High TBT (85°C) MED
Technology Development
Osman A. Hamed, Khalid Bamardouf, Abdulaziz S. Al-Jamhan, Faisal A. Abu Derman
Desalination Technologies Research Institute (DTRI)
Saline Water Conversion Corporation (SWCC)
Younggeun Lee*, Amr M. Ahmed, Byungsung Park, Seungwon Ihm
Doosan Water R&D Center Dammam, KSA
1
TABLE OF CONTENTS
INTRODUCTION
WATER BUSINESS IN DOOSAN
BUSINESS GROUPS
INTRODUCTION TO DOOSAN WATER
PREVIOUS STUDY IN KOREA
CONCLUDING REMARKS
JOINT DEMONSTRATION IN KSA
HT MED TECHNOLOGY DEVELOPMENT
2
DOOSAN HEAVY INDUSTRIES & CONSTRUCTION
CASTING & FORGING
POWER
WATER
EPC
Global Leader
in power
and water
Front Runner
in industrial
plants
At Doosan Heavy Industries & Construction, our vision is to be a global leader in power and water,
and we are committed to helping our clients meet tomorrow’s challenges and opportunities.
NUCLEAR
• Revenue: US$18.1 billion
• Employees: 8,200
(2014 figures / Locally hired employees excluded)
Boost
in global business
competencies
Renewable Energy
for our future
Doosan
IMGB
Doosan
Skoda Power
Doosan
Babcook
Doosan
Lentjes
Doosan
Power
System India
Doosan
VINA
Doosan
Hydro
Technology
Doosan
Enpure
DESALINATION TECHNOLOGIES
RO (REVERSE OSMOSIS)
World’s largest RO train with
application of 16-inch membranes
MED (MULTI-EFFECT
DISTILLATION)
High TBT MED-TVC
MSF (MULTI-STAGE FLASH)
Large-scale unit, one-module
fabrication, and hybrid solution
World’s Largest Multi-Effect
Distillation (MED) Distiller
Location : Yanbu, Saudi Arabia
Client : SWCC
Distiller Unit Capacity
: 15MIGD (68,190m³/day)
Configuration : 15 MIGD x 1 unit
Gain Output Ratio : 9.7
Delivery : 18 months
[Yanbu Ph.2 Exp. MED] KSA [Busan Gijang RO] Korea
[Escondida Water Supply] Chile
Largest Desalination Plant
in South America
Capacity : 47.5MIGD (215,935m³/day)
Pretreatment : Pressurized DMF
Configuration : 5.3MIGD x 9 trains
Feed water TDS : 39,300 mg/L
Product water TDS : < 700 mg/L
Client : Minera Escondida (BHP Billiton)
Currently delivering the project for the
world’s largest copper mining operation
World’s Largest Desalination Plant
with Hybrid Config. (MSF + RO)
Capacity : 228MIGD (1,036,488m³/day)
Location : Ras Al Khair, Saudi Arabia
Client : Saline Water Conversion
Corporation (SWCC)
Evaporator Unit Capacity
: 20MIGD (90,920m³/day)
Configuration : 20 MIGD x 8 units
Performance Ratio : 9.5
Dimensions(m) : W118.8 x L24.3 x H11.4
[Ras Al Khair Ph.1 Hybrid] KSA
3
OPERATION & MAINTENANCE
World’s Largest Desalination Plant
(Hybrid (MSF+RO))
Capacity : 228MIGD (1,036,488m³/day)
Pretreatment : DAF+DMF+Cartridge filters
TDS : 45,000 mg/L
O&M Period : 6 years (’13.12~’19.4)
Client : SWCC
Simultaneous service for both thermal
(MSF) and SWRO plants
* Information & Communication Technology
Korea’s First Large-scale
Desalination Plant
Capacity : 10MIGD (45,460m³/day)
Pretreatment : DABF+UF/DABF+DMF+C.F.
TDS : 34,500 mg/L
O&M Period : 20 years (’14.7~’34.6)
Client : Busan Metropolitan City
Service for the world’s largest capacity
RO train (8MIGD) with 16-inch membranes
[Shuwaikh RO] Kuwait [Ras Al Khair Ph.1] Saudi Arabia [Busan Gijang RO] Korea
O&M
Optimization
Know-how
Based on commissioning
experience with over 20 plants
Flexibility
Offered through a unified
channel (EPC + O&M)
Efficiency
Provided through
ICT* solutions
Kuwait’s First SWRO
Desalination Plant
Capacity : 30MIGD (136,380m³/day)
Pretreatment : DAF+UF
TDS : 45,000 mg/L
O&M Period : 3 years (’11.10~’14.10)
Client : Ministry of Electricity & Water
Challenging conditions including frequent
red tides events and high TDS
4
5
REFERENCES
MORE THAN 20 LARGE-SCALE DESALINATION PLANT REFERENCES IN MENA AREA
* 7 million ton/day
** 300 liter/person
Shoaiba Ph.4
Doha RO Ph.1
Escondida SWRO
Yanbu Ph.3
Marafiq MED
Yanbu MED
Ras Al Khair Ph.1
Jeddah RO Ph.3
Shuweihat S2
Shuwaikh RO
Shuaibah Ph.3 Exp.RO
Shuaibah Ph.3 IWPP
Sabiya Ph.3
Sabiya Ph. 1&2
Ras Laffan B
Sohar
Fujairah Hybrid
88
60
47.5
121
12
15
228
53
100
30
30
194
50
60
33
50
100
RO
RO
RO
MSF
MED
MED
MSF+RO
RO
MSF
RO
RO
MSF
MSF
MSF
MSF
MSF
MSF+RO
Project Name Capacity
(MIGD) Type
Construction Period
’05
’04 ’06 ’07 ’08 ’09 ’10 ’11 ’12 ’13
