User's manual SR609C                                                                          08.2008



                                          Contents

Contents----------------------------------------------------------------------------------1
1.     Safety information --------------------------------------------------------------2
1.1    Installation and commissioning -----------------------------------------------2
1.2    About this manual ----------------------------------------------------------------2
1.3    Liability waiver ---------------------------------------------------------------------3
1.4    Important remark-------------------------------------------------------------------3
1.5    Description of symbols-----------------------------------------------------------3
2.     Installation -------------------------------------------------------------------------4
2.1    Installing the controller ----------------------------------------------------------4
2.2    Power connection -----------------------------------------------------------------4
2.3    Terminal connection -------------------------------------------------------------6
3.     Function setting------------------------------------------------------------------8
3.1    Illustration of controller panel--------------------------------------------------8
3.2    Setting the time--------------------------------------------------------------------8
3.3    Manual heating -------------------------------------------------------------------9
3.4    Timing heating--------------------------------------------------------------------10
4.     Installation system diagram------------------------------------------------12
5.     Protection function -----------------------------------------------------------13
5.1    Memory protection--------------------------------------------------------------13
5.2    Screen protection --------------------------------------------------------------13
5.3    Trouble protection---------------------------------------------------------------13
6.     Quality guarantee -------------------------------------------------------------13
7.     Technical data------------------------------------------------------------------14
8.     Delivery scope-----------------------------------------------------------------14
9.     Device matchable to this controller ------------------------------------15


-------------------------------------------------------------------------------------------------------
                                                 -1-
User's manual SR609C                                                                           08.2008

1. Safety information


1.1 Installation and commissioning
 When laying cables, please ensure that no damage occurs to any of
    the constructional fire safety measures presented in the building.
 The controller can not be installed in rooms where easily inflammable
    gas mixtures are present or may occur.
 The permissible environmental conditions can not be exceeded at the
    site of installation.
 Before connecting the device, make sure that the energy supply
    matches the specifications that controller requires.
 All devices connected to the controller must conform to the technical
    specifications of the controller.
 All operations on an open regulator are only to be conducted cleared
    from the power supply. All safety regulations for working on the power
    supply are valid. Connecting and /or all operations that require opening
    the regulator (e.g. changing the fuse) are only to be conducted by
    specialists.


1.2 About this manual
This manual describes the installation, function and operation of a solar
thermal controller. When installing the remaining components e.g. the
solar collectors.and the storage unit, are sure to observe the appropriate
installation instructions provided by each manufacturer. Installation,
electrical connection, commissioning and maintenance of the device may
only be performed by trained professional personnel. The professional
personnel must be familiar with this manual and follow the instructions
contained herein.


-------------------------------------------------------------------------------------------------------
                                                 -2-
User's manual SR609C                                                                           08.2008



1.3 Liability waiver
The manufacturer cannot monitor the compliance with these instructions
or the circumstances and methods used for installation, operation,
utilization and maintenance of this controller. Improper installation can
cause damages to material and persons. This is the reason why we do
not take over responsibility and liability for losses, damages or cost that
might arise due to improper installation, operation or wrong utilization and
maintenance or that occurs in some connection with the aforementioned.
Moreover we do not take over liability for patent infringements or
infringements – occurring in connection with the use of this controller- on
third parties rights. The manufacturer preserves the right to put changes
to product, technical date or installation and operation instructions without
prior notice. As soon as it becomes evident that safe operation is no
longer possible (e.g. visible damage). Please immediately take the device
out of operation. Note: ensure that the device cannot be accidentally
placed into operation.
1.4 Important remark
We have carefully checked the text and pictures of this manual and
provided the best of our knowledge and ideas, however inevitable errors
maybe exist. Please note that we can not guarantee that this manual is
given in the integrity of image and text, they are just some examples, and
they apply only to our own system. Incorrect, incomplete and erroneous
information and the resulting damage we do not take responsibility.
1.5 Description of symbols
             Safety instruction:
             The safety instructions in the manual are marked with a warning
             triangle. It indicates measures, which can lead to personal injury
and safety risks.
-------------------------------------------------------------------------------------------------------
                                                 -3-
User's manual SR609C                                                                           08.2008

Operation steps: small triangle “►”is used to indicate operation step.
Notes: Contains important information about operation or function.
2.Installation
Controller can only be installed indoors, and is far away from dangerous
place and away from the electromagnetic field. Controller should be
equipped with an additional plug, which should have minimum 3mm
distance between the pole of the plug or effective compliance with the
provisions of the installation. For example, switch or fuse, please note
wires should be separated, and use the AC.



2.1 Installing the controller
Note: the controller can only be installed in an area having an adequate
level of protection.
►Choosing a suitable site
►Drilling the up fixing hole
►Screwing on the screw
►Taking away the cover plate
►Hanging the bottom plate on the fixing hole ①
►Marking the position of fixing hole ② & ③
►Taking away the bottom plate
►Drilling the hole ② & ③
►Rehanging the bottom plate on screw ①
►Fixing bottom plate with ② & ③ screw

2.2 Power connection
Power can only be switched on only when the housing of controller is
closed; an installer must make sure that the IP protection class of the
controller is not damaged during installation.


Depending on the type of installation, the cables may enter the device
-------------------------------------------------------------------------------------------------------
                                                 -4-
User's manual SR609C                                                                           08.2008

through the rear hole of the case ④or the lower side hole of the case ⑥


Cable come from the rear ④: remove the plastic flaps from the rear side
of the case using an appropriate tool.

Cable come from the below ⑥: Cut the left and right plastic flaps using an
appropriate tool (e.g. knife) and break them out of the case.

Notes: the flexible wire must be fastened to the case using the
strain-relief clamps provided




-------------------------------------------------------------------------------------------------------
                                                 -5-
User's manual SR609C                                                                           08.2008

2.3 Terminal connection
             Before to open the terminal, please be sure to switch-off the
             power supplier and pay attention to the local electricity supply
             rules.

