Mercy Hospital Solar Project 25.5kW 1) Panel Data
Mercy Hospital Solar Project 25.5kW
LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM [HANWHA
Q . C E L L S GMBH]	
  
	
  
Dear Customer,
You have made an excellent choice in purchasing quality modules from [Hanwha Q.CELLS GmbH] (“Q CELLS”). The photovoltaic
modules you have purchased have been manufactured with great care and have undergone a final functional test. We also
provide the following limited warranty (“Warranty”):
SCOPE
This Warranty applies exclusively to Q CELLS photovoltaic
modules of the following types (the “Modules”):
• Q.PEAK G2
• Q.PEAK G3
• Q.PEAK BLK G2
• Q.PEAK BLK G3
• Q.PRO G2
• Q.PRO G3
• Q.PRO L
All Modules must be sold and installed within the United States
and bear our manufacturer‘s label to be eligible for this Warranty.
Warrantor is Hanwha Q.CELLS GmbH, OT Thalheim, Sonnenallee
17-21, 06766 Bitterfeld-Wolfen, Germany.
The applicable Warranty period begins on the date of the initial
purchase of the Modules by the original end customer as set forth
in the applicable invoice (the “Purchase Date”).
12-YEAR PRODUCT WARRANTY
Q CELLS warrants to you that Modules which are installed in
accordance with the applicable installation and operation manual
and other product documentation provided to customers by
Q CELLS for the Modules (collectively, “Product Instructions”) will
not show any defects in materials or workmanship for a period of
twelve years after the applicable Purchase Date. In the event that
a Module has any such defect covered by this warranty (case of
warranty), Q CELLS, at its choice, will either repair the defect or
supply a replacement Module. If Q CELLS is unable to repair the
defect or supply a replacement Module, Q CELLS will have the
right to refund you the prorated value of the purchase price paid by
you to Q CELLS or Q CELLS’ authorized reseller for the affected
Modules (“Purchase Price”), provided that you first return to
Q CELLS the affected Module. The foregoing constitutes your sole
and exclusive remedy for a breach of the warranty set forth in this
paragraph (the “Product Warranty”).
25-YEAR LINEAR PERFORMANCE WARRANTY
In addition, Q CELLS provides you the following performance
warranty (“Performance Warranty”) for Modules which are installed
in accordance with the applicable Product Instructions:
In the first year after the Purchase Date the Modules will produce
a minimum power output of at least 97 % of that specified in the
Module data sheet. From a period beginning on the first
anniversary of the Purchase Date and ending on the twenty-fifth
anniversary of the Purchase Date, the Modules will have a yearly
maximum decrease of power output (degradation) of not more
than 0.6 % of the power output specified in the Module data sheet
within the framework of the power tolerance, i.e. the Module will
have a minimum power output of at least 83 % of the power output
specified in the Module data sheet at the end of the twenty-five
year period.
All power output measurements will be performed under the STC
Standard Test Conditions used by Q CELLS on the Purchase
Date. The STC Standard Test Conditions are customary
standardized basic conditions for the measurement of the power of
solar modules. The currently valid STC Standard Test Conditions
are defined in the IEC standards EN 61215 and 60904-3.
In the event of a breach of this Performance Warranty, Q CELLS
will, at its choice, repair the defect, replace the affected Module,
supply additional modules sufficient to make up for the power
output reduction, refund you the full Purchase Price of the affected
Module provided that you first return to Q CELLS the affected
Module, or refund you a percentage of the Purchase Price of the
affected Module equal to the percentage reduction in minimum
power output compared to the minimum power output warranted
under this Performance Warranty. The foregoing constitutes your
sole and exclusive remedy for a breach of this Performance
Warranty.
EXCLUSIONS FROM THE PRODUCT AND PERFORMANCE
WARRANTY
Irrespective of contributory root causes, this Warranty does not
cover the following cases:
• Handling, storage, installation, configuration, testing, or use not
in accordance with the Product Instructions (e.g., static,
installation of mutually incompatible modules, inadequate
system design, and incompatible inverter);
• Repair, servicing or maintenance work not in accordance with
the Product Instructions or failure to perform maintenance as
required by the Product Instructions.
• Usage in an environment outside the parameters specified in
the Product Instructions, including without limitation high snow
load outside such parameters;
• Usage for purposes or in circumstances not conforming to the
product specifications (as set out in the module data sheet
applicable to the modules in any given case) and not complying
with the installation and operating instructions;
• Damage caused by environmental sources, such as but not
limited to pollution of any kind as well as fire, explosion, smoke
or charring;
• Damage caused by acts of nature or God, including without
limitation lightning, hail, frost, snow, or storms;
• Damage caused by abuse, negligence, neglect, or accident,
including without limitation acts of violence and vandalism
• Damages to the photovoltaic system in which the Modules are
installed, or damages caused by factors such as voltage
fluctuations, power peaks, excess voltage, power failure etc.;
• Scratches, marks, mechanical wear, rust, mold, degradation,
dis-coloration and other changes which occur after the delivery
of the Modules but which do not result in any adverse effect on
the mechanical stability of the Module or a reduction of
performance which exceeds the levels set out in the
Performance Warranty; and
• Issues not reproducible by Q CELLS.
The following cases are also excluded from the Warranty:
• The Q CELLS Modules are modified or altered or used in
processes involving other products without obtaining prior
written consent from Q CELLS.
• The serial number or product label has been removed,
changed, deleted or made unrecognizable or if it is no longer
clearly distinguishable for other reasons beyond Q CELLS’
control and therefore it is not possible to conclusively identify
the Modules.
Use on mobile carriers such as motor vehicles or ships. As part of
the warranty there is no claim to compensation for the
Mercy Hospital Solar Project 25.5kW
2) Panel Warranty
LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM [HANWHA
Q . C E L L S GMBH]	
  
	
  
