ARRAY1 ‐ STRING1:
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
28  EA  CANADIAN SOLAR CS6P‐250P MODULES
102.22 FT; R=4O5'
PROPERTY LINE
ELLEN DRIVE
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
ARRAY2 ‐ STRING2:14  EA  CANADIAN SOLAR CS6P‐250P MODULES
ARRAY2/ARRAY3/ARRAY4 ‐ STRING3: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES
62 FT; R=175'
PROPERTY LINE
119 FT
PROPERTY LINE
500 FT
PROPERTY LINE
MSP, DC/AC DISCONNECT
& MONITORING ITRON
METER LOCATION
AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 315°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 135°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
 Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES: 
Outside Face Wall Line
1
SOL‐02
APN: 164‐254‐05
SITE PLAN
1 SCALE = NONE
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL-01
NTS
0 10‐23‐2013
DRAWING NUMBER:
DRAWING DESCRIPTION:
SITE PLAN
N
SITE ADDRESS:
PROJECT NAME:
OWNER NAME:
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALDBOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
TYPICAL ELEVATION
1 SCALE = NTS
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL-02
NTS
0
DRAWING NUMBER:
DRAWING DESCRIPTION:
TYPICAL ELEVATION
5/16"X3" LAG BOLT
2X6 @ 16" O/C
LOAD BEARING WALL
2X6 @ 16" O/C
LOAD BEARING WALL
2X6 @ 16" O/C
TRANSPARENT SOLAR MODULES
SOLAR MODULES
LOAD BEARING WALL6x6 D.F. #1 POST W/ PC66 CAP TYP.
3X8 D.F. TRELLIS FRAMING @ 24" O.C
6X8 D.F. #1 HDR
Ground Leve'
IRONRIDGE END / MIDCLIPS
IRONRIDGE XRL STANDARD
RAILS AND CLAMPS
QUICKMOUNT PV
COMP. FOOTINGS
5/16"X3" LAG BOLT
ANGLE CONNECTOR
2X4 Truss Rafter @ 24" O/C
SOLAR MODULES
A
SITE ADDRESS:
PROJECT NAME:
OWNER NAME:
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALD
5/16"X3" LAG BOLT
IRONRIDGE END / MIDCLIPS
IRONRIDGE XRL STANDARD
RAILS AND CLAMPS
QUICKMOUNT PV
Trellis FOOTINGS:
ANGLE CONNECTOR
3X8 D.F. TRELLIS FRAMING @ 24" O.C  
on  6X8 D.F. #1 HDR 
on  6x6 D.F. #1 POST W/ PC66 CAP TYP.
TRANSPARENT SOLAR MODULES
10‐23‐2013
BOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
PV ARRAY
SITE ADDRESS:
PROJECT NAME:
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL‐03
OWNER NAME:
DRAWING NUMBER:
DRAWING DESCRIPTION:
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
NTS
0
LAYOUT
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALD
Outside Face Wall Line
ARRAY1 ‐ STRING1:
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
28  EA  CANADIAN SOLAR CS6P‐250P MODULES
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES
ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES
MSP, DC/AC DISCONNECT
& MONITORING ITRON
METER LOCATION
AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 315°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 135°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
 Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES: 
ROOF RIDE
ROOF EAVE
3/4" EMT
1/2" EMT
VENT
VENT
VENT
1
SOL‐02
PV ARRAY LAYOUT
1 SCALE: NTS
N
10‐23‐2013
BOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
PV FOOTING
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL‐04
DRAWING NUMBER:
DRAWING DESCRIPTION:
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
NTS
0
LAYOUT
Outside Face Wall Line
ARRAY1 ‐ STRING1:
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
28  EA  CANADIAN SOLAR CS6P‐250P MODULES
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES
ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES
MSP,DC/AC DISCONNECT
& MONITORING ITRON
METER LOCATIONAZIMUTH 225°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 315°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 135°+/‐ (TRUE SOUTH=180°)
ROOF MOUNTED FLUSHED 
14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
ON 18° ROOF SLOPE;
ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
 Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES: 
ROOF RIDGE
QTY. TOTAL= 62
QUICKMOUNT PV
COMP. FOOTINGS
5/16"X3" LAG BOLT
2x4 TRUSS @ 24" O/C
2x4 TRUSS @ 24" O/C
2x4 TRUSS @ 24" O/C
ROOF EAVE
VENT
VENT
VENT
6x6 D.F. #1 POST W/ PC66 CAP TYP.
6X8 D.F. #1 HDR
3X8 D.F. TRELLIS FRAMING @ 24" O.C
1
SOL‐02
PV RACKING LAYOUT
1 SCALE: NTS
N
A
SITE ADDRESS:
PROJECT NAME:
OWNER NAME:
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALD
10‐23‐2013
BOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
PV RACKING
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL‐05
DRAWING NUMBER:
DRAWING DESCRIPTION:
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
NTS
0
LAYOUT
Max Cantilver Recommended is 1'8"
Outside Face Wall Line
ARRAY1 ‐ STRING1:
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
28  EA  CANADIAN SOLAR CS6P‐250P MODULES
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES: MUNTED ON TRELLIS
ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES: MOUNTED ON ROOF COMP.
ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES: MOUNTED ON ROOF COMP>
MSP, 
DC/AC DISCONNECT
& MONITORING ITRON
METER LOCATION
ROOF RIDE
ROOF EAVE
QTY. TOTAL= 62
QUICKMOUNT PV
COMP. FOOTINGS
5/16"X3" LAG BOLT
IRON RIDGE RAIL 
RAIL SPLICE
RAIL SPLICE
RAIL SPLICEIRON RIDGE RAIL 
ARRAY 1: ON TRELLIS
ARRAY 2: ON ROOF A: COMP.
ARRAY 3: ON ROOF B: COMP.
ARRAY 4: ON ROOF C: COMP.
ABC
RAIL 
SPLICE
IRON 
RIDGE 
RAIL 
IRON 
RAIL 
RIDGE 
2x4 TRUSS @ 24" O/C
2x4 TRUSS @ 24" O/C
2x4 TRUSS @ 24" O/C
3X8 D.F. TRELLIS FRAMING @ 24" O.C
6x6 D.F. #1 POST W/ PC66 CAP TYP.
6X8 D.F. #1 HDR
1
SOL‐02
N
PV RACKING LAYOUT
1 SCALE: NTS
ARRAY3 ‐ ROOF C: COMP.
MODULE WEIGHT:
MODULE LENGTH:
MODULE WIDTH:
MODULE DEPTH:
TOTAL MODULES:
SUM= MODULES WEIGHT:
INSTALLATION WEIGHT:
INSTALLATION AREA:
POINT QTY / AVG LOAD:
41.9 LBS
64.5 INCHES
38.7 INCHES
1.57 INCHES
335.28 LBS
440.69 LBS
138.68 FT²
DISTRIBUTED LOAD:
ROOF C
8 EA.
ARRAY3 ‐ ROOF B: COMP.
MODULE WEIGHT:
MODULE LENGTH:
MODULE WIDTH:
MODULE DEPTH:
TOTAL MODULES:
SUM= MODULES WEIGHT:
INSTALLATION WEIGHT:
INSTALLATION AREA:
POINT QTY / AVG LOAD:
41.9 LBS
64.5 INCHES
38.7 INCHES
1.57 INCHES
125.73 LBS
165.26 LBS
52.00 FT²
DISTRIBUTED LOAD:
ROOF B
3 EA.
ARRAY2 ‐ ROOF A: COMP.
MODULE WEIGHT:
MODULE LENGTH:
MODULE WIDTH:
MODULE DEPTH:
TOTAL MODULES:
SUM= MODULES WEIGHT:
INSTALLATION WEIGHT:
INSTALLATION AREA:
POINT QTY / AVG LOAD:
41.9 LBS
64.5 INCHES
38.7 INCHES
1.57 INCHES
712.47 LBS
936.46 LBS
294.68 FT²
DISTRIBUTED LOAD: 3.18 LBS/FT²
36.02 LBS
ROOF A
17 EA.
ARRAY1 ‐ ON TRELLIS
MODULE WEIGHT:
MODULE LENGTH:
MODULE WIDTH:
MODULE DEPTH:
TOTAL MODULES:
SUM= MODULES WEIGHT:
SUM= MOUNTS, RAILS & MICRO‐INVERTERS
INSTALLATION WEIGHT:
INSTALLATION AREA:
POINT QTY / AVG LOAD:
46.7 LBS
65.94 INCHES
39.41 INCHES
1.22 INCHES
653.80 LBS
184.46 LBS
838.26 LBS
252.65 FT²
DISTRIBUTED LOAD: 3.32 LBS/FT²
41.91 LBS
14
MICR‐INVERTER WEIGHT:
TOTAL MICRO‐INVERTERS:
ROOF1
14 EA.
3.5 LBS
SUM= MOUNTS, RAILS & MICRO‐INVERTERS 223.99.16 LBS
17
MICR‐INVERTER WEIGHT:
TOTAL MICRO‐INVERTERS:
3.5 LBS
SUM= MOUNTS, RAILS & MICRO‐INVERTERS 39.53 LBS
3
MICR‐INVERTER WEIGHT:
TOTAL MICRO‐INVERTERS:
3.5 LBS
SUM= MOUNTS, RAILS & MICRO‐INVERTERS 105.41 LBS
8
MICR‐INVERTER WEIGHT:
TOTAL MICRO‐INVERTERS:
3.5 LBS
3.18 LBS/FT²
27.54 LBS
3.18 LBS/FT²
44.07 LBS
A
SITE ADDRESS:
PROJECT NAME:
OWNER NAME:
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALD
10‐23‐2013
BOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
PV STRING
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL‐06
DRAWING NUMBER:
DRAWING DESCRIPTION:
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
NTS
0
LAYOUT
A
SITE ADDRESS:
PROJECT NAME:
OWNER NAME:
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALD
10‐23‐2013
BOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
Outside Face Wall Line
ARRAY1 ‐ STRING1:
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
28  EA  CANADIAN SOLAR CS6P‐250P MODULES
14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES
ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES
ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES
MSP, DC/AC DISCONNECT
& MONITORING ITRON
METER LOCATION
AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 315°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P
3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL 
AZIMUTH 135°+/‐ (TRUE SOUTH=180°)
ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED 
ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)
 Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES: 
ROOF RIDE
ROOF EAVE
3/4" EMT
1/2" EMT
TYP. 6" J‐BOX
1/2" EMT
TYP. 6" J‐BOX
TYP. 6" J‐BOX
VENT
VENT
VENT
1
SOL‐02
PV STRING LAYOUT
1 SCALE: NTS
N
ELECTRICAL LINE DIAGRAM
1 SCALE = NONE
SCALE:
DRAWN BY:
SYSTEM TYPE
ENGINEER:
REV: DATE:
SOL-07
DRAWING NUMBER:
ELECTRICAL LINE
DRAWING DESCRIPTION:
GRID-TIED PV SYSTEM
ABDOULIE MANNEH, Assoc. AIA
NTS
0
DIAGRAM
SITE ADDRESS:
PROJECT NAME:
OWNER NAME:
287ELLENDRIVE
SANRAFAEL,CA94903-1602
APN:164-254-05
DUBEN,RONALD
PRE‐WIRED CONNECTIONS
L1
L2
GN
DC IN
AC OUT
DC IN
L1
L2
AC OUT
GN
END CAPS INSTALLED 
ON LAST INVERTER CABLE
OF BRANCH CIRCUIT
ENPHASE M215
+‐
G
(N) J‐BOX 1
+‐
G
BRANCH CIRCUIT 3 WITH
(BC3)
PRE‐WIRED ASSEMBLY
ENPHASE AC
INTERCONNECT CABLE
L1
L2
GN
DC IN
AC OUT
DC IN
L1
L2
AC OUT
GN
+‐
G
+‐
G
BRANCH CIRCUIT 2 WITH
(BC2)
N
(MSP1)
(NEW) 200A, 120/240V SERVICE PANEL
G
METER
N G
200A
BC1, BC2 OCP =
(E) 100A
NEW SOLAR DEDICATED
INVERTER LOADCENTER
MODULES AND MICRO‐INVERTERS BONDED
TO SUPPORT RAIL VIA WEEB LUG.
CANADIAN SOLAR
250W MODULE
(1) #8 AWG NEUT.
(1) #8 AWG CU, GRND
3/4" CONDUIT MIN.
FROM ( AGAC1 ) TO ( ACDC1 )
14 ENPHASE MICRO‐INVERTERS
14 ENPHASE MICRO‐INVERTERS
(AGAC1)
(JB1)
(2) #8 AWG THHN CU
FROM ( JB1, JBL2, & JBL3) TO ( AGAC1 )
3/4" EMT
(1) #8 AWG CU, GRND
(9) #10 AWG THWN‐2 CU
END CAPS INSTALLED 
ON LAST INVERTER CABLE
OF BRANCH CIRCUIT
MICRO‐INVERTER
ENPHASE M215
MICRO‐INVERTER
ENPHASE M215
MICRO‐INVERTER
ENPHASE M215
MICRO‐INVERTER
@ #12 AWG TYP.
PRE‐WIRED CONNECTIONS
@ #12 AWG TYP.
PRE‐WIRED ASSEMBLY
ENPHASE AC
INTERCONNECT CABLE
TO PG&E
2‐POLE MAIN
EXISTING
LOADS
2‐POLE
EA. 20A 2P
G
60A FUSES, 120/240V, 3R 1PH
FUSED AC DISCO W/
60A GENERAL DUTY
SQUARE‐D ( D221NRB )
(ACDC1)
(E) GND ROD
/ GROUNDING
ELECTRODE SYSTEM
(1) #8 AWG NEUT.
(1) #8 AWG CU, GRND
3/4" CONDUIT MIN.
FROM ( ACDC1 ) TO ( SP1 )
(2) #8 AWG THHN CU
CANADIAN SOLAR
250W MODULE
100A, 120/240V SUB‐PANEL
L1
L2
GN
DC IN
AC OUT
DC IN
L1
L2
AC OUT
GN
+‐
G
+‐
G
BRANCH CIRCUIT 1 WITH
(BC1)
MODULES AND MICRO‐INVERTERS BONDED
TO SUPPORT RAIL VIA WEEB LUG.
14 ENPHASE MICRO‐INVERTERS
SOLAR WORLD 
270W MODULE 
END CAPS INSTALLED 
ON LAST INVERTER CABLE
OF BRANCH CIRCUIT
ENPHASE M215
MICRO‐INVERTER
ENPHASE M215
MICRO‐INVERTER
PRE‐WIRED CONNECTIONS
@ #12 AWG TYP.
PRE‐WIRED ASSEMBLY
ENPHASE AC
INTERCONNECT CABLE
(Semi-Transparent)
SOLAR WORLD 
270W MODULE 
(Semi-Transparent)
MODULES AND MICRO‐INVERTERS BONDED
TO SUPPORT RAIL VIA WEEB LUG.
CANADIAN SOLAR
250W MODULE
CANADIAN SOLAR
250W MODULE
INSULATION PIERCING
WIRE TAPS W/
TAP CONNECTOR
(IPS 1/O‐2 AWG OR EQUIV.)
10‐23‐2013
BOX 6162, SANTA ROSA, CA 95401
PH: 707‐528‐7652
FAX: 707‐528‐6865
CA LIC# 939082
GENERAL CONTRACTOR:
NORTHERN PACIFIC POWER SYSTEMS
INVERTER OUTPUT DATA:
SHALL BE PLACED ON EACH
AC DISCONNECT / BREAKER 
1/8" LETTERING
  LOCATED AT MAIN SERVICE POINT OF INTERCONNECTION
  3/8" WHITE LETTERING ON RED BACKING
  LOCATED AT MAIN SERVICE POINT OF INTERCONNECTION
  3/8" WHITE LETTERING ON RED BACKING
  SHALL BE PLACED EVERY 10' 
  REQUIRED ON ALL DC RACEWAYS, J‐BOXES AND ENCLOSURES
  3/8" WHITE LETTERING ON RED BACKING 
SHALL BE PLACED ON
AC COMBINER PANEL & AC DISCONNECT 
"WARNING" SHALL BE 1/4" TEXT 
ALL OTHER TEXT IS 1/8"
SHALL BE LOCATED NEXT TO CIRCUIT
BREAKER AT INTERACTIVE SYSTEM POINT
OF INTERCONNECTION 1/8" WHITE
CIRUIT OUTPUT DATA:
PANEL/BUS RATING X 1.20%=
ALL COMBINED SOURCES MUST BE < OR = 240A
LETTERING ON SOLID BACKING
CIRUIT OUTPUT DATA: PER BRANCH
SHALL BE PLACED ON EACH
AC DISCONNECT / BREAKER 
1/8" LETTERING
BRANCH CIRCUIT 1
BRANCH CIRCUIT 2
 Sunmodule Protectt SW 270 mono
CAUTION: SOLAR CIRCUIT
CAUTION: SOLAR ELECTRIC
SYSTEM CONNECTED
PV SYSTEM DISCONNECT
FOR UTILITY OPERATION
PHOTOVOLTAIC DISCONNECT
FOR UTILITY USE
       OPERATING CURRENT:
OPERATING VOLTAGE: 240 V
WARNING:
ELECTRIC SHOCK HAZARD.
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE
AND LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION.
WARNING:
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
15.3 A
PHOTOVOLTAIC DISCONNECT
FOR UTILITY USE
       OPERATING CURRENT:
OPERATING VOLTAGE: 240 V
14.4 A
MODULE SPECIFICATION
BRAND
TYPE
# OF MODULES
Voc
Vmp
Isc
Imp
CANADIAN SOLAR
CS6P‐250P
28
37.2 V
30.1 V
8.87 A
8.30 A
INVERTER SPECIFICATION
BRAND
TYPE
ENPHASE M215 MICROINVERTER
M215‐60‐2LL
AC MAXIMUM OUTPUT POWER=
AC NOMINAL VOLTAGE RANGE=
AC FREQUENCY RANGE= 60Hz
POWER FACTOR @ FULL LOAD= > 0.95
215W @ 240V
AC MAXIMUM OUTPUT CURRENT= .9A @ 240V
DISCRIPTION 250W SOLAR MODULE
17 UNITS MAX PER CIR.
211‐264V AC
BRANCH CIRCUIT 1
INVERTER QTY.
AC COMBINED OUTPUT POWER=
AC COMBINED OUTPUT CURRENT=
TOTAL POWER kW=
TOTAL OUTPUT CURRENT= 37.8A X 1.25= 47.25A 
TOTAL INVERTER QTY=
9,030W @ 240V
SOLAR SOURCE SELECTED OCPD=
200A
BC1, BC2, BC3; EA. 20A 2‐P
PG&E SOURCE BREAKER SIZE=
INTERCONNECTION LOCATION= LINE SIDE OF MAIN
200A
240A
PANEL/BUS RATING=
14
3,010W @ 240V
12.6A X 1.25= 15.75A 
BRANCH CIRCUIT 2 & BRANCH CIRCUIT 3
INVERTER QTY.
AC COMBINED OUTPUT POWER=
AC COMBINED OUTPUT CURRENT=
14 PER BRANCH
SOLAR WORLD
39.2 V
30.9 V
9.44 A
8.81 A
270W SOLAR MODULE
14
42
3,010W @ 240V
12.6A X 1.25= 15.75A 
solarworld.com
Designed to withstand heavy
accumulations of snow and ice
Every component is tested to meet
3 times IEC requirements
Sunmodule Plus:
Positive performance tolerance
25-year linear performance warranty and
10-year product warranty
-0/+5 Wp
WARRANTY
TUV Power controlled:
Lowest measuring tolerance in industry
World-class quality
Fully-automated production lines and seamless monitoring of the process and material
ensure the quality that the company sets as its benchmark for its sites worldwide.
SolarWorld Plus-Sorting
Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that
have greater than or equal to the nameplate rated power.
25 years linear performance guarantee and extension of product warranty to 10 years
SolarWorld guarantees a maximum performance degression of 0.7% p.a. in the course of
25 years, a significant added value compared to the two-phase warranties common in the
industry. In addition, SolarWorld is offering a product warranty, which has been extended
to 10 years.*
*in accordance with the applicable SolarWorld Limited Warranty at purchase.
www.solarworld.com/warranty
Plus SW 270 mono
SW-01-6004US 08-2013
1) Measuring tolerance (Pmax
) traceable to TUV Rheinland: +/- 2% (TUV Power Controlled).
THERMAL CHARACTERISTICS
NOCT 46 °C
TC Isc
0.004 %/K
TC Voc
-0.30 %/K
TC Pmpp
-0.45 %/K
Operating temperature -40°C to 85°C
PERFORMANCE AT 800 W/m², NOCT, AM 1.5
Maximum power Pmax
201.3 Wp
Open circuit voltage Voc
35.9 V
Maximum power point voltage Vmpp
28.3 V
Short circuit current Isc
7.63 A
Maximum power point current Impp
7.12 A
Minor reduction in efficiency under partial load conditions at 25°C: at 200 W/m², 100%
(+/-2%) of the STC efficiency (1000 W/m²) is achieved.
COMPONENT MATERIALS
Cells per module 60
Cell type Mono crystalline
Cell dimensions 6.14 in x 6.14 in (156 mm x 156 mm)
Front Tempered glass (EN 12150)
Frame Clear anodized aluminum
Weight 46.7 lbs (21.2 kg)
ADDITIONAL DATA
Power sorting1
-0 Wp / +5 Wp
J-Box IP65
Connector MC4
Module efficiency 16.10 %
Fire rating (UL 790) Class C
SYSTEM INTEGRATION PARAMETERS
Maximum system voltage SC II 1000 V
Max. system voltage USA NEC 600 V
Maximum reverse current 16 A
Number of bypass diodes 3
UL Design Loads* Two rail system
113 psf downward
64 psf upward
UL Design Loads* Three rail system
170 psf downward
64 psf upward
IEC Design Loads* Two rail system
113 psf downward
50 psf upward
*Please refer to the Sunmodule installation instructions for the details associated with
these load cases.
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)*
Maximum power Pmax
270 Wp
Open circuit voltage Voc
39.2 V
Maximum power point voltage Vmpp
30.9 V
Short circuit current Isc
9.44 A
Maximum power point current Impp
8.81 A
*STC: 1000 W/m², 25°C, AM 1.5
Independently created PAN files now available.
Ask your account manager for more information.
NEW!
Plus SW 270 mono
All units provided are imperial. SI units provided in parentheses.
SolarWorld AG reserves the right to make specification changes without notice.
Modulecurrent[A]
Module voltage [V]
1000 W/m²
800 W/m²
600 W/m²
400 W/m²
200 W/m²
100 W/m²
ISC
VOC
CS6P is a robust solar module with 60 solar
cells. These modules can be used for on-grid
solar applications. Our meticulous design and
production techniques ensure a high-yield,
long-term performance for every module
produced. Our rigorous quality control and
in-house testing facilities guarantee Canadian
Solar's modules meet the highest quality
standards possible.
CS6P
On-grid Module
On-grid residential roof-tops
On-grid commercial/industrial roof-tops
Solar power stations
Other on-grid applications
Applications
www.canadiansolar.com
IEC 61215, IEC 61730, UL1703, CEC Listed,
CE and MCS
ISO9001: 2008: Standards for quality
management systems
ISO/TS16949:2009: The automotive quality
management system
Quality Certificates
Key Features
Top ranked PVUSA (PTC) rating in California for higher
energy production
Industry first comprehensive warranty insurance by
AM Best rated leading insurance companies in the world
Industry leading plus only power tolerance: 0 ~ +5W
Strong framed module, passing mechanical load test
of 5400Pa to withstand heavier snow load
The 1st manufacturer in the PV industry certified for
ISO:TS16949 (The automotive quality management
system) in module production since 2003
ISO17025 qualified manufacturer owned testing lab,
fully complying to IEC, TUV, UL testing standards
ISO14001:2004: Standards for Environmental
management systems
QC080000 HSPM: The Certification for
Hazardous Substances Regulations
Environmental Certificates
10 year product warranty on materials and workmanship
25 year linear power output warranty
Backed By Our New 10/25 Linear Power Warranty
Plus our added 25 year insurance coverage
5 10 15 20 25
0%
80%
90%
97%
100%
Added Value From Warranty
230/235/240/245/250P
2
Under Standard Test Conditions (STC) of irradiance of 1000W/m , spectrum AM 1.5 and cell temperature of 25
*Specifications included in this datasheet are subject to change without prior notice.
Engineering Drawings
I-V Curves (CS6P-250P)
Temperature Coefficient
About Canadian Solar
Headquarters | 650 Riverbend Drive, Suite B
Kitchener, Ontario | Canada N2K 3S2
Tel: +1-519-954-2057
Fax: +1-519-578-2097
inquire.ca@canadiansolar.com
www.canadiansolar.com
CS6P-230/235/240/245/250P
Electrical Data
Pmax
Voc
Isc
-0.43
-0.34 %/
0.065 %/
45 2
%/
Temperature Characteristics
NOCT
Nominal Maximum Power (Pmax)
Optimum Operating Voltage (Vmp)
Optimum Operating Current (Imp)
Open Circuit Voltage (Voc)
Short Circuit (Isc)Current
2
Under Normal Operating Cell Temperature, Irradiance of 800 W/m , spectrum AM 1.5, ambient temperature 20 ,
wind speed 1 m/s
Performance at Low Irradiance
Normal Operating Cell Temperature
Mechanical Data
Cell Type
Cell Arrangement
Dimensions
Weight
Front Cover
Frame Material
J-BOX
Cable
Connectors
Standard Packaging (Modules per Pallet)
Module Pieces per container (40 ft . Container)
Industry leading performance at low irradiation
environment, +95.5% module efficiency from an
2 2
irradiance of 1000w/m to 200w/m
(AM 1.5, 25 )
EN-Rev 3.39 Copyright 2011 Canadian Solar Inc.
Canadian Solar Inc. is one of the world's largest solar
companies. As a leading vertically-integrated
manufacturer of ingots, wafers, cells, solar modules and
solar systems. Canadian Solar delivers solar power
products of uncompromising quality to worldwide
customers. Canadian Solar's world class team of
professionals works closely with our customers to
provide them with solutions for all their solar needs.
STC
Nominal Maximum Power (Pmax)
Optimum Operating Voltage (Vmp)
Optimum Operating Current (Imp)
Open Circuit Voltage (Voc)
Short Circuit (Isc)
Module Efficiency
Operating Temperature
Maximum System Voltage
Maximum Series Fuse Rating
Application Classification
Power Tolerance
Current
Canadian Solar was founded in Canada in 2001 and was
successfully listed on NASDAQ Exchange (symbol: CSIQ) in
November 2006. Canadian Solar has already expanded its
m o d u l e m a n u f a c t u r i n g c a p a c i t y t o 2 . 0 5 G W a n d c e l l
manufacturing capacity to 1.3GW in 2011.
Section B-B
Section A-A A A
BB
CS6P-230P
230W
29.6V
7.78A
36.8V
8.34A
14.30%
CS6P-235P
235W
29.8V
7.90A
36.9V
8.46A
14.61%
CS6P-240P
240W
29.9V
8.03A
37.0V
8.59A
14.92%
CS6P-245P
245W
30.0V
8.17A
37.1V
8.74A
15.23%
CS6P-250P
250W
30.1V
8.30A
37.2V
8.87A
15.54%
-40 ~+85
1000V (IEC) /600V (UL)
15A
Class A
0 ~ +5W
CS6P-230P
167W
27.0V
6.18A
33.8V
6.76A
CS6P-235P
170W
27.2V
6.27A
33.9V
6.86A
CS6P-240P
174W
27.3V
6.38A
34.0V
6.96A
CS6P-245P
178W
27.4V
6.49A
34.1V
7.08A
CS6P-250P
181W
27.5V
6.60A
34.2V
7.19A
Poly-crystalline 156 x 156mm, 2 or 3 Busbars
60 (6 x 10)
1638 x 982 x 40mm (64.5 x 38.7 x 1.57in)
20kg (44.1 lbs)
3.2mm Tempered glass
Anodized aluminium alloy
IP65, 3 diodes
4mm (IEC)/12AWG(UL), 1100mm
MC4 or MC4 Comparable
24pcs
672pcs (40'HQ)
2
The Enphase Energy Microinverter
System improves energy harvest,
increases reliability, and dramatically
simplifies design, installation and
management of solar power systems.
The Enphase System includes the
microinverter, the Envoy Communications
Gateway, and Enlighten, Enphase’s
monitoring and analysis software.
M 2 1 5 — M I C R O I N V E R T E R
enphase.com
