SlideShare a Scribd company logo
PROPOSAL DEPLOY SAN at VINADATA
                                              STEP by STEP




File Name   : Proposal SAN STEP by STEP.doc                  Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                              Page 1 of 16
Contents
1.     PHASE 1: Kích hoạt hệ thống SAN tại Cộng Hòa ............................................................... 3

     1.1     Thiết bị hiện tại ............................................................................................................ 3

     1.2     Mục tiêu ....................................................................................................................... 3

     1.3     Danh mục cần đầu tư: .................................................................................................. 3

     1.4     Mô hình đấu nối: .......................................................................................................... 4

2.     PHASE 2: Disaster Recovery Site ....................................................................................... 5

     2.1     Mục tiêu: ...................................................................................................................... 5

     2.2     Mô hình kết nối ............................................................................................................ 5

       2.2.1       Cơ chế hoạt động ................................................................................................. 6

       2.2.2       Diễn giải kết nối .................................................................................................... 6

       2.2.3       Chức năng MirrorView .......................................................................................... 7

       Một số tình huống phục hồi ................................................................................................. 8

     2.3     Lợi ích của giải pháp...................................................................................................11

     2.4     Danh mục cần đầu tư .................................................................................................11

3.     PHASE 3: NÂNG CẤP HỆ THỐNG BACKUP ....................................................................12

     3.1     Mô hình Serverless Backup ........................................................................................12

     3.2     Danh mục cần đầu tư .................................................................................................13

4.     PHASE 4: Tăng cường Security – Monitor – Multi Connecting...........................................13

     4.1     Security.......................................................................................................................13

     4.2     Monitoring ...................................................................................................................14

     4.3     Multi VSAN – IVR........................................................................................................15

     4.4     Danh mục cần đầu tư ..................................................................................................15

File Name    : Proposal SAN STEP by STEP.doc                                                                  Author : Phạm Hồng Phước
Date         : 21-Oct-2008                                                                                              Page 2 of 16
1. PHASE 1: Kích hoạt hệ thống SAN tại Cộng Hòa

        1.1 Thiết bị hiện tại

01 Storage EMC CX3-40c:
     Dung lượng: FC HDD: 15 x 146Gb (10K rpm)
                 FC HDD: 15 x 146Gb (15K rpm)
                 SATAII HDD: 3 x 15 x 500Gb
02 Cisco MDS 9509
02 SAN Switch McDATA DS4700
01 Tape Library Quantum PX502 38 slot + 10 Tape LTO-3 (400Gb)
01 Software EMC Networker + license cho Autochanger Module, license cho 15 connection,
license cho OS Linux

        1.2 Mục tiêu

_ Đưa hệ thống SAN vào hoạt động, có thể đáp ứng các nhu cầu SAN tại Site Cộng Hòa.
_ Đưa hệ thống backup tape library vào họat động, trước mắt đáp ứng nhu cầu backup data
cho VINADATA ‘s Office

        1.3 Danh mục cần đầu tư:
                                                                                      Gía
STT         Loại tài sản                                                 Số lượng              Thành tiền
                                     Description                                      (Price
 (No)       (Sort of facilities)                                         (Quantity)            (Total USD)
                                                                                      USD)
                                     Kết nối các port Management hệ
                                     thống SAN, Tape Library, MDS
                                     9509, Networker Server
   1        Switch Cisco 24 port     http://www.overstock.com/Electro    01           ~ 4000
                                     nics/Cisco-Catalyst-3560-Gigabit-
                                     Ethernet-
                                     Switch/2628347/product.html
                                     3 HDD; Support PCI-E  Dùng làm
   2        Server                   Server Backup (Control Tape         01           ~ 3000
                                     Library) và SAN Management.
                                     http://www.shopping.com/xPP-
   3        FC HBA LPe1150           network_adapters--                  01           ~ 800
                                     ietf_ip_over_fc




File Name   : Proposal SAN STEP by STEP.doc                                     Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                                 Page 3 of 16
1.4 Mô hình đấu nối:


                                                             Tape Library
                                                                PX502




                              HP Chassis Blade
                                   Server




                                  VSAN 1


                                  ISL between
                                    02 MDS




                                                  MDS 9509



                                                                        Networker Server
                                                                      (Control Tape Library)




                                   EMC CLARiiON
                                     CX3-40c



_ Dùng 02 MDS 9509 để làm core của mạng SAN  tận dụng được các function và
performance của MDS 9509.

_ Reserved 02 SAN Switch DS4700 cho các nhu cầu kết nối Site to Site với các khách hàng
khác.




File Name   : Proposal SAN STEP by STEP.doc                             Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                         Page 4 of 16
2. PHASE 2: Disaster Recovery Site

       2.1 Mục tiêu:
_ Tăng cường tính an toàn về mặt data và Service

_ Thêm 1 offer Disaster Recovery Site + Backup cho khách hàng

_ Data của Khách hàng có thể đặt server tại Công Hòa, backup ra Tape, Replicate data trên
SAN tại site Điện Biên Phủ. Và ngược lại

_ Ngoài việc offer cho khách hàng dịch vụ redundancy về Data, ta có thể offer thêm redundancy
service (2 hệ thống Mail Server đặt tại 02 site, 1 Active 1 Stanby với 02 hệ thống Database
được replicate giữa 02 site).

        2.2 Mô hình kết nối




File Name   : Proposal SAN STEP by STEP.doc                            Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                        Page 5 of 16
2.2.1 Cơ chế hoạt động
       Giải pháp kết nối và DR được xây dựng dựa trên việc kéo dài mạng SAN thông qua
    Black Fiber (FC Single Mode) - với 02 SAN Switch DS-4700 tại mỗi site làm core – từ
    Production Site (20bis Cộng Hòa) và Disaster Recovery Site (381 Điện Biên Phủ) kết
    hợp với giải pháp nhân bản dữ liệu đối xứng sử dụng phần mềm MirroView/S chạy trên hệ
    thống CLARiiON CX3 của EMC. Đường cáp quang sử dụng là 02 đường Dark Fibre với tốc
    độ 2Gb/s.

    Hai cổng trên hai thiết bị lưu trữ CX3-40c và CX3-40 trên hai SP (Storage Processor) sẽ
    được zoning trong cùng một zone, hai thiết bị lưu trữ sẽ cùng trên một domain.