reimbursement of costs for dismantling, installation or
replacement, loss of yield or other indirect damages.
CLAIMS UNDER WARRANTY/NOTIFICATION OF DEFECTS
You must check the Modules for visible defects upon delivery. If
you discover any defects, you must report these immediately to
Q CELLS.
You must report any Warranty claim to Q CELLS during the
applicable Warranty period and no later than thirty (30) days after
discovering the breach of Warranty.
Please contact us first in writing or electronically. Contact
information, the required data and the procedure of the complaint
process are described in document Q CELLS’ RMA process
(Return Merchandise Authorization). You must follow the RMA
process to be eligible for Warranty service.
If you have any questions please contact your seller or Q CELLS
at the following e-mail address: service@q-cells.com.
We ask for our customers’ understanding that Q CELLS cannot
accept any unauthorized return shipments of Modules and will not
take delivery of such items.
PERFORMANCE OF THE WARRANTY SERVICES
In all cases, Q CELLS shall have the choice in accordance with
this Warranty as to how Warranty claims are settled. Q CELLS
may use the services of a third party service partner for this
purpose.
• Q CELLS shall pay the costs of a technical inspection of the
affected Module in case of a Warranty claim. If there is no
breach of Warranty as reasonably determined by Q CELLS, you
will pay these costs
• Q CELLS shall only accept liability under the performance
warranty if the performance parameters measured by Q CELLS
in the STCs (Standard Test Conditions) are not achieved.
• The returned Modules shall remain your property unless
Q CELLS chooses to replace such Modules, in which case
ownership of the replaced Modules passes to Q CELLS.
• Any repaired or replaced Modules shall be covered by the
Warranty for the remaining portion of the original Warranty
period as applicable.
• If Q CELLS supplies replacement or additional modules under
this Warranty and the original Module type is no longer
available, Q CELLS will have the right to provide replacement or
additional modules of a similar or equivalent type from the
product range available at the time of the claim as long as they
are suitable for the intended purpose.
• In the event of glass breakage, Q CELLS reserves the right to
perform a static calculation to verify the substructure was
designed in accordance with the Product Instructions.
• Q CELLS will have no liability in connection with this Warranty
for any costs or expenses of dismantling or installing Modules or
replacement modules.
DISCLAIMER
EXCEPT AS EXPRESSLY SET FORTH IN THE PRODUCT
WARRANTY AND THE PERFORMANCE WARRANTY, Q CELLS
HEREBY DISCLAIMS ALL WARRANTIES, WHETHER
EXPRESS, IMPLIED, OR STATUTORY, REGARDING THE
MODULES, INCLUDING WITHOUT LIMITATION ANY
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT OF
THIRD-PARTY RIGHTS, AND SYSTEM INTEGRATION.
LIMITATION OF LIABILITY
Q CELLS WILL NOT BE LIABLE FOR ANY CONSEQUENTIAL,
EXEMPLARY, SPECIAL, INDIRECT, OR INCIDENTAL
DAMAGES, INCLUDING ANY DAMAGES FOR LOST PROFITS
OR LOSS OF YIELD, ARISING FROM OR RELATING TO THIS
WARRANTY OR THE MODULES, EVEN IF Q CELLS KNEW OR
SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH
DAMAGES. Q CELLS’ TOTAL CUMULATIVE LIABILITY
ARISING FROM OR RELATED TO THIS WARRANTY AND THE
MODULES, WHETHER IN CONTRACT OR TORT OR
OTHERWISE, WILL NOT EXCEED THE PRODUCT PRICE FOR
THE MODULE(S) AT ISSUE. THE FOREGOING LIMITATIONS
OF LIABILITY ARE INDEPENDENT OF EXCLUSIVE REMEDIES
FOR BREACH OF THIS WARRANTY. Q CELLS DISCLAIMS
ALL LIABILITY OF ANY KIND OF Q CELLS’ SUPPLIERS UNDER
THIS AGREEMENT.
SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED
WARRANTIES OR THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO
YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE. THE DISCLAIMERS, EXCLUSIONS,
AND LIMITATIONS OF LIABILITY UNDER THIS WARRANTY
WILL NOT APPLY TO THE EXTENT PROHIBITED BY
APPLICABLE LAW.
ASSIGNMENT OF WARRANTY FOR PV MODULES
This Warranty for PV Modules in its entirety, extends only to the
original purchaser, and is transferrable in its entirety to any other
person to whom title to the PV Modules has been transferred
provided that a) a prior written notice of such transfer has been
received by Q CELLS, and b) the PV Modules remain installed in
their original installation location.
GOVERNING LAW
These Warranty terms and conditions shall be exclusively
governed by the laws of the State of California, without giving
effect to any conflict of laws principles that would require the
application of the laws of another State laws principles that would
require the application of the laws of another State.
Mercy Hospital Solar Project 25.5kW
STP12000Tl-US-10/STP15000Tl-US-10/STP20000Tl-US-10/STP24000TL-US-10
Design flexibility
•	1000 V DC or 600 V DC
•	Two independent DC inputs
•	15° to 90° mounting angle range
•	Detachable DC Connection Unit
System efficiency
•	98% CEC, 98.5% Peak
•	1000 V DC increases system
efficiency
•	OptiTrac advanced MPPT
•	OptiTrac Global Peak MPPT
Enhanced safety
•	Integrated DC AFCI
•	Floating system with all-pole
sensitive ground fault protection
•	Reverse polarity indicator
Future-proof
•	Cluster Controller, WebConnect/
Speedwire
•	Bi-directional Ethernet communications
•	Complete grid management feature set
•	Ability to satisfy future utility requirements
Sunny Tripower
12000TL-US / 15000TL-US / 20000TL-US / 24000TL-US
The ultimate solution for decentralized PV plants
SMA’s new Sunny Tripower TL-US is raising the level of performance for decentralized commercial PV plants. This three-phase
transformerless inverter is UL listed for up to 1000 V DC maximum system voltage and has peak efficiency above 98 percent,
while OptiTrac Global Peak minimizes the effects of shade for maximum energy production. The Sunny Tripower delivers a
future-proof solution with full grid management, and communications and monitoring features. The Sunny Tripower is also
equipped with all-pole ground fault protection and integrated AFCI for a safe, reliable solution. It offers unmatched flexibility
with a wide input voltage range and two independent MPP trackers. Suitable for both 600 V DC and 1,000 V DC applica-
tions, the Sunny Tripower allows for flexible design and a lower levelized cost of energy.
SUNNY TRIPOWER
12000Tl-US / 15000Tl-US / 20000Tl-US / 24000TL-US
Mercy Hospital Solar Project 25.5kW 3) Inverter Data
Enhanced power production
Leading efficiency and SMA’s proprietary
OptiTrac Global Peak MPP tracking
means owners benefit from superior power
production and improved economics. When
operated at 1,000 V DC, balance of system
costs can also be significantly reduced.
The Sunny Tripower TL-US also features
advanced diagnostics, including a reverse
polarity indicator via the Connection Unit
1000-US.
Future proof
The Sunny Tripower TL-US includes a
number of technologies designed to
meet tomorrow’s requirements. Full grid
management functionality is available, as
are cutting edge communication options like
SMA’s Cluster Controller and Speedwire.
SMA Service can also simplify long-term
planning with comprehensive packages
covering inverters through plant-wide
operations and maintenance (O&M). And,
as a decentralized technology, inverter-
level O&M is reduced from the beginning
compared to centralized architecture.
Optimized cost
The Sunny Tripower TL-US allows integrators
to optimally use real estate, shorten design
and installation time, and produce more
power. Inverter-level O&M is reduced
through string technology and long-term
support is made simple through SMA’s
service organization, making the Sunny
Tripower TL-US the ultimate solution for
decentralized PV.
The Sunny Tripower TL-US is engineered to
optimize design, production, and reliability—
reducing a project’s levelized cost of energy
and improving its financial returns.
Unmatched flexibility
Available in four power classes, the Sunny
Tripower TL-US features a wide operating
window, two MPP trackers, and 600 V
DC or 1,000 V DC operation, making it
ideal for any decentralized project. System
engineering is made simple and repeatable,
resulting in a shortened design cycle.
Easy to transport and install, the Sunny
Tripower can be mounted in a variety of
ways from vertical to nearly horizontal.
Concrete pads usually required by central
inverters are unnecessary, preserving site
real estate.
THE TOTAL PACKAGE
Mercy Hospital Solar Project 25.5kW
Technical data
Sunny Tripower
12000TL-US
Sunny Tripower
15000TL-US
Sunny Tripower
20000TL-US
Sunny Tripower
24000TL-US
Input (DC)
Max. recommended PV power (@ module STC) 15000 W 18750 W 25000 W 30000 W
Max. DC voltage* 1000 V 1000 V 1000 V 1000 V
Rated MPPT voltage range 300 V…800 V 300 V…800 V 380 V…800 V 450 V…800 V
MPPT operating voltage range 150 V…1000 V 150 V…1000 V 150 V…1000 V 150 V…1000 V
Min. DC voltage / start voltage 150 V / 188 V 150 V / 188 V 150 V / 188 V 150 V / 188 V
Number of MPP tracker inputs 2 2 2 2
Max. input current / per MPP tracker input 66 A / 33 A 66 A / 33 A 66 A / 33 A 66 A / 33 A
Output (AC)
AC nominal power 12000 W 15000 W 20000 W 24000 W
Max. AC apparent power 12000 VA 15000 VA 20000 VA 24000 VA
Output phases / line connections 3 / 3-N-PE
Nominal AC voltage 480 / 277 V WYE
AC voltage range 244 V…305 V
Rated AC grid frequency 60 Hz
AC grid frequency / range 50 Hz, 60 Hz / 44 Hz…65 Hz
Max. output current 14.4 A 18 A 24 A 29 A
Power factor at rated power / adjustable displacement 1 / 0.8 leading…0.8 lagging
Harmonics < 3 %
Efficiency
Max. efficiency 98.2 % 98.2 % 98.5 % 98.5 %
CEC efficiency 97.5% 97.5% 97.5% 98.0%
Protection devices
DC reverse polarity protection ● ● ● ●
Ground fault monitoring / Grid monitoring ● ● ● ●
All-pole sensitive residual current monitoring unit ● ● ● ●
DC AFCI compliant to UL 1699B ● ● ● ●
AC short circuit protection ● ● ● ●
Protection class / overvoltage category I / IV I / IV I / IV I / IV
General data
Dimensions (W / H / D) in mm (in) 665 / 690 / 265 (26.1 / 27.1 / 10.4)
Packing dimensions (W / H / D) in mm (in) 780 / 790 / 380 (30.7 / 31.1 / 15.0)
Weight 55 kg (121 lbs)
Packing weight 61 kg (134.5 lbs)
Operating temperature range -25°C...+60°C
Noise emission (typical) 51 dB(A)
Internal consumption at night 1 W
Topology Transformerless
Cooling concept OptiCool
Electronics protection rating NEMA 3R
Features
Display / LED indicators (Status / Fault / Communication) ̶ / ● ̶ / ● ̶ / ● ̶ / ●
Interfaces: Speedwire / RS485 ●/○ ●/○ ●/○ ●/○
Mounting Angle Range 15°…90° 15°…90° 15°…90° 15°…90°
Warranty: 10 / 15 / 20 years ●/○/○ ●/○/○ ●/○/○ ●/○/○
Certifications and approvals (pending) UL1741,UL1998,UL1699B,IEEE1547,FCCPart15(ClassA&B),CAN/CSAC22.2107.1-1
NOTE: US inverters ship with gray lids
*Suitable for 600 V DC max. systems
Type designation STP 12000TL-US-10 STP 15000TL-US-10 STP 20000TL-US-10 STP 24000TL-US-10
Accessories
● Standard features  ○ Optional features  — Not available
Data at nominal conditions
RS485 interface
DM-485CB-US-10
SMA Cluster Controller
CLCON-10
Mercy Hospital Solar Project 25.5kW
Mercy Hospital Solar Project 25.5kW 4) Inverter Warranty
Mercy Hospital Solar Project 25.5kW
Mercy Hospital Solar Project 25.5kW
Product Data Sheet H362NRB
Safety Switch , Fusible, 600V, 3-Pole
List Price $1,134.00 USD
Availability Stock Item: This item is normally stocked in our distribution facility.
Disconnect Type Fusible
Depth 6.38 Inches
Enclosure Rating NEMA 3R
Maximum Voltage Rating 600V
Height 17.50 Inches
Short Circuit Current Rating 10kA (Class H or K) - 200kA (Class R,J or L)
Enclosure Type Rainproof and Sleet/Ice proof (Indoor/Outdoor)
Width 9.00 Inches
Action Single Throw
Mounting Type Surface
Ampere Rating 60A
Enclosure Material Galvannealed Steel
Number of Poles 3-Pole
Approvals UL Listed
Factory Installed Neutral Yes
Terminal Type Lugs
Wire Size #12 to #2 AWG(Al) or #14 to #2 AWG(Cu)
Electrical Interlock None
Type of Duty Heavy Duty
Technical Characteristics
Category 00009 - Safety Switch, Heavy Duty, 2 & 3 Pole, 30-200 Amp, Outdoor
Discount Schedule DE1
GTIN 00785901122494
Package Quantity 1
Weight 15.35 lbs.
Availability Code Stock Item: This item is normally stocked in our distribution facility.
Returnability Y
Country of Origin US
Shipping and Ordering
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.
Generated: 05/06/2010 14:48:24
© 2010 Schneider Electric. All rights reserved. 1
Mercy Hospital Solar Project 25.5kW
5) Disconnect Data
… the unbeatable aerodynamic flat-roof solution
Our aerocompact s® (south oriented), is the aerodynamic
solution for mounting framed modules on flat roofs. This system
offers the best value for your money and has excellent installation
features.
With aerocompact s® an assembly time of 10 minutes per kWp
can be reached.
The system is wind-tunnel tested, conforms to UL 2703 certification
and is delivered pre-assembled with protection mats incl. Aluminum
coating to prevent diffusion of the plastic softener. You will also re-
ceive a free ballast calculation incl. roof layout and a project specific
static report, from our unique online software „Aerotool“.
aerocompact® „the unbeatable aerodynamic flat-roof solution“.
AEROCOMPACT S®
FS Aero S US 2014.3
www.aerocompact.com
5°/10°/15°
1 kWp /
10 min.
ETL
listed to
UL 2703
PATENT
PENDING
WIND
TUNNEL
TESTED
YE
A R S G A R A N
TY
25
Mercy Hospital Solar Project 25.5kW 6) Racking Data
Aerocompact®
15979 N. 76th ST, Suite A
Scottsdale, AZ 85260
T: 480 432 3900
E: office@aerocompact.com
www.aerocompact.com
>	Mounting tilt: 5° / 10° / 15°
>	 Orientation: south
>	 Avarage additional load of 2.1 lbs per sqf
incl. module
>	Minimum construction size: two modules
>	Edge distances: installation areas of F and G
can be used (please use software tool)
>	 Dimensions for framed modules are
	 (37.4 – 41.3) inch x (64.1 - 78) inch
>	 We require the use of an roof insulation
with a high load capacity.
>	Maximum permitted roof slope 4°
>	Maximum roof height 82 ft
>	 Up to wind load zone 4
>	 Snowload for Aerocompact S® Alpine is 113 psf,
for Aerocompact S® Standard 50 psf
>	Proof of static load capacity of the roof is to be
provided by customer
TECHNICAL DETAILS aerocompact s®
+	 25 years garanty
+	 Best price value available
+	 The fastest installation in the industry
(1 kWp/10 min., 2 men)
+	 Statically optimized system
+	 less material = less shipping costs
+	 Incl. protection pads with aluminum sheet
+	 Optimized wind suction, therefore less ballas-
ting than other systems
+	 Optimum water drainage
+	 Suitable for roof edge zones
+	 ETL certified, conforms to UL 2703
+	 Wind tunnel tested for up to 150 mph
+	 Patent pending
+	 Without roof penetration
+	 Optimum module ventilation
+	 Free ballast calculation incl. roof layout from
our unique online software Aerotool
TECHNICAL
DETAILS
CONTACT
1 kWp /
10 min.
ETL
listed to
UL 2703
PATENT
PENDING
WIND
TUNNEL
TESTED
YE
A R S G A R A N
TY
25
up to 2.4 KN (50 psf) up to 5.4 KN (113 psf)
YOUR
BIG
ADVANTAGE
950 - 1050
10°
250
300 1544
430
Concrete BlocksConcrete Blocks
Abwicklung [mm]:Umkreis [mm]:Allgemeintoleranzen:
Geändert:
Zeichnungsnummer:
System-Komponente:
Werkstoff:Revision:
Produkt:
Massstab:
Freig.
gepr.
gez.
Für diese Zeichnung behalten wir uns alle Rechte vor, auch für den Fall der Patenterteilung oder Gebrauchsmustereintragung. Ohne unsere vorherige, schriftliche Zustimmung darf diese Zeichnung weder verfielfältigt, noch Dritten zugänglich gemacht werden. Diese Zeichnung darf d
zu Schadenersatz und können strafrechtliche Folgen haben. We reserve all rights for this drawing also in case of patent or registration of design. This drawing may neither be copied nor opened to a third party without our written agreement. It may also not be used improperly by the r
Länge [mm]:
64 51 2 3
A
B
21
C
F
E
D
M. Auer
M. Auer
.
Aerocompact GmbH
Bahnhofstraße 9
A-6824 Schlins
37,40 - 41,40
11,8 53,8
8
5°
10
Concrete BlocksConcrete Blocks
Abwicklung [mm]:Umkreis [mm]: Metergewicht [kg/m]:Gewicht [kg]:
A3
E
iy [cm]:
ix [cm]:
Wy [cm3]:
Wx [cm3]:
Jy [cm4]:
Jx [cm4]:
Querschnittsfläche [cm2]:Volumen [cm3]:
Y
Y
X X
oleranzen:
Geändert:
Zeichnungsnummer:
System-Komponente:
Werkstoff:Revision:
Produkt:
Massstab:
Freig.
gepr.
gez.
ung behalten wir uns alle Rechte vor, auch für den Fall der Patenterteilung oder Gebrauchsmustereintragung. Ohne unsere vorherige, schriftliche Zustimmung darf diese Zeichnung weder verfielfältigt, noch Dritten zugänglich gemacht werden. Diese Zeichnung darf durch den Empfänger oder Dritte auch nicht in anderer Weise missbräulich verwendet werden. Zuwiderhandlungen verpflichten
z und können strafrechtliche Folgen haben. We reserve all rights for this drawing also in case of patent or registration of design. This drawing may neither be copied nor opened to a third party without our written agreement. It may also not be used improperly by the recipient or a third party in other ways. Contraventions oblige to compensation and can be prosecuted.
Statische
Werte:
Länge [mm]:
B
A
8764
D
C
51 2 3
21
M. Auer
M. Auer
.
0
Aerocompact GmbH
Bahnhofstraße 9
A-6824 Schlins
20,0811,81
62,80
37,40 - 41,33
15°
12,80
Concrete Blocks Concrete Blocks
Module Size from:
Width 950 - 1050 mm / 37 - 41 inch
Lenght 1630 - 1982 mm / 63 - 78 inch
Abwicklung [mm]:Umkreis [mm]: Metergewicht [kg/m]:Gewicht [kg]:
A3
E
iy [cm]:
ix [cm]:
Wy [cm3]:
Wx [cm3]:
Jy [cm4]:
Jx [cm4]:
Querschnittsfläche [cm2]:Volumen [cm3]:
Y
Y
X X
Allgemeintoleranzen:
Geändert:
Zeichnungsnummer:
System-Komponente:
Werkstoff:Revision:
Produkt:
Massstab:
Freig.
gepr.
gez.
Für diese Zeichnung behalten wir uns alle Rechte vor, auch für den Fall der Patenterteilung oder Gebrauchsmustereintragung. Ohne unsere vorherige, schriftliche Zustimmung darf diese Zeichnung weder verfielfältigt, noch Dritten zugänglich gemacht werden. Diese Zeichnung darf durch den Empfänger oder Dritte auch nicht in anderer Weise missbräulich verwendet werden. Zuwiderhandlungen verpflichten
zu Schadenersatz und können strafrechtliche Folgen haben. We reserve all rights for this drawing also in case of patent or registration of design. This drawing may neither be copied nor opened to a third party without our written agreement. It may also not be used improperly by the recipient or a third party in other ways. Contraventions oblige to compensation and can be prosecuted.
Statische
Werte:
Länge [mm]:
B
A
8764
D
C
51 2 3
A
B
21
C
F
E
D
M. Auer
M. Auer
.
0
S.S.T. Solar System Technik
Bahnhofstraße 9
A-6824 Schlins
15°
10°5°
Mercy Hospital Solar Project 25.5kW
Project report -
Mercy Cross
5/23/2015
Mercy Hospital Solar Project 25.5kW
7) Engineering Design
Page 1 of 15
Location and customer data 2 - 2
Project Location - Google map Google Maps 3 - 3
Roof data 4 - 4
PV-Modules 5 - 5
Racking Parameter 6 - 7
Position 8 - 8
Disposition - Google Maps 9 - 9
Installation Instructions 10 - 10
Roof coordinates CAD 11 - 11
Roof coordinates 12 - 12
Static CAD 13 - 13
Elevation Parameter Additional Info 14 - 14
Additional Information 15 - 15
CONTENTS
Mercy Hospital Solar Project 25.5kW
Page 2 of 15
Project Name Mercy Cross
Project Number:
Comment
Planing Responsible Cris Shirley
System Size [kWp] 25.50
Amount Modules 100
Modul Surface [sf] 1797.573
Name Mercy Cross
Company
Street Address Mercy Way
Postal code 64804
City Joplin
Phone 636-219-0687
Email cris@civicsolar.com
Notes
Country USA
Latitude 37.03793
Longitude -94.5107
Altitude 298
Name Adam Stipanovich
Street Address 1440 E Lark Rd
Postal code 65804
City Springfield
Phone 636-219-0687
Email cris@civicsolar.com
Country USA
MASTER DATA
PROJECT ADDRESS
SHIPPING ADDRESS
Mercy Hospital Solar Project 25.5kW
Page 3 of 15
PROJECT LOCATION - GOOGLE MAP
Mercy Hospital Solar Project 25.5kW
Page 4 of 15
Ridge lengh a [ft] 69.127
Width b [ft] 122.057
Building height h [ft] 25
Slope of roof [°] 3
Roofing TPO membrane
Product Type: Aero S15 7-5
Alignment [°] 231.07
Parapet height [in]: 36
Parapet width [in]: 16
Snow load [PSF]* (si=μi*sk) 10.82
Wind load [PSF] 35
Elevation altitude [in]: 0
Wind speed [mph] 120
Building height h [ft]* 25
Terrain categories Exp C
Type of structure Main Structure
Standard ASCE/SEI 7-10
Risk Category: III/IV
All loads are calculated according to ASCE 7-05 or ASCE 7-10. The wind and snow loads are
evaluated considering the national annex of the US code from Design Criteria by ZIP. According to
the national annex, the user has to check this wind and snow loads with the responsible building
or permitting department.
ROOF [DACH_1]
Custom(Elev.) Alignment [°]*
SNOW LOAD
WIND LOAD
Mercy Hospital Solar Project 25.5kW
Page 5 of 15
Manufacturer: Hanwha Q CELLS GmbH
Name Q.PRO-G3 255
Width [mm]: 1000
Height [mm]: 1670
Gauge [mm]: 35
Framing: Aluminium
Weight (lb) 41.888
Nominal Power [Watt]: 255
Module Type: Polycrystalline
Installation: On Short Side
Framing color Aluminium
Temperatur coefficient [%/°C]: -0.42
Efficiency STC: 0.153
Output voltage IMPP - 500 W /m²: 0
Output voltage VMPP - 500 W/m²: 0
Output voltage IMPP - 100 W /m²: 0
Output voltage VMPP - 100 W/m²: 0
Output current MPP - STC (A): 8.37
Output voltage MPP - STC [V]: 30.77
Short circuit current [A]: 8.9
Open circuit voltage [V]: 37.83
Temperatur coefficient Power [%/K]: 0.04
Temperatur coefficient Voltage [%/K]: -0.33
Max. System voltage EU: 1000
Galvanic seperation required: No
PV-MODULES [DACH_1]
Mercy Hospital Solar Project 25.5kW
Page 6 of 15
Bracket tilt a [°]: 15
Distance between elevation rack rows [in]: 20
Elevation rack depth on the roof b [in]: 43
Maximum height of rack incl. Module [in]: 12.795
Friction Constant µ 0.7
The calculated friction coefficient is based on the TPO product Sika
TrocalRV-s with a friction coefficient of at least 0.83 and Bitumen with
a friction coefficient of at least 0.4 according to the Test results from
the protection pad manufacturer BSW www.berleburger.com.
Document: Coefficient of static friction test, Test results, Date
03.17.2014.
Horizontal separation after [x] modules: 12
Horizontal separation width [in]: 18.898
Vertical separation width [in]: 18.898
Vertical separation after [x] modules: 30
Load backup [PSF]
The examination of the load reserve serves as
an aid in the planning phase. In case of the
realization a building structural engineer has to
examine whether the additional load of the PV
system can be applied to the object.
RACKING PARAMETER [DACH_1]
15
1092.2
Mercy Hospital Solar Project 25.5kW
Page 7 of 15
Horizontal starting point (left bottom in): 10
Vertical starting point (left bottom in in): 10
MODULE LAYOUT PLAN [DACH_1]
Mercy Hospital Solar Project 25.5kW
Page 8 of 15
POSITION
Mercy Hospital Solar Project 25.5kW
Page 9 of 15
DISPOSITION - GOOGLE MAPS
Mercy Hospital Solar Project 25.5kW
Page 10 of 15
INSTALLATION INSTRUCTIONS
Project Name Mercy Cross
Street Address Mercy Way
Postal code 64804
City Joplin
Country USA
Planing Responsible Cris Shirley
Generated date 5/23/2015
Copyright by: Aerocompact
PV-Modul: Q.PRO-G3 255
121'-7.41''
67'-1.57''
120'-11.54''
69'-1.63''
F
FF
F
G
G
G
G
H
End- and middle clamps
PV-Modul
Areas
Mercy Hospital Solar Project 25.5kW
Page 11 of 15
ROOF COORDINATES
69'-1.63''
121'-7.41''
67'-1.57''
120'-11.54''
(0) (1)
(2)(3)
Mercy Hospital Solar Project 25.5kW
Page 12 of 15
Coordinate 0 X: 0 Y: 1.096 Z: 25
Coordinate 1 X: 69.127 Y: 0 Z: 25
Coordinate 2 X: 67.556 Y: 121.608 Z: 25
Coordinate 3 X: 0.427 Y: 122.057 Z: 25
ROOF COORDINATES
Mercy Hospital Solar Project 25.5kW
Page 13 of 15
STATIC INFORMATION: BALLASTING
Project Name Mercy Cross
Street Address Mercy Way
Postal code 64804
City Joplin
Country USA
Planing Responsible Cris Shirley
Generated date 5/23/2015
Copyright by: Aerocompact
PV-Modul: Q.PRO-G3 255
121'-7.41''
67'-1.57''
120'-11.54''
69'-1.63''
F
FF
F
G
G
G
G
H
Area : 0 Area : 1 Area : 2 Area : 3
Area : 4 Area : 5 Area : 6 Area : 7
Area : 8 Area : 9 Area : 10 Area : 11
Area : 12 Area : 13 Area : 14 Area : 15
Area : 16 Area : 17 Area : 18 Area : 19
Area : 20 Area : 21 Area : 22 Area : 23
Area : 24 Area : 25 Area : 26 Area : 27
Area : 28 Area : 29 Area : 30 Area : 31
Area : 32 Area : 33 Area : 34 Area : 35
Area : 36 Area : 37 Area : 38 Area : 39
Area : 40 Area : 41 Area : 42 Area : 43
Area : 44 Area : 45 Area : 46 Area : 47 Area : 48 Area : 49 Area : 50 Area : 51 Area : 52 Area : 53
Area : 54 Area : 55 Area : 56 Area : 57 Area : 58 Area : 59 Area : 60 Area : 61 Area : 62 Area : 63
Area : 64 Area : 65 Area : 66 Area : 67 Area : 68 Area : 69 Area : 70 Area : 71 Area : 72 Area : 73
Area : 74 Area : 75 Area : 76 Area : 77 Area : 78 Area : 79 Area : 80 Area : 81 Area : 82 Area : 83
Area : 84 Area : 85 Area : 86 Area : 87
Area : 88 Area : 89 Area : 90 Area : 91
Area : 92 Area : 93 Area : 94 Area : 95
Area : 96 Area : 97 Area : 98 Area : 99
M:4
3
10
M:4
3
21
M:4
3
22
M:4
3
22
M:4
3
10
13 24 25 25 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13
13 25 25 26 13M:4
3
10
M:4
3
21
M:4
3
22 18 8
M:4
5
M:4
7 17
M:4
3
22
M:4
3
22
M:4
3
10
13 24 25 18 8
M:4
5
M:4
7 17 25 25 13
16 32 32 21 8
M:4
5
M:4
7 21 32 32 16
16 32 32 21 8
M:4
5
M:4
7 21 32 32 16
13 25 25 26 13
13 25 25 26 13
16 32 32 32 16
16 32 32 32 16
End- and middle clamps
PV-Modul
Areas
Load
3 x 15lb
5 x 15lb
7 x 15lb
8 x 15lb
10 x 15lb
13 x 15lb
16 x 15lb
17 x 15lb
18 x 15lb
21 x 15lb
22 x 15lb
24 x 15lb
25 x 15lb
26 x 15lb
32 x 15lb
Mercy Hospital Solar Project 25.5kW
Please Note that this Ballast Layout
has been altered.
Contact Billy Arthur, MO PE for more
information:
314-650-3263
bill@missourisunsolar.com
Page 14 of 15
The surface load of the system (incl. interrow spacing) incl. Module,
mounting system and ballasting is:
14.12 psf
Note: The red circles indicate the brackets where the standard wind sheet is replaced by the high
ballast wind sheet. The high ballast wind sheet is also used in seismic regions as a ballast tray.
Safety against Uplift 1.6
Safety against Shift 1.6
Safety for Weight 0.9
Weight per ballast block [lbs] 15 |
Amount Stones: 2382
Standard ASCE/SEI 7-5
System surface area [sf] 2933.30
Total weight ballasting [lb] 35730.098
Weight Module/Rack [lb] 5675.36
Total System weight [lb] 41405.436
Static calculation is based on Windtunnel Report from I.F.I. Institut für
Industrieaerodynamik GmbH, Report Nr. SSS01-3 and SSS01-5 issued
04.30.2014
The analysis of load bearing capacity and serviceability for the system Aerocompact S is calculated
with the following load and design:
Dead load + snow + wind load: up to 2,4 kN/m² Standard-Version
The structural analysis has been prepared and documented with the statics software Scia Engineer
and Ansys, which are independent from the Solar.Pro.Tool.
Direction definition of the Horizontal Wind-Force: Fx,k und Fy,k :
orizontal components of Wind-Force in the x direction, which
effects the whole Aerocompact System (Characteristic value
without safety factors):
Fx,k=49.84 kN
Horizontal components of Wind-Force in the y direction, which
effects the whole Aerocompact System (Characteristic value
without safety factors):
Fy,k=2.8 kN
RACKING PARAMETER
Mercy Hospital Solar Project 25.5kW
Page 15 of 15
DISCLAIMER/OTHER LIABILITY
1. This current order specifies expressly no review of any information provided by Principal.
Any pertinent review must be ordered expressly and separately in writing.
2. The current report is based on the documents or information and data received by
Principal.
3. Therefore, this report can only be as good as the quality of the information of the Principal
permits.
4. For these reasons, no liability whatsoever and no warranty for errors based on untrue
information of the Principal can be assumed despite any applied due diligence. However,
any liability toward third parties is excluded.
5. Contractor (Aerocompact) shall be liable toward Principal only in cases of gross
negligence (intent or gross negligence) except for personal injuries. This applies equally to
damages to third parties engaged by Contractor.
6. Principal is only entitled to file a claim for damages within six months from the date the
damaged party gained knowledge of the damage but no later than within two years following
the incident on which the claim is based.
7. Principal has the burden of proof, i.e. Principal must show that the damage is caused by
Principal.
8. The structural calculation of the building components refers only to these components.
9. The Supplier is not responsible for the project-related structural soundness of the roof
structure and the professional realization and installation.
10. The technical specifications are an integral part of the product. AEROCOMPACT® shall
not be liable for damages caused by non-compliance with the installation instructions and
particularly with the safety information and from the improper use of the products. The
current Terms and Conditions, Warranty Terms and Conditions and Installation Instructions
will be provided on www.aerocompact.com .
11. If the roof gravel is located directly on top of the water-bearing roof membrane,
Aerocompact® cannot be placed on the gravel layer. In this case the gravel must be removed
in the area of the Aerocompact® bracket.
12. Minimum compressive strength of roof insulation 0.25 Kg/cm2 exclusive Snow Load. An
approval from the roof-membrane manufacturer is required.
13. Photovoltaic flat roof systems are not maintenance free. Maintenance, particular the right
postion of the ballast stones and the building protection pads should be conducted annually.
For exceptional high-wind events, we recommend to do a Maintenance right after the storm
event.
14. Place of jurisdiction, Maricopa County, Arizona
Mercy Hospital Solar Project 25.5kW