References & Records
KSA
Kuwait
Chile
KSA
KSA
KSA
KSA
KSA
UAE
Kuwait
KSA
KSA
Kuwait
Kuwait
Qatar
Oman
UAE
Country
Total of 33 Projects :1,626 MIGD*
For daily use by 24.7 million people**
’14 ’15
1 MIGD (Million Imperial Gallon per Day) = 4,546 m3/day water production
’16 ’17
6
TABLE OF CONTENTS
INTRODUCTION
WATER BUSINESS IN DOOSAN
BUSINESS GROUPS
INTRODUCTION TO DOOSAN WATER
PREVIOUS STUDY IN KOREA
CONCLUDING REMARKS
JOINT DEMONSTRATION IN KSA
HT MED TECHNOLOGY DEVELOPMENT
7
INTRO… Desalination Technology
[Reliability]
[Energy
Efficiency]
High
High
Low
Low
Current
Technologies
High Reliability &
Energy Efficiency
Future
Technologies
MSF
MED
RO
MD
FO
8
COMPARISON FOR SEAWATER CONDITION
1
2 3
4
5
TDS: less 35,000 ppm
Turbidity: less 2 NTU
Red Tide: Rare1
Singapore
4
Seawater condition in Gulf area is much worse
than any other region.
TDS: less 38,000 ppm
Turbidity:3~6 NTU
Red Tide: Rare1
Chile
5
TDS: less 41,000 ppm
Turbidity: less 2 NTU
Red Tide: None 1
Mediterranean
2
TDS: less 40,000 ppm
Turbidity: less 2 NTU
Red Tide: None
1
Spain
1
TDS: over 45,000 ppm
Turbidity: 5 ~12 NTU
Red Tide: Occasionally
TSS: 20~30 PPM
Gulf Area
3
Gulf Sea
Red Sea
TDS : HIGH
Turbidity : 7~12 NTU (PEAK 50)
TSS: 20~30PPM (PEAK 80PPM)
Temp. : 15~35℃
TDS : RELATIVE LOW
Turbidity : 1~2.5 NTU
TSS: 1~2.5 PPM
Temp. : 25~35℃
RAS LAFFAN
9
DIFFICULTIES FOR SWRO IN GULF AREA
Salinity
(TDS, ppm)
Turbidity
(NTU)
TSS
(Total suspended
Solid, ppm)
Gulf Area Difficulty
• Highest salinity in the
world (45,000ppm)
• Recovery ratio to be
decreased
• Shorten life time of
membrane
• 5~12 NTU
• Peak 50 NTU
• Conservative
pretreatment design to
be required (2~3 stage)
• 20~30 ppm
• Peak 80 ppm
• Conservative
pretreatment design to
be required (< 5ppm)
• Occasionally • Reliability to be
decreased sharply
• DAF is essential system
• Beach well can be
required.
Red Tide
High CAPEX for
sufficient pretreatment
Low recovery ratio
Low reliability
High O&M Cost
10
INTRODUCTION: MED TECHNOLOGY
Multi-Effect Distillation (MED) is an advanced form of thermal desalination now playing a
major role in large-scale desalination projects with the higher efficiency.
11
INTRODUCTION: BENEFITS OF ADVANCED HT-MED
Increasing TBT 65  85°C allows 50% increase in MED efficiency (GOR* & PR**).
= ~33% Steam Saving to produce the same amount of water
Typical MED: 10kg Water from 1kg Steam
1
2
1
2 2 1 1
steam
2 1 1
10 water
65°C 61 57 53 49 45 41°C
New HT MED: 15kg Water from 1kg Steam
1
2
GOR = 15
1
2 2 2 1 1
1 1 1 1
steam
1 15 water
85°C 81 77 73 69 65 61 57 53 49 45 41°C
1 1
33% less energy
to produce same water
GOR = 10
* GOR: Gain Output Ratio = product water [kg] / steam consumption [kg]
** PR: Performance Ratio = product water [kg] x 2,326 [kJ/kg] / energy input by steam [kJ]
12
INTRODUCTION: BENEFITS OF ADVANCED HT-MED
Steam
Global Water Intelligence, Vol. 11, Issue 9, Sep. 2010, p. 8
Relative operating costs of the main desalination process -33% less steam
consumption
Energy cost is a huge portion in desalting seawater.
Saving steam consumption in HT-MED reduces the water production cost of MED.
13
MED-TVC TECHNOLOGY DEVELOPMENT
◎ High Performance (PR 10  15+) MED
- Breakthrough in MED EFFICIENCY (by 50+%)
: Steam & Seawater Saving 30+%
(2008)
JDA w/ Chemical
Supplier for HT MED
& MSF
(2009)
20MIGD 85°C Design
Pilot: 75~95°C
(2010-12)
0.1MIGD 85°C
Demonstration
(2014)
Shoaiba Alt. Proposal
20MIGD, PR=19.5
Towards
World’s most
efficient MED
(2016-17)
HT-MED
Demonstration w/
SWCC
14
PREVIOUS STUDY: 24 ton/day Pilot
 29 experiments
 Feed TDS up to 64,000ppm
(MENA tube bundle bottom)
 Temperature: 75~95 °C
 Feed flow: 700~1,100 kg/hr
 New chemicals tested
 TBT 85°C achievable!!
2008~2009
[2008-2009] 24 ton/day Pilot in Korea - precise experiments for different conditions
: TBT 85°C is targeted after 29 experiments for 75~95°C
15
 0.1MIGD High Temperature MED-TVC with Brine-Recirculation
- Top Brine Temperature: 85'C
- Bottom Brine Temperature: 67’C
- Sea water intake: 30~40 (ton/hr), 20'C, 27,000~32,000 ppm
- Total feed water supply: 60~70 (ton/hr), 65'C, 45,000~53,000 ppm