 Terminal layout




FU1 is the fuse of controller, AC250V/0.5A
“Reset” button: This button is on the terminal connection panel, when
system program is out of working, press “Reset” to recover the program of
system to the factory settings.

 Power connection
Power connection terminals are 10A current, please sure to connect to
ground.

 Output ports
Electrical heater output H1: Electromagnetic relay, max. Switching
current 20A, for electrical heater

 input ports
Input port T1: for NTC10K, B=3950 sensor, for measuring the
temperature of tank.

 Advice regarding the installation of temperature sensor
-------------------------------------------------------------------------------------------------------
                                                 -6-
User's manual SR609C                                                                           08.2008



Only original factory equipped NTC10K,B=3950 temperature sensor are
approved for use with tank, it is equipped with 20m PVC cable, and they
                                                      o
are temperature resistant up to 105 C, not necessary to distinguish the
positive and negative polarity of the sensor connection.


All sensor cables carry low voltage, and it is necessary to take measures
to avoid inductive effects, so sensor cables should not be laid close to 230
volt or 400 volt cables (minimum separation of 100mm)


If external inductive effects are existed, e.g. from heavy current cables,
overhead train cables, transformer substations, radio and television
devices, amateur radio stations, microwave devices etc, then the cables
to the sensors must be adequately shielded.


Sensor cables may be extended to a maximum length of ca. 100 meter,
                                                                            2
when cable’s length is up to 50m, and then 0.75mm cable should be used.
                                                                            2
When cable’s length is up to 100m, and then 1.5mm cables should be
used.




-------------------------------------------------------------------------------------------------------
                                                 -7-
User's manual SR609C                                                                           08.2008

3. Function setting
             Connect the sensor, electrical heater to the controller before
             you connect the power supply!

After switching on power to the controller, firstly it will ask for to set the
time and set the parameter of system.

3.1 Illustration of controller panel




3.2 Setting time
►Press “Clock” button, time displays on the screen, hour selection area
“00” blinks on the screen.
►Press “▲▼” button to set hour of
clock
►Repress “Clock”, minute selection
area“00”blinks
► Press “▲▼” button to set minute of clock.
► After setting, press “Clock” to exit program, or waiting for 12 seconds,
controller exits automatically, the setup parameters are saved
automatically.

-------------------------------------------------------------------------------------------------------
                                                 -8-
User's manual SR609C                                                                           08.2008



3.3 Manual heating
Description:
Electrical heater can be integrated into solar system as back-up, and it
can be controlled by temperature, when controller checks the tank
temperature T1 is 3oC below the preset temperature, electrical heater will
be triggered. When tank temperature T1 reaches to the preset
temperature, electrical heater is ceased.


Condition for triggering heating: tank temperature is 3 oC below the the
preset temperature



Activate/deactivate this function:
► Press “manual” button, temperature
area “60oC” blinks on the screen.
► Press “▲▼” button to adjust the
switch-on temperature, adjustable
range: 30oC ~ 80oC, factory default: 60oC.
After 12 seconds, this heating function is activated,                                  heating signal
displays on the screen.
►Press “manual” button to switch-off manual heating function.


Note: manual heating can only heat tank one time, after manual heating is
triggered, when temperature of tank reaches to the setting temperature,
manual heating ceases, and manual heating function will be deactivated
automatically, if customer wants to heat again, you need redo according
to above steps.


-------------------------------------------------------------------------------------------------------
                                                 -9-
User's manual SR609C                                                                           08.2008

3.4 Timing heating
Function description:
Electrical heater can be integrated into solar system used as back-up of
system, and they can be triggered automatically at preset time by preset
temperature. Within a preset time sections, when the temperature (T1) of
tank drops below the preset switching-on temperature of this function,
back-up heating starts to work, when T1 rises up to the preset turning off
temperature, back-up heating is stopped. Within 24 hours, three time
sections can be set with this controller.


The adjustable range of switch-on temperature of heating is 30 oC ~
(OFF-3oC), the adjustable range of switch-off temperature (On+3oC) ~
80oC.


Setup steps:
►Press “SET” button for 3 seconds, to access the setting program, set
 the switch-on time of the first time section and its switch-on temperature,
 hour area blinks on the screen.
►Press “▲▼” button, to set hour of the swith-on time of heating
►Press “               ”button to transfer to minute area, minute blinks on the
screen
►Press “▲▼” button, to set minute
of the swith-on time of heating
►Press “             ” button to transfer
to temperature area, temperature
blinks on the screen,
►Press “▲▼” button, to set the swith-on temperature of heating
►Repress “SET” button, to access the setting program, set the switch-off
 time of the first time section and its switch-off temperature, hour area
-------------------------------------------------------------------------------------------------------
                                                - 10 -
User's manual SR609C                                                                           08.2008

 blinks on the screen.
►Press “▲▼” button, to set hour of the swith-off time of heating
►Press “               ”button to transfer to minute area, minute area blinks on
the screen
►Press “▲▼” button, to set minute
of the swith-off time of heating
►Press “             ” button to transfer to
temperature area, temperature
blinks on the screen,
►Press “▲▼” button, to set the swith-off temperature of heating
►Press “SET” button again, to access the setting program, set the
 switch-on time of the second time section and its switch-on temperature.
 Doling like above description, to set the second / third time section and
 its corresponding switch-on/ switch-off temperature.

If you want to shut off one timing heating, then you can set the turning on
time and turning off time same value ( for example, the second time
section no this function, then you can set turning on/off time is 10:00 ~
10:00)


         ① Heating signal displays on the screen, it indicates timing heating
is activated.


Note:
When time is outside of the preset time section, back-up heating doesn’t
work automatically even when the tank temperature reaches the switch
–on temperature of heating.
The time in this controlled is 24 hours, when you set time section, the
switch-off time of heating should be later than switch-on time. For

-------------------------------------------------------------------------------------------------------
                                                - 11 -
User's manual SR609C                                                                           08.2008

example: if you set the switch-on time of heating is at 17:00, but switch-off
time of heating is 6:00, then this setting doesn’t take effect, that means
within this time section, heating function doesn’t work.                           The correct set is
like flowing: it should be divided into two time sections, one time section is
from 17:00 to 23:59, the other time section is from 00:00 to 06:00.


