Theory of Time 2024 (Universal Theory for Everything)
EF Insulation Jackets
1. Enersol Flomar insulation jackets are
an effective method of saving energy
and reducing carbon emissions. By
simply fitting our insulation jackets to
your steam, condensate and hot water
systems, we can reduce your costs and
losses quickly and efficiently.
The payback in many cases is less than
one year, with jackets that are easy to fit
and can be removed without damage
for routine maintenance.
Site Survey and Report:
• A typical site survey in England is
in most cases free
• We identify all non-insulated pipe
and equipment
• A detailed survey report is then
issued listing costs and savings
Insulation Jacket Specifications:
• Constructed from high quality
materials with a “Class O” rating in
accordance with BS476 section 7
• Temperature range: 65°C to 250°C
• Double sided silicone coated
glass cloth
• Available from stock – with the ability
to make custom jackets quickly
• Tailored to fit the valve/flange ‘snugly’
whilst maintaining easy access
• They can reduce heat loss by as
much as 90%
INSULATION JACKETS
Flomar Limited, Marlborough Drive, Fleckney, Leicestershire LE8 8UR
sales@enersolcorp.com Tel: +44(0)116 240 3430 www.enersolflomar.com
EFIJ1
2. INSULATION JACKETS
BEFORE AFTER
This picture shows the rear of the boiler
before insulation.
This picture shows the rear of the boiler
after the completion of insulation.
ITEM QTY DESCRIPTION S.A. EACH 1. 2. 3. 4. 5. LOCATION
1 1
Boiler front 6
square meters
6.000 4234168.63 97307.60 4136861.03 £63.18 0.218352 Boiler number 1
2 1
Boiler back 2
square meters
2.000 1411389.54 32435.87 1378953.68 £21.06 0.072784 Boiler number 1
9 5 2̎'' Valves 0.170 486357.21 13785.24 472571.96 £7.22 0.024943 Feed water inlet
10 2 2̎'' Flanges 0.310 354754.67 10055.12 344699.55 £5.26 0.018194 Feed water inlet
16 1
Boiler front 6
square meters
6.000 4234168.63 97307.60 4136861.03 £63.18 0.218352 Boiler number 2
17 1
Boiler back 2
square meters
2.000 1411389.54 32435.87 1378953.68 £21.06 0.072784 Boiler number 2
55 2 1'' Valves 0.260 297536.17 8433.33 289102.85 £4.42 0.015259 Condensate
56 1 1'' Strainer valve 0.195 111576.07 3162.50 108413.57 £1.66 0.005722 Condensate
Savings Per Week = £187.04 0.646390
Savings Per Annum = £9,352.22 32.319520
Example Report
Quote Number: Report 001:
Key:
Area Boiler House Steam 8 Barg
1. Energyloss Uninsulated in Kj/Week.
2. Energyloss insulated in Kj/Week.
3. Kj saved per week after insulation.
Area Boiler House Steam 8 Barg
4. Savings per week at an energy cost of £30.00
per Tonne of Steam.
5. Estimated CO2 savings per week in tonnes.