Author name Welcome to FCG Middle East FZC – An International branch of  FCG Flameproof control gears Pvt.Ltd.- India
Author name Flameproof Equipment : The protective enclosure to not become an ignition / explosion source to the flammable gases/vapors/liquids/fumes/dusts/fibers  present in the Hazardous locations , which are explosive in nature while mixing with oxygen & lead to the explosion. An Electrical Equipment which requires to be a Flameproof, The Make & Break Contacts  The Hot Surface  Switching points Un organized cable harnessing Heavy Equipments running on Hi  Ampere capacity When it can be an ignition source by coming in contact of oxygen, flammable Sources as said above , the ignition source are exemplified as :
Explosion ONLY POSSIBLE AS PER BELOW EXPLANATION :
Major Products : Junction Boxes  : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Control Panels & Distribution Boards : As per Customer Application Local Control Station : Ex d & WP ,WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Switch Socket  : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC Push button station & Rotary Switch  : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC Light Fittings  : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Control Gear Box : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Cable Glands & Accessories : Ex d & WP for Gas Group IIA/IIB & IIC Clean Room Fittings  : Ex d & WP for Gas Group IIA/IIB Mis. Items  : Telephone, Pressure switch, Electronic Hooter, Bell, Ex-d & WP respectively for Gas Group IIA/IIB  for Hooter : IIA/IIB & IIC , Torch : intrinsically Safe EEx ia for mining industry
Major Products : Junction Boxes  : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC
Major Products : Control Panels & Distribution Boards : As per Customer Application
Major Products : Local Control Station : Ex d & WP ,WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Switch Socket  : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC Push button station & Rotary Switch  : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC
Major Products : Light Fittings  : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC
Major Products : Cable Glands & Accessories : Ex d & WP for Gas Group IIA/IIB & IIC
Major Products : Clean Room Fittings  : Ex d & WP for Gas Group IIA/IIB
Major Products : Mis. Items  : Telephone, Pressure switch, Electronic Hooter, Bell, Ex-d & WP respectively for Gas Group IIA/IIB  for Hooter : IIA/IIB & IIC , Torch : intrinsically Safe EEx ia for mining industry
Temperature Class T Class Ignition Temperature of the Mixture Permissible Surface Temperature of the Electrical Equipment T1 > 450° C 450° C T2 > 300 ...≤ 450° C 300° C T3 > 200 ...≤ 300° C 200° C T4 > 135 ...≤ 200° C 135° C T5 > 100 ...≤ 135° C 100° C T6 > 85 ...≤ 100° C 85° C
Gas group I Methane Gas group II A Ammonia, CO, Propane, Butane, Benzene, Acetone, Methanol Gas group II B Butadiene, Ethylene, Ethylene Oxide, Diethyl Ether Gas group II C Hydrogen Definition of Zone as per IS: 5572 Zone in which an explosive gas-air mixture is continuously  present or present for long period  Zone in which an explosive gas-air mixture is likely to occur in normal operation. Zone in which an explosive gas-air mixture is not likely to occur in normal operation and if occur it will exist only for a short time. Zone-0  : Zone-1  : Zone-2 :
Ingress Protection (IP) 1 st  Figure 2 nd  Figure Protection against solid bodies Protection against liquid bodies IP Tests IP Tests 0 No Protection 0 No Protection 1 Objects greater than 50mm 1 Vertically Dripping 2 Objects greater than 12mm 2 Angular Dripping 3 Objects greater than 2.5mm 3 Sprayed Water 4 Objects greater than 1.0mm 4 Splashed Water 5 Dust- Protected 5 Water Jets 6 Dust tight 6 Heavy Seas     7 Effects of immersion     8 Indefinite immersion Nema Type 3,3S & 13 4 & 4x 6 & 6P Equivalent IP IP54 IP56 IP 67 NEMA v/s IP Enclosure
STATUTORY REGULATIONS & APPROVALS CIMFR  (Central Institute of Mining and Fuel Research), Dhanbad, Jharkhand. Formerly :  CMRI  (Central Mining Research Institute) ERTL  (Electronics Regional Test Laboratory), Kolkata  PESO  (Petroleum and Safety Organization), Nagpur, Maharashtra. Formerly :  CCOE  (Chief Controller of Explosives) BIS  (Bureau Of Indian Standards)  DGMS  (Director General Mine Safety), Dhanbad, Jharkhand.
for, FCG Middle East Nandita Dev ( Sales & Marketing Manager )

Fcg Flameproof Middle East Nandita

  • 1.
    Author name Welcometo FCG Middle East FZC – An International branch of FCG Flameproof control gears Pvt.Ltd.- India
  • 2.
    Author name FlameproofEquipment : The protective enclosure to not become an ignition / explosion source to the flammable gases/vapors/liquids/fumes/dusts/fibers present in the Hazardous locations , which are explosive in nature while mixing with oxygen & lead to the explosion. An Electrical Equipment which requires to be a Flameproof, The Make & Break Contacts The Hot Surface Switching points Un organized cable harnessing Heavy Equipments running on Hi Ampere capacity When it can be an ignition source by coming in contact of oxygen, flammable Sources as said above , the ignition source are exemplified as :
  • 3.
    Explosion ONLY POSSIBLEAS PER BELOW EXPLANATION :
  • 4.
    Major Products :Junction Boxes : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Control Panels & Distribution Boards : As per Customer Application Local Control Station : Ex d & WP ,WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Switch Socket : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC Push button station & Rotary Switch : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC Light Fittings : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Control Gear Box : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Cable Glands & Accessories : Ex d & WP for Gas Group IIA/IIB & IIC Clean Room Fittings : Ex d & WP for Gas Group IIA/IIB Mis. Items : Telephone, Pressure switch, Electronic Hooter, Bell, Ex-d & WP respectively for Gas Group IIA/IIB for Hooter : IIA/IIB & IIC , Torch : intrinsically Safe EEx ia for mining industry
  • 5.
    Major Products :Junction Boxes : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC
  • 6.
    Major Products :Control Panels & Distribution Boards : As per Customer Application
  • 7.
    Major Products :Local Control Station : Ex d & WP ,WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC Switch Socket : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC Push button station & Rotary Switch : Ex d & WP , WP, Zone 1 & 2 , IIA/IIB & IIC
  • 8.
    Major Products :Light Fittings : Ex d & WP , Ex e & WP, Ex nr, Zone 1 & 2 , IIA/IIB & IIC
  • 9.
    Major Products :Cable Glands & Accessories : Ex d & WP for Gas Group IIA/IIB & IIC
  • 10.
    Major Products :Clean Room Fittings : Ex d & WP for Gas Group IIA/IIB
  • 11.
    Major Products :Mis. Items : Telephone, Pressure switch, Electronic Hooter, Bell, Ex-d & WP respectively for Gas Group IIA/IIB for Hooter : IIA/IIB & IIC , Torch : intrinsically Safe EEx ia for mining industry
  • 12.
    Temperature Class TClass Ignition Temperature of the Mixture Permissible Surface Temperature of the Electrical Equipment T1 > 450° C 450° C T2 > 300 ...≤ 450° C 300° C T3 > 200 ...≤ 300° C 200° C T4 > 135 ...≤ 200° C 135° C T5 > 100 ...≤ 135° C 100° C T6 > 85 ...≤ 100° C 85° C
  • 13.
    Gas group IMethane Gas group II A Ammonia, CO, Propane, Butane, Benzene, Acetone, Methanol Gas group II B Butadiene, Ethylene, Ethylene Oxide, Diethyl Ether Gas group II C Hydrogen Definition of Zone as per IS: 5572 Zone in which an explosive gas-air mixture is continuously present or present for long period Zone in which an explosive gas-air mixture is likely to occur in normal operation. Zone in which an explosive gas-air mixture is not likely to occur in normal operation and if occur it will exist only for a short time. Zone-0 : Zone-1 : Zone-2 :
  • 14.
    Ingress Protection (IP)1 st Figure 2 nd Figure Protection against solid bodies Protection against liquid bodies IP Tests IP Tests 0 No Protection 0 No Protection 1 Objects greater than 50mm 1 Vertically Dripping 2 Objects greater than 12mm 2 Angular Dripping 3 Objects greater than 2.5mm 3 Sprayed Water 4 Objects greater than 1.0mm 4 Splashed Water 5 Dust- Protected 5 Water Jets 6 Dust tight 6 Heavy Seas     7 Effects of immersion     8 Indefinite immersion Nema Type 3,3S & 13 4 & 4x 6 & 6P Equivalent IP IP54 IP56 IP 67 NEMA v/s IP Enclosure
  • 15.
    STATUTORY REGULATIONS &APPROVALS CIMFR (Central Institute of Mining and Fuel Research), Dhanbad, Jharkhand. Formerly : CMRI (Central Mining Research Institute) ERTL (Electronics Regional Test Laboratory), Kolkata PESO (Petroleum and Safety Organization), Nagpur, Maharashtra. Formerly : CCOE (Chief Controller of Explosives) BIS (Bureau Of Indian Standards) DGMS (Director General Mine Safety), Dhanbad, Jharkhand.
  • 16.
    for, FCG MiddleEast Nandita Dev ( Sales & Marketing Manager )