    Kết nối từ lưu trữ đến patch panel sẽ sử dụng cáp multi mode chuẩn LC-LC.

    Phần mềm nhân bản đồng bộ MirrorView/S sẽ được cài đặt trên cả 2 site đảm bảo đồng bộ
    dữ liệu giữa hai trung tâm cũng như phục vụ cho giải pháp phục hồi thảm họa (Disarter
    Recovery).

    Bên cạnh đó, với mô hình được thiết kế ở trên, trung tâm dữ liệu chính của VINADATA tại
    đường Cộng Hòa sẽ sử dụng 02 Director MDS 9509 của Cisco để phân chia mạng SAN
    kết nối của các server (thuộc các project khác nhau) tại Production Site thành các VSAN,
    các MDS như đã biết sẽ đóng vai trò là các Core Switch. Giữa các Switch sẽ sử dụng kết
    nối ISL (Inter Switch Links).Trong tương lai, trung tâm dữ liệu chính tại đường Cộng Hòa
    của VINADATA sẽ có thêm rất nhiều SAN Switch với rất nhiều cổng kêt nối, việc sử dụng
    VSAN sẽ làm cho mô hình quản trị rõ ràng tách bạch, giúp cho việc quản lý trở nên dễ dàng
    hơn, bảo mật hơn

              2.2.2 Diễn giải kết nối
       Kết nối 02 hệ thống CX3 thông qua 02 đường Dark Fiber sẽ được join vào cùng 1
    domain, Mirror View Zone làm nhiệm vụ đường replicate/mirror data giữa 02 site.

    Tại DR Site các server sẽ được configure Zoning với các LUN trên CX3-40 thông qua SAN
    switch DS-4700 hoặc iSCSI Router (iSCSI SAN). Đảm bảo mỗi server connect đến CX3-40
    với 04 path

    Tại Production Site các server kết nối đến CX3-40c thông qua MDS 9509 phân ra thành
    nhiều VSAN khác nhau để quản trị rõ ràng cũng như thêm phần bảo mật.




File Name   : Proposal SAN STEP by STEP.doc                            Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                        Page 6 of 16
2.2.3 Chức năng MirrorView
        Sau khi thiết lập mối quan hệ nhân bản dữ liệu giữa hai hệ thống CLARiiON,
    MirrorView/S sẽ đảm bảo bảo vệ toàn bộ dữ liệu của hệ thống thứ nhất.

    Sau lần synchronize đầu tiên, toàn bộ dữ liệu trên hệ thống CX3-40C tại trung tâm chính
    cần được bảo vệ sẽ được MirrorView nhân bản sang hệ thống CX3-40C dự phòng.

                                              Source                      Target


                                    1                         2
                                                       Limited distance

                                    4                         3

               Lệnh ghi được ghi vào cache của CLARiiON tại trung tâm chính
               Lệnh ghi được chuyển qua đường kết nối FC và ghi vào cache của hệ
                  thống CLARiiON tại trung tâm dự phòng
               CLARiiON dự phòng ghi nhận là đã ghi xong dữ liệu
               CLARiiON chính ghi nhận với ứng dụng là đã ghi xong dữ liệu

Như vậy, trong trường hợp bình thường, toàn bộ dữ liệu cần bảo vệ ở trung tâm chính sẽ được
nhân bản sang trung tâm dự phòng

Trong trường hợp đường kết nối bị đứt, CLARiiON sẽ lưu trữ một bảng chứa các block đã bị
thay đổi kể từ khi đường kết nối bị đứt. Khi đường kết nối hoạt động trở lại, các block bị thay
đổi sẽ được copy sang hệ thống dự phòng.

Hệ thống hoạt động hoàn toàn ở mức thiết bị lưu trữ và không phụ thuộc vào máy chủ, hệ
điều hành và ứng dụng và cũng không đòi hỏi sự sẵn có của các hệ thống này vẫn bảo vệ
được dữ liệu.

CLARiiON là sản phẩm duy nhất của dòng tầm trung cho đồng bộ dữ liệu từ trung tâm dự
phòng về trung tâm chính theo cơ chế incremental, rút ngắn quá trình đồng bộ dữ liệu (xuống
còn khoảng vài chục phút tới vài giờ thay vì hàng ngày nếu phải đồng bộ 100% dữ liệu)

File Name   : Proposal SAN STEP by STEP.doc                               Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                           Page 7 of 16
Một số tình huống phục hồi
    Ổ đĩa tại trung tâm dữ liệu chính lỗi

Nếu ổ đĩa chứa dữ liệu tại trung tâm dữ liệu chính bị lỗi, các lệnh I/O sẽ bị từ chối cho đến khi ổ
đĩa đó được phục hồi lại. Trong quá trình này, người dùng có thể nâng cấp ổ đĩa tại trung tâm
dự phòng thành ổ đĩa chính và chuyển các lệnh I/O đến ổ đĩa này. Các truy xuất vẫn được thực
hiện bằng máy chủ ở trung tâm chính thông qua đường cáp quang tới ổ đĩa ở trung tâm dự
phòng. Điều này giúp biến bản sao ở trung tâm dự phòng thành một bản sao ánh xạ (mirror)
thực sự.

    Bộ xử lý lưu trữ (SP) điều khiển các ổ đĩa chính lỗi

Nếu bộ xử lý lưu trữ quản lý một ổ đĩa bị lỗi, thì MirrorView sẽ chuyển quyền quản lý sang bộ
xử lý lưu trữ khác cùng trên một dãy đĩa. Khi lỗi này xảy ra trên hệ thống lưu trữ chính, một
message được gửi đến hệ thống lưu trữ dự phòng để hệ thống lưu trữ dự phòng cũng sẽ
chuyển quyền quản lý ổ đĩa nhân bản sang bộ xử lý lưu trữ tương ứng. Nếu dữ liệu tại trung
tâm dự phòng bị gián đoạn, dữ liệu từ Write Intent Log được dùng để đồng bộ lại khi hệ thống
làm việc bình thường.




