2. CARPET AREA
THE CARPET AREA IS THE DISTANCE BETWEEN THE
INNER WALLS. COMMON AREAS SUCH AS LIFT, LOBBY,
ETC. ARE NOT INCLUDED UNDER THE CARPET AREA.
ACCORDING TO REAL ESTATE REGULATORY
AUTHORITY (RERA), CARPET AREA MEANS THE NET
USABLE FLOOR AREA OF AN APARTMENT, EXCLUDING
THE AREA COVERED BY THE EXTERNAL WALLS, AREAS
UNDER SERVICES SHAFTS, EXCLUSIVE BALCONY OR
VERANDAH AREA AND EXCLUSIVE OPEN TERRACE
AREA, BUT INCLUDES THE AREA COVERED BY THE
INTERNAL PARTITION WALLS OF THE APARTMENT.
3. BUILT UP AREA
BUILT UP AREA OF A PREMISE IS MEASURED
FROM THE EXTERNAL PERIMETER WALL
SURFACES.
IT IS THE CARPET AREA + WALL
THICKNESS,ALONG WITH OTHER UNUSEABLE
AREA WITHIN THE APARTMENT(E.G.:DRY
BALCONY,,TERRACE,FLOWER BEDS.
BUILT UP AREA =CARPET AREA + AREA OF
WALLS
4. SUPER BUILT UP AREA
SUPER BUILT UP AREA OF A PREMISE IS THE SALEABLE
AREA,WHICH INCLUDES THE CARET AREA,ALONG WITH
TERRACE,BALCONIES,AREA OCCUPIED BY WALLS AND AREA
OCCUPIED BY COMMON/SHARED CONSTRUCTION(E.G.:LIFT
,STAIRS,ETC.)
IN SOME CASES BUILDERS INCLIDE AMENITIES LIKE
POOL,,CLUBHOUSEAND GARDEN,THEY USE THE LOADING FACTOR
ON CARPET AREA TO ARRIVE AT THE SUPER BUILT UP AREA.
ACCORDING TO RERA(REAL ESTATE REGULATORY
AUTHORITY),THE CARPET AREA,BUILT UP AREA,,AS WELL AS THE
SHARE OF THE COMMMON AREA LIKE STAIRS,LOBBIES,THAT CAN
BE USED BY THE ENTIRE BUILDING IS DEFINED AS SUPEER BUILT
UP AREA.
SUPER BUILT UP AREA=BUILT UP AREA + COMMON AREAS.
5. FSI CALUCLATION
IT IS THE RATIO BETWEEN THE AREA OF A
COVERED FLOOR(BUILT UP AREA) TO THE
AREA OF THAT PLOT ON WHICH A
BUILDING STANDS.
FSI=FLOOR SPACE COVERED IN ALL
FLOORS/AREA OF THE PLOT
FSI IS REGULATED BY
DTCP(DIRECTORATE OF TOWN AND
COUNTRY PLANNING).
6. BUILDING HEIGHT LEVELS
GENERALLY FLOOR TO FLOOR HEIGHT IS 7.5FT IN RESIDENTIAL
BUILDING
IN COMMERCIAL BUILDING FLOOR TO FLOOR HEIGHT SHOULD BE
10FT.
PLINTH:GENERAL HEIGHT FOR PLINTH SHOULD BE 300-450MM FROM
G.L.
MINIMUM PLINTH HEIGHT ADOPTED FROM TOP OF ROAD SHOULD BE
150MM
SILL:SILL HEIGHT LEVEL DEPENDS ON TYPE OF ROOM,IN BEDROOM
AND BATHROOM THE SILL HEIGHT SHOULD BE AROUND MIN. 1100MM
DUE TO RIVACY CONCERNS AND IN LIVING ROOM THE SILL LEVEL IS
KEPT AT MINIMUM 600-650MM.
MINIMUM SILL LEVEL HEIGHT SHOULD BE 44INCHES.
LINTEL IS ALWAYS PROVIDED ABOVE DOORS AND WINDOWS.
7. BASIC STANDARDS:DOOR
DOOR TYPE HEIGHT WIDTH THICKNESS ADDITIONAL
COMMON SIZE
STANDARD 80” 36” 1 3/8 “ NA
STANDARD
INTERIOR DOOR
80” 36” 1 ¾”,1 3/8” 24”,28”,30”,32”,36”.
STANDARD
EXTERIOR DOOR
80” 36” 1 ¾” NA
SLIDING GLASS
DOOR
80” 60-72” NA 60”(H)
X96”(w),72”(H) X
96”(W),96”(H)X96”
(W)
FRENCH DOOR 80” 36” 1 ¾” 84”(H) X 96”(H)
24”(H)X 42”(W)
CLOSET DOOR 96” 30” 1 3/8” NA
9. STANDARD: ROOM SIZE NOTES
STANDARD ROOM SIZES OF LIVING ROOM,DRAWING ROOM,DINING
ROOM,STUDY ROOM
MINIMUM ROOM SIZE AREA:9.5 SQ.M.
STANDARD LIVING ROOM SIZE:9 FT X 10 FT.
MINIMUM SIZE OF SIDE:
FOR ONE ROOM MINIMUM WIDTH SHOULD BE 2.4M
WHEN TWO ROOMS PRESENT,ONE OF THEM SHOULD NOT BE LESS THA 9.5
SQ.M. AD OTHERS NOT LESS THAN 7.5 SQ.M. WITH A MINIMUM WIDTH OF 2.1 M.
HEIGHT OF ROOM:NOT LESS THAN 2.75 M MEASURE FROM SURFACE OF ALL
FLOORS.
OTHER REQUIREMENT:FOR AIR CONDITIONING ROOM HEIGHT SHOULD NOT BE
LESS THAN 2.4M.
11. STANDARD SIZE:BEDROOM
ROOM SIZE DIMENSION (FT) DIMESNSION(MT)
MIN. SIZE BEDROOM 9FT X 9 FT 2.74 M X 2.74M
MED. SIZE BEDROOM 12 FT X 12 FT 3.65 M X 3.65 M
LARGE SIZE BEDROOM 16 FT X 18 FT 4.87 M X 5.48 M
12. STANDARD SIZE:KITCHEN
ROOM SIZE DIMENSION (FT) DIMENSION(MT)
LARGE 12 X 20 (240) 3.65 X 6.09 (22.23)
MEDIUM 3.05 X4.87(14.85) 10 X 16 (160)
SMALL 3.05 X 2.44(610) 10 X 0.8 (80)
VERY SMALL 2.13 X 2.75(5.85) 0.7 X 0.9(63)
• MINIMUM AREA REQUIRED FOR KITCHEN:5 SQ.M.
• MINIMUM SIZE OF SIDE:
• WIDTH OF ROOM SHOULD NOT BE LESS THAN 1.8M,WHERE THERE IS A
SEPARATE STORE,THE AREA OF THE KITCHEN MAY BE REDUCED TO 4.5 SQ.M.
• A KITCHEN THAT IS INTENDED RO USE AS DINING ALSO SHALL HAVE A FLOOR
AREA OF NOT LESS THAN 7.5 SQ.M. WITH MINIMUM WIDTH OF 2.1M.
• THE HEIGHT OF ROOM:SHALL NOT BE LESS THAN 2.75 SQ.M.
OTHER REQUIREMENTS:
• ITS FLOOR SHOULD BE IMPERMEABLE
• UNLESS SEPARATELY PROVIDED IN A PANTRY,MEANS FOR WASHING OF
KITCHEN,UTENSILS,WHICH SHALL LEAD DIRECTLY OR THROUGH THE SINK TO A
GRADEDAND TRAPPED CONNECTION TO THE WASTE PIPE.
13. STANDARD:BATHROOM AND WATER CLOSET
MINIMUM AREA OF BATHROOM:1.8 SQ.M.
MINIMUM AREA OF W.C.: 1.1 SQ.M.
MINIMUM SIZE OF SIDE:IF BATH & WATER CLOSET ARE COMBINED ,ITS FLOOR AREA SHALL NOT
BE LESS THAN 2.8 SQ.M. WITH A MINIMUM SIDE,WIDTH OF 1.2 M.
HEIGHT OF ROOM-SHALL NOT BE LESS THAN 2 M.
OTHER REQUIREMENT:
IT SHOULD BE LOCATED SUCH THAT AT LEAST ONE OF ITS WALLS IS OPEN TO THE EXTERNAL
WALL.
IT SHOULD NOT BE DIRECTLY OVER OR UNDER ANY OTHER ROOM THAN ANOTHER
LATERINE,WASHING PLACE,BATH OR TERRACE,IN CASE OF MMULTI STOREYED BUILDING UNLESS
THE FLOOR IS WATERTIGHT.
IT SHOULD HAVE A PLATFORM OR SEAT OF WATER TIGHT,NON ABSORBANT MATERIALS.
IT SHOULD BE PROVIDED WITH THE IMPERVIOUS FLOOR SLOPING TOWARDS THE DRAIN WITH A
SUITABLE GRUDE V AND NOT TOWARDS VERANDAH OR ANY OTHER ROOMS.
14. STANDARD:BATHROOM AND WATER CLOSET
SIZE OF BATH OR WC DIMENSION IN MT (AREA) DIMENSION IN FT
LARGE 2.13 X 3.66(7.8) 7 X 12 (84)
MEDIUM 1.83 X 3.05 (5.60) 6X10 (60)
SMALL 1.52 X 2.75 (4.20) 5 X9 (45)
VERY SMALL 1.06 X 1.98 (2.04) 3.5 X6.5 (22.75)
15. STANDARDS: WALL
FOR WALL CONSTRUCTION INSIDE HOUSE THERE IS SEVERAL BUILDING MATERIAL
USED:
RED CLAY BRICK
STONE
AAC BLOCK
CONCRETE BLOCK
RCC OUTER WALL
IF USING BRICK WALL CONSTRUCTION,MINIMUM THICKNESS OF BRICK WALL
SHOULD BE KEPT AROUND 9IN (230MM) THICK FOR OUTER WALL, 4.5INCH(115MM)
THICK FOR INTERNAL WALL PARTITION AND 3 INCH (80MM)THICK FOR CUPBOARD
AND RAILING PURPOSE ,BECAUSE OF A STANDARD BRICK SIZE AVAILABLE IN 9” X
4.5” X 3” (230MMX115MMX75MM)
16. STANDARDS: WALL
IF WE ADOPT AAC BLOCK AND CONCRETE BLOCK IN PLACE OF RED CLAY
BRICKS,FOR WALL CONSTRUCTION FOR RESIDENTIAL/COMMERCIAL
BUILDINGS,STANDARD WALL THICKNESS.SHOULD BE KEPT AROUND 8
INCH(200MM) THICK FOR OUTER WALL & 4 INCH (100MM) THICK FOR INNER
WALL PARTITION.
IF WE ADOPT RCC WALL,LOAD BEARING STRUCTURE IN PLACE OF AAC
BLOCK,CONCRETE BLOCK AND RED CLAY BRICK, FOR WALL CONSTRUCTION FOR
RESIDENTIAL/COMMERCIAL BUILDING, STANDARD WALL THICKNESS SHOULD BE
KEPT AROUND 6 INCH (150 MM)THICK FOR OUTER WALL AND 3 INCH(80 MM)
THICK FOR INNER WALL PARTITION.
IN CONSTRUCTION OF RESIDENTIAL/ COMMERCIAL BUILDING .STANDARD
THICKNESS OF BRICK WALL SHOULD BE KEPT AROUND 9INCH (230 MM) THICK
FOR OUTER WALL ,4.5INCH (120 MM) THICK FOR INTERNAL WALL PARTITION
AND 3 INCH (80 MM) THICK FOR CUPBOARD AND RAILING PURPOSE.
17. STANDARDS: WALL
WALL THICKNESS IN MM:
IN BRICK WALL CONSTRUCTION,THEN MINIMUM WALL THICKNESS SHOULD BE KEPT
AROUND 230MM THICK FOR OUTER WALL,120MM THICK FOR INTERNAL WALL
PARTITION AND 80 MM THICK FOR CUPBOARD AND RAILING PURPOSE.
IF ADOPTING AAC BLOCK AND CONCRETE BLOCK THEN MINIMUM WALL THICKNESS
SHOULD BE REDUCED AROUND 200 MM THICK FOR OUTER WALL AND 100MM FOR
INNER WALL PARTITION.
IF ADOPTING RCC OUTER WALL ,THICKNESS CAN BE REDUCED 150MM.
WALL THICKNESS IN INCHES:
MINIMUM WALL THICKNESS SHOULD BE KEPT AROUND 9 INCHES THICK FOR OUTER
WALL,4.5 THICK FOR INTERNAL WALL PARTITION
2,3 INCH THICK FOR CUPBOARDAND RAILING PURPOSE.
IF WE ADOPT AAC BLOCK & CONCRETE BLOCK THEN MINIMUM WALL THICKNESS
SHOULD BE REDUCED AROUND 8INCH FOR OUTERWALL AND 4 INCH FOR INNER WALL
PARTITION
IF ADOPTING RCC OUTERWALL,THICKNESS CAN BE REDUCED 6INCH.