- Distillate production: 17 t/h = 0.1 MIGD (410 t/d)
• TVC performance test
• Feed optimization test
• Anti-scalant dosage rate test
• Long term operational demonstration
PREVIOUS STUDY: 410 ton/day Pilot Demonstration
[2010~2012] Demonstration of TBT 85°C MED-TVC with industrial-size pilot (410 ton/day) in
Korea
16
PREVIOUS STUDY: 410 ton/day Pilot Demonstration
Sampling Tubes
- 1st Effect: #1~5, 7
- 2nd Effect: #1~3, 5
- 5th Effect: #1~3, 5
steam in
sample A
50cm
sample B
50cm
50cm 50cm
 A/S Supplier: Scale Analysis
with AAS, SEM, XRD
At the end of each experimental case, tubes were sampled and shipped to A/S Supplier for
further analysis.
17
PREVIOUS STUDY: 410 ton/day Pilot Demonstration
▶ SEM
- Coupon surface totally covered with a thin scale layer
▶ XRD
- Indicates that scale is only based on amorphous species
SOFT SCALE
▶ AAS (Tube)
- scale detected in Effect #1
- very low scale detected in Effect #2
- very low scale detected in Effect #5
As a result of chemical composition analysis, it was shown that soft scale was dominant in
the scale deposition as an amorphous species.
18
JOINT DEMONSTRATION WITH SWCC-DTRI
< Signing Ceremony >
 Date: 7th Feb, 2016
 Collaboration Period
: 3 years (2016 ~ 2018)
 Collaboration Target
- Demonstration of High Temperature (TBT
85°C) MED-TVC at Gulf Water condition
with DTRI(SWCC)
 Signing Ceremony for HT MED Collaboration Project
19
JOINT DEMONSTRATION WITH SWCC-DTRI
DTRI MED Pilot
- Location: DTRI in Jubail
- Capacity: 1.3 ton/hr
- Type: Brine Recirculation MED-TVC
- No. of Effect: 4
- Tube Material: Titanium
- No. of Pass: 2
- Feed Type: Tray + Perforated plate
 DTRI MED Pilot
 Operating Condition of 5 Months Scale Test
- Top Brine Temperature: 85°C
- Bottom Brine Temperature: 78°C
- Total feed water supply: 35 ton/hr, 60,000~63,000 ppm
- Distillate production: 1 ton/hr
20
JOINT DEMONSTRATION with SWCC-DTRI
Feed Seawater
Distillate condenser
E1 E2 E3 E4
Steam from boiler
Distillate
Brine blowdown
TVC
Cooling water
Seawater
 MED Pilot Schematic Diagram
Shutdown due to electricity supply issue
OPERATION DATA : TEMPERATURE PROFILE
Stable Operation
OPERATION DATA: FLOWRATE & CONCENTRATION PROFILE
Stable Operation
FOULING FACTOR ANALYSIS: HTC* & FF** PROFILE
*HTC, Heat transfer coefficient
**FF, Fouling factor
Stable Operation
FOULING FACTOR ANALYSIS: HTC* & FF** PROFILE
• Expected Trend of Overall Fouling Factor Increase
FF value is expected to be less than the design value after 1 year
(1 year)
- Breakthrough point: 18,858hrs(2.15yrs)
VISUAL INSPECTION REUSULT
VISUAL INSPECTION REUSULT
• Before 5-month Scale Test
• After 5-month Scale Test
After 5-month test, very thin film layer was entirely formed on the tube, which
expected to be soft scale
VISUAL INSPECTION REUSULT
• Before 5-month Scale Test • After 5-month Scale Test • Cleaning with water
Very thin film layer was easily removed after water flushing and scale
composition was confirmed as mostly CaCO3 (Soft Scale) by chemical analysis
• Chemical composition analysis
- CaCO3 is a dominant part of scale.
• Comparing to conventional MED-TVC (PR 11.5), High TBT MED-TVC plant (PR 18.3) has
significant improvement in HTC and reduction in OPEX
- Steam consumption reduction: Over 30%
- LCOW* reduction: 6.4 %
TECHNO-ECONOMIC ANALYSIS
100%
86%
80%
84%
- Based on Fuel Cost of 24 USD/bbl
*LCOW, Levelized cost of Water
 Based on technical and experimental studies (2008~2012), high TBT (85°C) MED-TVC is a
competitive technology.
 PR is increased from 9-11 to 13.5-15.8 kg distillate/2,326kJ
 33% Less Steam Consumption
 SWCC-Doosan Joint Demonstration (5 months) verified the High TBT (85°C) MED-TVC
technology under Jubail seawater condition (2016~2017).
 HTC & FF monitoring: Consistent HTC and FF trend show high TBT (85°C) MED-TVC
operation can be achieved.
 Visual inspection: Only thin film soft scale appeared on the tube surface, which can
be easily removed by water flushing
Chemical analysis: Ongoing to verify scale composition
 Based on demonstration test, it is proved that HT MED-TVC is technologically viable in
Gulf Area.
CONCLUDING REMARKS
Building Your Tomorrow Today

