This document provides specifications for a 2.5G 1490nm 40km SFP transceiver made by Guilin GLsun Science and Tech Group Co., LTD. The transceiver operates at 2.5Gbps over single mode fiber for up to 40km, uses a 1490nm CWDM laser transmitter and photo detector, and complies with relevant SFP standards. It has applications in SDH, SONET, WDM and other optical transmission systems. The document provides detailed optical, electrical and mechanical specifications as well as ordering information for commercial and industrial temperature rated options.
Accelerate your Kubernetes clusters with Varnish CachingThijs Feryn
A presentation about the usage and availability of Varnish on Kubernetes. This talk explores the capabilities of Varnish caching and shows how to use the Varnish Helm chart to deploy it to Kubernetes.
This presentation was delivered at K8SUG Singapore. See https://feryn.eu/presentations/accelerate-your-kubernetes-clusters-with-varnish-caching-k8sug-singapore-28-2024 for more details.
UiPath Test Automation using UiPath Test Suite series, part 4DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 4. In this session, we will cover Test Manager overview along with SAP heatmap.
The UiPath Test Manager overview with SAP heatmap webinar offers a concise yet comprehensive exploration of the role of a Test Manager within SAP environments, coupled with the utilization of heatmaps for effective testing strategies.
Participants will gain insights into the responsibilities, challenges, and best practices associated with test management in SAP projects. Additionally, the webinar delves into the significance of heatmaps as a visual aid for identifying testing priorities, areas of risk, and resource allocation within SAP landscapes. Through this session, attendees can expect to enhance their understanding of test management principles while learning practical approaches to optimize testing processes in SAP environments using heatmap visualization techniques
What will you get from this session?
1. Insights into SAP testing best practices
2. Heatmap utilization for testing
3. Optimization of testing processes
4. Demo
Topics covered:
Execution from the test manager
Orchestrator execution result
Defect reporting
SAP heatmap example with demo
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
Smart TV Buyer Insights Survey 2024 by 91mobiles.pdf91mobiles
91mobiles recently conducted a Smart TV Buyer Insights Survey in which we asked over 3,000 respondents about the TV they own, aspects they look at on a new TV, and their TV buying preferences.
Epistemic Interaction - tuning interfaces to provide information for AI supportAlan Dix
Paper presented at SYNERGY workshop at AVI 2024, Genoa, Italy. 3rd June 2024
https://alandix.com/academic/papers/synergy2024-epistemic/
As machine learning integrates deeper into human-computer interactions, the concept of epistemic interaction emerges, aiming to refine these interactions to enhance system adaptability. This approach encourages minor, intentional adjustments in user behaviour to enrich the data available for system learning. This paper introduces epistemic interaction within the context of human-system communication, illustrating how deliberate interaction design can improve system understanding and adaptation. Through concrete examples, we demonstrate the potential of epistemic interaction to significantly advance human-computer interaction by leveraging intuitive human communication strategies to inform system design and functionality, offering a novel pathway for enriching user-system engagements.
LF Energy Webinar: Electrical Grid Modelling and Simulation Through PowSyBl -...DanBrown980551
Do you want to learn how to model and simulate an electrical network from scratch in under an hour?
Then welcome to this PowSyBl workshop, hosted by Rte, the French Transmission System Operator (TSO)!
During the webinar, you will discover the PowSyBl ecosystem as well as handle and study an electrical network through an interactive Python notebook.
PowSyBl is an open source project hosted by LF Energy, which offers a comprehensive set of features for electrical grid modelling and simulation. Among other advanced features, PowSyBl provides:
- A fully editable and extendable library for grid component modelling;
- Visualization tools to display your network;
- Grid simulation tools, such as power flows, security analyses (with or without remedial actions) and sensitivity analyses;
The framework is mostly written in Java, with a Python binding so that Python developers can access PowSyBl functionalities as well.
What you will learn during the webinar:
- For beginners: discover PowSyBl's functionalities through a quick general presentation and the notebook, without needing any expert coding skills;
- For advanced developers: master the skills to efficiently apply PowSyBl functionalities to your real-world scenarios.
JMeter webinar - integration with InfluxDB and GrafanaRTTS
Watch this recorded webinar about real-time monitoring of application performance. See how to integrate Apache JMeter, the open-source leader in performance testing, with InfluxDB, the open-source time-series database, and Grafana, the open-source analytics and visualization application.
In this webinar, we will review the benefits of leveraging InfluxDB and Grafana when executing load tests and demonstrate how these tools are used to visualize performance metrics.
Length: 30 minutes
Session Overview
-------------------------------------------
During this webinar, we will cover the following topics while demonstrating the integrations of JMeter, InfluxDB and Grafana:
- What out-of-the-box solutions are available for real-time monitoring JMeter tests?