Trước khi bộ xử lý lưu trữ gặp lỗi: Cả hai ổ cứng logic (LUN) trên hai dãy đĩa đều được điều
khiển bởi Bộ xử lý lưu trữ A (SP A)




File Name   : Proposal SAN STEP by STEP.doc                                 Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                             Page 8 of 16
Khi xảy ra lỗi với bộ xử lý lưu trữ A: Các ổ đĩa được chuyển sang quản lý bởi bộ xử lý lưu trữ B
(SP B)

        Hệ thống lưu trữ chính bị lỗi

Nếu hệ thống lưu trữ chính chứa ổ đĩa chính bị lỗi, các lệnh đọc ghi của máy chủ (I/O) được
ngừng lại cho đến khi hệ thống lưu trữ được phục hồi. Cũng giống như ổ đĩa logic (LUN) chính
bị lỗi, người sử dụng có thể chọn cách nâng cấp hệ thống lưu trữ dự phòng lên thành hệ thống
chính và chuyển các lệnh đọc ghi của máy chủ sang hệ thống này.




File Name   : Proposal SAN STEP by STEP.doc                               Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                           Page 9 of 16
Trước khi hệ thống lưu trữ chính gặp lỗi: Ổ đĩa chính (trên dãy đĩa CLARiiON chính) có Mirror
ID là X




Sau khi có lỗi đối với hệ thống lưu trữ chính: Ổ đĩa chính vừa được nâng quyền (trên dãy đĩa
dự phòng CLARiiON ) có Mirror ID là Y

        Trung tâm dự phòng có lỗi và cách phục hồi

Khi trung tâm dự phòng gặp lỗi đương nhiên sẽ giảm khả năng dư thừa dự phòng hoặc không
thể truy cập dữ liệu từ trung tâm chính đến trung tâm dự phòng.

        Ổ đĩa dự phòng (LUN) lỗi

Nếu ổ đĩa vật lý dự phòng tại trung tâm dự phòng bị lỗi, người quản trị có thể chọn hoặc sửa ổ
đĩa đó hoặc gỡ bỏ ra khỏi mỗi quan hệ với các ổ đĩa Mirror khác. Nếu ổ đĩa được phục hồi, nó
phải được đồng bộ lại. Nếu ổ đĩa khác được chọn làm ổ đĩa dự phòng, ổ đĩa đó phải được
đồng bộ hoàn toàn.

        Bộ xử lý lưu trữ (SP) điều khiển các ổ đĩa dự phòng lỗi

Nếu bộ xử lý điều khiển một ổ đĩa tại trung tâm dự phòng gặp lỗi, hệ thống sẽ dừng lại cho đến
khi bộ xử lý đó được phục hồi. Khi bộ xử lý được phục hồi, dữ liệu nhân bản sẽ tự động đồng
bộ.




File Name   : Proposal SAN STEP by STEP.doc                              Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                          Page 10 of 16
2.3 Lợi ích của giải pháp
    Ngoài những lợi ích đã trình bày ở trên, thì còn có lợi ích về mặt đầu tư thiết bị. Nếu như
chúng ta muốn sử dụng MDS 9509 dùng làm core kết nối site to site, chúng ta cần đầu tư thêm
software va hardware cho MDS:

                  _ License Extension SAN: Price: $10.000 x 2.

    http://www.pcconnection.com/IPA/Shop/Product/Detail.htm?sku=8078486

                  _ Module support transceiver Longwave 10km (DS-X9124): Price: €14,429 x 2

    http://www.pcwb.ie/catalogue/item/CISMDS06

        2.4 Danh mục cần đầu tư
                                                                        Số lượng      Gía
STT         Loại tài sản                                                                           Thành tiền
                                       Description                      (Quantity     (Price
 (No)       (Sort of facilities)                                                                   (Total USD)
                                                                        USD)          USD)
            Cable single mode
   1                                   FC Cable                         06            65           390
            LC-LC duplex 30m
            Cable single mode
   2                                   FC Cable                         04            40           160
            LC-LC duplex 8m
            Cable Multi mode
   3        50/125 SC-LC duplex        FC Cable                         15            40           600
            8m
            Cable Multi mode
   4        50/125 SC-LC duplex        FC Cable                         4             50           200
            16m
            Cable Multi mode
   6        50/125 SC-SC duplex        FC Cable                         12            40           480
            8m
            Module Long Wave           Long Wave Optic KIT-10Km
   7        (DSED-LWKT10)              www.peppm.org/Products/emc       04            240          960
                                       hardware/price.pdf
                                       MIRRORVIEW SYNC CX3-40
            License Mirror View/S      http://computer.pwgsc.gc.ca/ht
   8                                                                    02            15000        30000
            (MVS34)                    docs/storage/sannas/vendors/
                                       emc/san1b.pdf
                                       _ Tư vấn thiết kế DR
                                       _ Cài đặt Mirror View tại 02
                                       site
                                       _ Cấu hình đồng bộ dữ liệu
   9        Service                                                                                10000
                                       _ Training 02 ngày
                                       _ Maintenance System 02
                                       tháng


File Name   : Proposal SAN STEP by STEP.doc                                         Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                                     Page 11 of 16
3. PHASE 3: NÂNG CẤP HỆ THỐNG BACKUP
Hiện tại chúng ta có:
        _Tape Library PX502 (1 Drive – 36 slot – 10 tape)
        _ EMC Networker (phần mềm Backup) + License cho PX502 + License cho việc backup
từ môi trường Linux + License cho 15 client
        _ MDS 9509

        Với những component như thế này chúng ta dễ dàng cung cấp các gói dịch vụ backup

       _ IP Backup: Giải pháp backup: từ Local Disk ra Tape cho 15 client khác nhau. Tuy
nhiên tốc độ sẽ chậm (Trung bình 1GB / 1 client / 16 minute)
       _ Storage Backup: Clone LUN hoặc Snapshot LUN bên trong CX

Hạn chế: Không có license cho việc backup database online (Vấn đề này có thể giải quyết khi
khách hàng có nhu cầu)
         Việc backup LUN phải làm thủ công, không có license cho việc lập Schedule không
monitor được quá trình

        3.1 Mô hình Serverless Backup

      MDS 9509 với Storage Service module (SSM) sẽ hỗ trợ tính năng serverless Backup để
nâng cao hiệu suất cho Tape Library: Sử dụng cho nhiều khách hàng khác nhau, tốc độ backup
cao hơn.




