Para4 
Para1 The first service center number receive alarm SMS, 0 is not 
receive, 1 is receive 
Para2 The second service center number receive alarm SMS, 0 is not 
receive, 1 is receive 
Para3 The third service center number receive alarm SMS, 0 is not 
receive, 1 is receive 
Para4 The fourth service center number receive alarm SMS, 0 is not 
receive, 1 is receive 
MEMO If set service center do not receive alarm SMS, so this number will only 
remote configuration via SMS. 
Example: 
Set only the third service center number receive alarm SMS 
At+servalm=0,0,1,0 
Returns: 
٠,٠,١,٠ 
ACTM OK 
Command At+almparam 
Function Set ACTM SMS alarm resend 
Parameter ? Query current command value, example: At+almparam? 
Para1,Para2,Para3 
Para1 Set center number do not response ACK, the resend SMS
GPRS/SMS ACTM User manual 
retransmissions, if set as 0, disable alarm SMS receipt function, so alarm 
SMS will only send to center number once. 
Para2 Set alarm SMS resend wait interval, the unit is second 
Para3 Set continue alarm SMS interval, the unit is second 
٦٢ 
MEMO 
Example: 
Set retransmissions to be 3, resend SMS interval to be 300 seconds 
At+almparam=3,300,0 
Returns: 
٣,٣٠٠,٠ 
ACTM OK 
Command ACK 
Function SMS receipt, if enable ACK function, center service number should reply 
ACK SMS when receive alarm SMS. 
Parameter ٠٠1 ~ ٩٩٩ alarm SMS series number, all occurred alarm SMS has an 
series number, Data center reply ACK with series number to inform 
ACTM that receive which alarm SMS already. 
MEMO This command is only available through SMS. 
Example: 
Data center send SMS receipt, alarm SMS series number is 001 
ACK -٠٠١ 
Data center send SMS receipt, alarm SMS series number is 2 
ACK -٢ 
Command At+almflag 
Function Set GSM dial up center number and Buzz 
Parameter ? Query command current value, example: At+almflag? 
Para1,Para2 
Para1 before send SMS alarm, ACTM will dial up center number to 
inform alarm occurred. 0 disable function, 1 enable function. 
Para2 Buzz, ٠ turn off buzz, 1 turn on buzz 
MEMO GSM dial function default value is 0, Buzz default value is 0 
Example: 
Set alarm to ring service number, and turn on buzz 
At+almflag =١,1 
Returns: 
wtt[٠] = ١ 
wtt[١] = ١ 
wtt[٠] = ١ wtt[١] = ١ 
ACTM OK 
*Command At+mservip 
Function Set main data center IP address, port 
Parameter ? Query current command value, example: At+mservip? 
Para1,Para2 
Para1 Data center IP address, if using domain name, here should be 
0.0.0.0 
Para2 Port number 
MEMO 
Example: 
Set main data center IP as 20.13.48.6, port as 5008 
At+mservip=20.13.48.6,5008 
Returns:
GPRS/SMS ACTM User manual 
٦٣ 
ip = ٢٠.١٣.٤٨.٦ 
port = ٥٠٠٨ 
ACTM OK 
*Command At+bservip 
Function Set backup data center IP address, port 
Parameter ? Query current command value, example:At+bservip? 
Para1,Para2 
Para1 Data center IP address, if using domain name, here should be 
0.0.0.0 
Para2 Port number 
MEMO 
Example: 
Set backup data center IP as 10.23.48.6, port as 5007 
At+bservip=10.23.48.6,5007 
Returns: 
ip = ١٠.٢٣.٤٨.٦ 
port = ٥٠٠٧ 
ACTM OK 
*Command At+mservname 
Function Set main domain name address 
Parameter ? Query current command value, example:At+mservname? 
Para1 Domain name, any character 
MEMO 
Example: 
Set main domain name address as ACTM.Ariancn.com 
At+mservname=ACTM.Ariancn.com 
Returns: 
server name = ACTM.Ariancn.com 
ACTM OK 
*Command At+bservname 
Function Set backup domain name address 
Parameter ? Query current command value, example:At+bservname? 
Para1 Domain name, any character 
MEMO 
Example: 
Set Backup domain name address as ACTM.Ariancn.com 
At+bservname =ACTM.Ariancn.com 
Returns: 
server name = ACTM.Ariancn.com 
ACTM OK 
*Command At+sleepmode 
Function ACTM sleep function 
Parameter ? Query current command value, example:At+sleepmode? 
Para1,Para2 
Para1 whether enable sleep function 
Para2 the wait time for enter sleep status, the units is second. 
MEMO Detected the specified time that without data transmission RS٢٣٢ 
interface, and no IO alarm occurred, ACTM will go to sleep. The default 
is ٠, disable the sleep function 
Example:
Actm usermanual
Actm usermanual
Actm usermanual

More Related Content

What's hot

Chf100 englishmanual
Chf100 englishmanualChf100 englishmanual
Chf100 englishmanualToàn Huỳnh
 
iTime - Time and Attendance Manual
iTime - Time and Attendance ManualiTime - Time and Attendance Manual
iTime - Time and Attendance Manualamanodirect
 
Zxsdr bs8900 a product description 20101026
Zxsdr bs8900 a product description 20101026Zxsdr bs8900 a product description 20101026
Zxsdr bs8900 a product description 20101026Adeep Asaad
 
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...Advantec Distribution
 
Mc cormick xtx200 tractor service repair manual
Mc cormick xtx200 tractor service repair manualMc cormick xtx200 tractor service repair manual
Mc cormick xtx200 tractor service repair manualfjjksekksemm
 
Mc cormick xtx185 tractor service repair manual
Mc cormick xtx185 tractor service repair manualMc cormick xtx185 tractor service repair manual
Mc cormick xtx185 tractor service repair manualfjskekxswesemm
 
En 600stdprg fwmanual
En 600stdprg fwmanualEn 600stdprg fwmanual
En 600stdprg fwmanualToàn Huỳnh
 
Motorola solutions ap7131 access point installation guide wi ng 5.5 version...
Motorola solutions ap7131 access point installation guide   wi ng 5.5 version...Motorola solutions ap7131 access point installation guide   wi ng 5.5 version...
Motorola solutions ap7131 access point installation guide wi ng 5.5 version...Advantec Distribution
 
Vfd ve m-en_20081231
Vfd ve m-en_20081231Vfd ve m-en_20081231
Vfd ve m-en_20081231Toàn Huỳnh
 
아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼
아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼
아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼HION IT
 
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...Advantec Distribution
 
Toro multi pro 5700-d sprayer service repair manual
Toro multi pro 5700-d sprayer service repair manualToro multi pro 5700-d sprayer service repair manual
Toro multi pro 5700-d sprayer service repair manualjfskemsemm
 
Mobrey mcu900 series
Mobrey mcu900 seriesMobrey mcu900 series
Mobrey mcu900 seriesshahrule
 
Dse4510 dse4520-operator-manual
Dse4510 dse4520-operator-manualDse4510 dse4520-operator-manual
Dse4510 dse4520-operator-manualdeivid_rms
 
DSE 6010/20 - manual operation
DSE 6010/20 - manual operationDSE 6010/20 - manual operation
DSE 6010/20 - manual operationSatria Saputra
 

What's hot (19)

Chf100 englishmanual
Chf100 englishmanualChf100 englishmanual
Chf100 englishmanual
 
Yaskawa V1000 Instuction Manuel
Yaskawa V1000 Instuction ManuelYaskawa V1000 Instuction Manuel
Yaskawa V1000 Instuction Manuel
 
iTime - Time and Attendance Manual
iTime - Time and Attendance ManualiTime - Time and Attendance Manual
iTime - Time and Attendance Manual
 
Zxsdr bs8900 a product description 20101026
Zxsdr bs8900 a product description 20101026Zxsdr bs8900 a product description 20101026
Zxsdr bs8900 a product description 20101026
 
安川A1000系列英文版
安川A1000系列英文版安川A1000系列英文版
安川A1000系列英文版
 
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...Motorola solutions ap6522 m access point installation guide   wing 5.5 versio...
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...
 
Mc cormick xtx200 tractor service repair manual
Mc cormick xtx200 tractor service repair manualMc cormick xtx200 tractor service repair manual
Mc cormick xtx200 tractor service repair manual
 
Mc cormick xtx185 tractor service repair manual
Mc cormick xtx185 tractor service repair manualMc cormick xtx185 tractor service repair manual
Mc cormick xtx185 tractor service repair manual
 
En 600stdprg fwmanual
En 600stdprg fwmanualEn 600stdprg fwmanual
En 600stdprg fwmanual
 
Motorola solutions ap7131 access point installation guide wi ng 5.5 version...
Motorola solutions ap7131 access point installation guide   wi ng 5.5 version...Motorola solutions ap7131 access point installation guide   wi ng 5.5 version...
Motorola solutions ap7131 access point installation guide wi ng 5.5 version...
 
Vfd ve m-en_20081231
Vfd ve m-en_20081231Vfd ve m-en_20081231
Vfd ve m-en_20081231
 
아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼
아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼
아보태블릿PC ARBOR M1042 2D 10.4인치 윈도우즈 헬스케어 태블릿PC 매뉴얼
 
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...
 
Toro multi pro 5700-d sprayer service repair manual
Toro multi pro 5700-d sprayer service repair manualToro multi pro 5700-d sprayer service repair manual
Toro multi pro 5700-d sprayer service repair manual
 
Vfd m en_20100514
Vfd m en_20100514Vfd m en_20100514
Vfd m en_20100514
 
Mobrey mcu900 series
Mobrey mcu900 seriesMobrey mcu900 series
Mobrey mcu900 series
 
Dse4510 dse4520-operator-manual
Dse4510 dse4520-operator-manualDse4510 dse4520-operator-manual
Dse4510 dse4520-operator-manual
 
DSE 6010/20 - manual operation
DSE 6010/20 - manual operationDSE 6010/20 - manual operation
DSE 6010/20 - manual operation
 
Catalog biến tần Inovance MD200
Catalog biến tần Inovance MD200Catalog biến tần Inovance MD200
Catalog biến tần Inovance MD200
 

Viewers also liked

EL LABERINT DE CRETA
EL LABERINT DE CRETAEL LABERINT DE CRETA
EL LABERINT DE CRETAcrisblauras
 
Bloom_Consulting_case study_Latvia
Bloom_Consulting_case study_LatviaBloom_Consulting_case study_Latvia
Bloom_Consulting_case study_LatviaBloom Consulting
 
Bloom_Consulting_case study_Bulgaria
Bloom_Consulting_case study_BulgariaBloom_Consulting_case study_Bulgaria
Bloom_Consulting_case study_BulgariaBloom Consulting
 
Digital country index 16 executive summary
Digital country index 16  executive summaryDigital country index 16  executive summary
Digital country index 16 executive summaryBloom Consulting
 
Bloom consulting us state brand ranking trade 2012
Bloom consulting us state brand ranking trade 2012Bloom consulting us state brand ranking trade 2012
Bloom consulting us state brand ranking trade 2012Bloom Consulting
 
Bloom Consulting Country Brand Ranking Tourism 2011
Bloom Consulting Country Brand Ranking Tourism 2011Bloom Consulting Country Brand Ranking Tourism 2011
Bloom Consulting Country Brand Ranking Tourism 2011Bloom Consulting
 
Bloom Consulting Country Brand Ranking Trade 2013
Bloom Consulting Country Brand Ranking Trade 2013Bloom Consulting Country Brand Ranking Trade 2013
Bloom Consulting Country Brand Ranking Trade 2013Bloom Consulting
 
Bloom consulting country brand ranking trade 2012
Bloom consulting country brand ranking trade 2012Bloom consulting country brand ranking trade 2012
Bloom consulting country brand ranking trade 2012Bloom Consulting
 
Bloom Consulting Country Brand Ranking Tourism 2013
Bloom Consulting Country Brand Ranking Tourism 2013Bloom Consulting Country Brand Ranking Tourism 2013
Bloom Consulting Country Brand Ranking Tourism 2013Bloom Consulting
 
Bloom consulting us state brand ranking tourism 2012
Bloom consulting us state brand ranking tourism 2012Bloom consulting us state brand ranking tourism 2012
Bloom consulting us state brand ranking tourism 2012Bloom Consulting
 
Bloom Consulting Country Brand Ranking Trade 2011
Bloom Consulting Country Brand Ranking Trade 2011Bloom Consulting Country Brand Ranking Trade 2011
Bloom Consulting Country Brand Ranking Trade 2011Bloom Consulting
 
Bloom consulting country brand ranking tourism 2012
Bloom consulting country brand ranking tourism 2012Bloom consulting country brand ranking tourism 2012
Bloom consulting country brand ranking tourism 2012Bloom Consulting
 
Country Brand Ranking © 2014/2015 Tourism Edition
Country Brand Ranking © 2014/2015 Tourism Edition Country Brand Ranking © 2014/2015 Tourism Edition
Country Brand Ranking © 2014/2015 Tourism Edition Bloom Consulting
 

Viewers also liked (15)

EL LABERINT DE CRETA
EL LABERINT DE CRETAEL LABERINT DE CRETA
EL LABERINT DE CRETA
 
Bloom_Consulting_case study_Latvia
Bloom_Consulting_case study_LatviaBloom_Consulting_case study_Latvia
Bloom_Consulting_case study_Latvia
 
