IRCombustibleGasDetection
D12Ex-IR
GasTransmitter
Model
Infrared detection of methane
and other combustible gases is
a reliable technique that avoids
potential sensor poisoning.
In addition, IR sensors are
inherently “failsafe”, providing
fast detection of a sensor failure.
ATI’s Model D12Ex-IR provides
this IR detection capability in
an explosion-proof package
suitable for almost any
industrial environment.
D12Ex-IR transmitters provide analog signals for remote interface and
optional relays for local alarming functions. Two digital communication
options, Modbus™ and Hart™, are also available. Certified for use in
explosion hazard areas, the unit provides rapid and reliable detection of
hazardous conditions so that protective measures can be activated.
The D12Ex-IR is also available with an infrared sensor designed for CO2
measurements in ambient air or in pumped gas samples. Two carbon
dioxide sensors may be specified, one for low range use and another for
higher levels of CO2. The low range sensor may be scaled from 0-1000
PPM minimum to 0-5% maximum, while the high range sensor covers
ranges from 0-10% minimum to 0-50% maximum.
PROGRAMMED HYDROCARBONS
In addition to methane, the D12Ex-IR may be used
to monitor for a wide variety of combustible gases
and vapors. The unit is factory programmed with
response factors (K Factor) to adjust the unit for other
combustibles. You simply select the gas from the
menu contained in the transmitter. The table below
is a list of gases and vapors for which the D12Ex-IR is
factory programmed.
LEL UEL Relative K
Gas %VOL %VOL Density Factor
Acetone 2.50 12.80 1.2 3.280
Chloromethane 8.10 17.40 1.7 4.970
Cyclopentane 1.10 8.70 1.6 1.620
Dichloroethane 5.40 11.40 1.2 8.570
Ethane 3.00 12.40 1.05 1.010
Ethanol 3.30 19.00 1.6 1.650
Ethyl acetate 2.00 11.50 1.2 1.690
Ethylene 2.70 36.00 0.98 2.837
Ethylene oxide 3.00 100.00 1.5 0.845
Hexane 1.20 7.50 1.3 0.872
MEK 1.40 11.40 1.1 1.870
Methanol 6.00 36.00 1.01 2.220
n-Butane 1.60 8.40 2.11 0.970
Pentane 1.50 7.80 1.8 0.950
Propanol 2.00 12.70 1.02 1.430
Propylene 2.00 11.10 1.5 1.690
Toluene 1.10 7.10 1.01 1.180
Xylene 1.10 7.00 1.02 1.510
SENSOR SELECTION
The basic sensing element installed in the
D12Ex-IR sensor housing is selected based on the
measuring application. Four sensors are available
as follows:
HC Low level hydrocarbon sensor designed
for detecting methane, propane, and
various other flammable gases in air,
below their respective LEL. Also includes
a high range setting for monitoring
methane above its UEL.
HHC High range hydrocarbon sensor
designed for 0-100 %VOL concentrations
of Propane, Butane, LP gas and others
for monitoring levels above the UEL.
CO2-L Carbon dioxide sensor for ppm
measurement or % levels of 5% or below
CO2-H Carbon dioxide sensor for high levels
from 10% to a maximum of 50%.
IRCombustibleGasorCO2 Detection
Features
• Combustible Sensor Options for %LEL or high concentration
hydrocarbons (up to 100% V/V)
• Carbon Dioxide Sensor Options for low or high level monitoring
• Three Internal Alarm Relays for local alarm functions. All relays are
programmable for setpoint, hysteresis, on-delay, and off-delay
• Digital Communications options for either HART™ or MODBUS™ RTU.
• Backlit LCD Graphics Display shows gas concentration in large, easy to
read numbers. The display also provides alarm indication and complete
menus for setting operating parameters.
• Explosion-proof package with epoxy coated cast aluminum enclosure
