ResidualChlorine
Transmitter
Model Q45H/62-63
ATI’s Residual Chlorine Transmitter is designed for on-line monitoring and control
of chlorination systems. It is available in two versions: a Free Chlorine Monitor
for drinking and cooling water systems, and a Combined Chlorine Monitor ideally
suited for “chloraminated” drinking water. The Combined Chlorine System can
also be used in wastewater effluents where sufficient ammonia is present prior to
chlorination to result in a predominantly monochloramine residual.
Unlike on-line colorimetric and most amperometric monitors, Q45H systems utilize
a membrane-covered polarographic sensor that does not require the addition of
chemical reagents. That means no more costly reagents to purchase or flow cells
that require frequent cleaning. All that’s needed is a constant flow of water across
the face of the sensor, and this is provided by a sample constant-head flowcell.
The Q45H system has no moving parts, so there are no pumps or motors that burn
out, or tubing breaks that create maintenance nightmares. All normal maintenance
items are included with each system. The Q45H Chlorine Monitoring System is easy
to operate, requires minimal maintenance, and will not eat a hole in your operating
budget with ongoing reagent requirements or component replacement costs.
PotableWaterTreatment		 CoolingTowers
RO Membrane Protection		 WastewaterTreatment
Chloramination Systems		 FoodWashWater
Applications
• Free or Combined Chlorine monitoring
• Loop-powered or battery operation
• External 5-17VDC version for solar power applications
• Reagent free measurement
• pH compensation for operation to pH of 9.5
• Measurement from 0-200 ppb to 0-200 ppm
• Constant-head flowcell simplifies operation
• Large, easy-to-read LCD display
• Clear, menu-driven user interface
• NEMA 4X (IP-66) enclosure
• Wall or pipe mounting bracket standard
• Built-in PID controller
Features
Sensor & Flowcell Options
Constant Head Flowcell
Sealed Flowcell
Submersible Sensor
ModelQ45H/62-63SPECIFICATIONS
ELECTRONICTRANSMITTER
Visit Us on the Web: www.analyticaltechnology.com
Represented by:
AnalyticalTechnology, Inc.
6 Iron Bridge Drive
Collegeville, PA 19462
Phone 610.917.0991
Toll-Free 800.959.0299
Fax 610.917.0992
Email sales@analyticaltechnology.com
AnalyticalTechnology
Unit1&2-GateheadBusinessPark
DelphNewRoad,Delph
SaddleworthOL35DE
Phone01457873318
Fax01457874468
Emailsales@atiuk.com
ORDERING INFORMATION
Model Q45H-A-B-C-D Residual ChlorineTransmitter
B
/
Q45H62-63
/
R-1
(5/2014)
Chlorine Sensor Membrane-covered Amperometric (Polarographic)
Optional pH Sensor pH sensor, with or without preamplifier
Materials PVC & 316 stainless steel
ResponseTime 90% in 60 seconds
Temperature Limits 0-50°C
Pressure Limit 0-50 psig
Sensor Cable 25 ft. (7.5 m) standard
