Forma Light
by
Forma Light
Forma Light is an
innovative IPL Unit
developed to treat a range of
medical-aesthetic
applications
Forma Light Highlight






Full control over electro physical parameters such as
pulse duration, pulse wide and flunce energy .
Pre setting features based on the patient skin type
Treatments for all skin type
Innovative design including touch screen
Shortest pulse duration
Forma Light Highlight








System weight just 8.9kg
Light & ergonomic Applicator
Large tip for large area treatments
Multilingual support
The highest quality in competitive price
4 colors to choose from
Forma Light
Applications









Hair Reduction
Skin Rejuvenation
Pigmented Lesion
Vascular Lesions
Skin Lightening
Onychmycosis
Acne
Applicators
IPL F- HR 590nm
IPL F- HR 650nm

IPL F- SR 530nm

IPL F-AC 440 nm

IPL B- HR 590nm
IPL B - HR* 650nm
IPL HR 590nm
IPL HR* 650nm
IPL SR 530nm

Application
up to
pulses
up to
pulses
up to
pulses
up to
pulses
up to
pulses
up to
pulses
60,000 up to
120,000 pulses
60,000 up to
120,000 pulses
60,000 up to
120,000 pulses

1.6cm2

Hair Reduction

1.6cm2

Hair Reduction

1.6cm2

1.6cm2

Skin rejuvenation,
Pigmented/Vascular
Lesions
Acne

3 cm2

Hair Reduction

3 cm2

Hair Reduction

6.5cm2

Hair Reduction

6.5cm2

Hair Reduction

6.5cm2

Skin rejuvenation,
Pigmented lesions
Intense Pulse Light -IPL Wavelength
Intense Pulse Light and
Thermal Relaxation Time - TRT


Represents the time taken for heated tissue to lose
50% of its heat through diffusion



If the light energy persists longer than TRT of the
target, heat is conduced to the surrounding tissue
leading to unwanted thermal injury. (Katsambas &
Lotti, 2003).
TRT in
Pigmented and Vascular lesions
Data & histological assessment of vessel injury strongly suggest
that pulse durations for ideal light treatment are in the
1 – 10ms region and depend on vessel diameter (Diedrickx, 1995).


Correct wavelength combine with correct TRT will achieve quick
coagulation of targeted chromophore (melanin/hemoglobin).
If TRT is exceeded, same clinical consistence is not achieved and
more treatments sessions are necessary.





Pulse wide choice is as important as that of the wavelength.
(X.Muller, Lasers for Ischemic Heart Disease,2000)
Forma Light – enjoy from all options
Innovation in Technology
Shortest pulse duration below 10 ms to in respect of Thermal
Relaxation Time parameters, and Long pulse for dark skin HR
Forma Light
Innovation in Technology
Fluence

=
[Power]
Area of Spot x Time (Pulse Duration)

(Energy Density)

Because of the short pulse reaches the highest intensity
Forma Light
Applicators
B/F HR – Hair removal
 Body and face hair removal.
 2 modes pulse of work: single, double pulse.
Technical information:
 Energy: up to 20 j/cm2.
 Wavelength: 590/650 nm
 Spot size: body 3cm²/6.5cm², face 1.6cm²
Pulse duration:
 Single: from 3 to 10 milliseconds (for 3cm² and 1.6cm²)
 Double: from 2 to 5 milliseconds (for 3cm² and 1.6cm²)
 For the 6.5cm² 20 milliseconds and up
Results after three treatments
Before

After
Results after one treatment
Before

After (one month)
Results after 3 treatments
Before

After
B/F SR –Skin Rejuvenation



Body and face Skin Rejuvenation and Fungus Treatment
2 modes of work: single pulse, double puls (single pulse
every 0.33 seconds).

Technical information:





Energy: up to 22 j/cm.
Wavelength: 530 nm
Spot size: body 3 cm²/6.5², face 1.6 cm²

Pulse duration:




Single: from 3 to 10 milliseconds (for 3cm² and 1.6cm²)
Double: from 2 to 5 milliseconds (for 3cm² and 1.6cm²)
For the 6.5cm² 20 milliseconds and up
Pigmentation & skin rejuvenation
Before

After (3 treat.)
Onychomycosis treatment
Before

After
Pigmentation & Skin rejuvenation
Before

After (3 treat.)
Combination of Peeling and IPL
3 treatments
Before

After
Hands pigmentation one treatment
Before

After
Onychomycosis (4 treatments)
Before

After
Onychomycosis (4 treatments)
Before

After
F–AC Acne treatment


Face acne treatment

Technical information:
 Energy: up to 22 j/cm.
 Wavelength: 440 nm
 Spot size: 1.6 cm2
Pulse duration:
 Single: from 2 to 6 milliseconds
 Double: from 1.5 to 3 milliseconds
Acne treatment with F-AC
Before

After
Acne treatment with IPL
Before

After
R-sonic combined with IPL-SR
under eye dark circle, 3 treatment performed once a week

