| Metering Pumps | Process Instrumentation | Engineered Metering Systems |
DCM 5 Series Controller
A Recreational and Attraction Water Chemistry Solution
The ProMinent®
DCM 5 Series controller is the perfect partner for monitoring and controlling
water chemistry parameters and processes. The DCM 5 Series precision, flexibility and
uncompromising quality represent a world-class solution to ensure a safe and healthy water
experience for patrons.
Features & Benefits
•• Proprietary sensor technology
•• Oxidant specific sensor
•• Combined chlorine control1
•• Simultaneous Chlorine/ORP control
•• Eco! mode
•• VFD control (optional)
•• Real-time corrosion & calcification monitoring and alarm2
•• Loading compensation via true proportional control
•• Hydraulically advanced flowcell assembly
•• Automatic discrete control and flow adjustments of
chemical dosing pump3
•• Capable of controlling two bodies of water4
•• Trackster™ auto poll, data logging, graphing and report
building software
•• Standard web-based real-time monitor and control via
network-enabled PC, smart phone, iPad or tablet device
Applications
•• Swimming pools, Therapy pools & Hot tubs
•• Water parks & Splash pads
•• Amusement Park Attractions, Zoos & Aquariums
Ordering Information
•• DCM 500 - Controller package for pH, ORP and
Temp (P/N: 7761461)
•• DCM 501 - Controller package for pH, ORP and
PPM on non-stabilized (CYA) water (P/N: 7761462)
•• DCM 502 - Controller package for pH, ORP, PPM
and Combined PPM on non-stabilized (CYA) water
(P/N: 7761463)
•• DCM 503 - Controller package for pH, ORP and
PPM with CYA stabilized water (P/N: 7761464)
Notes:
1 Requires optional total chlorine probe
2 Requires optional corrosion and scaling probes
3 When used with ProMinent dosing pumps
4 Optional
ProMinent Fluid Controls, Inc.
136 Industry Drive • Pittsburgh, PA 15275 USA
(412) 787-2484 • Fax: (412) 787-0704
email: sales@prominent.us • www.prominent.us
Specifications Details
Remote Fully interactive Ethernet TCP/IP graphical interface with security access codes
Local 2 line, 12 character LCD display, 5 buttons, 2 LEDs: Steady Blue = "OK", Flashing Red = "Alarm"
Included Sensors pH, ORP, Temperature
Optional Sensors
Field Upgrades Sensor input modules are available for field upgrades.
Digital Inputs 8, (7 fully configurable)
8 (configurable options)
Control Relays 5 (fully assignable) for:
1. Acid 5. Filter Aid / Flow switch test & verify
2. Oxidant 6.	
  Auto	
  Fill
3. Chlorine Boost / Caustic Feed 7.	
  Heater	
  Control
4. Probe Wash / Alarm 8.	
  UV	
  Control
(Interlocked with sample and recirc flow when used for chemical feed.)
Digital Outputs
1. UV
2. Pump / VFD Control
3. Chlorine / Ozone Generator
4. Alarm / Eco! Mode mode for Recirc Pump
Base feed available if sensor disconnected
Analog Outputs 2 (optional isolated, 4-20mA)
On/Off Chlorine Boost / Ozone Control
ORP assisting Residual Flow Restored delay (adjustable)
P/PI/PID Emergency Off for Recirculation Pump
Eco! Mode Autofill
Event Timers Chem Feed Verification (optional)
UV Boost / VFD Control Pulsed Pump Speed
HTML server on board (standard)
HTML, Micro Web Server with DHCP or user definable IP address
Local and remote access protected by access codes
Power 120 or 230 VAC, 60/50 Hz, 5A/3A, single phase only
Fusing 5 amps @ 120 VAC or 2.5 Amps @ 230 VAC
Surge Suppression Relay 2-5 N.O. contacts snubbed @ 0.1 uF, 150 ohm
Accessory Power 15-22 VDC, Unregulated, Thermally Fused @ 50 mA
Enclosure Non-metallic, NEMA 4X, 14" x 9" x 4.5" (WxHxD)
Convenience Save and restore of "last known good" parameters
Multiple pre-loaded configurations and browser views
5 years on electronics
2 years on ORP, pH sensors
1 year on all other parts
Operator Interface
Sensors
Inputs
System
Warranty
Free Chlorine, Total Chlorine, Calculated Combined Chlorine, Salt Generated Free Chlorine, Stabilized Chlorine,
Conductivity, Bromine, Feed Verification, Corrosion, Calcification, Flow Rate, Water Level. Second body of water set of
sensors: pH + ORP, Temperature
Example: 2 Cond, 2 Temp, 1 pH, 1 ORP, 1 FAC, 1 TRC
4 (fully assignable as dry contact sets or variable frequency pump) for:
10Base T, TCP/IP Ethernet, Optional Wireless EVDO Cellular, Smartphone / iPad
Communication
Analog Inputs
Outputs
Control
Security
PN: 7750501
DCM_5.indd rev2 03/11/2013
DCM 5 Series Controller
Specifications
© 2013 ProMinent Fluid Controls, Inc. All Rights Reserved.

More Related Content

What's hot

Cl8 datasheet
Cl8 datasheetCl8 datasheet
Cl8 datasheet
a1-cbiss
 
LynxBrochure2016_rev1
LynxBrochure2016_rev1LynxBrochure2016_rev1
LynxBrochure2016_rev1
Vinnie Nijor
 
Itron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - englishItron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - english
Thorne & Derrick UK
 
Itron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - EnglishItron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - English
Thorne & Derrick UK
 

What's hot (20)

Multifunction Gateways - QEI LLC
Multifunction Gateways - QEI LLCMultifunction Gateways - QEI LLC
Multifunction Gateways - QEI LLC
 
QEI LLC
QEI LLCQEI LLC
QEI LLC
 
SCAIME eNod4: weighing controllers range for process automation
SCAIME eNod4: weighing controllers range for process automationSCAIME eNod4: weighing controllers range for process automation
SCAIME eNod4: weighing controllers range for process automation
 
Serinus 57-trs-analyser
Serinus 57-trs-analyserSerinus 57-trs-analyser
Serinus 57-trs-analyser
 
Lab equip list
Lab equip listLab equip list
Lab equip list
 
Cl8 datasheet
Cl8 datasheetCl8 datasheet
Cl8 datasheet
 
SCAIME - Digital load cells for packaging machines
SCAIME - Digital load cells for packaging machinesSCAIME - Digital load cells for packaging machines
SCAIME - Digital load cells for packaging machines
 
LynxBrochure2016_rev1
LynxBrochure2016_rev1LynxBrochure2016_rev1
LynxBrochure2016_rev1
 
Introducing the West Range of Products
Introducing the West Range of ProductsIntroducing the West Range of Products
Introducing the West Range of Products
 
pH.ORP Transmitter-Analog and digital glass
pH.ORP Transmitter-Analog and digital glasspH.ORP Transmitter-Analog and digital glass
pH.ORP Transmitter-Analog and digital glass
 
Signal Fire Wireless Telemetry Catalog
Signal Fire Wireless Telemetry CatalogSignal Fire Wireless Telemetry Catalog
Signal Fire Wireless Telemetry Catalog
 
MC9RS08KA8/4 Introduction
MC9RS08KA8/4 IntroductionMC9RS08KA8/4 Introduction
MC9RS08KA8/4 Introduction
 
Drager Regard 3900 Fixed Gas Detector Control System - Spec Sheet
Drager Regard 3900 Fixed Gas Detector Control System - Spec SheetDrager Regard 3900 Fixed Gas Detector Control System - Spec Sheet
Drager Regard 3900 Fixed Gas Detector Control System - Spec Sheet
 
Itron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - englishItron cf ultra maxx v heat meter system - brochure - english
Itron cf ultra maxx v heat meter system - brochure - english
 
Thermal Mass Flow Meter for Oil & Gas Applications
Thermal Mass Flow Meter for Oil & Gas ApplicationsThermal Mass Flow Meter for Oil & Gas Applications
Thermal Mass Flow Meter for Oil & Gas Applications
 
Total Chlorine Analyzer System
Total Chlorine Analyzer SystemTotal Chlorine Analyzer System
Total Chlorine Analyzer System
 
ITRON WATER SYSTEMS
ITRON WATER SYSTEMSITRON WATER SYSTEMS
ITRON WATER SYSTEMS
 
PREPARATION OF C&I CABLE SCHEDULES FOR DCS PANELS
PREPARATION OF C&I CABLE SCHEDULES FOR DCS PANELSPREPARATION OF C&I CABLE SCHEDULES FOR DCS PANELS
PREPARATION OF C&I CABLE SCHEDULES FOR DCS PANELS
 
Controlador ORP Milton Roy
Controlador ORP Milton RoyControlador ORP Milton Roy
Controlador ORP Milton Roy
 
Itron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - EnglishItron CF55 Heat Meter - Brochure - English
Itron CF55 Heat Meter - Brochure - English
 

Viewers also liked

ICF Membership Certificate
ICF Membership CertificateICF Membership Certificate
ICF Membership Certificate
Daniel Godoy
 
Cover Letter Final Draft
Cover Letter Final DraftCover Letter Final Draft
Cover Letter Final Draft
Carly Avey
 
Aplikasi stoikiometri tugas ii
Aplikasi stoikiometri tugas iiAplikasi stoikiometri tugas ii
Aplikasi stoikiometri tugas ii
yahyakurnia23
 

Viewers also liked (14)

Ik ki jardueren ondorioak
Ik ki jardueren ondorioakIk ki jardueren ondorioak
Ik ki jardueren ondorioak
 
Animais
Animais Animais
Animais
 
ICF Membership Certificate
ICF Membership CertificateICF Membership Certificate
ICF Membership Certificate
 
20 sijil penyertaan
20 sijil penyertaan20 sijil penyertaan
20 sijil penyertaan
 
Reversible image data hiding with contrast enhancement
Reversible image data hiding with contrast enhancementReversible image data hiding with contrast enhancement
Reversible image data hiding with contrast enhancement
 
Trabajoclase
TrabajoclaseTrabajoclase
Trabajoclase
 
Praia do Porto Santo
Praia do Porto SantoPraia do Porto Santo
Praia do Porto Santo
 
Modul 3 - Oppgave 2
Modul 3 - Oppgave 2Modul 3 - Oppgave 2
Modul 3 - Oppgave 2
 
Cover Letter Final Draft
Cover Letter Final DraftCover Letter Final Draft
Cover Letter Final Draft
 
Veeam presentación evento prensa Argentina
Veeam presentación evento prensa ArgentinaVeeam presentación evento prensa Argentina
Veeam presentación evento prensa Argentina
 
Aplikasi stoikiometri tugas ii
Aplikasi stoikiometri tugas iiAplikasi stoikiometri tugas ii
Aplikasi stoikiometri tugas ii
 
Construction equipments and methods
Construction equipments and methodsConstruction equipments and methods
Construction equipments and methods
 
Aντιγόνη του Σοφοκλή -Εισαγωγή
Aντιγόνη του Σοφοκλή -ΕισαγωγήAντιγόνη του Σοφοκλή -Εισαγωγή
Aντιγόνη του Σοφοκλή -Εισαγωγή
 
ман-2015
ман-2015ман-2015
ман-2015
 

Similar to dcm_5 cut sheet 7761461 7761462 7761463 7761464

Monicon brochure
Monicon brochureMonicon brochure
Monicon brochure
a1-cbiss
 

Similar to dcm_5 cut sheet 7761461 7761462 7761463 7761464 (20)

ATI-Q46H-79PR-Total-Chlorine-Monitor.pdf
ATI-Q46H-79PR-Total-Chlorine-Monitor.pdfATI-Q46H-79PR-Total-Chlorine-Monitor.pdf
ATI-Q46H-79PR-Total-Chlorine-Monitor.pdf
 
ATIs-Q46H-Residual-Chlorine-Monitor.pdf
ATIs-Q46H-Residual-Chlorine-Monitor.pdfATIs-Q46H-Residual-Chlorine-Monitor.pdf
ATIs-Q46H-Residual-Chlorine-Monitor.pdf
 
ATi_Product Brochure.pdf
ATi_Product Brochure.pdfATi_Product Brochure.pdf
ATi_Product Brochure.pdf
 
Double-Vessel-Fermenter-System.pdf......
Double-Vessel-Fermenter-System.pdf......Double-Vessel-Fermenter-System.pdf......
Double-Vessel-Fermenter-System.pdf......
 
Bioreactor
BioreactorBioreactor
Bioreactor
 
Introducing the West Range
Introducing the West RangeIntroducing the West Range
Introducing the West Range
 
Ecotech exactus-bam-spec-sheet-20180702
Ecotech exactus-bam-spec-sheet-20180702Ecotech exactus-bam-spec-sheet-20180702
Ecotech exactus-bam-spec-sheet-20180702
 
Introducing: Advanced Water Monitoring & Control Innovation for Industrial, M...
Introducing: Advanced Water Monitoring & Control Innovation for Industrial, M...Introducing: Advanced Water Monitoring & Control Innovation for Industrial, M...
Introducing: Advanced Water Monitoring & Control Innovation for Industrial, M...
 
Dynasonics i sonic 4000 datasheet badger meter_open-channel flow meter
Dynasonics i sonic 4000 datasheet badger meter_open-channel flow meterDynasonics i sonic 4000 datasheet badger meter_open-channel flow meter
Dynasonics i sonic 4000 datasheet badger meter_open-channel flow meter
 
Siemens sitrans LUT400 series
Siemens sitrans LUT400 seriesSiemens sitrans LUT400 series
Siemens sitrans LUT400 series
 
Culligan G series RO
Culligan G series ROCulligan G series RO
Culligan G series RO
 
Monicon brochure
Monicon brochureMonicon brochure
Monicon brochure
 
12 - SYSTEA presentation at Hydro-meteorological instrumentation workshop-Sep-15
12 - SYSTEA presentation at Hydro-meteorological instrumentation workshop-Sep-1512 - SYSTEA presentation at Hydro-meteorological instrumentation workshop-Sep-15
12 - SYSTEA presentation at Hydro-meteorological instrumentation workshop-Sep-15
 
pH/redox Transmitter
pH/redox TransmitterpH/redox Transmitter
pH/redox Transmitter
 
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
 
Topaz brochure uk-2016-al
Topaz brochure uk-2016-alTopaz brochure uk-2016-al
Topaz brochure uk-2016-al
 
ATI-Q46F.pdf
ATI-Q46F.pdfATI-Q46F.pdf
ATI-Q46F.pdf
 
Classic Controls Caribbean North Linecard
Classic Controls Caribbean North LinecardClassic Controls Caribbean North Linecard
Classic Controls Caribbean North Linecard
 
ATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdf
ATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdfATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdf
ATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdf
 
R501 ADVANCED TRANSFORMER MONITOR | Rugged Monitoring
R501 ADVANCED TRANSFORMER MONITOR | Rugged MonitoringR501 ADVANCED TRANSFORMER MONITOR | Rugged Monitoring
R501 ADVANCED TRANSFORMER MONITOR | Rugged Monitoring
 