- What are the benefits of integrating InfluxDB and Grafana into the load testing stack?
- Which features are provided by Grafana?
- Demonstration of InfluxDB and Grafana using a practice web application
To view the webinar recording, go to:
https://www.rttsweb.com/jmeter-integration-webinar
Slack (or Teams) Automation for Bonterra Impact Management (fka Social Soluti...Jeffrey Haguewood
Sidekick Solutions uses Bonterra Impact Management (fka Social Solutions Apricot) and automation solutions to integrate data for business workflows.
We believe integration and automation are essential to user experience and the promise of efficient work through technology. Automation is the critical ingredient to realizing that full vision. We develop integration products and services for Bonterra Case Management software to support the deployment of automations for a variety of use cases.
This video focuses on the notifications, alerts, and approval requests using Slack for Bonterra Impact Management. The solutions covered in this webinar can also be deployed for Microsoft Teams.
Interested in deploying notification automations for Bonterra Impact Management? Contact us at sales@sidekicksolutionsllc.com to discuss next steps.
Neuro-symbolic is not enough, we need neuro-*semantic*Frank van Harmelen
Neuro-symbolic (NeSy) AI is on the rise. However, simply machine learning on just any symbolic structure is not sufficient to really harvest the gains of NeSy. These will only be gained when the symbolic structures have an actual semantics. I give an operational definition of semantics as “predictable inference”.
All of this illustrated with link prediction over knowledge graphs, but the argument is general.
Dev Dives: Train smarter, not harder – active learning and UiPath LLMs for do...UiPathCommunity
💥 Speed, accuracy, and scaling – discover the superpowers of GenAI in action with UiPath Document Understanding and Communications Mining™:
See how to accelerate model training and optimize model performance with active learning
Learn about the latest enhancements to out-of-the-box document processing – with little to no training required
Get an exclusive demo of the new family of UiPath LLMs – GenAI models specialized for processing different types of documents and messages
This is a hands-on session specifically designed for automation developers and AI enthusiasts seeking to enhance their knowledge in leveraging the latest intelligent document processing capabilities offered by UiPath.
Speakers:
👨🏫 Andras Palfi, Senior Product Manager, UiPath
👩🏫 Lenka Dulovicova, Product Program Manager, UiPath
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...James Anderson
Effective Application Security in Software Delivery lifecycle using Deployment Firewall and DBOM
The modern software delivery process (or the CI/CD process) includes many tools, distributed teams, open-source code, and cloud platforms. Constant focus on speed to release software to market, along with the traditional slow and manual security checks has caused gaps in continuous security as an important piece in the software supply chain. Today organizations feel more susceptible to external and internal cyber threats due to the vast attack surface in their applications supply chain and the lack of end-to-end governance and risk management.
The software team must secure its software delivery process to avoid vulnerability and security breaches. This needs to be achieved with existing tool chains and without extensive rework of the delivery processes. This talk will present strategies and techniques for providing visibility into the true risk of the existing vulnerabilities, preventing the introduction of security issues in the software, resolving vulnerabilities in production environments quickly, and capturing the deployment bill of materials (DBOM).
Speakers:
Bob Boule
Robert Boule is a technology enthusiast with PASSION for technology and making things work along with a knack for helping others understand how things work. He comes with around 20 years of solution engineering experience in application security, software continuous delivery, and SaaS platforms. He is known for his dynamic presentations in CI/CD and application security integrated in software delivery lifecycle.
Gopinath Rebala
Gopinath Rebala is the CTO of OpsMx, where he has overall responsibility for the machine learning and data processing architectures for Secure Software Delivery. Gopi also has a strong connection with our customers, leading design and architecture for strategic implementations. Gopi is a frequent speaker and well-known leader in continuous delivery and integrating security into software delivery.
1. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
2.5G 1490nm 40km SFP Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20210616 1.0
Michael
Su
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 2.5G 1490nm 40km SFP Transceiver
Model SFP-2.5G-CWDM-1490-40-T02
File No. SFP-2.5G-CWDM-1490-40-T02#151081
Version 1.0
Issuing Date 2019-12-19
2. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
GLsun SFP-2.5G-CWDM-1490-40, SFP transceivers are high performance, cost effective
modules supporting data-rate of 2.5Gb/s and 40km transmission distance with SMF. The
transceiver consists of three sections: an uncooled CWDM DFB laser transmitter, a PIN
photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All
modules satisfy class I laser safety requirements. The transceivers are compatible with SFP
Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA.