When user selects electrical heater as back-up device, we recommend
using SR801 unit connecting controller and electrical heater. (Detailed
see )


4. Installation system diagram




-------------------------------------------------------------------------------------------------------
                                                - 12 -
User's manual SR609C                                                                           08.2008

5. Protection function


5.1. Memory protection
In case power failure occurs, controller keeps the parameter settings
unchanged.


5.2 Screen protection
When no any press on button for 3 minutes, screen protection is activated
automatically, and then LCD lighting lamp is switched-off. Through press
any button to light LCD lamp again.


5.3 Trouble protection
When temperature sensor’s (T1) wiring is interrupted, not connected or
short circuit, controller switchs off the corresponding signal output, and
simultaneousely “ E1” error code displays on the screen.


6. Quality Guarantee
Manufacturer provides following quality responsibilities to end users:
within the period of quality responsibilities, manufacturer will exclude the
failure caused by production and material selection. A correct installation
will not lead to failure. When a user takes incorrect handling way, incorrect
installation, improper or crud handling, wrong connection of sensor in
system and incorrect operation, the quality responsibility is invalid for
them.


The warrantee expires within 24 months after the date of purchasing the
controller.




-------------------------------------------------------------------------------------------------------
                                                - 13 -
User's manual SR609C                                                                           08.2008

7. Technical data
 Appearance of controller: see product itself ( dimension: 179mm
    x120mm x43mm)
 Power supply:AC230V ±10%
 Power consumption:< 3W
 Accuracy of temperature measuring: ± 2oC
 Range of tank temperature measuring: 0 ~100 oC
 Suitable power of electrical heater, ≤ 2000W
 Inputs: 1 piece NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC
    cable ≤105oC),
 Outputs:1 relay, for electrical heating
 Ambient temperature :-10oC ~ 50oC.
 Water proof grade:IP40.



8. Delivery scope
 Controller                                                                                   1 piece
 Power cable                                                                                  1 piece
 Customer manual                                                                              1 piece
 NTC10K sensor(size: φ6*50mm,cable length20 m)                                                1 pieces
 Plastic expansion screw                                                                      3 pieces
 Screw                                                                                        3 pieces
 Strain-relief clamp                                                                          4 pieces




-------------------------------------------------------------------------------------------------------
                                                - 14 -
User's manual SR609C                                                                           08.2008

9. Device matchable to this controller

 Contactor unit of high power: SR801
 When user selects electrical heater as
back-up device, we recommend using SR801
unit    connecting          controller       and      electrical
heater.


Technical data of SR801:
Dimension: 250mmx185mmx130mm
Power supply:AC230V ±10%
Suitable power: ≤ 6000W
                                                           o
Available ambient temperature: -10 ~ 50 C
Water proof grade: IP41




-------------------------------------------------------------------------------------------------------
                                                - 15 -

More Related Content

What's hot

Ficha de segurança maquinas
Ficha de segurança   maquinasFicha de segurança   maquinas
Ficha de segurança maquinas10345934
 
Sdmo mics-nexys-control panel-manual
Sdmo mics-nexys-control panel-manualSdmo mics-nexys-control panel-manual
Sdmo mics-nexys-control panel-manualCarlos Callirgos
 
Gebruikershandleiding telys 2 besturing 33502019901 0 1
Gebruikershandleiding telys 2 besturing 33502019901 0 1Gebruikershandleiding telys 2 besturing 33502019901 0 1
Gebruikershandleiding telys 2 besturing 33502019901 0 1andescar
 
Cdvr service manual renr7941-00 _ sis - caterpillar
Cdvr   service manual   renr7941-00 _ sis - caterpillarCdvr   service manual   renr7941-00 _ sis - caterpillar
Cdvr service manual renr7941-00 _ sis - caterpillarOtorongosabroso
 
Copia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptx
Copia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptxCopia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptx
Copia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptxAdemilson Coutinho
 
Apt analise preliminar de tarefa
Apt   analise preliminar de tarefaApt   analise preliminar de tarefa
Apt analise preliminar de tarefaHumberto Junior
 
Apt industrial-23-atividade-caminhao-munck
Apt industrial-23-atividade-caminhao-munckApt industrial-23-atividade-caminhao-munck
Apt industrial-23-atividade-caminhao-munckwaltermoreira
 
Compair cyclon-3 air compressor user manual-parts supplier
Compair cyclon-3 air compressor user manual-parts supplierCompair cyclon-3 air compressor user manual-parts supplier
Compair cyclon-3 air compressor user manual-parts supplierdaisy Airmax
 
Teletender skytrak model 5030 6034 parts
Teletender skytrak model 5030 6034 partsTeletender skytrak model 5030 6034 parts
Teletender skytrak model 5030 6034 partsSilvio roman
 
Mitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UP
Mitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UPMitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UP
Mitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UPjfjksmemmd
 
Siemens micromaster-440-manual
Siemens micromaster-440-manualSiemens micromaster-440-manual
Siemens micromaster-440-manualAshok Kumar
 
Apreciação riscos-nr-12
Apreciação riscos-nr-12Apreciação riscos-nr-12
Apreciação riscos-nr-12Xaropada
 

What's hot (20)

Crane handbook
Crane handbookCrane handbook
Crane handbook
 
final (Approved Thesis) do this for ur fyp
final (Approved Thesis) do this for ur fypfinal (Approved Thesis) do this for ur fyp
final (Approved Thesis) do this for ur fyp
 
Ficha de segurança maquinas
Ficha de segurança   maquinasFicha de segurança   maquinas
Ficha de segurança maquinas
 
Trabalho em Altura
Trabalho em AlturaTrabalho em Altura
Trabalho em Altura
 
Sdmo mics-nexys-control panel-manual
Sdmo mics-nexys-control panel-manualSdmo mics-nexys-control panel-manual
Sdmo mics-nexys-control panel-manual
 
Gebruikershandleiding telys 2 besturing 33502019901 0 1
Gebruikershandleiding telys 2 besturing 33502019901 0 1Gebruikershandleiding telys 2 besturing 33502019901 0 1
Gebruikershandleiding telys 2 besturing 33502019901 0 1
 
9. power window
9. power window9. power window
9. power window
 
Cdvr service manual renr7941-00 _ sis - caterpillar
Cdvr   service manual   renr7941-00 _ sis - caterpillarCdvr   service manual   renr7941-00 _ sis - caterpillar
Cdvr service manual renr7941-00 _ sis - caterpillar
 
Copia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptx
Copia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptxCopia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptx
Copia_de_Apresentacao_-_PEMT-_TRAINER_2022.pptx
 
TREINAMENTO PARA TRABALHADOR PORTUARIO
TREINAMENTO PARA TRABALHADOR PORTUARIOTREINAMENTO PARA TRABALHADOR PORTUARIO
TREINAMENTO PARA TRABALHADOR PORTUARIO
 
Apt analise preliminar de tarefa
Apt   analise preliminar de tarefaApt   analise preliminar de tarefa
Apt analise preliminar de tarefa
 
LITAR GELANG (RING)
LITAR GELANG (RING)LITAR GELANG (RING)
LITAR GELANG (RING)
 
Apt industrial-23-atividade-caminhao-munck
Apt industrial-23-atividade-caminhao-munckApt industrial-23-atividade-caminhao-munck
Apt industrial-23-atividade-caminhao-munck
 
Compair cyclon-3 air compressor user manual-parts supplier
Compair cyclon-3 air compressor user manual-parts supplierCompair cyclon-3 air compressor user manual-parts supplier
Compair cyclon-3 air compressor user manual-parts supplier
 
Teletender skytrak model 5030 6034 parts
Teletender skytrak model 5030 6034 partsTeletender skytrak model 5030 6034 parts
Teletender skytrak model 5030 6034 parts
 
M1 s2 SMET
M1 s2 SMETM1 s2 SMET
M1 s2 SMET
 
Mitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UP
Mitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UPMitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UP
Mitsubishi FD50K Forklift Trucks Service Repair Manual SN:F28B-50001-UP
 
Siemens micromaster-440-manual
Siemens micromaster-440-manualSiemens micromaster-440-manual
Siemens micromaster-440-manual
 
Apreciação riscos-nr-12
Apreciação riscos-nr-12Apreciação riscos-nr-12
Apreciação riscos-nr-12
 
Andaimes e Balancim.ppt
Andaimes e Balancim.pptAndaimes e Balancim.ppt
Andaimes e Balancim.ppt
 

Similar to SR609C User Manual: Installation and Operation Guide

DSIDS User manual for ds product (ver1.3)
DSIDS User manual for ds product (ver1.3)DSIDS User manual for ds product (ver1.3)
DSIDS User manual for ds product (ver1.3)Thanh Hưng Nguyễn
 
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_cCataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_cDien Ha The
 
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_cCataloge ge 3.control and_automation-01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_cDien Ha The
 
Applied motion products ssm brochure
Applied motion products ssm brochureApplied motion products ssm brochure
Applied motion products ssm brochureElectromate
 
Fx3 g,fx3u,fx3uc series users manual positioning control edition
Fx3 g,fx3u,fx3uc series users manual   positioning control editionFx3 g,fx3u,fx3uc series users manual   positioning control edition
Fx3 g,fx3u,fx3uc series users manual positioning control editionphong279
 
Fanuc 0i maintenance manual CNC milling machine
Fanuc 0i maintenance manual CNC milling machineFanuc 0i maintenance manual CNC milling machine
Fanuc 0i maintenance manual CNC milling machineCNCDATAN
 
GM PaxGo Series Bagging Scale 25kg.pdf
GM PaxGo Series Bagging Scale 25kg.pdfGM PaxGo Series Bagging Scale 25kg.pdf
GM PaxGo Series Bagging Scale 25kg.pdfGeneral Measure
 
Hyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualHyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualfhsjekkdkem
 
Hyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualHyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualidkkdmmdd
 
Hyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualHyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualfhsejkdkmem
 

Similar to SR609C User Manual: Installation and Operation Guide (20)

Sr208 c manual+ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-wo...
Sr208 c manual+ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-wo...Sr208 c manual+ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-wo...
Sr208 c manual+ultisolar-new-energy-co-ltd-solar-water-heaters-controllers-wo...
 
SR868C8-EN-20110303+Ultisolar New Energy Co Ltd Solar Pump Station Solar Wate...
SR868C8-EN-20110303+Ultisolar New Energy Co Ltd Solar Pump Station Solar Wate...SR868C8-EN-20110303+Ultisolar New Energy Co Ltd Solar Pump Station Solar Wate...
SR868C8-EN-20110303+Ultisolar New Energy Co Ltd Solar Pump Station Solar Wate...
 
Sr530 c8+ultisolar new energy co ltd solar pump station solar water heater co...
Sr530 c8+ultisolar new energy co ltd solar pump station solar water heater co...Sr530 c8+ultisolar new energy co ltd solar pump station solar water heater co...
Sr530 c8+ultisolar new energy co ltd solar pump station solar water heater co...
 
Sr961 962+ultisolar new energy co ltd solar pump station solar water heater c...
Sr961 962+ultisolar new energy co ltd solar pump station solar water heater c...Sr961 962+ultisolar new energy co ltd solar pump station solar water heater c...
Sr961 962+ultisolar new energy co ltd solar pump station solar water heater c...
 
