Enclosed yards or courts used for exit discharge in
accordance with 23.2.7.1 shall be of sufficient size to accommodate
all occupants at a distance of not less than 50 ft (15 m)
from the building while providing a net area of 15 ft2 (1.4 m2)
per person.
1. Ref No:MEC:Dhaka:April:2022:18
PROPOSED FIRE SAFETY PLAN DRAWING
PROJECT NAME AND ADDRESS
DR. MD. ABDUL WAKIL
OWNER'S NAME
OCCUPANCY CLASSIFICATION
BUILDING TYPE
PREPARED BY
A2
R.C.C BUILDING
MART ENGINEERING & CONSULTANCY
HOTLINE:-01717-432054, 01670-212478
ENGR. M.A. RASHID TIPU,CFPS
Certified Fire Protection Specialist
Ba-08, South Badda, Gulshan, (Behind of shooting club)
Dhaka-1212, Bangladesh.
Mobile:-01717-432054, 01670-212478
APPROVED BY
DEPARTMENT OF
FIRE SERVICE & CIVIL DEFENSE
38-46, ROAD-KAZI-ALAUDDIN ROAD,
SIDDIQUE BAZAR, DHAKA 1000
FAISAL MAHBUB
IAB Membership & Rajuk Registration No-M-015
Cell: 01980001277
ARCHITECT :
AHMED YOUSUF HOSSAIN
HOUSE # 7, FLAT # C/2, ROAD-04.
GULSHAN # 1, DHAKA-1212
OWNER'S NAME :
WE KILL FIRE BEFORE IT KILLS YOU
CONSULTANT:
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
2. LAYOUT DRAWING OF GROUND FLOOR
05
06
07
09
INDEX & LEGEND
00 TOP SHEET
01
02
03
04
08
LAYOUT DRAWING OF 1ST FLOOR
MASTER PLAN MASTER PLAN
10
POSITIVE SUCTION FIRE PUMP SCHEMATIC
DIAGRAM AND INSTALLATION DETAILING
FIRE ALARM RISER DIAGRAM
ELEVATION & SECTION VIEW
11
BUILDING AREA :
RESIDENTIAL & REFUGE AREA
LAYOUT DRAWING OF SUBSTATION
INSTRUCTIONS: SUB-STATION ROOM
ROOF FLOOR : PROPOSED LIGHTING PROTECTION SYSTEM (LPS).
13
PAGE NO. DRAWING TITLE DESCRIPTION
INDEX
12
GOOGLE MAP
FIRE PUMP ROOM, WATER RESERVOIR,PARKING AREA
14
FIRE CONTROL PANEL & 150 KVA SUBSTATION ROOM,
100 KVA GENERATOR & PARKING AREA
PROPOSED SINGLE LINE DIAGRAM (SLD)
15
COMMUNITY HALL
R. S MOUZA MAP
LAYOUT DRAWING OF 2ND TO 14TH FLOOR
LAYOUT DRAWING OF 8TH FLOOR
LAYOUT DRAWING OF 15TH FLOOR & ROOF FLOOR
RESIDENTIAL AREA
ROOF OF COMMON ROOM
16
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 01
3. Total area
01 1st Floor (Community) 122.26
Sl. No. Floor Total (Sqm)
14 15th Floor / Roof Floor 105.90
02 2nd Floor 223.27
03 3rd Floor
04 4th Floor
05 5th Floor
06 6th Floor
07 7th Floor
08 8th Floor
09 9th Floor
10 10th Floor
11 11th Floor
12 12th Floor
13 13th Floor
13 14th Floor
223.27
223.27
223.27
223.27
223.27
223.27
223.27
223.27
223.27
223.27
223.27
223.27
Ground floor 348.77
3479.44
TOTAL FLOOR AREA:
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 02
4. Google Map
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 04
5. 1
8
.