More Related Content

Similar to Mercy 25.5kW Planset R1

VIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENT
VIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENTVIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENT
VIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENTVikram Solar
 
iMovR Lander Desk Warranty
iMovR Lander Desk WarrantyiMovR Lander Desk Warranty
iMovR Lander Desk WarrantyiMovR
 
VEMC Solar Solutions: A Step Towards A Greener Future Solutions
VEMC Solar Solutions: A Step Towards A Greener Future SolutionsVEMC Solar Solutions: A Step Towards A Greener Future Solutions
VEMC Solar Solutions: A Step Towards A Greener Future Solutionsjackmethyu
 
Trusted Solar Panel Suppliers & Installation
Trusted Solar Panel Suppliers & InstallationTrusted Solar Panel Suppliers & Installation
Trusted Solar Panel Suppliers & Installationanshparmar
 
Sustainable Solar Energy Solutions for Homes and Businesses
Sustainable Solar Energy Solutions for Homes and BusinessesSustainable Solar Energy Solutions for Homes and Businesses
Sustainable Solar Energy Solutions for Homes and BusinessesVijayEngineeringandM1
 
Kuhn 2200 tandem disc harrow
Kuhn 2200 tandem disc harrowKuhn 2200 tandem disc harrow
Kuhn 2200 tandem disc harrowPartCatalogs Net
 
2005 kawasaki kvf750 a1 service repair manual
2005 kawasaki kvf750 a1 service repair manual2005 kawasaki kvf750 a1 service repair manual
2005 kawasaki kvf750 a1 service repair manualfjskkmemem
 
2005 kawasaki kvf750 b1 service repair manual
2005 kawasaki kvf750 b1 service repair manual2005 kawasaki kvf750 b1 service repair manual
2005 kawasaki kvf750 b1 service repair manualfhjsekkemm
 
TypeApproval_aw-scl-05LA
TypeApproval_aw-scl-05LATypeApproval_aw-scl-05LA
TypeApproval_aw-scl-05LAKen/Youqiang Qu
 
Kuhn chisel chs 4000 chiselplow 4000
Kuhn chisel chs 4000 chiselplow 4000Kuhn chisel chs 4000 chiselplow 4000
Kuhn chisel chs 4000 chiselplow 4000PartCatalogs Net
 
Kuhn 5630 hr flex wing field cultivator
Kuhn 5630 hr flex wing field cultivatorKuhn 5630 hr flex wing field cultivator
Kuhn 5630 hr flex wing field cultivatorPartCatalogs Net
 