More Related Content

Similar to younggeun_Lee.pdf

Protec zld based on ltd system 2
Protec zld based on ltd system 2Protec zld based on ltd system 2
Protec zld based on ltd system 2mohager4a
 
Plastics to hydrogen
Plastics to hydrogenPlastics to hydrogen
Plastics to hydrogenRecupera
 
Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019
Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019
Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019Nicole Renee Pendini
 
Oil Sands Water Management Initiative Notes
Oil Sands Water Management Initiative NotesOil Sands Water Management Initiative Notes
Oil Sands Water Management Initiative Noteswilliampatricklaw
 
DeepOcean Presentation - Pareto Securities Conference
DeepOcean Presentation - Pareto Securities ConferenceDeepOcean Presentation - Pareto Securities Conference
DeepOcean Presentation - Pareto Securities ConferenceTom Nightingale
 
12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....
12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....
12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....JessJavierAntuaCouce
 
L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...
L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...
L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...Sardegna Ricerche
 
P&U Operations Review Presentation_14032019.pptx
P&U Operations Review Presentation_14032019.pptxP&U Operations Review Presentation_14032019.pptx
P&U Operations Review Presentation_14032019.pptxAastharaj16
 
IRJET- Experimental Analysis on Power Generation Unit using R134a Powered...
IRJET-  	  Experimental Analysis on Power Generation Unit using R134a Powered...IRJET-  	  Experimental Analysis on Power Generation Unit using R134a Powered...
IRJET- Experimental Analysis on Power Generation Unit using R134a Powered...IRJET Journal
 
Pvr presentation 20150707
Pvr presentation   20150707Pvr presentation   20150707
Pvr presentation 20150707danielfarb
 
Pioneer Turbine
Pioneer TurbinePioneer Turbine
Pioneer Turbineengomar84
 
Pvr presentation 20150707
Pvr presentation   20150707Pvr presentation   20150707
Pvr presentation 20150707danielfarb
 
CFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINE
CFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINECFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINE
CFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINEIRJET Journal
 
Circulating water treatment project
Circulating water treatment projectCirculating water treatment project
Circulating water treatment projectMolla Morshad
 
Effect of Solar Daylighting on Indoor Visual Environment for an Office Space
Effect of Solar Daylighting on Indoor Visual Environment for an Office SpaceEffect of Solar Daylighting on Indoor Visual Environment for an Office Space
Effect of Solar Daylighting on Indoor Visual Environment for an Office Spaceiskandaruz
 
Operation of Solar and Waste-heat Powered Adsorption Desalination
Operation of Solar and Waste-heat Powered Adsorption DesalinationOperation of Solar and Waste-heat Powered Adsorption Desalination
Operation of Solar and Waste-heat Powered Adsorption Desalinationiskandaruz
 

Similar to younggeun_Lee.pdf (20)

Protec zld based on ltd system 2
Protec zld based on ltd system 2Protec zld based on ltd system 2
Protec zld based on ltd system 2
 
Plastics to hydrogen
Plastics to hydrogenPlastics to hydrogen
Plastics to hydrogen
 
Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019
Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019
Australasian Lab managers Conference: Gas Generation Dr Nicole Pendini 2019
 
Oil Sands Water Management Initiative Notes
Oil Sands Water Management Initiative NotesOil Sands Water Management Initiative Notes
Oil Sands Water Management Initiative Notes
 
DeepOcean Presentation - Pareto Securities Conference
DeepOcean Presentation - Pareto Securities ConferenceDeepOcean Presentation - Pareto Securities Conference
DeepOcean Presentation - Pareto Securities Conference
 
Chemtronics Green STP AD+
Chemtronics  Green STP AD+Chemtronics  Green STP AD+
Chemtronics Green STP AD+
 
Catalyst materials for solar refineries, synthetic fuels and procedures for a...
Catalyst materials for solar refineries, synthetic fuels and procedures for a...Catalyst materials for solar refineries, synthetic fuels and procedures for a...
Catalyst materials for solar refineries, synthetic fuels and procedures for a...
 
12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....
12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....
12.10-IWFA-Annual-Conference-2014-Flow-battery-Technology-John-Ward-REDT-MNG....
 
L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...
L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...
L’impronta idrica della produzione di idrogeno elettrolitico su larga scala -...
 
P&U Operations Review Presentation_14032019.pptx
P&U Operations Review Presentation_14032019.pptxP&U Operations Review Presentation_14032019.pptx
P&U Operations Review Presentation_14032019.pptx
 
IRJET- Experimental Analysis on Power Generation Unit using R134a Powered...
IRJET-  	  Experimental Analysis on Power Generation Unit using R134a Powered...IRJET-  	  Experimental Analysis on Power Generation Unit using R134a Powered...
IRJET- Experimental Analysis on Power Generation Unit using R134a Powered...
 
Pvr presentation 20150707
Pvr presentation   20150707Pvr presentation   20150707
Pvr presentation 20150707
 
Pioneer Turbine
Pioneer TurbinePioneer Turbine
Pioneer Turbine
 
Pvr presentation 20150707
Pvr presentation   20150707Pvr presentation   20150707
Pvr presentation 20150707
 
CFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINE
CFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINECFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINE
CFD STUDIES ON MODELING OF SAVONIUS HYDRO TURBINE
 
Circulating water treatment project
Circulating water treatment projectCirculating water treatment project
Circulating water treatment project
 
Effect of Solar Daylighting on Indoor Visual Environment for an Office Space
Effect of Solar Daylighting on Indoor Visual Environment for an Office SpaceEffect of Solar Daylighting on Indoor Visual Environment for an Office Space
Effect of Solar Daylighting on Indoor Visual Environment for an Office Space
 
Operation of Solar and Waste-heat Powered Adsorption Desalination
Operation of Solar and Waste-heat Powered Adsorption DesalinationOperation of Solar and Waste-heat Powered Adsorption Desalination
Operation of Solar and Waste-heat Powered Adsorption Desalination
 
Ge remove oxygen
Ge   remove oxygenGe   remove oxygen
Ge remove oxygen
 
GHG Emision from Vessel
GHG Emision from VesselGHG Emision from Vessel
GHG Emision from Vessel
 

Recently uploaded

VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)dollysharma2066
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.eptoze12
 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and usesDevarapalliHaritha
 
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEINFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEroselinkalist12
 

Recently uploaded (20)

★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
POWER SYSTEMS-1 Complete notes examples
POWER SYSTEMS-1 Complete notes  examplesPOWER SYSTEMS-1 Complete notes  examples
POWER SYSTEMS-1 Complete notes examples
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
Design and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdfDesign and analysis of solar grass cutter.pdf
Design and analysis of solar grass cutter.pdf
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and uses
 
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETEINFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
 

younggeun_Lee.pdf

  • 1. High TBT (85°C) MED Technology Development Osman A. Hamed, Khalid Bamardouf, Abdulaziz S. Al-Jamhan, Faisal A. Abu Derman Desalination Technologies Research Institute (DTRI) Saline Water Conversion Corporation (SWCC) Younggeun Lee*, Amr M. Ahmed, Byungsung Park, Seungwon Ihm Doosan Water R&D Center Dammam, KSA
  • 2. 1 TABLE OF CONTENTS INTRODUCTION WATER BUSINESS IN DOOSAN BUSINESS GROUPS INTRODUCTION TO DOOSAN WATER PREVIOUS STUDY IN KOREA CONCLUDING REMARKS JOINT DEMONSTRATION IN KSA HT MED TECHNOLOGY DEVELOPMENT
  • 3. 2 DOOSAN HEAVY INDUSTRIES & CONSTRUCTION CASTING & FORGING POWER WATER EPC Global Leader in power and water Front Runner in industrial plants At Doosan Heavy Industries & Construction, our vision is to be a global leader in power and water, and we are committed to helping our clients meet tomorrow’s challenges and opportunities. NUCLEAR • Revenue: US$18.1 billion • Employees: 8,200 (2014 figures / Locally hired employees excluded) Boost in global business competencies Renewable Energy for our future Doosan IMGB Doosan Skoda Power Doosan Babcook Doosan Lentjes Doosan Power System India Doosan VINA Doosan Hydro Technology Doosan Enpure
  • 4. DESALINATION TECHNOLOGIES RO (REVERSE OSMOSIS) World’s largest RO train with application of 16-inch membranes MED (MULTI-EFFECT DISTILLATION) High TBT MED-TVC MSF (MULTI-STAGE FLASH) Large-scale unit, one-module fabrication, and hybrid solution World’s Largest Multi-Effect Distillation (MED) Distiller Location : Yanbu, Saudi Arabia Client : SWCC Distiller Unit Capacity : 15MIGD (68,190m³/day) Configuration : 15 MIGD x 1 unit Gain Output Ratio : 9.7 Delivery : 18 months [Yanbu Ph.2 Exp. MED] KSA [Busan Gijang RO] Korea [Escondida Water Supply] Chile Largest Desalination Plant in South America Capacity : 47.5MIGD (215,935m³/day) Pretreatment : Pressurized DMF Configuration : 5.3MIGD x 9 trains Feed water TDS : 39,300 mg/L Product water TDS : < 700 mg/L Client : Minera Escondida (BHP Billiton) Currently delivering the project for the world’s largest copper mining operation World’s Largest Desalination Plant with Hybrid Config. (MSF + RO) Capacity : 228MIGD (1,036,488m³/day) Location : Ras Al Khair, Saudi Arabia Client : Saline Water Conversion Corporation (SWCC) Evaporator Unit Capacity : 20MIGD (90,920m³/day) Configuration : 20 MIGD x 8 units Performance Ratio : 9.5 Dimensions(m) : W118.8 x L24.3 x H11.4 [Ras Al Khair Ph.1 Hybrid] KSA 3
  • 5. OPERATION & MAINTENANCE World’s Largest Desalination Plant (Hybrid (MSF+RO)) Capacity : 228MIGD (1,036,488m³/day) Pretreatment : DAF+DMF+Cartridge filters TDS : 45,000 mg/L O&M Period : 6 years (’13.12~’19.4) Client : SWCC Simultaneous service for both thermal (MSF) and SWRO plants * Information & Communication Technology Korea’s First Large-scale Desalination Plant Capacity : 10MIGD (45,460m³/day) Pretreatment : DABF+UF/DABF+DMF+C.F. TDS : 34,500 mg/L O&M Period : 20 years (’14.7~’34.6) Client : Busan Metropolitan City Service for the world’s largest capacity RO train (8MIGD) with 16-inch membranes [Shuwaikh RO] Kuwait [Ras Al Khair Ph.1] Saudi Arabia [Busan Gijang RO] Korea O&M Optimization Know-how Based on commissioning experience with over 20 plants Flexibility Offered through a unified channel (EPC + O&M) Efficiency Provided through ICT* solutions Kuwait’s First SWRO Desalination Plant Capacity : 30MIGD (136,380m³/day) Pretreatment : DAF+UF TDS : 45,000 mg/L O&M Period : 3 years (’11.10~’14.10) Client : Ministry of Electricity & Water Challenging conditions including frequent red tides events and high TDS 4
  • 6. 5 REFERENCES MORE THAN 20 LARGE-SCALE DESALINATION PLANT REFERENCES IN MENA AREA * 7 million ton/day ** 300 liter/person Shoaiba Ph.4 Doha RO Ph.1 Escondida SWRO Yanbu Ph.3 Marafiq MED Yanbu MED Ras Al Khair Ph.1 Jeddah RO Ph.3 Shuweihat S2 Shuwaikh RO Shuaibah Ph.3 Exp.RO Shuaibah Ph.3 IWPP Sabiya Ph.3 Sabiya Ph. 1&2 Ras Laffan B Sohar Fujairah Hybrid 88 60 47.5 121 12 15 228 53 100 30 30 194 50 60 33 50 100 RO RO RO MSF MED MED MSF+RO RO MSF RO RO MSF MSF MSF MSF MSF MSF+RO Project Name Capacity (MIGD) Type Construction Period ’05 ’04 ’06 ’07 ’08 ’09 ’10 ’11 ’12 ’13 References & Records KSA Kuwait Chile KSA KSA KSA KSA KSA UAE Kuwait KSA KSA Kuwait Kuwait Qatar Oman UAE Country Total of 33 Projects :1,626 MIGD* For daily use by 24.7 million people** ’14 ’15 1 MIGD (Million Imperial Gallon per Day) = 4,546 m3/day water production ’16 ’17