dcm_5 cut sheet 7761461 7761462 7761463 7761464

  • 1. | Metering Pumps | Process Instrumentation | Engineered Metering Systems | DCM 5 Series Controller A Recreational and Attraction Water Chemistry Solution The ProMinent® DCM 5 Series controller is the perfect partner for monitoring and controlling water chemistry parameters and processes. The DCM 5 Series precision, flexibility and uncompromising quality represent a world-class solution to ensure a safe and healthy water experience for patrons. Features & Benefits •• Proprietary sensor technology •• Oxidant specific sensor •• Combined chlorine control1 •• Simultaneous Chlorine/ORP control •• Eco! mode •• VFD control (optional) •• Real-time corrosion & calcification monitoring and alarm2 •• Loading compensation via true proportional control •• Hydraulically advanced flowcell assembly •• Automatic discrete control and flow adjustments of chemical dosing pump3 •• Capable of controlling two bodies of water4 •• Trackster™ auto poll, data logging, graphing and report building software •• Standard web-based real-time monitor and control via network-enabled PC, smart phone, iPad or tablet device Applications •• Swimming pools, Therapy pools & Hot tubs •• Water parks & Splash pads •• Amusement Park Attractions, Zoos & Aquariums Ordering Information •• DCM 500 - Controller package for pH, ORP and Temp (P/N: 7761461) •• DCM 501 - Controller package for pH, ORP and PPM on non-stabilized (CYA) water (P/N: 7761462) •• DCM 502 - Controller package for pH, ORP, PPM and Combined PPM on non-stabilized (CYA) water (P/N: 7761463) •• DCM 503 - Controller package for pH, ORP and PPM with CYA stabilized water (P/N: 7761464) Notes: 1 Requires optional total chlorine probe 2 Requires optional corrosion and scaling probes 3 When used with ProMinent dosing pumps 4 Optional
  • 2. ProMinent Fluid Controls, Inc. 136 Industry Drive • Pittsburgh, PA 15275 USA (412) 787-2484 • Fax: (412) 787-0704 email: sales@prominent.us • www.prominent.us Specifications Details Remote Fully interactive Ethernet TCP/IP graphical interface with security access codes Local 2 line, 12 character LCD display, 5 buttons, 2 LEDs: Steady Blue = "OK", Flashing Red = "Alarm" Included Sensors pH, ORP, Temperature Optional Sensors Field Upgrades Sensor input modules are available for field upgrades. Digital Inputs 8, (7 fully configurable) 8 (configurable options) Control Relays 5 (fully assignable) for: 1. Acid 5. Filter Aid / Flow switch test & verify 2. Oxidant 6.  Auto  Fill 3. Chlorine Boost / Caustic Feed 7.  Heater  Control 4. Probe Wash / Alarm 8.  UV  Control (Interlocked with sample and recirc flow when used for chemical feed.) Digital Outputs 1. UV 2. Pump / VFD Control 3. Chlorine / Ozone Generator 4. Alarm / Eco! Mode mode for Recirc Pump Base feed available if sensor disconnected Analog Outputs 2 (optional isolated, 4-20mA) On/Off Chlorine Boost / Ozone Control ORP assisting Residual Flow Restored delay (adjustable) P/PI/PID Emergency Off for Recirculation Pump Eco! Mode Autofill Event Timers Chem Feed Verification (optional) UV Boost / VFD Control Pulsed Pump Speed HTML server on board (standard) HTML, Micro Web Server with DHCP or user definable IP address Local and remote access protected by access codes Power 120 or 230 VAC, 60/50 Hz, 5A/3A, single phase only Fusing 5 amps @ 120 VAC or 2.5 Amps @ 230 VAC Surge Suppression Relay 2-5 N.O. contacts snubbed @ 0.1 uF, 150 ohm Accessory Power 15-22 VDC, Unregulated, Thermally Fused @ 50 mA Enclosure Non-metallic, NEMA 4X, 14" x 9" x 4.5" (WxHxD) Convenience Save and restore of "last known good" parameters Multiple pre-loaded configurations and browser views 5 years on electronics 2 years on ORP, pH sensors 1 year on all other parts Operator Interface Sensors Inputs System Warranty Free Chlorine, Total Chlorine, Calculated Combined Chlorine, Salt Generated Free Chlorine, Stabilized Chlorine, Conductivity, Bromine, Feed Verification, Corrosion, Calcification, Flow Rate, Water Level. Second body of water set of sensors: pH + ORP, Temperature Example: 2 Cond, 2 Temp, 1 pH, 1 ORP, 1 FAC, 1 TRC 4 (fully assignable as dry contact sets or variable frequency pump) for: 10Base T, TCP/IP Ethernet, Optional Wireless EVDO Cellular, Smartphone / iPad Communication Analog Inputs Outputs Control Security PN: 7750501 DCM_5.indd rev2 03/11/2013 DCM 5 Series Controller Specifications © 2013 ProMinent Fluid Controls, Inc. All Rights Reserved.