S&A CWFL-1500 dual temperature industrial water chillers specially designed for cooling 1500W fiber lasers has multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm.
Water chiller units cwfl 1500 with environmental refrigerant for fiber lasers cwfl-1500
1. www.teyuchiller.com
S&A CWFL-1500 dual temperature industrial water chillers specially designed for
cooling 1500W fiber lasers has multiple alarm functions: compressor time-delay
protection, compressor overcurrent protection, water flow alarm and over high / low
temperature alarm.
The CWFL series water chillers are so multi-functional that the laser device and the QBH
connector/optics can be cooled by the low temperature control system and the high temperature
control system respectively at the same time, which can greatly reduce the generation of the
condensed water and save cost & space.
1500W fiber laser water chiller units features
1. 5100W cooling capacity; optional environmental refrigerant;
2. ±0.5℃ precisely temperature control;
3. The intelligent temperature controller has 2 control modes, applicable to different applied
occasions; with various setting and display functions;
4. Dual temperature to satisfy different needs of fiber laser device and the optics;
5. With Ion adsorption filtrating and test functions conform to fiber laser device operating
requirements;
6. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection,
water flow alarm and over high / low temperature alarm;
7. Multiple power specifications; CE approval; RoHS approval; REACH approval;
8. Optional heater and water filter.
THE WARRANTY IS 2 YEARS AND THE PRODUCT IS UNDERWRITTEN BY INSURANCE
COMPANY.
3. www.teyuchiller.com
Independent production of sheet metal, evaporator and condenser
Adopt IPG fiber laser for welding and cutting sheet metal.
High precision temperature control system with dual temperature control function
Temperature control accuracy can reach ±0.5℃. High temp. for QBH connector/optics
and low temp. for laser device.
Multiple alarm protection
The laser will stop working once it receives alarm signal from the water chiller for
protection purpose.
Equipped with water pressure gauges ,drain outlet with valve and universal
wheels.
Water pressure gauges help monitor the discharge pressure of water pump while
universal wheels facilitate the moving of the chiller.
5. www.teyuchiller.com
Dual inlet and dual outlet connector equipped.
Chiller inlet connects to laser outlet connector. Chiller outlet connects to laser inlet
connector.
Level gauge equipped
6. www.teyuchiller.com
Cooling fan of famous brand installed.
Adopt SAN JU cooling fan with high quality and low failure rate.
Customized dust gauze available and easy to take apart
7. www.teyuchiller.com
TEMPERATURE CONTROLLER PANEL DESCRIPTION
S&A industrial water chillers are popular for its 2 temperature control modes as constant
temperature and intelligent temperature control.Generally speaking, the defaulted setting for the
temperature controller is intelligent temperature control mode. Under intelligent temperature control
mode, the water temperature will adjust itself according to the ambient temperature. However,
under constant temperature control mode, users can adjust the water temperature manually.
Suggestion:
Intelligent temperature control mode for QBH connector/optics
Constant temperature control mode for laser device
Temperature controller panel description:
8. www.teyuchiller.com
Alarm function
(1) Alarm Display:
When alarm occurs, the error code and the temperature will be alternately displayed.
(2) To suspend the alarm:
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm
display remains until the alarm condition is eliminated.
ALARM AND OUTPUT PORTS
In order to guarantee the equipment will not be effected while abnormal situation happens on the
chiller, CWFL-1500 series chillers possess alarm protection function.
1. Alarm output terminals and wiring diagram.
2. Alarm causes and working status table.
9. www.teyuchiller.com
Note: The flow alarm is connected to the normally open relay and normally closed relay contacts,
requiring operating current less than 5A, working voltage less than 300V.
CHILLER APPLICATION
10. www.teyuchiller.com
WAREHOUSE
18,000 square meters brand new industrial refrigeration system research center and production
base. Strictly execute ISO production management system, using mass modularized standard
produces, and standard parts rate up to 80% which are the source of quality stability.
Annual production capacity of 60,000 units, focus on large, medium and small power chiller
production and manufacture.
TEST SYSTEM
With excellent laboratory testing system, simulates actual working environment for chiller. Overall
performance testing before delivery: aging test and complete performance test must be executed
on each finished chiller.