What git is
What git isWhat git is
What git is
 
La Cosmogonia
La Cosmogonia La Cosmogonia
La Cosmogonia
 
Bloom_Consulting_case study_Bulgaria
Bloom_Consulting_case study_BulgariaBloom_Consulting_case study_Bulgaria
Bloom_Consulting_case study_Bulgaria
 
Digital country index 16 executive summary
Digital country index 16  executive summaryDigital country index 16  executive summary
Digital country index 16 executive summary
 
Bloom consulting us state brand ranking trade 2012
Bloom consulting us state brand ranking trade 2012Bloom consulting us state brand ranking trade 2012
Bloom consulting us state brand ranking trade 2012
 
Bloom Consulting Country Brand Ranking Tourism 2011
Bloom Consulting Country Brand Ranking Tourism 2011Bloom Consulting Country Brand Ranking Tourism 2011
Bloom Consulting Country Brand Ranking Tourism 2011
 
Bloom Consulting Country Brand Ranking Trade 2013
Bloom Consulting Country Brand Ranking Trade 2013Bloom Consulting Country Brand Ranking Trade 2013
Bloom Consulting Country Brand Ranking Trade 2013
 
Bloom consulting country brand ranking trade 2012
Bloom consulting country brand ranking trade 2012Bloom consulting country brand ranking trade 2012
Bloom consulting country brand ranking trade 2012
 
Bloom Consulting Country Brand Ranking Tourism 2013
Bloom Consulting Country Brand Ranking Tourism 2013Bloom Consulting Country Brand Ranking Tourism 2013
Bloom Consulting Country Brand Ranking Tourism 2013
 
Bloom consulting us state brand ranking tourism 2012
Bloom consulting us state brand ranking tourism 2012Bloom consulting us state brand ranking tourism 2012
Bloom consulting us state brand ranking tourism 2012
 
Bloom Consulting Country Brand Ranking Trade 2011
Bloom Consulting Country Brand Ranking Trade 2011Bloom Consulting Country Brand Ranking Trade 2011
Bloom Consulting Country Brand Ranking Trade 2011
 
Bloom consulting country brand ranking tourism 2012
Bloom consulting country brand ranking tourism 2012Bloom consulting country brand ranking tourism 2012
Bloom consulting country brand ranking tourism 2012
 
Country Brand Ranking © 2014/2015 Tourism Edition
Country Brand Ranking © 2014/2015 Tourism Edition Country Brand Ranking © 2014/2015 Tourism Edition
Country Brand Ranking © 2014/2015 Tourism Edition
 

Similar to Actm usermanual

Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01Advantec Distribution
 
Berges acm-std
Berges acm-stdBerges acm-std
Berges acm-stdTan Ngoc
 
Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01Advantec Distribution
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAdvantec Distribution
 
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAdvantec Distribution
 
Tems investigation 13.1 release note
Tems investigation 13.1 release noteTems investigation 13.1 release note
Tems investigation 13.1 release notetelecom_200
 
Omron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manualOmron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manualYan Zhang
 
Doc sim900 at_command_manua
Doc sim900 at_command_manuaDoc sim900 at_command_manua
Doc sim900 at_command_manuaJuan Fernandez
 
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelSiemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelDien Ha The
 
Siemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eSiemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eDien Ha The
 
Sim800 series at command manual v1.09
Sim800 series at command manual v1.09Sim800 series at command manual v1.09
Sim800 series at command manual v1.09liolio1
 
Ipcam user guide_4.1.3
Ipcam user guide_4.1.3Ipcam user guide_4.1.3
Ipcam user guide_4.1.3sidmar2005
 
Yokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step Guide
Yokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step GuideYokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step Guide
Yokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step GuidePower Specialties, Inc.
 
Honeywell gsmx-install-guide
Honeywell gsmx-install-guideHoneywell gsmx-install-guide
Honeywell gsmx-install-guideAlarm Grid
 
Siemens catalog hmi-td 200 operator interface
Siemens catalog hmi-td 200 operator interfaceSiemens catalog hmi-td 200 operator interface
Siemens catalog hmi-td 200 operator interfaceDien Ha The
 
Gps303 user manual 130920
Gps303 user manual 130920Gps303 user manual 130920
Gps303 user manual 130920Vitor Carvalho
 

Similar to Actm usermanual (20)

Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01Motorola ap 8232 access point installation guide mn000032 a01
Motorola ap 8232 access point installation guide mn000032 a01
 
Dse8620 operators-manual
Dse8620 operators-manualDse8620 operators-manual
Dse8620 operators-manual
 
Berges acm-std
Berges acm-stdBerges acm-std
Berges acm-std
 
Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01Motorola ap 8222 access point installation guide mn000046 a01
Motorola ap 8222 access point installation guide mn000046 a01
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revd
 
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revd
 
Tems investigation 13.1 release note
Tems investigation 13.1 release noteTems investigation 13.1 release note
Tems investigation 13.1 release note
 
Omron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manualOmron PLC cqm1 opearation manual
Omron PLC cqm1 opearation manual
 
Doc sim900 at_command_manua
Doc sim900 at_command_manuaDoc sim900 at_command_manua
Doc sim900 at_command_manua
 
Manual CLP Omron CP1H
Manual CLP Omron CP1HManual CLP Omron CP1H
Manual CLP Omron CP1H
 
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panelSiemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070 touch panel
 
Siemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_eSiemens catalog hmi-tp070_e
Siemens catalog hmi-tp070_e
 
Sim800 series at command manual v1.09
Sim800 series at command manual v1.09Sim800 series at command manual v1.09
Sim800 series at command manual v1.09
 
Ipcam user guide_4.1.3
Ipcam user guide_4.1.3Ipcam user guide_4.1.3
Ipcam user guide_4.1.3
 
Yokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step Guide
Yokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step GuideYokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step Guide
Yokogawa Model GX10/GX20/GP10/GP20 Paperless Recorder First Step Guide
 
LTE_Overview_MTS EMERSON EDUARDO RODRIGUES
LTE_Overview_MTS EMERSON EDUARDO RODRIGUESLTE_Overview_MTS EMERSON EDUARDO RODRIGUES
LTE_Overview_MTS EMERSON EDUARDO RODRIGUES
 
Honeywell gsmx-install-guide
Honeywell gsmx-install-guideHoneywell gsmx-install-guide
Honeywell gsmx-install-guide
 
Siemens catalog hmi-td 200 operator interface
Siemens catalog hmi-td 200 operator interfaceSiemens catalog hmi-td 200 operator interface
Siemens catalog hmi-td 200 operator interface
 
Gps303 user manual 130920
Gps303 user manual 130920Gps303 user manual 130920
Gps303 user manual 130920
 

Recently uploaded

Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...
Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...
Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...srsj9000
 
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一ga6c6bdl
 
1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree
1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree
1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degreeyuu sss
 
如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一
如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一
如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一ga6c6bdl
 
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls KolkataCall Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkataanamikaraghav4
 
(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一
(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一
(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一Fi sss
 
定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一
定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一
定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一ss ss
 
vip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Book
vip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Bookvip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Book
vip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Bookmanojkuma9823
 
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝soniya singh
 
定制(USF学位证)旧金山大学毕业证成绩单原版一比一
定制(USF学位证)旧金山大学毕业证成绩单原版一比一定制(USF学位证)旧金山大学毕业证成绩单原版一比一
定制(USF学位证)旧金山大学毕业证成绩单原版一比一ss ss
 
Real Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCR
Real Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCRReal Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCR
Real Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCRdollysharma2066
 
Call Girls In Munirka>༒9599632723 Incall_OutCall Available
Call Girls In Munirka>༒9599632723 Incall_OutCall AvailableCall Girls In Munirka>༒9599632723 Incall_OutCall Available
Call Girls In Munirka>༒9599632723 Incall_OutCall AvailableCall Girls in Delhi
 
Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...
Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...
Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...nagunakhan
 
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一ga6c6bdl
 
Papular No 1 Online Istikhara Amil Baba Pakistan Amil Baba In Karachi Amil B...
Papular No 1 Online Istikhara Amil Baba Pakistan  Amil Baba In Karachi Amil B...Papular No 1 Online Istikhara Amil Baba Pakistan  Amil Baba In Karachi Amil B...
Papular No 1 Online Istikhara Amil Baba Pakistan Amil Baba In Karachi Amil B...Authentic No 1 Amil Baba In Pakistan
 
原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证
原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证
原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证gwhohjj
 
(办理学位证)多伦多大学毕业证成绩单原版一比一
(办理学位证)多伦多大学毕业证成绩单原版一比一(办理学位证)多伦多大学毕业证成绩单原版一比一
(办理学位证)多伦多大学毕业证成绩单原版一比一C SSS
 

Recently uploaded (20)

Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...
Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...
Hifi Defence Colony Call Girls Service WhatsApp -> 9999965857 Available 24x7 ...
 
young call girls in Gtb Nagar,🔝 9953056974 🔝 escort Service
young call girls in Gtb Nagar,🔝 9953056974 🔝 escort Serviceyoung call girls in Gtb Nagar,🔝 9953056974 🔝 escort Service
young call girls in Gtb Nagar,🔝 9953056974 🔝 escort Service
 
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
 
1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree
1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree
1:1原版定制美国加州州立大学东湾分校毕业证成绩单pdf电子版制作修改#真实留信入库#永久存档#真实可查#diploma#degree
 
如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一
如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一
如何办理伦敦大学伯贝克学院毕业证(BBK毕业证) 成绩单留信学历认证原版一比一
 
CIVIL ENGINEERING
CIVIL ENGINEERINGCIVIL ENGINEERING
CIVIL ENGINEERING
 
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls KolkataCall Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkata
 
(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一
(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一
(办理学位证)加州州立大学北岭分校毕业证成绩单原版一比一
 
定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一
定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一
定制(Salford学位证)索尔福德大学毕业证成绩单原版一比一
 
vip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Book
vip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Bookvip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Book
vip Krishna Nagar Call Girls 9999965857 Call or WhatsApp Now Book
 
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
 
定制(USF学位证)旧金山大学毕业证成绩单原版一比一
定制(USF学位证)旧金山大学毕业证成绩单原版一比一定制(USF学位证)旧金山大学毕业证成绩单原版一比一
定制(USF学位证)旧金山大学毕业证成绩单原版一比一
 
Real Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCR
Real Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCRReal Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCR
Real Sure (Call Girl) in I.G.I. Airport 8377087607 Hot Call Girls In Delhi NCR
 
Call Girls In Munirka>༒9599632723 Incall_OutCall Available
Call Girls In Munirka>༒9599632723 Incall_OutCall AvailableCall Girls In Munirka>༒9599632723 Incall_OutCall Available
Call Girls In Munirka>༒9599632723 Incall_OutCall Available
 
Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...
Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...
Slim Call Girls Service Badshah Nagar * 9548273370 Naughty Call Girls Service...
 
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
 
Papular No 1 Online Istikhara Amil Baba Pakistan Amil Baba In Karachi Amil B...
Papular No 1 Online Istikhara Amil Baba Pakistan  Amil Baba In Karachi Amil B...Papular No 1 Online Istikhara Amil Baba Pakistan  Amil Baba In Karachi Amil B...
Papular No 1 Online Istikhara Amil Baba Pakistan Amil Baba In Karachi Amil B...
 
原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证
原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证
原版1:1复刻斯坦福大学毕业证Stanford毕业证留信学历认证
 
(办理学位证)多伦多大学毕业证成绩单原版一比一
(办理学位证)多伦多大学毕业证成绩单原版一比一(办理学位证)多伦多大学毕业证成绩单原版一比一
(办理学位证)多伦多大学毕业证成绩单原版一比一
 
9953330565 Low Rate Call Girls In Jahangirpuri Delhi NCR
9953330565 Low Rate Call Girls In Jahangirpuri  Delhi NCR9953330565 Low Rate Call Girls In Jahangirpuri  Delhi NCR
9953330565 Low Rate Call Girls In Jahangirpuri Delhi NCR
 