P R O D U C T I V E
R E L I A B L E
- Maximum energy production
- Resilient to dust, debris and shading
- Performance monitoring per module
- System availability greater
than 99.8%
- No single point of system failure
S M A R T
S A F E
- Quick and simple design, installation
and management
- 24/7 monitoring and analysis
- Low voltage DC
- Reduced fire risk
Pairs with most 60-cell PV modules
Power line
25-year limited warranty
Free lifetime monitoring via Enlighten softrware
UL1741/IEEE1547, FCC Part 15 Class B
CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01
Output Data (AC)
Maximum output power
Nominal output current
Nominal voltage/range
Nominal frequency/range
Extended frequency range
Power Factor
Maximum units per 20A branch circuit
Maximum output fault current
Recommended input power (STC)
Maximum input DC voltage
Peak power tracking voltage
Operating range
Min./Max. start voltage
Max. DC short circuit current
Max. input current
CEC weighted efficiency
Peak inverter efficiency
Static MPPT efficiency (weighted, reference EN50530)
Dynamic MPPT efficiency (fast irradiation changes, reference EN50530)
Night time power consumption
Efficiency
M215 — MICROINVERTER TECHNICAL DATA
Input Data (DC) M215-60-2LL-S22/S23 and M215-60-2LL-S22-NA/S23-NA (Ontario)
190 - 260W
45V
22V - 36V
16V - 36V
26.4V/45V
15A
10.5A
215W
1.0A (arms at nominal duration)
208V/183-229V
60.0/59.3-60.5 Hz
60.0/59.2-60.6 Hz
>0.95
25 (three phase)
1.05 Arms, over 3 cycles; 25.2 Apeak, 174ms duration
215W
0.9A (arms at nominal duration)
240V/211-264V
60.0/59.3-60.5 Hz
60.0/59.2-60.6 Hz
>0.95
17 (single phase)
96.0%
96.3%
99.6%
99.3%
46mW
Mechanical Data
-40ºC to + 65ºC
-40ºC to + 85ºC
17.3 cm x 16.4 cm x 2.5 cm (6.8” x 6.45” x 1.0”)*
1.6 kg (3.5 lbs)
Natural convection - No fans
Outdoor - NEMA 6
Ambient temperature range
Operating temperature range (internal)
Dimensions (WxHxD)
Weight
Cooling
Enclosure environmental rating
Features
Compatibility
Communication
Warranty
Monitoring
Compliance
@208 Vac @240 Vac
142-00010 Rev 02
Enphase Energy, Inc.
201 1st Street
Petaluma, CA 94952
Phone: 877-797-4743
Fax: 707-763-0784
info@enphaseenergy.com
http://www.enphase.com
* without mounting bracket
SPECIFICATION SHEET
936 Detroit Ave, Suite D, Concord, Ca. 94518
Phone: (925) 687-6686 Fax: (925) 687-6689
Email: info@quickmountpv.com www.quickmountpv.com
Quick Mount PV ™ is an all-in-one waterproof flashing and mount to anchor photovoltaic
racking systems, solar thermal panels, air conditioning units, satellite dishes, or anything
you may need to secure to a new or existing roof. It is made in the USA of all aluminum
and includes stainless steel hardware. It works with all standard racks, installs
seamlessly and saves labor by not needing to cut away any roofing, will out live
galvanized 2 to 1, and is a better low-profile mount.
Lag pull-out (withdrawal) capacities (lbs) in typical lumber:
Lag screw specifications
Specific 5/16” shaft* 5/16” shaft*
gravity 3” thread depth per 1” thread depth
Douglas Fir, Larch .50 798 266
Douglas Fir, South .46 705 235
Engelmann Spruce, Lodgepole Pine
(MSR 1650 f & higher) .46 705 235
Hem, Fir .43 636 212
Hem, Fir. (North) .46 705 235
Southern Pine .55 921 307
Spruce, Pine, Fir .42 615 205
Spruce, Pine, Fir
(E of 2 million psi and higher
grades of MSR and MEL) .50 798 266
Sources: Uniform Building Code; American Wood Council
Notes: 1) Thread must be embedded in a rafter or other structural roof member.
2) Pull-out values incorporate a 1.6 safety factor recommended by the American Wood Council.
3) See UBC for required edge distances.
*Use flat washers with lag srews.
(2)
Hex Nuts
5/16”
Patent Pending
Flat Washer (B) 1” x 5/16”
Rubber Gasket 60 Durometer EPDM
Sealing Washer (A) 3/4” x 5/16”
Hanger Bolt 5/16” x 6”
1-1/2” Machine, 1-1/2” Spacer, 3” Lag
Mount & Flashing Aluminum
Mount 2-1/4”l x 1-1/4”w x 1-1/4”h
Flashing .05” thick.
For standard composition roofs: flashing is 12”
x 12”, mount is attached 3” off center. For
shake roofs: flashing is 18” x 18”, mount is
attached 6” off center.
10-2007[SPECSHT]
(925)687-6686
www.quickmountpv.com
TOOLSNEEDED
Measuringtape,roofer’s
1.LOCATERAFTER
2.DRILLPILOTHOLE
Using
3.LIFTTILE
4.SEALHOLEUsing
5.SLIDEQUICKMOUNT
INTOPLACE
6.SETHANGERBOLT,
SEALINGWASHER&
NUT
7.ADDRUBBER
GASKET
8.SECURERACKINTO
PLACE,WITHFLAT
WASHER&NUT
NUT
NUT
BLACKGASKET
HANGERBOLT
FLATWASHER
SEALINGWASHER
QUICKMOUNT
FLASHING
ANDBLOCK
PATENTPENDING
INSTALLATION
INSTRUCTIONS
R
Page 1 of 10
October 28, 2008
Mr. Stewart Wentworth Project Number 108443C
QUICK MOUNT PV ICC-ES FILE # 08-09-16
1483 67th Street
Emeryville, CA 94608
Subject: Quick Mount PV Load Testing
ICC-ES AC13 & ASTM D 1761
Dear Mr. Wentworth:
As requested, Applied Materials & Engineering, Inc. (AME) has completed load-testing Quick Mount
PV system anchors for shear and tensile strength. The purpose of our testing was to evaluate the tensile
and shear load capacity of the Quick Mount PV system in a high density (Douglas Fir) and a low density
wood (Cedar).
SAMPLE DESCRIPTION
Twelve (12) 12"x12" samples were delivered to our laboratory on 10-16-08; six each for Douglas Fir
and Cedar. A copy of the installation instructions is provided in Appendix A. Typical sample photo is
provided in Appendix B.
PROCEDURES & RESULTS
Since an acceptance criterion (AC) has not been developed for this product, the samples were tested
under the direction of Mr. Yamil Moya, P.E. with ICC-ES, and in general accordance with applicable
procedures outlined in ASTM D 1761 and AC13.
a. Tensile Strength
Three samples each of the two types of wood were tested for tensile strength on October 24 & 27, 2008
using a United Universal testing machine. Samples were rigidly attached to the testing machine and a
tensile load was applied to the 5/16"x6" hanger bolt at a displacement rate 0.1 inches per minute without
shock until failure. Detailed results are provided in Table I. Based on these results, the average tensile
strength of the hanger bolt in Douglas Fir and Cedar wood species were determined to be 3934 lbs and
2214 lbs, respectively.
Page 3 of 10
TABLE I
QUICK MOUNT PV- 5/16"X6" HANGER (LAG) BOLT
TENSILE LOAD TEST RESULTS
PROJECT NUMBER 108443C
SAMPLE ID WOOD SPECIES
ULTIMATE LOAD
IN TENSION (LBS)
FAILURE MODE
T-DF-1 Douglas Fir 3963 Lag bolt pulled out
T-DF-2 Douglas Fir 4074 Lag bolt pulled out
T-DF-3 Douglas Fir 3764 Lag bolt pulled out
Average 3934
T-C-1 Cedar 2096 Lag bolt pulled out
T-C-2 Cedar 2004 Lag bolt pulled out
T-C-3 Cedar 2543 Lag bolt pulled out
Average 2214
Page 4 of 10
TABLE II
QUICK MOUNT PV- 5/16"X6" HANGER (LAG) BOLT
SHEAR LOAD TEST RESULTS
PROJECT NUMBER 108443C
SAMPLE ID WOOD SPECIES
ULTIMATE LOAD
IN SHEAR (LBS)
FAILURE MODE
S-DF-1 Douglas Fir 4306 Bent lag bolt
S-DF-2 Douglas Fir 3990 Bent lag bolt
S-DF-1(A) Douglas Fir 4799 Bent lag bolt
Average 4365
S-C-1 Cedar 3214 Bent lag bolt
S-C-2 Cedar 3456 Bent lag bolt
S-C-3 Cedar 3268 Bent lag bolt
Average 3313
Page 5 of 10
FIGURE I
QUICK MOUNT PV LOAD TEST SETUP
PROJECT NUMBER 108443C
a. Shear Test b. Tension Test
Page 6 of 10
FIGURE 2
QUICK MOUNT PV TYPICAL FAILURE MODE
PROJECT NUMBER 108443C
a. Shear Failure
a. Tension Failure
Page 7 of 10
APPENDIX A
Page 8 of 10
Page 9 of 10
APPENDIX B
Page 10 of 10
Roof Mounts
Splices (Internal)
· C
· Do
IronRidge Standard Rail
· Engineered p
· Ca
· A
IronRidge Light Rail
· Li
· Ca
IronRidge Standard Rails L
IronRidge Roof Mount System
Key Features
Longest Spans In The Industry Means
Backed By Industry Leading Warranty
Universal Clamping Components
Best Customer Service And Support
Solar Mounting Made Simple
IronRidge Roof Mounts are
the highest quality and
fastest system for solar panel
installers. Our customers
appreciate the professional
appearance found exlusively
with IronRidge rail profiles.
*
· A
· A
· a
· Tilt s
Clamps
·
· M
·
or t-bolt
· stainless steel
Wire Clips
Ac
Solar Mounting Made Simple
8
8
Maximum Span Chart: IronRidge Standard Rail
8
IronRidge Light Rail
· Video Tutorials
·
·
·
·
·
Single Source
a
C - Customer
Why IronRidge
Sales: 800-227-9523
Application Note
Copyright Enphase Energy, Inc. 2010 Rev 3 Last Updated 06/22/10
Compatible Racking Makes/Models for Mounting
Enphase Microinverters
Purpose
This document is not intended to be an exclusive list of racking manufacturers. It lists
products that have been verified either through field installations or the evaluation of
actual racking samples in the Enphase mechanical lab. Section 1 lists products that work
without modification, using the racking manufacturer’s standard hardware. Section 2
includes products that are known to work after modification or by adding a custom
adapter. Section 3 lists manufacturers that are shipping the Enphase Microinverter as
part of a factory assembled proprietary racking/module solution.
Grounding Options
The ground clamp provided on the mounting flange of the Enphase Microinverter accepts
#10 through #6 AWG grounding electrode conductors. As an alternative to installing a
continuous grounding electrode conductor connected to each Microinverter chassis, a
grounding washer may be used to ground the Microinverter to grounded racking.
CSA recently completed the evaluation and approval of the Wiley Electronics “WEEB”
grounding washers for use with the Enphase Microinverter. Where the compatible
racking models have listed grounding washers available, the Wiley Electronics part
numbers have been included in the tables below.
Section 1 - No Modification Required
AEE
Module Rail Fastener Information Grounding Washer
SnapNRack Slide nut with 5/16 hex head
bolt
WEEB-PMC
Conergy
Module Rail Fastener Information Grounding Washer
Suntop Quickstone slide nut with M8
socket head cap screw
WEEB-CMC
Direct Power and Water
Module Rail Fastener Information Grounding Washer
Power Rail ¼” hex head bolt, washer,
nut, for top rail mount
WEEB-DMC
Copyright Enphase Energy Inc. 2010 Rev 3 Last Updated 06/22/10
IronRidge
Module Rail Fastener Information Grounding Washer
Light Rail XRL ¼” hex head bolt, washer,
nut, for top rail mount
WEEB-DMC
Standard Rail XRS ¼” hex head bolt, washer,
nut, for top rail mount
WEEB-DMC
Krannich Solar
Module Rail Fastener Information Grounding Washer
K2 Systems Slide nut with M8 socket head
cap screw
WEEB-KMC
mounts4solar
Module Rail Fastener Information Grounding Washer
Rail 6.0 M8 SS Hammer Head Bolt
NCP Solar
Module Rail Fastener Information Grounding Washer
Slide nut with 5/16” socket
head cap screw
WEEB-11.5
ProSolar
Module Rail Fastener Information Grounding Washer
Rooftrac Slide nut with 5/16” hex head
bolt
WEEB-PMC
Schuco
Module Rail Fastener Information Grounding Washer
SolarEZ ezUniversal Screws (M8x14)
ezAnchor Blocks
WEEB-SMC
Designs Assignment commissioned by a Solar Contractor in Sonoma County
Designs Assignment commissioned by a Solar Contractor in Sonoma County