18. STANDARDS: WALL
WALL THICKNESS IN CM:
IN BRICK WALL CONSTRUCTION,THEN MINIMUM WALL THICKNESS SHOULD BE KEPT
AROUND 23CM THICK FOR OUTER WALL,12 CM THICK FOR INTERNAL WALL PARTITION
AND 8 CM THICK FOR CUPBOARD AND RAILING PURPOSE.
IF ADOPTING AAC BLOCK AND CONCRETE BLOCK THEN MINIMUM WALL THICKNESS
SHOULD BE REDUCED AROUND 20 CM THICK FOR OUTER WALL AND 10 CM FOR INNER
WALL PARTITION.
IF ADOPTING RCC OUTER WALL ,THICKNESS CAN BE REDUCED 15 CM.
WALL THICKNESS IN M:
MINIMUM WALL THICKNESS SHOULD BE KEPT AROUND 0.23M THICK FOR OUTER WALL,
.12M THICK FOR INTERNAL WALL PARTITION
.8M THICK FOR CUPBOARDAND RAILING PURPOSE.
IF WE ADOPT AAC BLOCK & CONCRETE BLOCK THEN MINIMUM WALL THICKNESS
SHOULD BE REDUCED AROUND .200M FOR OUTERWALL AND .10 FOR INNER WALL
PARTITION
IF ADOPTING RCC OUTERWALL,THICKNESS CAN BE 0.15M.
19. STANDARDS: WALL NOTES
WALL THICKNESS FOR BUILDING WITH RCC FRAMED STRUCTURE
NON LOAD BEARING WALL,MINIMUM REQUIRED WALL THICKNESS SHOULD BE
8INCH(200MM) THICK FOR OUTER WALL AND REDUCE THE COST,WE CAN REDUCE THE
THICKNESS TO 444INCH ((100MM) FOR INTERIOR WALL PARTITION IN RCC FRAME
STRUCTURE.
WALL THICKNESS FOR LOAD BEARING STRUCTURE
FOR ALL TYPE BUILDING, FOR LOAD BEARING STRUCTUREIN BRICK MASONRY WALL,
THICKNESS CAN BE 300MM TO 450MM FOR OUTERWALL G+2 HOUSE AND INTERNAL
WALL THICKNESS CAN BE 300MM -200MM ACCORDING TO SPAN AND ROOM SIZE.
IF WE ARE USING STONE FOR LOAD BEARING WALL,THICKNESS CAN BE 300 MM-450,450
MMFOR GROUND FLOOR,350 MM FOR 1ST FLOOR AND 300 MM FOR 2ND FLOOR.
IN OLD BUILDING WE CAN SEE BRICKWORK IS LIME MORTAR OF 450-600MM THICKNESS
IN GROUND FLOOR AND 300MM-450MM IN NEXT 2ND AND 3RD FLOOR.
20. STANDARD:FURNITURE:LIVING ROOM
THREE SEAT SOFA:38 IN DEEP X 90 IN WIDE
LOVE SEAT-38 INCHES DEEP X 60 IN WIDE
ARM CHAIR-35 INCHES DEEP X 35 INCHES WIDE
COFFEE TABLE-48 IN LONG X X30 IN WIDE
SQUARE AND TABLE –24 IN LONG X 24 IN WIDE
RECTANGULAR END TABLE-28 INCHES LONG X 25 INCHES
WIDE
FOUR SHELF BOOK CASE-34 IN TALL X 45 INCHES WIDE
21. STANDARD:FURNITURE:DINING ROOM
DINING TABLE WITH ONE LEAF-72IN LONG X
36 IN WIDE
ROUND DINING TABLE FOR FOUR PEOPLE-36
IN DIA TO 44 IN DIA.
SIDE CHAIR-18 IN DEEP X 18 IN WIDE
ARM CHAIR-18 IN DEEP X 22 IN WIDE
23. STANDARD:FURNITURE:BEDROOM
TWIN SIZE BED:39IN WIDE X 80 IN LONG
DOUBLE OR FULL SIZE BED:54 IN WIDEX80 IN LONG
QUEEN SIZE BED:60IN WIDE X 80 IN LONG
EASTERN KING SIZE BED:76IN WIDE X 80 IN LONG
CALIFORNIA LONG SIZE BED:72 IN WIDE X 84 IN LONG
CHEST OF DRAWERS:30IN WIDE X 18 IN DEEP
NIGHTSTAND:18 IN WIDE X 18 IN DEEP
24. STANDARD:FURNITURE:PATIO
RECTANGLE DINING TABLE:40-102IN LONGX42IN WIDEX28-
30IN AVG HT OF ANY SIZE & SHAPE TABLE
SQUARE DINING TABLE:30-64 IN SQUARE
COUNTER HEIGHT TABLE:34-36 IN TALL ANY SIZE AND
SHAPE TABLE.