Actm usermanual

  • 1. ١ ACTM User Manual Version 1.٠
  • 2. GPRS/SMS ACTM User Manual ٢ Notice: Copyright The contents of the manual are protected by Chinese law, any organization and/or person cannot copy this manual or part of contents without Arian Ertebat Caspian Co. authorization in written. Trademark ACTM, GPRS ACTM are the logos and trademarks of Arian Ertebat Caspian Co. The other company trademarks and logos in this manual are owned by the owner, Arian does not have the right for those trademarks and logos.
  • 3. GPRS/SMS FAM User manual ٣ Contents CHAPTER ١ INTRODUCTION ........................................................................................................... ٥ ١.١ Objective ..................................................................................................................................................................... ٥ ١.٢ Application ................................................................................................................................................................. ٥ ١.٣ Version......................................................................................................................................................................... ٥ ١.٤ Convention ................................................................................................................................................................. ٦ ١.٥ Technical Support ................................................................................................................................................... ٦ ١.٦ Abbreviations ........................................................................................................................................................... ٧ CHAPTER ٢ PRODUCT INTRODUCTION .................................................................................. ١٠ ٢.١ Introduction ............................................................................................................................................................ ١٠ ٢.١.١ Size ............................................................................................................................................................................. ١١ ٢.١.٢ Accessories ............................................................................................................................................................ ١٢ ٢.٢ System function and feature ............................................................................................................................ ١٢ ٢.٢.١ Main function ........................................................................................................................................................ ١٢ ٢.٢.٢ Part of compatible sensor ............................................................................................................................... ١٤ ٢.٣ Specification ............................................................................................................................................................ ١٥ CHAPTER ٣ INSTALLATION.......................................................................................................... ١٨ ٣.١ ACTM installation and cable connection .................................................................................................... ١٨ ٣.١.١ Antenna and SIM card installation .............................................................................................................. ١٨ ٣.١.٢ RS٢٣٢ configuration and Power cables installation ............................................................................ ١٨ ٣.٢ Sensors installation .............................................................................................................................................. ١٩ ٣.٢.١ DI (Digital Input) sensor installation ......................................................................................................... ٢٠ ٣.٢.٢ AI (Analog Input) Sensor installation ........................................................................................................ ٢١ ٣.٢.٣ DO (Digital Output) device installation ..................................................................................................... ٢١ ٣.٢.٤ TE (Temperature) sensor installation ....................................................................................................... ٢٢ ٣.٢.٥ Wireless Sensor installation ........................................................................................................................... ٢٢ ٣.٢.٦ Camera installation ............................................................................................................................................ ٢٢ ٣.٢.٧ RTU device installation .................................................................................................................................... ٢٣ ٣.٣ Grounding ................................................................................................................................................................ ٢٤ ٣.٤ Power supply .......................................................................................................................................................... ٢٤ ٣.٥ Check the mobile network ................................................................................................................................ ٢٤ CHAPTER ٤ TERMINAL CONFIGURATION ............................................................................. ٢٦ ٤.١ Device Connection ................................................................................................................................................ ٢٦ ٤.٢ Parameter Configuration ................................................................................................................................... ٢٨
  • 4. GPRS/SMS FAM User manual ٤.٣ Parameter Detail ................................................................................................................................................... ٣٢ CHAPTER ٥ TYPICAL APPLICATION ......................................................................................... ٤٨ ٥.١ SMS alarm application ........................................................................................................................................ ٤٨ ٥.٢ ACTM management platform application .................................................................................................. ٤٩ ٥.٣ Transparent data transmission application ............................................................................................. ٥١ CHAPTER ٦ OPERATION ................................................................................................................ ٥٣ ٦.١ Panel Indications ................................................................................................................................................... ٥٣ ٦.٢ ACTM operation Guidance ................................................................................................................................ ٥٤ ٦.٣ Trouble Shooting .................................................................................................................................................. ٥٤ CHAPTER ٧ ATTACHMENT SMS COMMAND ......................................................................... ٥٦ ٧.١ Introduction ............................................................................................................................................................ ٥٦ ٧.٢ Command format .................................................................................................................................................. ٥٦ ٧.٣ Command list .......................................................................................................................................................... ٥٧ ٧.٤ Command detail .................................................................................................................................................... ٥٧ ٧.٥ Alarm information format ................................................................................................................................ ٦٥ ٤
  • 5. GPRS/SMS FAM User manual ٥ Chapter ١ Introduction This chapter describes the manual functions and role, also tells the reader how to read the manual, it's best guidance document for install and use Arian GRPS/SMS ACTM. ١. Objective ٢. Application ٣. Version ٤. Convention ٥. Technical Support ٦. Abbreviations ١.١ Objective This manual mainly ACTM-٩٢٢٠ Quick Start Guide for reference that written to guide ACTM-٩٢٢٠ ACTM installation products. ١.٢ Application This manual applies to a certain computer communications networks, industrial automation control and electronic technical knowledge, network equipment, administrators, engineers and other industrial control which need to use ACTM-٩٢٢٠ ACTM that relevant managers. Applies to version: ACTM-٩٢٢٠ ACTM V١.٠ and below versions. ١.٣ Version According to the market requirement, Arian ACTM-٩٢٢٠ ACTM product-related functions will be adjusted as well as technical improvements. Since the authors have a variety of reasons may cause the contents of revised instructions, the below table show Arian ACTM-٩٢٢٠ product specifications revised at different times and revised version of the reasons for that. Version Modify department Participating departments Date detail
  • 6. GPRS/SMS FAM User manual ٦ ١.٤ Convention For ease of use, fast reading manual, we have some short name, icons, description, security alerts, tips and other conventions are as follows: Convention Description Memo ACTM-922 0 Arian ACTM-9220 GPRS/SMS ACTM Support ٣ DI, ١ AI, ١ DO ports ACTM-922 0 ET8600 series GPRS/SMS ACTM products Support ٧ D, 1 AI, ٤ DO ports, Support Wireless Sensor ACTM GRPS/SMS ACTM Suggestion Installation time-saving tips or experience Appear in this manual installation and testing Notice Prompt the user or reader to pay attention the important information or parameters Appear in this manual operation Warning A serious warning, such as the improper use of the temperatures, voltage, unstable environment Appear in this manual production introduction and installation Attention General warning: prompt the user some illegal operation or improper use of operations ١.٥ Technical Support To allow users to quickly solve difficult problems, get the correct solution for hardware, operating system and installation. The following ways to contact Arian
  • 7. GPRS/SMS FAM User manual ٧ ١.٦ Abbreviations The Manual related abbreviation meaning: APN Access Point Name APP Application ATM Asynchronous Transfer Mode ATM Auto Table Machine AuC Authentication Centre BG Border Gateway BGP Border Gateway Protocol BSC Base Station Controller BSCC Base Station Control Connection BSS Base Station System BSSGP BSS GPRS Protocol BTS Base Transceiver System CDMA Code Division Multiple Access CDR Call Detail Record CGF Charging Gateway Function CSD Circuit Switch Data DDN Digital Data Network DHCP Dynamic Host Configuration Protocol DNS Domain Name System DSC Data Service Center DTU Data Terminal Unit EGP External/Exterior Gateway Protocol EIGRP External/Exterior Internet Group Routing Protocol EMC Electro Magnetic Compatibility ESP Electro Static Precautions ETSI European Telecommunications Standards Institute GGSN Gateway GPRS Support Node GMSC Gateway MSC GPRS General Packet Radio Service GSM Global System for Mobile Communications GSN GPRS Support Node GTP GPRS Tunneling Protocol GTP-id GTP Identity ACTM Fixed Asset Monitor HLR Home Location Register HSCSD High Speed Circuit Switch Data
  • 8. GPRS/SMS FAM User manual ٨ IGMP Internet Group Management Protocol IGRP Internet Gateway Routing Protocol IN Intelligent Network IP Internet Protocol IPv٤ IP version ٤ IPv٦ IP version ٦ IPSEC IP Secure Protocol ISDN Integrated Services Digital Network ISP Internet Service Provider L٢TP Layer ٢ Tunneling Protocol LA Location Area LLC Logical Link Control MAP Mobile Application Part MDNS Mobile Domain Name System MS Mobile Station MSC Mobile Switching Center MT Mobile Terminal MTBF Mean Time between Failures MTTR Mean Time to Recovery N/A Not Applicable NAS Network Access Server NAT Network Address Translation NTP Network Time Protocol O&M Operations & Maintenance PAP Password Authentication Protocol PCF Packet Control Function PDP Packet Data Protocol PDN Packet Data Network PDSN Packet Data Service Node PLMN Public Land Mobile Network POS Point of Sales PTM-G Point-to-Multipoint Group Call PTM-M Point-to-Multipoint Multicast QoS Quality of Service RA Routing Area RADIUS Remote Authentication Dial In User Service RIP Routing Information Protocol RSC Register Service Center RTOS Real Time Operating System RTP Real-time Transport Protocol
  • 9. GPRS/SMS FAM User manual ٩ RTU Remote Terminal Unit SCADA Supervisory Control and Data Acquisition SGSN Serving GPRS Support Node SIM Subscriber Identify Module SMS Short Message Service SMSC Short Message Service Center SNMP Simple Network Management Protocol STK SIM Tool Kits TCP Transmission Control Protocol TDMA Time Division Multiple Access TMN Telecommunication Managed Network TTL Time to Live UDP User Datagram Protocol UIM User Identify Module UMTS Universal Mobile Telecommunication System USSD Unstructured Supplementary Service Data UTK UIM Tool Kits VLR Visitor Location Register WAN Wide Area Network WAP Wireless Application Protocol WDDN Wireless Digital Data Network
  • 10. GPRS/SMS ACTM User manual ١٠ Chapter 2 Product Introduction This chapter describes the overview of the ACTM system, function and specification, by reading this chapter, the reader can understand the ACTM system configuration, product accessories and detail function. ١. Introduction ٢. System function and feature ٣. Specification ٢.١ Introduction GPRS network theoretically can provide a maximum bandwidth ١٧١.٢Kbps, actually, it works at ٤٠~١٠٠Kbps bandwidth (it depends on service provider’s operation policy). As we know, GPRS is packet based network which provides TCP/IP communication channel. GPRS/SMS ACTM (Fixed Asset Monitoring) is an enhanced GPRS/SMS messenger (GPRS or CDMA service optional) which integrated with I/O port, RTU (Remote Terminal Unit), Relay, Sensor functions, it can help people to monitoring, control,SMS alarm the remote devices. GPRS/SMS ACTM main apllication filed is Home Security, Power grid automatization, industrial monitoring, traffic management, weather, finance, Basic Environmen protecting, colliery, Oil field etc, especially, apply in security, remote control. Implement transparent data transmission over GPRS/SMS network. The Typical system diagram is as below:
  • 11. GPRS/SMS ACTM User manual ٢.١.١ Size ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram, according the different applications, there are mounting holes on both sides to meet the needs of a variety of industrial applications. ACTM-٩٢٢٠ ACTM fixed shape and size of installation position refer to the below diagram, according the different applications, there are mounting holes on both sides to meet the needs of a variety of industrial applications. ١١
