SlideShare a Scribd company logo
1 of 1
IMPROVED VOLTAGE-VECTOR SEQUENCES ON DEAD-BEAT
PREDICTIVE DIRECT POWER CONTROL OF REVERSIBLE THREEPHASE GRID-CONNECTED VOLTAGE-SOURCE CONVERTERS
ABSTRACT:
This paper presents a dead-beat predictive direct power control (DPC) strategy and its improved
voltage-vector sequences for reversible three-phase grid-connected voltage-source converters (VSCs). The
instantaneous variation rates of active and reactive powers, by applying each converter voltage vector in 12
different sectors, are deduced and analyzed. Based on the power variation rates, it is found that the values of
the predicted duration times for the two conventional active converter voltage vectors are less than zero
when the grid-connected VSC operates as either a rectifier or an inverter. In order to solve this issue, two
new alternative vector sequences are proposed and compared. Experimental results on a 1.5 kW reversible
grid-connected VSC system are presented to validate the feasibility of the proposed voltage-vector
sequences on the dead-beat predictive DPC strategy.

More Related Content

What's hot

Novel coordinated voltage control for hybrid micro grid with islanding capabi...
Novel coordinated voltage control for hybrid micro grid with islanding capabi...Novel coordinated voltage control for hybrid micro grid with islanding capabi...
Novel coordinated voltage control for hybrid micro grid with islanding capabi...I3E Technologies
 
Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...Ecwaytech
 
Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...Ecwayt
 
A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...
A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...
A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...Projectsatbangalore
 
A series lc-filtered active damper with grid disturbance rejection for ac pow...
A series lc-filtered active damper with grid disturbance rejection for ac pow...A series lc-filtered active damper with grid disturbance rejection for ac pow...
A series lc-filtered active damper with grid disturbance rejection for ac pow...I3E Technologies
 
JPEEE1440 Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...
JPEEE1440   Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...JPEEE1440   Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...
JPEEE1440 Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...chennaijp
 
Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power Applications
Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power ApplicationsCascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power Applications
Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power ApplicationsProjectsatbangalore
 
Capacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC Converter
Capacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC ConverterCapacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC Converter
Capacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC Converterbest buddha e smart technologies
 
12 11jan17 24 oct16 13127 28779-1-ed(edit-new)
12 11jan17 24 oct16 13127 28779-1-ed(edit-new)12 11jan17 24 oct16 13127 28779-1-ed(edit-new)
12 11jan17 24 oct16 13127 28779-1-ed(edit-new)IAESIJEECS
 
Improved dynamic response of dstatcom using genetic algorithm
Improved dynamic response of dstatcom using genetic algorithmImproved dynamic response of dstatcom using genetic algorithm
Improved dynamic response of dstatcom using genetic algorithmAlexander Decker
 
Elect principles 2 three phase systems
Elect principles 2   three phase systemsElect principles 2   three phase systems
Elect principles 2 three phase systemssdacey
 
Enhancing the ride through capability of dc-link voltage in npc multilevel un...
Enhancing the ride through capability of dc-link voltage in npc multilevel un...Enhancing the ride through capability of dc-link voltage in npc multilevel un...
Enhancing the ride through capability of dc-link voltage in npc multilevel un...I3E Technologies
 

What's hot (12)

Novel coordinated voltage control for hybrid micro grid with islanding capabi...
Novel coordinated voltage control for hybrid micro grid with islanding capabi...Novel coordinated voltage control for hybrid micro grid with islanding capabi...
Novel coordinated voltage control for hybrid micro grid with islanding capabi...
 
Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...
 
Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...Control of improved full bridge three-level dcdc converter for wind turbines ...
Control of improved full bridge three-level dcdc converter for wind turbines ...
 
A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...
A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...
A Three-Phase Inverter for a Standalone Distributed Generation System: Adapti...
 
A series lc-filtered active damper with grid disturbance rejection for ac pow...
A series lc-filtered active damper with grid disturbance rejection for ac pow...A series lc-filtered active damper with grid disturbance rejection for ac pow...
A series lc-filtered active damper with grid disturbance rejection for ac pow...
 
JPEEE1440 Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...
JPEEE1440   Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...JPEEE1440   Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...
JPEEE1440 Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Pow...
 
Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power Applications
Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power ApplicationsCascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power Applications
Cascaded Two-Level Inverter-Based Multilevel STATCOM for High-Power Applications
 
Capacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC Converter
Capacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC ConverterCapacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC Converter
Capacitor Voltage Control Strategy for Half-Bridge Three-Level DC/DC Converter
 
12 11jan17 24 oct16 13127 28779-1-ed(edit-new)
12 11jan17 24 oct16 13127 28779-1-ed(edit-new)12 11jan17 24 oct16 13127 28779-1-ed(edit-new)
12 11jan17 24 oct16 13127 28779-1-ed(edit-new)
 
Improved dynamic response of dstatcom using genetic algorithm
Improved dynamic response of dstatcom using genetic algorithmImproved dynamic response of dstatcom using genetic algorithm
Improved dynamic response of dstatcom using genetic algorithm
 
Elect principles 2 three phase systems
Elect principles 2   three phase systemsElect principles 2   three phase systems
Elect principles 2 three phase systems
 
Enhancing the ride through capability of dc-link voltage in npc multilevel un...
Enhancing the ride through capability of dc-link voltage in npc multilevel un...Enhancing the ride through capability of dc-link voltage in npc multilevel un...
Enhancing the ride through capability of dc-link voltage in npc multilevel un...
 

Viewers also liked

Digital plug in repetitive controller for single-phase bridgeless pfc converters
Digital plug in repetitive controller for single-phase bridgeless pfc convertersDigital plug in repetitive controller for single-phase bridgeless pfc converters
Digital plug in repetitive controller for single-phase bridgeless pfc convertersEcwaytech
 
Saurabh Mangal - Resume
Saurabh Mangal - ResumeSaurabh Mangal - Resume
Saurabh Mangal - ResumeSaurav M
 
Integration and operation of a single phase bidirectional inverter with two b...
Integration and operation of a single phase bidirectional inverter with two b...Integration and operation of a single phase bidirectional inverter with two b...
Integration and operation of a single phase bidirectional inverter with two b...Ecwaytech
 
Analysis, design, and performance evaluations of an edge resonant switched ca...
Analysis, design, and performance evaluations of an edge resonant switched ca...Analysis, design, and performance evaluations of an edge resonant switched ca...
Analysis, design, and performance evaluations of an edge resonant switched ca...Ecwaytech
 
Newsletter dated 10.06.2015
Newsletter dated 10.06.2015Newsletter dated 10.06.2015
Newsletter dated 10.06.2015Rajiv Bajaj
 

Viewers also liked (9)

Seeing in B&W
Seeing in B&WSeeing in B&W
Seeing in B&W
 
Digital plug in repetitive controller for single-phase bridgeless pfc converters
Digital plug in repetitive controller for single-phase bridgeless pfc convertersDigital plug in repetitive controller for single-phase bridgeless pfc converters
Digital plug in repetitive controller for single-phase bridgeless pfc converters
 
Saurabh Mangal - Resume
Saurabh Mangal - ResumeSaurabh Mangal - Resume
Saurabh Mangal - Resume
 
Sabrina_Resume2
Sabrina_Resume2Sabrina_Resume2
Sabrina_Resume2
 
Resume
ResumeResume
Resume
 
Integration and operation of a single phase bidirectional inverter with two b...
Integration and operation of a single phase bidirectional inverter with two b...Integration and operation of a single phase bidirectional inverter with two b...
Integration and operation of a single phase bidirectional inverter with two b...
 
Analysis, design, and performance evaluations of an edge resonant switched ca...
Analysis, design, and performance evaluations of an edge resonant switched ca...Analysis, design, and performance evaluations of an edge resonant switched ca...
Analysis, design, and performance evaluations of an edge resonant switched ca...
 
Car care
Car careCar care
Car care
 
Newsletter dated 10.06.2015
Newsletter dated 10.06.2015Newsletter dated 10.06.2015
Newsletter dated 10.06.2015
 

Similar to Improved voltage vector sequences on dead-beat predictive direct power control

A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...IJMER
 
A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...
A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...
A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...ijiert bestjournal
 
POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...
POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...
POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...ijiert bestjournal
 
Capacitor current analysis of a three-level neutral point clamped converter u...
Capacitor current analysis of a three-level neutral point clamped converter u...Capacitor current analysis of a three-level neutral point clamped converter u...
Capacitor current analysis of a three-level neutral point clamped converter u...IJECEIAES
 
Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...
Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...
Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...Kashif Mehmood
 
Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...
Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...
Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...RSIS International
 
129 venezuelan static var compensator
129 venezuelan static var compensator129 venezuelan static var compensator
129 venezuelan static var compensatorwmelis
 
Augmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow ControllerAugmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow ControllerIJERA Editor
 
6 design of an optimized modulation 17
6 design of an   optimized modulation 176 design of an   optimized modulation 17
6 design of an optimized modulation 17Alexander Decker
 

Similar to Improved voltage vector sequences on dead-beat predictive direct power control (20)

A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
A High Performance PWM Voltage Source Inverter Used for VAR Compensation and ...
 
A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...
A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...
A NOVEL TCHNOLOGY FOR HARMONICS AND UNBALANCE COMPENSATION IN ELECTRIC TRACTI...
 
Modeling and Simulation of Three Phase D-SVC for Load Compensation
Modeling and Simulation of Three Phase D-SVC for Load CompensationModeling and Simulation of Three Phase D-SVC for Load Compensation
Modeling and Simulation of Three Phase D-SVC for Load Compensation
 
A04 05 0110
A04 05 0110A04 05 0110
A04 05 0110
 
POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...
POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...
POWER SYSTEM STABILITY OF MULTI MACHINE BY USING STATIC SYNCHRONOUS SERIES CO...
 
A new switching look-up table for direct power control of grid connected 3L-N...
A new switching look-up table for direct power control of grid connected 3L-N...A new switching look-up table for direct power control of grid connected 3L-N...
A new switching look-up table for direct power control of grid connected 3L-N...
 
Hn3613321337
Hn3613321337Hn3613321337
Hn3613321337
 
G046033742
G046033742G046033742
G046033742
 
Capacitor current analysis of a three-level neutral point clamped converter u...
Capacitor current analysis of a three-level neutral point clamped converter u...Capacitor current analysis of a three-level neutral point clamped converter u...
Capacitor current analysis of a three-level neutral point clamped converter u...
 
H04945260
H04945260H04945260
H04945260
 
Ijetr021124
Ijetr021124Ijetr021124
Ijetr021124
 
Ijetr021124
Ijetr021124Ijetr021124
Ijetr021124
 
Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...
Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...
Voltage-current Double Loop Control Strategy for Magnetically Controllable Re...
 
Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...
Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...
Power Factor Improvement in Distribution System using DSTATCOM Based on Unit ...
 
129 venezuelan static var compensator
129 venezuelan static var compensator129 venezuelan static var compensator
129 venezuelan static var compensator
 
Augmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow ControllerAugmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
Augmentation of Real & Reactive Power in Grid by Unified Power Flow Controller
 
6 design of an optimized modulation 17
6 design of an   optimized modulation 176 design of an   optimized modulation 17
6 design of an optimized modulation 17
 
Gy3512171221
Gy3512171221Gy3512171221
Gy3512171221
 
Ci36507510
Ci36507510Ci36507510
Ci36507510
 
Performance Investigation of a Monopolar HVDC Transmission System Feeding a ...
Performance Investigation of a Monopolar HVDC Transmission  System Feeding a ...Performance Investigation of a Monopolar HVDC Transmission  System Feeding a ...
Performance Investigation of a Monopolar HVDC Transmission System Feeding a ...
 

Improved voltage vector sequences on dead-beat predictive direct power control

  • 1. IMPROVED VOLTAGE-VECTOR SEQUENCES ON DEAD-BEAT PREDICTIVE DIRECT POWER CONTROL OF REVERSIBLE THREEPHASE GRID-CONNECTED VOLTAGE-SOURCE CONVERTERS ABSTRACT: This paper presents a dead-beat predictive direct power control (DPC) strategy and its improved voltage-vector sequences for reversible three-phase grid-connected voltage-source converters (VSCs). The instantaneous variation rates of active and reactive powers, by applying each converter voltage vector in 12 different sectors, are deduced and analyzed. Based on the power variation rates, it is found that the values of the predicted duration times for the two conventional active converter voltage vectors are less than zero when the grid-connected VSC operates as either a rectifier or an inverter. In order to solve this issue, two new alternative vector sequences are proposed and compared. Experimental results on a 1.5 kW reversible grid-connected VSC system are presented to validate the feasibility of the proposed voltage-vector sequences on the dead-beat predictive DPC strategy.