and stainless steel sensor.
• Internal Data Logger stores gas values at user definable intervals. Data
can be recalled when needed on the LCD display or downloaded using an
ASCII interface to terminal or printer.
• Sensor Calibration History is stored each time a sensor is zeroed or
spanned. Calibration history can be recalled and sensor condition
reviewed whenever necessary.
• Non-intrusive Operation allows calibration, alarm setup, alarm reset,
data view, and transmitter configuration using a magnetic tool.
• Output Simulation provides easy testing of connected devices.
REMOTE SENSOR OPTION
The location of an IR sensor depends
on the density of the target gas. For
methane detection, sensors are often
located near the ceiling while detection
of heavier gases such as propane or
liquified petroleum gas (LPG) require
the sensor be mounted lower.
D12Ex-IR systems are available with
a remote sensor option for methane
applications or with an integral sensor
for heavier combustibles.
Using a remote sensor option allows the
display and control unit to be located
where it is convenient for operators.
A remote calibration adapter and fixed
tubing can be installed so that sensor
testing and calibration can be done
from floor level.
D12Ex-IR
Remote Sensor
D12 GAS TRANSMITTER
D12EX-IR
TRANSMITTER
ConduitClamps
Ceiling
1/4”oPVCFlexTubing
CalGasFeed
REMOTEIR
SENSOR
RAINSHIELD/
REMOTE
CALADAPTER
Max100’(30M)Seperation
Represented by:
AnalyticalTechnology, Inc.
6 Iron Bridge Drive
Collegeville, PA 19426
Phone 610.917.0991
Toll-Free 800.959.0299
Fax 610.917.0992
Email sales@analyticaltechnology.com
AnalyticalTechnology
Unit1&2-GateheadBusinessPark
DelphNewRoad,Delph
SaddleworthOL35DE
Phone01457873318
Fax01457874468
Emailsales@atiuk.com
Model
D12Ex-IR
(2/20)
Visit Us on the Web: www.analyticaltechnology.com
SUFFIX A – TRANSMITTER TYPE
1–Integralsensorholder,norelays
2–Integralsensorholder,withrelays
3–Remotesensorholder,norelays
4–Remotesensorholder,withrelays
SUFFIX B – DIGITAL OUTPUT
1–None				
2–MODBUS™interface		
3–HART™interface
SENSORS (Order Separately)
00-1905 HCCombustibleGas
00-1906 HHCHighHydrocarbon
00-1904 CO2-L,LowCarbonDioxide
00-1903 CO2-HHighCarbonDioxide
Accessories
60-0068 Splashguard/Remotecalibrationadapter
60-0069 SensorFlowCell/CalibrationAdapter
ORDERING INFORMATION:
MODEL D12Ex-IR –A– B
Transmitter 		
GasType: Methane:0-50/100%LEL(also0-100%V/VCH4)
CarbonDioxide:0-1000PPPM/5%or0-10/50%
HighHydrocarbons: 0-10/100%V/V
SensorType: SinglepathNon-dispersiveInfrared(NDIR)
Sensor Separation: Maximum100’cablefromremotesensortotransmitter
ResponseTime: T50 =10seconds,T90 =20seconds
Accuracy: 2%formethane,propane,CO2,andspecialorders
+/-6%rangeforHCgasesusingk-factors
Repeatability: ±1%
Zero Drift: Lessthan1%fullscalepermonth,non-cumulative
Span Drift: Dependentonenvironment,
typicallylessthan1%permonth
Analog Output: 4-20mA,600ohmsmaximumat24VDC
Digital Output: HART™(1200baudmodeminterface)
MODBUS™(1200-9600–RS232orRS485)
Power: 12–30VDC,250mAmaximum,3/4-wireconnection
Optional Relays: ThreeSPST,5A@230VACor30VDCresistive
Relay Coil: Programmableeithernormallyenergizedor
normallyde-energized.
Certifications: Class1,Div.1,GroupsB,C,&D,T6
Class1,Zone1,AExdIIBT6
IEC ExdbIICT6Gb;
ATEX II2GExdbIICT6Gb
2014/30/EU–EMCDirective
2014/35/EU–LowVoltageDirective
2014/34/EU–ATEXDirective
2011/65/EU–RoHSDirective
Temperature: -20°to+60°C
Humidity: 0-99%Non-Condensing
Weight: 7.2Lbs (2.3Kg.)
SPECIFICATIONS
Splash Guard/
Remote Cal Adapter
Flowcell/
Cal Adapter