File Name   : Proposal SAN STEP by STEP.doc                           Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                       Page 12 of 16
3.2 Danh mục cần đầu tư
Product                  Description                                                    Price / Unit      Quantity
                                                                                        (USD)

MDS-SSM-32U              2Gb 32-Port FC Stg Sol Mod UPG (Storage Service                    40.000              1
                         Module) gắn trên MDS 9509
                         http://storagemojo.com/storagemojos-pricing-
                         guide/emc-price-list/

NETWORKER                Module powersnap (của Networker) cho phép đặt lịch                  3.000              1
POWERSNAP                đối với Snapview trong CX
MODULE 1TB
CAPACITY ( 456-
                         http://www.pcuniverse.com/product.asp?pid=3658183
005-405 )

Service                  Configure – Deploy SSM                                             15000




    4. PHASE 4: Tăng cường Security – Monitor – Multi Connecting
   Như đã giới thiệu về MDS 9509 là dòng sản phẩm Medium Director với điểm mạnh là Multi
VSAN và IVR – Inter VSAN Routing. Giúp tăng phần bảo mật dữ liệu, an toàn về hoạt động, và
nâng cao performance.

       Nếu như không sử dụng 02 tính năng này thì MDS cũng giống như các SAN Switch
bình thường khác.

          4.1 Security
         Enhanced security features:
            –    LUN zoning
            _    Read-only zones
         FC Port security
         VSAN-based access control
         Fibre Channel Security Protocol (FC-SP) authentication
         Advanced traffic engineering—quality of service (QoS)
         IP security (IPsec) protocol for iSCSI and FCIP using the MPS-14/2 module or Cisco MDS 9216i switch
         IPsec & IKE for IPv4
         IKE digital certificates
         Extended credits using the MPS-14/2 module or the Cisco MDS 9216i Switch
         Enhanced VSAN routing—inter-VSAN routing (IVR) over Fibre Channel
File Name   : Proposal SAN STEP by STEP.doc                                             Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                                         Page 13 of 16
   IVR Network Address Translation (NAT) over Fibre Channel
       Zone-based traffic prioritizing
       Zone-based FC QoS
       Extended BB_Credits
       Fibre Channel write acceleration
       SCSI flow statistics
       FCIP encryption
       Fabric binding for Fibre Channel
       SAN device virtualization
       Ingress port limiting

        4.2 Monitoring
       Centralized, Multiple physical fabric management
    •   Fabric discovery services
    •   Continuous MDS health and event monitoring
    •   Long term historical Fibre Channel performance monitoring and reporting
    •   Custom performance reports and charting for hotspot analysis
    •   Historical Performance Monitoring
    •   Performance prediction
    •   Performance threshold monitoring
    •   Fabric Manager Web Client for operational view
    •   Fabric Manager server proxy services
    •   Server performance summary report
    •   Configurable RRD collection parameters
    •   Data collection auto update
    •   Event forwarding
    •   Filtering by user-defined groups
    •   Custom Reports Enhancements
    •   Fabric Analysis Report
    •   Threshold Configuration Flexibility
    •   Web-based operational view
    •   Roaming User Profiles
    •   Traffic Analyzer for SCSI Flow Statistics




File Name   : Proposal SAN STEP by STEP.doc                                       Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                                   Page 14 of 16
4.3 Multi VSAN – IVR
Inter VSAN Routing

              Sharing Resources Across VSANs

       • Allows a device that is located in one VSAN to communicate with a device that is
located in another VSAN. IVR supports routing between all interop mode VSANs

       • Allows sharing of centralized resources such as tape and disks across VSANs –
without merging separate fabrics (VSANs).

        • Transparent to third-party switches

        • Enables blade-per-VSAN architecture for blade servers




      4.4 Danh mục cần đầu tư
Product        Description                                                   Price / Unit     Quantity
                                                                             (USD)

MDS-FMS-              License cho Fabric management                              15.000           1
9500                  http://www.neutronexpress.com/prod.cfm/635586/CL
                      ARION_DISK_ARRAYS/MDSFMS9500/SERVER
MDS-ENT-9500          ENTERPRISE LICCENSE KEY 9500 (Include IVR)                14.500            2
                      http://pc.pcconnection.com/1/1/71616-emc-enterprise-
                      license-key-9500-mds-ent-9500.html


File Name   : Proposal SAN STEP by STEP.doc                                  Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                              Page 15 of 16
Note: license list
http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a008
0662c89.html#wp10731




File Name   : Proposal SAN STEP by STEP.doc                         Author : Phạm Hồng Phước
Date        : 21-Oct-2008                                                     Page 16 of 16

More Related Content

Similar to Proposal san step by step

Hardware guide mx960
Hardware guide mx960Hardware guide mx960
Hardware guide mx960Huu Duc
 
He Thong IT Network Security
He Thong IT Network SecurityHe Thong IT Network Security
He Thong IT Network Security
Thanh Nguyen
 
Session Border Controller 12000
Session Border Controller 12000Session Border Controller 12000
Session Border Controller 12000
Long Nguyen
 
Data center
Data centerData center
Data centerVNG
 
Báo cáo thực tập tuần 6
Báo cáo thực tập tuần 6Báo cáo thực tập tuần 6
Báo cáo thực tập tuần 6
Quân Quạt Mo
 
Dsbd8800 s 1023
Dsbd8800 s 1023Dsbd8800 s 1023
Dsbd8800 s 1023
N-TEK Distribution
 
Cisco_VSS.pdf
Cisco_VSS.pdfCisco_VSS.pdf
Cisco_VSS.pdf
TrungNguyen335833
 
Vnpro bantindancisco34
Vnpro bantindancisco34Vnpro bantindancisco34
Vnpro bantindancisco34
PhmNgcTr3
 
Hp Blade Server
Hp Blade ServerHp Blade Server
Hp Blade Server
candinhviet
 
Server MDK.pptx
Server MDK.pptxServer MDK.pptx
Server MDK.pptx
son2483
 
Server MDK.pptx
Server MDK.pptxServer MDK.pptx
Server MDK.pptx
son2483
 
cấu hình cloudstack
cấu hình cloudstackcấu hình cloudstack
cấu hình cloudstack
vietbm9
 