Sr971 972+ultisolar new energy co ltd solar pump station solar water heater c...
Sr971 972+ultisolar new energy co ltd solar pump station solar water heater c...Sr971 972+ultisolar new energy co ltd solar pump station solar water heater c...
Sr971 972+ultisolar new energy co ltd solar pump station solar water heater c...
 
SR1068 Solar Water Heater Controller
SR1068 Solar Water Heater ControllerSR1068 Solar Water Heater Controller
SR1068 Solar Water Heater Controller
 
Sr500 en ultisolar new energy solar pump station solar water heater controlle...
Sr500 en ultisolar new energy solar pump station solar water heater controlle...Sr500 en ultisolar new energy solar pump station solar water heater controlle...
Sr500 en ultisolar new energy solar pump station solar water heater controlle...
 
SR601En Solar Water Heater Controller for Compact Non-pressure System
SR601En Solar Water Heater Controller for Compact Non-pressure SystemSR601En Solar Water Heater Controller for Compact Non-pressure System
SR601En Solar Water Heater Controller for Compact Non-pressure System
 
DSIDS User manual for ds product (ver1.3)
DSIDS User manual for ds product (ver1.3)DSIDS User manual for ds product (ver1.3)
DSIDS User manual for ds product (ver1.3)
 
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_cCataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation_dienhathe.com-4_01_vat300_e_title_rev_c
 
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_cCataloge ge 3.control and_automation-01_vat300_e_title_rev_c
Cataloge ge 3.control and_automation-01_vat300_e_title_rev_c
 
GP2000E.pdf
GP2000E.pdfGP2000E.pdf
GP2000E.pdf
 
Sa ak280-panasonic
Sa ak280-panasonicSa ak280-panasonic
Sa ak280-panasonic
 
Applied motion products ssm brochure
Applied motion products ssm brochureApplied motion products ssm brochure
Applied motion products ssm brochure
 
Fx3 g,fx3u,fx3uc series users manual positioning control edition
Fx3 g,fx3u,fx3uc series users manual   positioning control editionFx3 g,fx3u,fx3uc series users manual   positioning control edition
Fx3 g,fx3u,fx3uc series users manual positioning control edition
 
Fanuc 0i maintenance manual CNC milling machine
Fanuc 0i maintenance manual CNC milling machineFanuc 0i maintenance manual CNC milling machine
Fanuc 0i maintenance manual CNC milling machine
 
GM PaxGo Series Bagging Scale 25kg.pdf
GM PaxGo Series Bagging Scale 25kg.pdfGM PaxGo Series Bagging Scale 25kg.pdf
GM PaxGo Series Bagging Scale 25kg.pdf
 
Hyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualHyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manual
 
Hyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualHyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manual
 
Hyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manualHyundai r80 7 crawler excavator service repair manual
Hyundai r80 7 crawler excavator service repair manual
 

More from Shandong iSentrol Electronic Technology Co., Ltd

More from Shandong iSentrol Electronic Technology Co., Ltd (20)

US211M digital flow meter user manual
US211M digital flow meter user manualUS211M digital flow meter user manual
US211M digital flow meter user manual
 
Ce Report of usc-hs21ti hall water flow sensor from iSentrol
Ce Report of usc-hs21ti hall water flow sensor from iSentrolCe Report of usc-hs21ti hall water flow sensor from iSentrol
Ce Report of usc-hs21ti hall water flow sensor from iSentrol
 
Ultisolar SR81Q Solar Controller Manual
Ultisolar SR81Q Solar Controller ManualUltisolar SR81Q Solar Controller Manual
Ultisolar SR81Q Solar Controller Manual
 
Ultisolar SR1568 Most Powerful Solar Thermal Controller Wifi Featured
Ultisolar SR1568 Most Powerful Solar Thermal Controller Wifi FeaturedUltisolar SR1568 Most Powerful Solar Thermal Controller Wifi Featured
Ultisolar SR1568 Most Powerful Solar Thermal Controller Wifi Featured
 
Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System
Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System
Ultisolar SR81 Solar Thermal Controller for Split Solar Water Heating System
 
Ultisolar SR658 Solar Controller for Split Hot water system
Ultisolar SR658 Solar Controller for Split Hot water systemUltisolar SR658 Solar Controller for Split Hot water system
Ultisolar SR658 Solar Controller for Split Hot water system
 
Ultisolar SR288 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR288 Split Solar Thermal System Controller Wifi FeaturedUltisolar SR288 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR288 Split Solar Thermal System Controller Wifi Featured
 
Ultisolar SR258 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR258 Split Solar Thermal System Controller Wifi FeaturedUltisolar SR258 Split Solar Thermal System Controller Wifi Featured
Ultisolar SR258 Split Solar Thermal System Controller Wifi Featured
 
SP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New ManualSP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New Manual
 
US211M定量控制仪产品使用说明书
US211M定量控制仪产品使用说明书US211M定量控制仪产品使用说明书
US211M定量控制仪产品使用说明书
 
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
Etracer6415BND Etracer4415BND user manual by Ultisolar New Energy
 
US211M Quantitative Controller and Flow Rate Display User Manual
US211M Quantitative Controller and Flow Rate Display User ManualUS211M Quantitative Controller and Flow Rate Display User Manual
US211M Quantitative Controller and Flow Rate Display User Manual
 
SPP-01 Super Parameter Programmer User Manual Ultisolar New Energy
SPP-01 Super Parameter Programmer User Manual Ultisolar New EnergySPP-01 Super Parameter Programmer User Manual Ultisolar New Energy
SPP-01 Super Parameter Programmer User Manual Ultisolar New Energy
 
SR805W Wireless Remote Controller User Manual
SR805W Wireless Remote Controller User ManualSR805W Wireless Remote Controller User Manual
SR805W Wireless Remote Controller User Manual
 
SR805 Remote Controller User Manual
SR805 Remote Controller User ManualSR805 Remote Controller User Manual
SR805 Remote Controller User Manual
 
Ultisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User Manual
Ultisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User ManualUltisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User Manual
Ultisolar VS2048BN-VS3048BN-VS4548BN-VS6048BN User Manual
 
Ultisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User Manual
Ultisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User ManualUltisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User Manual
Ultisolar VS1024BN-VS2024BN-VS3024BN-VS4524BN-VS6024BN User Manual
 
Ultisolar iT3415 iT4415 iT6415 iTracer User Manual
Ultisolar iT3415 iT4415 iT6415  iTracer User ManualUltisolar iT3415 iT4415 iT6415  iTracer User Manual
Ultisolar iT3415 iT4415 iT6415 iTracer User Manual
 
Ultisolar LS1024BP LS2024BP Solar Controller user manual
Ultisolar  LS1024BP LS2024BP Solar Controller user manualUltisolar  LS1024BP LS2024BP Solar Controller user manual
Ultisolar LS1024BP LS2024BP Solar Controller user manual
 
SR528Q Wireless Solar Controller for Split Solar Water Heating System
SR528Q Wireless Solar Controller for Split Solar Water Heating SystemSR528Q Wireless Solar Controller for Split Solar Water Heating System
SR528Q Wireless Solar Controller for Split Solar Water Heating System
 

Recently uploaded

Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadAyesha Khan
 
Investment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy CheruiyotInvestment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy Cheruiyotictsugar
 
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...lizamodels9
 
Annual General Meeting Presentation Slides
Annual General Meeting Presentation SlidesAnnual General Meeting Presentation Slides
Annual General Meeting Presentation SlidesKeppelCorporation
 
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCRashishs7044
 
Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Kirill Klimov
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607dollysharma2066
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis UsageNeil Kimberley
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Seta Wicaksana
 
India Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample ReportIndia Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample ReportMintel Group
 
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCRashishs7044
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCRashishs7044
 
Market Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 EditionMarket Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 EditionMintel Group
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Timedelhimodelshub1
 
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCRashishs7044
 
8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCR8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCRashishs7044
 

Recently uploaded (20)

Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in IslamabadIslamabad Escorts | Call 03274100048 | Escort Service in Islamabad
Islamabad Escorts | Call 03274100048 | Escort Service in Islamabad
 
Investment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy CheruiyotInvestment in The Coconut Industry by Nancy Cheruiyot
Investment in The Coconut Industry by Nancy Cheruiyot
 
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
Call Girls In Connaught Place Delhi ❤️88604**77959_Russian 100% Genuine Escor...
 
Corporate Profile 47Billion Information Technology
Corporate Profile 47Billion Information TechnologyCorporate Profile 47Billion Information Technology
Corporate Profile 47Billion Information Technology
 
Annual General Meeting Presentation Slides
Annual General Meeting Presentation SlidesAnnual General Meeting Presentation Slides
Annual General Meeting Presentation Slides
 
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR8447779800, Low rate Call girls in Tughlakabad Delhi NCR
8447779800, Low rate Call girls in Tughlakabad Delhi NCR
 
Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024
 
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
(Best) ENJOY Call Girls in Faridabad Ex | 8377087607
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...
 
India Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample ReportIndia Consumer 2024 Redacted Sample Report
India Consumer 2024 Redacted Sample Report
 
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
8447779800, Low rate Call girls in Uttam Nagar Delhi NCR
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
8447779800, Low rate Call girls in Shivaji Enclave Delhi NCR
 
Market Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 EditionMarket Sizes Sample Report - 2024 Edition
Market Sizes Sample Report - 2024 Edition
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Time
 
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
8447779800, Low rate Call girls in Kotla Mubarakpur Delhi NCR
 
8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCR8447779800, Low rate Call girls in Saket Delhi NCR
8447779800, Low rate Call girls in Saket Delhi NCR
 