More Related Content

Similar to ATIs-D1Ex-IR-Combustible-Gas-Transmitter-Product-Literature.pdf

SENSIT Gas Trac LZ-30 Leak Detector
SENSIT Gas Trac LZ-30 Leak DetectorSENSIT Gas Trac LZ-30 Leak Detector
SENSIT Gas Trac LZ-30 Leak DetectorDiamond Scientific
 
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec SheetDrager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Zigbee based intelligent helemet for coal miners ppt
Zigbee based intelligent helemet for coal miners pptZigbee based intelligent helemet for coal miners ppt
Zigbee based intelligent helemet for coal miners pptVenkatesh Kaduru
 
Drager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemDrager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemFlow-Tech, Inc.
 
Labguard 3D Technical brochure
Labguard 3D Technical brochureLabguard 3D Technical brochure
Labguard 3D Technical brochureNestor Martinez
 
SenseTek Stratos Modulaser Data Sheet
SenseTek Stratos Modulaser Data SheetSenseTek Stratos Modulaser Data Sheet
SenseTek Stratos Modulaser Data SheetHans Bronkhorst
 
IOT PROJE ON INDRUSTRIAL MONITORING
IOT PROJE ON INDRUSTRIAL MONITORINGIOT PROJE ON INDRUSTRIAL MONITORING
IOT PROJE ON INDRUSTRIAL MONITORINGSachin Patil
 
Monicon s500 l ir ndir gas detector
Monicon s500 l ir ndir gas detectorMonicon s500 l ir ndir gas detector
Monicon s500 l ir ndir gas detectora1-cbiss
 
Semtech NO NO2 Analyser
Semtech NO NO2 AnalyserSemtech NO NO2 Analyser
Semtech NO NO2 Analysermarkpartridge
 
VET4SBO Level 2 module 1 - unit 1 - v0.9 en
VET4SBO Level 2   module 1 - unit 1 - v0.9 enVET4SBO Level 2   module 1 - unit 1 - v0.9 en
VET4SBO Level 2 module 1 - unit 1 - v0.9 enKarel Van Isacker
 
protective helmet forCoalminers helmet
 protective  helmet forCoalminers helmet protective  helmet forCoalminers helmet
protective helmet forCoalminers helmetANILKUMAR SIVARATHRI
 
Intelligent detectors
Intelligent detectorsIntelligent detectors
Intelligent detectorsaescotom
 
E12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdf
E12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdfE12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdf
E12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdfENVIMART
 
Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...
Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...
Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...Thorne & Derrick UK
 
Crowcon IRmax Fixed Gas Detector - Spec Sheet
Crowcon IRmax Fixed Gas Detector - Spec SheetCrowcon IRmax Fixed Gas Detector - Spec Sheet
Crowcon IRmax Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
ATI_Q46PR.pdf
ATI_Q46PR.pdfATI_Q46PR.pdf
ATI_Q46PR.pdfENVIMART
 
UV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheetUV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheetENVIMART
 

Similar to ATIs-D1Ex-IR-Combustible-Gas-Transmitter-Product-Literature.pdf (20)

SENSIT Gas Trac LZ-30 Leak Detector
SENSIT Gas Trac LZ-30 Leak DetectorSENSIT Gas Trac LZ-30 Leak Detector
SENSIT Gas Trac LZ-30 Leak Detector
 
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec SheetDrager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
 
Zigbee based intelligent helemet for coal miners ppt
Zigbee based intelligent helemet for coal miners pptZigbee based intelligent helemet for coal miners ppt
Zigbee based intelligent helemet for coal miners ppt
 
Drager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection SystemDrager PointGard 2000 Series Gas Detection System
Drager PointGard 2000 Series Gas Detection System
 
IMR 7500_eng(1)
IMR 7500_eng(1)IMR 7500_eng(1)
IMR 7500_eng(1)
 
Labguard 3D Technical brochure
Labguard 3D Technical brochureLabguard 3D Technical brochure
Labguard 3D Technical brochure
 
