SlideShare a Scribd company logo
1 of 7
Download to read offline
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
2.5G 1550nm 100km SFP Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20210616 1.0
Michael
Su
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 2.5G 1550nm 100km SFP Transceiver
Model SFP-2.5G-LH100-55-T02
File No. SFP-2.5G-LH100-55-T02#151063
Version 1.0
Issuing Date 2019-12-19
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
GLsun SFP-2.5G-LH100-55, SFP transceivers are high performance, cost effective modules
supporting dual data-rate of 2.5Gbps and 100km transmission distance with SMF. The transceiver
consists of three sections: a DFB laser transmitter, a APD photodiode integrated with a
trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety
requirements. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and
SFF-8472. For further information, please refer to SFP MSA.
Product Feature
Supports 2.5Gbps bit rates
Duplex LC connector
Hot pluggable SFP footprint
1550nm DFB laser transmitter and APD photo-detector
Applicable for 100Km SMF connection
Low power consumption, < 1.0W
Digital Diagnostic Monitor Interface
Compliant with SFP MSA and SFF-8472
Very low EMI and excellent ESD protection
Operating case temperature:
Commercial: 0 to 70 °C
Industrial: -40 to 85 °C
Applications
SDH STM-16 and SONET OC-48 system
2X Fiber Channel
Switch to Switch interface
Switched backplane applications
Router/Server interface
Other optical transmission systems
General Specifications
Parameter Symbol Min. Typ Max. Unit Note
Data Rate DR 1.2288 2.5 2.67 Gb/s
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc5 300 mA
Operating Case Temp.
Tc 0 70
°C
TI -40 85
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Functional Diagram
Absolute Maximum Ratings
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the
transceiver.
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Notes:
1. TD+/- are internally AC coupled with 100Ω differential termination inside the module.
2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ
resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at
the user SERDES.
Parameter Symbol Min. Max. Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature TS -40 85 °C
Relative Humidity RH 0 85 %
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data input swing VIN, PP 300 1800 mVpp 1
Tx Disable Input-High VIH 2.0 Vcc+0.3 V
Tx Disable Input-Low VIL 0 0.8 V
Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2
Tx Fault Output-Low VOL 0 0.8 V 2
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 400 1000 mVpp 3
Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2
Rx LOS Output-Low VROL 0 0.8 V 2
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Notes:
1. Measured at 2.5Gb/s with PRBS 2 223 – 1
NRZ test pattern.
2. Unfiltered, measured with a PRBS223 – 1
test pattern @2.5Gbps
3. Measured at 2.5Gb/s with PRBS 223 – 1
NRZ test pattern for BER < 1x10-12
Pin Descriptions
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ 1530 1550 1565 nm
Ave. output power (Enabled) PAVE 0 5 dBm 1
Extinction Ratio ER 9 dB 1
Side mode Suppression Ratio SMSR 30 dB
RMS spectral width Δλ 1 nm
Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 2
Dispersion penalty TDP 3.2 dB
Output Optical Eye ITU-T G.957 Compliant
Receiver
Operating Wavelength λ 1270 1610 nm
Receiver Sensitivity PSEN1 -28 dBm 3
Overload PAVE -7 dBm 3
LOS Assert Pa -40 dBm
LOS De-assert Pd -29 dBm
LOS Hysteresis Pd-Pa 0.5 dB
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Notes:
1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And
should be pulled up with a 4.7 – 10KΩ resistor on the host board.
2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within
the module with a 4.7 – 10KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined
High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled
3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K –
10KΩ resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V.
Mod-Def 0 has been grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4. When high, this output indicates loss of signal (LOS). Low indicates normal operation.
5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines
which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done
inside the module and is thus not required on the host board.
6. TD+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with
100Ω differential termination inside the module. The AC coupling is done inside the module and is
thus not required on the host board.
Pin Symbol Name/Description Notes
1 VeeT Tx ground
2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1
3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2
4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3
5 MOD-DEF1 2 wire serial interface clock input (SCL) 3
6 MOD-DEF0 Model present indication 3
7 Rate select No connection
8 LOS Rx loss of signal, Open Collector Output, active “H” 4
9 VeeR Rx ground
10 VeeR Rx ground
11 VeeR Rx ground
12 RD- Inverse received data out 5
13 RD+ Received data out 5
14 VeeR Rx ground
15 VccR Rx power supply
16 VccT Tx power supply
17 VeeT Tx ground
18 TD+ Transmit data in 6
19 TD- Inverse transmit data in 6
20 VeeT Tx ground
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
Digital Diagnostic Specifications
The SFP-2.5G-LH100-55-T02 transceivers can be used in host systems that require either internally or
externally calibrated digital diagnostics.
Notes:
1. When Operating temp.=0~70 ºC, the range will be min=-5, Max=+75
2. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
3. Internal / External Calibration compatible.
Typical Interface Circuit
Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 2 80 ±10% 2
Transmitter output power DTx-Power dBm -3 8 ±3dB
Receiver average input power DRx-Power dBm -31 0 ±3dB
SFP-2.5G-LH100-55-T02#151063
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
Package Dimensions
Ordering Information
Part Number Description
SFP-2.5G-LH100-55-T02-C SFP, 2.5G, 1550nm, 100Km, 0~70℃, with Digital Diagnostic Monitor
SFP-2.5G-LH100-55-T02-I SFP, 2.5G, 1550nm, 100Km, -40~85℃, with Digital Diagnostic Monitor

