SlideShare a Scribd company logo
1 of 2
Download to read offline
3-447-018-03
1/5.18
GMC-I Messtechnik GmbH
METRALINE RLOCHECK
Digital Low-Resistance Meter per EN 61557-4
Applications
The METRALINE RLO-CHECK is a test instrument for checking
the continuity of protective conductors and equipotential bonding. 
With the help of the acoustic and luminous signals generated by
the test instrument, the user determines whether or not the conti-
nuity of the protective conductor and equipotential bonding has
an electrical resistance of no greater than 1 .
Measurement can be alternatively conducted between two input
sockets instead of between a measuring instrument input socket
and the cable reel output.
Features
Interference Voltage Detection
If interference voltage is detected at the respective protective con-
ductor, resistance measurement is disabled. An intermittent
acoustic signal is generated, the color of the display is changed to
red and interference voltage is displayed as an RMS value. Input
impedance: 300 k, warning range: 8 V~/DC to 400 V~/DC.
Balancing and Calibration
The measuring instrument can be balanced to 0  with the help
of the short-circuit shunt.
The threshold for the continuity test can be balanced to 1  with
the help of the calibration shunt.
Applicable Regulations and Standards
IEC 61010-1/-031 
DIN EN 61010-1/-031 
VDE 0411-1/-031
Safety requirements for electrical equipment for 
measurement, control and laboratory use
Part 1: General requirements
Part 31: Safety requirements for hand-held probe 
assemblies for electrical measurement and test
DIN EN 61557-1 
VDE 0413-1
Electrical safety in low voltage distribution systems up 
to 1000 V AC and 1500 V DC – Equipment for testing,
measuring or monitoring of protective measures
Part 1: General requirements
DIN EN 61557-4 
VDE 0413-4
Part 4: Resistance of earth connection and 
equipotential bonding
IEC 61326-1
DIN EN 61326-1
Electrical equipment for measurement, control and 
laboratory use – EMC requirements
Part 1: General requirements
DIN EN 60529
VDE 0470-1
Degrees of protection provided by enclosures (IP code)
• Cable reel with 30 m cable
• Contact resistance measurement, 
measuring range: 0.00  ... 20.0 
• Acoustic signaling for continuity (R < 1 )
• Acoustic and optical indication of interference voltage 
detection
• Interference voltage display: 8 ... 400 V
• Automatic polarity reversal per DIN EN 61557-4/VDE 0413-4
• Balancing function for cable reel and accessories 
(compensation for up to 4 )
• Test certificate
• Extensive accessories
Edited in Germany • Subject to change without notice • PDF version available on the Internet
METRALINE RLOCHECK
Digital Low-Resistance Meter per EN 61557-4
GMC-I Messtechnik GmbH 
Südwestpark 15 
90449 Nürnberg • Germany
Phone: +49-911-8602-111
Fax: +49 911 8602-777
e-mail: info@gossenmetrawatt.com
www.gossenmetrawatt.com
Characteristic Values
Contact Resistance Measurement
Range () Resolution
()
Measuring Uncertainty
0.00 ... 0.49 0.01 0.07 
0.50 ... 1.99 0.01 (10% rdg.+0.02 )
2.00 ... 9.99 0.01
8% rdg.
10.0 ... 20.0 0.1
Measuring voltage: 4 ... 6 V, automatic polarity reversal per
DIN EN 61557-4/VDE 0413-4
Measuring current: 200 mA ... 210 mA
Key
rdg. = reading
Ambient Conditions
Operating Conditions
Operating temperature -20 ... 55 C
Relative humidity max. 80% for temperatures of up to 31 C,
linear decrease in relative humidity down to
50% at 40 C, no condensation allowed
Storage Conditions
Temperature -20 ... 55 C
Electrical Safety
Measuring category With attached test probe cap: 
CAT III 600 V / CAT IV 300 V
Pollution degree 2
Protection category II
Fuse link 500 mA, 6.3 mm x 32 mm, 
breaking capacity: 30 kA at 690 V
Maximum current in 
cable during use as 
cable reeling device 0.5 A (protected by fuse)
Electromagnetic Compatibility (EMC)
Interference emission EN 61326-1:2013 class B
Interference immunity EN 61326-1:2013
Mechanical Design
Weight 1.3 kg with hip belt
Dimensions Drum diameter: 18 cm, height: 12 cm
Power Supply
Batteries 4 ea. AA battery, 1.5 V alkaline 
or 1.2 V NIMH (with at least 750 mAh)
(Rechargeable AA batteries can be used but
they reduce the period of use).
Period of use Approx. 1.7 days under normal conditions
of use at 20 C with new batteries.
Approx. 5 hours and 50 minutes for con-
tinuous measurement of the contact resis-
tance of an earthing conductor at less than
1  with activated acoustic signal and new
batteries.
Battery indicator Battery capacity display via battery symbol
Power OFF function The meter is switched off automatically
after five minutes of nonuse.
Scope of Delivery
1 Measuring instrument
4 Batteries (AA)
1 Hip belt
1 Cable reel with 30 m cable
1 Test probe with protective cap
1 Alligator clip
1 Coil cable (test cable)
1 PE adapter for electric outlets
1 Short-circuit shunt (0 )
1 Calibration shunt for continuity threshold (1 )
1 Set of operating instructions
1 Test certificate
Order Information
Description Type Article Number
Digital low-resistance measuring 
instrument per DIN EN 61557-4 /
VDE 0413-4 with cable reel and
30 m cable for measuring the resis-
tance of protective conductors and
equipotential bonding
METRALINE RLO-
CHECK M630W
Telescoping rod for RLO and RINS
measurements, CAT III 600 V / CAT
IV 300 V, 1 A, retracted: 53.5 cm,
extended: 120 cm, 190 g
TELEARM 120 D)
Z505C
Telescoping rod for RLO and RINS
measurements, CAT III 600 V / CAT
IV 300 V, 1 A, retracted: 73.5 cm,
extended: 180 cm, 250 g
TELEARM 180 D)
Z505D
D
Data sheet available

More Related Content

What's hot

Chapter 3 automation devices
Chapter 3  automation devicesChapter 3  automation devices
Chapter 3 automation devices
Mohamad Sahiedan
 
Teklinx Testing Equipment
Teklinx Testing EquipmentTeklinx Testing Equipment
Teklinx Testing Equipment
Rizwan Buttar
 
Wilcoxon - Accelerometer Electronic Basics
Wilcoxon - Accelerometer Electronic BasicsWilcoxon - Accelerometer Electronic Basics
Wilcoxon - Accelerometer Electronic Basics
TALONTechSales
 

What's hot (20)

Chapter 3 automation devices
Chapter 3  automation devicesChapter 3  automation devices
Chapter 3 automation devices
 
Basicelectricalmeasuringinstruments 160111044802
Basicelectricalmeasuringinstruments 160111044802Basicelectricalmeasuringinstruments 160111044802
Basicelectricalmeasuringinstruments 160111044802
 
Fluke Electrical Safety Seminar Slides
Fluke Electrical Safety Seminar SlidesFluke Electrical Safety Seminar Slides
Fluke Electrical Safety Seminar Slides
 
Teklinx Testing Equipment
Teklinx Testing EquipmentTeklinx Testing Equipment
Teklinx Testing Equipment
 
Current Sensor
Current SensorCurrent Sensor
Current Sensor
 
Datasheet Fluke Electrical Power Standard. Hubungi PT. Siwali Swantika 021-45...
Datasheet Fluke Electrical Power Standard. Hubungi PT. Siwali Swantika 021-45...Datasheet Fluke Electrical Power Standard. Hubungi PT. Siwali Swantika 021-45...
Datasheet Fluke Electrical Power Standard. Hubungi PT. Siwali Swantika 021-45...
 
Insulation tester
Insulation testerInsulation tester
Insulation tester
 
Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618
 
Brosur Fluke 289
Brosur Fluke 289 Brosur Fluke 289
Brosur Fluke 289
 
EMI Unit II
EMI Unit IIEMI Unit II
EMI Unit II
 
Brosur Fluke Insulation Resistance Testing. Hubungi PT. Siwali Swantika 021-4...
Brosur Fluke Insulation Resistance Testing. Hubungi PT. Siwali Swantika 021-4...Brosur Fluke Insulation Resistance Testing. Hubungi PT. Siwali Swantika 021-4...
Brosur Fluke Insulation Resistance Testing. Hubungi PT. Siwali Swantika 021-4...
 
The megger 514440
The megger 514440The megger 514440
The megger 514440
 
TESCO Tuesday: Communication Equipment
TESCO Tuesday: Communication EquipmentTESCO Tuesday: Communication Equipment
TESCO Tuesday: Communication Equipment
 
Sensors for Biomedical Devices and systems
Sensors for Biomedical Devices and systemsSensors for Biomedical Devices and systems
Sensors for Biomedical Devices and systems
 
Wilcoxon - Accelerometer Electronic Basics
Wilcoxon - Accelerometer Electronic BasicsWilcoxon - Accelerometer Electronic Basics
Wilcoxon - Accelerometer Electronic Basics
 
Hallikainen Opacity monitor
Hallikainen Opacity monitorHallikainen Opacity monitor
Hallikainen Opacity monitor
 
BR-High-Power-Test-Lab-Brochure
BR-High-Power-Test-Lab-BrochureBR-High-Power-Test-Lab-Brochure
BR-High-Power-Test-Lab-Brochure
 
FTW325
FTW325FTW325
FTW325
 
POWER ANALYZER HIOKI PW3390 - Instrumentos de Medida S.L.
POWER ANALYZER HIOKI PW3390 - Instrumentos de Medida S.L.POWER ANALYZER HIOKI PW3390 - Instrumentos de Medida S.L.
POWER ANALYZER HIOKI PW3390 - Instrumentos de Medida S.L.
 
Calmet testing energy-measurement-equipment
Calmet testing energy-measurement-equipmentCalmet testing energy-measurement-equipment
Calmet testing energy-measurement-equipment
 

Similar to Data Teknis Gossen Metrawatt Low Resistance Meter

Similar to Data Teknis Gossen Metrawatt Low Resistance Meter (20)

Data Teknis Gossen Metrawatt Insulation Tester METRISO PRO
Data Teknis Gossen Metrawatt Insulation Tester METRISO PROData Teknis Gossen Metrawatt Insulation Tester METRISO PRO
Data Teknis Gossen Metrawatt Insulation Tester METRISO PRO
 
Data Teknis Gossen Metrawatt Multimeter : METRAport 3A
Data Teknis Gossen Metrawatt Multimeter : METRAport 3AData Teknis Gossen Metrawatt Multimeter : METRAport 3A
Data Teknis Gossen Metrawatt Multimeter : METRAport 3A
 
Data Teknis Gossen Metrawatt Multimeter : METRAHIT ISO & METRAHIT COIL
Data Teknis Gossen Metrawatt Multimeter : METRAHIT ISO & METRAHIT COILData Teknis Gossen Metrawatt Multimeter : METRAHIT ISO & METRAHIT COIL
Data Teknis Gossen Metrawatt Multimeter : METRAHIT ISO & METRAHIT COIL
 
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTHData Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
Data Teknis Gossen Metrawatt Earth Ground Clamp : METRACLIP EARTH
 
Data Teknis Gossen Metrawatt Multimeter : METRAHIT T-COM PLUS
Data Teknis Gossen Metrawatt Multimeter : METRAHIT T-COM PLUSData Teknis Gossen Metrawatt Multimeter : METRAHIT T-COM PLUS
Data Teknis Gossen Metrawatt Multimeter : METRAHIT T-COM PLUS
 
Data Teknis Gossen Metrawatt : PROFITEST EMOBILITY
Data Teknis Gossen Metrawatt : PROFITEST EMOBILITYData Teknis Gossen Metrawatt : PROFITEST EMOBILITY
Data Teknis Gossen Metrawatt : PROFITEST EMOBILITY
 
Datasheet Metrel MI 3250. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Metrel MI 3250. Hubungi PT. Siwali Swantika 021-45850618Datasheet Metrel MI 3250. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Metrel MI 3250. Hubungi PT. Siwali Swantika 021-45850618
 
Data Teknis Gossen Metrawatt Battery Tester : METRACELL - BT PRO
Data Teknis Gossen Metrawatt Battery Tester : METRACELL - BT PROData Teknis Gossen Metrawatt Battery Tester : METRACELL - BT PRO
Data Teknis Gossen Metrawatt Battery Tester : METRACELL - BT PRO
 
Data Teknis Gossen Metrawatt Insulation Tester : METRISO PRIME 10
Data Teknis Gossen Metrawatt Insulation Tester : METRISO PRIME 10Data Teknis Gossen Metrawatt Insulation Tester : METRISO PRIME 10
Data Teknis Gossen Metrawatt Insulation Tester : METRISO PRIME 10
 
Data Teknis Gossen Metrawatt Insulation Tester METRISO 1000A
Data Teknis Gossen Metrawatt Insulation Tester METRISO 1000AData Teknis Gossen Metrawatt Insulation Tester METRISO 1000A
Data Teknis Gossen Metrawatt Insulation Tester METRISO 1000A
 
Seaward Catalog High Voltage Test Tools
Seaward Catalog High Voltage Test ToolsSeaward Catalog High Voltage Test Tools
Seaward Catalog High Voltage Test Tools
 
Data Teknis Gossen Metrawatt Ground Tester : GEOHM 5
Data Teknis Gossen Metrawatt Ground Tester : GEOHM 5Data Teknis Gossen Metrawatt Ground Tester : GEOHM 5
Data Teknis Gossen Metrawatt Ground Tester : GEOHM 5
 
CATU C Diag Touch Continuity Tester
CATU C Diag Touch Continuity TesterCATU C Diag Touch Continuity Tester
CATU C Diag Touch Continuity Tester
 
Seaward KD1E High Voltage HV Indicators & Detectors, Phasing Units, Ammeters ...
Seaward KD1E High Voltage HV Indicators & Detectors, Phasing Units, Ammeters ...Seaward KD1E High Voltage HV Indicators & Detectors, Phasing Units, Ammeters ...
Seaward KD1E High Voltage HV Indicators & Detectors, Phasing Units, Ammeters ...
 
METRISO 1000A Insulation Tester
METRISO 1000A Insulation TesterMETRISO 1000A Insulation Tester
METRISO 1000A Insulation Tester
 
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
Data Teknis Gossen Metrawatt Insulation Tester METRISO INTRO-METRISO BASE-MET...
 
MIC-5005 & MIC - 5010
MIC-5005 & MIC - 5010MIC-5005 & MIC - 5010
MIC-5005 & MIC - 5010
 
Data Teknis Gossen Metrawatt Multimeter METRAHIT : PM TECH, PM XTRA, EBASE, E...
Data Teknis Gossen Metrawatt Multimeter METRAHIT : PM TECH, PM XTRA, EBASE, E...Data Teknis Gossen Metrawatt Multimeter METRAHIT : PM TECH, PM XTRA, EBASE, E...
Data Teknis Gossen Metrawatt Multimeter METRAHIT : PM TECH, PM XTRA, EBASE, E...
 
AC Line Filtering
AC Line FilteringAC Line Filtering
AC Line Filtering
 
Datasheet Fluke 1621. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 1621. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 1621. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 1621. Hubungi PT. Siwali Swantika 021-45850618
 

More from PT. Siwali Swantika

More from PT. Siwali Swantika (20)

NetAlly LinkRunner 10G
NetAlly LinkRunner 10GNetAlly LinkRunner 10G
NetAlly LinkRunner 10G
 
NetAlly Etherscope nXG
NetAlly Etherscope nXGNetAlly Etherscope nXG
NetAlly Etherscope nXG
 
Fluke 418x Infrared Calibrator.pdf
Fluke 418x Infrared Calibrator.pdfFluke 418x Infrared Calibrator.pdf
Fluke 418x Infrared Calibrator.pdf
 
Kalibrasi dengan metode komparasi
Kalibrasi dengan metode komparasiKalibrasi dengan metode komparasi
Kalibrasi dengan metode komparasi
 
Kalibrasi Transmitter
Kalibrasi TransmitterKalibrasi Transmitter
Kalibrasi Transmitter
 
Kategori Pengukuran Kelistrikan
Kategori Pengukuran KelistrikanKategori Pengukuran Kelistrikan
Kategori Pengukuran Kelistrikan
 
5 Langkah Kalibrasi RTD
5 Langkah Kalibrasi RTD5 Langkah Kalibrasi RTD
5 Langkah Kalibrasi RTD
 
Keuntungan AnyWare Cloud.pdf
Keuntungan AnyWare Cloud.pdfKeuntungan AnyWare Cloud.pdf
Keuntungan AnyWare Cloud.pdf
 
3 Metode Kalibrasi Sensor Suhu
3 Metode Kalibrasi Sensor Suhu3 Metode Kalibrasi Sensor Suhu
3 Metode Kalibrasi Sensor Suhu
 
10 Langkah Kalibrasi Termometer.pdf
10 Langkah Kalibrasi Termometer.pdf10 Langkah Kalibrasi Termometer.pdf
10 Langkah Kalibrasi Termometer.pdf
 
Pengujian Sistem Photovoltaic.pdf
Pengujian Sistem Photovoltaic.pdfPengujian Sistem Photovoltaic.pdf
Pengujian Sistem Photovoltaic.pdf
 
Fluke Process Calibration Tools Catalog
Fluke Process Calibration Tools CatalogFluke Process Calibration Tools Catalog
Fluke Process Calibration Tools Catalog
 
Fluke Temperature Calibration Catalog
Fluke Temperature Calibration CatalogFluke Temperature Calibration Catalog
Fluke Temperature Calibration Catalog
 
Vitrek Catalog
Vitrek CatalogVitrek Catalog
Vitrek Catalog
 
Rotronic Water Activity Series
Rotronic Water Activity SeriesRotronic Water Activity Series
Rotronic Water Activity Series
 
Rotronic Catalog 2022
Rotronic Catalog 2022Rotronic Catalog 2022
Rotronic Catalog 2022
 
Rotronic RMS Catalog
Rotronic RMS CatalogRotronic RMS Catalog
Rotronic RMS Catalog
 
Fluke Catalog 2022
Fluke Catalog 2022Fluke Catalog 2022
Fluke Catalog 2022
 
Metrel Catalog 2022
Metrel Catalog 2022Metrel Catalog 2022
Metrel Catalog 2022
 
NetAlly Product Family Brochure
NetAlly Product Family BrochureNetAlly Product Family Brochure
NetAlly Product Family Brochure
 

Recently uploaded

Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Dr.Costas Sachpazis
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
ankushspencer015
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Christo Ananth
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
Tonystark477637
 

Recently uploaded (20)

ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 

Data Teknis Gossen Metrawatt Low Resistance Meter

  • 1. 3-447-018-03 1/5.18 GMC-I Messtechnik GmbH METRALINE RLOCHECK Digital Low-Resistance Meter per EN 61557-4 Applications The METRALINE RLO-CHECK is a test instrument for checking the continuity of protective conductors and equipotential bonding.  With the help of the acoustic and luminous signals generated by the test instrument, the user determines whether or not the conti- nuity of the protective conductor and equipotential bonding has an electrical resistance of no greater than 1 . Measurement can be alternatively conducted between two input sockets instead of between a measuring instrument input socket and the cable reel output. Features Interference Voltage Detection If interference voltage is detected at the respective protective con- ductor, resistance measurement is disabled. An intermittent acoustic signal is generated, the color of the display is changed to red and interference voltage is displayed as an RMS value. Input impedance: 300 k, warning range: 8 V~/DC to 400 V~/DC. Balancing and Calibration The measuring instrument can be balanced to 0  with the help of the short-circuit shunt. The threshold for the continuity test can be balanced to 1  with the help of the calibration shunt. Applicable Regulations and Standards IEC 61010-1/-031  DIN EN 61010-1/-031  VDE 0411-1/-031 Safety requirements for electrical equipment for  measurement, control and laboratory use Part 1: General requirements Part 31: Safety requirements for hand-held probe  assemblies for electrical measurement and test DIN EN 61557-1  VDE 0413-1 Electrical safety in low voltage distribution systems up  to 1000 V AC and 1500 V DC – Equipment for testing, measuring or monitoring of protective measures Part 1: General requirements DIN EN 61557-4  VDE 0413-4 Part 4: Resistance of earth connection and  equipotential bonding IEC 61326-1 DIN EN 61326-1 Electrical equipment for measurement, control and  laboratory use – EMC requirements Part 1: General requirements DIN EN 60529 VDE 0470-1 Degrees of protection provided by enclosures (IP code) • Cable reel with 30 m cable • Contact resistance measurement,  measuring range: 0.00  ... 20.0  • Acoustic signaling for continuity (R < 1 ) • Acoustic and optical indication of interference voltage  detection • Interference voltage display: 8 ... 400 V • Automatic polarity reversal per DIN EN 61557-4/VDE 0413-4 • Balancing function for cable reel and accessories  (compensation for up to 4 ) • Test certificate • Extensive accessories
  • 2. Edited in Germany • Subject to change without notice • PDF version available on the Internet METRALINE RLOCHECK Digital Low-Resistance Meter per EN 61557-4 GMC-I Messtechnik GmbH  Südwestpark 15  90449 Nürnberg • Germany Phone: +49-911-8602-111 Fax: +49 911 8602-777 e-mail: info@gossenmetrawatt.com www.gossenmetrawatt.com Characteristic Values Contact Resistance Measurement Range () Resolution () Measuring Uncertainty 0.00 ... 0.49 0.01 0.07  0.50 ... 1.99 0.01 (10% rdg.+0.02 ) 2.00 ... 9.99 0.01 8% rdg. 10.0 ... 20.0 0.1 Measuring voltage: 4 ... 6 V, automatic polarity reversal per DIN EN 61557-4/VDE 0413-4 Measuring current: 200 mA ... 210 mA Key rdg. = reading Ambient Conditions Operating Conditions Operating temperature -20 ... 55 C Relative humidity max. 80% for temperatures of up to 31 C, linear decrease in relative humidity down to 50% at 40 C, no condensation allowed Storage Conditions Temperature -20 ... 55 C Electrical Safety Measuring category With attached test probe cap:  CAT III 600 V / CAT IV 300 V Pollution degree 2 Protection category II Fuse link 500 mA, 6.3 mm x 32 mm,  breaking capacity: 30 kA at 690 V Maximum current in  cable during use as  cable reeling device 0.5 A (protected by fuse) Electromagnetic Compatibility (EMC) Interference emission EN 61326-1:2013 class B Interference immunity EN 61326-1:2013 Mechanical Design Weight 1.3 kg with hip belt Dimensions Drum diameter: 18 cm, height: 12 cm Power Supply Batteries 4 ea. AA battery, 1.5 V alkaline  or 1.2 V NIMH (with at least 750 mAh) (Rechargeable AA batteries can be used but they reduce the period of use). Period of use Approx. 1.7 days under normal conditions of use at 20 C with new batteries. Approx. 5 hours and 50 minutes for con- tinuous measurement of the contact resis- tance of an earthing conductor at less than 1  with activated acoustic signal and new batteries. Battery indicator Battery capacity display via battery symbol Power OFF function The meter is switched off automatically after five minutes of nonuse. Scope of Delivery 1 Measuring instrument 4 Batteries (AA) 1 Hip belt 1 Cable reel with 30 m cable 1 Test probe with protective cap 1 Alligator clip 1 Coil cable (test cable) 1 PE adapter for electric outlets 1 Short-circuit shunt (0 ) 1 Calibration shunt for continuity threshold (1 ) 1 Set of operating instructions 1 Test certificate Order Information Description Type Article Number Digital low-resistance measuring  instrument per DIN EN 61557-4 / VDE 0413-4 with cable reel and 30 m cable for measuring the resis- tance of protective conductors and equipotential bonding METRALINE RLO- CHECK M630W Telescoping rod for RLO and RINS measurements, CAT III 600 V / CAT IV 300 V, 1 A, retracted: 53.5 cm, extended: 120 cm, 190 g TELEARM 120 D) Z505C Telescoping rod for RLO and RINS measurements, CAT III 600 V / CAT IV 300 V, 1 A, retracted: 73.5 cm, extended: 180 cm, 250 g TELEARM 180 D) Z505D D Data sheet available