2
9
m
W
I
D
E
R
O
A
D
19.65m
22.11m
2
0
.0
0
m
25.61m
FIRE STAIR
5.08mx2.00m
FIRE LIFT
1.96mx2.44m
GUARD
POST
2.38mx1.40m
E
N
T
R
Y
E
X
IT
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
3.16m
3.05m
SW
SEPTIC
TANK
TO SURFACE DRAIN
LT Panel
PROPOSED UNDER GROUND
FIRE WATER RESERVOIR
50,000 US GALLON
Switchgear room
10'-3X7'-3"
150KVA
Transformer
Room
100KVA
Generator Room
FHC
Standpipe Riser
& Drain Pipe
Fire Hose
Connection
Ø65mm
Landing
valve
FDC
Ø150mm
Pillar
Hydrant
2
WAY(65MM)
FIRE
DEPARTMENT
CONNECTION
Ø150mm
Underground Pipe
Fire Control
Room
PROPOSED 16 - STORIED
RESIDENTIAL BUILDING
STAIR
2.87mx4.27m
PROPOSED
FIRE PUMP ROOM
N
MASTER PLAN
SCALE :- 1 : 200
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 05
6. 226
235
234
236
887
227
129
233
902
228
232
128
888 130
N
O
R. S MOUZA MAP
SCALE : 16" = 1 MILE
PROPOSED PLOT
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 03
7. 1
8
.
2
9
m
W
I
D
E
R
O
A
D
19.65m
22.11m
2
0
.0
0
m
25.61m
FIRE STAIR
5.08mx2.00m
FIRE LIFT
1.96mx2.44m
LIFT
LOBBY
2.21mx1.57m
STAIR
2.87mx4.27m
LIFT
1.96mx1.52m
Level
+
0.76m
GUARD
POST
2.38mx1.40m
E
N
T
R
Y
E
X
IT
UP
GREEN
GREEN
GREEN
GREEN
GREEN
GREEN
TOILET
1.27mx2.29m
DRIVER'S
SITTING
1.40mx3.02m
D R I V E W A Y
3.16m
CAR
DROP
OFF
AREA
3.05m
UP
SW
SEPTIC
TANK
TO SURFACE DRAIN
SYMBOL SYMBOL NAME Q.T
03
Smoke Detector 07
Fire Alarm Control Panel 01
Horn With Light 06
Manual call points
P 03
SYMBOL SYMBOL NAME Q.T SYMBOL SYMBOL NAME Q.T
02
Fire Hose Connection Class- III 01
Fire Door 2 Rated 06
17
Sprinkler K- 11.2
FIRST AID BOX 04
Extinguisher (ABC & CO2) 07
ADDRESSABLE OUTPUT MODULE
ABC
CO2
SYMBOL SYMBOL NAME Q.T
02
02
03
03
FM 200 GAS Nozzle 360°
100 LETTER FM 200 GAS CYLINDER
A Actuator
P Pressure switch
FM-200 System Control Panel 02
Heat Detector
NOVEC-1230
FACP
FACP
POSITIVE AIR PRESSURIZED.
GROUND FLOOR: 150KVA SUB-STATION, 100KVA GENERATOR, FIRE CONTROL ROOM & FIRE PUMP ROOM
Floor Area:2000.04 sft
Scale : 1:100
FOAM
FACP
FM-200 System Control Panel
100 LETTER FM 200 FOAM CYLINDER
FM 200 FOAM Nozzle 360°
01
01
01
N
LT Panel
EXHAUST
SILENCER
PROPOSED UNDER GROUND
FIRE WATER RESERVOIR
50,000 US GALLON
UP
DN
P
500 GPM
ELECTRIC
PUMP
500 GPM
DIESEL
ENGINE
PUMP
10 GPM
JOCKEY
PUMP
P
Safety
Lobby
Safety Lobby
Fire Control Room
1.27mx1.52m
FACP
P
ABC
CO2
100
LETTER
CYLINDER
100
LETTER
CYLINDER
Switchgear room
10'-3X7'-3"
P A
Exit
Exit P A
NOVEC-1230
FACP ABC
CO2
150KVA
Transformer Room
9'-6''x9'-10''
Novec-1230 Gas Fire
Suppression System
ABC
CO2
FOAM
FACP
Exit
100
LETTER
FOAM
CYLINDER
100KVA
Generator
Room
7'-7''x15'-0''
Foam
Fire
Suppression
system
NOVEC-1230
FACP
ABC
CO2
ABC
CO2
ABC
CO2
ABC
CO2
ABC
CO2
FHC
Standpipe Riser
& Drain Pipe
Fire Hose
Connection
ABC
CO2
POSITIVE AIR
PRESSURIZED.