More Related Content

Similar to sfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdf

Similar to sfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdf (20)

sfp-2.5g-cwdm-1370nm-80km-fiber-optical-module-151093.pdf
sfp-2.5g-cwdm-1370nm-80km-fiber-optical-module-151093.pdfsfp-2.5g-cwdm-1370nm-80km-fiber-optical-module-151093.pdf
sfp-2.5g-cwdm-1370nm-80km-fiber-optical-module-151093.pdf
 
sfp-2.5g-cwdm-1390nm-80km-fiber-optical-module-151094.pdf
sfp-2.5g-cwdm-1390nm-80km-fiber-optical-module-151094.pdfsfp-2.5g-cwdm-1390nm-80km-fiber-optical-module-151094.pdf
sfp-2.5g-cwdm-1390nm-80km-fiber-optical-module-151094.pdf
 
sfp-2.5g-cwdm-1530nm-80kmfiber-optical-module-151101.pdf
sfp-2.5g-cwdm-1530nm-80kmfiber-optical-module-151101.pdfsfp-2.5g-cwdm-1530nm-80kmfiber-optical-module-151101.pdf
sfp-2.5g-cwdm-1530nm-80kmfiber-optical-module-151101.pdf
 
sfp-2.5g-cwdm-1330nm-40km-fiber-optical-module-151073.pdf
sfp-2.5g-cwdm-1330nm-40km-fiber-optical-module-151073.pdfsfp-2.5g-cwdm-1330nm-40km-fiber-optical-module-151073.pdf
sfp-2.5g-cwdm-1330nm-40km-fiber-optical-module-151073.pdf
 
sfp-2.5g-cwdm-1570nm-80km-fiber-optical-module-151103.pdf
sfp-2.5g-cwdm-1570nm-80km-fiber-optical-module-151103.pdfsfp-2.5g-cwdm-1570nm-80km-fiber-optical-module-151103.pdf
sfp-2.5g-cwdm-1570nm-80km-fiber-optical-module-151103.pdf
 
sfp-2.5g-cwdm-1530nm-40km-fiber-optical-module-151083.pdf
sfp-2.5g-cwdm-1530nm-40km-fiber-optical-module-151083.pdfsfp-2.5g-cwdm-1530nm-40km-fiber-optical-module-151083.pdf
sfp-2.5g-cwdm-1530nm-40km-fiber-optical-module-151083.pdf
 
