1. CURRICULUM VITAE
HAIDER ALI
Electrical Engineer
Career Objective:
A self motivated person able to work on own initiative and as part of a
team proven leadership skills involving managing, developing and motivating teams to achieve
their objectives. Seeking employment in a dynamic organization that provides a challenging
opportunity to combine exceptional interpersonal, analytical, presentation and computer skills.
Personal Information:
Name Haider Ali
Father’s name Muhammad Munir
Date of Birth 03/01/1987
C.N.I.C No. 35201-6123615-1
Present Address H. No.150 St. No.8 Umer Block, Chungi Gujjar Pura Zarar
Shaheed Road, Lahore Cantt
Religion Islam
E-mail Haider_625@hotmail.com
Cell 0321-4905656, 0301-4327386, 0332-4332516
Education:
Degree Year University/Board Marks %age
B. Tech (Pass)
(Electrical)
2011 Preston University, Lahore
3.12
(CGPA)
D.A.E (Electrical) 2006
Punjab Board of Technical
Education, Lahore
71
Matric 2003 B.I.S.E Lahore 65
Diploma In Office
Management
2005
Institute Of Digital Logics
& Computer Sciences
75
Diploma In Computer
Hardware Engineering
2005 Nemcon Computer Institute 79
Self Assessment:
Strong analytical negotiation as well as good interpersonal communication skills.
Good in understanding and speaking English, Urdu and Punjabi.
Self starter, ambitious, proactive, punctual, and innovative professional.
Always give top priority to improvement of knowledge.
2. Experience:
Two years experience in Domestic Electrical Works.
One year’s worked experience in Multi Engineering International (Head Office 23-B,
Main Bazaar Canal Park Gulberg II Lahore) as an Electrician.(01/8/2005 To 01/08/2006)
Four year worked experience in TransfoPower Industries, near Thokar Niaz Beg Lahore
(01/02/2007 to 31/05/2011) as Quality Assurance Inspector-Transformer.
Worked in Ittehad Enterprises (Plot #.2, Street #.3, Opp Govt Girls School, near water
land park, Saggian Bypass Lahore-Pakistan) as an Electrical Engineer. (01/06/2011 To
01/02/2015)
Now working in World Over Engineering Pvt Limited (Sadoki Nangr Phattak Near
Ramay Textile Mills.) As Testing Engineer (01/02/2015 To Till Now)
Basic Job Description:
Worked as Quality Assurance Inspector-Transformer.
Testing of Distribution Transformer (10KVA, 25KVA, 100KVA, 200KVA, 400 KVA,
630 KVA, 1000 KVA, 1500 KVA, 3000 KVA, 5000 KVA).
Physical and Dimensional Inspection Pad Mounted Transformers.
All Testing of distribution Transformer’s Oil Test.
Checked the quality of Transformer Equipments.
I have performed following tests in Quality Assurance Department;
Transformer Routine Tests:
Transformer Turn Ratio Test
Induced Voltage Test
Power Frequency Test (High Voltage)
Open Circuit Test
Short Circuit Test
Winding Resistance Test
Insulation Resistance Test
Bird Protection Test
Vector Group Test
Core Losses Test (before use in Transformer)
Temperature Rise Test
Transformer Insulating Oil Tests:
Breakdown Voltage Test
Pour Point Test
Viscosity Test
Gravity Test
Oil Acidity Test
Flash Point Test
I have performed following tests in Quality Control Department;
All Hardware use in Transformer Manufacturing
Enameled Copper Wire Tests
Paper Insulated Copper Strip Test
Reference: