1. This drawing is the copyright of NMW Design. It must not be reproduced or used in
any form without the express written permission of NMW Design.
All dimensions to be checked on site prior to commencement of any works.
Do not scale from this drawing only use written dimensions.
The contractor is to verify all dimensions, heights and levels prior to
commencement of work.
Any discrepancies are to be reported immediately to NMW Design.
No encroachment is to be made onto any neighbouring property without obtaining
the written permission of the neighbour.
The contractor shall visit the site and familiarise himself with the project prior to
preparing his estimate. He shall allow in his price for any detail whether indicated or
not which may be reasonably considered necessary to ensure a neat and
structurally sound and workmanlike job.
The contractor shall issue all statutory notices to the Local Authority prior to
commencement, during progress and completion of the works.
B A B A B A
New uPVC double New uPVC double
glazed window glazed window
Lounge Bed 2 Bed 1 Bed 5 Bed 4
External walls to be battened at 600mm
ctrs to receive 62.5mm Kingspan
Kooltherm K18 insulated plasterboard
Battens to be backed with dpm.
FD30 Fire Door FD30 Fire Door FD30 Fire Door
FD30 Fire Door FD30 Fire Door
Mechanical extractor FD30 Fire Door
FD30 Fire Door FD30 Fire Door FD30 Fire Door
SD
WC SD
6ltrs/sec air change with
15min overrun WC SD
Interlinked smoke detector Interlinked smoke detector
Interlinked smoke detector
wired to mains wired to mains
wired to mains
Mechanical extractor
New brickwork to be tied to 30ltrs/sec air change
New brickwork to be tied to existing using remedial with 15min overrun
existing using remedial
wall ties St wall ties
New walls to comprise 100mm facing
bricks, 50mm clear cavity, 50mm
New uPVC obscure
double glazed window
Kingspan Kooltherm K8 insulation with
Kitchen 100mm medium density blockwork giving
Bath Bed 3 Bath Bed 6 New uPVC double
Existing SVP to be
glazed window
renewed
R.W.P.
L1/S 100 900 lintel over
Min Going 220mm
Dining L1/E 100 900 lintel over
Velux MO8
GGL3059
Max Rise 198mm
780 x 1400
Balustrades to prevent passage
Staircase manufacturer to
L1/S 100 1200 lintel over check dims on site prior to
3
manufacturing staircase FD30 Fire Door
4
SD 5 1 2 3 4 5 6 7 1 2 3 4 5 6 7
Interlinked smoke detector
wired to mains
Up FD30 Fire Door FD30 Fire Door
Office Up
6
7 Up
Min Going 220mm
Max Rise 181mm
Balustrades to prevent passage
External walls to be battened at 600mm Up
ctrs to receive 62.5mm Kingspan
Screen Fence
Hall SD
Interlinked smoke detector
8
9
Staircase manufacturer to
check dims on site prior to
Kooltherm K18 insulated plasterboard
Battens to be backed with dpm.
wired to mains manufacturing staircase
Line WC with 12.5mm
Soundbloc plasterboard
Mechanical extractor
Kitchen Coats
10
11 Vaulted Ceiling to
Sitting Room
12
6ltrs/sec air change with
15min overrun ducted to
gable in boxing under floor
13 Sitting Room
soffit
WC Steel beam by Structural Engineer
FD30 Fire Door
L1/E 100 900mm FD30 Fire Door
L1/E 100 900mm
178x102x19UB with 2No. 203x102x23UB with 215x215x150 conc padstone
R.W.P. 300x100x150 conc padstones
Catnic CN55 2700 lintel
FD30 Fire Door 100mm step
L1/S 100 1200 lintel over
1050 Box lintel over All structural steel beams to be
encased with 2 layers 12.5mm pbd and
skim to provide 1hr fire resistance.
L1/S 100 2100 lintel over
Breakfast Porch
Mechanical extractor
60ltrs/sec air change
with 15min overrun New walls to comprise 100mm facing
bricks, 50mm clear cavity, 50mm
L1/S 100 900 lintel over Kingspan Kooltherm K8 insulation with
L1/S 100 1500 lintel over L1/S 100 2100 lintel over 100mm medium density blockwork giving
R.W.P.
B B.I.G.
A B A B A
Provide stainless steel cavity wall ties to BS1243, to suit cavity widths, spaced at max 900mm crs horiz and 450mm crs vertically,
alternative leaves staggered. Additional ties to be provided within 300mm of reveals and at 225mm crs vertically. Ties to slope towards
outer leaf. Cavities closed at reveals, cills and at eaves level. Wall ties to be suitable to take insulation retaining disc where necessary.
Ground Floor Layout First Floor Layout Second Floor Layout
B. Side extension amended and ff office added NMW 05.12
A. Structural engineers details added NMW 05.12
Rev. Description Drawn Date
16 Pilch Lane East, Huyton, Merseyside, L36 4HZ
T: 07799 061950 E: nmwdesign@gmail.com
W: nmwdesign.weebly.com
Project Title
G.S.Lander
Broseley Hall Farm
Broseley Lane
Culcheth, WA3 4HP
Drawing Title
Rear Elevation Side Elevation Front Elevation Side Elevation Proposed Plans & Elevations
Scale Drawn By Checked By Authorised By
1/50 NMWard
1/100 Date 04/12 Date Date
Job No. Drawing No. Revision
BHF/WD/02 B
Original Sheet Size A1 Do Not Scale From This Drawing