  • 7. 6 TABLE OF CONTENTS INTRODUCTION WATER BUSINESS IN DOOSAN BUSINESS GROUPS INTRODUCTION TO DOOSAN WATER PREVIOUS STUDY IN KOREA CONCLUDING REMARKS JOINT DEMONSTRATION IN KSA HT MED TECHNOLOGY DEVELOPMENT
  • 9. 8 COMPARISON FOR SEAWATER CONDITION 1 2 3 4 5 TDS: less 35,000 ppm Turbidity: less 2 NTU Red Tide: Rare1 Singapore 4 Seawater condition in Gulf area is much worse than any other region. TDS: less 38,000 ppm Turbidity:3~6 NTU Red Tide: Rare1 Chile 5 TDS: less 41,000 ppm Turbidity: less 2 NTU Red Tide: None 1 Mediterranean 2 TDS: less 40,000 ppm Turbidity: less 2 NTU Red Tide: None 1 Spain 1 TDS: over 45,000 ppm Turbidity: 5 ~12 NTU Red Tide: Occasionally TSS: 20~30 PPM Gulf Area 3 Gulf Sea Red Sea TDS : HIGH Turbidity : 7~12 NTU (PEAK 50) TSS: 20~30PPM (PEAK 80PPM) Temp. : 15~35℃ TDS : RELATIVE LOW Turbidity : 1~2.5 NTU TSS: 1~2.5 PPM Temp. : 25~35℃ RAS LAFFAN
  • 10. 9 DIFFICULTIES FOR SWRO IN GULF AREA Salinity (TDS, ppm) Turbidity (NTU) TSS (Total suspended Solid, ppm) Gulf Area Difficulty • Highest salinity in the world (45,000ppm) • Recovery ratio to be decreased • Shorten life time of membrane • 5~12 NTU • Peak 50 NTU • Conservative pretreatment design to be required (2~3 stage) • 20~30 ppm • Peak 80 ppm • Conservative pretreatment design to be required (< 5ppm) • Occasionally • Reliability to be decreased sharply • DAF is essential system • Beach well can be required. Red Tide High CAPEX for sufficient pretreatment Low recovery ratio Low reliability High O&M Cost
  • 11. 10 INTRODUCTION: MED TECHNOLOGY Multi-Effect Distillation (MED) is an advanced form of thermal desalination now playing a major role in large-scale desalination projects with the higher efficiency.
  • 12. 11 INTRODUCTION: BENEFITS OF ADVANCED HT-MED Increasing TBT 65  85°C allows 50% increase in MED efficiency (GOR* & PR**). = ~33% Steam Saving to produce the same amount of water Typical MED: 10kg Water from 1kg Steam 1 2 1 2 2 1 1 steam 2 1 1 10 water 65°C 61 57 53 49 45 41°C New HT MED: 15kg Water from 1kg Steam 1 2 GOR = 15 1 2 2 2 1 1 1 1 1 1 steam 1 15 water 85°C 81 77 73 69 65 61 57 53 49 45 41°C 1 1 33% less energy to produce same water GOR = 10 * GOR: Gain Output Ratio = product water [kg] / steam consumption [kg] ** PR: Performance Ratio = product water [kg] x 2,326 [kJ/kg] / energy input by steam [kJ]
  • 13. 12 INTRODUCTION: BENEFITS OF ADVANCED HT-MED Steam Global Water Intelligence, Vol. 11, Issue 9, Sep. 2010, p. 8 Relative operating costs of the main desalination process -33% less steam consumption Energy cost is a huge portion in desalting seawater. Saving steam consumption in HT-MED reduces the water production cost of MED.
  • 14. 13 MED-TVC TECHNOLOGY DEVELOPMENT ◎ High Performance (PR 10  15+) MED - Breakthrough in MED EFFICIENCY (by 50+%) : Steam & Seawater Saving 30+% (2008) JDA w/ Chemical Supplier for HT MED & MSF (2009) 20MIGD 85°C Design Pilot: 75~95°C (2010-12) 0.1MIGD 85°C Demonstration (2014) Shoaiba Alt. Proposal 20MIGD, PR=19.5 Towards World’s most efficient MED (2016-17) HT-MED Demonstration w/ SWCC
  • 15. 14 PREVIOUS STUDY: 24 ton/day Pilot  29 experiments  Feed TDS up to 64,000ppm (MENA tube bundle bottom)  Temperature: 75~95 °C  Feed flow: 700~1,100 kg/hr  New chemicals tested  TBT 85°C achievable!! 2008~2009 [2008-2009] 24 ton/day Pilot in Korea - precise experiments for different conditions : TBT 85°C is targeted after 29 experiments for 75~95°C
  • 16. 15  0.1MIGD High Temperature MED-TVC with Brine-Recirculation - Top Brine Temperature: 85'C - Bottom Brine Temperature: 67’C - Sea water intake: 30~40 (ton/hr), 20'C, 27,000~32,000 ppm - Total feed water supply: 60~70 (ton/hr), 65'C, 45,000~53,000 ppm - Distillate production: 17 t/h = 0.1 MIGD (410 t/d) • TVC performance test • Feed optimization test • Anti-scalant dosage rate test • Long term operational demonstration PREVIOUS STUDY: 410 ton/day Pilot Demonstration [2010~2012] Demonstration of TBT 85°C MED-TVC with industrial-size pilot (410 ton/day) in Korea