Sensor Flowcell Clearacrylicconstant-headoverfloworsealedacrylicflowcell
Sample Flow rate 7-15 GPH (0.5-1.0 LPM)
SENSOR & FLOWCELL SPECIFICATIONS
Suffix A - MeasurementType
62 - Free Chlorine
63 - Combined Chlorine
Suffix B - Power
1 - 24VDC, 2-wire (single output only)
4 - Battery operated with two 0-2.5VDC outputs
5 - External 5-17VDC with two 0-2.5VDC outputs
Suffix C - Sensor Style
1 - Sensor with constant head flowcell and 25’cable
2-Submersiblesensorwith25’cable (Chloraminesensoronly)
3 - Sensor with sealed low-volume flowcell
4 - Sensor with 1-1/2”Flow“T” (Chloraminesensoronly)
5 - Sensor with sealed flowcell
Suffix D - pH Sensor Input
1 - None
2 - Q22 pH sensor with battery preamp, 25 ft. cable
3 - Standard pH sensor with 25 ft. cable & adapter for overflow cell
4 - Standard pH sensor with 25 ft. cable & sealed flowcell
ACCESSORIES
07-0100 Universal junction box, NEMA 4X
31-0001 5-c sensor interconnect cable, max. 100 ft. (Cl2 only)
31-0038 7-csensorinterconnectcable,max.100ft. (Cl2 /pHsystems)
00-0628 Mounting bracket kit for submersible sensor
00-0930 Monitor pipe mounting bracket kit
00-0570 Free Chlorine polarizer, flow cell style
00-0572 Combined Chlorine polarizer, flow cell style
00-0573 Combined Chlorine polarizer, submersible style
47-0005 2”U-bolt, 304SS
55-0048 Fixed flow regulator, 400 cc/min., 1/4”inlet & outlet
NOTES:
1 - All systems are supplied with one package of membranes, one
120 cc bottle of electrolyte, and one spare parts kit containing 3
each of all o-rings and special screws.
2 - FlowcellforCl2 systemsshouldbekeptwithin25feetofmonitor.
3 - Pipe mount requires two 2”U-bolts (47-0005).
Display Range 0-200 ppb; 0-2.000, 0-20.00, 0-200.0 ppm or mg/l
Accuracy +0.5% of selected range or 0.02 ppm
Repeatability 0.3% of selected range or 0.01 ppm
Sensitivity 0.05% of selected range
Linearity 0.1% of selected range
Temperature Drift 0.1% of span/°C
SensorType 2E Amperometric (Polargraphic) membraned sensor
Temperature Input Pt100 in sensor for temperature compensation
Power
2-Wire unit: 17-30VDC, 25 mA maximum
Battery unit:Two AA Alkaline batteries
External DC: 5-17VDC, 10 mA maximum
Analog Outputs
2-Wire unit: Single 4-20 mA DC, 450 ohms maximum
Battery unit:Two 0-2.5VDC, 50K ohms minimum
External DC:Two 0-2.5VDC, 50K ohms minimum
Output Isolation 600V Galvanic isolation
Enclosure NEMA 4X (IP-66) Polycarbanate,V-0 flammability
Mounting Options Wall or pipe mounting bracket supplied
Conduit Entries Two PG-9 cord grips, 0.16-0.31”diameter cable
AmbientTemperature
Operating: -40° to + 60°C
Storage: -40° to + 70°C
Ambient Humidity 0-95%, Non-condensing
Size 4.4”H x 4.4”W x 3.5”D (111 x 111 x 90 mm)
Weight
2-Wire or External DC unit: 1 lb (0.45 Kg)
Battery unit: 2 lbs (0.9 Kg)
Certifications
CE marked to BS EN 61326-1:2006 Standard
UL and CSA General Purpose