Qo s trên windows
Qo s trên windows Qo s trên windows
Qo s trên windows Le Quyen
 
Tìm Hiểu WLAn, Giao Thức Radius, Mikrotik Router
Tìm Hiểu WLAn, Giao Thức Radius, Mikrotik RouterTìm Hiểu WLAn, Giao Thức Radius, Mikrotik Router
Tìm Hiểu WLAn, Giao Thức Radius, Mikrotik Router
Le Trung Hieu
 
Extreme networks Project
Extreme networks ProjectExtreme networks Project
Extreme networks Project
N-TEK Distribution
 
[123doc.vn] xay dung he thong mang cho doanh nhiep nho
[123doc.vn]   xay dung he thong mang cho doanh nhiep nho[123doc.vn]   xay dung he thong mang cho doanh nhiep nho
[123doc.vn] xay dung he thong mang cho doanh nhiep nhoNguyễn Quân
 
GIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNG
GIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNGGIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNG
GIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNG
PMC WEB
 
GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...
GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...
GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...
Đinh Công Thiện Taydo University
 
Cau hoi de tai
Cau hoi de taiCau hoi de tai
Cau hoi de taindtpro776
 

Similar to Proposal san step by step (20)

Hardware guide mx960
Hardware guide mx960Hardware guide mx960
Hardware guide mx960
 
He Thong IT Network Security
He Thong IT Network SecurityHe Thong IT Network Security
He Thong IT Network Security
 
Session Border Controller 12000
Session Border Controller 12000Session Border Controller 12000
Session Border Controller 12000
 
Data center
Data centerData center
Data center
 
Báo cáo thực tập tuần 6
Báo cáo thực tập tuần 6Báo cáo thực tập tuần 6
Báo cáo thực tập tuần 6
 
Dsbd8800 s 1023
Dsbd8800 s 1023Dsbd8800 s 1023
Dsbd8800 s 1023
 
Cisco_VSS.pdf
Cisco_VSS.pdfCisco_VSS.pdf
Cisco_VSS.pdf
 
Vnpro bantindancisco34
Vnpro bantindancisco34Vnpro bantindancisco34
Vnpro bantindancisco34
 
Hp Blade Server
Hp Blade ServerHp Blade Server
Hp Blade Server
 
Server MDK.pptx
Server MDK.pptxServer MDK.pptx
Server MDK.pptx
 
Server MDK.pptx
Server MDK.pptxServer MDK.pptx
Server MDK.pptx
 
cấu hình cloudstack
cấu hình cloudstackcấu hình cloudstack
cấu hình cloudstack
 
Qo s trên windows
Qo s trên windows Qo s trên windows
Qo s trên windows
 
Tìm Hiểu WLAn, Giao Thức Radius, Mikrotik Router
Tìm Hiểu WLAn, Giao Thức Radius, Mikrotik RouterTìm Hiểu WLAn, Giao Thức Radius, Mikrotik Router
Tìm Hiểu WLAn, Giao Thức Radius, Mikrotik Router
 
Baigiang Ns2
Baigiang Ns2Baigiang Ns2
Baigiang Ns2
 
Extreme networks Project
Extreme networks ProjectExtreme networks Project
Extreme networks Project
 
[123doc.vn] xay dung he thong mang cho doanh nhiep nho
[123doc.vn]   xay dung he thong mang cho doanh nhiep nho[123doc.vn]   xay dung he thong mang cho doanh nhiep nho
[123doc.vn] xay dung he thong mang cho doanh nhiep nho
 
GIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNG
GIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNGGIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNG
GIỚI THIỆU VỀ MÔ HÌNH ỨNG DỤNG MẠNG
 
GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...
GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...
GIAI TICH HE THONG DIEN NANG CAO - PHẦN KẾT GIỚI THIỆU PHẦN MỀM PHÂN BỐ CÔNG ...
 
