ELVIS
Relay Management
Tuomas Vanninen
SAP Work Manager
Mobile
Oracle Primavera
Project Portfolio &
Management
Primavera adapter
Maximo Spatial
IBM Maximo Asset
Management
ESRI ArcGIS
GIS
Electron CAPE
Relay simulation
IPS Relex
Relay Management
Siemens PSS®ODMS
Grid modeling
Siemens PSS®E
Grid calculation
OSIsoft PI
AF & ProcessBook
Asset health
OSIsoft PI
Real-time &
data storage
other integrations to Accounting, Metering,
Document Management, Business Intelligens,
Invoicing, among others
SCADA
ELVIS
– THE NEW PLATFORM
FOR ASSET AND OPERATION
MANAGEMENT
Integrated best-of-breed standard
software products
Process
Two main processes
1. Asset management
• preventive maintenance
• corrective maintenance
• substation inspection
• protection data from greenfield project
2. Relay setting handling
• settings change
• relay setting calculation and simulation
IPS
• relay setting management
• setting file import/export between
manufacturer tool and IPS
• preventive maintenance task list
• testing – omicron file export (.xrio)
• warehouse functionality
Maximo
• workorders and planning/scheduling
• fault reporting
• actuals
• automatic billing
• warehouse functionality
Tasks in different applications
Protection maintenance and setting
management - IPS
• Relays as assets
• Same setting data in IPS
and in relay
• Knowledge about relay
functions
• Preventing human errors
import/export capabilities
• No separate excel files
Relay setting management – setter view
• Manufacturer independent
view to main settings!
• Use of Parameter sets and
programs
• Setting tips for each
parameter
• Setting states which setter
can lock
• Effective comparison e.g.
"issued" vs. "in relay"
Workflow
• Configurable by
maintenance planner
• Who did what and when?
• Tracking of unfinished jobs
• Payment process starts
after completed jobs
• GSR > RSR
Setting calculation and Simulation - CAPE
• Combines ALL ELVIS information
• To visualize settings
• To analyze co-operation of the relays
in different scenarios
• To find root causes for the faults
occurred in the network
• To make setting calculation (more)
"automatic"
• Also used in the hazardous voltage
process
Reporting
• Fault statistics e.g. failure rate of a
certain relay type is accelerating
• Repair time tracking from fault to
commissioning
• Info for setters about changes in CT or
VT ratios and power line data
• Light reports by using effective filtering
inside IPS
Fingrid Oyj
Läkkisepäntie 21
FI-00620 Helsinki
P.O.Box 530
FI-00101 Helsinki, Finland
Tel. +358 30 395 5000
Fax. +358 30 395 5196
Relay..Set..Go!

Relay management ELVIS event Tuomas Vanninen

  • 1.
  • 2.
    SAP Work Manager Mobile OraclePrimavera Project Portfolio & Management Primavera adapter Maximo Spatial IBM Maximo Asset Management ESRI ArcGIS GIS Electron CAPE Relay simulation IPS Relex Relay Management Siemens PSS®ODMS Grid modeling Siemens PSS®E Grid calculation OSIsoft PI AF & ProcessBook Asset health OSIsoft PI Real-time & data storage other integrations to Accounting, Metering, Document Management, Business Intelligens, Invoicing, among others SCADA ELVIS – THE NEW PLATFORM FOR ASSET AND OPERATION MANAGEMENT Integrated best-of-breed standard software products
  • 3.
    Process Two main processes 1.Asset management • preventive maintenance • corrective maintenance • substation inspection • protection data from greenfield project 2. Relay setting handling • settings change • relay setting calculation and simulation
  • 4.
    IPS • relay settingmanagement • setting file import/export between manufacturer tool and IPS • preventive maintenance task list • testing – omicron file export (.xrio) • warehouse functionality Maximo • workorders and planning/scheduling • fault reporting • actuals • automatic billing • warehouse functionality Tasks in different applications
  • 5.
    Protection maintenance andsetting management - IPS • Relays as assets • Same setting data in IPS and in relay • Knowledge about relay functions • Preventing human errors import/export capabilities • No separate excel files
  • 6.
    Relay setting management– setter view • Manufacturer independent view to main settings! • Use of Parameter sets and programs • Setting tips for each parameter • Setting states which setter can lock • Effective comparison e.g. "issued" vs. "in relay"
  • 7.
    Workflow • Configurable by maintenanceplanner • Who did what and when? • Tracking of unfinished jobs • Payment process starts after completed jobs • GSR > RSR
  • 8.
    Setting calculation andSimulation - CAPE • Combines ALL ELVIS information • To visualize settings • To analyze co-operation of the relays in different scenarios • To find root causes for the faults occurred in the network • To make setting calculation (more) "automatic" • Also used in the hazardous voltage process
  • 9.
    Reporting • Fault statisticse.g. failure rate of a certain relay type is accelerating • Repair time tracking from fault to commissioning • Info for setters about changes in CT or VT ratios and power line data • Light reports by using effective filtering inside IPS
  • 10.
    Fingrid Oyj Läkkisepäntie 21 FI-00620Helsinki P.O.Box 530 FI-00101 Helsinki, Finland Tel. +358 30 395 5000 Fax. +358 30 395 5196 Relay..Set..Go!