Before

After (three week)
Thank You
Formatk
forma-tk.com

Laterna - Forma light presentation sequence 2012

  • 1.
  • 2.
    Forma Light Forma Lightis an innovative IPL Unit developed to treat a range of medical-aesthetic applications
  • 3.
    Forma Light Highlight      Fullcontrol over electro physical parameters such as pulse duration, pulse wide and flunce energy . Pre setting features based on the patient skin type Treatments for all skin type Innovative design including touch screen Shortest pulse duration
  • 4.
    Forma Light Highlight       Systemweight just 8.9kg Light & ergonomic Applicator Large tip for large area treatments Multilingual support The highest quality in competitive price 4 colors to choose from
  • 5.
    Forma Light Applications        Hair Reduction SkinRejuvenation Pigmented Lesion Vascular Lesions Skin Lightening Onychmycosis Acne
  • 6.
    Applicators IPL F- HR590nm IPL F- HR 650nm IPL F- SR 530nm IPL F-AC 440 nm IPL B- HR 590nm IPL B - HR* 650nm IPL HR 590nm IPL HR* 650nm IPL SR 530nm Application up to pulses up to pulses up to pulses up to pulses up to pulses up to pulses 60,000 up to 120,000 pulses 60,000 up to 120,000 pulses 60,000 up to 120,000 pulses 1.6cm2 Hair Reduction 1.6cm2 Hair Reduction 1.6cm2 1.6cm2 Skin rejuvenation, Pigmented/Vascular Lesions Acne 3 cm2 Hair Reduction 3 cm2 Hair Reduction 6.5cm2 Hair Reduction 6.5cm2 Hair Reduction 6.5cm2 Skin rejuvenation, Pigmented lesions
  • 7.
    Intense Pulse Light-IPL Wavelength
  • 8.
    Intense Pulse Lightand Thermal Relaxation Time - TRT  Represents the time taken for heated tissue to lose 50% of its heat through diffusion  If the light energy persists longer than TRT of the target, heat is conduced to the surrounding tissue leading to unwanted thermal injury. (Katsambas & Lotti, 2003).
  • 9.
    TRT in Pigmented andVascular lesions Data & histological assessment of vessel injury strongly suggest that pulse durations for ideal light treatment are in the 1 – 10ms region and depend on vessel diameter (Diedrickx, 1995).  Correct wavelength combine with correct TRT will achieve quick coagulation of targeted chromophore (melanin/hemoglobin). If TRT is exceeded, same clinical consistence is not achieved and more treatments sessions are necessary.   Pulse wide choice is as important as that of the wavelength. (X.Muller, Lasers for Ischemic Heart Disease,2000)
  • 10.
    Forma Light –enjoy from all options Innovation in Technology Shortest pulse duration below 10 ms to in respect of Thermal Relaxation Time parameters, and Long pulse for dark skin HR
  • 11.
    Forma Light Innovation inTechnology Fluence = [Power] Area of Spot x Time (Pulse Duration) (Energy Density) Because of the short pulse reaches the highest intensity
  • 12.
  • 13.
    B/F HR –Hair removal  Body and face hair removal.  2 modes pulse of work: single, double pulse. Technical information:  Energy: up to 20 j/cm2.  Wavelength: 590/650 nm  Spot size: body 3cm²/6.5cm², face 1.6cm² Pulse duration:  Single: from 3 to 10 milliseconds (for 3cm² and 1.6cm²)  Double: from 2 to 5 milliseconds (for 3cm² and 1.6cm²)  For the 6.5cm² 20 milliseconds and up
  • 14.
    Results after threetreatments Before After
  • 15.
    Results after onetreatment Before After (one month)
  • 16.
    Results after 3treatments Before After
  • 17.
    B/F SR –SkinRejuvenation   Body and face Skin Rejuvenation and Fungus Treatment 2 modes of work: single pulse, double puls (single pulse every 0.33 seconds). Technical information:    Energy: up to 22 j/cm. Wavelength: 530 nm Spot size: body 3 cm²/6.5², face 1.6 cm² Pulse duration:    Single: from 3 to 10 milliseconds (for 3cm² and 1.6cm²) Double: from 2 to 5 milliseconds (for 3cm² and 1.6cm²) For the 6.5cm² 20 milliseconds and up
  • 18.
    Pigmentation & skinrejuvenation Before After (3 treat.)
  • 19.
  • 20.
    Pigmentation & Skinrejuvenation Before After (3 treat.)
  • 21.
    Combination of Peelingand IPL 3 treatments Before After
  • 22.
    Hands pigmentation onetreatment Before After
  • 23.
  • 24.
  • 25.
    F–AC Acne treatment  Faceacne treatment Technical information:  Energy: up to 22 j/cm.  Wavelength: 440 nm  Spot size: 1.6 cm2 Pulse duration:  Single: from 2 to 6 milliseconds  Double: from 1.5 to 3 milliseconds
  • 26.
    Acne treatment withF-AC Before After
  • 27.
    Acne treatment withIPL Before After
  • 28.
    R-sonic combined withIPL-SR under eye dark circle, 3 treatment performed once a week Before After (three week)
  • 29.