More Related Content

What's hot

What's hot (7)

Transistion from TVSS to SPD
Transistion from TVSS to SPDTransistion from TVSS to SPD
Transistion from TVSS to SPD
 
L13 ic based triggering circuit
L13 ic based triggering circuitL13 ic based triggering circuit
L13 ic based triggering circuit
 
tca785
tca785tca785
tca785
 
Simulation 2
Simulation 2Simulation 2
Simulation 2
 
FET Biasing
FET BiasingFET Biasing
FET Biasing
 
Differentiator
DifferentiatorDifferentiator
Differentiator
 
Mvar management
Mvar managementMvar management
Mvar management
 

Viewers also liked

Commercial Design Considerations & Solectria Solutions
Commercial Design Considerations & Solectria Solutions Commercial Design Considerations & Solectria Solutions
Commercial Design Considerations & Solectria Solutions Claude Colp
 
Mercy 25.5kW Planset R1
Mercy 25.5kW Planset R1Mercy 25.5kW Planset R1
Mercy 25.5kW Planset R1David Hults
 
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2David Hults
 
Filosofía de la enfermedad
Filosofía de la enfermedadFilosofía de la enfermedad
Filosofía de la enfermedadSegundo Bueno
 
In_the_Line_of_Fire_with_US_Army_Medevac
In_the_Line_of_Fire_with_US_Army_MedevacIn_the_Line_of_Fire_with_US_Army_Medevac
In_the_Line_of_Fire_with_US_Army_Medevac☆Amy Gallagher☆
 
Las TIC y los nuevos escenarios educativos (II)
Las TIC y los nuevos escenarios educativos (II)Las TIC y los nuevos escenarios educativos (II)
Las TIC y los nuevos escenarios educativos (II)Abikasumi
 