COUNTER HEIGHT CHAIR/STOOL:24-26IN TALL FLOOR TO
TOP OF SEAT
CHAISE LOUNGE CHAIR:78 IN LONG X 20.5 IN WIDE
COFFEE END TABLE:15-19 TALL ANY SIZE AND SHAPE
FIRE PIT TABLE:20-25IN TALL SIZE AND SHAPE TABLE
25. STANDARD:FURNITURE:KITCHEN
SQUARE BREAKFAST TABLE FOR 4 PEOLE: 36 IN X 36 IN
DISHWASHER:24IN DEEPX35IN TALL
SIDE BY SIDE REFRIGERATOR:30-36 IN WIDEX 29-35 IN
DEEPX67-70IN TALL
BASE CABINET:36 IN WIDE X 24-26 IN DEEP X 35-36IN TALL
26. VASTU NOTES
SQUARE HOUSE IS CONSIDERED AUSPICIOUS
CORNER OF BUILDING SHOULD NOT BE CUT
CORNERS PROVIDE ENOUGH SUPPORT TO THE BUILDING AND SHOULD NOT BE TAMPERED
ONLY NORTH EAST CORNERCAN BE CUT OUT AND ADDITIONS CAN BE MADE TO SOUT WEST
CORNER.
SPACE ALLOCATIONS SHOULD BE AS FOLLOWS:
1. CENTER:GARBAGRIHA-COURTYARD WITH TULSI PLANT
2. NORTH EAST :SACRED PUJA ROOM
3. SOUTH WEST:DEDICATED TO ANCESTORS-IDEAL FOR MASTER BEDROOM
4. SOUTH EAST:KITCHEN WITH STORE FACING EAST
5. SOUTH:BEDROOM
6. EAST OR WEST:STAIRCASE
7. WEST:TOILET,STORES,ETC
8. EAST:BATHROOM
9. NORTH:TREASURY ROOM
27. VASTU NOTES:DOOR
AN EAST FACING DOOR:BRINGS FAME AND STRENGTH
A NORTH FACING DOOR:BRINGS CHILDREN AND CATTLE
A SOUTH FACING DOOR:BRINGS WEALTH AND FAME
A WEST FACING DOOR:BRINGS MISFORTUNE
MAIN DOOR FACING NORTH AND EAST IS BEST.
VASTU NOTES:ENTRANCE GATE
FOR A PLOT FACING NORTH SIDE ROAD,THE GATE SHOULD BE IN THE NORTH OR
NORTH EAST CORNER;
FOR A PLOT FACING EAST SIDE ROAD,THE GATE SHOULDBE IN THE EAST OR
NORTH EAST CORNER
FOR A PLOT FACING SOUTH SIDE ROAD,THE GATE SHOULD BE IN THE SOUTH OR
SOUTH EAST CORNER
FOR A PLOT FACING WEST SIDE ROAD .THE GATE SHOULD BE IN THE WEST OR
NORTH WEST CORNER.
28. VASTU NOTES:VENTILAATION,VERANDAH,WINDOW AND BALCONY
AYU OR WIND GUARDS THE N0RTH WEST DIRECTION
THESE FOUR THINGS SHOULD BE MADE IN THE NORTH WEST
BY DOING SO PEOPLE IN HOUSE WILL REMAIN HEALTHY
VASTU NOTES: WATER
WATER BODIES PRESIDE OVER NORTH OR EAST OR IN NORTH EAST DIRECTION
SWIMMING POOL SHOULD ALSO SHOULD BE IN EAST OR NORTH SIDE OF THE
HOUSE.
WATER SUPPLY IN THE HOUSE SHOULD BE FROM NORTH OR EAST.
SLOPE FOR RAINWATER PASSAGE SHOULD BE IN NORTH EAST DIRECTION AND
LET OUT FROM NORTH EAST SIDE
THE WATER FACILITY SHULD BE IN NORTH EAST DIRECTION ONLY.
29. VASTU NOTES:STAIRCASE
ORIENTATION OF STAIRCASE MUST ALWAYS MOVE CLOCKWISE WHILE
CLIMBING.
THE STAIRS SHOULD BE PROVIDED IN THE SOUTH, SOUTH-WEST OR WEST OF
THE BUILDING
SLOPE OF THE STAIRS SHOULD FACE EITHER EAST OR NORTH
STAIR NUMBERS SHOULD ALWAYS BE IN ODD NUMBERS.
VASTU NOTES:WORSHIP ROOM
WORSHIP ROOM SHOULD BE IN NORTH EAST,NORTH OR EAST DIRECTION AND
FACE OF GOD SHOULD BE FACING SOUTH OR WEST SO THATT WHILE
WORSHIPPING
WE FACE TOWARDS EAST OR NORTH
THIS WILL BRING PROSPERITY TO THE FAMILY.
30. VASTU NOTES:MASTER BEDROOM
LAND LORDS MAIN BEDROOM SHOULD BE IN SOUTH WEST DIRECTION
BED SHOULD BE ATTACHED TO THE WALLS OF THE SOUTH OR WEST SO THATT MORE
EMPTY SPACE IS LEFT IN NORTH EAST
BEDROOM SHOULD NOT BE IN NORTH EAST OR SOUTH EAST DIRECTION
PEOPLE SLEEPING IN THE NORTH EAST OR SOUTH EAST DIRECTIONS DO NOT ENJOY
SOUND SLEEP
IF THERE ARE TWO NEDROOM IN THE HOUSE,THEN ONE SHOULD BE IN THE SOUTH
WEST AND THE OTHER SHOULD BE IN THE NORTH WEST DIRECTION
BEDROOM IN EAST GIVES BAD HEALTH ,WHILE THE ONE IN THE SOUTH GIVES BETTER
HEALTH
A BEDROOM IN THE WEST IS CONSIDERED GOOD,WHILE A BEDROOM IN THE NORTH
IS BAD.
WHILE SLEEPING THE HEAD SHOULD BE IN THE TE SOUTH AND THE LEG IN THE
NORTH DIRECTION
HEAD OF MAN IS THE NORTH POLE AND LEG IS THE SOUTH POLE, SO THE BEDROOM
SHOULD BE IN THE SOUTH,SOUTH,WEST AND WEST CORNER.
31. VASTU NOTES:KITCHEN
IT SHOULD BE CONSTRUCTED IN SOUTH EAST CORNER ,LEAVING MORE SACE
TOWARDS EAST
IN ORDER TO HAVE THE ULTRAVOILET RAYS FROM THE SUN FOR A LONGER
PERIOD,AS THEY HAVE THE PROPERTY OF KEEPING FOOD STUFF SAFE FROM
HARMFUL ORGANISM.
VASTU NOTES:SITTING ROOM
IT IS THE HEART OF THE HOUSE
IT SHOULD BE IN WEST OR SOUTH WEST DIRECTION
THERE BY KEEPING THE NORTH AND EAST SIDES EMPTIER,SO THAT PEOPLE
SITING IN THE SOUH OR WEST CAN DACEEAST OR NORTH
THIS HELPS GIVE MORE LIGHT AND ALSO INDUCES POSITIVE THINKING
32. VASTU NOTES:SIUDY ROOM
IT SHOULD BE LOCATED IN NORTH EAST CORNER OF THE HOUSE WHICH IS ALSO
THE PLACE FOR WORSHIP ROOM
STUDY ROOM IS TREATED ON PAR WITH WORSHIP ROOM AND GIVEN EQUAL
IMPORTANCE
VASTU NOTES:BATHROOM
IDEAL PLACE FOR BATHROOM IS EASTERN SIDE,WHICH IS SCIENTIFICALLY
PROVEN TO KEEP BATHROOM DRY AND FUNGUS FREE.
NOWADAYS ,THE TOILET AND BATHROOM ARE COMBINED AND OFTEN
ATTACHED TO BEDROOM,THIS IS GAINING POPULARITY BECAUSE OF
COVINIENCE
IN SUCH CASE BATHROOM SHOULD NOT BE PLACED IN NORTH EAST
THE WATER PIPES ,SHOWER ,BATH TUB ETC SHOULD BE LACED IN THE NORTH
EAST ZONE OF THE THE BATHROOM
33. VASTU NOTES:SEPTIC TANK
ALWAYS MADE BEHIND TOILET AND BATHROOM AS IT IS VERY HEAVY.
BEST PALCE FOR SEPTIC TANK IS THE SOUTH
NO SEPTIC TANK SHOULD BE BUILT IN NORTH AND EAST DIRECTION BECAUSE
THESE DIRECTIONS ARE PLACE FOR PUJA OR WORSHIP.