  • 12. GPRS/SMS ACTM User manual ١٢ ٢.١.٢ Accessories In order to protect products during shipment, ACTM-9220 GPRS/SMS ACTM has been packed properly. You may need to keep the packing materials for reshipping after you open the pack box. ACTM-9220 ACTM package includes:  ACTM-9220 ACTM ١ piece (Packed according to P/O)  +12V Power adapter ١ piece  2.5 meters antenna ١ piece  User manual ١ Piece(CD-ROM)  Qualified & Repair Card ١ piece Optional Accessories:  9Dbi High gain magnet antenna  Yagi antenna  Fixed antenna  Cascading Cable(SMA interface)  Configuration and firmware update cable After you open the box, you should count it carefully with your purchase order. ٢.٢ System function and feature ٢.٢.١ Main function  Industrial Design GPRS/SMS ACTM is industrial design which built-in watchdog chipset to ensure the system work continuously, Watchdog monitoring the GPRS module and CPU all the time, if the GPRS module or CPU does not response for long time, ACTM will restart automatically. ACTM is very suitable for long-term continuous work applications.  Support Wireless Sensor ACTM-٩٢٢٠ GPRS / SMS ACTM supports RF wireless sensors, connected through RF٤٣٣.٩٢Mhz frequency with wireless sensors, ٨-way wireless zones, support ٤٠ wireless sensors, and real-time monitoring of the state of the sensor, when the sensor battery is low or disconnect the connection, tamper switch, ACTM will send alarm information.  Transparent data transmission GPRS/SMS ACTM provides full transparent data transmission channel through RS٢٣٢ interface it use for connect different types of PLC, RTU which extend the scope of ACTM application, and better services for users.  Main and backup data center
  • 13. GPRS/SMS ACTM User manual GPRS/SMS ACTM support main and backup data center, user can set both main data center ip address or domain name, when ACTM fail to connect with main data center, it will try to connect backup data center automatically.  Embedded Li-battery and Temperature sensor GPRS/SMS ACTM built-in ١٠٠٠mA Lithium battery, it can work for ٦ hours if the external power supply cut off. Also, ACTM will send alarm message to notify the user that the external power supply was cut off. the built-in temperature sensor can real-time monitoring of environment temperature, ACTM also support t external digital temperature sensor that monitor user’s device surface temperature, when the temperature lower or higher than the specified value, ACTM will send alarm message, when the temperature returned to normal, ACTM will send notice message to user also.  User-define alarm SMS GPRS/SMS ACTM support User-define alarm SMS, according to alarm port status, ACTM will choose the user pre-define content, and send to user mobile phone by SMS, it’s easy for user to understand alarm message.  I/O status Buffer ACTM has NVRAM buffer to save the I/O status data during GPRS/SMS tunnel problem, when the GPRS/SMS tunnel return to normal, ACTM will send buffer all data immediately, NVRAM has feature for save data even power lose, so even ACTM power lose, the buffer data will still save.  Ring and SMS alarm ACTM support ring and SMS for sending alarm message, when the alarm occurred, ACTM will start ring for ١٠ seconds, and then send alarm SMS to users. Users also can remote setting and control ACTM by SMS.  SMS receipt To ensure user receive the alarm messages, user can set the alarm SMS resend frequency, unless the alarm clear or receive ACK message receipt from user phone, ACTM will repeat to send alarm SMS by Specified frequency and interval.  Alarm clear message All of ACTM I/O port can be set the alarm clear message, when the port alarm status clear, ACTM will send alarm clear SMS to notice user.  Regularly report the I/O status ACTM-٩٢٢٠ ACTM support auto send I/O port status by specified time, after user set the time, ACTM will send the port status on specified time daily. ١٣  DO port programmable output ACTM DO (digital output) port supports programmable output, according to the requirement of user site, the level of output level, switching time, times would be programmable.  Zone type ACTM DI ports support zone type setting which can be set to as common zone, delay zone, intelligent zone, emergency zone, home zone, according to the user site conditions and sensor type, set the correct zone type to prevent false alarm, missing alarm.  GPRS SMS work at the same time
  • 14. GPRS/SMS ACTM User manual ACTM communication through GPRS to data center, at the same time, ACTM also can occur SMS to the user's mobile phone, so that’s insuring the user receive the alarm message via GPRS and SMS.  Timing arm/disarm, password arm/disarm ACTM support timing arm/disarm function, it can perform a specified time every day to arm/disarm; ACTM also support any mobile phone number via a password to arm/disarm, after the instruction is executed successfully, ACTM will arm/disarm information to the administrator phone as well.  Camera capture picture ACTM provides the interface to connect with camera, real-time remote image capture, with the ACTM IO ports, real-time capture images when an alarm is generated, and sent to the data center; ACTM can be set to a fixed time interval for continuous capture images as well.  MODBUS Protocol programmable output ACTM provides storage and forwarding the command functions of the MODBUS protocol, users can pre-save the common command to ACTM, and ACTM will send the command PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically. ١٤  Clock synchronization ACTM support clock synchronization; it can read the clock from SMS or get clock from management platform by GPRS.  Cell phone and PC be Data service center GPRS/SMS ACTM supports cell phone and PC server to be data service center, if PC to be service center, please use Arian ACTM management platform software, it supports SQL data base, Google map etc. it can monitor thousands ACTM via GPRS; if the stations exceeds ٥٠٠ points, we suggest use ACTM management platform.  Graphical configuration software ACTM-٩٢٢٠ GPRS/SMS ACTM provide full graphical software configuration, easy to use, and supports import or export configuration file; so users just simply click a few icons to quickly setup ACTM system.  Worldwide applications GPRS/SMS ACTM has broad range of applications; it can be used in industrial remote monitor, security, meteorology, environmental protection, water conservancy, electric power industries. To more suitable of industrial M٢M applications, Arian can quickly modify the software and hardware according to customer requirements. ٢.٢.٢ Part of compatible sensor The below item is part of ACTM compatible sensors: Float Water Level Sensor Temperature Sensor Pressure Sensor Magnetism Detector Speed Sensor Flow Sensor Infrared Detector Shock Sensor Wind Sensor Smoke Sensor Lighting Sensor Gas/LPG Detector
  • 15. GPRS/SMS ACTM User manual ١٥ Humidity Sensor Dynamo Sensor Water immersion Sensor Relay Microwave Motion Sensor Voltage Sensor Horizontal Sensor Emergency Button Sound & Flash Siren ٢.٣ Specification Basic  GPRS Dual Bands ٩٠٠Mhz/ ١٨٠٠Mhz  GPRS Quad Bands ٨٥٠/٩٠٠/١٨٠٠/١٩٠٠Mhz (Optional)  CDMA ٨٠٠mhz (Optional)  Dual SIM Slot (Optional)  Self-define re-connecting interval  Clock synchronizing  Support external temperature sensor  Embedded Temperature Sensor  Support Temperature verify  I/O status buffer  Self-define report I/O status daily  Self-define online report interval  AI and the TE port upper and lower limits  DO port programmable output  DI port zone type setting  Timing, password arm/disarm  GPRS SMS work at the same time  MODBUS Protocol programmable output  Optical isolation terminal  Smart power management  Automatic power supply detection  Li-Battery inside (Optional)  Support ٢ DI pulse input (Optional)  Support GPS (Optional)  Support Max ١٦ Temperature sensors (Optional)  Support camera to Photograph  Support alarm link to photograph  PC based configuration tool  Real time OS, steady system  Watch dog design, ensure ACTM alive  Low consumption, industrial design  Fully type approved with ETSI GSM Phase ٢+ standard  Enhanced EMC/EMI design GPRS  Industrial class GPRS wireless module  Embedded PPP, TCP/IP Stack  Support main and backup service center  Support TCP/IP and UDP/IP  Transparent data transmission  Support RS٢٣٢ interface for data transmission
  • 16. GPRS/SMS ACTM User manual ١٦  Supports DNS and dynamic data service center IP address  Support continually or sleep work mode  Support Carrier public & special APN  Work with ACTM management platform  Remote monitoring and control SMS  Support SMS and Ring Alarm  Set defense by SMS  Self-define SMS alarm message  Alarm/Disarm by SMS  Automatic send alarm SMS to mobile phone when alarm is triggered  Support ٤ service center number, and customized setting for center  SMS query ACTM signal strength  DO Relay triggered by alarm or SMS  Automatic SMS alarm when data above or below the preset levels  Support SMS remote configuration  Alarm clear message  Alarm SMS receipt and acknowledgement RF Wireless  Frequency: ٤٣٣.٩٢Mhz  Wireless transmission distance: ١٠٠meter standard environment  Support sensor low battery alarm  Support sensor Tamper alarm  Support sensor disconnect alarm  Real-time monitoring of sensor status  Anti-RF interference  ٨ wireless zones  Supports ٤٠ wireless sensor  Support ٥ remoter  Support wireless zone type setting Interface  Antenna: ٥٠Ω/SMA Female  SIM/R-UIM: ٣V  Configuration: RS٢٣٢  Data: RS٢٣٢ (RS٤٨٥, Ethernet Optional)  DI: ٣ Ports (٠-٣V False, ٣-٣٦V True)  AI: ١ Port  DO: ١ Port  TE: ٢ ports Note: DI = Digital Input AI = Analog Input DO = Digital Output TE = Temperature Power  Voltage: ١٢V~١٨VDC (١٢~٣٠V Optional)
  • 17. GPRS/SMS ACTM User manual ١٧  Default Voltage: DC١٢V  Consumption: Communication: ١٢٠mA@+١٢VDC Idle: ٣٠mA@+١٢VDC Others  Dimension: ٩٠mmx٦٢mmx٢٢.٥mm  Weight: ١٩٠g  Operation temperature: -٤٥~+٧٥ºC  Storage temperature: -٥٥~+٨٥ºC  Relative humidity: ٩٥% (no-condensing)
  • 18. GPRS/SMS ACTM User manual ١٨ Chapter 3 Installation This chapter describes in detail about ACTM system hardware installation, cable and sensor connections, by reading this chapter, the reader should be able to complete the ACTM hardware installation. ١. ACTM installation and cable connection ٢. Sensors installation ٣. Grounding ٤. Power supply ٥. Check the mobile network ٣.١ ACTM installation and cable connection GPRS/SMS ACTM should be installed and configured properly before putting it in service. The installation and configuration should be done or supervised by Arian qualified engineer. Attention: Do not install GPRS/SMS ACTM or connect/disconnect its cable when it is power on. 3.1.١ Antenna and SIM card installation Using the antenna or other sharp items to click the top of the yellow dots SIM card connector, SIM card slot will automatically pop up, please put SIM card into the slot, and push the SIM card connector to the slot. The picture shown is as below: 3.١.٢ RS232 configuration and Power cables installation ACTM-9220 ACTM signals and power supply is connected by industrial class pluggable terminals, ٣.81mm, ١٢Pin, and ١٤~٢٤AWG outlet cable is recommended. Each line definition refers to the following diagrams and tables. Also, you can find outlet cable definition table at top of ACTM-9220 ACTM cover. As shown in the following diagrams and tables, peel off the cable end about ٧mm and connect each terminal and cable (١٤~٢٤AWG cable recommended. Make sure that you have connected the terminals without any mistake.
  • 19. GPRS/SMS ACTM User manual ١٩ ٧mm 14~24AWG ٧٧mm PIN Signal name Description MEMO Vin +5~18V Power Vin, recommend 12V 80mA@12V GND GND Power GND Vout Power Output This PIN voltage is same Vin DI1 Digital Input 1 Voltage range: 0-36V DI2 Digital Input 2 Voltage range: 0-36V DI3 Digital Input 3 Voltage range: 0-36V GND GND Signal GND; common with user’s device; RS232 GND AI1 Analog Input 1 Voltage range: 0-10V DO1 Digital output 1 Default is low level This PIN voltage is same Vin TX Send data RS232 TX RX Receive data RS232 RX UG Software Upgrade After connect with GND, ACTM will enter to software upgrade status Attention: The power cable should be connected correctly. We suggest double check before switch it on. Wrong connections may destroy the equipment. Power terminals: Pin ١ and Pin ٢; Here: Pin ١ is Power input “Vin” (+٥~+١٨VDC), Pin ٢ is”GND”. ٣.٢ Sensors installation ACTM-9220 ACTM Provides 3 DI ports ,1 AI port,1 DO port. The sensors installation is as below:
  • 20. GPRS/SMS ACTM User manual 3.2.1 DI (Digital Input) sensor installation DI sensor only two states, high level (٣-٣٦V) and low level (٠-٣V). There are ٢ kinds of DI sensors, switching and voltage type.  Switch DI Sensor The switching DI sensor is like a simple switch, it only has ٢ statuses, ON or OFF. Connect the switch sensor ٢ signal lines to ACTM Vout pin and DI pins. it can be connected to multiple sensors; the common switching DI sensor such as Magnetic sensor, float level sensors, infrared sensors, pressure sensors, gas sensors, emergency buttons etc. the connections diagram as shown below: To achieve the alarm linkage, alarm equipment and DI port can be parallel interfaces to achieve the alarm linkage. When Magnetic sensors have closed, the sound and light alarm simultaneously closed, as follows picture:  Voltage DI Sensor The Voltage DI sensor provide DC voltage, connect the sensor Pin+ to ACTM DI pin, GND to ACTM GND, the common voltage DI sensor such as water immersion sensor, the connection diagram as shown below: ٢٠
  • 21. GPRS/SMS ACTM User manual 3.2.2 AI (Analog Input) Sensor installation  Voltage AI Sensor Voltage sensor provide a voltage to the ACTM AI ports that required voltage between ٠-١٠V, connect sensor Vout to the ACTM AI pin, GND connect to ACTM GND, the commonly used voltage AI sensor such as current sensor , Voltage sensor, fuel sensor etc. shown as follows:  resistance AI sensor Resistance AI sensor is like a variable resistor, such as resistance Humidity sensors, ١٠kΩ is the standard resistance; its resistance to humidity changes as the actual changing. Connect the sensor 2Pin to the ACTM AI and Vout pin. The commonly resistance AI sensor such as humidity sensor and so on. 3.2.3 DO (Digital Output) device installation ACTM DO port provides the same voltage a Vin pin, and not more than ٢٠٠mA of current output. DO port can be used to control remote devices such as relays, photoelectric alarm, and alarm speakers. The installation diagram showed as below: ٢١
  • 22. GPRS/SMS ACTM User manual Attention: When the external power supply disconnect, ACTM will using internal battery power, the internal lithium battery supply voltage as ٣.٧V, so the DO port cannot provide ١٢V voltage, only output 3.7V voltage, so DO port will unfunctional. DO port provides maximum ٢٠٠mA output current, if use DO port to control equipment which more than ٢٠٠mA current, it should be added relay between ACTM and equipment. 3.2.4 TE (Temperature) sensor installation ACTM provides two TE ports, TE٢ is the built-in NTC thermistor, the user can directly use it without installation; TE٢ is an external digital temperature interface, the digital temperature sensor connect to TE٢ port, it can be use for monitor equipment surface temperature, ambient temperature, water temperature, oil temperature and so on. The installation diagram showed as below: 3.2.5 Wireless Sensor installation ACTM supports wireless sensors, wireless sensor using ٤٣٣MHZ RF to connect with ACTM controller, just assembled wireless sensor battery, and then through ACTM configuration tool to registered wireless sensor, the sensor would be connect to ACTM successfully. 3.2.6 Camera installation ACTM supports camera capture picture function, camera connect to ACTM via RS232 port, DC 12V Power, the installation diagram showed as below: ٢٢