Kuhn 5800 offset disc harrow
Kuhn 5800 offset disc harrowKuhn 5800 offset disc harrow
Kuhn 5800 offset disc harrowPartCatalogs Net
 
388865344-990dsl-Manu-copper-loop-tester.pdf
388865344-990dsl-Manu-copper-loop-tester.pdf388865344-990dsl-Manu-copper-loop-tester.pdf
388865344-990dsl-Manu-copper-loop-tester.pdfMohamedshabana38
 
Kuhn 5200 nt series grain drill
Kuhn 5200 nt series grain drillKuhn 5200 nt series grain drill
Kuhn 5200 nt series grain drillPartCatalogs Net
 

Similar to Mercy 25.5kW Planset R1 (20)

VIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENT
VIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENTVIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENT
VIKRAM SOLAR'S PRODUCTS & PERFORMANCE COMMITMENT
 
Warranty Policy
Warranty PolicyWarranty Policy
Warranty Policy
 
Optimus warranty
Optimus warrantyOptimus warranty
Optimus warranty
 
iMovR Lander Desk Warranty
iMovR Lander Desk WarrantyiMovR Lander Desk Warranty
iMovR Lander Desk Warranty
 
VEMC Solar Solutions: A Step Towards A Greener Future Solutions
VEMC Solar Solutions: A Step Towards A Greener Future SolutionsVEMC Solar Solutions: A Step Towards A Greener Future Solutions
VEMC Solar Solutions: A Step Towards A Greener Future Solutions
 
Trusted Solar Panel Suppliers & Installation
Trusted Solar Panel Suppliers & InstallationTrusted Solar Panel Suppliers & Installation
Trusted Solar Panel Suppliers & Installation
 
Sustainable Solar Energy Solutions for Homes and Businesses
Sustainable Solar Energy Solutions for Homes and BusinessesSustainable Solar Energy Solutions for Homes and Businesses
Sustainable Solar Energy Solutions for Homes and Businesses
 
Kuhn 2200 tandem disc harrow
Kuhn 2200 tandem disc harrowKuhn 2200 tandem disc harrow
Kuhn 2200 tandem disc harrow
 
2005 kawasaki kvf750 a1 service repair manual
2005 kawasaki kvf750 a1 service repair manual2005 kawasaki kvf750 a1 service repair manual
2005 kawasaki kvf750 a1 service repair manual
 
2005 kawasaki kvf750 b1 service repair manual
2005 kawasaki kvf750 b1 service repair manual2005 kawasaki kvf750 b1 service repair manual
2005 kawasaki kvf750 b1 service repair manual
 
TypeApproval_aw-scl-05LA
TypeApproval_aw-scl-05LATypeApproval_aw-scl-05LA
TypeApproval_aw-scl-05LA
 
Kuhn chisel chs 4000 chiselplow 4000
Kuhn chisel chs 4000 chiselplow 4000Kuhn chisel chs 4000 chiselplow 4000
Kuhn chisel chs 4000 chiselplow 4000
 
Kuhn 5630 hr flex wing field cultivator
Kuhn 5630 hr flex wing field cultivatorKuhn 5630 hr flex wing field cultivator
Kuhn 5630 hr flex wing field cultivator
 
Kuhn 5800 offset disc harrow
Kuhn 5800 offset disc harrowKuhn 5800 offset disc harrow
Kuhn 5800 offset disc harrow
 
Kuhn chs 4000 19
Kuhn chs 4000 19Kuhn chs 4000 19
Kuhn chs 4000 19
 
Kuhn drd 3000 7R
Kuhn drd 3000 7RKuhn drd 3000 7R
Kuhn drd 3000 7R
 
Kuhn drd 3000 5
Kuhn drd 3000 5Kuhn drd 3000 5
Kuhn drd 3000 5
 
Hague watermax
Hague watermaxHague watermax
Hague watermax
 
388865344-990dsl-Manu-copper-loop-tester.pdf
388865344-990dsl-Manu-copper-loop-tester.pdf388865344-990dsl-Manu-copper-loop-tester.pdf
388865344-990dsl-Manu-copper-loop-tester.pdf
 
Kuhn 5200 nt series grain drill
Kuhn 5200 nt series grain drillKuhn 5200 nt series grain drill
Kuhn 5200 nt series grain drill
 