Product Feature
Supports bit rates up to 2.5Gbps
Duplex LC connector
Hot pluggable SFP footprint
CWDM 1490nm laser transmitter and PIN photo-detector
Applicable for 40Km SMF connection
Low power consumption, < 0.8W
Digital Diagnostic Monitor Interface
Compliant with SFP MSA and SFF-8472
Very low EMI and excellent ESD protection
Operating case temperature:
Commercial: 0 to 70 °C
Industrial: -40 to 85 °C
Applications
SDH STM-16 and SONET OC-48 system
WDM systems
Switch to Switch interface
Switched backplane applications
Router/Server interface
Other optical transmission systems
General Specifications
Parameter Symbol Min. Typ Max. Unit Note
Data Rate DR 2.5 Gb/s
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc5 220 mA
Operating Case Temp.
Tc 0 70
°C
TI -40 85
3. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Functional Diagram
Absolute Maximum Ratings
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the
transceiver.
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Notes:
1. TD+/- are internally AC coupled with 100Ω differential termination inside the module.
2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ
resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at
the user SERDES.
Parameter Symbol Min. Max. Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature TS -40 85 °C
Relative Humidity RH 0 85 %
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data input swing VIN, PP 120 820 mVpp 1
Tx Disable Input-High VIH 2.0 Vcc+0.3 V
Tx Disable Input-Low VIL 0 0.8 V
Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2
Tx Fault Output-Low VOL 0 0.8 V 2
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 300 650 800 mVpp 3
Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2
Rx LOS Output-Low VROL 0 0.8 V 2
4. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Notes:
1. λ means 1270nm~1610nm, Total 18 wavelengths, 20nm spacing.
2. Measured at 2.5Gb/s with PRBS 2 223 – 1
NRZ test pattern.
3. Unfiltered, measured with a PRBS223 – 1
test pattern @2.5Gbps
4. Measured at 2.5Gb/s with PRBS 223 – 1
NRZ test pattern for BER < 1x10-12
Pin Descriptions
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ λ-7.5nm λ λ+7.5nm nm 1
Ave. output power (Enabled) PAVE -5 0 dBm 2
Extinction Ratio ER 9 dB 2
RMS spectral width Δλ 1 nm
Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 3
Dispersion penalty TDP 3.9 dB
Output Optical Eye ITU-T G.957 Compliant
Receiver
Operating Wavelength λ 1270 1610 nm
Receiver Sensitivity PSEN1 -18 dBm 4
Overload PAVE -3 dBm 4
LOS Assert Pa -35 dBm
LOS De-assert Pd -19 dBm
LOS Hysteresis Pd-Pa 0.5 dB
5. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Notes:
1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And
should be pulled up with a 4.7 – 10KΩ resistor on the host board.
2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within
the module with a 4.7 – 10KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined
High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled
3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K –
10KΩ resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V.
Mod-Def 0 has been grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4. When high, this output indicates loss of signal (LOS). Low indicates normal operation.
5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines
which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done
inside the module and is thus not required on the host board.
6. TD+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with
100Ω differential termination inside the module. The AC coupling is done inside the module and is
thus not required on the host board.
Pin Symbol Name/Description Notes
1 VeeT Tx ground
2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1
3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2
4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3
5 MOD-DEF1 2 wire serial interface clock input (SCL) 3
6 MOD-DEF0 Model present indication 3
7 Rate select No connection
8 LOS Rx loss of signal, Open Collector Output, active “H” 4
9 VeeR Rx ground
10 VeeR Rx ground
11 VeeR Rx ground
12 RD- Inverse received data out 5
13 RD+ Received data out 5
14 VeeR Rx ground
15 VccR Rx power supply
16 VccT Tx power supply
17 VeeT Tx ground
18 TD+ Transmit data in 6
19 TD- Inverse transmit data in 6
20 VeeT Tx ground
6. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
Digital Diagnostic Specifications
The SFP-2.5G-CWDM-1490-40-T02 transceivers can be used in host systems that require either
internally or externally calibrated digital diagnostics.
Notes:
1. When Operating temp.=0~70 ºC, the range will be min=-5, Max=+75
2. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
3. Internal / External Calibration compatible.
Typical Interface Circuit
Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 2 80 ±10% 2
Transmitter output power DTx-Power dBm -8 8 ±3dB
Receiver average input power DRx-Power dBm -21 0 ±3dB
7. SFP-2.5G-CWDM-1490-40-T02#151081
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
Package Dimensions
Ordering Information
Wavelength Latch Color
1490nm Violet
Part Number Description
SFP-2.5G-CWDM-1490-40-T02-C SFP, 2.5G, CWDM, 40Km, 0~70℃,
with Digital Diagnostic Monitor
SFP-2.5G-CWDM-1490-40-T02-I SFP, 2.5G, CWDM, 40Km, -40~85℃,
with Digital Diagnostic Monitor