SenseTek Stratos Modulaser Data Sheet
SenseTek Stratos Modulaser Data SheetSenseTek Stratos Modulaser Data Sheet
SenseTek Stratos Modulaser Data Sheet
 
Tx7100 smoke detector
Tx7100 smoke detectorTx7100 smoke detector
Tx7100 smoke detector
 
IOT PROJE ON INDRUSTRIAL MONITORING
IOT PROJE ON INDRUSTRIAL MONITORINGIOT PROJE ON INDRUSTRIAL MONITORING
IOT PROJE ON INDRUSTRIAL MONITORING
 
Monicon s500 l ir ndir gas detector
Monicon s500 l ir ndir gas detectorMonicon s500 l ir ndir gas detector
Monicon s500 l ir ndir gas detector
 
Semtech NO NO2 Analyser
Semtech NO NO2 AnalyserSemtech NO NO2 Analyser
Semtech NO NO2 Analyser
 
VET4SBO Level 2 module 1 - unit 1 - v0.9 en
VET4SBO Level 2   module 1 - unit 1 - v0.9 enVET4SBO Level 2   module 1 - unit 1 - v0.9 en
VET4SBO Level 2 module 1 - unit 1 - v0.9 en
 
protective helmet forCoalminers helmet
 protective  helmet forCoalminers helmet protective  helmet forCoalminers helmet
protective helmet forCoalminers helmet
 
Intelligent detectors
Intelligent detectorsIntelligent detectors
Intelligent detectors
 
E12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdf
E12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdfE12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdf
E12-15-IR-High-Level-Ammonia-Gas-Transmitter O&M.pdf
 
Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...
Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...
Patol Industrial Fire Detection 5610 ATEX & IEC EX Approved Infrared Heat Sen...
 
Crowcon IRmax Fixed Gas Detector - Spec Sheet
Crowcon IRmax Fixed Gas Detector - Spec SheetCrowcon IRmax Fixed Gas Detector - Spec Sheet
Crowcon IRmax Fixed Gas Detector - Spec Sheet
 
ATI_Q46PR.pdf
ATI_Q46PR.pdfATI_Q46PR.pdf
ATI_Q46PR.pdf
 
Eclipse manual
Eclipse manualEclipse manual
Eclipse manual
 
UV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheetUV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheet
 

More from ENVIMART

Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdfZinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdfNickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdfManganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdfLead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdfIron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdfIron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdfChromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdfCopper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdfCopper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdfCopper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdfCobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdfCadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdfArsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdfAluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdfENVIMART
 
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdfATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdfENVIMART
 
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdfATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdfENVIMART
 
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdfATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdfENVIMART
 
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdfATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdfENVIMART
 
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdfATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdfENVIMART
 
B12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdfB12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdfENVIMART
 

More from ENVIMART (20)

Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdfZinc Continuous Analysis from SEIBOLD-Wasser.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
 
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdfNickel Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
 
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdfManganese Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
 
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdfLead Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
 
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdfIron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
 
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdfIron Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
 
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdfChromium Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
 
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdfCopper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
 
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdfCopper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
 
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdfCopper Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
 
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdfCobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
 
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdfCadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
 
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdfArsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
 
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdfAluminium Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
 
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdfATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
 
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdfATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
 
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdfATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
 
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdfATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
 
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdfATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
 
B12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdfB12-2-Wire-Gas-Transmitter.pdf
B12-2-Wire-Gas-Transmitter.pdf
 

Recently uploaded

VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...Suhani Kapoor
 
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girlsMumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girlsPooja Nehwal
 
(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...
(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...
(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...ranjana rawat
 
Call Girl Nagpur Roshni Call 7001035870 Meet With Nagpur Escorts
Call Girl Nagpur Roshni Call 7001035870 Meet With Nagpur EscortsCall Girl Nagpur Roshni Call 7001035870 Meet With Nagpur Escorts
Call Girl Nagpur Roshni Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000
Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000
Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000Sapana Sha
 
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...Suhani Kapoor
 
Spiders by Slidesgo - an introduction to arachnids
Spiders by Slidesgo - an introduction to arachnidsSpiders by Slidesgo - an introduction to arachnids
Spiders by Slidesgo - an introduction to arachnidsprasan26
 
