Wega, Nova and Stella are three Chilled Beams in the iQ Star® family. Together they offer virtually endless possibilities. Flexibility and energy efficiency are their characterizing features, both indispensable cornerstones for true Demand Controlled Ventilation.
The modern office is dynamic. With laptops and mobiles we can work where we want and carry out our tasks wherever it’s convenient. Astra and Stella are the new chilled beams from Fläkt Woods with the high quality required to easily adapt to new conditions. Success in business today also calls for flexibility to meet new demands, where rearrangements of people, walls and furniture should be realized with a minimum of effort.
Wega, Nova and Stella are designed for the modern offices, with equal focus on the importance of a productive working climate and the need to care for the environment. Wega is intended for flush-mounting installation whilst the Nova and the Stella beams are designed for exposed installation.
Attractive designs, smart functions, flexible construction and energy saving features make these chilled beams true iQ Stars®.
Wega, Nova i Stella to trzy belki chłodzące należące do rodziny iQ Star®. Ich możliwości są praktycznie nieskończone. Ich głównymi cechami charakterystycznymi są elastyczność w dostosowywaniu się do warunków projektowych oraz energooszczędność. Zalety wielce pożądane w przy realizacji wentylacji nadążnej.
Współczesne biura są dynamiczne. Mając do dyspozycji laptopy i telefony komórkowe, ludzie mogą pracować w dowolnym miejscu pomieszczenia. Stella to belka którą w łatwy sposób można zaadaptować do zmieniających się aranżacji biurowych.
Wega, Nova i Stella zostały zaprojektowane w odpowiedzi na potrzeby współczesnych biur, kładąc nacisk zarówno na wytwarzanie wysokiego komfortu pracy jak i na troskę o środowisko. Stella i Nova to belki wolnowiszące, natomiast Wega przeznaczona jest do montażu w płaszczyźnie stropu podwieszonego.
Atrakcyjny wygląd, przemyślane rozwiązania, elastyczna konstrukcja oraz energooszczędność czynią te belki chłodzące prawdziwymi gwiazdami linii iQ Stars®.
This document is a catalog from Sunbelt Rentals providing information on their climate control services including portable air conditioners, temporary heaters, and dehumidification equipment. The catalog lists specifications for various portable air conditioning units ranging from 1-5 tons, including details on cooling capacity, airflow, duct sizes, and electrical requirements. It also includes indexes and specifications for related equipment like dehumidifiers, fans, heaters and more.
This document summarizes Daikin's climate control solutions for the food and drink sector. It discusses how Daikin's heating, cooling, ventilation, and refrigeration systems can enhance customer and staff comfort while reducing energy costs and environmental impact. Key features highlighted include heat recovery technology that can save up to 60% on energy costs, self-cleaning units that improve hygiene and efficiency, and intelligent controls that optimize performance. Case studies demonstrate energy savings of up to 50% achieved for customers through integrated Daikin solutions.
Super inverter epcen08 114-catalogues_english (2)Henry Hollands
The document discusses Daikin's RZQ Super Inverter air conditioning system. It provides high energy efficiency through its use of inverter technology, DC fan motors, and refrigerants like R-410A. The system ensures maximum comfort with stable temperatures and sound levels as low as 43dB. It can connect to various indoor units and offers benefits like reusing existing piping and a operating range of -15°C to 50°C.
POWERPOINT PRESENTATION OF OUR BUSINESS DEVELOPMENT MODEL. SAMSUNG AIRCONDITI...Comrade Benson Osuya
Margaret Benson Nigeria Limited is an electrical engineering company specializing in power backup solutions like UPS systems, generators, and transformers. They introduce themselves and their team of professionals poised to serve customers through responsiveness and professionalism. They represent several global brands for reliable high-power UPS and precision AVR systems. They also represent generator brands from 10KVA to 2000KVA and are dealers for Samsung air conditioners and home appliances in Nigeria.
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology.
This document provides instructions and specifications for floor-mounted packaged air conditioners and ducted split air conditioners. It describes the main components of packaged and split AC units. It also explains the operating instructions and controller specifications for floor-mounted packaged ACs and ducted split ACs. Troubleshooting tips, technical specifications, schematics, and warranty information are included.
The document analyzes the best HVAC system for a retail store called Discount Dan's located in Biloxi, Mississippi. It recommends a heat pump, split duct, single zone, constant volume system because it has low initial and operating costs, requires minimal maintenance, and would not cause the store to close if one component failed. The system was chosen because heat pumps are efficient, do not require gas lines, and could provide both heating and cooling for the store given its mild climate. Three COP 3 heat pump units with air handlers would meet the heating and cooling needs of the 15,000 square foot store.
This document is a catalog from Sunbelt Rentals providing information on their climate control services including portable air conditioners, temporary heaters, and dehumidification equipment. The catalog lists specifications for various portable air conditioning units ranging from 1-5 tons, including details on cooling capacity, airflow, duct sizes, and electrical requirements. It also includes indexes and specifications for related equipment like dehumidifiers, fans, heaters and more.
This document summarizes Daikin's climate control solutions for the food and drink sector. It discusses how Daikin's heating, cooling, ventilation, and refrigeration systems can enhance customer and staff comfort while reducing energy costs and environmental impact. Key features highlighted include heat recovery technology that can save up to 60% on energy costs, self-cleaning units that improve hygiene and efficiency, and intelligent controls that optimize performance. Case studies demonstrate energy savings of up to 50% achieved for customers through integrated Daikin solutions.
Super inverter epcen08 114-catalogues_english (2)Henry Hollands
The document discusses Daikin's RZQ Super Inverter air conditioning system. It provides high energy efficiency through its use of inverter technology, DC fan motors, and refrigerants like R-410A. The system ensures maximum comfort with stable temperatures and sound levels as low as 43dB. It can connect to various indoor units and offers benefits like reusing existing piping and a operating range of -15°C to 50°C.
POWERPOINT PRESENTATION OF OUR BUSINESS DEVELOPMENT MODEL. SAMSUNG AIRCONDITI...Comrade Benson Osuya
Margaret Benson Nigeria Limited is an electrical engineering company specializing in power backup solutions like UPS systems, generators, and transformers. They introduce themselves and their team of professionals poised to serve customers through responsiveness and professionalism. They represent several global brands for reliable high-power UPS and precision AVR systems. They also represent generator brands from 10KVA to 2000KVA and are dealers for Samsung air conditioners and home appliances in Nigeria.
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology.
This document provides instructions and specifications for floor-mounted packaged air conditioners and ducted split air conditioners. It describes the main components of packaged and split AC units. It also explains the operating instructions and controller specifications for floor-mounted packaged ACs and ducted split ACs. Troubleshooting tips, technical specifications, schematics, and warranty information are included.
The document analyzes the best HVAC system for a retail store called Discount Dan's located in Biloxi, Mississippi. It recommends a heat pump, split duct, single zone, constant volume system because it has low initial and operating costs, requires minimal maintenance, and would not cause the store to close if one component failed. The system was chosen because heat pumps are efficient, do not require gas lines, and could provide both heating and cooling for the store given its mild climate. Three COP 3 heat pump units with air handlers would meet the heating and cooling needs of the 15,000 square foot store.
Active chilled beams are ceiling-mounted devices that provide cooling and ventilation to rooms. They work by drawing room air through a water coil to cool it before mixing it with primary air from the central system and distributing it into the room. Compared to conventional HVAC systems, active chilled beams reduce energy usage by transferring more of the cooling load to a more efficient water distribution system and circulating less air. They also improve occupant comfort through uniform temperatures and constant airflow. Active chilled beam systems are a popular "green" solution that lowers operating costs while meeting codes and standards.
Toshiba India Air Conditioners – Helping your world feel better.
Engineered with over 30 years of unmatched experience and advanced Japanese technology, the range of high-performance, energy-efficient Toshiba Air Conditioners is crafted with meticulous attention to research, customer preferences and innovation so as to meet the unique needs of the market.
Our offerings are focused at bringing our customers the ideal quality of air conditioning in their varied spaces. We also acknowledge our responsibility to safeguarding our environment, and constantly work to ensure that our products are sustainable, eco-friendly and pave the way towards enabling a greener, cleaner tomorrow.
Should you wish to connect with a Toshiba expert, feel free to Contact Us.
The document describes the key features and specifications of the Fresh-r in-the-wall ventilation unit. It separates the warm and cold sides with insulation and minimizes noise. It automatically adjusts airflow based on CO2 and humidity sensors to ventilate only as needed, saving up to 35% on energy. It uses a fine wire copper heat exchanger that efficiently transfers heat even below zero degrees and has a defrost program. It is balanced, Passive House certified, and has a WiFi connection option.
This document provides information about Climate Wizard, an air conditioning system that uses indirect evaporative cooling to provide cooling with greatly reduced energy consumption compared to traditional refrigerant-based systems. It then describes several example applications of Climate Wizard in both commercial and residential buildings, where it was used for stand-alone cooling, pre-cooling of outside air, and supplementary cooling to reduce loads on existing refrigerant cooling systems. Benefits highlighted include improved air quality, steady electrical demand, flexibility of design, lower installation costs, and reductions in energy use and operating costs.
Carrier's Inverter Ducted air conditioners provide energy efficient cooling and heating for residential applications. They allow for installation of indoor units in the ceiling with ducts distributing air to rooms. This provides a neat, unobtrusive installation and flexibility to condition a variety of room layouts. The inverter technology allows for precise temperature control and rapid attainment of target temperatures while reducing energy costs by up to 60% compared to non-inverter models. Carrier is a leading global provider of heating, ventilation and air conditioning solutions.
ActronAir's Classic ducted air conditioning system is engineered to withstand Australia's harsh conditions with an operating range of -10°C to 50°C. It provides reliable cooling and heating performance even at high outdoor temperatures when other systems shut down. The Classic features an integrated 8-zone touch pad controller and optional wireless control via smartphone. It is designed, manufactured, and serviced in Australia to ensure reliable support.
The document discusses various energy conservation measures that can be implemented in hotels to reduce energy costs and improve profitability. Some key measures mentioned include installing energy efficient machines, implementing auto controls and timers for HVAC and lighting systems, improving insulation and installing efficient windows, replacing incandescent bulbs with CFLs and LEDs, using occupancy sensors and natural light where possible, and educating guests and staff to turn off lights in unoccupied rooms. Taking these measures can help cut a hotel's energy costs by 10-15% and improve the bottom line.
The document discusses strategies to reduce energy consumption in laboratories by 50% through various HVAC, lighting, and equipment upgrades. It describes implementing centralized demand controlled ventilation to monitor air quality and reduce unoccupied air changes. Exhaust stack heights are increased and bypass air is reduced through analyzing minimum discharge velocities. Variable frequency drives are added to fans and pumps to allow modulation based on demand. Lighting is upgraded through replacing lamps and ballasts with more efficient options and adding occupancy sensors.
This document is Gree Electric Appliances, Inc.'s 2012 product catalogue for commercial air conditioners. It includes information about Gree such as being the world's largest air conditioner manufacturer, distributing products to over 100 countries, and being ranked among China's top 100 listed companies for 9 consecutive years. The catalogue then lists and provides specifications for Gree's various commercial air conditioning product lines, including unitary air conditioners, duct split units, rooftop packaged units, chillers, fan coil units, and control systems.
Reverse Cycle Air Conditioning BrochureInfinitiAir
This document provides information on ActronAir's product range of air conditioners, including:
- Wall split systems ranging from 2.6-8.2kW with features like variable capacity inverter technology, sleep mode, and follow me function.
- Ducted split systems available in standard cycling, variable capacity, and tri-capacity models up to 200kW with features like variable fan technology, variable air volume control, and Tru-Inverter technology.
- Package units in standard cycling, tri-capacity, and variable capacity models up to 170kW including the Hercules line with features like EC fan technology and state of the art controls.
- Vertical package units up to 85k
This document discusses different types of air conditioning systems and technologies. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also introduces new technologies like district cooling systems and chilled beam systems. District cooling systems involve a centralized plant that distributes chilled water through underground pipes to multiple buildings. Chilled beam systems use beams suspended from ceilings to circulate chilled water and cool rooms via convection. The document also outlines the basic refrigeration cycle used in air conditioning with its main components: compressor, condenser, expansion valve, and evaporator.
This document discusses different types of air conditioning systems and their components. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also discusses new technologies like district cooling systems and chilled beam systems. The cooling cycle/refrigeration cycle is explained through its key components: compressor, condenser, expansion valve, and evaporator. Requirements for coolants used in air conditioning systems are outlined.
This document discusses different types of air conditioning systems and their components. It introduces window units, split units, central air conditioning, and packaged units. It then covers the cooling cycle/refrigeration cycle involving the compressor, condenser, expansion valve, and evaporator. District cooling systems and chilled beam systems are also introduced as newer technologies. The coolant used in air conditioning systems must be non-toxic, non-explosive, non-corrosive, and have high electrical resistance while effectively lubricating components. Common coolants mentioned include R-22, R-12, and R-11.
This document discusses air conditioning systems. It begins with an introduction defining air conditioning and its goals of altering air properties like temperature and humidity for comfort or industrial processes. It then discusses the principles, types, and components of air conditioning systems. The main types are window units, split systems, centralised systems, and packaged systems. It also introduces new technologies like district cooling systems and chilled beam systems. Finally, it discusses the refrigeration cycle and common coolants used.
The document discusses cooling challenges for data centers and presents various cooling solutions. Specifically, it notes that cooling now accounts for 60-70% of data center energy costs. It then outlines challenges like increasing power densities and need for efficiency, availability, manageability, and serviceability. Various cooling architectures are presented, including room-based cooling, row-based cooling, and close-coupled cooling. Free cooling options using ambient air are also discussed.
Delta's CW/CWU chilled water cooling system provides precise temperature and humidity control for data centers. It is available in multiple configurations including downflow or upflow designs, integrated or underfloor fans, and standard or high heat exchanger densities. The system features highly efficient EC fans and evaporator coils, dual independent cooling circuits for flexibility and reliability, and advanced controls. Capacities range from 50 to 280 kW.
This document summarizes the features of new external air conditioning units:
- They have world-class energy efficiency due to improved compressors and propeller fans.
- Units can simultaneously turn indoor units on and off when connected to a single outdoor unit.
- Units are smaller, lighter, and have flexible pipe installation and wide temperature performance ranges.
Armcor Air Solutions are a leading Australian manufacturer of fresh air to air heat exchangers & heat recovery ventilation unit. Call us for our unique heat recovery systems.
https://armcor.com.au
The document discusses improving indoor air quality through proper ventilation. It states that increasing fresh air ventilation is the most practical and effective solution, as it dilutes indoor pollutant concentrations. However, simply increasing mechanical ventilation also increases energy costs for air conditioning. The document then discusses various energy recovery ventilator options that can increase ventilation rates while reducing energy costs, such as enthalpy wheels.
Airius - Destratification System Brochure V1.4Guy Bridges
The document summarizes Airius, a company that specializes in reducing energy usage in buildings through destratification. Airius manufactures fans that evenly circulate air within a space to eliminate hot and cold spots, reducing temperature differences between the floor and ceiling to 0-2°C. This maximizes the efficiency of heating and cooling systems, saving customers 20-50% on energy bills. The document provides information on Airius' product range, technical specifications, applications, and independent testing that validate the energy savings achieved through destratification.
Instrukcja obsługi programu doboru systemów różnicowania ciśnień (inaczej napowietrzania, ang.: pressurization systems) - jednego z elementów aktywnej ochrony pożarowej i certyfikowanego systemu z zakresu bezpieczeństwa pożarowego (systemy kontroli rozprzestrzeniania się ognia i dymu).
Najbardziej zaawansowany na świecie program doboru pozwalający na rysowanie poszczególnych trzonów, wyróżnianie kondygnacji, określanie ilości i wielkości przedsionków, klatek schodowych, korytarzy, szybów windowych i drzwi oraz ich wzajemnego położenia i relacji. Program wylicza kompletny system na podstawie wybranego scenariusza, przygotowuje dokumentację w plikach dwg oraz pozwala zarządzać wprowadzonymi projektami.
Niniejsza instrukcja wprowadza w podstawy intuicyjnego interfejcu użytkownika.
więcej: pressair.pl
Katalog zawiera dane techniczne systemów różnicowania ciśnień (napowietrzania klatek schodowych) SMIA i SMPA.
Poszczególne strony wyjaśniają zasadę działania systemu, prezentują poszczególne elementy systemu wraz z rysunkami technicznymi, wykresami i akcesoriami. System zapobiegania rozprzestrzeniania się dymu i ognia przez różnicowanie ciśnień SMIA / SMPA może być stosowany zarówno do klatek schodowych, szybów windowych i przedsionków, jak również do ochrony skomplikowanych układów architektonicznych zawierających przedsionki, klatki schodowe, korytarze i szyby windowe w różnych konfiguracjach i zróżnicowanej architekturze. Zestaw SMIA umożliwia dodatkowo oddymianie obiektu po zakończeniu akcji gaśniczej.
More Related Content
Similar to Belka chłodząca / Chilled beam IQ Star Stella 2012
Active chilled beams are ceiling-mounted devices that provide cooling and ventilation to rooms. They work by drawing room air through a water coil to cool it before mixing it with primary air from the central system and distributing it into the room. Compared to conventional HVAC systems, active chilled beams reduce energy usage by transferring more of the cooling load to a more efficient water distribution system and circulating less air. They also improve occupant comfort through uniform temperatures and constant airflow. Active chilled beam systems are a popular "green" solution that lowers operating costs while meeting codes and standards.
Toshiba India Air Conditioners – Helping your world feel better.
Engineered with over 30 years of unmatched experience and advanced Japanese technology, the range of high-performance, energy-efficient Toshiba Air Conditioners is crafted with meticulous attention to research, customer preferences and innovation so as to meet the unique needs of the market.
Our offerings are focused at bringing our customers the ideal quality of air conditioning in their varied spaces. We also acknowledge our responsibility to safeguarding our environment, and constantly work to ensure that our products are sustainable, eco-friendly and pave the way towards enabling a greener, cleaner tomorrow.
Should you wish to connect with a Toshiba expert, feel free to Contact Us.
The document describes the key features and specifications of the Fresh-r in-the-wall ventilation unit. It separates the warm and cold sides with insulation and minimizes noise. It automatically adjusts airflow based on CO2 and humidity sensors to ventilate only as needed, saving up to 35% on energy. It uses a fine wire copper heat exchanger that efficiently transfers heat even below zero degrees and has a defrost program. It is balanced, Passive House certified, and has a WiFi connection option.
This document provides information about Climate Wizard, an air conditioning system that uses indirect evaporative cooling to provide cooling with greatly reduced energy consumption compared to traditional refrigerant-based systems. It then describes several example applications of Climate Wizard in both commercial and residential buildings, where it was used for stand-alone cooling, pre-cooling of outside air, and supplementary cooling to reduce loads on existing refrigerant cooling systems. Benefits highlighted include improved air quality, steady electrical demand, flexibility of design, lower installation costs, and reductions in energy use and operating costs.
Carrier's Inverter Ducted air conditioners provide energy efficient cooling and heating for residential applications. They allow for installation of indoor units in the ceiling with ducts distributing air to rooms. This provides a neat, unobtrusive installation and flexibility to condition a variety of room layouts. The inverter technology allows for precise temperature control and rapid attainment of target temperatures while reducing energy costs by up to 60% compared to non-inverter models. Carrier is a leading global provider of heating, ventilation and air conditioning solutions.
ActronAir's Classic ducted air conditioning system is engineered to withstand Australia's harsh conditions with an operating range of -10°C to 50°C. It provides reliable cooling and heating performance even at high outdoor temperatures when other systems shut down. The Classic features an integrated 8-zone touch pad controller and optional wireless control via smartphone. It is designed, manufactured, and serviced in Australia to ensure reliable support.
The document discusses various energy conservation measures that can be implemented in hotels to reduce energy costs and improve profitability. Some key measures mentioned include installing energy efficient machines, implementing auto controls and timers for HVAC and lighting systems, improving insulation and installing efficient windows, replacing incandescent bulbs with CFLs and LEDs, using occupancy sensors and natural light where possible, and educating guests and staff to turn off lights in unoccupied rooms. Taking these measures can help cut a hotel's energy costs by 10-15% and improve the bottom line.
The document discusses strategies to reduce energy consumption in laboratories by 50% through various HVAC, lighting, and equipment upgrades. It describes implementing centralized demand controlled ventilation to monitor air quality and reduce unoccupied air changes. Exhaust stack heights are increased and bypass air is reduced through analyzing minimum discharge velocities. Variable frequency drives are added to fans and pumps to allow modulation based on demand. Lighting is upgraded through replacing lamps and ballasts with more efficient options and adding occupancy sensors.
This document is Gree Electric Appliances, Inc.'s 2012 product catalogue for commercial air conditioners. It includes information about Gree such as being the world's largest air conditioner manufacturer, distributing products to over 100 countries, and being ranked among China's top 100 listed companies for 9 consecutive years. The catalogue then lists and provides specifications for Gree's various commercial air conditioning product lines, including unitary air conditioners, duct split units, rooftop packaged units, chillers, fan coil units, and control systems.
Reverse Cycle Air Conditioning BrochureInfinitiAir
This document provides information on ActronAir's product range of air conditioners, including:
- Wall split systems ranging from 2.6-8.2kW with features like variable capacity inverter technology, sleep mode, and follow me function.
- Ducted split systems available in standard cycling, variable capacity, and tri-capacity models up to 200kW with features like variable fan technology, variable air volume control, and Tru-Inverter technology.
- Package units in standard cycling, tri-capacity, and variable capacity models up to 170kW including the Hercules line with features like EC fan technology and state of the art controls.
- Vertical package units up to 85k
This document discusses different types of air conditioning systems and technologies. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also introduces new technologies like district cooling systems and chilled beam systems. District cooling systems involve a centralized plant that distributes chilled water through underground pipes to multiple buildings. Chilled beam systems use beams suspended from ceilings to circulate chilled water and cool rooms via convection. The document also outlines the basic refrigeration cycle used in air conditioning with its main components: compressor, condenser, expansion valve, and evaporator.
This document discusses different types of air conditioning systems and their components. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also discusses new technologies like district cooling systems and chilled beam systems. The cooling cycle/refrigeration cycle is explained through its key components: compressor, condenser, expansion valve, and evaporator. Requirements for coolants used in air conditioning systems are outlined.
This document discusses different types of air conditioning systems and their components. It introduces window units, split units, central air conditioning, and packaged units. It then covers the cooling cycle/refrigeration cycle involving the compressor, condenser, expansion valve, and evaporator. District cooling systems and chilled beam systems are also introduced as newer technologies. The coolant used in air conditioning systems must be non-toxic, non-explosive, non-corrosive, and have high electrical resistance while effectively lubricating components. Common coolants mentioned include R-22, R-12, and R-11.
This document discusses air conditioning systems. It begins with an introduction defining air conditioning and its goals of altering air properties like temperature and humidity for comfort or industrial processes. It then discusses the principles, types, and components of air conditioning systems. The main types are window units, split systems, centralised systems, and packaged systems. It also introduces new technologies like district cooling systems and chilled beam systems. Finally, it discusses the refrigeration cycle and common coolants used.
The document discusses cooling challenges for data centers and presents various cooling solutions. Specifically, it notes that cooling now accounts for 60-70% of data center energy costs. It then outlines challenges like increasing power densities and need for efficiency, availability, manageability, and serviceability. Various cooling architectures are presented, including room-based cooling, row-based cooling, and close-coupled cooling. Free cooling options using ambient air are also discussed.
Delta's CW/CWU chilled water cooling system provides precise temperature and humidity control for data centers. It is available in multiple configurations including downflow or upflow designs, integrated or underfloor fans, and standard or high heat exchanger densities. The system features highly efficient EC fans and evaporator coils, dual independent cooling circuits for flexibility and reliability, and advanced controls. Capacities range from 50 to 280 kW.
This document summarizes the features of new external air conditioning units:
- They have world-class energy efficiency due to improved compressors and propeller fans.
- Units can simultaneously turn indoor units on and off when connected to a single outdoor unit.
- Units are smaller, lighter, and have flexible pipe installation and wide temperature performance ranges.
Armcor Air Solutions are a leading Australian manufacturer of fresh air to air heat exchangers & heat recovery ventilation unit. Call us for our unique heat recovery systems.
https://armcor.com.au
The document discusses improving indoor air quality through proper ventilation. It states that increasing fresh air ventilation is the most practical and effective solution, as it dilutes indoor pollutant concentrations. However, simply increasing mechanical ventilation also increases energy costs for air conditioning. The document then discusses various energy recovery ventilator options that can increase ventilation rates while reducing energy costs, such as enthalpy wheels.
Airius - Destratification System Brochure V1.4Guy Bridges
The document summarizes Airius, a company that specializes in reducing energy usage in buildings through destratification. Airius manufactures fans that evenly circulate air within a space to eliminate hot and cold spots, reducing temperature differences between the floor and ceiling to 0-2°C. This maximizes the efficiency of heating and cooling systems, saving customers 20-50% on energy bills. The document provides information on Airius' product range, technical specifications, applications, and independent testing that validate the energy savings achieved through destratification.
Similar to Belka chłodząca / Chilled beam IQ Star Stella 2012 (20)
Instrukcja obsługi programu doboru systemów różnicowania ciśnień (inaczej napowietrzania, ang.: pressurization systems) - jednego z elementów aktywnej ochrony pożarowej i certyfikowanego systemu z zakresu bezpieczeństwa pożarowego (systemy kontroli rozprzestrzeniania się ognia i dymu).
Najbardziej zaawansowany na świecie program doboru pozwalający na rysowanie poszczególnych trzonów, wyróżnianie kondygnacji, określanie ilości i wielkości przedsionków, klatek schodowych, korytarzy, szybów windowych i drzwi oraz ich wzajemnego położenia i relacji. Program wylicza kompletny system na podstawie wybranego scenariusza, przygotowuje dokumentację w plikach dwg oraz pozwala zarządzać wprowadzonymi projektami.
Niniejsza instrukcja wprowadza w podstawy intuicyjnego interfejcu użytkownika.
więcej: pressair.pl
Katalog zawiera dane techniczne systemów różnicowania ciśnień (napowietrzania klatek schodowych) SMIA i SMPA.
Poszczególne strony wyjaśniają zasadę działania systemu, prezentują poszczególne elementy systemu wraz z rysunkami technicznymi, wykresami i akcesoriami. System zapobiegania rozprzestrzeniania się dymu i ognia przez różnicowanie ciśnień SMIA / SMPA może być stosowany zarówno do klatek schodowych, szybów windowych i przedsionków, jak również do ochrony skomplikowanych układów architektonicznych zawierających przedsionki, klatki schodowe, korytarze i szyby windowe w różnych konfiguracjach i zróżnicowanej architekturze. Zestaw SMIA umożliwia dodatkowo oddymianie obiektu po zakończeniu akcji gaśniczej.
IPSUM Optimization System - ogromny krok naprzód dla komfortu i oszczędności energii
Fläkt Woods długo pracuje z systemami do sterowania wentylacją „na żądanie” i wykorzystał wieloletnie doświadczenie, aby zaprojektować system optymalizacji IPSUM. System IPSUM reguluje ilość powietrza świeżego w pomieszczeniach w zależności od rzeczywistych potrzeb. Oznacza to, że wysoka jakość powietrza w pomieszczeniach może być osiągnięta w tym samym czasie, a zużycie energii jest ograniczone do minimum.
IPSUM optymalizuje ciśnienie i nastawy temperatury w centrali wentylacyjnej do osiągnięcia najniższych możliwych kosztów operacyjnych. Oprócz produktów zależnych od składników niezbędnych dla systemu VAV, IPSUM™ System składa się z trzech elementów:
- IPSUM™ System Optimizer - optymalizuje dane operacyjne dla centrali wentylacyjnej
- IPSUM™ System Router - łączy pomieszczenia, kondygnacje i strefy.
- IPSUM™ Connection Unit – służy do podłączenie elementów do systemu, na przykład: regulatorów pomieszczeniowych i siłowników systemu VAV.
Trzy unikalne systemy przygotowania powietrza dla celów wentylacji i klimatyzacji przeznaczone do wbudowania w centrale wentlyacyjne Flakt Woods:
Combi Cooler
Używany do chłodzenia powietrza jaki wody dla belek chłodzących. Może również pracować chłodząc wodę dla belek i ogrzewając powietrze ciepłem z zewnętrznego źródła. Temperatura zasilania to zwykle 15-16 °C. Dla Combi Cooler, ta temperature to 18 °C, co daje oszczędności energii. Unikamy również kondensacji.
Twin Wheel
Kompaktowy system składający się z dwóch obrotowych wymienników ciepła i zintegrowanej automatyki. Nadaje się do projektów, w których istnieje potrzeba osuszania i ogrzewania powietrza, np. belki chłodzące przy dużej wilgotności powietrza. Automatyka optymalizuje chłodzenie i odzysk ciepła, a tym samym zmniejsza ilość energii potrzebną do dodatkowego chłodzenia i ogrzewania w tym samym czasie. Eliminowane jest również ryzyko wykraplania.
Econet®
Cieczowy system odzysku ciepła z wbudowana pompą z falownikiem oraz zintegrowaną automatyką w celu optymalizacji pracy wymiennika. Wyjątkowa konstrukcja pozawala na wykorzystanie do odzysku ciepła, chłodzenia i ogrzewania. Poza oszczędnością energii system ten eliminuje ryzyko zanieczyszczenia.
Three unique energy efficient systems for preparing a comfort air inside Flakt Woods air handling units:
Combi Cooler
The Combi Cooler cools water which is subsequently used to cool supply air and a chilled beam circuit. It can also produce cold water for the chilled beam circuit while simultaneously heating the supply air using heat from an external system. The supply air temperature is 15-16 °C in traditional systems. With the Combi Cooler, the temperature is 18 °C, offering significant energy savings. Energy consuming condensation is also avoided.
Twin Wheel
Packaged system consisting of two rotary heat exchangers and integrated controls. Suitable for applications where there is a need for dehumidification and reheat of the air, e.g. chilled beam system in climates with high humidity. The control sequence optimises the cooling and heating recovery and thereby reduces need for additional cooling and heating energy at the same time as the risk for condensation is eliminated.
Econet®
Liquid coupled (coil) energy recovery system with a prefabricated pump-unit with frequency inverter and integrated controls for continuous optimisation of the recovery efficiency. Unique system design allows usage of waste heat, district heating and district cooling. Apart from energy savings, this system also eliminates the risk for contamination.
Opatentowany przez firmę Fläkt Woods system Combi Cooler oferuje zupełnie nowe możliwości w trakcie planowania i opracowywania specyfikacji systemów chłodzenia. Moduł Combi Cooler może być scalany z centrala wentylacyjną i montowany w niej bezpośrednio. Nadaje się zwłaszcza do wykorzystywania wspólnie z systemami belek chłodzących.
Moduł Combi Cooler pozwala zaoszczędzić do 40% energii.
W systemach wykorzystujących moduł Combi Cooler można obniżyć poziom zużycia energii do takiego stopnia, że moc chłodnicza 100 kW może być uzyskiwana z 21,5 kW, zamiast z 35 kW.
An integrated system comprising of an ultra-compact AHU installation precisely matched to the requirements of room mounted Chilled Beams, selected from a comprehensive range of styles and sizes. Combi Cooler technology removes the need for expensive and space consuming external condenser units, whilst integrated Room Controllers monitor temperature and provide an adjustable set point and seamless connection to the BMS.
The document provides technical specifications for Flexicool chilled beams. It includes details on various beam models, functions like cooling, heating, lighting, and installation methods. The models covered are Combi Cooler, Twin Wheel, suspended ceiling beams, passive chilled beams, and beams with variable airflow. Technical data, dimensions, and performance characteristics are provided for each type.
In his public lecture, Christian Timmerer provides insights into the fascinating history of video streaming, starting from its humble beginnings before YouTube to the groundbreaking technologies that now dominate platforms like Netflix and ORF ON. Timmerer also presents provocative contributions of his own that have significantly influenced the industry. He concludes by looking at future challenges and invites the audience to join in a discussion.
Generative AI Deep Dive: Advancing from Proof of Concept to ProductionAggregage
Join Maher Hanafi, VP of Engineering at Betterworks, in this new session where he'll share a practical framework to transform Gen AI prototypes into impactful products! He'll delve into the complexities of data collection and management, model selection and optimization, and ensuring security, scalability, and responsible use.
Removing Uninteresting Bytes in Software FuzzingAftab Hussain
Imagine a world where software fuzzing, the process of mutating bytes in test seeds to uncover hidden and erroneous program behaviors, becomes faster and more effective. A lot depends on the initial seeds, which can significantly dictate the trajectory of a fuzzing campaign, particularly in terms of how long it takes to uncover interesting behaviour in your code. We introduce DIAR, a technique designed to speedup fuzzing campaigns by pinpointing and eliminating those uninteresting bytes in the seeds. Picture this: instead of wasting valuable resources on meaningless mutations in large, bloated seeds, DIAR removes the unnecessary bytes, streamlining the entire process.
In this work, we equipped AFL, a popular fuzzer, with DIAR and examined two critical Linux libraries -- Libxml's xmllint, a tool for parsing xml documents, and Binutil's readelf, an essential debugging and security analysis command-line tool used to display detailed information about ELF (Executable and Linkable Format). Our preliminary results show that AFL+DIAR does not only discover new paths more quickly but also achieves higher coverage overall. This work thus showcases how starting with lean and optimized seeds can lead to faster, more comprehensive fuzzing campaigns -- and DIAR helps you find such seeds.
- These are slides of the talk given at IEEE International Conference on Software Testing Verification and Validation Workshop, ICSTW 2022.
Enchancing adoption of Open Source Libraries. A case study on Albumentations.AIVladimir Iglovikov, Ph.D.
Presented by Vladimir Iglovikov:
- https://www.linkedin.com/in/iglovikov/
- https://x.com/viglovikov
- https://www.instagram.com/ternaus/
This presentation delves into the journey of Albumentations.ai, a highly successful open-source library for data augmentation.
Created out of a necessity for superior performance in Kaggle competitions, Albumentations has grown to become a widely used tool among data scientists and machine learning practitioners.
This case study covers various aspects, including:
People: The contributors and community that have supported Albumentations.
Metrics: The success indicators such as downloads, daily active users, GitHub stars, and financial contributions.
Challenges: The hurdles in monetizing open-source projects and measuring user engagement.
Development Practices: Best practices for creating, maintaining, and scaling open-source libraries, including code hygiene, CI/CD, and fast iteration.
Community Building: Strategies for making adoption easy, iterating quickly, and fostering a vibrant, engaged community.
Marketing: Both online and offline marketing tactics, focusing on real, impactful interactions and collaborations.
Mental Health: Maintaining balance and not feeling pressured by user demands.
Key insights include the importance of automation, making the adoption process seamless, and leveraging offline interactions for marketing. The presentation also emphasizes the need for continuous small improvements and building a friendly, inclusive community that contributes to the project's growth.
Vladimir Iglovikov brings his extensive experience as a Kaggle Grandmaster, ex-Staff ML Engineer at Lyft, sharing valuable lessons and practical advice for anyone looking to enhance the adoption of their open-source projects.
Explore more about Albumentations and join the community at:
GitHub: https://github.com/albumentations-team/albumentations
Website: https://albumentations.ai/
LinkedIn: https://www.linkedin.com/company/100504475
Twitter: https://x.com/albumentations
Unlocking Productivity: Leveraging the Potential of Copilot in Microsoft 365, a presentation by Christoforos Vlachos, Senior Solutions Manager – Modern Workplace, Uni Systems
GraphSummit Singapore | The Art of the Possible with Graph - Q2 2024Neo4j
Neha Bajwa, Vice President of Product Marketing, Neo4j
Join us as we explore breakthrough innovations enabled by interconnected data and AI. Discover firsthand how organizations use relationships in data to uncover contextual insights and solve our most pressing challenges – from optimizing supply chains, detecting fraud, and improving customer experiences to accelerating drug discoveries.
Why You Should Replace Windows 11 with Nitrux Linux 3.5.0 for enhanced perfor...SOFTTECHHUB
The choice of an operating system plays a pivotal role in shaping our computing experience. For decades, Microsoft's Windows has dominated the market, offering a familiar and widely adopted platform for personal and professional use. However, as technological advancements continue to push the boundaries of innovation, alternative operating systems have emerged, challenging the status quo and offering users a fresh perspective on computing.
One such alternative that has garnered significant attention and acclaim is Nitrux Linux 3.5.0, a sleek, powerful, and user-friendly Linux distribution that promises to redefine the way we interact with our devices. With its focus on performance, security, and customization, Nitrux Linux presents a compelling case for those seeking to break free from the constraints of proprietary software and embrace the freedom and flexibility of open-source computing.
Encryption in Microsoft 365 - ExpertsLive Netherlands 2024Albert Hoitingh
In this session I delve into the encryption technology used in Microsoft 365 and Microsoft Purview. Including the concepts of Customer Key and Double Key Encryption.
Full-RAG: A modern architecture for hyper-personalizationZilliz
Mike Del Balso, CEO & Co-Founder at Tecton, presents "Full RAG," a novel approach to AI recommendation systems, aiming to push beyond the limitations of traditional models through a deep integration of contextual insights and real-time data, leveraging the Retrieval-Augmented Generation architecture. This talk will outline Full RAG's potential to significantly enhance personalization, address engineering challenges such as data management and model training, and introduce data enrichment with reranking as a key solution. Attendees will gain crucial insights into the importance of hyperpersonalization in AI, the capabilities of Full RAG for advanced personalization, and strategies for managing complex data integrations for deploying cutting-edge AI solutions.
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...Neo4j
Leonard Jayamohan, Partner & Generative AI Lead, Deloitte
This keynote will reveal how Deloitte leverages Neo4j’s graph power for groundbreaking digital twin solutions, achieving a staggering 100x performance boost. Discover the essential role knowledge graphs play in successful generative AI implementations. Plus, get an exclusive look at an innovative Neo4j + Generative AI solution Deloitte is developing in-house.
TrustArc Webinar - 2024 Global Privacy SurveyTrustArc
How does your privacy program stack up against your peers? What challenges are privacy teams tackling and prioritizing in 2024?
In the fifth annual Global Privacy Benchmarks Survey, we asked over 1,800 global privacy professionals and business executives to share their perspectives on the current state of privacy inside and outside of their organizations. This year’s report focused on emerging areas of importance for privacy and compliance professionals, including considerations and implications of Artificial Intelligence (AI) technologies, building brand trust, and different approaches for achieving higher privacy competence scores.
See how organizational priorities and strategic approaches to data security and privacy are evolving around the globe.
This webinar will review:
- The top 10 privacy insights from the fifth annual Global Privacy Benchmarks Survey
- The top challenges for privacy leaders, practitioners, and organizations in 2024
- Key themes to consider in developing and maintaining your privacy program
20 Comprehensive Checklist of Designing and Developing a WebsitePixlogix Infotech
Dive into the world of Website Designing and Developing with Pixlogix! Looking to create a stunning online presence? Look no further! Our comprehensive checklist covers everything you need to know to craft a website that stands out. From user-friendly design to seamless functionality, we've got you covered. Don't miss out on this invaluable resource! Check out our checklist now at Pixlogix and start your journey towards a captivating online presence today.
Building RAG with self-deployed Milvus vector database and Snowpark Container...Zilliz
This talk will give hands-on advice on building RAG applications with an open-source Milvus database deployed as a docker container. We will also introduce the integration of Milvus with Snowpark Container Services.
2. tella is our free-hanging multi-service Chilled Beam in the new iQ Star family.
It is characterized by modularity, flexibility, sustainability and energy efficiency.
Stella is developed specifically for the high demands of the modern, dynamic
office where an attractive design is equally important to cutting-edge energy
saving features. Thanks to pioneering nozzle technology and smart controls,
the air flow is always sufficient and adapted to just-in-time need. Stella’s
modularity and the Flow Pattern Control and Energy Control functions allow flexibility in
the office layout. Good indoor air quality is possible despite organizational changes and
renovations without the need to change the installation.
Boost, Normal or Energy Saving mode
The traditional office with rooms and cubicles that are occupied from 9 to 5 will soon be
a distant memory. Most office space is hardly ever used, or sometimes it is overused.
Stella’s smart control panel with Normal, Energy Saving and Boost modes enables easy
adjustment of the air flow. This means that whether an office or meeting room is empty or
crowded, the Stella beam provides sufficient air flow. Not only does it save a lot of energy
when the room is not in use, it also keeps the employees spry and alert. A good reason to
have high indoor air quality.
Flexible, comfortable and energy
efficient climate for the modern office
S
3. Flow Pattern Control
The unique Flow Pattern Control
(FPC) can direct the airflow up to 45
degrees through integrated vanes.
Different directions can be set at
sections of 300 mm in the beam.
Accessories
Flexibility is increased by the
numerous accessories available
for iQ Star. Not only is Stella
available with any equipment you
need, you also have the oppor-
tunity to customize its design.
Energy control
The new flexible nozzle
arrangement guarantees
high indoor air quality and
energy efficiency. A quiet
solution even when high
air flow is needed.
Stella
4. Increased productivity
and low energy costs
Demand Controlled
Ventilation
Today, most people spend over 90 per-
cent of their time indoors e.g. at home,
in schools, at hospitals and offices.
Breathing fresh indoor air is vital for
our health, performance and well-being.
Demand controlled ventilation provides desired ventila-
tion based on the actual occupancy of the room. It
increases indoor air quality and saves energy normally
wasted in ventilating unoccupied spaces. This can be
applied to areas where there are frequent changes in
occupancy, such as conference rooms, board rooms,
cafeterias etc. Field experience indicates that actual oc-
cupancy levels are at least 25% lower and perhaps as
much as 60% lower. In normal office building the offices
are not occupied more than 60% of the time during a
normal working day. This means that demand controlled
ventilation can reduce ventilation as well as heating and
cooling loads by 10%–30%.
ENERGYCONSUMPTION
DEMAND
CONTROLLED
VENTILATION
5. The STRA-14 room controller is
specifically developed for Stella.
It is pre-programmed for chilled beam
applications and contains a wide range
of control functions including a unique
three step air flow control for flexibility,
comfort and energy efficiency.
The user-friendly display enables
fast and easy access for change of
set-points and control parameters.
For optional integration with building
management systems, STRA-14 has
Modbus communication as standard.
For rooms with variations in occupancy,
the optional occupancy sensor
enables a control strategy where the
controller is in Energy saving mode
(reduced air flow and increased neutral
zone for heating and cooling) when
the room is unoccupied and thereby
energy is saved. When the occupancy
sensor is activated by presence in the
room, the controller shifts to Normal
mode and controls airflow, heating
and cooling for comfort.
Experience has shown that the level
of CO2
in a room is a reliable indicator
of the indoor air quality, and is there-
fore used as the determing parameter
in the integrated Energy Control in
Stella. A high level of CO2
in a room
indicates that the ventilation rate is
insufficient to obtain an adequate
indoor quality.
This is a common situation in
rooms with large variations or peaks
in load, therefore STRA-14 can be
equipped with an optional CO2
-sensor
and thereby offer a control function
where the controller shifts to Boost
mode if the level of CO2
exceeds
the set point value, in this mode the
integrated Energy Control opens and
the air flow is increased until the level
of CO2
has decreased to the lower set
point value.
The built in operator button on STRA-
14 can also be used to activate the
bypass mode, after 60 minute the
controller then change back to its
preset operating mode.
User-friendly controller for optimal performance
1 2 3 4 5 6 1 65432
1 2 3 4 5 6
1 2 3 4 5 6 1 65432
1 2 3 4 5 6
1 2 3 4 5 6 1 432
1 4 5 6
1 2 3 4 5 6 1 432
1
1 32
432
1
1
Pioneering nozzles
Stella always provides sufficient air
flow, whether the room is empty or
crowded. Choose Normal, Energy
Saving or Boost mode on the room
controller. The new flexible nozzle
arrangement guarantees high indoor
air quality and energy efficiency.
A quiet solution even when high
air flow is needed.
6. Flexible solutions for
your changing needs
The modern office is dynamic. Fast decisions in
organisational changes call for a modern ventilation
system that is easy to adjust to the rearrange-
ment of people, walls and furniture and to meet
the just in time need. Flexibility is an important
factor for optimized indoor air quality.
Open plan office – 100%
Airflow 2,0 dm3
/s, m2
Cooling 23°C/25°C
Heating 21°C/21°C
Heat loads Mo–Fr 08–16
– people 0,11 people/m2
– lighting 12,5 W/m2
– equipment 16,0 W/m2
Office energy saving mode – 0%
Airflow 0,6 dm3
/s, m2
Cooling 24°C/26°C
Heating 20°C/20°C
Heat loads
– people 0 people/m2
– lighting 0 W/m2
– equipment 0 W/m2
Office – 100%
Airflow 2 dm3
/s, m2
Cooling 23°C/25°C
Heating 21°C/21°C
Heat loads Mo–Fr 08–16
– people 0,1 people/m2
– lighting 12,5 W/m2
– equipment 15,0 W/m2
Open plan office – 50%
Airflow 1,0 dm3
/s, m2
Cooling 23°C/25°C
Heating 21°C/21°C
Heat loads Mo–Fr 08–16
– people 0,055 people/m2
– lighting 12,5 W/m2
– equipment 8,0 W/m2
7. IQ Chilled Beams
with FPC function
Highest possible efficiency can
be maintained by adjusting the
comfort control and air vanes!
A combination of different
angles on one side is possible.
When increased air flow is
required, the flow pattern
can be adapted to maintain
optimal comfort in the room!
Flexibility in the office layout
Good indoor air quality is possible despite
organizational changes and renovations
without the need to change the installation.
Thanks to the functions Energy Control
and Flow Pattern Control, the air flow can
be rearranged to fit a new layout of a room.
Before
(old office configuration)
After
(new office configuration)
8. Design your own customized Stella
Design is important for the indoor environment. Stella
has a modern standard design, but offers the opportunity
to create a unique design depending on room use and
personal taste. Design and colour - you decide!
9.
10. The diagram shows the
approximate cooling effect
Ptot
in W with water flow qw
= 0.1 l/s, temperature differ-
ence between room air and
supply air ∆t = 8°C, pressure
drop 70 Pa on the air side
and max. sound pressure
level LA10
= 30 dB(A).
iQ Star Stella chilled beam – cross-section
Quick selection iQ Star Stella chilled beam
1002 overall width
338beamheight
115
Beam supply air slot
with FPC
Plain face central panel
for sprinkler and other services
Primary air beam duct entry spigot 125
22 supply and return
to rear beams (optional)
Heating
Return
Cooling
Return
Cooling
Supply
Heating
Supply
Sprinkler header and pipework fitted by others
Motorized Energy ControlM8 rod for fastening
Removable sideplate
for access during
installation/maintenance
Removable perforated plate
for access during maintenance
Plain faced infill panel between
light louvres for services
Luminaire with up- and down light
Area free from
obstructions
for up lighting
0
0 10 20 30 40
40
50
60
70
80
90
50
120
110
100800
600
400
200
1000
Cooling effect, W/m Static pressure, Pa
1100 6 65
5
32
2
1
1
4
4
3
Cooling effect/active m for position 1 - 6, W/m
Staticpressure,Pa
Supply air flow/active m for position 1 - 6, l/s, m
11. iQ Star Stella chilled beam
D74
541
A
B
CC
79 44
Ø125 Ø125
cw out Ø15
hw out Ø15
cw in Ø15
hw in Ø15
hw in Ø22 hw out Ø22
cw in Ø22 cw out Ø22
bbb = 101,111
bbb = 000
722
260
1002
226
264
338
156
648
267
309
79
cw out Ø15
ww out Ø15
cw in Ø15
ww in Ø15
1002
226
156
Dimensions
Size A B C D
180 1798 1546 – 116
240 2398 2138 1069 124
300 2998 2730 1365 132
Weight
Weight per meter of chilled beam kg/m
Beam dry weight 42.0
Beam water filled, cooling 43.4
Beam water filled, cooling and heating 43.8
12. We Bring Air to Life
Fläkt Woods Group SA
18, avenue Louis Casaï, CH-1209 Geneva, Switzerland
Tel. +41 22 309 3800
email info@flaktwoods.com www.flaktwoods.com
See global website for international
sales offices www.flaktwoods.com
FWG-StellaTechnicalSalesBrochure-GB-10-8895CCJKommunikation
Fläkt Woods is a global
leader in air management.
We specialise in the design
and manufacture of a wide
range of air climate and air
movement solutions. And
our collective experience
is unrivalled.
Our constant aim is to
provide systems that
precisely deliver required
function and performance,
as well as maximise
energy efficiency.
Air Handling Units (AHUs)
Modular, compact and small AHU
units. Designed to ensure optimisa-
tion of indoor air quality, operational
performance and service life.
Air Terminal Devices and Ducts
Supply and exhaust diffusers and
valves for installation on walls, ceiling
or floor are all included in our large
range and fit all types of applications.
Chilled Beams
Active induction beams for ventilation,
cooling and heating, and passive
convection beams for cooling. For
suspended or flush-mounted ceiling
installation – and multi-service config-
uration. With unique Comfort Control
and Flow Pattern Control features.
Residential ventilation
A complete range of products for
residential ventilation. Consists of
ventilation units, exhaust air fans and
cooker hoods designed to optimise
indoor comfort and save energy.
Energy recovery
Dessicant-based product and systems
that recover energy, increase ventilation
and control humidity.
Fans
Advanced axial, centrifugal and
boxed fans for general and specialist
applications. Comprehensive range
including high temperature and ATEX
compliant options. Engineered for
energy efficiency and minimised life
cycle cost.
Chillers
Air-cooled and water-cooled chillers
with cooling capacity up to 1800kW.
Designed to minimise annual energy
consumption in all types of buildings.
Controls and drives
Variable speed drives and control
systems, all tested to ensure total
compatibility with our products.
Specialist team can advise on energy
saving and overall system integration.
Acoustical Products
A complete line of sound attenuating
products, including rectangular and
round silencers, Media Free silencers,
custom silencers and acoustic
enclosure panels.
Solutions for all your air climate and air movement needs
Fläkt Woods is providing solutions for ventilation and air climate for buildings as
well as fan solutions for Industry and Infrastructure.