Cau hoi de tai
Cau hoi de taiCau hoi de tai
Cau hoi de tai
 

Proposal san step by step

  • 1. PROPOSAL DEPLOY SAN at VINADATA STEP by STEP File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 1 of 16
  • 2. Contents 1. PHASE 1: Kích hoạt hệ thống SAN tại Cộng Hòa ............................................................... 3 1.1 Thiết bị hiện tại ............................................................................................................ 3 1.2 Mục tiêu ....................................................................................................................... 3 1.3 Danh mục cần đầu tư: .................................................................................................. 3 1.4 Mô hình đấu nối: .......................................................................................................... 4 2. PHASE 2: Disaster Recovery Site ....................................................................................... 5 2.1 Mục tiêu: ...................................................................................................................... 5 2.2 Mô hình kết nối ............................................................................................................ 5 2.2.1 Cơ chế hoạt động ................................................................................................. 6 2.2.2 Diễn giải kết nối .................................................................................................... 6 2.2.3 Chức năng MirrorView .......................................................................................... 7 Một số tình huống phục hồi ................................................................................................. 8 2.3 Lợi ích của giải pháp...................................................................................................11 2.4 Danh mục cần đầu tư .................................................................................................11 3. PHASE 3: NÂNG CẤP HỆ THỐNG BACKUP ....................................................................12 3.1 Mô hình Serverless Backup ........................................................................................12 3.2 Danh mục cần đầu tư .................................................................................................13 4. PHASE 4: Tăng cường Security – Monitor – Multi Connecting...........................................13 4.1 Security.......................................................................................................................13 4.2 Monitoring ...................................................................................................................14 4.3 Multi VSAN – IVR........................................................................................................15 4.4 Danh mục cần đầu tư ..................................................................................................15 File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 2 of 16
  • 3. 1. PHASE 1: Kích hoạt hệ thống SAN tại Cộng Hòa 1.1 Thiết bị hiện tại 01 Storage EMC CX3-40c: Dung lượng: FC HDD: 15 x 146Gb (10K rpm) FC HDD: 15 x 146Gb (15K rpm) SATAII HDD: 3 x 15 x 500Gb 02 Cisco MDS 9509 02 SAN Switch McDATA DS4700 01 Tape Library Quantum PX502 38 slot + 10 Tape LTO-3 (400Gb) 01 Software EMC Networker + license cho Autochanger Module, license cho 15 connection, license cho OS Linux 1.2 Mục tiêu _ Đưa hệ thống SAN vào hoạt động, có thể đáp ứng các nhu cầu SAN tại Site Cộng Hòa. _ Đưa hệ thống backup tape library vào họat động, trước mắt đáp ứng nhu cầu backup data cho VINADATA ‘s Office 1.3 Danh mục cần đầu tư: Gía STT Loại tài sản Số lượng Thành tiền Description (Price (No) (Sort of facilities) (Quantity) (Total USD) USD) Kết nối các port Management hệ thống SAN, Tape Library, MDS 9509, Networker Server 1 Switch Cisco 24 port http://www.overstock.com/Electro 01 ~ 4000 nics/Cisco-Catalyst-3560-Gigabit- Ethernet- Switch/2628347/product.html 3 HDD; Support PCI-E  Dùng làm 2 Server Server Backup (Control Tape 01 ~ 3000 Library) và SAN Management. http://www.shopping.com/xPP- 3 FC HBA LPe1150 network_adapters-- 01 ~ 800 ietf_ip_over_fc File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 3 of 16
  • 4. 1.4 Mô hình đấu nối: Tape Library PX502 HP Chassis Blade Server VSAN 1 ISL between 02 MDS MDS 9509 Networker Server (Control Tape Library) EMC CLARiiON CX3-40c _ Dùng 02 MDS 9509 để làm core của mạng SAN  tận dụng được các function và performance của MDS 9509. _ Reserved 02 SAN Switch DS4700 cho các nhu cầu kết nối Site to Site với các khách hàng khác. File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 4 of 16
  • 5. 2. PHASE 2: Disaster Recovery Site 2.1 Mục tiêu: _ Tăng cường tính an toàn về mặt data và Service _ Thêm 1 offer Disaster Recovery Site + Backup cho khách hàng _ Data của Khách hàng có thể đặt server tại Công Hòa, backup ra Tape, Replicate data trên SAN tại site Điện Biên Phủ. Và ngược lại _ Ngoài việc offer cho khách hàng dịch vụ redundancy về Data, ta có thể offer thêm redundancy service (2 hệ thống Mail Server đặt tại 02 site, 1 Active 1 Stanby với 02 hệ thống Database được replicate giữa 02 site). 2.2 Mô hình kết nối File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 5 of 16
