Design Specifications:
The Pressure Right acupressure relief wrist strip measures (5.50” long X 1.0” wide) in size, with
an affixed hard plastic button. The placement of the affixed plastic button is positioned
approximately 1 ½ inches from the end of the wrist strip. The size of the plastic button is 0.52”
in diameter X 0.27” high.
The Pressure Right wrist strip material is a 3M™ Transpore Surgical Tape manufactured from a
low-density perforated polyethylene film with a hypoallergenic, pressure-sensitive, acrylate
adhesive.
The Pressure Right plastic button raw material is made from acrylonitrile butadiene styrene
(Lustran ABS 348) medical grade. The manufacturer’s injection molding process creates the
hard plastic button from the raw material.
Summary:
The Pressure Right primary components consist of the pressure-sensitive adhesive and the
affixed hard plastic button. The combination of these two components provides the wrist
acupressure relief mechanism for the product’s intended purpose.

More Related Content

More from Painezee Specialist

ZMPCZM019000.12.07 NeuroGraph User's manual
ZMPCZM019000.12.07 NeuroGraph User's manualZMPCZM019000.12.07 NeuroGraph User's manual
ZMPCZM019000.12.07 NeuroGraph User's manualPainezee Specialist
 
ZMPCZM019000.12.06 NeuroGames User's manual
ZMPCZM019000.12.06 NeuroGames User's manualZMPCZM019000.12.06 NeuroGames User's manual
ZMPCZM019000.12.06 NeuroGames User's manualPainezee Specialist
 
ZMPCZM019000.12.05 Incontinence user's manual
ZMPCZM019000.12.05 Incontinence user's manualZMPCZM019000.12.05 Incontinence user's manual
ZMPCZM019000.12.05 Incontinence user's manualPainezee Specialist
 
ZMPCZM019000.12.04 Head Ache User's Manual
ZMPCZM019000.12.04 Head Ache User's ManualZMPCZM019000.12.04 Head Ache User's Manual
ZMPCZM019000.12.04 Head Ache User's ManualPainezee Specialist
 
ZMPCZM019000.12.03 Chiro Scan User's guide
ZMPCZM019000.12.03 Chiro Scan User's guideZMPCZM019000.12.03 Chiro Scan User's guide
ZMPCZM019000.12.03 Chiro Scan User's guidePainezee Specialist
 
ZMPCZM016000.12.16 Electrode placement & Protocol Guidelines
ZMPCZM016000.12.16 Electrode placement & Protocol GuidelinesZMPCZM016000.12.16 Electrode placement & Protocol Guidelines
ZMPCZM016000.12.16 Electrode placement & Protocol GuidelinesPainezee Specialist
 
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementPainezee Specialist
 
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementPainezee Specialist
 
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementPainezee Specialist
 

More from Painezee Specialist (20)

Zywie
ZywieZywie
Zywie
 
ZMPCZM019000.10.01
ZMPCZM019000.10.01ZMPCZM019000.10.01
ZMPCZM019000.10.01
 
ZMPCZM016000.12.07
ZMPCZM016000.12.07ZMPCZM016000.12.07
ZMPCZM016000.12.07
 
ZMPCZM016000.12.06
ZMPCZM016000.12.06ZMPCZM016000.12.06
ZMPCZM016000.12.06
 
ZMPCZM019000.12.07 NeuroGraph User's manual
ZMPCZM019000.12.07 NeuroGraph User's manualZMPCZM019000.12.07 NeuroGraph User's manual
ZMPCZM019000.12.07 NeuroGraph User's manual
 
ZMPCZM019000.12.06 NeuroGames User's manual
ZMPCZM019000.12.06 NeuroGames User's manualZMPCZM019000.12.06 NeuroGames User's manual
ZMPCZM019000.12.06 NeuroGames User's manual
 
ZMPCZM019000.12.05 Incontinence user's manual
ZMPCZM019000.12.05 Incontinence user's manualZMPCZM019000.12.05 Incontinence user's manual
ZMPCZM019000.12.05 Incontinence user's manual
 
ZMPCZM019000.12.04 Head Ache User's Manual
ZMPCZM019000.12.04 Head Ache User's ManualZMPCZM019000.12.04 Head Ache User's Manual
ZMPCZM019000.12.04 Head Ache User's Manual
 
ZMPCZM019000.12.03 Chiro Scan User's guide
ZMPCZM019000.12.03 Chiro Scan User's guideZMPCZM019000.12.03 Chiro Scan User's guide
ZMPCZM019000.12.03 Chiro Scan User's guide
 
ZMPCZM016000.12.16 Electrode placement & Protocol Guidelines
ZMPCZM016000.12.16 Electrode placement & Protocol GuidelinesZMPCZM016000.12.16 Electrode placement & Protocol Guidelines
ZMPCZM016000.12.16 Electrode placement & Protocol Guidelines
 
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
 
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
 
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placementZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
ZMPCZM016000.12.14 Hand,Wrist,Elbow & upperarm electrode placement
 
ZMPCHW070000.13.07
ZMPCHW070000.13.07ZMPCHW070000.13.07
ZMPCHW070000.13.07
 
ZMPCZM017000.11.11
ZMPCZM017000.11.11ZMPCZM017000.11.11
ZMPCZM017000.11.11
 
ZMPCZM017000.11.10
ZMPCZM017000.11.10ZMPCZM017000.11.10
ZMPCZM017000.11.10
 
ZMPCZM017000.11.09
ZMPCZM017000.11.09ZMPCZM017000.11.09
ZMPCZM017000.11.09
 
ZMPCZM017000.11.08
ZMPCZM017000.11.08ZMPCZM017000.11.08
ZMPCZM017000.11.08
 
ZMPCZM017000.11.07
ZMPCZM017000.11.07ZMPCZM017000.11.07
ZMPCZM017000.11.07
 
ZMPCZM017000.11.06
ZMPCZM017000.11.06ZMPCZM017000.11.06
ZMPCZM017000.11.06
 

ZMGYPP100000 Pressure right design_specifications

  • 1. Design Specifications: The Pressure Right acupressure relief wrist strip measures (5.50” long X 1.0” wide) in size, with an affixed hard plastic button. The placement of the affixed plastic button is positioned approximately 1 ½ inches from the end of the wrist strip. The size of the plastic button is 0.52” in diameter X 0.27” high. The Pressure Right wrist strip material is a 3M™ Transpore Surgical Tape manufactured from a low-density perforated polyethylene film with a hypoallergenic, pressure-sensitive, acrylate adhesive. The Pressure Right plastic button raw material is made from acrylonitrile butadiene styrene (Lustran ABS 348) medical grade. The manufacturer’s injection molding process creates the hard plastic button from the raw material. Summary: The Pressure Right primary components consist of the pressure-sensitive adhesive and the affixed hard plastic button. The combination of these two components provides the wrist acupressure relief mechanism for the product’s intended purpose.