  • 23. GPRS/SMS ACTM User manual Please connect camera cable to ACTM according to the above figure cable color: Camera ACTM Green ----> RX Yellow ----> TX Black ----> GND Red ---- > Vout After finish the ACTM and camera cable connection, we need to complete the implementation of the following actions:  Turn OFF the debug information display on the configuration software  Turn ON the camera function on the configuration software  Disconnect the ACTM configuration cable to PC (ACTM mini-USB side)  Restart ACTM Notice: ACTM and the camera both is connected via the RS٢٣٢ interface, the camera can not be used when the ACTM at configuration status. ACTM configuration cable must be disconnecting, and then the camera should be work properly. 3.2.7 RTU device installation ACTM provides RS٢٣٢ interface to connect other RTU device; it’s a three-line, installation diagram shown as below: ٢٣
  • 24. GPRS/SMS ACTM User manual ٣.٣ Grounding To ensure a safe, stable and reliable ACTM-9220 GPRS/SMS ACTM operation, the ACTM cabinet should be grounded properly. Connect the ACTM cabinet to site ground wire at the ground point ٣.٤ Power supply ACTM-9220 ACTM is designed with advanced power management technologies; it can operate standalone. The DC power is supplied via pluggable terminal Pin ١ (Vin) and Pin ٢ (GND). Detail definitions refer to above tables. Notice: About Power Supply: When ACTM-9220 GPRS/SMS ACTM communicates with base station, surge current will exceed normal current. Therefore, margins ٥ times over normal current may be required for external power supply. Normally, ACTM-9220 ACTM input power supply is +٥~+18VDC, in most cases, ١٢VDC/١A is recommended. Power supply ripple should be less ٣٠٠ mV. ٣.٥ Check the mobile network Connect all signal and power cables, and double check it, connect antenna, insert a valid SIM and switch on power. ACTM-9220 “PWR” LED will light up. After around 30 seconds, If “NET” and “DATA” LED is flashing at same time (ON for 2 seconds then OFF for 2 seconds), it means the ACTM-9220 ACTM is working normally. If the “DATA” LED is flashing, it means there are data stream. If the “NET” LED lights up, it means that the ACTM-9220 ACTM has found and logged on mobile network. ٢٤
  • 25. GPRS/SMS ACTM User manual Warning: All cables should be connected correctly before switch on. Antenna should be connected before switch on, otherwise it may cause radio module problem ٢٥
  • 26. GPRS/SMS ACTM User manual ٢٦ Chapter 4 Terminal Configuration This chapter describes in detail about ACTM configuration software, by reading this chapter, the reader should be able to know the function of ACTM, and change the configuration according actual requirement. ١. Device Connection ٢. Parameter Configuration ٣. Parameter Detail ٤.١ Device Connection ACTM graphical configuration software, it's easy to use and operation. Before the formal operation on the device, ACTM-٩٢٢٠ ACTM must be set to correct parameters. ACTM supports two ways to communication with PC. Notice: ACTM provide power switch (close the green socket), turn the power switch to the ON, ACTM will power ON and start run.  By using Arian configuration cable connect to ACTM Console port, which has upgraded firmware button (Blue Button) on the cable, when press in the button, ACTM will enter to firmware upgrade mode, and all of 4 LED will be ON; when press out the button, ACTM will enter to normal work mode, the Power LED will be ON, Data LED will be flash. the connection diagram shown as Below:
  • 27. GPRS/SMS ACTM User manual  Connect PC's RS٢٣٢ interface to the ACTM terminals RX, TX, GND pin, if Connect ACTM terminal UG and GND pin together, ACTM will enter the software upgrade status. the connection diagram shown as Below: ٢٧
  • 28. GPRS/SMS ACTM User manual ٤.٢ Parameter Configuration A. Connect ACTM According the above two ways to connected PC and ACTM, and installed ACTM configuration software on the PC. Switch ON ACTM power, start ACTM configuration software on the PC, click the interface in the navigation bar of the "OPEN “button, if the connection is successful, the software will automatically connect with the ACTM, and ACTM read all configuration information. If the connection is not successful, click on the navigation bar "PORT" button, select the correct port number, baud rate is ١١٥٢٠٠, and then click "OPEN" to retry the connection. When the information bar shows "Login Successful", it means that the configuration software and ACTM-٩٢٢٠ ACTM connection is successful, the picture shown as follows: ٢٨
  • 29. GPRS/SMS ACTM User manual Attention: After Configuration software connected ACTM successful, it will read ACTM configuration information and refresh automatically, this process may takes about ٢٠ seconds, and will slightly pause is normal. Using the configuration software, please turn OFF the ACTM debugging information, the debug information will affect the configuration software to read the ACTM information. When the SIM card is not inserted, or ACTM in the TCP / UDP mode, if the GPRS connection is not successful that ACTM will automatically restart, and then configure software will appear that failure to read/set parameters, just simply click "Connect" button on the navigation bar, ACTM will connect again. B. Query Parameter For query ACTM parameters, just click the optional checkbox in the left window (multiple choice), then click the navigation bar "Query" button, the configuration software will query the ACTM parameter information, and refresh the option box. Notice: if didn't tick any parameter options box, and click on "Query" button, ACTM will returns the current status values of all the IO ports in the information bar, this feature is easy to test sensor, and real-time query IO port status. C. Set Parameter To change the ACTM parameters, just click the optional checkbox in the left window (multiple choices), then modify the parameter value detail, and click the navigation bar "Save" button, the configuration software will save the parameter information to the ٢٩
  • 30. GPRS/SMS ACTM User manual ACTM, if save successful, it will show "the parameter have been save successful" in the message window ", the picture shown as below: Notice: If didn't tick any parameter options box, and click on "Save" button, ACTM will implement save command. After registrater the wireless sensor, you need by clicking on the "Save" button to execute the save. D. Series Port Configuration Click the navigation bar "Port" button to open the serial port configuration window, it need to select the appropriate connection port and the baud rate to connect to ACTM, the picture shown as below: Notice: The default login password is ٠٠٠٠٠٠, please do not change this password if it's not necessary; once change the parameter on the configuration page, you should also change the same login password here, otherwise ACTM will not able to login. ٣٠
  • 31. GPRS/SMS ACTM User manual E. Series Port Window The serial window is for testing and troubleshoots, click on the navigation bar "serial window" button, the window from the parameter window into the serial port window, for return parameter window, and just click "parameter window" button on the navigation bar. Attention: Send commands to the ACTM in the serial port window may bring unexpected problems; usually, please do not enter to the serial port window mode. F. Common Parameter Click the navigation bar "Common setting" button to open the common parameter settings window, you can select the frequency parameter to the common parameters window, and it’s for mass and quickly configuration ACTM. the picture shown as Below: G. All Click the navigation bar "All" button, it will select all option on the Parameter Configuration page, that’s easy for user to operation. H. Clock Synchronization Click the navigation bar "Clock Synchronization" button, ACTMcfg software will ready the computer clock information, and write to ACTM. Notice: ACTM supports three way to clock synchronization: configuration software, SMS, Data center via GPRS; by the configuration software and SMS clock synchronization, when ACTM power lose, the clock will automatically be zero, and need to clock synchronization again; by the GPRS mode, ACTM will clock synchronization by each login data center, we recommend using GPRS for clock synchronization. ٣١
  • 32. GPRS/SMS ACTM User manual I. Restart Click the navigation bar "restart "button, ACTM will immediately restart, and show "restart the device successful "in the information bar, about ١٠ seconds, click the "Connect" button , software will try to connect ACTM again. J. Default Parameter Click the navigation bar "Default “button, ACTM will revert all parameters to the default. Attention: This operation will restore ACTM parameters to factory state, it need to re-set ACTM parameters in order for ACTM to work again. K. Import/Export Import / export feature is mainly used for quickly and easy to mass ACTMs, click the menu bar "File “option under the "Export ", you can export the current configuration to be INI file. Click menu bar "File “option under the "Import ", then select the INI file which saved before, you can import the original configuration files in the current software Suggestion: "Import / Export" function can be used with the "Common Parameters” together, after the import parameters, click "Common Setting" and "All" button, then click “Save" button, this way will quickly save all of parameter you need. Attention: During "Import / Export “parameter, due to software will read/write large data, software may pause a few seconds, its normal. ٤.٣ Parameter Detail A. SIM Para. Click the left mouse button on "SIM Para."; enter to the SIM card parameter setting, the picture shown as below: ٣٢
  • 33. GPRS/SMS ACTM User manual  APN Name (APN) Follow the prompts to enter information into the access point name (access point name cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" button on the navigation bar ", the message bar will show "parameters set successfully". Attention: Access Point Name (APN) is mobile operator to provide users with different access network types; you must query the APN name from the local operator, and then modify the APN name on the ACTM, so ACTM will able to connect to local GPRS network.  Username Login GPRS service username, usually empty  Password Login GPRS service password, usually empty B. RTU Connection Setting Click the left mouse button on "RTU Setting"; enter to the RTU connection setting, the picture shown as below: ٣٣
  • 34. GPRS/SMS ACTM User manual  Band Serial port configuration, selectable baud rate is ٣٠٠-١١٥٢٠٠. Attention: This band is same band with configuration software connect to ACTM, if you modify this band rate, simultaneously modify configuration band, then the configuration software able to connect the ACTM.  Data bit Serial port configuration, data bits is ٨-bit usually  Stop bit Serial port configuration, usually is ١ stop bit  Parity bit Serial port configuration, parity bit is NONE usually  Data packet interval ١٠٠-٢٠٠٠ms, RTU Packet Minimum time interval, the default is 300ms  Customized RTU Command ACTM can end command to RTU automatically, command is hex code, no space between commands, for example: the command is ٥٥ ٤٥ ٠٠ ٠١ ٠٠ ٢٣, so just fill in as ٥٥٤٥٠٠٠١٠٠٢٣  Data Header Add data head on sending RTU data to center; Format: ID(Max ١٦ byte ASCII code)@time,date(٦ byte, HEX format)@ data (hex code)  Command Interval Interval for sending RTU commands within group  Group commands Interval Interval for sending RTU commands between groups  SMS RTU At the SMS mode, ACTM can forward RTU data via SMS to the data center and pass-through SMS data from data center to the RTU seires port C. IP Channel Setting ٣٤
  • 35. GPRS/SMS ACTM User manual The Parameter is for ACTM work on TCP/UDP mode; click the left mouse on"IP Channel"; enter to the IP parameter setting, the picture shown as below:  Main IP address x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center through domain name.  Main Domain Name Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center.  Main Port ١-٦٥٥٣٥, Main data center IP port  Backup IP address x.x.x.x, Backup data center IP address. if ACTM cannot connect to main IP address many times, ACTM will try to connect backup IP address.  Backup Domain Name Backup data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center.  Backup Port ١-٦٥٥٣٥, Backup Data center IP port.  Heartbeat Interval ٠-٦٥٥٣٥ Seconds, Heartbeat interval, if value is 0, ACTM will don’t send heartbeat data. The default interval is 40 seconds. The heartbeat is link maintain parameter, that is the heartbeat interval, ACTM periodically sends the fixed format of heartbeat packets to data center, which has maintained a link connection. This is because the network operators in order to prevent terminals linked to the Internet, but don't transferring data, taking the wireless network resources, as found in the terminal does not transmit data within a certain period of time, it will kick off the assembly line to the terminal.  Work mode ٣٥
  • 36. GPRS/SMS ACTM User manual GPRS transmission work mode, IO protocol mode will send&receive data through Arian protocol, and it use for connect ACTM management platform; transparent mode, using the transparent data channel, and sends heartbeat packets, it’s for connect to other platform or data center.  Sleep Mode For save GPRS data transmission, ACTM provide 2 kinds of online solution; always online, ACTM will online GPRS all the time; Sleep mode, ACTM will wait for specified time, if there is no alarm and no data transmission, GPRS will automatically be offline, however, it can be activated by SMS or ring  Offline interval ٠-٦٥٥٣٥ Seconds, ACTM offline waiting time, the default is 300 seconds.  Reconnection Interval ٠-٦٥٥٣٥Seconds, IP channel failure or reconnect after sleep time interval, if set to ٠, ACTM will don't try re-connect, only wake-up can make ACTM on-line, the default value is 300 seconds.  A group of the number of re-connect 一Set to ٠, no change to backup channel, only try to connect the main channel  A group of reconnection interval 一A group of reconnection interval, Seconds  Two groups of reconnection interval Two groups of reconnection interval, Minute!!! The default is 10 minutes.  Login attempt times Set as ٠, ACTM only send a registration packet once, Data center is not neccessary to reply registration ACK package; ١ to ١٠, Data centers must respond to the registration ACK package, otherwisem, ACTM will disconnect and reconnect  Heartbeat ACK According to the GPRS signal unstab area, we can enable the heartbeat ACK function. If ACTM did not receive heartbeat ACK packets from data center as ٣ times, ACTM will disconnect the link and try to reconnect.  SMS Backup For the GPRS network often abnormal area, we can enable SMS backup function, when the GPRS link is disconnect, ACTM will also send a message via SMS to the data center; When GPRS recovery, ACTM will send this information to the data center again. D. SMS Channel Setting The parameter is for ACTM work on SMS mode, click the left mouse button on "SMS Channel "; enter to the SMS Channel parameter setting, the picture shown as below: ٣٦