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130Suhani Kapoor
 
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...Suhani Kapoor
 
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...Cluster TWEED
 
Call Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
BOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts Services
BOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts ServicesBOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts Services
BOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts Servicesdollysharma2066
 
Environmental Toxicology (environmental biology)
Environmental Toxicology (environmental biology)Environmental Toxicology (environmental biology)
Environmental Toxicology (environmental biology)RaviPrajapat11
 
VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130
VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130
VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130Suhani Kapoor
 
(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service
(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service
(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
VIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service Gorakhpur
VIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service GorakhpurVIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service Gorakhpur
VIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service GorakhpurSuhani Kapoor
 

Recently uploaded (20)

VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Moti Ganpur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
 
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girlsMumbai Call Girls, 💞  Prity 9892124323, Navi Mumbai Call girls
Mumbai Call Girls, 💞 Prity 9892124323, Navi Mumbai Call girls
 
(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...
(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...
(NANDITA) Hadapsar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune ...
 
Call Girl Nagpur Roshni Call 7001035870 Meet With Nagpur Escorts
Call Girl Nagpur Roshni Call 7001035870 Meet With Nagpur EscortsCall Girl Nagpur Roshni Call 7001035870 Meet With Nagpur Escorts
Call Girl Nagpur Roshni Call 7001035870 Meet With Nagpur Escorts
 
Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000
Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000
Call Girls In Okhla DELHI ~9654467111~ Short 1500 Night 6000
 
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
VIP Call Girls Mahadevpur Colony ( Hyderabad ) Phone 8250192130 | ₹5k To 25k ...
 
Spiders by Slidesgo - an introduction to arachnids
Spiders by Slidesgo - an introduction to arachnidsSpiders by Slidesgo - an introduction to arachnids
Spiders by Slidesgo - an introduction to arachnids
 
Sustainable Packaging
Sustainable PackagingSustainable Packaging
Sustainable Packaging
 
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
VIP Call Girls Service Chaitanyapuri Hyderabad Call +91-8250192130
 
Call Girls In { Delhi } South Extension Whatsup 9873940964 Enjoy Unlimited Pl...
Call Girls In { Delhi } South Extension Whatsup 9873940964 Enjoy Unlimited Pl...Call Girls In { Delhi } South Extension Whatsup 9873940964 Enjoy Unlimited Pl...
Call Girls In { Delhi } South Extension Whatsup 9873940964 Enjoy Unlimited Pl...
 
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
VIP Call Girls Ramanthapur ( Hyderabad ) Phone 8250192130 | ₹5k To 25k With R...
 
Call Girls In Dhaula Kuan꧁❤ 🔝 9953056974🔝❤꧂ Escort ServiCe
Call Girls In Dhaula Kuan꧁❤ 🔝 9953056974🔝❤꧂ Escort ServiCeCall Girls In Dhaula Kuan꧁❤ 🔝 9953056974🔝❤꧂ Escort ServiCe
Call Girls In Dhaula Kuan꧁❤ 🔝 9953056974🔝❤꧂ Escort ServiCe
 
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
webinaire-green-mirror-episode-2-Smart contracts and virtual purchase agreeme...
 
Call Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Aditi Call 7001035870 Meet With Nagpur Escorts
 
BOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts Services
BOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts ServicesBOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts Services
BOOK Call Girls in (Dwarka) CALL | 8377087607 Delhi Escorts Services
 
Environmental Toxicology (environmental biology)
Environmental Toxicology (environmental biology)Environmental Toxicology (environmental biology)
Environmental Toxicology (environmental biology)
 
Call Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi Ncr
Call Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi NcrCall Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi Ncr
Call Girls In R.K. Puram 9953056974 Escorts ServiCe In Delhi Ncr
 
VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130
VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130
VIP Call Girls Service Bandlaguda Hyderabad Call +91-8250192130
 
(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service
(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service
(ZARA) Call Girls Talegaon Dabhade ( 7001035870 ) HI-Fi Pune Escorts Service
 
VIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service Gorakhpur
VIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service GorakhpurVIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service Gorakhpur
VIP Call Girl Gorakhpur Aashi 8250192130 Independent Escort Service Gorakhpur
 

ATIs-D1Ex-IR-Combustible-Gas-Transmitter-Product-Literature.pdf

  • 1. IRCombustibleGasDetection D12Ex-IR GasTransmitter Model Infrared detection of methane and other combustible gases is a reliable technique that avoids potential sensor poisoning. In addition, IR sensors are inherently “failsafe”, providing fast detection of a sensor failure. ATI’s Model D12Ex-IR provides this IR detection capability in an explosion-proof package suitable for almost any industrial environment.
  • 2. D12Ex-IR transmitters provide analog signals for remote interface and optional relays for local alarming functions. Two digital communication options, Modbus™ and Hart™, are also available. Certified for use in explosion hazard areas, the unit provides rapid and reliable detection of hazardous conditions so that protective measures can be activated. The D12Ex-IR is also available with an infrared sensor designed for CO2 measurements in ambient air or in pumped gas samples. Two carbon dioxide sensors may be specified, one for low range use and another for higher levels of CO2. The low range sensor may be scaled from 0-1000 PPM minimum to 0-5% maximum, while the high range sensor covers ranges from 0-10% minimum to 0-50% maximum. PROGRAMMED HYDROCARBONS In addition to methane, the D12Ex-IR may be used to monitor for a wide variety of combustible gases and vapors. The unit is factory programmed with response factors (K Factor) to adjust the unit for other combustibles. You simply select the gas from the menu contained in the transmitter. The table below is a list of gases and vapors for which the D12Ex-IR is factory programmed. LEL UEL Relative K Gas %VOL %VOL Density Factor Acetone 2.50 12.80 1.2 3.280 Chloromethane 8.10 17.40 1.7 4.970 Cyclopentane 1.10 8.70 1.6 1.620 Dichloroethane 5.40 11.40 1.2 8.570 Ethane 3.00 12.40 1.05 1.010 Ethanol 3.30 19.00 1.6 1.650 Ethyl acetate 2.00 11.50 1.2 1.690 Ethylene 2.70 36.00 0.98 2.837 Ethylene oxide 3.00 100.00 1.5 0.845 Hexane 1.20 7.50 1.3 0.872 MEK 1.40 11.40 1.1 1.870 Methanol 6.00 36.00 1.01 2.220 n-Butane 1.60 8.40 2.11 0.970 Pentane 1.50 7.80 1.8 0.950 Propanol 2.00 12.70 1.02 1.430 Propylene 2.00 11.10 1.5 1.690 Toluene 1.10 7.10 1.01 1.180 Xylene 1.10 7.00 1.02 1.510 SENSOR SELECTION The basic sensing element installed in the D12Ex-IR sensor housing is selected based on the measuring application. Four sensors are available as follows: HC Low level hydrocarbon sensor designed for detecting methane, propane, and various other flammable gases in air, below their respective LEL. Also includes a high range setting for monitoring methane above its UEL. HHC High range hydrocarbon sensor designed for 0-100 %VOL concentrations of Propane, Butane, LP gas and others for monitoring levels above the UEL. CO2-L Carbon dioxide sensor for ppm measurement or % levels of 5% or below CO2-H Carbon dioxide sensor for high levels from 10% to a maximum of 50%. IRCombustibleGasorCO2 Detection