Todo la-monografia
Todo la-monografiaTodo la-monografia
Todo la-monografiaWilmerquito1
 
A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...
A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...
A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...Malene Fogh Bang
 
Training Catalog-India
Training Catalog-IndiaTraining Catalog-India
Training Catalog-IndiaVineet Sethi
 
Tses Plass Presentation
Tses Plass PresentationTses Plass Presentation
Tses Plass PresentationSimon Kapenda
 
Revista Nuestras Cosas 2011-2012
Revista Nuestras Cosas 2011-2012Revista Nuestras Cosas 2011-2012
Revista Nuestras Cosas 2011-2012Blogclavijo
 
Manual de Instrucciones ESCARIFICADOR BENZA er45 73
Manual de Instrucciones ESCARIFICADOR BENZA er45 73Manual de Instrucciones ESCARIFICADOR BENZA er45 73
Manual de Instrucciones ESCARIFICADOR BENZA er45 73Benza
 
Zylog Systems (Canada) Ltd
Zylog Systems (Canada) LtdZylog Systems (Canada) Ltd
Zylog Systems (Canada) LtdJohn Mehrmann
 
HbbTV aplicaciones
HbbTV aplicacionesHbbTV aplicaciones
HbbTV aplicacionesLTIM_UIB
 
Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...
Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...
Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...Juan Lozano Berzosa
 
Presentación Bold Bureau
Presentación Bold BureauPresentación Bold Bureau
Presentación Bold Bureauvicentemalo
 

Viewers also liked (20)

Commercial Design Considerations & Solectria Solutions
Commercial Design Considerations & Solectria Solutions Commercial Design Considerations & Solectria Solutions
Commercial Design Considerations & Solectria Solutions
 
Mercy 25.5kW Planset R1
Mercy 25.5kW Planset R1Mercy 25.5kW Planset R1
Mercy 25.5kW Planset R1
 
Solar panel
Solar panelSolar panel
Solar panel
 
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
Greenfield HS-JH 230.88kW Planset Final - Asbuilt 2
 
Filosofía de la enfermedad
Filosofía de la enfermedadFilosofía de la enfermedad
Filosofía de la enfermedad
 
Xylometazoline 526-36-3-api
Xylometazoline 526-36-3-apiXylometazoline 526-36-3-api
Xylometazoline 526-36-3-api
 
In_the_Line_of_Fire_with_US_Army_Medevac
In_the_Line_of_Fire_with_US_Army_MedevacIn_the_Line_of_Fire_with_US_Army_Medevac
In_the_Line_of_Fire_with_US_Army_Medevac
 
Las TIC y los nuevos escenarios educativos (II)
Las TIC y los nuevos escenarios educativos (II)Las TIC y los nuevos escenarios educativos (II)
Las TIC y los nuevos escenarios educativos (II)
 
Todo la-monografia
Todo la-monografiaTodo la-monografia
Todo la-monografia
 
A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...
A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...
A Walk on the Wild Side. Exploring the Compatibility of Biodiversity and Recr...
 
Training Catalog-India
Training Catalog-IndiaTraining Catalog-India
Training Catalog-India
 
Tses Plass Presentation
Tses Plass PresentationTses Plass Presentation
Tses Plass Presentation
 
Revista Nuestras Cosas 2011-2012
Revista Nuestras Cosas 2011-2012Revista Nuestras Cosas 2011-2012
Revista Nuestras Cosas 2011-2012
 
Manual de Instrucciones ESCARIFICADOR BENZA er45 73
Manual de Instrucciones ESCARIFICADOR BENZA er45 73Manual de Instrucciones ESCARIFICADOR BENZA er45 73
Manual de Instrucciones ESCARIFICADOR BENZA er45 73
 
Zylog Systems (Canada) Ltd
Zylog Systems (Canada) LtdZylog Systems (Canada) Ltd
Zylog Systems (Canada) Ltd
 
Accordance sc 2
Accordance sc 2Accordance sc 2
Accordance sc 2
 
Posicionamiento en buscadores SEO y SEM
Posicionamiento en buscadores SEO y SEMPosicionamiento en buscadores SEO y SEM
Posicionamiento en buscadores SEO y SEM
 
HbbTV aplicaciones
HbbTV aplicacionesHbbTV aplicaciones
HbbTV aplicaciones
 
Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...
Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...
Tetma, técnicas y tratamientos medio ambientales, residuos, ecoparques, plan...
 
Presentación Bold Bureau
Presentación Bold BureauPresentación Bold Bureau
Presentación Bold Bureau
 

Designs Assignment commissioned by a Solar Contractor in Sonoma County

  • 1. ARRAY1 ‐ STRING1: 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES 28  EA  CANADIAN SOLAR CS6P‐250P MODULES 102.22 FT; R=4O5' PROPERTY LINE ELLEN DRIVE 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES ARRAY2 ‐ STRING2:14  EA  CANADIAN SOLAR CS6P‐250P MODULES ARRAY2/ARRAY3/ARRAY4 ‐ STRING3: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES 62 FT; R=175' PROPERTY LINE 119 FT PROPERTY LINE 500 FT PROPERTY LINE MSP, DC/AC DISCONNECT & MONITORING ITRON METER LOCATION AZIMUTH 225°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 315°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 135°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)  Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES:  Outside Face Wall Line 1 SOL‐02 APN: 164‐254‐05 SITE PLAN 1 SCALE = NONE GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL-01 NTS 0 10‐23‐2013 DRAWING NUMBER: DRAWING DESCRIPTION: SITE PLAN N SITE ADDRESS: PROJECT NAME: OWNER NAME: 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALDBOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS
  • 2. TYPICAL ELEVATION 1 SCALE = NTS GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL-02 NTS 0 DRAWING NUMBER: DRAWING DESCRIPTION: TYPICAL ELEVATION 5/16"X3" LAG BOLT 2X6 @ 16" O/C LOAD BEARING WALL 2X6 @ 16" O/C LOAD BEARING WALL 2X6 @ 16" O/C TRANSPARENT SOLAR MODULES SOLAR MODULES LOAD BEARING WALL6x6 D.F. #1 POST W/ PC66 CAP TYP. 3X8 D.F. TRELLIS FRAMING @ 24" O.C 6X8 D.F. #1 HDR Ground Leve' IRONRIDGE END / MIDCLIPS IRONRIDGE XRL STANDARD RAILS AND CLAMPS QUICKMOUNT PV COMP. FOOTINGS 5/16"X3" LAG BOLT ANGLE CONNECTOR 2X4 Truss Rafter @ 24" O/C SOLAR MODULES A SITE ADDRESS: PROJECT NAME: OWNER NAME: 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALD 5/16"X3" LAG BOLT IRONRIDGE END / MIDCLIPS IRONRIDGE XRL STANDARD RAILS AND CLAMPS QUICKMOUNT PV Trellis FOOTINGS: ANGLE CONNECTOR 3X8 D.F. TRELLIS FRAMING @ 24" O.C   on  6X8 D.F. #1 HDR  on  6x6 D.F. #1 POST W/ PC66 CAP TYP. TRANSPARENT SOLAR MODULES 10‐23‐2013 BOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS
  • 3. PV ARRAY SITE ADDRESS: PROJECT NAME: SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL‐03 OWNER NAME: DRAWING NUMBER: DRAWING DESCRIPTION: GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA NTS 0 LAYOUT 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALD Outside Face Wall Line ARRAY1 ‐ STRING1: 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES 28  EA  CANADIAN SOLAR CS6P‐250P MODULES 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES MSP, DC/AC DISCONNECT & MONITORING ITRON METER LOCATION AZIMUTH 225°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 315°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 135°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)  Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES:  ROOF RIDE ROOF EAVE 3/4" EMT 1/2" EMT VENT VENT VENT 1 SOL‐02 PV ARRAY LAYOUT 1 SCALE: NTS N 10‐23‐2013 BOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS
  • 4. PV FOOTING SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL‐04 DRAWING NUMBER: DRAWING DESCRIPTION: GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA NTS 0 LAYOUT Outside Face Wall Line ARRAY1 ‐ STRING1: 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES 28  EA  CANADIAN SOLAR CS6P‐250P MODULES 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES MSP,DC/AC DISCONNECT & MONITORING ITRON METER LOCATIONAZIMUTH 225°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 315°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 135°+/‐ (TRUE SOUTH=180°) ROOF MOUNTED FLUSHED  14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  ON 18° ROOF SLOPE; ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)  Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES:  ROOF RIDGE QTY. TOTAL= 62 QUICKMOUNT PV COMP. FOOTINGS 5/16"X3" LAG BOLT 2x4 TRUSS @ 24" O/C 2x4 TRUSS @ 24" O/C 2x4 TRUSS @ 24" O/C ROOF EAVE VENT VENT VENT 6x6 D.F. #1 POST W/ PC66 CAP TYP. 6X8 D.F. #1 HDR 3X8 D.F. TRELLIS FRAMING @ 24" O.C 1 SOL‐02 PV RACKING LAYOUT 1 SCALE: NTS N A SITE ADDRESS: PROJECT NAME: OWNER NAME: 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALD 10‐23‐2013 BOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS
  • 5. PV RACKING SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL‐05 DRAWING NUMBER: DRAWING DESCRIPTION: GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA NTS 0 LAYOUT Max Cantilver Recommended is 1'8" Outside Face Wall Line ARRAY1 ‐ STRING1: 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES 28  EA  CANADIAN SOLAR CS6P‐250P MODULES 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES: MUNTED ON TRELLIS ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES: MOUNTED ON ROOF COMP. ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES: MOUNTED ON ROOF COMP> MSP,  DC/AC DISCONNECT & MONITORING ITRON METER LOCATION ROOF RIDE ROOF EAVE QTY. TOTAL= 62 QUICKMOUNT PV COMP. FOOTINGS 5/16"X3" LAG BOLT IRON RIDGE RAIL  RAIL SPLICE RAIL SPLICE RAIL SPLICEIRON RIDGE RAIL  ARRAY 1: ON TRELLIS ARRAY 2: ON ROOF A: COMP. ARRAY 3: ON ROOF B: COMP. ARRAY 4: ON ROOF C: COMP. ABC RAIL  SPLICE IRON  RIDGE  RAIL  IRON  RAIL  RIDGE  2x4 TRUSS @ 24" O/C 2x4 TRUSS @ 24" O/C 2x4 TRUSS @ 24" O/C 3X8 D.F. TRELLIS FRAMING @ 24" O.C 6x6 D.F. #1 POST W/ PC66 CAP TYP. 6X8 D.F. #1 HDR 1 SOL‐02 N PV RACKING LAYOUT 1 SCALE: NTS ARRAY3 ‐ ROOF C: COMP. MODULE WEIGHT: MODULE LENGTH: MODULE WIDTH: MODULE DEPTH: TOTAL MODULES: SUM= MODULES WEIGHT: INSTALLATION WEIGHT: INSTALLATION AREA: POINT QTY / AVG LOAD: 41.9 LBS 64.5 INCHES 38.7 INCHES 1.57 INCHES 335.28 LBS 440.69 LBS 138.68 FT² DISTRIBUTED LOAD: ROOF C 8 EA. ARRAY3 ‐ ROOF B: COMP. MODULE WEIGHT: MODULE LENGTH: MODULE WIDTH: MODULE DEPTH: TOTAL MODULES: SUM= MODULES WEIGHT: INSTALLATION WEIGHT: INSTALLATION AREA: POINT QTY / AVG LOAD: 41.9 LBS 64.5 INCHES 38.7 INCHES 1.57 INCHES 125.73 LBS 165.26 LBS 52.00 FT² DISTRIBUTED LOAD: ROOF B 3 EA. ARRAY2 ‐ ROOF A: COMP. MODULE WEIGHT: MODULE LENGTH: MODULE WIDTH: MODULE DEPTH: TOTAL MODULES: SUM= MODULES WEIGHT: INSTALLATION WEIGHT: INSTALLATION AREA: POINT QTY / AVG LOAD: 41.9 LBS 64.5 INCHES 38.7 INCHES 1.57 INCHES 712.47 LBS 936.46 LBS 294.68 FT² DISTRIBUTED LOAD: 3.18 LBS/FT² 36.02 LBS ROOF A 17 EA. ARRAY1 ‐ ON TRELLIS MODULE WEIGHT: MODULE LENGTH: MODULE WIDTH: MODULE DEPTH: TOTAL MODULES: SUM= MODULES WEIGHT: SUM= MOUNTS, RAILS & MICRO‐INVERTERS INSTALLATION WEIGHT: INSTALLATION AREA: POINT QTY / AVG LOAD: 46.7 LBS 65.94 INCHES 39.41 INCHES 1.22 INCHES 653.80 LBS 184.46 LBS 838.26 LBS 252.65 FT² DISTRIBUTED LOAD: 3.32 LBS/FT² 41.91 LBS 14 MICR‐INVERTER WEIGHT: TOTAL MICRO‐INVERTERS: ROOF1 14 EA. 3.5 LBS SUM= MOUNTS, RAILS & MICRO‐INVERTERS 223.99.16 LBS 17 MICR‐INVERTER WEIGHT: TOTAL MICRO‐INVERTERS: 3.5 LBS SUM= MOUNTS, RAILS & MICRO‐INVERTERS 39.53 LBS 3 MICR‐INVERTER WEIGHT: TOTAL MICRO‐INVERTERS: 3.5 LBS SUM= MOUNTS, RAILS & MICRO‐INVERTERS 105.41 LBS 8 MICR‐INVERTER WEIGHT: TOTAL MICRO‐INVERTERS: 3.5 LBS 3.18 LBS/FT² 27.54 LBS 3.18 LBS/FT² 44.07 LBS A SITE ADDRESS: PROJECT NAME: OWNER NAME: 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALD 10‐23‐2013 BOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS
  • 6. PV STRING SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL‐06 DRAWING NUMBER: DRAWING DESCRIPTION: GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA NTS 0 LAYOUT A SITE ADDRESS: PROJECT NAME: OWNER NAME: 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALD 10‐23‐2013 BOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS Outside Face Wall Line ARRAY1 ‐ STRING1: 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES 28  EA  CANADIAN SOLAR CS6P‐250P MODULES 14 EA SOLAR WORLD 270 SEMI TRANSPARENT MODULES ARRAY2 ‐ STRING2: 14  EA  CANADIAN SOLAR CS6P‐250P MODULES ARRAY2/ARRAY3/ARRAY4 ‐ STRING3:14  EA  CANADIAN SOLAR CS6P‐250P MODULES MSP, DC/AC DISCONNECT & MONITORING ITRON METER LOCATION AZIMUTH 225°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  14 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  17 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 17 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  8 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 8 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 315°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  3 EA. CANADIAN SOLAR 250W SOLAR MODULES: CSP‐250P 3 EA. ENPHASE 215W @ 240V MICRO‐INVERTERS: M215‐60‐2LL  AZIMUTH 135°+/‐ (TRUE SOUTH=180°) ON 18° ROOF SLOPE;ROOF MOUNTED FLUSHED  ON D.F. TRELLIS FRAMING @ 24" O/C; AZIMUTH 225°+/‐ (TRUE SOUTH=180°)  Sunmodule Protectt SW 270 mono14 EA. SOLAR WORLD Semi Transparent 270W SLAR MODULES:  ROOF RIDE ROOF EAVE 3/4" EMT 1/2" EMT TYP. 6" J‐BOX 1/2" EMT TYP. 6" J‐BOX TYP. 6" J‐BOX VENT VENT VENT 1 SOL‐02 PV STRING LAYOUT 1 SCALE: NTS N
  • 7. ELECTRICAL LINE DIAGRAM 1 SCALE = NONE SCALE: DRAWN BY: SYSTEM TYPE ENGINEER: REV: DATE: SOL-07 DRAWING NUMBER: ELECTRICAL LINE DRAWING DESCRIPTION: GRID-TIED PV SYSTEM ABDOULIE MANNEH, Assoc. AIA NTS 0 DIAGRAM SITE ADDRESS: PROJECT NAME: OWNER NAME: 287ELLENDRIVE SANRAFAEL,CA94903-1602 APN:164-254-05 DUBEN,RONALD PRE‐WIRED CONNECTIONS L1 L2 GN DC IN AC OUT DC IN L1 L2 AC OUT GN END CAPS INSTALLED  ON LAST INVERTER CABLE OF BRANCH CIRCUIT ENPHASE M215 +‐ G (N) J‐BOX 1 +‐ G BRANCH CIRCUIT 3 WITH (BC3) PRE‐WIRED ASSEMBLY ENPHASE AC INTERCONNECT CABLE L1 L2 GN DC IN AC OUT DC IN L1 L2 AC OUT GN +‐ G +‐ G BRANCH CIRCUIT 2 WITH (BC2) N (MSP1) (NEW) 200A, 120/240V SERVICE PANEL G METER N G 200A BC1, BC2 OCP = (E) 100A NEW SOLAR DEDICATED INVERTER LOADCENTER MODULES AND MICRO‐INVERTERS BONDED TO SUPPORT RAIL VIA WEEB LUG. CANADIAN SOLAR 250W MODULE (1) #8 AWG NEUT. (1) #8 AWG CU, GRND 3/4" CONDUIT MIN. FROM ( AGAC1 ) TO ( ACDC1 ) 14 ENPHASE MICRO‐INVERTERS 14 ENPHASE MICRO‐INVERTERS (AGAC1) (JB1) (2) #8 AWG THHN CU FROM ( JB1, JBL2, & JBL3) TO ( AGAC1 ) 3/4" EMT (1) #8 AWG CU, GRND (9) #10 AWG THWN‐2 CU END CAPS INSTALLED  ON LAST INVERTER CABLE OF BRANCH CIRCUIT MICRO‐INVERTER ENPHASE M215 MICRO‐INVERTER ENPHASE M215 MICRO‐INVERTER ENPHASE M215 MICRO‐INVERTER @ #12 AWG TYP. PRE‐WIRED CONNECTIONS @ #12 AWG TYP. PRE‐WIRED ASSEMBLY ENPHASE AC INTERCONNECT CABLE TO PG&E 2‐POLE MAIN EXISTING LOADS 2‐POLE EA. 20A 2P G 60A FUSES, 120/240V, 3R 1PH FUSED AC DISCO W/ 60A GENERAL DUTY SQUARE‐D ( D221NRB ) (ACDC1) (E) GND ROD / GROUNDING ELECTRODE SYSTEM (1) #8 AWG NEUT. (1) #8 AWG CU, GRND 3/4" CONDUIT MIN. FROM ( ACDC1 ) TO ( SP1 ) (2) #8 AWG THHN CU CANADIAN SOLAR 250W MODULE 100A, 120/240V SUB‐PANEL L1 L2 GN DC IN AC OUT DC IN L1 L2 AC OUT GN +‐ G +‐ G BRANCH CIRCUIT 1 WITH (BC1) MODULES AND MICRO‐INVERTERS BONDED TO SUPPORT RAIL VIA WEEB LUG. 14 ENPHASE MICRO‐INVERTERS SOLAR WORLD  270W MODULE  END CAPS INSTALLED  ON LAST INVERTER CABLE OF BRANCH CIRCUIT ENPHASE M215 MICRO‐INVERTER ENPHASE M215 MICRO‐INVERTER PRE‐WIRED CONNECTIONS @ #12 AWG TYP. PRE‐WIRED ASSEMBLY ENPHASE AC INTERCONNECT CABLE (Semi-Transparent) SOLAR WORLD  270W MODULE  (Semi-Transparent) MODULES AND MICRO‐INVERTERS BONDED TO SUPPORT RAIL VIA WEEB LUG. CANADIAN SOLAR 250W MODULE CANADIAN SOLAR 250W MODULE INSULATION PIERCING WIRE TAPS W/ TAP CONNECTOR (IPS 1/O‐2 AWG OR EQUIV.) 