sfp-2.5g-cwdm-1570nm-40km-fiber-optical-module-151085.pdf
sfp-2.5g-cwdm-1570nm-40km-fiber-optical-module-151085.pdfsfp-2.5g-cwdm-1570nm-40km-fiber-optical-module-151085.pdf
sfp-2.5g-cwdm-1570nm-40km-fiber-optical-module-151085.pdf
 
sfp-2.5g-cwdm-1610nm-80km-fiber-optical-module-151105.pdf
sfp-2.5g-cwdm-1610nm-80km-fiber-optical-module-151105.pdfsfp-2.5g-cwdm-1610nm-80km-fiber-optical-module-151105.pdf
sfp-2.5g-cwdm-1610nm-80km-fiber-optical-module-151105.pdf
 
sfp-2.5g-cwdm-1590nm-80km-fiber-optical-module-151104.pdf
sfp-2.5g-cwdm-1590nm-80km-fiber-optical-module-151104.pdfsfp-2.5g-cwdm-1590nm-80km-fiber-optical-module-151104.pdf
sfp-2.5g-cwdm-1590nm-80km-fiber-optical-module-151104.pdf
 
sfp-2.5g-sx-1310nm-2km-fiber-optical-module-t02-151059.pdf
sfp-2.5g-sx-1310nm-2km-fiber-optical-module-t02-151059.pdfsfp-2.5g-sx-1310nm-2km-fiber-optical-module-t02-151059.pdf
sfp-2.5g-sx-1310nm-2km-fiber-optical-module-t02-151059.pdf
 
sfp-2.5g-cwdm-1370nm-40km-optical-module-151075.pdf
sfp-2.5g-cwdm-1370nm-40km-optical-module-151075.pdfsfp-2.5g-cwdm-1370nm-40km-optical-module-151075.pdf
sfp-2.5g-cwdm-1370nm-40km-optical-module-151075.pdf
 
sfp-2.5g-cwdm-1510nm-80km-fiber-optical-module-151000.pdf
sfp-2.5g-cwdm-1510nm-80km-fiber-optical-module-151000.pdfsfp-2.5g-cwdm-1510nm-80km-fiber-optical-module-151000.pdf
sfp-2.5g-cwdm-1510nm-80km-fiber-optical-module-151000.pdf
 
sfp-2.5g-cwdm-1410nm-80km-fiber-optical-module-151095.pdf
sfp-2.5g-cwdm-1410nm-80km-fiber-optical-module-151095.pdfsfp-2.5g-cwdm-1410nm-80km-fiber-optical-module-151095.pdf
sfp-2.5g-cwdm-1410nm-80km-fiber-optical-module-151095.pdf
 
sfp-2.5g-cwdm-1310nm-40km-fiber-optical-module-151072.pdf
sfp-2.5g-cwdm-1310nm-40km-fiber-optical-module-151072.pdfsfp-2.5g-cwdm-1310nm-40km-fiber-optical-module-151072.pdf
sfp-2.5g-cwdm-1310nm-40km-fiber-optical-module-151072.pdf
 
sfp-2.5g-cwdm-1450nm-80km-fiber-optical-module-151097.pdf
sfp-2.5g-cwdm-1450nm-80km-fiber-optical-module-151097.pdfsfp-2.5g-cwdm-1450nm-80km-fiber-optical-module-151097.pdf
sfp-2.5g-cwdm-1450nm-80km-fiber-optical-module-151097.pdf
 
sfp-2.5g-cwdm-1610nm-40km-transceiver-module-151087.pdf
sfp-2.5g-cwdm-1610nm-40km-transceiver-module-151087.pdfsfp-2.5g-cwdm-1610nm-40km-transceiver-module-151087.pdf
sfp-2.5g-cwdm-1610nm-40km-transceiver-module-151087.pdf
 
sfp-2.5g-cwdm-1350nm-40km-fiber-optical-module-151074.pdf
sfp-2.5g-cwdm-1350nm-40km-fiber-optical-module-151074.pdfsfp-2.5g-cwdm-1350nm-40km-fiber-optical-module-151074.pdf
sfp-2.5g-cwdm-1350nm-40km-fiber-optical-module-151074.pdf
 