Mercy 25.5kW Planset R1

  • 1.
  • 2.
  • 3.
  • 4.
  • 5. Mercy Hospital Solar Project 25.5kW 1) Panel Data
  • 6. Mercy Hospital Solar Project 25.5kW
  • 7. LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM [HANWHA Q . C E L L S GMBH]     Dear Customer, You have made an excellent choice in purchasing quality modules from [Hanwha Q.CELLS GmbH] (“Q CELLS”). The photovoltaic modules you have purchased have been manufactured with great care and have undergone a final functional test. We also provide the following limited warranty (“Warranty”): SCOPE This Warranty applies exclusively to Q CELLS photovoltaic modules of the following types (the “Modules”): • Q.PEAK G2 • Q.PEAK G3 • Q.PEAK BLK G2 • Q.PEAK BLK G3 • Q.PRO G2 • Q.PRO G3 • Q.PRO L All Modules must be sold and installed within the United States and bear our manufacturer‘s label to be eligible for this Warranty. Warrantor is Hanwha Q.CELLS GmbH, OT Thalheim, Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany. The applicable Warranty period begins on the date of the initial purchase of the Modules by the original end customer as set forth in the applicable invoice (the “Purchase Date”). 12-YEAR PRODUCT WARRANTY Q CELLS warrants to you that Modules which are installed in accordance with the applicable installation and operation manual and other product documentation provided to customers by Q CELLS for the Modules (collectively, “Product Instructions”) will not show any defects in materials or workmanship for a period of twelve years after the applicable Purchase Date. In the event that a Module has any such defect covered by this warranty (case of warranty), Q CELLS, at its choice, will either repair the defect or supply a replacement Module. If Q CELLS is unable to repair the defect or supply a replacement Module, Q CELLS will have the right to refund you the prorated value of the purchase price paid by you to Q CELLS or Q CELLS’ authorized reseller for the affected Modules (“Purchase Price”), provided that you first return to Q CELLS the affected Module. The foregoing constitutes your sole and exclusive remedy for a breach of the warranty set forth in this paragraph (the “Product Warranty”). 25-YEAR LINEAR PERFORMANCE WARRANTY In addition, Q CELLS provides you the following performance warranty (“Performance Warranty”) for Modules which are installed in accordance with the applicable Product Instructions: In the first year after the Purchase Date the Modules will produce a minimum power output of at least 97 % of that specified in the Module data sheet. From a period beginning on the first anniversary of the Purchase Date and ending on the twenty-fifth anniversary of the Purchase Date, the Modules will have a yearly maximum decrease of power output (degradation) of not more than 0.6 % of the power output specified in the Module data sheet within the framework of the power tolerance, i.e. the Module will have a minimum power output of at least 83 % of the power output specified in the Module data sheet at the end of the twenty-five year period. All power output measurements will be performed under the STC Standard Test Conditions used by Q CELLS on the Purchase Date. The STC Standard Test Conditions are customary standardized basic conditions for the measurement of the power of solar modules. The currently valid STC Standard Test Conditions are defined in the IEC standards EN 61215 and 60904-3. In the event of a breach of this Performance Warranty, Q CELLS will, at its choice, repair the defect, replace the affected Module, supply additional modules sufficient to make up for the power output reduction, refund you the full Purchase Price of the affected Module provided that you first return to Q CELLS the affected Module, or refund you a percentage of the Purchase Price of the affected Module equal to the percentage reduction in minimum power output compared to the minimum power output warranted under this Performance Warranty. The foregoing constitutes your sole and exclusive remedy for a breach of this Performance Warranty. EXCLUSIONS FROM THE PRODUCT AND PERFORMANCE WARRANTY Irrespective of contributory root causes, this Warranty does not cover the following cases: • Handling, storage, installation, configuration, testing, or use not in accordance with the Product Instructions (e.g., static, installation of mutually incompatible modules, inadequate system design, and incompatible inverter); • Repair, servicing or maintenance work not in accordance with the Product Instructions or failure to perform maintenance as required by the Product Instructions. • Usage in an environment outside the parameters specified in the Product Instructions, including without limitation high snow load outside such parameters; • Usage for purposes or in circumstances not conforming to the product specifications (as set out in the module data sheet applicable to the modules in any given case) and not complying with the installation and operating instructions; • Damage caused by environmental sources, such as but not limited to pollution of any kind as well as fire, explosion, smoke or charring; • Damage caused by acts of nature or God, including without limitation lightning, hail, frost, snow, or storms; • Damage caused by abuse, negligence, neglect, or accident, including without limitation acts of violence and vandalism • Damages to the photovoltaic system in which the Modules are installed, or damages caused by factors such as voltage fluctuations, power peaks, excess voltage, power failure etc.; • Scratches, marks, mechanical wear, rust, mold, degradation, dis-coloration and other changes which occur after the delivery of the Modules but which do not result in any adverse effect on the mechanical stability of the Module or a reduction of performance which exceeds the levels set out in the Performance Warranty; and • Issues not reproducible by Q CELLS. The following cases are also excluded from the Warranty: • The Q CELLS Modules are modified or altered or used in processes involving other products without obtaining prior written consent from Q CELLS. • The serial number or product label has been removed, changed, deleted or made unrecognizable or if it is no longer clearly distinguishable for other reasons beyond Q CELLS’ control and therefore it is not possible to conclusively identify the Modules. Use on mobile carriers such as motor vehicles or ships. As part of the warranty there is no claim to compensation for the Mercy Hospital Solar Project 25.5kW 2) Panel Warranty
  • 8. LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM [HANWHA Q . C E L L S GMBH]     reimbursement of costs for dismantling, installation or replacement, loss of yield or other indirect damages. CLAIMS UNDER WARRANTY/NOTIFICATION OF DEFECTS You must check the Modules for visible defects upon delivery. If you discover any defects, you must report these immediately to Q CELLS. You must report any Warranty claim to Q CELLS during the applicable Warranty period and no later than thirty (30) days after discovering the breach of Warranty. Please contact us first in writing or electronically. Contact information, the required data and the procedure of the complaint process are described in document Q CELLS’ RMA process (Return Merchandise Authorization). You must follow the RMA process to be eligible for Warranty service. If you have any questions please contact your seller or Q CELLS at the following e-mail address: service@q-cells.com. We ask for our customers’ understanding that Q CELLS cannot accept any unauthorized return shipments of Modules and will not take delivery of such items. PERFORMANCE OF THE WARRANTY SERVICES In all cases, Q CELLS shall have the choice in accordance with this Warranty as to how Warranty claims are settled. Q CELLS may use the services of a third party service partner for this purpose. • Q CELLS shall pay the costs of a technical inspection of the affected Module in case of a Warranty claim. If there is no breach of Warranty as reasonably determined by Q CELLS, you will pay these costs • Q CELLS shall only accept liability under the performance warranty if the performance parameters measured by Q CELLS in the STCs (Standard Test Conditions) are not achieved. • The returned Modules shall remain your property unless Q CELLS chooses to replace such Modules, in which case ownership of the replaced Modules passes to Q CELLS. • Any repaired or replaced Modules shall be covered by the Warranty for the remaining portion of the original Warranty period as applicable. • If Q CELLS supplies replacement or additional modules under this Warranty and the original Module type is no longer available, Q CELLS will have the right to provide replacement or additional modules of a similar or equivalent type from the product range available at the time of the claim as long as they are suitable for the intended purpose. • In the event of glass breakage, Q CELLS reserves the right to perform a static calculation to verify the substructure was designed in accordance with the Product Instructions. • Q CELLS will have no liability in connection with this Warranty for any costs or expenses of dismantling or installing Modules or replacement modules. DISCLAIMER EXCEPT AS EXPRESSLY SET FORTH IN THE PRODUCT WARRANTY AND THE PERFORMANCE WARRANTY, Q CELLS HEREBY DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS, IMPLIED, OR STATUTORY, REGARDING THE MODULES, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT OF THIRD-PARTY RIGHTS, AND SYSTEM INTEGRATION. LIMITATION OF LIABILITY Q CELLS WILL NOT BE LIABLE FOR ANY CONSEQUENTIAL, EXEMPLARY, SPECIAL, INDIRECT, OR INCIDENTAL DAMAGES, INCLUDING ANY DAMAGES FOR LOST PROFITS OR LOSS OF YIELD, ARISING FROM OR RELATING TO THIS WARRANTY OR THE MODULES, EVEN IF Q CELLS KNEW OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES. Q CELLS’ TOTAL CUMULATIVE LIABILITY ARISING FROM OR RELATED TO THIS WARRANTY AND THE MODULES, WHETHER IN CONTRACT OR TORT OR OTHERWISE, WILL NOT EXCEED THE PRODUCT PRICE FOR THE MODULE(S) AT ISSUE. THE FOREGOING LIMITATIONS OF LIABILITY ARE INDEPENDENT OF EXCLUSIVE REMEDIES FOR BREACH OF THIS WARRANTY. Q CELLS DISCLAIMS ALL LIABILITY OF ANY KIND OF Q CELLS’ SUPPLIERS UNDER THIS AGREEMENT. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. THE DISCLAIMERS, EXCLUSIONS, AND LIMITATIONS OF LIABILITY UNDER THIS WARRANTY WILL NOT APPLY TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ASSIGNMENT OF WARRANTY FOR PV MODULES This Warranty for PV Modules in its entirety, extends only to the original purchaser, and is transferrable in its entirety to any other person to whom title to the PV Modules has been transferred provided that a) a prior written notice of such transfer has been received by Q CELLS, and b) the PV Modules remain installed in their original installation location. GOVERNING LAW These Warranty terms and conditions shall be exclusively governed by the laws of the State of California, without giving effect to any conflict of laws principles that would require the application of the laws of another State laws principles that would require the application of the laws of another State. Mercy Hospital Solar Project 25.5kW