10‐23‐2013 BOX 6162, SANTA ROSA, CA 95401 PH: 707‐528‐7652 FAX: 707‐528‐6865 CA LIC# 939082 GENERAL CONTRACTOR: NORTHERN PACIFIC POWER SYSTEMS INVERTER OUTPUT DATA: SHALL BE PLACED ON EACH AC DISCONNECT / BREAKER  1/8" LETTERING   LOCATED AT MAIN SERVICE POINT OF INTERCONNECTION   3/8" WHITE LETTERING ON RED BACKING   LOCATED AT MAIN SERVICE POINT OF INTERCONNECTION   3/8" WHITE LETTERING ON RED BACKING   SHALL BE PLACED EVERY 10'    REQUIRED ON ALL DC RACEWAYS, J‐BOXES AND ENCLOSURES   3/8" WHITE LETTERING ON RED BACKING  SHALL BE PLACED ON AC COMBINER PANEL & AC DISCONNECT  "WARNING" SHALL BE 1/4" TEXT  ALL OTHER TEXT IS 1/8" SHALL BE LOCATED NEXT TO CIRCUIT BREAKER AT INTERACTIVE SYSTEM POINT OF INTERCONNECTION 1/8" WHITE CIRUIT OUTPUT DATA: PANEL/BUS RATING X 1.20%= ALL COMBINED SOURCES MUST BE < OR = 240A LETTERING ON SOLID BACKING CIRUIT OUTPUT DATA: PER BRANCH SHALL BE PLACED ON EACH AC DISCONNECT / BREAKER  1/8" LETTERING BRANCH CIRCUIT 1 BRANCH CIRCUIT 2  Sunmodule Protectt SW 270 mono CAUTION: SOLAR CIRCUIT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PV SYSTEM DISCONNECT FOR UTILITY OPERATION PHOTOVOLTAIC DISCONNECT FOR UTILITY USE        OPERATING CURRENT: OPERATING VOLTAGE: 240 V WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 15.3 A PHOTOVOLTAIC DISCONNECT FOR UTILITY USE        OPERATING CURRENT: OPERATING VOLTAGE: 240 V 14.4 A MODULE SPECIFICATION BRAND TYPE # OF MODULES Voc Vmp Isc Imp CANADIAN SOLAR CS6P‐250P 28 37.2 V 30.1 V 8.87 A 8.30 A INVERTER SPECIFICATION BRAND TYPE ENPHASE M215 MICROINVERTER M215‐60‐2LL AC MAXIMUM OUTPUT POWER= AC NOMINAL VOLTAGE RANGE= AC FREQUENCY RANGE= 60Hz POWER FACTOR @ FULL LOAD= > 0.95 215W @ 240V AC MAXIMUM OUTPUT CURRENT= .9A @ 240V DISCRIPTION 250W SOLAR MODULE 17 UNITS MAX PER CIR. 211‐264V AC BRANCH CIRCUIT 1 INVERTER QTY. AC COMBINED OUTPUT POWER= AC COMBINED OUTPUT CURRENT= TOTAL POWER kW= TOTAL OUTPUT CURRENT= 37.8A X 1.25= 47.25A  TOTAL INVERTER QTY= 9,030W @ 240V SOLAR SOURCE SELECTED OCPD= 200A BC1, BC2, BC3; EA. 20A 2‐P PG&E SOURCE BREAKER SIZE= INTERCONNECTION LOCATION= LINE SIDE OF MAIN 200A 240A PANEL/BUS RATING= 14 3,010W @ 240V 12.6A X 1.25= 15.75A  BRANCH CIRCUIT 2 & BRANCH CIRCUIT 3 INVERTER QTY. AC COMBINED OUTPUT POWER= AC COMBINED OUTPUT CURRENT= 14 PER BRANCH SOLAR WORLD 39.2 V 30.9 V 9.44 A 8.81 A 270W SOLAR MODULE 14 42 3,010W @ 240V 12.6A X 1.25= 15.75A 
  • 8. solarworld.com Designed to withstand heavy accumulations of snow and ice Every component is tested to meet 3 times IEC requirements Sunmodule Plus: Positive performance tolerance 25-year linear performance warranty and 10-year product warranty -0/+5 Wp WARRANTY TUV Power controlled: Lowest measuring tolerance in industry World-class quality Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than or equal to the nameplate rated power. 25 years linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance degression of 0.7% p.a. in the course of 25 years, a significant added value compared to the two-phase warranties common in the industry. In addition, SolarWorld is offering a product warranty, which has been extended to 10 years.* *in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty Plus SW 270 mono SW-01-6004US 08-2013 1) Measuring tolerance (Pmax ) traceable to TUV Rheinland: +/- 2% (TUV Power Controlled). THERMAL CHARACTERISTICS NOCT 46 °C TC Isc 0.004 %/K TC Voc -0.30 %/K TC Pmpp -0.45 %/K Operating temperature -40°C to 85°C PERFORMANCE AT 800 W/m², NOCT, AM 1.5 Maximum power Pmax 201.3 Wp Open circuit voltage Voc 35.9 V Maximum power point voltage Vmpp 28.3 V Short circuit current Isc 7.63 A Maximum power point current Impp 7.12 A Minor reduction in efficiency under partial load conditions at 25°C: at 200 W/m², 100% (+/-2%) of the STC efficiency (1000 W/m²) is achieved. COMPONENT MATERIALS Cells per module 60 Cell type Mono crystalline Cell dimensions 6.14 in x 6.14 in (156 mm x 156 mm) Front Tempered glass (EN 12150) Frame Clear anodized aluminum Weight 46.7 lbs (21.2 kg) ADDITIONAL DATA Power sorting1 -0 Wp / +5 Wp J-Box IP65 Connector MC4 Module efficiency 16.10 % Fire rating (UL 790) Class C SYSTEM INTEGRATION PARAMETERS Maximum system voltage SC II 1000 V Max. system voltage USA NEC 600 V Maximum reverse current 16 A Number of bypass diodes 3 UL Design Loads* Two rail system 113 psf downward 64 psf upward UL Design Loads* Three rail system 170 psf downward 64 psf upward IEC Design Loads* Two rail system 113 psf downward 50 psf upward *Please refer to the Sunmodule installation instructions for the details associated with these load cases. PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)* Maximum power Pmax 270 Wp Open circuit voltage Voc 39.2 V Maximum power point voltage Vmpp 30.9 V Short circuit current Isc 9.44 A Maximum power point current Impp 8.81 A *STC: 1000 W/m², 25°C, AM 1.5 Independently created PAN files now available. Ask your account manager for more information. NEW! Plus SW 270 mono All units provided are imperial. SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. Modulecurrent[A] Module voltage [V] 1000 W/m² 800 W/m² 600 W/m² 400 W/m² 200 W/m² 100 W/m² ISC VOC
  • 9. CS6P is a robust solar module with 60 solar cells. These modules can be used for on-grid solar applications. Our meticulous design and production techniques ensure a high-yield, long-term performance for every module produced. Our rigorous quality control and in-house testing facilities guarantee Canadian Solar's modules meet the highest quality standards possible. CS6P On-grid Module On-grid residential roof-tops On-grid commercial/industrial roof-tops Solar power stations Other on-grid applications Applications www.canadiansolar.com IEC 61215, IEC 61730, UL1703, CEC Listed, CE and MCS ISO9001: 2008: Standards for quality management systems ISO/TS16949:2009: The automotive quality management system Quality Certificates Key Features Top ranked PVUSA (PTC) rating in California for higher energy production Industry first comprehensive warranty insurance by AM Best rated leading insurance companies in the world Industry leading plus only power tolerance: 0 ~ +5W Strong framed module, passing mechanical load test of 5400Pa to withstand heavier snow load The 1st manufacturer in the PV industry certified for ISO:TS16949 (The automotive quality management system) in module production since 2003 ISO17025 qualified manufacturer owned testing lab, fully complying to IEC, TUV, UL testing standards ISO14001:2004: Standards for Environmental management systems QC080000 HSPM: The Certification for Hazardous Substances Regulations Environmental Certificates 10 year product warranty on materials and workmanship 25 year linear power output warranty Backed By Our New 10/25 Linear Power Warranty Plus our added 25 year insurance coverage 5 10 15 20 25 0% 80% 90% 97% 100% Added Value From Warranty 230/235/240/245/250P 2 Under Standard Test Conditions (STC) of irradiance of 1000W/m , spectrum AM 1.5 and cell temperature of 25 *Specifications included in this datasheet are subject to change without prior notice. Engineering Drawings I-V Curves (CS6P-250P) Temperature Coefficient About Canadian Solar Headquarters | 650 Riverbend Drive, Suite B Kitchener, Ontario | Canada N2K 3S2 Tel: +1-519-954-2057 Fax: +1-519-578-2097 inquire.ca@canadiansolar.com www.canadiansolar.com CS6P-230/235/240/245/250P Electrical Data Pmax Voc Isc -0.43 -0.34 %/ 0.065 %/ 45 2 %/ Temperature Characteristics NOCT Nominal Maximum Power (Pmax) Optimum Operating Voltage (Vmp) Optimum Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit (Isc)Current 2 Under Normal Operating Cell Temperature, Irradiance of 800 W/m , spectrum AM 1.5, ambient temperature 20 , wind speed 1 m/s Performance at Low Irradiance Normal Operating Cell Temperature Mechanical Data Cell Type Cell Arrangement Dimensions Weight Front Cover Frame Material J-BOX Cable Connectors Standard Packaging (Modules per Pallet) Module Pieces per container (40 ft . Container) Industry leading performance at low irradiation environment, +95.5% module efficiency from an 2 2 irradiance of 1000w/m to 200w/m (AM 1.5, 25 ) EN-Rev 3.39 Copyright 2011 Canadian Solar Inc. Canadian Solar Inc. is one of the world's largest solar companies. As a leading vertically-integrated manufacturer of ingots, wafers, cells, solar modules and solar systems. Canadian Solar delivers solar power products of uncompromising quality to worldwide customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. STC Nominal Maximum Power (Pmax) Optimum Operating Voltage (Vmp) Optimum Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit (Isc) Module Efficiency Operating Temperature Maximum System Voltage Maximum Series Fuse Rating Application Classification Power Tolerance Current Canadian Solar was founded in Canada in 2001 and was successfully listed on NASDAQ Exchange (symbol: CSIQ) in November 2006. Canadian Solar has already expanded its m o d u l e m a n u f a c t u r i n g c a p a c i t y t o 2 . 0 5 G W a n d c e l l manufacturing capacity to 1.3GW in 2011. Section B-B Section A-A A A BB CS6P-230P 230W 29.6V 7.78A 36.8V 8.34A 14.30% CS6P-235P 235W 29.8V 7.90A 36.9V 8.46A 14.61% CS6P-240P 240W 29.9V 8.03A 37.0V 8.59A 14.92% CS6P-245P 245W 30.0V 8.17A 37.1V 8.74A 15.23% CS6P-250P 250W 30.1V 8.30A 37.2V 8.87A 15.54% -40 ~+85 1000V (IEC) /600V (UL) 15A Class A 0 ~ +5W CS6P-230P 167W 27.0V 6.18A 33.8V 6.76A CS6P-235P 170W 27.2V 6.27A 33.9V 6.86A CS6P-240P 174W 27.3V 6.38A 34.0V 6.96A CS6P-245P 178W 27.4V 6.49A 34.1V 7.08A CS6P-250P 181W 27.5V 6.60A 34.2V 7.19A Poly-crystalline 156 x 156mm, 2 or 3 Busbars 60 (6 x 10) 1638 x 982 x 40mm (64.5 x 38.7 x 1.57in) 20kg (44.1 lbs) 3.2mm Tempered glass Anodized aluminium alloy IP65, 3 diodes 4mm (IEC)/12AWG(UL), 1100mm MC4 or MC4 Comparable 24pcs 672pcs (40'HQ) 2