  • 6. 2.2.1 Cơ chế hoạt động Giải pháp kết nối và DR được xây dựng dựa trên việc kéo dài mạng SAN thông qua Black Fiber (FC Single Mode) - với 02 SAN Switch DS-4700 tại mỗi site làm core – từ Production Site (20bis Cộng Hòa) và Disaster Recovery Site (381 Điện Biên Phủ) kết hợp với giải pháp nhân bản dữ liệu đối xứng sử dụng phần mềm MirroView/S chạy trên hệ thống CLARiiON CX3 của EMC. Đường cáp quang sử dụng là 02 đường Dark Fibre với tốc độ 2Gb/s. Hai cổng trên hai thiết bị lưu trữ CX3-40c và CX3-40 trên hai SP (Storage Processor) sẽ được zoning trong cùng một zone, hai thiết bị lưu trữ sẽ cùng trên một domain. Kết nối từ lưu trữ đến patch panel sẽ sử dụng cáp multi mode chuẩn LC-LC. Phần mềm nhân bản đồng bộ MirrorView/S sẽ được cài đặt trên cả 2 site đảm bảo đồng bộ dữ liệu giữa hai trung tâm cũng như phục vụ cho giải pháp phục hồi thảm họa (Disarter Recovery). Bên cạnh đó, với mô hình được thiết kế ở trên, trung tâm dữ liệu chính của VINADATA tại đường Cộng Hòa sẽ sử dụng 02 Director MDS 9509 của Cisco để phân chia mạng SAN kết nối của các server (thuộc các project khác nhau) tại Production Site thành các VSAN, các MDS như đã biết sẽ đóng vai trò là các Core Switch. Giữa các Switch sẽ sử dụng kết nối ISL (Inter Switch Links).Trong tương lai, trung tâm dữ liệu chính tại đường Cộng Hòa của VINADATA sẽ có thêm rất nhiều SAN Switch với rất nhiều cổng kêt nối, việc sử dụng VSAN sẽ làm cho mô hình quản trị rõ ràng tách bạch, giúp cho việc quản lý trở nên dễ dàng hơn, bảo mật hơn 2.2.2 Diễn giải kết nối Kết nối 02 hệ thống CX3 thông qua 02 đường Dark Fiber sẽ được join vào cùng 1 domain, Mirror View Zone làm nhiệm vụ đường replicate/mirror data giữa 02 site. Tại DR Site các server sẽ được configure Zoning với các LUN trên CX3-40 thông qua SAN switch DS-4700 hoặc iSCSI Router (iSCSI SAN). Đảm bảo mỗi server connect đến CX3-40 với 04 path Tại Production Site các server kết nối đến CX3-40c thông qua MDS 9509 phân ra thành nhiều VSAN khác nhau để quản trị rõ ràng cũng như thêm phần bảo mật. File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 6 of 16
  • 7. 2.2.3 Chức năng MirrorView Sau khi thiết lập mối quan hệ nhân bản dữ liệu giữa hai hệ thống CLARiiON, MirrorView/S sẽ đảm bảo bảo vệ toàn bộ dữ liệu của hệ thống thứ nhất. Sau lần synchronize đầu tiên, toàn bộ dữ liệu trên hệ thống CX3-40C tại trung tâm chính cần được bảo vệ sẽ được MirrorView nhân bản sang hệ thống CX3-40C dự phòng. Source Target 1 2 Limited distance 4 3  Lệnh ghi được ghi vào cache của CLARiiON tại trung tâm chính  Lệnh ghi được chuyển qua đường kết nối FC và ghi vào cache của hệ thống CLARiiON tại trung tâm dự phòng  CLARiiON dự phòng ghi nhận là đã ghi xong dữ liệu  CLARiiON chính ghi nhận với ứng dụng là đã ghi xong dữ liệu Như vậy, trong trường hợp bình thường, toàn bộ dữ liệu cần bảo vệ ở trung tâm chính sẽ được nhân bản sang trung tâm dự phòng Trong trường hợp đường kết nối bị đứt, CLARiiON sẽ lưu trữ một bảng chứa các block đã bị thay đổi kể từ khi đường kết nối bị đứt. Khi đường kết nối hoạt động trở lại, các block bị thay đổi sẽ được copy sang hệ thống dự phòng. Hệ thống hoạt động hoàn toàn ở mức thiết bị lưu trữ và không phụ thuộc vào máy chủ, hệ điều hành và ứng dụng và cũng không đòi hỏi sự sẵn có của các hệ thống này vẫn bảo vệ được dữ liệu. CLARiiON là sản phẩm duy nhất của dòng tầm trung cho đồng bộ dữ liệu từ trung tâm dự phòng về trung tâm chính theo cơ chế incremental, rút ngắn quá trình đồng bộ dữ liệu (xuống còn khoảng vài chục phút tới vài giờ thay vì hàng ngày nếu phải đồng bộ 100% dữ liệu) File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 7 of 16
  • 8. Một số tình huống phục hồi Ổ đĩa tại trung tâm dữ liệu chính lỗi Nếu ổ đĩa chứa dữ liệu tại trung tâm dữ liệu chính bị lỗi, các lệnh I/O sẽ bị từ chối cho đến khi ổ đĩa đó được phục hồi lại. Trong quá trình này, người dùng có thể nâng cấp ổ đĩa tại trung tâm dự phòng thành ổ đĩa chính và chuyển các lệnh I/O đến ổ đĩa này. Các truy xuất vẫn được thực hiện bằng máy chủ ở trung tâm chính thông qua đường cáp quang tới ổ đĩa ở trung tâm dự phòng. Điều này giúp biến bản sao ở trung tâm dự phòng thành một bản sao ánh xạ (mirror) thực sự. Bộ xử lý lưu trữ (SP) điều khiển các ổ đĩa chính lỗi Nếu bộ xử lý lưu trữ quản lý một ổ đĩa bị lỗi, thì MirrorView sẽ chuyển quyền quản lý sang bộ xử lý lưu trữ khác cùng trên một dãy đĩa. Khi lỗi này xảy ra trên hệ thống lưu trữ chính, một message được gửi đến hệ thống lưu trữ dự phòng để hệ thống lưu trữ dự phòng cũng sẽ chuyển quyền quản lý ổ đĩa nhân bản sang bộ xử lý lưu trữ tương ứng. Nếu dữ liệu tại trung tâm dự phòng bị gián đoạn, dữ liệu từ Write Intent Log được dùng để đồng bộ lại khi hệ thống làm việc bình thường. Trước khi bộ xử lý lưu trữ gặp lỗi: Cả hai ổ cứng logic (LUN) trên hai dãy đĩa đều được điều khiển bởi Bộ xử lý lưu trữ A (SP A) File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 8 of 16
  • 9. Khi xảy ra lỗi với bộ xử lý lưu trữ A: Các ổ đĩa được chuyển sang quản lý bởi bộ xử lý lưu trữ B (SP B) Hệ thống lưu trữ chính bị lỗi Nếu hệ thống lưu trữ chính chứa ổ đĩa chính bị lỗi, các lệnh đọc ghi của máy chủ (I/O) được ngừng lại cho đến khi hệ thống lưu trữ được phục hồi. Cũng giống như ổ đĩa logic (LUN) chính bị lỗi, người sử dụng có thể chọn cách nâng cấp hệ thống lưu trữ dự phòng lên thành hệ thống chính và chuyển các lệnh đọc ghi của máy chủ sang hệ thống này. File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 9 of 16
  • 10. Trước khi hệ thống lưu trữ chính gặp lỗi: Ổ đĩa chính (trên dãy đĩa CLARiiON chính) có Mirror ID là X Sau khi có lỗi đối với hệ thống lưu trữ chính: Ổ đĩa chính vừa được nâng quyền (trên dãy đĩa dự phòng CLARiiON ) có Mirror ID là Y Trung tâm dự phòng có lỗi và cách phục hồi Khi trung tâm dự phòng gặp lỗi đương nhiên sẽ giảm khả năng dư thừa dự phòng hoặc không thể truy cập dữ liệu từ trung tâm chính đến trung tâm dự phòng. Ổ đĩa dự phòng (LUN) lỗi Nếu ổ đĩa vật lý dự phòng tại trung tâm dự phòng bị lỗi, người quản trị có thể chọn hoặc sửa ổ đĩa đó hoặc gỡ bỏ ra khỏi mỗi quan hệ với các ổ đĩa Mirror khác. Nếu ổ đĩa được phục hồi, nó phải được đồng bộ lại. Nếu ổ đĩa khác được chọn làm ổ đĩa dự phòng, ổ đĩa đó phải được đồng bộ hoàn toàn. Bộ xử lý lưu trữ (SP) điều khiển các ổ đĩa dự phòng lỗi Nếu bộ xử lý điều khiển một ổ đĩa tại trung tâm dự phòng gặp lỗi, hệ thống sẽ dừng lại cho đến khi bộ xử lý đó được phục hồi. Khi bộ xử lý được phục hồi, dữ liệu nhân bản sẽ tự động đồng bộ. File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 10 of 16
