RESUME
Christopher T. Rounds chris_t_rounds@yahoo.com (717)434-0017
4745 Eagleridge Circle #306 Pueblo, CO 81008
-
EDUCATION
Bellingham Technical College (AAS Instrumentation and Control Systems)
Loyola College at Baltimore (BA Political Science)
*Liberal arts Bachelor degree with heavy emphasis on math and science as well.
U.S. Navy Machinist Mate A School
U.S. Navy Nuclear Power School
U.S. Navy Nuclear Prototype Training
WORK EXPERIENCE
AECOM (Demilitarization of Pueblo U.S. Army Chemical Depot) (3/15-Present)
Position: I&C Technician
Duties performed:
 Responsible for all the instrumentation, SCADA, and analyzer duties on a major
government contract dealing with chemical weapon destruction.
Per Se Group (Citgo Oil Refinery Lemont, IL)(3/14-3/15)
Position: I&C Technician
Duties performed:
 Performed all the duties of a journeyman I&C maintenance technician at a major oil
refinery.
Koch Nitrogen (3/13-3/14)
Position: I&E Technician (Operator Qualified)
Duties performed:
 I was the sole I&E technician at my facility and as such I was responsible for and
performed all I&E duties.
 Read P&ID and electrical diagrams and other complex electrical drawings;
interpreted plant electrical diagrams and updated electrical drawings.
 Performed installation and calibration of 4-20 mA pressure, temperature, flow, and
level transmitters.
 Maintained, modified and troubleshot Distributive Control Systems (DCS) and Allen
Bradley and Modicon Programmable Logic Controllers (PLC), and SCADA.
 Installed, troubleshot and maintained end devices, alarms, shutdown systems, process
controls, substation and branch feeders, variable frequency drives, etc.
 Installed and repaired 120-480V electrical systems.
 Worked directly with regional Electrical Engineer in project involving
demolition and new installation of site substation and controls center.
 Experienced in MOC (Management of Change) process, use of MAXIMO,
ENVIANCE Environmental Compliance, contractor management, and PSM.
British Petroleum (I&E shop)
Position: Instrumentation Technician (Intern 6/12-9-12)
RESUME
Christopher T. Rounds chris_t_rounds@yahoo.com (717)434-0017
4745 Eagleridge Circle #306 Pueblo, CO 81008
-
Duties performed:
 Performed all the duties of a refinery plant I&E technician under direct supervision of
a senior technician
 Gained understanding of calibration accuracy testing requirements and metrology.
U.S. Department of Commerce
Position: Census Supervisor
Social Security Administration
Position: Claims Representative (GS-9 step 1), Occupational Code 0105
The Priority Mortgage Group
Position: Mortgage Loan Officer
Savings 1st Mortgage
Position: Mortgage Loan Officer
MILITARY SERVICE
United States Navy
Machinist Mate (NUCLEAR)
 Served in a leadership role as a non-commissioned officer in the U.S. Navy.
 Adjusted controls to position rod and to regulate flux level, reactor period, coolant
temperature, or rate of power flow, followed standard procedures.
 Implemented operational procedures, such as those controlling start-up or shut-
down activities.
 Responded to system or unit abnormalities, diagnosed the cause, and recommended
or took corrective action.
 Monitored all systems for normal running conditions, performed activities such as
checking gauges to assess output or the effects of generator loading on other
equipment.
 Monitored or operated boilers, turbines, pumps, wells, or auxiliary power plant
equipment.
 Adjusted controls to generate specified electrical power or to regulate the flow of
power between generating stations and substations.
 Controlled power generating equipment, including boilers, turbines, generators, or
reactors, using control boards or semi-automatic equipment.
 Controlled or maintained auxiliary equipment, such as pumps, fans, compressors,
condensers, feed water heaters, filters, or chlorinators, to supply water, fuel,
lubricants, air, or auxiliary power.
 Communicated with systems operators to regulate and coordinate line voltages and
transmission loads and frequencies

Chris Resume 4

  • 1.
    RESUME Christopher T. Roundschris_t_rounds@yahoo.com (717)434-0017 4745 Eagleridge Circle #306 Pueblo, CO 81008 - EDUCATION Bellingham Technical College (AAS Instrumentation and Control Systems) Loyola College at Baltimore (BA Political Science) *Liberal arts Bachelor degree with heavy emphasis on math and science as well. U.S. Navy Machinist Mate A School U.S. Navy Nuclear Power School U.S. Navy Nuclear Prototype Training WORK EXPERIENCE AECOM (Demilitarization of Pueblo U.S. Army Chemical Depot) (3/15-Present) Position: I&C Technician Duties performed:  Responsible for all the instrumentation, SCADA, and analyzer duties on a major government contract dealing with chemical weapon destruction. Per Se Group (Citgo Oil Refinery Lemont, IL)(3/14-3/15) Position: I&C Technician Duties performed:  Performed all the duties of a journeyman I&C maintenance technician at a major oil refinery. Koch Nitrogen (3/13-3/14) Position: I&E Technician (Operator Qualified) Duties performed:  I was the sole I&E technician at my facility and as such I was responsible for and performed all I&E duties.  Read P&ID and electrical diagrams and other complex electrical drawings; interpreted plant electrical diagrams and updated electrical drawings.  Performed installation and calibration of 4-20 mA pressure, temperature, flow, and level transmitters.  Maintained, modified and troubleshot Distributive Control Systems (DCS) and Allen Bradley and Modicon Programmable Logic Controllers (PLC), and SCADA.  Installed, troubleshot and maintained end devices, alarms, shutdown systems, process controls, substation and branch feeders, variable frequency drives, etc.  Installed and repaired 120-480V electrical systems.  Worked directly with regional Electrical Engineer in project involving demolition and new installation of site substation and controls center.  Experienced in MOC (Management of Change) process, use of MAXIMO, ENVIANCE Environmental Compliance, contractor management, and PSM. British Petroleum (I&E shop) Position: Instrumentation Technician (Intern 6/12-9-12)
  • 2.
    RESUME Christopher T. Roundschris_t_rounds@yahoo.com (717)434-0017 4745 Eagleridge Circle #306 Pueblo, CO 81008 - Duties performed:  Performed all the duties of a refinery plant I&E technician under direct supervision of a senior technician  Gained understanding of calibration accuracy testing requirements and metrology. U.S. Department of Commerce Position: Census Supervisor Social Security Administration Position: Claims Representative (GS-9 step 1), Occupational Code 0105 The Priority Mortgage Group Position: Mortgage Loan Officer Savings 1st Mortgage Position: Mortgage Loan Officer MILITARY SERVICE United States Navy Machinist Mate (NUCLEAR)  Served in a leadership role as a non-commissioned officer in the U.S. Navy.  Adjusted controls to position rod and to regulate flux level, reactor period, coolant temperature, or rate of power flow, followed standard procedures.  Implemented operational procedures, such as those controlling start-up or shut- down activities.  Responded to system or unit abnormalities, diagnosed the cause, and recommended or took corrective action.  Monitored all systems for normal running conditions, performed activities such as checking gauges to assess output or the effects of generator loading on other equipment.  Monitored or operated boilers, turbines, pumps, wells, or auxiliary power plant equipment.  Adjusted controls to generate specified electrical power or to regulate the flow of power between generating stations and substations.  Controlled power generating equipment, including boilers, turbines, generators, or reactors, using control boards or semi-automatic equipment.  Controlled or maintained auxiliary equipment, such as pumps, fans, compressors, condensers, feed water heaters, filters, or chlorinators, to supply water, fuel, lubricants, air, or auxiliary power.  Communicated with systems operators to regulate and coordinate line voltages and transmission loads and frequencies