Ø65mm
Landing
valve
4 HOUR FIRE
RATED WALL
4 HOUR
RATED WALL
4 HOUR FIRE
RATED WALL
4 HOUR FIRE
RATED WALL
Sprinkler Head
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø32mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø25mm
Ø32mm Ø50mm
Ø25mm
Ø25mm
Ø65mm Ø65mm Ø65mm
Ø65mm
Ø50mm
WF
AIM
AIM
To
Nearest
Drain
Pit
Zone
Control
Valve
P
A
AIM AIM AIM AIM AIM
AIM AIM AIM AIM AIM
FHC
AIM 12
SYMBOL SYMBOL NAME Q.T
00
Sprinkler K- 11.2
PILLAR HYDRANT 01
FIRST AID BOX 00
01
2 way(65mm) Fire Department Connection
FDC
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 06
8. INSTRUCTIONS: ELECTRICAL SUB STATION ROOM
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 07
9. LT Panel
HT
Panel
SYMBOL SYMBOL NAME Q.T
03
Heat Detector
Smoke Detector 03
ABORT SWITCH 03
Horn With Light 03
Manual call points
P 00
Actuator SWITCH 03
PRESSURE SWITCH 03
03
FIRST AID BOX
Fire Door 2 Rated 03
A
P
FM 200 GAS NOZZLE 360°
100 LETTER FM 200 GAS CYLINDER
FM-200 System Control Panel 01
Extinguisher (ABC & CO2) 5KG 03
4 HOUR RATED WALL
NOVEC-1230
FACP
02
02
FOAM NOZZLE 360°
FOAM
FACP
FOAM System Control Panel
100 LETTER FOAM CYLINDER
01
01
01
Floor Area: 320 sft
Scale : 1:100
ABC
CO2
AS PER
DRAWING
ABC
CO2
ABC
CO2
FOAM
FACP
Exit
100
LETTER
CYLINDER
100
LETTER
FOAM
CYLINDER
100
LETTER
CYLINDER
150KVA
Transformer Room
9'-6''x9'-10''
Novec-1230 Gas Fire
Suppression System
Switchgear room
10'-3X7'-3"
100KVA
Generator
Room
7'-7''x15'-0''
Foam
Fire
Suppression
system
P A
150 KVA Sub-Station, 100 KVA Generator
NOVEC 1230 FIRE SUPPRESSION SYSTEM
Exit
Exit P A
NOVEC-1230
FACP ABC
CO2
N
P
A
NOVEC-1230
FACP
11'-6"
8'-10"
15'-9"
10'-1"
5'-10"
7'-3"
1. Electric backup for fire Lift
2. Electric backup for Stair case Positive Air Pressure.
3. Electric backup Ventilation system with Cross fresh air
4. Electric backup Fire Pump/Jockey pump
5. All signes Including Backup Emergency Exit sing
Generator & Emergency power Generator Room
1. Separation Rating
2. Wall: 4 Hour, Door: 2 Hour Fire Rating
3. Suppression: Clean Agent
4. Capacity :100KVA
5. Location : Ground Floor
TRANSFORMER & SWITCHGEAR ROOM
1. Separation Rating
2. Wall: 4 Hour, Door: 2 Hour Fire Rating
3. Suppression: Clean Agent
4. Capacity : 150KVA
5. Location : Ground Floor
NOTE:
SCHEMATIC DRAWING FOR
AUTOMATIC CLEAN AGENT
DISTRBUTION SYSTEM FOR
SUBSTATION ROOM SIZE
APPROXIMATELY 220SFT
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 08
10. LIFT
LOBBY
1.68mx1.57m
TOILET
2.21mx1.30m
COMMUNITY HALL
7.76mx9.73m
ROOF
OF
ELECTRO-
MECHANICAL
ROOM
UP
DN
FIRE STAIR
5.08mx2.00m
STAIR
2.87mx4.27m
Safety
Lobby
Safety Lobby
FHC
Standpipe Riser
& Drain Pipe
Fire Hose
Connection
Ø65mm
Landing
valve
FIRE LIFT
1.96mx2.44m
LIFT
1.96mx1.52m
ABC
CO2
4 HOUR FIRE
RATED WALL
4 HOUR FIRE
RATED WALL
POSITIVE AIR
PRESSURIZED.
P
SYMBOL SYMBOL NAME Q.T
00
Smoke Detector
Fire Alarm Control Panel
Horn With Light
Manual call points
P
SYMBOL SYMBOL NAME Q.T SYMBOL SYMBOL NAME Q.T
Standpipe Riser & Drain Pipe 01
Fire Hose Connection Class- III
Fire Door 2 Rated
00
Sprinkler K- 11.2
PILLAR HYDRANT 01
FIRST AID BOX 00
Extinguisher (ABC & CO2)
00
01
2 way(65mm) Fire Department Connection
4 HOUR RATED WALL
ABC
CO2
Heat Detector
FDC
FACP
POSITIVE AIR PRESSURIZED.
1ST FLOOR: FACP ROOM & RESIDENTIAL AREA
Floor Area:122.26Sqm
Scale : 1:100
06
01
01
02
01
04
AS PER
DRAWING
01
N
FHC
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 09
13. LIFT
MACHINE ROOM
1.96mx6.05m
4.16m
1.09m
13.55m
1.85m
7.04m
2.90m
7.52m
13.55m
8.23m
2.67m
3.81m
4.50m
COMMON ROOM
7.76mx7.21m
9.86m
Raised 1.75m
Raised 1.75m
DN
1.78m
DN
TOILET
2.73mx1.27m
FIRE STAIR
5.08mx2.00m
STAIR
2.87mx4.27m
Safety
Lobby
Safety Lobby
ABC
CO2
FHC
Standpipe Riser
& Drain Pipe
Fire Hose
Connection
Ø65mm
Landing
valve
4 HOUR
RATED WALL
4 HOUR FIRE
RATED WALL
P
POSITIVE AIR
PRESSURIZED.
R
O
O
F
W
A
T
E
R
D
R
A
I
N
A
G
E
SLOPE
1:200
R
O
O
F
W
A
T
E
R
D
R
A
I
N
A
G
E
S
L
O
P
E
1
:
2
0
0
R
O
O
F
W
A
T
E
R
D
R
A
I
N
A
G
E
S
L
O
P
E
1
:
2
0
0
R
O
O
F
W
A
T
E
R
D
R
A
I
N
A
G
E
S
L
O
P
E
1
:
2
0
0
OPEN SKY
SYMBOL SYMBOL NAME Q.T
00
Smoke Detector
Fire Alarm Control Panel
Horn With Light
Manual call points
P
SYMBOL SYMBOL NAME Q.T SYMBOL SYMBOL NAME Q.T
Standpipe Riser & Drain Pipe 01
Fire Hose Connection Class- III
Fire Door 2 Rated
01
Class-I Hose Connection
PILLAR HYDRANT 00
FIRST AID BOX 01
Extinguisher (ABC & CO2)
00
00
2 way(65mm) Fire Department Connection
4 HOUR RATED WALL
ABC
CO2
Heat Detector
FDC
FACP
POSITIVE AIR PRESSURIZED.
15TH FLOOR & ROOF FLOOR: RESIDENTIAL AREA
Floor Area:105.90 SQM
Scale : 1:100
08
02
03
02
01
03
AS PER
DRAWING
02
ABC
CO2
ABC
CO2
P
FHC
N
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 12
14. ROOF OF STAIR
& O. H. W. R.
20000 LITTER
ROOF OF COMMON ROOM
ROOF OF LIFT
MACHINE ROOM
ROOF
OF
FIRE
STAIR
OPEN SKY
10'
8'
Grounding Electrode
No:01
Grounding Electrode (Size: Dia12.7mm)
Bounding Conductor (Width
12.7mm & Thickness 1.30mm)
Down Conductor-01
Size: 12mm Dia Copper Rod
10'
8'
Grounding Electrode
No:02
Grounding Electrode (Size: Dia12.7mm)
Bounding Conductor (Width
12.7mm & Thickness 1.30mm)
Down Conductor-01
Size: 12mm Dia Copper Rod
10'
8'
Grounding Electrode
No:04
Grounding Electrode (Size: Dia12.7mm)
Bounding Conductor (Width
12.7mm & Thickness 1.30mm)
Down Conductor-01
Size: 12mm Dia Copper Rod
10'
8'
Grounding Electrode
No:03
Grounding Electrode (Size: Dia12.7mm)
Bounding Conductor (Width
12.7mm & Thickness 1.30mm)
Down Conductor-01
Size: 12mm Dia Copper Rod
Roof Floor : Proposed Lighting Protection System (LPS).
LEGEND
Down Conductor (Solid
Rod ɸ-12mm Copper)
Bounding Conductor
(Solid or Standard
ɸ-17AWG Copper)
Earth Symbol
Earthing Rod (ɸ-12mm
Copper)
Air Terminal (ɸ-12mm
Copper) In The Periphery
top of the Building, Hight
2ft.
Calculation of Down Conductor,
DC = Total Periphery/100
= 569'/100
= 5.69
= 06 Pcs
Required Materials Calss-II
Follow Standard- NFPA780
Air Terminal Top
(ɸ-12mm Copper) In The
Periphery top of the
Building, Hight 2ft.
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 13
16. +10'-0"
1'-8"
Delivery
Pipe
,
Ø
125
mm
Delivery
Pipe
,
Ø
50
mm
Delivery
Pipe
,
Ø
125
mm
Ø150 mm
Header Pipe
Level (-) 3'-0"
Ø125 mm Suction for Engine Driven Fire Pump, Level (-)
12'-0"
Ø65 mm Suction for Motor Driven Jockey Pump, Level (-)
12'-0"
Ø125 mm Suction for Motor Driven Fire Pump, Level (-) 12'-0"
P SITIVE SUCTI N FIRE PUMP SCHEM TIC
DI GR M ND INST LL TI N DET ILING
Ø125mm Relief valve discharge Pipe,
Level (+) 0'-6"
Ø150mm Delivery Pipe,
Level (-) 3'-0"
64'-1"
Ø150mm Pipe from Deep Tubewell
to Fill the Underground
Water Reservore,
Level (-) 1'-0"
Level (-) 0'-0"
Level (+) 0'-0"
Water Level (-) 1'-0"
32'-4"
TS
TS
TS
Water Level Gauge
Ø150mm Pipe
WF
TS
10'-0"
Ø125mm Test Header
Pipe, Level (+) 0'-6"
Ø150mm Flow Meter
Pipe, Level (+) 0'-6"
WF
Ø50mm Drain Pipe
To Nearest Drain Pit
AIM
AIM Ø150mm
Standpipe Riser-01
Class-III Hose
Connection
Ø65mm
Branch Pipe
Proposed Fire Pump Schedule (Brand: , ......)
Type of Pump
Type of Driver
Rated Capacity (US GPM)
Rated Pressure (bar.g)
Rated Head (FT.)
M
a
i
n
F
i
r
e
P
u
m
p
(
E
P
) Stand By Fire Pump (DP) Jockey Pump (JP)
500.00
Horizontal Spilt Case
Centifugal
Vertical Multi-stage
Centifugal
Electrical Motor Diesel Engine Electrical Motor
100.00
10.00
Horizontal Spilt Case
Centifugal
Pump RPM 2900
500.00
100.00
10.00
2900
25.00
110.00
11.0
3000
Class- I Landing valve (Ø65mm Landing Valve)
Standpipe Riser & Drain Pipe
Pillar Hydrant
(2xØ65mm/Ø150mm)
Four Way Fire Department Connection
(4xØ65mm/Ø150mm)
LEGEND
S MB L S MB L N ME T
00
14
01
01
01
Class - III Hose Connection
(Ø40mm Pressure Hydrant Valve with Ø38mm
Canvas Hose & Ø38mm Variable Nozzle & Within Cabinate)
FIRE DEPARTMENT
CONNECTION -
2 WAY(65MM)
NON RETURN
VALVE: 100MM
Pillar Hydrant
AIR RELIFE VALVE
PRESSURE GAUGE
BALL VALVE
BALL VALVE
Ø150mm
Standpipe Riser-01
FDC
L
+10'-0"
Ø65mm
Branch Pipe
N TO L
Class-III Hose
Connection
Ø65mm
Branch Pipe
ROO L
FDC
Ø40mm
Branch Pipe
Ø40mm
Branch Pipe
PROPOSED UNDER GROUND
WATER RESERVOIR
60,000 US GALLON
Class-III Hose
Connection
Ø65mm
Branch Pipe
Ø40mm
Branch Pipe
ROUN L
+10'-0"
Ø65mm
Branch Pipe
Class-III Hose
Connection
Ø65mm
Branch Pipe
Ø40mm
Branch Pipe
Ø50mm
Pipe
W
F
AIM
AIM
To Nearest
Drain Pit
Zone Control
Valve Sprinkler
Ø150mm
Cross main
HOSE NOZZE
SPRING LOCK
HANDLE
1½" Ø CANVASS HOSE
2½" Ø LANDING VALVE
FIRE HOSE CABINET
(2'-4"X10"X2'-8")
WIRRED GLASS
1½" Ø CONTROLLED
PRESSURE HYDRNT
VALVE
6"
Ø
STANDPIPE
RISER
BALL VALVE
2½" Ø M.S. PIPE
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 15
17. SYMBOL
LEGEND WITH SPECIFICATION
SYMBOL NAME
Horn With Light
Smoke Detector
Heat Detector
Malti Detector Addressable
Manual call points
Addressable Fire Alarm Control Panel
Addressable Output Module
P
Addressable Input Module
AOM
AIM
SYMBOL SYMBOL NAME
03
06
00
22
Q.T
19
00
12
Q.T
AIM AIM AIM AIM AIM
AIM AIM AIM AIM AIM
MAIN FIRE ALARM CONTROL PANEL, No-01
2 LOOPS
BATTERY CAPACITY = 10 AH
SECURITY ROOM (GF)
AUX-ILIARY
POWER
SUPPLY
(NAC
CIRCUIT)
SOFTWARE INTERFACE WITH BMS SYSTEM
INTERFACE WITH PUBLIC ADDRESS
3 x 2.5rm wire from
primary power source
LOOP 2 LOOP 1
EOLR
FIRE ALARM RISER DIAGRAM
P
P
P
P P
P
P P
P
P
P
P
P P
P
P
P
EOLR
FACP
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 16
18. REB SUPPLY
M METER
11KV DROP OUT FUSE(100A)
11 KV LIGHTNING ARRESTER
G
12.7mm Dia Cu Conductor
(Body Earthing)
Earth Pit-9
Earth
Pit-8
Earth
Pit-7
12.7mm Dia Cu Conductor
12.7mm Dia Cu Conductor
100KVA Diesel Generator
440V, 50Hz, Prime-220KVA,
Standby-200KVA
12.7mm Dia Cu Conductor
12.7mm Dia Cu Conductor
12.7mm Dia Cu Conductor
12.7mm Dia Cu Conductor
EARTH PIT-6
EARTH PIT-5
EARTH PIT-4
EARTH PIT-3
(Neutral Earthing)
(Neutral Earthing)
(Body Earthing)
(Body Earthing)
100A ATS Panel
(Body Earthing)
150KVA TRANSFORMER
11KV / 415V,
Dyn11, 50Hz, Step Down.
%Z=6, OIL TYPE
1CX4X400RM NYY CABLE(TP+N)
630A TP MCCB
Adj-1
LT Panel
Load=497kw
Diversity Factor-40%
(Load=199KW)
3X50RM (NYSEYFGbY) HT CABLE
1CX4X150RM NYY CABLE(TP+N)
1CX4X150RM NYY CABLE(TP+N)
(Neutral Earthing)
PROPOSED SINGLE LINE DIAGRAM (SLD)
90KVAR
Door ECC=1X4.0 rm
CKT-
00
1CX4XX50
Sqmm
(TP+N)
NYY
ECC-
1CX1X25
Sqmm
BYA
CKT-
1
CKT-
2
CKT-
3
CKT-
4
CKT-
5
CKT-
6
CKT-
7
CKT-
8
CKT-
9
CKT-
10
CKT-
11
CKT-
12
CKT-
13
CKT-
14
Earth
Pit-10
12.7mm
Dia
Cu
Conductor
(Body Earthing)
Bus Bar- 372A (TP+N) & ECC- 186A, 30mmX8mm (TP+N) CU BUS BAR +20mmX6mm ECC
150A
TP
MCCB
CKT-
15
CKT-
16
CKT-
17
CKT-
18
CKT-
19
CKT-
20
CKT-
21
CKT-
22
CKT-
23
CKT-
24
CKT-
25
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
26
CKT-
27
CKT-
28
CKT-
29
CKT-
30
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
31
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
32
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
33
DB-1
1ST
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-2
2ND
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-3
3RD
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-4
4TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-5
5TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-6
6TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-7
7TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-8
8TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-1
1ST
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-1
1ST
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-1
1ST
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-2
2ND
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-2
2ND
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-2
2ND
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-3
3RD
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-3
3RD
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-3
3RD
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-4
4TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-4
4TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-4
4TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-5
5TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-5
5TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-5
5TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-6
6TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-6
6TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-6
6TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-7
7TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-7
7TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-7
7TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
CKT-
34
CKT-
35
CKT-
36
CKT-
37
CKT-
38
CKT-
39
CKT-
40
CKT-
41
CKT-
42
CKT-
43
CKT-
44
CKT-
45
CKT-
46
CKT-
47
CKT-
48
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
49
CKT-
51
CKT-
52
CKT-
53
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
54
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
55
DB-8
8TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-8
8TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-8
8TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
CKT-
50
DB-9
9TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-9
9TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-9
9TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-9
9TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-10
10TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-10
10TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-10
10TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-10
10TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-11
11TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-11
11TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-11
11TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-11
11TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-12
12TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-12
12TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-12
12TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-12
12TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-13
13TH
F
UNIT-A
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
40A
DP
MCB
1CX2X10
Sqmm
(SP+N)
BYA
ECC
1CX1X6
Sqmm
BYA
CKT-
56
40A
DP
MCB
CKT-
57
40A
DP
MCB
CKT-
58
DB-13
13TH
F
UNIT-B
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-13
13TH
F
UNIT-C
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
DB-13
13TH
F
UNIT-D
Load=7KW
Diversity
Factor-40%
(Load=2.8KW)
SPARE
SPARE
R
B
Y
B
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
B
Y
R
Y
1CX4XX70
Sqmm
(TP+N)
NYY
ECC-
1CX1X35
Sqmm
BYA
200A
TP
MCCB
R
B
YFire
Pump
DB
Load=80kw
1CX4XX70
Sqmm
(TP+N)
NYY
ECC-
1CX1X35
Sqmm
BYA
40A
TP
MCCB
Lift
DB
Load=15kw
1CX4XX70
Sqmm
(TP+N)
NYY
ECC-
1CX1X35
Sqmm
BYA
40A
TP
MCCB
Lift
DB
Load=15kw
1CX4XX70
Sqmm
(TP+N)
NYY
ECC-
1CX1X35
Sqmm
BYA
40A
TP
MCCB
Lift
DB
Load=15kw
R
B
Y
R
B
Y
R
B
Y
CKT-59
1CX4XX70
Sqmm
(TP+N)
NYY
ECC-
1CX1X35
Sqmm
BYA
40A
TP
MCCB
Lift
DB
Load=15kw
R
B
Y
LBS
12.7mm Dia Cu Conductor
EARTH PIT-2
12.7mm Dia Cu Conductor
EARTH PIT-1
PROJECT NAME & ADDRESS:
OWNER'S NAME / REPRESENTATIVE
PREPARED BY
ENGINEER
FIRE PROFESSIONAL
APPROVED BY
DEPARTMENT OF FIRE SERVICE
& CIVIL DEFENSE.
Head Office: 38-46, Road:
KaziAlauddin Road, Siddique Bazar, Dhaka.
SCALE
PAGE SIZE:
1:100
21-12-2021
A-3
DATE
CONSULTANT:
DESIGNER
ARCHITECT
PROPOSED 16 - STORIED RESIDENTIAL BUILDING
AT PLOT NO-03, ROAD NO - 201, SECTOR NO-02,
UNITED CITY, MADANI AVENUE, SATARKUL, DHAKA.
CS DAG - 391, RS DAG - 233 & 234
MOUZA - SATARKUL, PS - BADDA, DHAKA.
AHMED YOUSUF HOSSAIN
S/O - Mohammad Abdul Bari
MOTHERS NAME -Asiya Bari
House # 7, Flat # C/2, Road-04. Gulshan # 1,Dhaka-1212.
MART ENGINEERING & CONSULTANCY
Address: House -10,Road-03,(1st FL), Middle Badda, Gulshan
Badda Link ,Road, Dhaka-1212.
Mobile : +88017 - 17432054
PAGE NO : 17