  • 11. 2.3 Lợi ích của giải pháp Ngoài những lợi ích đã trình bày ở trên, thì còn có lợi ích về mặt đầu tư thiết bị. Nếu như chúng ta muốn sử dụng MDS 9509 dùng làm core kết nối site to site, chúng ta cần đầu tư thêm software va hardware cho MDS: _ License Extension SAN: Price: $10.000 x 2. http://www.pcconnection.com/IPA/Shop/Product/Detail.htm?sku=8078486 _ Module support transceiver Longwave 10km (DS-X9124): Price: €14,429 x 2 http://www.pcwb.ie/catalogue/item/CISMDS06 2.4 Danh mục cần đầu tư Số lượng Gía STT Loại tài sản Thành tiền Description (Quantity (Price (No) (Sort of facilities) (Total USD) USD) USD) Cable single mode 1 FC Cable 06 65 390 LC-LC duplex 30m Cable single mode 2 FC Cable 04 40 160 LC-LC duplex 8m Cable Multi mode 3 50/125 SC-LC duplex FC Cable 15 40 600 8m Cable Multi mode 4 50/125 SC-LC duplex FC Cable 4 50 200 16m Cable Multi mode 6 50/125 SC-SC duplex FC Cable 12 40 480 8m Module Long Wave Long Wave Optic KIT-10Km 7 (DSED-LWKT10) www.peppm.org/Products/emc 04 240 960 hardware/price.pdf MIRRORVIEW SYNC CX3-40 License Mirror View/S http://computer.pwgsc.gc.ca/ht 8 02 15000 30000 (MVS34) docs/storage/sannas/vendors/ emc/san1b.pdf _ Tư vấn thiết kế DR _ Cài đặt Mirror View tại 02 site _ Cấu hình đồng bộ dữ liệu 9 Service 10000 _ Training 02 ngày _ Maintenance System 02 tháng File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 11 of 16
  • 12. 3. PHASE 3: NÂNG CẤP HỆ THỐNG BACKUP Hiện tại chúng ta có: _Tape Library PX502 (1 Drive – 36 slot – 10 tape) _ EMC Networker (phần mềm Backup) + License cho PX502 + License cho việc backup từ môi trường Linux + License cho 15 client _ MDS 9509 Với những component như thế này chúng ta dễ dàng cung cấp các gói dịch vụ backup _ IP Backup: Giải pháp backup: từ Local Disk ra Tape cho 15 client khác nhau. Tuy nhiên tốc độ sẽ chậm (Trung bình 1GB / 1 client / 16 minute) _ Storage Backup: Clone LUN hoặc Snapshot LUN bên trong CX Hạn chế: Không có license cho việc backup database online (Vấn đề này có thể giải quyết khi khách hàng có nhu cầu) Việc backup LUN phải làm thủ công, không có license cho việc lập Schedule không monitor được quá trình 3.1 Mô hình Serverless Backup MDS 9509 với Storage Service module (SSM) sẽ hỗ trợ tính năng serverless Backup để nâng cao hiệu suất cho Tape Library: Sử dụng cho nhiều khách hàng khác nhau, tốc độ backup cao hơn. File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 12 of 16
  • 13. 3.2 Danh mục cần đầu tư Product Description Price / Unit Quantity (USD) MDS-SSM-32U 2Gb 32-Port FC Stg Sol Mod UPG (Storage Service 40.000 1 Module) gắn trên MDS 9509 http://storagemojo.com/storagemojos-pricing- guide/emc-price-list/ NETWORKER Module powersnap (của Networker) cho phép đặt lịch 3.000 1 POWERSNAP đối với Snapview trong CX MODULE 1TB CAPACITY ( 456- http://www.pcuniverse.com/product.asp?pid=3658183 005-405 ) Service Configure – Deploy SSM 15000 4. PHASE 4: Tăng cường Security – Monitor – Multi Connecting Như đã giới thiệu về MDS 9509 là dòng sản phẩm Medium Director với điểm mạnh là Multi VSAN và IVR – Inter VSAN Routing. Giúp tăng phần bảo mật dữ liệu, an toàn về hoạt động, và nâng cao performance. Nếu như không sử dụng 02 tính năng này thì MDS cũng giống như các SAN Switch bình thường khác. 4.1 Security  Enhanced security features: – LUN zoning _ Read-only zones  FC Port security  VSAN-based access control  Fibre Channel Security Protocol (FC-SP) authentication  Advanced traffic engineering—quality of service (QoS)  IP security (IPsec) protocol for iSCSI and FCIP using the MPS-14/2 module or Cisco MDS 9216i switch  IPsec & IKE for IPv4  IKE digital certificates  Extended credits using the MPS-14/2 module or the Cisco MDS 9216i Switch  Enhanced VSAN routing—inter-VSAN routing (IVR) over Fibre Channel File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 13 of 16
  • 14. IVR Network Address Translation (NAT) over Fibre Channel  Zone-based traffic prioritizing  Zone-based FC QoS  Extended BB_Credits  Fibre Channel write acceleration  SCSI flow statistics  FCIP encryption  Fabric binding for Fibre Channel  SAN device virtualization  Ingress port limiting 4.2 Monitoring  Centralized, Multiple physical fabric management • Fabric discovery services • Continuous MDS health and event monitoring • Long term historical Fibre Channel performance monitoring and reporting • Custom performance reports and charting for hotspot analysis • Historical Performance Monitoring • Performance prediction • Performance threshold monitoring • Fabric Manager Web Client for operational view • Fabric Manager server proxy services • Server performance summary report • Configurable RRD collection parameters • Data collection auto update • Event forwarding • Filtering by user-defined groups • Custom Reports Enhancements • Fabric Analysis Report • Threshold Configuration Flexibility • Web-based operational view • Roaming User Profiles • Traffic Analyzer for SCSI Flow Statistics File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 14 of 16
  • 15. 4.3 Multi VSAN – IVR Inter VSAN Routing Sharing Resources Across VSANs • Allows a device that is located in one VSAN to communicate with a device that is located in another VSAN. IVR supports routing between all interop mode VSANs • Allows sharing of centralized resources such as tape and disks across VSANs – without merging separate fabrics (VSANs). • Transparent to third-party switches • Enables blade-per-VSAN architecture for blade servers 4.4 Danh mục cần đầu tư Product Description Price / Unit Quantity (USD) MDS-FMS- License cho Fabric management 15.000 1 9500 http://www.neutronexpress.com/prod.cfm/635586/CL ARION_DISK_ARRAYS/MDSFMS9500/SERVER MDS-ENT-9500 ENTERPRISE LICCENSE KEY 9500 (Include IVR) 14.500 2 http://pc.pcconnection.com/1/1/71616-emc-enterprise- license-key-9500-mds-ent-9500.html File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 15 of 16
  • 16. Note: license list http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a008 0662c89.html#wp10731 File Name : Proposal SAN STEP by STEP.doc Author : Phạm Hồng Phước Date : 21-Oct-2008 Page 16 of 16