  • 37. GPRS/SMS ACTM User manual  Service Number For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please add country code on the front, the number is for receive alarm SMS from ACTM, and remote control ACTM through SMS.  Service Number Mode The Service number supports 4 modes: Alarm mode, this number only receive alarm SMS, but it can not using SMS for remote settings ACTM. Alarm+Config mode, ACTM send alarm SMS to this number, the number can be remote control ACTM as well. Config mode, this number only for remote config ACTM, it cannot receive alarm SMS. Administrator mode: This number supports Alarm + SMS all functionality, and receive all arm and disarm information via SMS.  Daily report ٠٠:٠٠-٢٣:٥٩, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable.  Report at specified intervals ٠٠:٠٠-٢٣:٥٩, ACTM send IO port status in specific time daily; value ٠٠:٠٠ is disable  Alarm Mode For real time inform user about alarm, ACTM support 3 kinds of alarm mode. SMS mode, ACTM only send alarm SMS; Ring mode, ACTM only Ring; SMS+Ring mode, ACTM will ring for ٦٠ seconds, then send alarm SMS.  SMS Alarm Content For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the alarm happen, ACTM will send the pre-set SMS to service number. customize mode, ACTM will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send alarm SMS according Arian protocol E. I/O Port Setting The parameter is for ACTM I/O port setting, click the left mouse button on "I/O port setting"; enter to the I/O parameter setting, the picture shown as below: ٣٧
  • 38. GPRS/SMS ACTM User manual Attention: Configuration software can set ACTM-9220 and ACTM-9220 product parameter, ACTM-9220 provide 3 DI, 1 AI, 1 DO, 2 TE ports, ACTM-9220 provide 7 DI, 4 AI, 4DO, 2 TE Ports. When set the ACTM-9220 I/O ports, just disable port alarm for DI4, DI5, DI6, DI7, AI, 2, AI3 etc. if enable the not exist port alarm, there may be some illegal value, the false alarms may happen.  DI Alarm Status Low level, when port is low level, alarm happen; High level, when port is high level, alarm happen; Status change, when the port status change, alarm happen; Pluse input, if connect to pluse input device, choose this option; The default is Disable alarm.  DI Zone Type Normal Zone: Start detect after arm immediately. Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for PIR montion sensor, in case the wrong alarm. Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for connect to emergency button, smoke sensor etc. Home Zone: This zone can be turning off by Home button of remote controller; when user at home, he can use this function for disable some sensor inside home.  DI Zone Type Normal Zone: Start detect after arm immediately. Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for PIR montion sensor, in case the wrong alarm.  DI trigger duration ٣٨
  • 39. GPRS/SMS ACTM User manual Unit: ١٠٠ms, default value is ٢, so the duration is ٢٠٠ms. When DI port achieves alarm value, and keeps after specified duration, occur alarm. According to part of senors (such as float level sensors, pressure sensors), the value may be hovering between alarm/normal, it may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set DI port trigger duration, if DI port at alarm state and exceeds specified duration, then ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes.  DI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, tower water level is low!  DI Alarm Clear Customize SMS The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning, tower water level return to normal! Attention: All customize SMS content can not include a comma, the comma as a parameter separator that can not be used as a custom SMS content, we have to use other symbols instead of comma.  WI Zone Type Close Zone: Close this wireless zone. Normal Zone: Start detect after arm immediately. Delay Zone: Start detect after Arm for 5 minuates, it’s for user to walk out of arm area. Smart Zone: after first trigger within ٦٠ seconds, if trigger again, ACTM will alarm. It’s for PIR montion sensor, in case the wrong alarm. Emergency Zone: whether Arm or Disarmed state, if trigger, ACTM will alarm; that’s for connect to emergency button, smoke sensor etc. Home Zone: This zone can be turning off by Home button of remote controller; when user at home, he can use this function for disable some sensor inside home.  WI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, detect people come in! Notice: Here is set wireless sensor WI zone types and customize SMS content, for using a wireless sensor, you must first register wireless sensors, according the wireless sensor registration, please refer to the "Wireless parameter setting".  Wireless sensor online detect period The Default value is OFF detect function; all of Arian wireless sensor/detector products support online detection function, the sensor sends online informatoin to ACTM about every ٣ hours, ACTM recieve online information that means sensor is online; if ACTM didn't received sensor online information for long time that means sensor already disconnect, ACTM will occur sensor disconnect alarm. The detection time can be set to ٨, ١٦, ٢٤ to ٩٦ hours, in order to avoid false alarms, we can choose the appropriate online detection period or OFF detection function.  AI Alarm Status This is AI port Upper&Lower voltage value, ٣٣٠ is ٣.٣V, For example: ١٠٠~٢١٠, when AI port voltage Lower than ١V, lower limit alarm happen; when higher than ٢.١V, Upper limit alarm. Value is 0~0 is disable AI port alarm. ٣٩
  • 40. GPRS/SMS ACTM User manual Notice: To prevent fluctuations in the value of AI interfaces to occur repeated alarm, when the AI interface value beyond the scope of the directive over the value of +10, ACTM will occur alarm, when the AI interface value back to the normal range -10, ACTM will occur alarm clear. This value can be set through”AI Port alarm Accuracy”. For example: set value as 100~210, so when the AI port value to be 90 or 220, ACTM will occur alarm, when the temperature return to 110 or 200, ACTM will occur alarm clear.  AI trigger duration Unit: ١٠٠ms, default value is 1, so the duration is 1٠٠ms. When AI port achieves alarm value, and keeps after specified duration, occur alarm. According to part of senors (such as voltage sensors, current sensors), the value may be hovering between alarm/normal, it may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set AI port trigger duration, if AI port at alarm state and exceeds specified duration, then ACTM will occur alarm. For example: the trigger duration set to ٣٠٠٠, so that's ٥ minutes.  AI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, water pressure exceeds the limit!  AI Alarm Clear Customize SMS The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning, water pressure return to normal!  AI Port alarm Accuracy The current value is greater than or lower than the set alarm value and more than the accuracy value, alarm hapeen.  TE Temperature Alarm Status This value is the temperature of the upper and lower limits, the units is ℃. For example: -5~28, when the temperature is lower than -5℃ or higher than 28℃, the alarm will occur; When the temperature returned to normal, the alarm clear will occur. 0~0 is disable TE port alarm. Notice: To prevent fluctuations in the value of TE temperature to occur repeated alarm, when the temperature value beyond the scope of the directive over the value of +1, ACTM will occur alarm, when the AI interface value back to the normal range -1, ACTM will occur alarm clear. For example: set value as -5~28, so when the temperature to be -6 or 29, ACTM will occur alarm, when the temperature return to -4 or 27, ACTM will occur alarm clear.  TE trigger duration Unit: ١s, default value is 1, so the duration is 1 second. When TE port temperature achieves alarm value, and keeps after specified duration, ACTM will occur alarm. According to temperature value may be hovering between alarm/normal, it may occur repeat alarm/alarm clear information, disturb user to determine. ACTM can set TE port trigger duration, if TE port at alarm state and exceeds specified duration, then ACTM will occur alarm. For example: the trigger duration set to ٣٠٠, so that's ٥ minutes.  TE Temperature Alarm Customize SMS The string length is not longer than 40, when the alarm occurs; send this alarm message content to the service number. For example: Warning temperature is too low!  TE Temperature Alarm Clear Customize SMS ٤٠
  • 41. GPRS/SMS ACTM User manual The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning clear, temperature return to normal! Attention: ACTM provides two kinds of temperature, TE1 is external digital temperature interface, it connects to extend temperature sensor, high accuracy. TE2 is embedded NTC temperature sensor, it’s for test environment and ACTM device temperature.  DO Output Control DO output, When DO output mode as High or Low level mode, choose high or low level the default is low level; the DO port output voltage is same as Vin PIN voltage.; When the DO output mode as programming mode, choose the high level to trigger the implementation of the programmatic output, after the implementation returns an unavailable level.  DO Output Mode ACTM DO port support 2 mode, High or Low Level Mode,output as High or Low Level simply; Program Modem,output as programming level  DO Output Program Example: 1,1,2,3,2,00:00:00; 1 is Port;1 is avaiable level,high or low; 2 is available level time period (Second); ٣ is unavailable level time period (Second); ٢ is cycle times; ٠٠:٠٠:٠٠ not implement as daily Notice: ACTM DO (digital output) port supports programmable output, according to the requirement of user site, the level of output level, switching time, times would be programmable. Please contact Arian technical engineer for instruction detail.  DO output link alarm When alarm trigger, link to DO output.  DO Output Link Program DO output the alarm link trigger port, type in the port name DI,TE,AI,WI (DI behalf of all DI port, DI١ specifically DI١ port only)  DO Smart Link For example: ٢,٦٠; ٢ times the specified port alarm within ٦٠ seconds, DO trigger output  Power Status Detect Detect external power status, if the external power disconnect, ACTM will send alarm SMS to service number. The default is ON.  Alarm Clear Message Set as ON, if detect port alarm clear, ACTM will send alarm clear message. F. Wireless Parameter Setting The parameter is for register wireless sensor, click the left mouse button on "Wireless"; enter to the Wireless parameter setting, the picture shown as below: ٤١
  • 42. GPRS/SMS ACTM User manual Notice: All wireless sensors must be registered on use wireless zones of the ACTM, and then it can be used.  Wireless Zone Zone: WI١ to WI٨ zones, each zone can be registered ٥ wireless sensors. Registrater: wireless sensor registerion, after choose the zone, click "Register", ACTM into the registration status, the information bar will prompt: Registratring ..., you need to take the wireless sensor to send an alarm signal (through Tamper button or alarm), when ACTM received this signal, you will heard "TA", it means sensor register successful. Cancel: click "Cancel" to cancel the current registration. Delete: select zone, then click "delete", it will delete the entire sensor on specified wireless zones. Delete All: click "Delete all", it will delete all wireless sensor from all zones.  Remoter Function: Arm, Disarm, Home button; total 3 remoter buttons, each button can be registerd for 5 remoter, it means each ACTM support max 5 remoter. Registrater: after choose the function button; click "Register", ACTM into the registration status, the information bar will prompt: Registratring ..., you need to push the button the remoter, and you will hear "TA" from ACTM, it means register successful. Cancel: click "Cancel" to cancel the current registration. Delete: select function button, then click "delete", it will delete the entire funmciton button of all remoter. Delete All: click "Delete all", it will delete all remoter on the all function buttons. Notice: Wireless sensor support tamper switch, low battery, link disconnect alarm, when ACTM disconnect link with sensors more than ١٦ hours, the disconnect sensor alarm will happen. ٤٢
  • 43. GPRS/SMS ACTM User manual After click the "Register" button, ACTM must receive the sensor signal within ٣ minutes; otherwise, ACTM will exit from register status. G. LED Screen Parameter Setting At the SMS Mode, ACTM can connect an LED Screen, the parameter is for LED Screen setting, , click the left mouse button on "LED Para."; enter to the LED parameter setting, the picture shown as below:  LED Screen At SMS mode, whether turn ON the LED screen function, when an alarm is occured, ACTM will send the alarm customize SMS content to the LED screen. if ACTM didn't connect with LED screen, turn OFFthis function. Attention: At GPRS communication mode, this option should be turned off. Data center platform will control the LED display via GPRS directly, it don't need ACTM to control. ٤٣  Window Number Send alarm information to the specified window number of LED screen  Display Time Alarm information display time period, ٠ to ٦٥٥٣٥ seconds, value ٠ is always show  Effects coding Alarm information display effects coding  Alignment Alarm information display Alignment  Display Speed Alarm information display speed, from ٠ to ١٠٠, the smaller the value are more faster  Stay time Alarm information display stay time  Font color
  • 44. GPRS/SMS ACTM User manual Alarm information display font color  Font Size Alarm information display font size H. Run Setting The parameter is for ACTM run setting, click the left mouse button on "Run Setting"; enter to the Run parameter setting, the picture shown as below:  ACTM ID Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be location name, owner name, cell phone number etc. we recommend to be SIM card number, and record the ID. The valuable range is 1~32 bytes.  Display Debug Info Debug information is use for engineer solve the problem, usually, it should be OFF. Attention: If turn on the debug information, the configuring software may predictable behavior during read/write ACTM parameters, then we should turn off debug information, and re-connect ACTM.  Enable Camera ACTM supports remote image capture function, connected through the RS٢٣٢ interface with the camera, when ACTM connects with camera; you need to turn this option ON.  ACTM Communication Mode ACTM support 5 mode to communication with center: TCP mode, ACTM communication with data center via GPRS, and establish TCP connection with data center. UDP mode, ACTM communication with data center via GPRS, and establish UDP connection with data center. SMS mode, ACTM sends the alarm information via SMS to the service center number. ٤٤
  • 45. GPRS/SMS ACTM User manual TCP + SMS mode, ACTM communicate with data center via GPRS , and establish TCP connection with data centers; but also support SMS functions, when alarm generated, ACTM will send alarm information through GPRS and SMS at same time. At the applicaiton, GPRS for data center, SMS end user to receive alarm at real time. UDP + SMS, ACTM communicate with data center via GPRS , and establish UDP connection with data centers; but also support SMS functions, when alarm generated, ACTM will send alarm information through GPRS and SMS at same time. At the applicaiton, GPRS for data center, SMS end user to receive alarm at real time.  Config Password Using ACTM Configuration software to set up ACTM, it need password. Please enter new password. The default value is 000000。 Attention: Please do not change the configuration password, if the password is incorrect, you will not able to set ACTM through configuration software. If you forget password, you can enter to the serial window, enter the command "at + ACTMdefault" to restore the default parameter, the password will restore the initial value of ٠٠٠٠٠٠.  Buzzer ON/OFF ACTM embedded buzzer  Defence Status Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM only monitor I/O status, but do not send alarm SMS. The default is not defence. Notice: From turn ON Defence, ACTM will enter defence status after ١٠ seconds. ACTM supports alias name to SMS to ARM/DISARM, the user just simply type in arm or disarm by the service center number. The command "at+defence=١" alias name is "arm"; the command "at+defense=٠" alias name is "disarm".  Timing Arm Executive ARM at the specified time daily.  Timing Arm Executive disarm at the specified time daily.  Password Disarm or Arm Any mobile phone can send SMS+password to remote disarm/arm, it can be set to maximum of ١٠ password, separated by commas. The default password is *, it means none. For example: send SMS”at+defence=1,123456” the 123456 is password, 1 means arm, 0 means disarm. Notice: This function is use for remote arm/disarm, if there is people who wanna enter to the area, he can send password to arm/disarm. After SMS command send successful, ACTM will return an sucssful SMS, and send copy to the administrator phone.  RFID/Alarm Resend Times For data center to receive all the alarm, ACTM can set resend alarm times, value is 0-65535. GPRS mode: ACTM resend alarm packet times if didn't receive center alarm ACK packet; SMS mode: ACTM resend alarm SMS times if didn't receive cellphone alarm ACK SMS. ٤٥
  • 46. GPRS/SMS ACTM User manual Notice: Set value as non ٠, the functional will effect. At the SMS mode, service number received alarm SMS should reply ACK SMS to the ACTM, otherwise ACTM will resend alarm SMS. There is a serial number for each alarm SMS, service number should reply ACK SMS as format: ACK - serial number, for example: ACK -١٢, service number reply ACTM that receives the serial number ١٢ alarm SMS.  RFID/Alarm Resend Interval ٠-٦٥٥٣٥ Seconds, ACTM resend alarm data packet interval if do not receive alarm ACK (Include GPRS and SMS)  Continue Alarm Interval ٠-٦٥٥٣٥ Seconds, When more than one alarm occurs, the time interval between continue alarm I. System Parameter ACTM system information, the option is only for query, it cannot be modify; click the left mouse button on "System"; enter to the system information, the picture shown as below: ٤٦  Manufacturer Name The default is Arian Ertebat Caspian Co. The Parameter is only for view.  Product Model The default value is ET٨٠٠٠ GPRS/SMS ACTM,The Parameter is only for view.  Software Version ACTM software version, The Parameter is only for view.  Hardware Version ACTM hardware version, The Parameter is only for view.  Config Tool Version Config Tool Version, The Parameter is only for view.  Product SN ACTM product SN, the Parameter is only for view.  Product Number
  • 47. GPRS/SMS ACTM User manual ٤٧ ACTM product number, The Parameter is only for view.  IMEI Number ACTM IMEI Number, The Parameter is only for view.
  • 48. GPRS/SMS ACTM User manual ٤٨ Chapter 5 Typical Application This chapter describes in detail about ACTM typical application, by reading this chapter, the reader should be able to know choose suitable mode and set up ACTM. ١. SMS alarm application ٢. ACTM management platform application ٣. Transparent data transmission application ٥.١ SMS alarm application For a small number of sites, SMS time delay is acceptable, simple operation, easy maintenance project, we recommended using SMS mode, the user can remote monitoring system through mobile phone, when an alarm occurred, ACTM will send SMS to mobile phone, according to alarm, the user can send commands directly control ACTM. The detailed SMS command instructions please check the attachment. Set ACTM to SMS mode that needs to configure the following parameters:  Service Number For example: +٨٦١٣٨١٢٣٤٥٦٧٨ or ٨٦١٣٨١٢٣٤٥٦٧٨, please pay attention to add country code on the front, the number is for receive alarm SMS from ACTM, and remote control ACTM through SMS. You can set up max four service center number. and must be set to at least one central number to take SMS mode effect.  SMS Alarm Content For easy to read the alarm SMS, user can per-set the alarm SMS to the ACTM, when the alarm happen, ACTM will send the pre-set SMS to service number. Customize SMS mode, ACTM will send alarm SMS according pre-set alarm content; Arian protocol, ACTM will send alarm SMS according Arian protocol Pre-set customize SMS is more easy to read alarm information, we recommend using a customize SMS.  DI Alarm Status Low level, when port is low level, alarm happen; High level, when port is high level, alarm happen ;Status Change, when the port status change, alarm happen. The default is Disable alarm.
  • 49. GPRS/SMS ACTM User manual According to the actual situation, set the I/O port alarm status, we only make example on DI port, please set AI and TE port alarm status at same.  DI Alarm Customize SMS The string length is not longer than ٤٠, when the alarm occurs; send this alarm message content to the service number. For example: Warning, tower water level is low!  DI Alarm Clear Customize SMS The string length is not longer than ٤٠, when the alarm clear occurs; send this alarm clear message content to the service number. For example: Warning, tower water level return to normal!  ACTM ID Giving a name to ACTM, it’s for user to identify the SMS from which ACTM, it would be location name, owner name, cell phone number etc. we recommend to be SIM card number, and record the ID. The valuable range is 1~32 bytes.  ACTM Communication Mode ACTM communication with center mode; SMS mode, ACTM using SMS to communication with service number; TCP and UDP mode, ACTM using GPRS to communication with data service center. It must be set as SMS mode.  Defence Status Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM only monitor I/O status, but do not send alarm SMS. The default is not defence. It must be set as Defence status, so ACTM can monitor I/O port, and send alarm SMS. Attention: ACTM has a clock function, and using SMS to synchronization time, power up on ACTM for the first time, please send "Timecal" SMS to ACTM through mobile phone, then ACTM will reply "ACTM OK". Just set up once, ACTM will always using the clock running. For the command detail, please check Chapter ٧. Notice: After setting these parameters, we need to restart ACTM to take function effect. According the sensor installation, please check Chapter ٣ Installation. ٥.٢ ACTM management platform application For more sites, complicated network, real-time is necessary, alarm history project, we recommend using ACTM management platform. ACTM management platform through the SQL database to save all alarm history, it's easy to use, and able to export excel report; through GOOGLE map to showing the location of all site, when an alarm occurs, the alarm immediately show red alarm logo on the map; with B/S structure, the user can management all device at anywhere where just open browser; multi-level permissions can be set to view and manage permissions, for normal users can only able to view, cannot operation. Below picture shown ACTM management platform software, more information please check Arian website. ٤٩
  • 50. GPRS/SMS ACTM User manual Set ACTM to connect ACTM management platform mode that needs to configure the following parameters:  APN Name (APN) Follow the prompts to enter information into the access point name (access point name cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" button on the navigation bar ", the message bar will show "parameters set successfully". According to different operator, enter to the correct APN name.  Main IP address x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center through domain name.  Main Domain Name Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center. Notice: The main IP address and main domain name must be input, if else, ACTM will not able to communication with ACTM platform.  Main Port ١-٦٥٥٣٥, Main data center IP port  Work mode GPRS transmission work mode, IO protocol mode will send&receive data through Arian protocol, and it use for connect ACTM management platform; transparent mode, using the ٥٠
  • 51. GPRS/SMS ACTM User manual transparent data channel, and sends heartbeat packets, it’s for connect to other platform or data center. It must be set as IO protocol mode, so ACTM will use Arian communication protocol to connect with ACTM platform.  DI Alarm Status Low level, when port is low level, alarm happen; High level, when port is high level, alarm happen ;Status Change, when the port status change, alarm happen. The default is Disable alarm. According to the actual situation, set the I/O port alarm status, we only make example on DI port, please set AI and TE port alarm status at same.  ACTM Communication Mode ACTM communication with center mode; SMS mode, ACTM using SMS to communication with service number; TCP and UDP mode, ACTM using GPRS to communication with data service center. It must be set as TCP or UDP mode.  Defence Status Defence, ACTM will monitor I/O status, and send alarm SMS; Not Defence Status, ACTM only monitor I/O status, but do not send alarm SMS. The default is not defence. It must be set as Defence status, so ACTM can monitor I/O port, and send alarm information. Notice: After setting these parameters, we need to restart ACTM to take function effect. According the sensor installation, please check Chapter ٣ Installation. ٥.٣ Transparent data transmission application As RTU and PLC which provide RS٢٣٢ interface, ACTM provides RS٢٣٢ interface to connect with RTU and PLC, using transparent data channel that send RTU data to data center. Data center can use the RTU software or data center platform to receive ACTM+RTU data. Set ACTM to transparent data transmission mode that needs to configure the following  APN Name (APN) Follow the prompts to enter information into the access point name (access point name cannot be empty), enter the characters that not more than ٣٢ characters, and click Save" button on the navigation bar ", the message bar will show "parameters set successfully". According to different operator, enter to the correct APN name.  Band Serial port configuration, selectable baud rate is ٣٠٠-١١٥٢٠٠. Attention: ٥١
  • 52. GPRS/SMS ACTM User manual This band is same band with configuration software connect to ACTM, if you modify this band rate, simultaneously modify configuration band, then the configuration software able to connect the ACTM.  Main IP address x.x.x.x, Main data center IP address; if fill in 0.0.0.0, ACTM will connect data center through domain name.  Main Domain Name Main data center domain name, it will be enable when the main IP address is ٠.٠.٠.٠; ACTM will analysis domain name to be IP address, then using the IP address to connect data center. Notice: The main IP address and main domain name must be input, if else, ACTM will not able to communication with ACTM platform.  Main Port ١-٦٥٥٣٥, Main data center IP port  Work mode GPRS transmission work mode, IO protocol mode will send&receive data through Arian protocol, and it use for connect ACTM management platform; transparent mode, using the transparent data channel, and sends heartbeat packets, it’s for connect to other platform or data center. It should be set as transparent mode usually, ACTM will use transparent channel to connect with data center. If the data center use Arian ACTM management platform while using the RTU, then select IO protocol mode.  ACTM Communication Mode ACTM communication with center mode; SMS mode, ACTM using SMS to communication with service number; TCP and UDP mode, ACTM using GPRS to communication with data service center. It must be set as TCP or UDP mode. Notice: After setting these parameters, we need to restart ACTM to take function effect. According the sensor installation, please check Chapter ٣ Installation. ACTM provides storage and forwarding the command functions of the MODBUS protocol, users can pre-save the common command to ACTM, and ACTM will send the command PLC/RTU via RS٢٣٢/٤٨٥ port by the specified time interval automatically. Please contanct Arian technical engineer for instruction detail. ٥٢
  • 53. GPRS/SMS ACTM User manual ٥٣ Chapter 6 Operation This chapter describes in detail about ACTM operation and troubles shooting, by reading this chapter, the reader should be able to solve general ACTM problem. ١. Panel Indications ٢. ACTM operation Guidance ٣. Trouble Shooting ٦.١ Panel Indications There are four LEDs at ACTM-9220 ACTM front panel; it indicates the ACTM network, operation and alarm status. The below form is the LED indicators description: Status Sub-Status PWR NET DATA ALM Initial state Initialing Lights Up Lights Down Lights Up Check SIM Lights Up 1 Second Flash Lights Down GPRS Dial up Lights Up Lights Down 0.3 Second Flash GPRS registing Lights Up 0.3 Second Flash Lights Down Connecting to Data center Lights Up 0.3 Second Flash 0.3 Second Flash Work state GPRS Standby (Sleep) Lights Up Lights Down 5 Second Flash GPRS/SMS work status Lights Up According the Signal strength to flash Flash on data transmission Light Up at battery power, flash at alarm happen Notice: After ACTM work well, the NET indicator will blink according to the signal strength, ACTM will query signal strength per minute. CSQ Signal strength in the ٠١-١٢, very fast flash; CSQ signal strength in the ٠٣-١٨, fast blinking; CSQ signal strength in the ١٩-٣١, slow blinking; After ACTM work well, PWR indicator will light up, DATA and NET indicator will light up for 2 seconds and light down for 2 seconds. ALM indicator and buzzer that there is alarm occur, it will buzz or blink. When ACTM switch to battery power, the ALM LED will light UP.