SR609C User Manual: Installation and Operation Guide

  • 1.
  • 2. User's manual SR609C 08.2008 Contents Contents----------------------------------------------------------------------------------1 1. Safety information --------------------------------------------------------------2 1.1 Installation and commissioning -----------------------------------------------2 1.2 About this manual ----------------------------------------------------------------2 1.3 Liability waiver ---------------------------------------------------------------------3 1.4 Important remark-------------------------------------------------------------------3 1.5 Description of symbols-----------------------------------------------------------3 2. Installation -------------------------------------------------------------------------4 2.1 Installing the controller ----------------------------------------------------------4 2.2 Power connection -----------------------------------------------------------------4 2.3 Terminal connection -------------------------------------------------------------6 3. Function setting------------------------------------------------------------------8 3.1 Illustration of controller panel--------------------------------------------------8 3.2 Setting the time--------------------------------------------------------------------8 3.3 Manual heating -------------------------------------------------------------------9 3.4 Timing heating--------------------------------------------------------------------10 4. Installation system diagram------------------------------------------------12 5. Protection function -----------------------------------------------------------13 5.1 Memory protection--------------------------------------------------------------13 5.2 Screen protection --------------------------------------------------------------13 5.3 Trouble protection---------------------------------------------------------------13 6. Quality guarantee -------------------------------------------------------------13 7. Technical data------------------------------------------------------------------14 8. Delivery scope-----------------------------------------------------------------14 9. Device matchable to this controller ------------------------------------15 ------------------------------------------------------------------------------------------------------- -1-
  • 3. User's manual SR609C 08.2008 1. Safety information 1.1 Installation and commissioning  When laying cables, please ensure that no damage occurs to any of the constructional fire safety measures presented in the building.  The controller can not be installed in rooms where easily inflammable gas mixtures are present or may occur.  The permissible environmental conditions can not be exceeded at the site of installation.  Before connecting the device, make sure that the energy supply matches the specifications that controller requires.  All devices connected to the controller must conform to the technical specifications of the controller.  All operations on an open regulator are only to be conducted cleared from the power supply. All safety regulations for working on the power supply are valid. Connecting and /or all operations that require opening the regulator (e.g. changing the fuse) are only to be conducted by specialists. 1.2 About this manual This manual describes the installation, function and operation of a solar thermal controller. When installing the remaining components e.g. the solar collectors.and the storage unit, are sure to observe the appropriate installation instructions provided by each manufacturer. Installation, electrical connection, commissioning and maintenance of the device may only be performed by trained professional personnel. The professional personnel must be familiar with this manual and follow the instructions contained herein. ------------------------------------------------------------------------------------------------------- -2-
  • 4. User's manual SR609C 08.2008 1.3 Liability waiver The manufacturer cannot monitor the compliance with these instructions or the circumstances and methods used for installation, operation, utilization and maintenance of this controller. Improper installation can cause damages to material and persons. This is the reason why we do not take over responsibility and liability for losses, damages or cost that might arise due to improper installation, operation or wrong utilization and maintenance or that occurs in some connection with the aforementioned. Moreover we do not take over liability for patent infringements or infringements – occurring in connection with the use of this controller- on third parties rights. The manufacturer preserves the right to put changes to product, technical date or installation and operation instructions without prior notice. As soon as it becomes evident that safe operation is no longer possible (e.g. visible damage). Please immediately take the device out of operation. Note: ensure that the device cannot be accidentally placed into operation. 1.4 Important remark We have carefully checked the text and pictures of this manual and provided the best of our knowledge and ideas, however inevitable errors maybe exist. Please note that we can not guarantee that this manual is given in the integrity of image and text, they are just some examples, and they apply only to our own system. Incorrect, incomplete and erroneous information and the resulting damage we do not take responsibility. 1.5 Description of symbols Safety instruction: The safety instructions in the manual are marked with a warning triangle. It indicates measures, which can lead to personal injury and safety risks. ------------------------------------------------------------------------------------------------------- -3-
  • 5. User's manual SR609C 08.2008 Operation steps: small triangle “►”is used to indicate operation step. Notes: Contains important information about operation or function. 2.Installation Controller can only be installed indoors, and is far away from dangerous place and away from the electromagnetic field. Controller should be equipped with an additional plug, which should have minimum 3mm distance between the pole of the plug or effective compliance with the provisions of the installation. For example, switch or fuse, please note wires should be separated, and use the AC. 2.1 Installing the controller Note: the controller can only be installed in an area having an adequate level of protection. ►Choosing a suitable site ►Drilling the up fixing hole ►Screwing on the screw ►Taking away the cover plate ►Hanging the bottom plate on the fixing hole ① ►Marking the position of fixing hole ② & ③ ►Taking away the bottom plate ►Drilling the hole ② & ③ ►Rehanging the bottom plate on screw ① ►Fixing bottom plate with ② & ③ screw 2.2 Power connection Power can only be switched on only when the housing of controller is closed; an installer must make sure that the IP protection class of the controller is not damaged during installation. Depending on the type of installation, the cables may enter the device ------------------------------------------------------------------------------------------------------- -4-
  • 6. User's manual SR609C 08.2008 through the rear hole of the case ④or the lower side hole of the case ⑥ Cable come from the rear ④: remove the plastic flaps from the rear side of the case using an appropriate tool. Cable come from the below ⑥: Cut the left and right plastic flaps using an appropriate tool (e.g. knife) and break them out of the case. Notes: the flexible wire must be fastened to the case using the strain-relief clamps provided ------------------------------------------------------------------------------------------------------- -5-
  • 7. User's manual SR609C 08.2008 2.3 Terminal connection Before to open the terminal, please be sure to switch-off the power supplier and pay attention to the local electricity supply rules.  Terminal layout FU1 is the fuse of controller, AC250V/0.5A “Reset” button: This button is on the terminal connection panel, when system program is out of working, press “Reset” to recover the program of system to the factory settings.  Power connection Power connection terminals are 10A current, please sure to connect to ground.  Output ports Electrical heater output H1: Electromagnetic relay, max. Switching current 20A, for electrical heater  input ports Input port T1: for NTC10K, B=3950 sensor, for measuring the temperature of tank.  Advice regarding the installation of temperature sensor ------------------------------------------------------------------------------------------------------- -6-