sfp-2.5g-cwdm-1470nm-80km-fiber-optical-module-151098.pdf
sfp-2.5g-cwdm-1470nm-80km-fiber-optical-module-151098.pdfsfp-2.5g-cwdm-1470nm-80km-fiber-optical-module-151098.pdf
sfp-2.5g-cwdm-1470nm-80km-fiber-optical-module-151098.pdf
 
sfp-2.5g-cwdm-1390nm-40km-fiber-transceiver-151076.pdf
sfp-2.5g-cwdm-1390nm-40km-fiber-transceiver-151076.pdfsfp-2.5g-cwdm-1390nm-40km-fiber-transceiver-151076.pdf
sfp-2.5g-cwdm-1390nm-40km-fiber-transceiver-151076.pdf
 
sfp-2.5g-cwdm-1430nm-40km-fiber-optical-module-151078.pdf
sfp-2.5g-cwdm-1430nm-40km-fiber-optical-module-151078.pdfsfp-2.5g-cwdm-1430nm-40km-fiber-optical-module-151078.pdf
sfp-2.5g-cwdm-1430nm-40km-fiber-optical-module-151078.pdf
 

More from GLsun Mall

osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
GLsun Mall
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
GLsun Mall
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
GLsun Mall
 

More from GLsun Mall (20)

to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfto56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
 
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfto56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
 
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfto56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
 
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfosw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
 
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfosw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
 
fsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docfsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.doc
 
fsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docfsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.doc
 
fsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docfsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.doc
 
fsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docfsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.doc
 
fsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docfsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.doc
 
multi-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfmulti-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdf
 
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
 
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
 
1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf
 
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
 
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
 
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
 

Recently uploaded

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
WSO2
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
panagenda
 

Recently uploaded (20)

TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Architecting Cloud Native Applications
Architecting Cloud Native ApplicationsArchitecting Cloud Native Applications
Architecting Cloud Native Applications
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
GenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdfGenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdf
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Navi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Navi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot ModelNavi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Navi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot Model
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 

sfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdf

  • 1. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 1 - 2.5G 1550nm 100km SFP Transceiver Specification Revision Record Date Version Page Revision Description Prepare Approve 20210616 1.0 Michael Su All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission, any unit or individual can’t reproduce, copy or use it for any commercial purpose. Product 2.5G 1550nm 100km SFP Transceiver Model SFP-2.5G-LH100-55-T02 File No. SFP-2.5G-LH100-55-T02#151063 Version 1.0 Issuing Date 2019-12-19
  • 2. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 2 - Product Description GLsun SFP-2.5G-LH100-55, SFP transceivers are high performance, cost effective modules supporting dual data-rate of 2.5Gbps and 100km transmission distance with SMF. The transceiver consists of three sections: a DFB laser transmitter, a APD photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA. Product Feature Supports 2.5Gbps bit rates Duplex LC connector Hot pluggable SFP footprint 1550nm DFB laser transmitter and APD photo-detector Applicable for 100Km SMF connection Low power consumption, < 1.0W Digital Diagnostic Monitor Interface Compliant with SFP MSA and SFF-8472 Very low EMI and excellent ESD protection Operating case temperature: Commercial: 0 to 70 °C Industrial: -40 to 85 °C Applications SDH STM-16 and SONET OC-48 system 2X Fiber Channel Switch to Switch interface Switched backplane applications Router/Server interface Other optical transmission systems General Specifications Parameter Symbol Min. Typ Max. Unit Note Data Rate DR 1.2288 2.5 2.67 Gb/s Supply Voltage Vcc 3.13 3.3 3.47 V Supply Current Icc5 300 mA Operating Case Temp. Tc 0 70 °C TI -40 85
  • 3. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 3 - Functional Diagram Absolute Maximum Ratings Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver. Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V) Notes: 1. TD+/- are internally AC coupled with 100Ω differential termination inside the module. 2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V. 3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user SERDES. Parameter Symbol Min. Max. Unit Note Supply Voltage Vcc -0.5 4.0 V Storage Temperature TS -40 85 °C Relative Humidity RH 0 85 % Parameter Symbol Min. Typ Max. Unit Note Transmitter Differential data input swing VIN, PP 300 1800 mVpp 1 Tx Disable Input-High VIH 2.0 Vcc+0.3 V Tx Disable Input-Low VIL 0 0.8 V Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2 Tx Fault Output-Low VOL 0 0.8 V 2 Input differential impedance Rin 100 Ω Receiver Differential data output swing Vout,pp 400 1000 mVpp 3 Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2 Rx LOS Output-Low VROL 0 0.8 V 2
  • 4. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 4 - Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V) Notes: 1. Measured at 2.5Gb/s with PRBS 2 223 – 1 NRZ test pattern. 2. Unfiltered, measured with a PRBS223 – 1 test pattern @2.5Gbps 3. Measured at 2.5Gb/s with PRBS 223 – 1 NRZ test pattern for BER < 1x10-12 Pin Descriptions Parameter Symbol Min. Typ Max. Unit Note Transmitter Operating Wavelength λ 1530 1550 1565 nm Ave. output power (Enabled) PAVE 0 5 dBm 1 Extinction Ratio ER 9 dB 1 Side mode Suppression Ratio SMSR 30 dB RMS spectral width Δλ 1 nm Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 2 Dispersion penalty TDP 3.2 dB Output Optical Eye ITU-T G.957 Compliant Receiver Operating Wavelength λ 1270 1610 nm Receiver Sensitivity PSEN1 -28 dBm 3 Overload PAVE -7 dBm 3 LOS Assert Pa -40 dBm LOS De-assert Pd -29 dBm LOS Hysteresis Pd-Pa 0.5 dB
  • 5. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 5 - Notes: 1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And should be pulled up with a 4.7 – 10KΩ resistor on the host board. 2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10KΩ resistor. Its states are: Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled 3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩ resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V. Mod-Def 0 has been grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4. When high, this output indicates loss of signal (LOS). Low indicates normal operation. 5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. 6. TD+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. Pin Symbol Name/Description Notes 1 VeeT Tx ground 2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1 3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2 4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3 5 MOD-DEF1 2 wire serial interface clock input (SCL) 3 6 MOD-DEF0 Model present indication 3 7 Rate select No connection 8 LOS Rx loss of signal, Open Collector Output, active “H” 4 9 VeeR Rx ground 10 VeeR Rx ground 11 VeeR Rx ground 12 RD- Inverse received data out 5 13 RD+ Received data out 5 14 VeeR Rx ground 15 VccR Rx power supply 16 VccT Tx power supply 17 VeeT Tx ground 18 TD+ Transmit data in 6 19 TD- Inverse transmit data in 6 20 VeeT Tx ground
  • 6. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 6 - Digital Diagnostic Specifications The SFP-2.5G-LH100-55-T02 transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics. Notes: 1. When Operating temp.=0~70 ºC, the range will be min=-5, Max=+75 2. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser 3. Internal / External Calibration compatible. Typical Interface Circuit Parameter Symbol Units Min. Max. Accuracy Note Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1 Transceiver supply voltage DVoltage V 2.8 4.0 ±3% Transmitter bias current DBias mA 2 80 ±10% 2 Transmitter output power DTx-Power dBm -3 8 ±3dB Receiver average input power DRx-Power dBm -31 0 ±3dB
  • 7. SFP-2.5G-LH100-55-T02#151063 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 7 - Package Dimensions Ordering Information Part Number Description SFP-2.5G-LH100-55-T02-C SFP, 2.5G, 1550nm, 100Km, 0~70℃, with Digital Diagnostic Monitor SFP-2.5G-LH100-55-T02-I SFP, 2.5G, 1550nm, 100Km, -40~85℃, with Digital Diagnostic Monitor