4. Principle
4
Ultrasonic measuring principle:
• Echo runtime: depth of
reflecting particles
• Echo profile characteristics:
density of reflecting particles
An ultrasonic sensor, located under the
surface of the liquid
Advantages:
• no moving parts
• never requires re-calibration
• seldom requires maintenance
5. 5
Smart signal processing for reliable sludge level measurement
raw data 🡪 signal processing 🡪 result
Easy way to ignore undesired changes of echo profile:
• Passing debris, rolling fluff, layer clouds
• Rising & falling of sludge layer due to passage of rake
Zero blanket, multiple echo situation…
Signal processing
7. 7
Calibration-free (factory calibrated) 🡪
ready-to-go
Initial effort:
• Type in sensor immersion depth and
• Tank depth
(Advanced settings for demanding applications) IFL set up
Calibration/Settings
8. Maintenance
8
Maintenance-free automatic scraper
system
•Triple sealing
•High-tech materials (titanium, grivory)
•Operate without maintenance
→ no spare parts!
• No influence of bubbles
• Removal of algae layers
(smaller layers of grease or algae do not interfere)
IFL scraper
9. Sensor positioning
9
1. Keep distance to inlet (hydraulic
effects)
2. Avoid obstacles or walls
3. Use special accessory for moving
surface skimmers (deflector)
1. 3.
2.
Tank bottom