This quick reference card summarizes the main functions of a spa control system. It describes how to start the pump, turn on the light, set the water temperature and filter cycle duration. It also provides troubleshooting tips for issues like high water temperature or system errors. The system can run one or two pumps, and some models include a blower option. All settings are controlled through the digital control pad.
Wholesale Pool and Spa Parts Quick Reference Card Overview
1. SC-CF-SBD
•Single-Pump System •
K-19 (7'' • 3 1/4'')
The Quick Reference Card provides a quick overview of your spa's main K-18 (5'' • 2 1/2'')
functions and the operations accessible with your digital control pad.
N.B.: CP option is only available on dual pump systems.
Starting the pump: Programming filter cycle duration
The system automatically performs 2 filter cycles per day, at 12-hour intervals.
During a filter cycle, pump runs for a programmed number of hours.
Setting filter cycle duration:
Press Pump to turn pump on. Press a second time
to change pump speed. A third time turns pump off.
A built-in timer turns pump off after 20 minutes,
unless manually deactivated first.
The "Pump" indicator lights up when pump is on.
Turning the light on: Press and hold Light key for Use Up/Down arrow keys to When the desired setting is dis-
5 seconds. The display will change setting. played, press Light key again.
show a value that represents 0 = no filtration The filter cycle will start. The
filter cycle duration in hours. 12 = continuous filtration "Filter" indicator lights up when
a filter cycle is on.
An irregularly flashing "Filter Cycle" indicator means that the system has stopped filtering after 3 hours
because water temperature exceeds the Set Point by more than 2˚F (1˚C). If the temperature cools
down before the scheduled end of the cycle, filtering will resume for the remainder of the programmed
cycle duration.
N.B.: After a power failure, the filter cycle duration will return to its default value. In this case, the first
Press Light to turn light on. Press a second time to filter cycle will start 12 hours after power has been restored.
turn light off. The light turns off after 2 hours, unless
it has been manually deactivated.
The "Light" indicator is displayed when light is on.
Automatic water heater start: Troubleshooting
The pump has started up Water temperature is flashing. 3 flashing dots are displayed.
for one minute on several
occasions and "Filter" Water temperature in the spa A problem has been detected.
When water temperature is 1°F (0.5°C) lower than indicator is flashing. has reached 112°F (44°C).
Set Point, the heater will automatically turn on until Do not enter the water! Check
water temperature reaches Set Point plus 1°F (0.5°C). Not a bug but a feature! Do not enter the water! Allow and open water valves. Clean
The "Heater" indicator lights up when the heater is on. water to cool down. The sys- filters if necessary. Check water
Our Smart Winter Mode tem will reset automatically level. Add water if needed.
protects your spa from the when water temperature Shut power off and power your
cold by automatically turning reaches 109°F (43°C). spa up again to reset the system.
Setting water temperature: pump on for one minute Call your dealer or service Call your dealer or service sup-
several times a day to prevent supplier if problem persists. plier if problem persists.
water from freezing in pipes.
The "Heater" indicator The display is flashing.
Use Up/Down arrow keys to regulate water is flashing when pump
s on at high speed. A power failure has occurred.
temperature. Press and hold key to increase or Press any key to reset the system
decrease current water temperature setting. The and reprogram all desired param-
temperature setting is displayed for 5 seconds to Not a bug but a feature!
eters.
confirm your new selection.
The heater is turned off when
The "Set Point" indicator shows the desired tem- pump is on at high speed to
perature, NOT the current water temperature! limit the electrical current drawn.
Water temperature can be adjusted by 1°
increments from 59 to 104°F (15 to 40°C). •E
QU
IPP
ED W
ITH GECKO'S EX
CLU
SIV
E•
Smart
Winter
Mode
TM
3-85-7073-D Quick Reference Card
http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
2. •
SC-CF-SBD System
Single-Pump & Blower or Dual-Pump •
K-19 (7'' • 3 1/4'')
The Quick Reference Card provides a quick overview of your spa's main K-18 (5'' • 2 1/2'')
functions and the operations accessible with your digital control pad.
N.B.: Blower option is available on both K-19 & K-18 keypads.
Starting Pump 1: Automatic water heater start:
When water temperature is 1°F (0.5°C) lower than Set Point, the heater will automatically turn on until
water temperature reaches Set Point plus 1°F (0.5°C). The "Heater" indicator lights up when heater is on.
Programming Filter Cycle Duration
The system automatically performs 2 filter cycles per day, at 12-hour intervals. During a filter cycle,
pump runs for a programmed number of hours. To set filter cycle duration:
Press Pump 1 to turn Pump 1 on. Press a second time
to change Pump 1 speed. A third time turns Pump 1
off. A built-in timer turns Pump 1 off after 20 minutes,
unless manually deactivated first.
The "Pump 1" indicator lights up when Pump 1 is on.
Starting Pump 2/ blower:
Press and hold Light key for Use Up/Down arrow key to When the desired setting is dis-
5 seconds. The display will change setting. played, press Light key again.
show a value that represents 0 = no filtration The filter cycle will start.
filter cycle duration in hours. 12 = continuous filtration The "Filter" indicator lights
up when a filter cycle is on.
An irregularly flashing "Filter Cycle" indicator means that the system has stopped filtering after 3 hours
because water temperature exceeds the Set Point by more than 2˚F (1˚C). If the temperature cools
Press Pump 2 to turn Pump 2/ blower on. down before the scheduled end of the cycle, filtering will resume for the remainder of the programmed
A second time turns Pump 2/ blower off. A built-in cycle duration.
timer turns Pump 2/ blower off after 20 minutes,
unless manually deactivated first. N.B.: After a power failure, the filter cycle duration will return to its default value. In this case, the first
filter cycle will start 12 hours after power has been restored.
"Pump 2" indicator lights up when Pump 2/ blower
is on.
Turning the light on:
Troubleshooting
The pump has started up Water temperature 3 flashing dots are displayed.
for one minute on several is flashing.
Press Light to turn light on. Press a second time to occasions and "Filter" A problem has been detected.
turn light off. The light turns off after 2 hours, unless it indicator is flashing. Water temperature in the spa
has reached 112°F (44°C). Do not enter the water! Check
has been manually deactivated. and open water valves. Clean
Not a bug but a feature!
The "Light" indicator is displayed when light is on. Do not enter the water! Allow filters if necessary. Check water
Our Smart Winter Mode water to cool down. The sys- level. Add water if needed.
protects your spa from the cold tem will reset automatically
Setting water temperature: by automatically turning pump when water temperature Shut power off and power your
spa up again to reset the system.
on for one minute several times reaches 109°F (43°C).
a day to prevent water from
freezing in pipes. Call your dealer or service Call your dealer or service sup-
supplier if problem persists. plier if problem persists.
The "Heater" indicator is The display is flashing.
Use Up/Down arrow key to regulate water temper- flashing when pump is on
ature. Press and hold key to increase or decrease at high speed. A power failure has occurred.
current water temperature setting. The temperature Press any key to reset the system
setting is displayed for 5 seconds to confirm your Not a bug but a feature! and reprogram all desired param-
new selection. eters.
The heater is turned off when
The "Set Point" indicator shows the desired temper- pump is on at high speed to
ature, NOT the current water temperature! Water limit the electrical current drawn.
temperature can be adjusted by 1° increments from
59 to 104°F (15 to 40°C).
ITH GECKO'S EX
ED W CLU
IPP SIV
QU E•
•E
Smart
Winter
Mode
TM
3-85-7073-D Quick Reference Card