  • 9. STP12000Tl-US-10/STP15000Tl-US-10/STP20000Tl-US-10/STP24000TL-US-10 Design flexibility • 1000 V DC or 600 V DC • Two independent DC inputs • 15° to 90° mounting angle range • Detachable DC Connection Unit System efficiency • 98% CEC, 98.5% Peak • 1000 V DC increases system efficiency • OptiTrac advanced MPPT • OptiTrac Global Peak MPPT Enhanced safety • Integrated DC AFCI • Floating system with all-pole sensitive ground fault protection • Reverse polarity indicator Future-proof • Cluster Controller, WebConnect/ Speedwire • Bi-directional Ethernet communications • Complete grid management feature set • Ability to satisfy future utility requirements Sunny Tripower 12000TL-US / 15000TL-US / 20000TL-US / 24000TL-US The ultimate solution for decentralized PV plants SMA’s new Sunny Tripower TL-US is raising the level of performance for decentralized commercial PV plants. This three-phase transformerless inverter is UL listed for up to 1000 V DC maximum system voltage and has peak efficiency above 98 percent, while OptiTrac Global Peak minimizes the effects of shade for maximum energy production. The Sunny Tripower delivers a future-proof solution with full grid management, and communications and monitoring features. The Sunny Tripower is also equipped with all-pole ground fault protection and integrated AFCI for a safe, reliable solution. It offers unmatched flexibility with a wide input voltage range and two independent MPP trackers. Suitable for both 600 V DC and 1,000 V DC applica- tions, the Sunny Tripower allows for flexible design and a lower levelized cost of energy. SUNNY TRIPOWER 12000Tl-US / 15000Tl-US / 20000Tl-US / 24000TL-US Mercy Hospital Solar Project 25.5kW 3) Inverter Data
  • 10. Enhanced power production Leading efficiency and SMA’s proprietary OptiTrac Global Peak MPP tracking means owners benefit from superior power production and improved economics. When operated at 1,000 V DC, balance of system costs can also be significantly reduced. The Sunny Tripower TL-US also features advanced diagnostics, including a reverse polarity indicator via the Connection Unit 1000-US. Future proof The Sunny Tripower TL-US includes a number of technologies designed to meet tomorrow’s requirements. Full grid management functionality is available, as are cutting edge communication options like SMA’s Cluster Controller and Speedwire. SMA Service can also simplify long-term planning with comprehensive packages covering inverters through plant-wide operations and maintenance (O&M). And, as a decentralized technology, inverter- level O&M is reduced from the beginning compared to centralized architecture. Optimized cost The Sunny Tripower TL-US allows integrators to optimally use real estate, shorten design and installation time, and produce more power. Inverter-level O&M is reduced through string technology and long-term support is made simple through SMA’s service organization, making the Sunny Tripower TL-US the ultimate solution for decentralized PV. The Sunny Tripower TL-US is engineered to optimize design, production, and reliability— reducing a project’s levelized cost of energy and improving its financial returns. Unmatched flexibility Available in four power classes, the Sunny Tripower TL-US features a wide operating window, two MPP trackers, and 600 V DC or 1,000 V DC operation, making it ideal for any decentralized project. System engineering is made simple and repeatable, resulting in a shortened design cycle. Easy to transport and install, the Sunny Tripower can be mounted in a variety of ways from vertical to nearly horizontal. Concrete pads usually required by central inverters are unnecessary, preserving site real estate. THE TOTAL PACKAGE Mercy Hospital Solar Project 25.5kW
  • 11. Technical data Sunny Tripower 12000TL-US Sunny Tripower 15000TL-US Sunny Tripower 20000TL-US Sunny Tripower 24000TL-US Input (DC) Max. recommended PV power (@ module STC) 15000 W 18750 W 25000 W 30000 W Max. DC voltage* 1000 V 1000 V 1000 V 1000 V Rated MPPT voltage range 300 V…800 V 300 V…800 V 380 V…800 V 450 V…800 V MPPT operating voltage range 150 V…1000 V 150 V…1000 V 150 V…1000 V 150 V…1000 V Min. DC voltage / start voltage 150 V / 188 V 150 V / 188 V 150 V / 188 V 150 V / 188 V Number of MPP tracker inputs 2 2 2 2 Max. input current / per MPP tracker input 66 A / 33 A 66 A / 33 A 66 A / 33 A 66 A / 33 A Output (AC) AC nominal power 12000 W 15000 W 20000 W 24000 W Max. AC apparent power 12000 VA 15000 VA 20000 VA 24000 VA Output phases / line connections 3 / 3-N-PE Nominal AC voltage 480 / 277 V WYE AC voltage range 244 V…305 V Rated AC grid frequency 60 Hz AC grid frequency / range 50 Hz, 60 Hz / 44 Hz…65 Hz Max. output current 14.4 A 18 A 24 A 29 A Power factor at rated power / adjustable displacement 1 / 0.8 leading…0.8 lagging Harmonics < 3 % Efficiency Max. efficiency 98.2 % 98.2 % 98.5 % 98.5 % CEC efficiency 97.5% 97.5% 97.5% 98.0% Protection devices DC reverse polarity protection ● ● ● ● Ground fault monitoring / Grid monitoring ● ● ● ● All-pole sensitive residual current monitoring unit ● ● ● ● DC AFCI compliant to UL 1699B ● ● ● ● AC short circuit protection ● ● ● ● Protection class / overvoltage category I / IV I / IV I / IV I / IV General data Dimensions (W / H / D) in mm (in) 665 / 690 / 265 (26.1 / 27.1 / 10.4) Packing dimensions (W / H / D) in mm (in) 780 / 790 / 380 (30.7 / 31.1 / 15.0) Weight 55 kg (121 lbs) Packing weight 61 kg (134.5 lbs) Operating temperature range -25°C...+60°C Noise emission (typical) 51 dB(A) Internal consumption at night 1 W Topology Transformerless Cooling concept OptiCool Electronics protection rating NEMA 3R Features Display / LED indicators (Status / Fault / Communication) ̶ / ● ̶ / ● ̶ / ● ̶ / ● Interfaces: Speedwire / RS485 ●/○ ●/○ ●/○ ●/○ Mounting Angle Range 15°…90° 15°…90° 15°…90° 15°…90° Warranty: 10 / 15 / 20 years ●/○/○ ●/○/○ ●/○/○ ●/○/○ Certifications and approvals (pending) UL1741,UL1998,UL1699B,IEEE1547,FCCPart15(ClassA&B),CAN/CSAC22.2107.1-1 NOTE: US inverters ship with gray lids *Suitable for 600 V DC max. systems Type designation STP 12000TL-US-10 STP 15000TL-US-10 STP 20000TL-US-10 STP 24000TL-US-10 Accessories ● Standard features  ○ Optional features  — Not available Data at nominal conditions RS485 interface DM-485CB-US-10 SMA Cluster Controller CLCON-10 Mercy Hospital Solar Project 25.5kW
  • 12. Mercy Hospital Solar Project 25.5kW 4) Inverter Warranty
  • 13. Mercy Hospital Solar Project 25.5kW
  • 14. Mercy Hospital Solar Project 25.5kW
  • 15. Product Data Sheet H362NRB Safety Switch , Fusible, 600V, 3-Pole List Price $1,134.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Disconnect Type Fusible Depth 6.38 Inches Enclosure Rating NEMA 3R Maximum Voltage Rating 600V Height 17.50 Inches Short Circuit Current Rating 10kA (Class H or K) - 200kA (Class R,J or L) Enclosure Type Rainproof and Sleet/Ice proof (Indoor/Outdoor) Width 9.00 Inches Action Single Throw Mounting Type Surface Ampere Rating 60A Enclosure Material Galvannealed Steel Number of Poles 3-Pole Approvals UL Listed Factory Installed Neutral Yes Terminal Type Lugs Wire Size #12 to #2 AWG(Al) or #14 to #2 AWG(Cu) Electrical Interlock None Type of Duty Heavy Duty Technical Characteristics Category 00009 - Safety Switch, Heavy Duty, 2 & 3 Pole, 30-200 Amp, Outdoor Discount Schedule DE1 GTIN 00785901122494 Package Quantity 1 Weight 15.35 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y Country of Origin US Shipping and Ordering As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 05/06/2010 14:48:24 © 2010 Schneider Electric. All rights reserved. 1 Mercy Hospital Solar Project 25.5kW 5) Disconnect Data
  • 16. … the unbeatable aerodynamic flat-roof solution Our aerocompact s® (south oriented), is the aerodynamic solution for mounting framed modules on flat roofs. This system offers the best value for your money and has excellent installation features. With aerocompact s® an assembly time of 10 minutes per kWp can be reached. The system is wind-tunnel tested, conforms to UL 2703 certification and is delivered pre-assembled with protection mats incl. Aluminum coating to prevent diffusion of the plastic softener. You will also re- ceive a free ballast calculation incl. roof layout and a project specific static report, from our unique online software „Aerotool“. aerocompact® „the unbeatable aerodynamic flat-roof solution“. AEROCOMPACT S® FS Aero S US 2014.3 www.aerocompact.com 5°/10°/15° 1 kWp / 10 min. ETL listed to UL 2703 PATENT PENDING WIND TUNNEL TESTED YE A R S G A R A N TY 25 Mercy Hospital Solar Project 25.5kW 6) Racking Data
  • 17. Aerocompact® 15979 N. 76th ST, Suite A Scottsdale, AZ 85260 T: 480 432 3900 E: office@aerocompact.com www.aerocompact.com > Mounting tilt: 5° / 10° / 15° > Orientation: south > Avarage additional load of 2.1 lbs per sqf incl. module > Minimum construction size: two modules > Edge distances: installation areas of F and G can be used (please use software tool) > Dimensions for framed modules are (37.4 – 41.3) inch x (64.1 - 78) inch > We require the use of an roof insulation with a high load capacity. > Maximum permitted roof slope 4° > Maximum roof height 82 ft > Up to wind load zone 4 > Snowload for Aerocompact S® Alpine is 113 psf, for Aerocompact S® Standard 50 psf > Proof of static load capacity of the roof is to be provided by customer TECHNICAL DETAILS aerocompact s® + 25 years garanty + Best price value available + The fastest installation in the industry (1 kWp/10 min., 2 men) + Statically optimized system + less material = less shipping costs + Incl. protection pads with aluminum sheet + Optimized wind suction, therefore less ballas- ting than other systems + Optimum water drainage + Suitable for roof edge zones + ETL certified, conforms to UL 2703 + Wind tunnel tested for up to 150 mph + Patent pending + Without roof penetration + Optimum module ventilation + Free ballast calculation incl. roof layout from our unique online software Aerotool TECHNICAL DETAILS CONTACT 1 kWp / 10 min. ETL listed to UL 2703 PATENT PENDING WIND TUNNEL TESTED YE A R S G A R A N TY 25 up to 2.4 KN (50 psf) up to 5.4 KN (113 psf) YOUR BIG ADVANTAGE 950 - 1050 10° 250 300 1544 430 Concrete BlocksConcrete Blocks Abwicklung [mm]:Umkreis [mm]:Allgemeintoleranzen: Geändert: Zeichnungsnummer: System-Komponente: Werkstoff:Revision: Produkt: Massstab: Freig. gepr. gez. Für diese Zeichnung behalten wir uns alle Rechte vor, auch für den Fall der Patenterteilung oder Gebrauchsmustereintragung. Ohne unsere vorherige, schriftliche Zustimmung darf diese Zeichnung weder verfielfältigt, noch Dritten zugänglich gemacht werden. Diese Zeichnung darf d zu Schadenersatz und können strafrechtliche Folgen haben. We reserve all rights for this drawing also in case of patent or registration of design. This drawing may neither be copied nor opened to a third party without our written agreement. It may also not be used improperly by the r Länge [mm]: 64 51 2 3 A B 21 C F E D M. Auer M. Auer . Aerocompact GmbH Bahnhofstraße 9 A-6824 Schlins 37,40 - 41,40 11,8 53,8 8 5° 10 Concrete BlocksConcrete Blocks Abwicklung [mm]:Umkreis [mm]: Metergewicht [kg/m]:Gewicht [kg]: A3 E iy [cm]: ix [cm]: Wy [cm3]: Wx [cm3]: Jy [cm4]: Jx [cm4]: Querschnittsfläche [cm2]:Volumen [cm3]: Y Y X X oleranzen: Geändert: Zeichnungsnummer: System-Komponente: Werkstoff:Revision: Produkt: Massstab: Freig. gepr. gez. ung behalten wir uns alle Rechte vor, auch für den Fall der Patenterteilung oder Gebrauchsmustereintragung. Ohne unsere vorherige, schriftliche Zustimmung darf diese Zeichnung weder verfielfältigt, noch Dritten zugänglich gemacht werden. Diese Zeichnung darf durch den Empfänger oder Dritte auch nicht in anderer Weise missbräulich verwendet werden. Zuwiderhandlungen verpflichten z und können strafrechtliche Folgen haben. We reserve all rights for this drawing also in case of patent or registration of design. This drawing may neither be copied nor opened to a third party without our written agreement. It may also not be used improperly by the recipient or a third party in other ways. Contraventions oblige to compensation and can be prosecuted. Statische Werte: Länge [mm]: B A 8764 D C 51 2 3 21 M. Auer M. Auer . 0 Aerocompact GmbH Bahnhofstraße 9 A-6824 Schlins 20,0811,81 62,80 37,40 - 41,33 15° 12,80 Concrete Blocks Concrete Blocks Module Size from: Width 950 - 1050 mm / 37 - 41 inch Lenght 1630 - 1982 mm / 63 - 78 inch Abwicklung [mm]:Umkreis [mm]: Metergewicht [kg/m]:Gewicht [kg]: A3 E iy [cm]: ix [cm]: Wy [cm3]: Wx [cm3]: Jy [cm4]: Jx [cm4]: Querschnittsfläche [cm2]:Volumen [cm3]: Y Y X X Allgemeintoleranzen: Geändert: Zeichnungsnummer: System-Komponente: Werkstoff:Revision: Produkt: Massstab: Freig. gepr. gez. Für diese Zeichnung behalten wir uns alle Rechte vor, auch für den Fall der Patenterteilung oder Gebrauchsmustereintragung. Ohne unsere vorherige, schriftliche Zustimmung darf diese Zeichnung weder verfielfältigt, noch Dritten zugänglich gemacht werden. Diese Zeichnung darf durch den Empfänger oder Dritte auch nicht in anderer Weise missbräulich verwendet werden. Zuwiderhandlungen verpflichten zu Schadenersatz und können strafrechtliche Folgen haben. We reserve all rights for this drawing also in case of patent or registration of design. This drawing may neither be copied nor opened to a third party without our written agreement. It may also not be used improperly by the recipient or a third party in other ways. Contraventions oblige to compensation and can be prosecuted. Statische Werte: Länge [mm]: B A 8764 D C 51 2 3 A B 21 C F E D M. Auer M. Auer . 0 S.S.T. Solar System Technik Bahnhofstraße 9 A-6824 Schlins 15° 10°5° Mercy Hospital Solar Project 25.5kW