  • 54. GPRS/SMS ACTM User manual ٥٤ ٦.٢ ACTM operation Guidance ACTM is an intelligent wireless data terminal; after installation and setting, just connect sensor and power, then it will work well. ACTM should be installed at place with good radio signal receiving. For the cabinet and basement environment, we recommend to extend the antenna. Warning: For outdoor use, lightning should be considered. We propose to install an arrester between antenna and the ANT interface. Contact Arian technical support department for details. No routine maintenance is required for ACTM operation. At embedded application environment, the data service center will check ACTM operation information. ٦.٣ Trouble Shooting Problem ١: All LEDs do not light up. Check all cables that are connected to the ACTM. Check the power supply adapter output voltage. If the power is correctly connected and there is no LED that light up, the ACTM may be failed. Contact to Arian or reseller for repairing. Problem 2: Instability after working long time. Please check whether the device is overheating, if overheated, put device into place in order to facilitate ventilation and cooling equipment. Problem 3: Using the configuration software to connect ACTM, but always unsuccessful. It needs to select the correct serial port and rate to connect ACTM, the default rate is ١١٥٢٠٠. Attention: if use of USB-RS٢٣٢ converter cable to connect ACTM, please use Arian configuration cable. If use other brand of USB converter cable, please pay attention to buy high-quality cable, there is many bad-quality cable on the market, it may occur many problem to connect. In addition, PC's serial port is very easy to down, sometimes, you need to restart PC, and then try to connect. Problem 4: I have already connected the sensor, set the port alarm status, but when an alarm is occurred, ACTM did not send the alarm information. Please check to set ACTM defence to be "defence" status, after set to "defence" status that wait for ١٠ seconds, ACTM will start monitor I/O port status. Problem 5: I'm using the configuration software, and already connect to ACTM successful, but when I query/save parameter, it show query/save failed, so I cannot config parameter. ACTM in without cards or GPRS connection mode, it may automatically restart after connect ACTM unsuccessful, when you open the configuration software for while, it show errors, so ACTM may be restarted, then just click "connect" button, configuration software
  • 55. GPRS/SMS ACTM User manual will try to connect ACTM again. Now, try to query/save parameter that will be successful. We suggest insert SIM first then set up ACTM. Problem 6: I'm using the configuration software, but there is many parameters are illegal value. The reason that's open the debugging information, ACTM debug information is large amount of data; it may affect configuration software to read/write parameter from ACTM sometimes. so please turn OFF the ACTM debug information then using the configuration software. Problem 7: ACTM shows ٤ lights flashing simultaneously, buzzer alarms fast flash, data cannot communication. This problem is ACTM internal battery will be no power soon. Please check the external power supply, and the power cord, you can check it on the ١٢PIN terminal. Problem 8: I connected ١٢V relay to ACTM DO port, set DO port output as high lever through configuration software, but the relay didn't action. DO port supply voltage is same Vin pin voltage, if using ١٢V relay, make sure the Vin pin voltage is the same as ١٢V. also, check the external power supply, if external power lose, ACTM will use internal battery, then DO only has ٣.٧V voltage, so relay will no action also. Problem 9: After turn ON ACTM power, it display PWR, DATA, NET, ALM all are lights up, and ACTM does not work. ٤ lights up means the ACTM is in the software upgrade status check the upgrade firmware button on the configuration cable, just press the button, and restart the ACTM, ACTM will return to normal mode. Problem 10: ACTM buzzer sometimes occur a short "TA"sound. This is normal, when ACTM is no signal or cannot connect to data center for many times, it will automatically restart, the buzzer will occur short "TA" sound. Problem 11: Set up ACTM service center number, but the number does not receive alarm SMS. Check the service center number is that fill in correct format, the numbers must add the country code + or ٠٠ in the front, if doesn't fill in the country code or the + and ٠٠ doesn’t in the front, ACTM may not able to send out SMS. ٥٥
  • 56. GPRS/SMS ACTM User manual ٥٦ Chapter 7 Attachment SMS Command This chapter describes in detail about SMS command detail, by reading this chapter, the reader should be able to how to remote control ACTM by SMS. ١. Introduction ٢. Command format ٣. Command list ٤. Command detail ٥. Alarm information format ٧.١ Introduction ACTM SMS command list defines a format of SMS communication format, its use for ACTM and the cell phone communication each other. Users should follow this document to the remote control ACTM by SMS. This command list applies to all ACTM products. ٧.٢ Command format A. ACTM commands were signed by the command code, Parameter separator, parameters, three major elements; multiple parameters can be composed of the parameter list. Command total length should not exceed ٥٠ characters, if the command is too long, it can be sent by multiple divided SMS. Command Parameter separator Parameter, Parameter list Command “=” ( Separator between command and parameters) “,”(Separator between Multiple parameters) “?”(Enquiry symbol) Parameter Command=param1,param2,param3…….. Command? Attention: We must be set ACTM service number to be remote cell phone number, other phone numbers send commands to the ACTM, ACTM will do not implement.
  • 57. GPRS/SMS ACTM User manual ٥٧ ٧.٣ Command list Timecal ACK At+ACTMpsw At+ACTMrst At+transtype At+ACTMid At+almlvset At+almlvread At+almbat At+defence At+outctrl At+inctrl At+almclr At+almpoint At+almsect At+servnum At+servalm At+almparam At+almflag At+mservip At+bservip At+mservname At+bservname At+sleepmode At+conntry At+miscintv At+accinfo ٧.٤ Command detail Command Timecal Function SMS Clock synchronization command Parameter None MEMO This command only through SMS, it cannot implement by console port. Example: Timecal Returns: ACTM TIME CALIBRATION OK,2011/01/18-09:54:47 Command At+ACTMrst Function ACTM reboot Parameter None MEMO There is no response SMS from ACTM, after send command, ACTM will restart immediately. Example: At+ACTMrst Returns: Command At+transtype Function ACTM with data center communication way Parameter ? Query the command current value, example: At+transtype? 0 Using SMS for communication with service center cell phone 1 Using TCP for communication with data center 2 Using UDP for communication with data center 3 Using TCP+SMS for communication with data center 2 Using UDP+SMS for communication with data center MEMO The default is 0,SMS mode Example: At+transtype=1 Returns: transtype = ١ ACTM OK Command At+ACTMid
  • 58. GPRS/SMS ACTM User manual Function ACTM ID (it cannot exceed 32 letters), this ID is ACTM identify number, ٥٨ the service center to identify different SMS by this ID. Parameter ? Query current command value, example: At+ACTMid? ID Change ACTM ID to current value MEMO Example: At+ACTMid=SHENZHEN At+ACTMid? Returns: ACTM ID:SHENZHEN ACTM OK Command At+almlvset Function Set I/O port alarm level Parameter Para1, para2, para3 Para1 port name, it is DI,AI,TE Para2 port number, it is 1,2,3,4,5,6,7 Para3 port value: DI port: value 0, disable alarm value 1, low level alarm value 2, high level alarm value 3, the level status change alarm AI port: Min*Max, when AI port current value exceed range above +10, ACTM will occurred alarm, when AI port return to normal range -10, ACTM will occurred alarm clear. TE port: Min*Max, when TE port current value exceed range above +1, ACTM will occurred alarm, when TE port return to normal range -1, ACTM will occurred alarm clear. MEMO Example: Set DI3 port high level alarm command is as below: At+almlvset=DI,3,2 Set AI1 port minimum value to 0, Maximum value to 100: At+almlvset=AI,1,0*100 Set TE1 port minimum value to -20, Maximum value to 70: At+almlvset=TE,1,-20*70 Returns: DI:٠x٠٠٠٠٠٠٢٠ ACTM OK Command At+almlvread Function Query IO port alarm value Parameter Para1, para2 Para1 port name, it is DI, AI, TE, if there is no para2, the command will query all of port name value. Para2 port number, it is 1,2,3,4,5,6,7 MEMO Example: Query DI3 port alarm value: At+almlvread=DI,3 Query all of AI port alarm value: At+almlvread=AI Query TE1 port alarm value: At+almlvread=TE,1
  • 59. GPRS/SMS ACTM User manual ٥٩ Returns: DI(٠٣)LV=٢ ACTM OK Command At+inctrl Function Query current IO port status Parameter Para1, para2 Para1 port name, it is DI, AI, TE, ALL; ALL will query all of Port value. Para2 port number, it is 1,2,3,4,5,6,7 MEMO Example: Query DI3 port current value: At+inctrl=DI,3 Query TE1 port current value: At+inctrl=TE,1 Query ALL port current value: At+inctrl=all Returns: ٠,0,0,0,0,0,0,0 0,364,340,424 0,36 ACTM OK MEMO:the first line of returns is DI port current value, the second line of returns is AI port current value, the thired line of returns is TE port current value. Command At+outctrl Function Control DO port output high level or low level; High level: DC12V Low level: 0V Parameter ? Query DO port current output status, example: At+outctrl? Para1, para2 Para1 DO port number, it is 1,2,3,4 Para2 port value, 0 is low level, 1 is high level. MEMO Note: DO ports with memory function, if there is power-off, restart, ACTM can automatically restore the previous settings of the state. But there is always low level during ACTM boot. Notice: If set At+almlink, the At+outctrl command will be unfunction, the DO port will only control by port alarm. Example: Set DO1 port output high level At+outctrl=1,1 Query DO port current output status At+outctrl? Returns: DO:١,١,١,١ ACTM OK Command At+almbat Function Detect external power status Parameter ? Query command current value, example: At+almbat? 0 ACTM do not detect external power status, not occurred alarm. 1 ACTM detects external power status, if there is change, ACTM will occur alarm. MEMO The default value is 1. Example:
  • 60. GPRS/SMS ACTM User manual ٦٠ Set detect external power status: At+almbat=1 Returns: power status check enable ACTM OK Command At+defence Function Defence or not defence Parameter ? Query current command value, example: At+defence? ٠ not defence, all IO ports are not in the surveillance state, that does not occurred alarm information ١ defence all IO port are in the surveillance state. MEMO The default value is 1. Alias name "at+defence=١" alias name is "arm"; "at+defense=٠" alias name is "disarm". Example: Set ACTM defence At+defence=1 Returns: DEFENCE ACTM OK Command At+almclr Function Alarm clear message Parameter ? Query command current value, example: At+almclr? ٠ do not send alarm clear message ١ send alarm clear message MEMO The default value is 1 Example: Set ACTM send alarm clear message At+almclr=1 Returns: ON ACTM OK Command At+almpoint Function Set ACTM report IO port status as appoint time everyday Parameter ? Query command current value, example: At+almpoint? Para1,Para2 Para1 0 disable function, 1 enable function Para2 time format: hh:mm:ss MEMO Example: Set everyday 12:30:15 report current IO port status At+almpoint=1,١2:30:15 Returns: auto send time point enable ACTM OK Command At+almsect Function Set ACTM auto report IO port status as specify interval Parameter ? Query command current value, example: At+almsect? Para1,Para2
  • 61. GPRS/SMS ACTM User manual ٦١ Para1 0 disable function, 1 enable function Para2 Interval, the unit is second MEMO Example: Set auto report interval as 8000 seconds At+almsect=1,8000 Returns: auto send interval enable auto send interval:٨٠٠٠ ACTM OK Command At+servnum Function Set ACTM service center number Parameter ? Query command current value, example: At+servnum? It will display 4 service center number Para1,Para2 Para1 Service center number series number, it is 0,1,2,3 Para1 Service center number, any numbers. MEMO Service center number is data center modem SIM card number or user cell phone number; ACTM will send alarm SMS to this number, the max number is 4. Example: Send the second service center number as 13812345678 At+servnum=1,13812345678 Returns: to(١) :١٣٨١٢٣٤٥٦٧٨ ACTM OK Command At+servalm Function Set service center number receive alarm message Parameter ? Query current value, example: At+servnum? Para1,Para2,Para3,Para4 Para1 The first service center number receive alarm SMS, 0 is not receive, 1 is receive Para2 The second service center number receive alarm SMS, 0 is not receive, 1 is receive Para3 The third service center number receive alarm SMS, 0 is not receive, 1 is receive Para4 The fourth service center number receive alarm SMS, 0 is not receive, 1 is receive MEMO If set service center do not receive alarm SMS, so this number will only remote configuration via SMS. Example: Set only the third service center number receive alarm SMS At+servalm=0,0,1,0 Returns: ٠,٠,١,٠ ACTM OK Command At+almparam Function Set ACTM SMS alarm resend Parameter ? Query current command value, example: At+almparam? Para1,Para2,Para3 Para1 Set center number do not response ACK, the resend SMS
  • 62. GPRS/SMS ACTM User manual retransmissions, if set as 0, disable alarm SMS receipt function, so alarm SMS will only send to center number once. Para2 Set alarm SMS resend wait interval, the unit is second Para3 Set continue alarm SMS interval, the unit is second ٦٢ MEMO Example: Set retransmissions to be 3, resend SMS interval to be 300 seconds At+almparam=3,300,0 Returns: ٣,٣٠٠,٠ ACTM OK Command ACK Function SMS receipt, if enable ACK function, center service number should reply ACK SMS when receive alarm SMS. Parameter ٠٠1 ~ ٩٩٩ alarm SMS series number, all occurred alarm SMS has an series number, Data center reply ACK with series number to inform ACTM that receive which alarm SMS already. MEMO This command is only available through SMS. Example: Data center send SMS receipt, alarm SMS series number is 001 ACK -٠٠١ Data center send SMS receipt, alarm SMS series number is 2 ACK -٢ Command At+almflag Function Set GSM dial up center number and Buzz Parameter ? Query command current value, example: At+almflag? Para1,Para2 Para1 before send SMS alarm, ACTM will dial up center number to inform alarm occurred. 0 disable function, 1 enable function. Para2 Buzz, ٠ turn off buzz, 1 turn on buzz MEMO GSM dial function default value is 0, Buzz default value is 0 Example: Set alarm to ring service number, and turn on buzz At+almflag =١,1 Returns: wtt[٠] = ١ wtt[١] = ١ wtt[٠] = ١ wtt[١] = ١ ACTM OK *Command At+mservip Function Set main data center IP address, port Parameter ? Query current command value, example: At+mservip? Para1,Para2 Para1 Data center IP address, if using domain name, here should be 0.0.0.0 Para2 Port number MEMO Example: Set main data center IP as 20.13.48.6, port as 5008 At+mservip=20.13.48.6,5008 Returns:
  • 63. GPRS/SMS ACTM User manual ٦٣ ip = ٢٠.١٣.٤٨.٦ port = ٥٠٠٨ ACTM OK *Command At+bservip Function Set backup data center IP address, port Parameter ? Query current command value, example:At+bservip? Para1,Para2 Para1 Data center IP address, if using domain name, here should be 0.0.0.0 Para2 Port number MEMO Example: Set backup data center IP as 10.23.48.6, port as 5007 At+bservip=10.23.48.6,5007 Returns: ip = ١٠.٢٣.٤٨.٦ port = ٥٠٠٧ ACTM OK *Command At+mservname Function Set main domain name address Parameter ? Query current command value, example:At+mservname? Para1 Domain name, any character MEMO Example: Set main domain name address as ACTM.Ariancn.com At+mservname=ACTM.Ariancn.com Returns: server name = ACTM.Ariancn.com ACTM OK *Command At+bservname Function Set backup domain name address Parameter ? Query current command value, example:At+bservname? Para1 Domain name, any character MEMO Example: Set Backup domain name address as ACTM.Ariancn.com At+bservname =ACTM.Ariancn.com Returns: server name = ACTM.Ariancn.com ACTM OK *Command At+sleepmode Function ACTM sleep function Parameter ? Query current command value, example:At+sleepmode? Para1,Para2 Para1 whether enable sleep function Para2 the wait time for enter sleep status, the units is second. MEMO Detected the specified time that without data transmission RS٢٣٢ interface, and no IO alarm occurred, ACTM will go to sleep. The default is ٠, disable the sleep function Example: