The author proposes a general formula for calculating the load-bearing capacity of a foundation based on several factors. Specifically:
1) The formula depends not only on the properties of the soil but also on the shape, size, depth, and distribution of pressure of the foundation area.
2) It is proposed to calculate the effective area of the foundation by multiplying each foundation element by a factor related to its depth and eccentricity.