  • 17. 16 PREVIOUS STUDY: 410 ton/day Pilot Demonstration Sampling Tubes - 1st Effect: #1~5, 7 - 2nd Effect: #1~3, 5 - 5th Effect: #1~3, 5 steam in sample A 50cm sample B 50cm 50cm 50cm  A/S Supplier: Scale Analysis with AAS, SEM, XRD At the end of each experimental case, tubes were sampled and shipped to A/S Supplier for further analysis.
  • 18. 17 PREVIOUS STUDY: 410 ton/day Pilot Demonstration ▶ SEM - Coupon surface totally covered with a thin scale layer ▶ XRD - Indicates that scale is only based on amorphous species SOFT SCALE ▶ AAS (Tube) - scale detected in Effect #1 - very low scale detected in Effect #2 - very low scale detected in Effect #5 As a result of chemical composition analysis, it was shown that soft scale was dominant in the scale deposition as an amorphous species.
  • 19. 18 JOINT DEMONSTRATION WITH SWCC-DTRI < Signing Ceremony >  Date: 7th Feb, 2016  Collaboration Period : 3 years (2016 ~ 2018)  Collaboration Target - Demonstration of High Temperature (TBT 85°C) MED-TVC at Gulf Water condition with DTRI(SWCC)  Signing Ceremony for HT MED Collaboration Project
  • 20. 19 JOINT DEMONSTRATION WITH SWCC-DTRI DTRI MED Pilot - Location: DTRI in Jubail - Capacity: 1.3 ton/hr - Type: Brine Recirculation MED-TVC - No. of Effect: 4 - Tube Material: Titanium - No. of Pass: 2 - Feed Type: Tray + Perforated plate  DTRI MED Pilot  Operating Condition of 5 Months Scale Test - Top Brine Temperature: 85°C - Bottom Brine Temperature: 78°C - Total feed water supply: 35 ton/hr, 60,000~63,000 ppm - Distillate production: 1 ton/hr
  • 21. 20 JOINT DEMONSTRATION with SWCC-DTRI Feed Seawater Distillate condenser E1 E2 E3 E4 Steam from boiler Distillate Brine blowdown TVC Cooling water Seawater  MED Pilot Schematic Diagram
  • 22. Shutdown due to electricity supply issue OPERATION DATA : TEMPERATURE PROFILE Stable Operation
  • 23. OPERATION DATA: FLOWRATE & CONCENTRATION PROFILE Stable Operation
  • 24. FOULING FACTOR ANALYSIS: HTC* & FF** PROFILE *HTC, Heat transfer coefficient **FF, Fouling factor Stable Operation
  • 25. FOULING FACTOR ANALYSIS: HTC* & FF** PROFILE • Expected Trend of Overall Fouling Factor Increase FF value is expected to be less than the design value after 1 year (1 year) - Breakthrough point: 18,858hrs(2.15yrs)
  • 27. VISUAL INSPECTION REUSULT • Before 5-month Scale Test • After 5-month Scale Test After 5-month test, very thin film layer was entirely formed on the tube, which expected to be soft scale
  • 28. VISUAL INSPECTION REUSULT • Before 5-month Scale Test • After 5-month Scale Test • Cleaning with water Very thin film layer was easily removed after water flushing and scale composition was confirmed as mostly CaCO3 (Soft Scale) by chemical analysis • Chemical composition analysis - CaCO3 is a dominant part of scale.
  • 29. • Comparing to conventional MED-TVC (PR 11.5), High TBT MED-TVC plant (PR 18.3) has significant improvement in HTC and reduction in OPEX - Steam consumption reduction: Over 30% - LCOW* reduction: 6.4 % TECHNO-ECONOMIC ANALYSIS 100% 86% 80% 84% - Based on Fuel Cost of 24 USD/bbl *LCOW, Levelized cost of Water
  • 30.  Based on technical and experimental studies (2008~2012), high TBT (85°C) MED-TVC is a competitive technology.  PR is increased from 9-11 to 13.5-15.8 kg distillate/2,326kJ  33% Less Steam Consumption  SWCC-Doosan Joint Demonstration (5 months) verified the High TBT (85°C) MED-TVC technology under Jubail seawater condition (2016~2017).  HTC & FF monitoring: Consistent HTC and FF trend show high TBT (85°C) MED-TVC operation can be achieved.  Visual inspection: Only thin film soft scale appeared on the tube surface, which can be easily removed by water flushing Chemical analysis: Ongoing to verify scale composition  Based on demonstration test, it is proved that HT MED-TVC is technologically viable in Gulf Area. CONCLUDING REMARKS