  • 18. Project report - Mercy Cross 5/23/2015 Mercy Hospital Solar Project 25.5kW 7) Engineering Design
  • 19. Page 1 of 15 Location and customer data 2 - 2 Project Location - Google map Google Maps 3 - 3 Roof data 4 - 4 PV-Modules 5 - 5 Racking Parameter 6 - 7 Position 8 - 8 Disposition - Google Maps 9 - 9 Installation Instructions 10 - 10 Roof coordinates CAD 11 - 11 Roof coordinates 12 - 12 Static CAD 13 - 13 Elevation Parameter Additional Info 14 - 14 Additional Information 15 - 15 CONTENTS Mercy Hospital Solar Project 25.5kW
  • 20. Page 2 of 15 Project Name Mercy Cross Project Number: Comment Planing Responsible Cris Shirley System Size [kWp] 25.50 Amount Modules 100 Modul Surface [sf] 1797.573 Name Mercy Cross Company Street Address Mercy Way Postal code 64804 City Joplin Phone 636-219-0687 Email cris@civicsolar.com Notes Country USA Latitude 37.03793 Longitude -94.5107 Altitude 298 Name Adam Stipanovich Street Address 1440 E Lark Rd Postal code 65804 City Springfield Phone 636-219-0687 Email cris@civicsolar.com Country USA MASTER DATA PROJECT ADDRESS SHIPPING ADDRESS Mercy Hospital Solar Project 25.5kW
  • 21. Page 3 of 15 PROJECT LOCATION - GOOGLE MAP Mercy Hospital Solar Project 25.5kW
  • 22. Page 4 of 15 Ridge lengh a [ft] 69.127 Width b [ft] 122.057 Building height h [ft] 25 Slope of roof [°] 3 Roofing TPO membrane Product Type: Aero S15 7-5 Alignment [°] 231.07 Parapet height [in]: 36 Parapet width [in]: 16 Snow load [PSF]* (si=μi*sk) 10.82 Wind load [PSF] 35 Elevation altitude [in]: 0 Wind speed [mph] 120 Building height h [ft]* 25 Terrain categories Exp C Type of structure Main Structure Standard ASCE/SEI 7-10 Risk Category: III/IV All loads are calculated according to ASCE 7-05 or ASCE 7-10. The wind and snow loads are evaluated considering the national annex of the US code from Design Criteria by ZIP. According to the national annex, the user has to check this wind and snow loads with the responsible building or permitting department. ROOF [DACH_1] Custom(Elev.) Alignment [°]* SNOW LOAD WIND LOAD Mercy Hospital Solar Project 25.5kW
  • 23. Page 5 of 15 Manufacturer: Hanwha Q CELLS GmbH Name Q.PRO-G3 255 Width [mm]: 1000 Height [mm]: 1670 Gauge [mm]: 35 Framing: Aluminium Weight (lb) 41.888 Nominal Power [Watt]: 255 Module Type: Polycrystalline Installation: On Short Side Framing color Aluminium Temperatur coefficient [%/°C]: -0.42 Efficiency STC: 0.153 Output voltage IMPP - 500 W /m²: 0 Output voltage VMPP - 500 W/m²: 0 Output voltage IMPP - 100 W /m²: 0 Output voltage VMPP - 100 W/m²: 0 Output current MPP - STC (A): 8.37 Output voltage MPP - STC [V]: 30.77 Short circuit current [A]: 8.9 Open circuit voltage [V]: 37.83 Temperatur coefficient Power [%/K]: 0.04 Temperatur coefficient Voltage [%/K]: -0.33 Max. System voltage EU: 1000 Galvanic seperation required: No PV-MODULES [DACH_1] Mercy Hospital Solar Project 25.5kW
  • 24. Page 6 of 15 Bracket tilt a [°]: 15 Distance between elevation rack rows [in]: 20 Elevation rack depth on the roof b [in]: 43 Maximum height of rack incl. Module [in]: 12.795 Friction Constant µ 0.7 The calculated friction coefficient is based on the TPO product Sika TrocalRV-s with a friction coefficient of at least 0.83 and Bitumen with a friction coefficient of at least 0.4 according to the Test results from the protection pad manufacturer BSW www.berleburger.com. Document: Coefficient of static friction test, Test results, Date 03.17.2014. Horizontal separation after [x] modules: 12 Horizontal separation width [in]: 18.898 Vertical separation width [in]: 18.898 Vertical separation after [x] modules: 30 Load backup [PSF] The examination of the load reserve serves as an aid in the planning phase. In case of the realization a building structural engineer has to examine whether the additional load of the PV system can be applied to the object. RACKING PARAMETER [DACH_1] 15 1092.2 Mercy Hospital Solar Project 25.5kW
  • 25. Page 7 of 15 Horizontal starting point (left bottom in): 10 Vertical starting point (left bottom in in): 10 MODULE LAYOUT PLAN [DACH_1] Mercy Hospital Solar Project 25.5kW
  • 26. Page 8 of 15 POSITION Mercy Hospital Solar Project 25.5kW
  • 27. Page 9 of 15 DISPOSITION - GOOGLE MAPS Mercy Hospital Solar Project 25.5kW
  • 28. Page 10 of 15 INSTALLATION INSTRUCTIONS Project Name Mercy Cross Street Address Mercy Way Postal code 64804 City Joplin Country USA Planing Responsible Cris Shirley Generated date 5/23/2015 Copyright by: Aerocompact PV-Modul: Q.PRO-G3 255 121'-7.41'' 67'-1.57'' 120'-11.54'' 69'-1.63'' F FF F G G G G H End- and middle clamps PV-Modul Areas Mercy Hospital Solar Project 25.5kW
  • 29. Page 11 of 15 ROOF COORDINATES 69'-1.63'' 121'-7.41'' 67'-1.57'' 120'-11.54'' (0) (1) (2)(3) Mercy Hospital Solar Project 25.5kW
  • 30. Page 12 of 15 Coordinate 0 X: 0 Y: 1.096 Z: 25 Coordinate 1 X: 69.127 Y: 0 Z: 25 Coordinate 2 X: 67.556 Y: 121.608 Z: 25 Coordinate 3 X: 0.427 Y: 122.057 Z: 25 ROOF COORDINATES Mercy Hospital Solar Project 25.5kW
  • 31. Page 13 of 15 STATIC INFORMATION: BALLASTING Project Name Mercy Cross Street Address Mercy Way Postal code 64804 City Joplin Country USA Planing Responsible Cris Shirley Generated date 5/23/2015 Copyright by: Aerocompact PV-Modul: Q.PRO-G3 255 121'-7.41'' 67'-1.57'' 120'-11.54'' 69'-1.63'' F FF F G G G G H Area : 0 Area : 1 Area : 2 Area : 3 Area : 4 Area : 5 Area : 6 Area : 7 Area : 8 Area : 9 Area : 10 Area : 11 Area : 12 Area : 13 Area : 14 Area : 15 Area : 16 Area : 17 Area : 18 Area : 19 Area : 20 Area : 21 Area : 22 Area : 23 Area : 24 Area : 25 Area : 26 Area : 27 Area : 28 Area : 29 Area : 30 Area : 31 Area : 32 Area : 33 Area : 34 Area : 35 Area : 36 Area : 37 Area : 38 Area : 39 Area : 40 Area : 41 Area : 42 Area : 43 Area : 44 Area : 45 Area : 46 Area : 47 Area : 48 Area : 49 Area : 50 Area : 51 Area : 52 Area : 53 Area : 54 Area : 55 Area : 56 Area : 57 Area : 58 Area : 59 Area : 60 Area : 61 Area : 62 Area : 63 Area : 64 Area : 65 Area : 66 Area : 67 Area : 68 Area : 69 Area : 70 Area : 71 Area : 72 Area : 73 Area : 74 Area : 75 Area : 76 Area : 77 Area : 78 Area : 79 Area : 80 Area : 81 Area : 82 Area : 83 Area : 84 Area : 85 Area : 86 Area : 87 Area : 88 Area : 89 Area : 90 Area : 91 Area : 92 Area : 93 Area : 94 Area : 95 Area : 96 Area : 97 Area : 98 Area : 99 M:4 3 10 M:4 3 21 M:4 3 22 M:4 3 22 M:4 3 10 13 24 25 25 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13 13 25 25 26 13M:4 3 10 M:4 3 21 M:4 3 22 18 8 M:4 5 M:4 7 17 M:4 3 22 M:4 3 22 M:4 3 10 13 24 25 18 8 M:4 5 M:4 7 17 25 25 13 16 32 32 21 8 M:4 5 M:4 7 21 32 32 16 16 32 32 21 8 M:4 5 M:4 7 21 32 32 16 13 25 25 26 13 13 25 25 26 13 16 32 32 32 16 16 32 32 32 16 End- and middle clamps PV-Modul Areas Load 3 x 15lb 5 x 15lb 7 x 15lb 8 x 15lb 10 x 15lb 13 x 15lb 16 x 15lb 17 x 15lb 18 x 15lb 21 x 15lb 22 x 15lb 24 x 15lb 25 x 15lb 26 x 15lb 32 x 15lb Mercy Hospital Solar Project 25.5kW Please Note that this Ballast Layout has been altered. Contact Billy Arthur, MO PE for more information: 314-650-3263 bill@missourisunsolar.com
  • 32. Page 14 of 15 The surface load of the system (incl. interrow spacing) incl. Module, mounting system and ballasting is: 14.12 psf Note: The red circles indicate the brackets where the standard wind sheet is replaced by the high ballast wind sheet. The high ballast wind sheet is also used in seismic regions as a ballast tray. Safety against Uplift 1.6 Safety against Shift 1.6 Safety for Weight 0.9 Weight per ballast block [lbs] 15 | Amount Stones: 2382 Standard ASCE/SEI 7-5 System surface area [sf] 2933.30 Total weight ballasting [lb] 35730.098 Weight Module/Rack [lb] 5675.36 Total System weight [lb] 41405.436 Static calculation is based on Windtunnel Report from I.F.I. Institut für Industrieaerodynamik GmbH, Report Nr. SSS01-3 and SSS01-5 issued 04.30.2014 The analysis of load bearing capacity and serviceability for the system Aerocompact S is calculated with the following load and design: Dead load + snow + wind load: up to 2,4 kN/m² Standard-Version The structural analysis has been prepared and documented with the statics software Scia Engineer and Ansys, which are independent from the Solar.Pro.Tool. Direction definition of the Horizontal Wind-Force: Fx,k und Fy,k : orizontal components of Wind-Force in the x direction, which effects the whole Aerocompact System (Characteristic value without safety factors): Fx,k=49.84 kN Horizontal components of Wind-Force in the y direction, which effects the whole Aerocompact System (Characteristic value without safety factors): Fy,k=2.8 kN RACKING PARAMETER Mercy Hospital Solar Project 25.5kW
  • 33. Page 15 of 15 DISCLAIMER/OTHER LIABILITY 1. This current order specifies expressly no review of any information provided by Principal. Any pertinent review must be ordered expressly and separately in writing. 2. The current report is based on the documents or information and data received by Principal. 3. Therefore, this report can only be as good as the quality of the information of the Principal permits. 4. For these reasons, no liability whatsoever and no warranty for errors based on untrue information of the Principal can be assumed despite any applied due diligence. However, any liability toward third parties is excluded. 5. Contractor (Aerocompact) shall be liable toward Principal only in cases of gross negligence (intent or gross negligence) except for personal injuries. This applies equally to damages to third parties engaged by Contractor. 6. Principal is only entitled to file a claim for damages within six months from the date the damaged party gained knowledge of the damage but no later than within two years following the incident on which the claim is based. 7. Principal has the burden of proof, i.e. Principal must show that the damage is caused by Principal. 8. The structural calculation of the building components refers only to these components. 9. The Supplier is not responsible for the project-related structural soundness of the roof structure and the professional realization and installation. 10. The technical specifications are an integral part of the product. AEROCOMPACT® shall not be liable for damages caused by non-compliance with the installation instructions and particularly with the safety information and from the improper use of the products. The current Terms and Conditions, Warranty Terms and Conditions and Installation Instructions will be provided on www.aerocompact.com . 11. If the roof gravel is located directly on top of the water-bearing roof membrane, Aerocompact® cannot be placed on the gravel layer. In this case the gravel must be removed in the area of the Aerocompact® bracket. 12. Minimum compressive strength of roof insulation 0.25 Kg/cm2 exclusive Snow Load. An approval from the roof-membrane manufacturer is required. 13. Photovoltaic flat roof systems are not maintenance free. Maintenance, particular the right postion of the ballast stones and the building protection pads should be conducted annually. For exceptional high-wind events, we recommend to do a Maintenance right after the storm event. 14. Place of jurisdiction, Maricopa County, Arizona Mercy Hospital Solar Project 25.5kW