1. Measuring Instruments Directive
for
manufacturers and end-users selling
g
and using instruments mentioned for trade
NMi Certin B.V., Bert Jan Siebesma, Account manager
2. Contents of the presentation
– Verification versus calibration
– Scope of the MID
– Declare confirmation
– Gas meters & Volume Conversion Devices
– Liquid installations
– Questions
2
7-7-2010
3. Verification versus calibration
– Custody transfer is subjected to the Metrology law
– Metrology law has restrictions of interference
– Verifications = law
– Calibrations = voluntary
3
7-7-2010
4. 27 EU Members 1. Austria
2. Belgium
3. Bulgaria
4. Cyprus
5. Czech Republic
6. Denmark
7. Estonia
8. Finland
9. France
10. Germany
11. Greece
12. Hungary
13. Ireland
14. Italy
15. Latvia
16. Lithuania
17. Luxembourg
u e bou g
18. Malta
19. Netherlands
20. Poland
21. Portugal
g
22. Romania
23. Slovakia
24. Slovenia
25. Spain
p
26. Sweden
27. United Kingdom 4
7-7-2010
5. Single European market
g p
Only 1 approval = MID for:
– 27 countries + 4 EFTA countries:
Iceland, Norway, Switzerland,
Liechtenstein
– > 450.000.000 people
– > 4.000.000 km2
– MID is in force since 30st of October
2006.
5
7-7-2010
7. Scope of MID
p
Placing on the market (1st stage)
g g
Putting into use (2nd stage)
Not f instruments already in use
for l d
New Approach Directive and is: “technology independent”
Part of the “CE-system”
Intention of Brussels: remove barriers to trade
National differences domestic / light / heavy industry,
water i
in-out etc.
Note: re-verification and inspection are still a national issue!
7
7-7-2010
8. MID Annexes
Water meters MI-001 B+F, B+D, H1
, ,
Gas meters & Volume MI-002 B+F, B+D, H1
Conversion Devices
Electricity
El t i it meters
t MI-003
MI 003 B+F, B+D,
B F B D H1
Heat meters MI-004 B+F, B+D, H1
Liquid installations MI 005
MI-005 B+F, B+D H1
B+F B+D, H1, G
Automatic MI-006 B+F, B+D, H1, G
weighing (B+E, D1,F1)
Taximeters MI-007 B+F, B+D, H1
Material measures MI-008 A1, F1, D1, E1, B+E, B+D,H
Dimensional measurement
meas rement MI-009
MI 009 B+F, B+D, H1,
B F B D H1 G
(F1, D1, E1, B+E ,H)
Exhaust gas analysers
g y MI-010 B+F, B+D, H1
8
7-7-2010
9. MID Modules
B
Type examination by Notified Body (NB)
A C D E F G H
DoC DoC to DoC to DoC to DoC to DoC DoC
TYPE TYPE TYPE TYPE
Internal QA QA QA Product Unit Full
Production Internal Production Product Verification Verification QA
control Production Process Inspection by NB by NB Control
Control
C l & testing
i
(A1) (C1) (D1) (E1) (F1) (H1)
9
7-7-2010
10. Declare conformation
On which base can one declare conformity?
1. Harmonized Standards, published in the Official
Journey (OJ)
2. Use of Normative Documents (OIML)
Gas = OIML R137 1 (GC = R140)
R137-1
Liquid = OIML R117-1
3. Opinion of Notified Body via for example:
* GROWTH (MID-procedures)
* WELMEC and so on.
Note!: Software is an issue in MID see Welmec Guide 7 2
MID, 7.2
10
7-7-2010
11. Gas “meters” and Volume Conversion
Devices
D i
- MID not applicable outside territorial waters
- MID applicable in Netherlands if < 170.000 Nm3/y
but differs from country to country
y y
- EMC / Electrical requirements
- Importance OIML R137-1
- Software importance
- Responsibility move from manufacturer to end-users
11
7-7-2010
12. Liquid “installations”
installations
- MID not applicable outside territorial waters
- MID applicable to liquid systems!
- EMC / Electrical requirements
El t i l i t
- Importance OIML R117-1
- Software importance
- Responsibility move from manufacturer to end users
end-users
12
7-7-2010
13. How to comply to MID
py
Manufacturer is responsible for:
– Conformity with MID
– Affixing CE mark (Conformité Européene)
– Affi i metrology markings
Affixing l ki
– Declaration of Conformity
M 10 0122
CE mark Metrology mark Notified body no. 13
7-7-2010
14. Transition period
p
– MID has no influence on already placed instruments
– New approvals or revisions under “old” regime not
possible when MID is in force
– After introduction MID, “old” approvals valid for
another 10 years
– Mix / match and equilty principle in Netherlands for
installed instruments
14
7-7-2010
15. Putting into use…
use
Gasmeters & EVCD = Module F or D for
1st verifications
Liquidinstallations = Module F or D for
1st verifications
ifi ti
Certified verification officer = repair, maintenance,
re-verification i N th l d only
ifi ti in Netherlands l
Producer D for parts
Pre-calibrations liquid meters as part of F / D for
liquid installations. How to handle?
15
7-7-2010
16. Curious?
For information please contact :
NMi Certin B.V.
Hugo de Grootplein 1
3314 EG Dordrecht
The Netherlands
T +31 78 633 2308
F +31 78 633 2309
E CertinSales@nmi.nl
I www.NMi.nl
www NMi nl
Account Manager Oil & Gas: Bert Jan Siebesma
Inside Sales engineer: Janneke de Kreij
Product Manager Oil & Gas: Wim Volmer
Sales Director: Paul van Enckevort