  • 10. The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and Enlighten, Enphase’s monitoring and analysis software. M 2 1 5 — M I C R O I N V E R T E R enphase.com P R O D U C T I V E R E L I A B L E - Maximum energy production - Resilient to dust, debris and shading - Performance monitoring per module - System availability greater than 99.8% - No single point of system failure S M A R T S A F E - Quick and simple design, installation and management - 24/7 monitoring and analysis - Low voltage DC - Reduced fire risk Pairs with most 60-cell PV modules Power line 25-year limited warranty Free lifetime monitoring via Enlighten softrware UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 Output Data (AC) Maximum output power Nominal output current Nominal voltage/range Nominal frequency/range Extended frequency range Power Factor Maximum units per 20A branch circuit Maximum output fault current Recommended input power (STC) Maximum input DC voltage Peak power tracking voltage Operating range Min./Max. start voltage Max. DC short circuit current Max. input current CEC weighted efficiency Peak inverter efficiency Static MPPT efficiency (weighted, reference EN50530) Dynamic MPPT efficiency (fast irradiation changes, reference EN50530) Night time power consumption Efficiency M215 — MICROINVERTER TECHNICAL DATA Input Data (DC) M215-60-2LL-S22/S23 and M215-60-2LL-S22-NA/S23-NA (Ontario) 190 - 260W 45V 22V - 36V 16V - 36V 26.4V/45V 15A 10.5A 215W 1.0A (arms at nominal duration) 208V/183-229V 60.0/59.3-60.5 Hz 60.0/59.2-60.6 Hz >0.95 25 (three phase) 1.05 Arms, over 3 cycles; 25.2 Apeak, 174ms duration 215W 0.9A (arms at nominal duration) 240V/211-264V 60.0/59.3-60.5 Hz 60.0/59.2-60.6 Hz >0.95 17 (single phase) 96.0% 96.3% 99.6% 99.3% 46mW Mechanical Data -40ºC to + 65ºC -40ºC to + 85ºC 17.3 cm x 16.4 cm x 2.5 cm (6.8” x 6.45” x 1.0”)* 1.6 kg (3.5 lbs) Natural convection - No fans Outdoor - NEMA 6 Ambient temperature range Operating temperature range (internal) Dimensions (WxHxD) Weight Cooling Enclosure environmental rating Features Compatibility Communication Warranty Monitoring Compliance @208 Vac @240 Vac 142-00010 Rev 02 Enphase Energy, Inc. 201 1st Street Petaluma, CA 94952 Phone: 877-797-4743 Fax: 707-763-0784 info@enphaseenergy.com http://www.enphase.com * without mounting bracket
  • 11. SPECIFICATION SHEET 936 Detroit Ave, Suite D, Concord, Ca. 94518 Phone: (925) 687-6686 Fax: (925) 687-6689 Email: info@quickmountpv.com www.quickmountpv.com Quick Mount PV ™ is an all-in-one waterproof flashing and mount to anchor photovoltaic racking systems, solar thermal panels, air conditioning units, satellite dishes, or anything you may need to secure to a new or existing roof. It is made in the USA of all aluminum and includes stainless steel hardware. It works with all standard racks, installs seamlessly and saves labor by not needing to cut away any roofing, will out live galvanized 2 to 1, and is a better low-profile mount. Lag pull-out (withdrawal) capacities (lbs) in typical lumber: Lag screw specifications Specific 5/16” shaft* 5/16” shaft* gravity 3” thread depth per 1” thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir. (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: Uniform Building Code; American Wood Council Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) Pull-out values incorporate a 1.6 safety factor recommended by the American Wood Council. 3) See UBC for required edge distances. *Use flat washers with lag srews. (2) Hex Nuts 5/16” Patent Pending Flat Washer (B) 1” x 5/16” Rubber Gasket 60 Durometer EPDM Sealing Washer (A) 3/4” x 5/16” Hanger Bolt 5/16” x 6” 1-1/2” Machine, 1-1/2” Spacer, 3” Lag Mount & Flashing Aluminum Mount 2-1/4”l x 1-1/4”w x 1-1/4”h Flashing .05” thick. For standard composition roofs: flashing is 12” x 12”, mount is attached 3” off center. For shake roofs: flashing is 18” x 18”, mount is attached 6” off center. 10-2007[SPECSHT] (925)687-6686 www.quickmountpv.com TOOLSNEEDED Measuringtape,roofer’s 1.LOCATERAFTER 2.DRILLPILOTHOLE Using 3.LIFTTILE 4.SEALHOLEUsing 5.SLIDEQUICKMOUNT INTOPLACE 6.SETHANGERBOLT, SEALINGWASHER& NUT 7.ADDRUBBER GASKET 8.SECURERACKINTO PLACE,WITHFLAT WASHER&NUT NUT NUT BLACKGASKET HANGERBOLT FLATWASHER SEALINGWASHER QUICKMOUNT FLASHING ANDBLOCK PATENTPENDING INSTALLATION INSTRUCTIONS R
  • 12. Page 1 of 10 October 28, 2008 Mr. Stewart Wentworth Project Number 108443C QUICK MOUNT PV ICC-ES FILE # 08-09-16 1483 67th Street Emeryville, CA 94608 Subject: Quick Mount PV Load Testing ICC-ES AC13 & ASTM D 1761 Dear Mr. Wentworth: As requested, Applied Materials & Engineering, Inc. (AME) has completed load-testing Quick Mount PV system anchors for shear and tensile strength. The purpose of our testing was to evaluate the tensile and shear load capacity of the Quick Mount PV system in a high density (Douglas Fir) and a low density wood (Cedar). SAMPLE DESCRIPTION Twelve (12) 12"x12" samples were delivered to our laboratory on 10-16-08; six each for Douglas Fir and Cedar. A copy of the installation instructions is provided in Appendix A. Typical sample photo is provided in Appendix B. PROCEDURES & RESULTS Since an acceptance criterion (AC) has not been developed for this product, the samples were tested under the direction of Mr. Yamil Moya, P.E. with ICC-ES, and in general accordance with applicable procedures outlined in ASTM D 1761 and AC13. a. Tensile Strength Three samples each of the two types of wood were tested for tensile strength on October 24 & 27, 2008 using a United Universal testing machine. Samples were rigidly attached to the testing machine and a tensile load was applied to the 5/16"x6" hanger bolt at a displacement rate 0.1 inches per minute without shock until failure. Detailed results are provided in Table I. Based on these results, the average tensile strength of the hanger bolt in Douglas Fir and Cedar wood species were determined to be 3934 lbs and 2214 lbs, respectively.
  • 13. Page 3 of 10 TABLE I QUICK MOUNT PV- 5/16"X6" HANGER (LAG) BOLT TENSILE LOAD TEST RESULTS PROJECT NUMBER 108443C SAMPLE ID WOOD SPECIES ULTIMATE LOAD IN TENSION (LBS) FAILURE MODE T-DF-1 Douglas Fir 3963 Lag bolt pulled out T-DF-2 Douglas Fir 4074 Lag bolt pulled out T-DF-3 Douglas Fir 3764 Lag bolt pulled out Average 3934 T-C-1 Cedar 2096 Lag bolt pulled out T-C-2 Cedar 2004 Lag bolt pulled out T-C-3 Cedar 2543 Lag bolt pulled out Average 2214 Page 4 of 10 TABLE II QUICK MOUNT PV- 5/16"X6" HANGER (LAG) BOLT SHEAR LOAD TEST RESULTS PROJECT NUMBER 108443C SAMPLE ID WOOD SPECIES ULTIMATE LOAD IN SHEAR (LBS) FAILURE MODE S-DF-1 Douglas Fir 4306 Bent lag bolt S-DF-2 Douglas Fir 3990 Bent lag bolt S-DF-1(A) Douglas Fir 4799 Bent lag bolt Average 4365 S-C-1 Cedar 3214 Bent lag bolt S-C-2 Cedar 3456 Bent lag bolt S-C-3 Cedar 3268 Bent lag bolt Average 3313
  • 14. Page 5 of 10 FIGURE I QUICK MOUNT PV LOAD TEST SETUP PROJECT NUMBER 108443C a. Shear Test b. Tension Test Page 6 of 10 FIGURE 2 QUICK MOUNT PV TYPICAL FAILURE MODE PROJECT NUMBER 108443C a. Shear Failure a. Tension Failure
  • 15. Page 7 of 10 APPENDIX A Page 8 of 10
  • 16. Page 9 of 10 APPENDIX B Page 10 of 10
  • 17. Roof Mounts Splices (Internal) · C · Do IronRidge Standard Rail · Engineered p · Ca · A IronRidge Light Rail · Li · Ca IronRidge Standard Rails L IronRidge Roof Mount System Key Features Longest Spans In The Industry Means Backed By Industry Leading Warranty Universal Clamping Components Best Customer Service And Support Solar Mounting Made Simple IronRidge Roof Mounts are the highest quality and fastest system for solar panel installers. Our customers appreciate the professional appearance found exlusively with IronRidge rail profiles. * · A · A · a · Tilt s Clamps · · M · or t-bolt · stainless steel Wire Clips Ac Solar Mounting Made Simple 8 8 Maximum Span Chart: IronRidge Standard Rail 8 IronRidge Light Rail · Video Tutorials · · · · · Single Source a C - Customer Why IronRidge Sales: 800-227-9523
  • 18. Application Note Copyright Enphase Energy, Inc. 2010 Rev 3 Last Updated 06/22/10 Compatible Racking Makes/Models for Mounting Enphase Microinverters Purpose This document is not intended to be an exclusive list of racking manufacturers. It lists products that have been verified either through field installations or the evaluation of actual racking samples in the Enphase mechanical lab. Section 1 lists products that work without modification, using the racking manufacturer’s standard hardware. Section 2 includes products that are known to work after modification or by adding a custom adapter. Section 3 lists manufacturers that are shipping the Enphase Microinverter as part of a factory assembled proprietary racking/module solution. Grounding Options The ground clamp provided on the mounting flange of the Enphase Microinverter accepts #10 through #6 AWG grounding electrode conductors. As an alternative to installing a continuous grounding electrode conductor connected to each Microinverter chassis, a grounding washer may be used to ground the Microinverter to grounded racking. CSA recently completed the evaluation and approval of the Wiley Electronics “WEEB” grounding washers for use with the Enphase Microinverter. Where the compatible racking models have listed grounding washers available, the Wiley Electronics part numbers have been included in the tables below. Section 1 - No Modification Required AEE Module Rail Fastener Information Grounding Washer SnapNRack Slide nut with 5/16 hex head bolt WEEB-PMC Conergy Module Rail Fastener Information Grounding Washer Suntop Quickstone slide nut with M8 socket head cap screw WEEB-CMC Direct Power and Water Module Rail Fastener Information Grounding Washer Power Rail ¼” hex head bolt, washer, nut, for top rail mount WEEB-DMC Copyright Enphase Energy Inc. 2010 Rev 3 Last Updated 06/22/10 IronRidge Module Rail Fastener Information Grounding Washer Light Rail XRL ¼” hex head bolt, washer, nut, for top rail mount WEEB-DMC Standard Rail XRS ¼” hex head bolt, washer, nut, for top rail mount WEEB-DMC Krannich Solar Module Rail Fastener Information Grounding Washer K2 Systems Slide nut with M8 socket head cap screw WEEB-KMC mounts4solar Module Rail Fastener Information Grounding Washer Rail 6.0 M8 SS Hammer Head Bolt NCP Solar Module Rail Fastener Information Grounding Washer Slide nut with 5/16” socket head cap screw WEEB-11.5 ProSolar Module Rail Fastener Information Grounding Washer Rooftrac Slide nut with 5/16” hex head bolt WEEB-PMC Schuco Module Rail Fastener Information Grounding Washer SolarEZ ezUniversal Screws (M8x14) ezAnchor Blocks WEEB-SMC