More Related Content

Similar to ATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdf

CCS 120 endress+hauser datasheet-sensor for total chlorine
CCS 120 endress+hauser datasheet-sensor for total chlorineCCS 120 endress+hauser datasheet-sensor for total chlorine
CCS 120 endress+hauser datasheet-sensor for total chlorine
ENVIMART
 
ATI-Q46H-C4-Datasheet.pdf
ATI-Q46H-C4-Datasheet.pdfATI-Q46H-C4-Datasheet.pdf
ATI-Q46H-C4-Datasheet.pdf
ENVIMART
 
Q46CT-Toroidal-Conductivity-Monitor.pdf
Q46CT-Toroidal-Conductivity-Monitor.pdfQ46CT-Toroidal-Conductivity-Monitor.pdf
Q46CT-Toroidal-Conductivity-Monitor.pdf
ENVIMART
 
Process Control Solution Product Details
Process Control Solution Product DetailsProcess Control Solution Product Details
Process Control Solution Product Details
Process Control Solutions
 
ATI-Q46F.pdf
ATI-Q46F.pdfATI-Q46F.pdf
ATI-Q46F.pdf
ENVIMART
 
ATI_Q46PR.pdf
ATI_Q46PR.pdfATI_Q46PR.pdf
ATI_Q46PR.pdf
ENVIMART
 
CCS 140 141 endress+hauser datasheet-sensors for free chlorine
CCS 140 141 endress+hauser datasheet-sensors for free chlorineCCS 140 141 endress+hauser datasheet-sensors for free chlorine
CCS 140 141 endress+hauser datasheet-sensors for free chlorine
ENVIMART
 
Q46FN-Free-Ammonia-Auto-Chem-System.pdf
Q46FN-Free-Ammonia-Auto-Chem-System.pdfQ46FN-Free-Ammonia-Auto-Chem-System.pdf
Q46FN-Free-Ammonia-Auto-Chem-System.pdf
ENVIMART
 
ATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdf
ATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdfATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdf
ATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdf
ENVIMART
 
Q46-76-Turbidity-Monitor.pdf
Q46-76-Turbidity-Monitor.pdfQ46-76-Turbidity-Monitor.pdf
Q46-76-Turbidity-Monitor.pdf
ENVIMART
 
Automatic stationary sampler-Liquistation CSF34
Automatic stationary sampler-Liquistation CSF34Automatic stationary sampler-Liquistation CSF34
Automatic stationary sampler-Liquistation CSF34
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
ENVIMART
 
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitterLiquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
ENVIMART
 
Q45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdf
Q45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdfQ45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdf
Q45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdf
ENVIMART
 
ATI-Q46H-83-Datasheet.pdf
ATI-Q46H-83-Datasheet.pdfATI-Q46H-83-Datasheet.pdf
ATI-Q46H-83-Datasheet.pdf
ENVIMART
 
Q46S-66-Auto-Chem-Sulfite-Monitor.pdf
Q46S-66-Auto-Chem-Sulfite-Monitor.pdfQ46S-66-Auto-Chem-Sulfite-Monitor.pdf
Q46S-66-Auto-Chem-Sulfite-Monitor.pdf
ENVIMART
 
Bubble-Tube Liquid Level System
Bubble-Tube Liquid Level SystemBubble-Tube Liquid Level System
Bubble-Tube Liquid Level System
Hile Controls of Alabama, Inc.
 
Flash chromatography
Flash chromatographyFlash chromatography
Flash chromatography
Girija Dandu
 
Allwin21 Product Brochures-Upgrade Kits-2024.5.pdf
Allwin21 Product Brochures-Upgrade Kits-2024.5.pdfAllwin21 Product Brochures-Upgrade Kits-2024.5.pdf
Allwin21 Product Brochures-Upgrade Kits-2024.5.pdf
Peter Chen
 
PCS
PCSPCS

Similar to ATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdf (20)

CCS 120 endress+hauser datasheet-sensor for total chlorine
CCS 120 endress+hauser datasheet-sensor for total chlorineCCS 120 endress+hauser datasheet-sensor for total chlorine
CCS 120 endress+hauser datasheet-sensor for total chlorine
 
ATI-Q46H-C4-Datasheet.pdf
ATI-Q46H-C4-Datasheet.pdfATI-Q46H-C4-Datasheet.pdf
ATI-Q46H-C4-Datasheet.pdf
 
Q46CT-Toroidal-Conductivity-Monitor.pdf
Q46CT-Toroidal-Conductivity-Monitor.pdfQ46CT-Toroidal-Conductivity-Monitor.pdf
Q46CT-Toroidal-Conductivity-Monitor.pdf
 
Process Control Solution Product Details
Process Control Solution Product DetailsProcess Control Solution Product Details
Process Control Solution Product Details
 
ATI-Q46F.pdf
ATI-Q46F.pdfATI-Q46F.pdf
ATI-Q46F.pdf
 
ATI_Q46PR.pdf
ATI_Q46PR.pdfATI_Q46PR.pdf
ATI_Q46PR.pdf
 
CCS 140 141 endress+hauser datasheet-sensors for free chlorine
CCS 140 141 endress+hauser datasheet-sensors for free chlorineCCS 140 141 endress+hauser datasheet-sensors for free chlorine
CCS 140 141 endress+hauser datasheet-sensors for free chlorine
 
Q46FN-Free-Ammonia-Auto-Chem-System.pdf
Q46FN-Free-Ammonia-Auto-Chem-System.pdfQ46FN-Free-Ammonia-Auto-Chem-System.pdf
Q46FN-Free-Ammonia-Auto-Chem-System.pdf
 
ATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdf
ATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdfATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdf
ATI-Q46S-66-Datasheet Auto Chem Sulfite Monitor.pdf
 
Q46-76-Turbidity-Monitor.pdf
Q46-76-Turbidity-Monitor.pdfQ46-76-Turbidity-Monitor.pdf
Q46-76-Turbidity-Monitor.pdf
 
Automatic stationary sampler-Liquistation CSF34
Automatic stationary sampler-Liquistation CSF34Automatic stationary sampler-Liquistation CSF34
Automatic stationary sampler-Liquistation CSF34
 
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
 
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitterLiquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
 
Q45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdf
Q45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdfQ45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdf
Q45C2-2-Electrode-Conductivity-Monitor-Product-Literature.pdf
 
ATI-Q46H-83-Datasheet.pdf
ATI-Q46H-83-Datasheet.pdfATI-Q46H-83-Datasheet.pdf
ATI-Q46H-83-Datasheet.pdf
 
Q46S-66-Auto-Chem-Sulfite-Monitor.pdf
Q46S-66-Auto-Chem-Sulfite-Monitor.pdfQ46S-66-Auto-Chem-Sulfite-Monitor.pdf
Q46S-66-Auto-Chem-Sulfite-Monitor.pdf
 
Bubble-Tube Liquid Level System
Bubble-Tube Liquid Level SystemBubble-Tube Liquid Level System
Bubble-Tube Liquid Level System
 
Flash chromatography
Flash chromatographyFlash chromatography
Flash chromatography
 
Allwin21 Product Brochures-Upgrade Kits-2024.5.pdf
Allwin21 Product Brochures-Upgrade Kits-2024.5.pdfAllwin21 Product Brochures-Upgrade Kits-2024.5.pdf
Allwin21 Product Brochures-Upgrade Kits-2024.5.pdf
 
PCS
PCSPCS
PCS
 

More from ENVIMART

Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdfZinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdfNickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdfManganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdfLead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdfIron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdfIron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdfChromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdfCopper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdfCopper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdfCopper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdfCobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdfCadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdfArsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdfAluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
ENVIMART
 
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdfATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ENVIMART
 
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdfATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ENVIMART
 
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdfATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ENVIMART
 
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdfATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ENVIMART
 
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdfATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ENVIMART
 
B12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdfB12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdf
ENVIMART
 

More from ENVIMART (20)

Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdfZinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
 
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdfNickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
 
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdfManganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
 
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdfLead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
 
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdfIron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
 
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdfIron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
 
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdfChromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
 
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdfCopper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
 
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdfCopper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
 
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdfCopper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
 
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdfCobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
 
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdfCadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
 
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdfArsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
 
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdfAluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
 
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdfATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
 
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdfATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
 
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdfATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
 
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdfATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
 
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdfATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
 
B12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdfB12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdf
 

Recently uploaded

world-environment-day-2024-240601103559-14f4c0b4.pptx
world-environment-day-2024-240601103559-14f4c0b4.pptxworld-environment-day-2024-240601103559-14f4c0b4.pptx
world-environment-day-2024-240601103559-14f4c0b4.pptx
mfasna35
 
Wildlife-AnIntroduction.pdf so that you know more about our environment
Wildlife-AnIntroduction.pdf so that you know more about our environmentWildlife-AnIntroduction.pdf so that you know more about our environment
Wildlife-AnIntroduction.pdf so that you know more about our environment
amishajha2407
 
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...Kinetic studies on malachite green dye adsorption from aqueous solutions by A...
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...
Open Access Research Paper
 
Environment Conservation Rules 2023 (ECR)-2023.pptx
Environment Conservation Rules 2023 (ECR)-2023.pptxEnvironment Conservation Rules 2023 (ECR)-2023.pptx
Environment Conservation Rules 2023 (ECR)-2023.pptx
neilsencassidy
 
Biomimicry in agriculture: Nature-Inspired Solutions for a Greener Future
Biomimicry in agriculture: Nature-Inspired Solutions for a Greener FutureBiomimicry in agriculture: Nature-Inspired Solutions for a Greener Future
Biomimicry in agriculture: Nature-Inspired Solutions for a Greener Future
Dr. P.B.Dharmasena
 
Lessons from operationalizing integrated landscape approaches
Lessons from operationalizing integrated landscape approachesLessons from operationalizing integrated landscape approaches
Lessons from operationalizing integrated landscape approaches
CIFOR-ICRAF
 
原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样
原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样
原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样
p2npnqp
 
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...
Joshua Orris
 
PACKAGING OF FROZEN FOODS ( food technology)
PACKAGING OF FROZEN FOODS  ( food technology)PACKAGING OF FROZEN FOODS  ( food technology)
PACKAGING OF FROZEN FOODS ( food technology)
Addu25809
 
原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样
原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样
原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样
mvrpcz6
 
在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样
在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样
在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样
pjq9n1lk
 
RoHS stands for Restriction of Hazardous Substances, which is also known as t...
RoHS stands for Restriction of Hazardous Substances, which is also known as t...RoHS stands for Restriction of Hazardous Substances, which is also known as t...
RoHS stands for Restriction of Hazardous Substances, which is also known as t...
vijaykumar292010
 
Improving the viability of probiotics by encapsulation methods for developmen...
Improving the viability of probiotics by encapsulation methods for developmen...Improving the viability of probiotics by encapsulation methods for developmen...
Improving the viability of probiotics by encapsulation methods for developmen...
Open Access Research Paper
 
快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样
快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样
快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样
astuz
 
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...
Joshua Orris
 
BASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENT
BASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENTBASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENT
BASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENT
AmitKumar619042
 

Recently uploaded (16)

world-environment-day-2024-240601103559-14f4c0b4.pptx
world-environment-day-2024-240601103559-14f4c0b4.pptxworld-environment-day-2024-240601103559-14f4c0b4.pptx
world-environment-day-2024-240601103559-14f4c0b4.pptx
 
Wildlife-AnIntroduction.pdf so that you know more about our environment
Wildlife-AnIntroduction.pdf so that you know more about our environmentWildlife-AnIntroduction.pdf so that you know more about our environment
Wildlife-AnIntroduction.pdf so that you know more about our environment
 
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...Kinetic studies on malachite green dye adsorption from aqueous solutions by A...
Kinetic studies on malachite green dye adsorption from aqueous solutions by A...
 
Environment Conservation Rules 2023 (ECR)-2023.pptx
Environment Conservation Rules 2023 (ECR)-2023.pptxEnvironment Conservation Rules 2023 (ECR)-2023.pptx
Environment Conservation Rules 2023 (ECR)-2023.pptx
 
Biomimicry in agriculture: Nature-Inspired Solutions for a Greener Future
Biomimicry in agriculture: Nature-Inspired Solutions for a Greener FutureBiomimicry in agriculture: Nature-Inspired Solutions for a Greener Future
Biomimicry in agriculture: Nature-Inspired Solutions for a Greener Future
 
Lessons from operationalizing integrated landscape approaches
Lessons from operationalizing integrated landscape approachesLessons from operationalizing integrated landscape approaches
Lessons from operationalizing integrated landscape approaches
 
原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样
原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样
原版制作(Newcastle毕业证书)纽卡斯尔大学毕业证在读证明一模一样
 
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...
Optimizing Post Remediation Groundwater Performance with Enhanced Microbiolog...
 
PACKAGING OF FROZEN FOODS ( food technology)
PACKAGING OF FROZEN FOODS  ( food technology)PACKAGING OF FROZEN FOODS  ( food technology)
PACKAGING OF FROZEN FOODS ( food technology)
 
原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样
原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样
原版制作(Manitoba毕业证书)曼尼托巴大学毕业证学位证一模一样
 
在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样
在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样
在线办理(lboro毕业证书)拉夫堡大学毕业证学历证书一模一样
 
RoHS stands for Restriction of Hazardous Substances, which is also known as t...
RoHS stands for Restriction of Hazardous Substances, which is also known as t...RoHS stands for Restriction of Hazardous Substances, which is also known as t...
RoHS stands for Restriction of Hazardous Substances, which is also known as t...
 
Improving the viability of probiotics by encapsulation methods for developmen...
Improving the viability of probiotics by encapsulation methods for developmen...Improving the viability of probiotics by encapsulation methods for developmen...
Improving the viability of probiotics by encapsulation methods for developmen...
 
快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样
快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样
快速办理(Calabria毕业证书)卡拉布里亚大学毕业证在读证明一模一样
 
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...
Evolving Lifecycles with High Resolution Site Characterization (HRSC) and 3-D...
 
BASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENT
BASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENTBASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENT
BASIC CONCEPT OF ENVIRONMENT AND DIFFERENT CONSTITUTENET OF ENVIRONMENT
 

ATI-Q45H-62-63-Residual-Chlorine-Datasheet.pdf

  • 1. Call 800.959.0299 to speak with a sales representative or visit us on the web at www.analyticaltechnology.com ResidualChlorine Transmitter Model Q45H/62-63 ATI’s Residual Chlorine Transmitter is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a Free Chlorine Monitor for drinking and cooling water systems, and a Combined Chlorine Monitor ideally suited for “chloraminated” drinking water. The Combined Chlorine System can also be used in wastewater effluents where sufficient ammonia is present prior to chlorination to result in a predominantly monochloramine residual. Unlike on-line colorimetric and most amperometric monitors, Q45H systems utilize a membrane-covered polarographic sensor that does not require the addition of chemical reagents. That means no more costly reagents to purchase or flow cells that require frequent cleaning. All that’s needed is a constant flow of water across the face of the sensor, and this is provided by a sample constant-head flowcell. The Q45H system has no moving parts, so there are no pumps or motors that burn out, or tubing breaks that create maintenance nightmares. All normal maintenance items are included with each system. The Q45H Chlorine Monitoring System is easy to operate, requires minimal maintenance, and will not eat a hole in your operating budget with ongoing reagent requirements or component replacement costs. PotableWaterTreatment CoolingTowers RO Membrane Protection WastewaterTreatment Chloramination Systems FoodWashWater Applications • Free or Combined Chlorine monitoring • Loop-powered or battery operation • External 5-17VDC version for solar power applications • Reagent free measurement • pH compensation for operation to pH of 9.5 • Measurement from 0-200 ppb to 0-200 ppm • Constant-head flowcell simplifies operation • Large, easy-to-read LCD display • Clear, menu-driven user interface • NEMA 4X (IP-66) enclosure • Wall or pipe mounting bracket standard • Built-in PID controller Features Sensor & Flowcell Options Constant Head Flowcell Sealed Flowcell Submersible Sensor
  • 2. ModelQ45H/62-63SPECIFICATIONS ELECTRONICTRANSMITTER Visit Us on the Web: www.analyticaltechnology.com Represented by: AnalyticalTechnology, Inc. 6 Iron Bridge Drive Collegeville, PA 19462 Phone 610.917.0991 Toll-Free 800.959.0299 Fax 610.917.0992 Email sales@analyticaltechnology.com AnalyticalTechnology Unit1&2-GateheadBusinessPark DelphNewRoad,Delph SaddleworthOL35DE Phone01457873318 Fax01457874468 Emailsales@atiuk.com ORDERING INFORMATION Model Q45H-A-B-C-D Residual ChlorineTransmitter B / Q45H62-63 / R-1 (5/2014) Chlorine Sensor Membrane-covered Amperometric (Polarographic) Optional pH Sensor pH sensor, with or without preamplifier Materials PVC & 316 stainless steel ResponseTime 90% in 60 seconds Temperature Limits 0-50°C Pressure Limit 0-50 psig Sensor Cable 25 ft. (7.5 m) standard Sensor Flowcell Clearacrylicconstant-headoverfloworsealedacrylicflowcell Sample Flow rate 7-15 GPH (0.5-1.0 LPM) SENSOR & FLOWCELL SPECIFICATIONS Suffix A - MeasurementType 62 - Free Chlorine 63 - Combined Chlorine Suffix B - Power 1 - 24VDC, 2-wire (single output only) 4 - Battery operated with two 0-2.5VDC outputs 5 - External 5-17VDC with two 0-2.5VDC outputs Suffix C - Sensor Style 1 - Sensor with constant head flowcell and 25’cable 2-Submersiblesensorwith25’cable (Chloraminesensoronly) 3 - Sensor with sealed low-volume flowcell 4 - Sensor with 1-1/2”Flow“T” (Chloraminesensoronly) 5 - Sensor with sealed flowcell Suffix D - pH Sensor Input 1 - None 2 - Q22 pH sensor with battery preamp, 25 ft. cable 3 - Standard pH sensor with 25 ft. cable & adapter for overflow cell 4 - Standard pH sensor with 25 ft. cable & sealed flowcell ACCESSORIES 07-0100 Universal junction box, NEMA 4X 31-0001 5-c sensor interconnect cable, max. 100 ft. (Cl2 only) 31-0038 7-csensorinterconnectcable,max.100ft. (Cl2 /pHsystems) 00-0628 Mounting bracket kit for submersible sensor 00-0930 Monitor pipe mounting bracket kit 00-0570 Free Chlorine polarizer, flow cell style 00-0572 Combined Chlorine polarizer, flow cell style 00-0573 Combined Chlorine polarizer, submersible style 47-0005 2”U-bolt, 304SS 55-0048 Fixed flow regulator, 400 cc/min., 1/4”inlet & outlet NOTES: 1 - All systems are supplied with one package of membranes, one 120 cc bottle of electrolyte, and one spare parts kit containing 3 each of all o-rings and special screws. 2 - FlowcellforCl2 systemsshouldbekeptwithin25feetofmonitor. 3 - Pipe mount requires two 2”U-bolts (47-0005). Display Range 0-200 ppb; 0-2.000, 0-20.00, 0-200.0 ppm or mg/l Accuracy +0.5% of selected range or 0.02 ppm Repeatability 0.3% of selected range or 0.01 ppm Sensitivity 0.05% of selected range Linearity 0.1% of selected range Temperature Drift 0.1% of span/°C SensorType 2E Amperometric (Polargraphic) membraned sensor Temperature Input Pt100 in sensor for temperature compensation Power 2-Wire unit: 17-30VDC, 25 mA maximum Battery unit:Two AA Alkaline batteries External DC: 5-17VDC, 10 mA maximum Analog Outputs 2-Wire unit: Single 4-20 mA DC, 450 ohms maximum Battery unit:Two 0-2.5VDC, 50K ohms minimum External DC:Two 0-2.5VDC, 50K ohms minimum Output Isolation 600V Galvanic isolation Enclosure NEMA 4X (IP-66) Polycarbanate,V-0 flammability Mounting Options Wall or pipe mounting bracket supplied Conduit Entries Two PG-9 cord grips, 0.16-0.31”diameter cable AmbientTemperature Operating: -40° to + 60°C Storage: -40° to + 70°C Ambient Humidity 0-95%, Non-condensing Size 4.4”H x 4.4”W x 3.5”D (111 x 111 x 90 mm) Weight 2-Wire or External DC unit: 1 lb (0.45 Kg) Battery unit: 2 lbs (0.9 Kg) Certifications CE marked to BS EN 61326-1:2006 Standard UL and CSA General Purpose