  • 8. User's manual SR609C 08.2008 Only original factory equipped NTC10K,B=3950 temperature sensor are approved for use with tank, it is equipped with 20m PVC cable, and they o are temperature resistant up to 105 C, not necessary to distinguish the positive and negative polarity of the sensor connection. All sensor cables carry low voltage, and it is necessary to take measures to avoid inductive effects, so sensor cables should not be laid close to 230 volt or 400 volt cables (minimum separation of 100mm) If external inductive effects are existed, e.g. from heavy current cables, overhead train cables, transformer substations, radio and television devices, amateur radio stations, microwave devices etc, then the cables to the sensors must be adequately shielded. Sensor cables may be extended to a maximum length of ca. 100 meter, 2 when cable’s length is up to 50m, and then 0.75mm cable should be used. 2 When cable’s length is up to 100m, and then 1.5mm cables should be used. ------------------------------------------------------------------------------------------------------- -7-
  • 9. User's manual SR609C 08.2008 3. Function setting Connect the sensor, electrical heater to the controller before you connect the power supply! After switching on power to the controller, firstly it will ask for to set the time and set the parameter of system. 3.1 Illustration of controller panel 3.2 Setting time ►Press “Clock” button, time displays on the screen, hour selection area “00” blinks on the screen. ►Press “▲▼” button to set hour of clock ►Repress “Clock”, minute selection area“00”blinks ► Press “▲▼” button to set minute of clock. ► After setting, press “Clock” to exit program, or waiting for 12 seconds, controller exits automatically, the setup parameters are saved automatically. ------------------------------------------------------------------------------------------------------- -8-
  • 10. User's manual SR609C 08.2008 3.3 Manual heating Description: Electrical heater can be integrated into solar system as back-up, and it can be controlled by temperature, when controller checks the tank temperature T1 is 3oC below the preset temperature, electrical heater will be triggered. When tank temperature T1 reaches to the preset temperature, electrical heater is ceased. Condition for triggering heating: tank temperature is 3 oC below the the preset temperature Activate/deactivate this function: ► Press “manual” button, temperature area “60oC” blinks on the screen. ► Press “▲▼” button to adjust the switch-on temperature, adjustable range: 30oC ~ 80oC, factory default: 60oC. After 12 seconds, this heating function is activated, heating signal displays on the screen. ►Press “manual” button to switch-off manual heating function. Note: manual heating can only heat tank one time, after manual heating is triggered, when temperature of tank reaches to the setting temperature, manual heating ceases, and manual heating function will be deactivated automatically, if customer wants to heat again, you need redo according to above steps. ------------------------------------------------------------------------------------------------------- -9-
  • 11. User's manual SR609C 08.2008 3.4 Timing heating Function description: Electrical heater can be integrated into solar system used as back-up of system, and they can be triggered automatically at preset time by preset temperature. Within a preset time sections, when the temperature (T1) of tank drops below the preset switching-on temperature of this function, back-up heating starts to work, when T1 rises up to the preset turning off temperature, back-up heating is stopped. Within 24 hours, three time sections can be set with this controller. The adjustable range of switch-on temperature of heating is 30 oC ~ (OFF-3oC), the adjustable range of switch-off temperature (On+3oC) ~ 80oC. Setup steps: ►Press “SET” button for 3 seconds, to access the setting program, set the switch-on time of the first time section and its switch-on temperature, hour area blinks on the screen. ►Press “▲▼” button, to set hour of the swith-on time of heating ►Press “ ”button to transfer to minute area, minute blinks on the screen ►Press “▲▼” button, to set minute of the swith-on time of heating ►Press “ ” button to transfer to temperature area, temperature blinks on the screen, ►Press “▲▼” button, to set the swith-on temperature of heating ►Repress “SET” button, to access the setting program, set the switch-off time of the first time section and its switch-off temperature, hour area ------------------------------------------------------------------------------------------------------- - 10 -
  • 12. User's manual SR609C 08.2008 blinks on the screen. ►Press “▲▼” button, to set hour of the swith-off time of heating ►Press “ ”button to transfer to minute area, minute area blinks on the screen ►Press “▲▼” button, to set minute of the swith-off time of heating ►Press “ ” button to transfer to temperature area, temperature blinks on the screen, ►Press “▲▼” button, to set the swith-off temperature of heating ►Press “SET” button again, to access the setting program, set the switch-on time of the second time section and its switch-on temperature. Doling like above description, to set the second / third time section and its corresponding switch-on/ switch-off temperature. If you want to shut off one timing heating, then you can set the turning on time and turning off time same value ( for example, the second time section no this function, then you can set turning on/off time is 10:00 ~ 10:00) ① Heating signal displays on the screen, it indicates timing heating is activated. Note: When time is outside of the preset time section, back-up heating doesn’t work automatically even when the tank temperature reaches the switch –on temperature of heating. The time in this controlled is 24 hours, when you set time section, the switch-off time of heating should be later than switch-on time. For ------------------------------------------------------------------------------------------------------- - 11 -
  • 13. User's manual SR609C 08.2008 example: if you set the switch-on time of heating is at 17:00, but switch-off time of heating is 6:00, then this setting doesn’t take effect, that means within this time section, heating function doesn’t work. The correct set is like flowing: it should be divided into two time sections, one time section is from 17:00 to 23:59, the other time section is from 00:00 to 06:00. When user selects electrical heater as back-up device, we recommend using SR801 unit connecting controller and electrical heater. (Detailed see ) 4. Installation system diagram ------------------------------------------------------------------------------------------------------- - 12 -
  • 14. User's manual SR609C 08.2008 5. Protection function 5.1. Memory protection In case power failure occurs, controller keeps the parameter settings unchanged. 5.2 Screen protection When no any press on button for 3 minutes, screen protection is activated automatically, and then LCD lighting lamp is switched-off. Through press any button to light LCD lamp again. 5.3 Trouble protection When temperature sensor’s (T1) wiring is interrupted, not connected or short circuit, controller switchs off the corresponding signal output, and simultaneousely “ E1” error code displays on the screen. 6. Quality Guarantee Manufacturer provides following quality responsibilities to end users: within the period of quality responsibilities, manufacturer will exclude the failure caused by production and material selection. A correct installation will not lead to failure. When a user takes incorrect handling way, incorrect installation, improper or crud handling, wrong connection of sensor in system and incorrect operation, the quality responsibility is invalid for them. The warrantee expires within 24 months after the date of purchasing the controller. ------------------------------------------------------------------------------------------------------- - 13 -
  • 15. User's manual SR609C 08.2008 7. Technical data  Appearance of controller: see product itself ( dimension: 179mm x120mm x43mm)  Power supply:AC230V ±10%  Power consumption:< 3W  Accuracy of temperature measuring: ± 2oC  Range of tank temperature measuring: 0 ~100 oC  Suitable power of electrical heater, ≤ 2000W  Inputs: 1 piece NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),  Outputs:1 relay, for electrical heating  Ambient temperature :-10oC ~ 50oC.  Water proof grade:IP40. 8. Delivery scope  Controller 1 piece  Power cable 1 piece  Customer manual 1 piece  NTC10K sensor(size: φ6*50mm,cable length20 m) 1 pieces  Plastic expansion screw 3 pieces  Screw 3 pieces  Strain-relief clamp 4 pieces ------------------------------------------------------------------------------------------------------- - 14 -
  • 16. User's manual SR609C 08.2008 9. Device matchable to this controller  Contactor unit of high power: SR801 When user selects electrical heater as back-up device, we recommend using SR801 unit connecting controller and electrical heater. Technical data of SR801: Dimension: 250mmx185mmx130mm Power supply:AC230V ±10% Suitable power: ≤ 6000W o Available ambient temperature: -10 ~ 50 C Water proof grade: IP41 ------------------------------------------------------------------------------------------------------- - 15 -