  • 3. Features • Combustible Sensor Options for %LEL or high concentration hydrocarbons (up to 100% V/V) • Carbon Dioxide Sensor Options for low or high level monitoring • Three Internal Alarm Relays for local alarm functions. All relays are programmable for setpoint, hysteresis, on-delay, and off-delay • Digital Communications options for either HART™ or MODBUS™ RTU. • Backlit LCD Graphics Display shows gas concentration in large, easy to read numbers. The display also provides alarm indication and complete menus for setting operating parameters. • Explosion-proof package with epoxy coated cast aluminum enclosure and stainless steel sensor. • Internal Data Logger stores gas values at user definable intervals. Data can be recalled when needed on the LCD display or downloaded using an ASCII interface to terminal or printer. • Sensor Calibration History is stored each time a sensor is zeroed or spanned. Calibration history can be recalled and sensor condition reviewed whenever necessary. • Non-intrusive Operation allows calibration, alarm setup, alarm reset, data view, and transmitter configuration using a magnetic tool. • Output Simulation provides easy testing of connected devices. REMOTE SENSOR OPTION The location of an IR sensor depends on the density of the target gas. For methane detection, sensors are often located near the ceiling while detection of heavier gases such as propane or liquified petroleum gas (LPG) require the sensor be mounted lower. D12Ex-IR systems are available with a remote sensor option for methane applications or with an integral sensor for heavier combustibles. Using a remote sensor option allows the display and control unit to be located where it is convenient for operators. A remote calibration adapter and fixed tubing can be installed so that sensor testing and calibration can be done from floor level. D12Ex-IR Remote Sensor D12 GAS TRANSMITTER D12EX-IR TRANSMITTER ConduitClamps Ceiling 1/4”oPVCFlexTubing CalGasFeed REMOTEIR SENSOR RAINSHIELD/ REMOTE CALADAPTER Max100’(30M)Seperation
  • 4. Represented by: AnalyticalTechnology, Inc. 6 Iron Bridge Drive Collegeville, PA 19426 Phone 610.917.0991 Toll-Free 800.959.0299 Fax 610.917.0992 Email sales@analyticaltechnology.com AnalyticalTechnology Unit1&2-GateheadBusinessPark DelphNewRoad,Delph SaddleworthOL35DE Phone01457873318 Fax01457874468 Emailsales@atiuk.com Model D12Ex-IR (2/20) Visit Us on the Web: www.analyticaltechnology.com SUFFIX A – TRANSMITTER TYPE 1–Integralsensorholder,norelays 2–Integralsensorholder,withrelays 3–Remotesensorholder,norelays 4–Remotesensorholder,withrelays SUFFIX B – DIGITAL OUTPUT 1–None 2–MODBUS™interface 3–HART™interface SENSORS (Order Separately) 00-1905 HCCombustibleGas 00-1906 HHCHighHydrocarbon 00-1904 CO2-L,LowCarbonDioxide 00-1903 CO2-HHighCarbonDioxide Accessories 60-0068 Splashguard/Remotecalibrationadapter 60-0069 SensorFlowCell/CalibrationAdapter ORDERING INFORMATION: MODEL D12Ex-IR –A– B Transmitter GasType: Methane:0-50/100%LEL(also0-100%V/VCH4) CarbonDioxide:0-1000PPPM/5%or0-10/50% HighHydrocarbons: 0-10/100%V/V SensorType: SinglepathNon-dispersiveInfrared(NDIR) Sensor Separation: Maximum100’cablefromremotesensortotransmitter ResponseTime: T50 =10seconds,T90 =20seconds Accuracy: 2%formethane,propane,CO2,andspecialorders +/-6%rangeforHCgasesusingk-factors Repeatability: ±1% Zero Drift: Lessthan1%fullscalepermonth,non-cumulative Span Drift: Dependentonenvironment, typicallylessthan1%permonth Analog Output: 4-20mA,600ohmsmaximumat24VDC Digital Output: HART™(1200baudmodeminterface) MODBUS™(1200-9600–RS232orRS485) Power: 12–30VDC,250mAmaximum,3/4-wireconnection Optional Relays: ThreeSPST,5A@230VACor30VDCresistive Relay Coil: Programmableeithernormallyenergizedor normallyde-energized. Certifications: Class1,Div.1,GroupsB,C,&D,T6 Class1,Zone1,AExdIIBT6 IEC ExdbIICT6Gb; ATEX II2GExdbIICT6Gb 2014/30/EU–EMCDirective 2014/35/EU–LowVoltageDirective 2014/34/EU–ATEXDirective 2011/65/EU–RoHSDirective Temperature: -20°to+60°C Humidity: 0-99%Non-Condensing Weight: 7.2Lbs (2.3Kg.) SPECIFICATIONS Splash Guard/ Remote Cal Adapter Flowcell/ Cal Adapter