Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Lifecore implant

8,570 views

Published on

Published in: Education
  • Be the first to comment

Lifecore implant

  1. 1. Lifecore RENOVA ™Internal HexImplant SystemSurgical & Restorative Catalog
  2. 2. Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 RENOVA Implant System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 RENOVA Drill Sequence Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 RENOVA Implants RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 RENOVA Straight Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Cover Screws & Healing Abutments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Cement-Retained Restorations Cement-on-Crown (COC) Abutment System. . . . . . . . . . . . . . . . . . . . 11-13 Screw-Retained Restorations UCLA Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16 Fixed Detachable Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . 17-19 Overdenture Restorations Snap Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22 Surgical Kit for RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . 23 Surgical Instrumentation for RENOVA Tapered Implants . . . . . . . . . . . . 24-25 Surgical Kit for RENOVA Straight Implants. . . . . . . . . . . . . . . . . . . . . . . . . . 26 Surgical Instrumentation for RENOVA Straight Implants. . . . . . . . . . . . . 27-28 Additional Surgical Instrumentation for Tapered & Straight Implants . . . 29-31 Surgical Wrenches and Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33 Lab Tools and Other Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35 Lifecore LC5000 Surgical Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37 Tissue Regeneration Products Capset® Calcium Sulfate Bone Graft Barrier. . . . . . . . . . . . . . . . . . . . . . . 38 TefGen® Regenerative Membranes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Order Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-2- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  3. 3. Introduction A Leader in Biotechnology … Lifecore Biomedical is dedicated to the development of technologically advanced, dependable products that offer long-term compatibility with the human body. Thousands of patients worldwide have benefited from Lifecore’s technology in dentistry, general surgery and ophthalmology. Founded in 1965, Lifecore is a publicly held company (Nasdaq: LCBM) headquartered in Chaska, Minnesota, USA. Lifecore’s Oral Restorative Division is focused on providing the highest quality surgical devices and applications for the global dental industry. The Division offers one of the most extensive product lines to address the many clinical situations faced by our clients. Lifecore offers two-stage internal and external hex implant systems and a single stage implant system. A complete family of restorative options are available to meet the unique needs of each patient. Visit us at www.lifecore.com to learn more. Our Commitment to Quality … Lifecore’s commitment to quality and service ensures that our products meet or exceed the highest standards set by the United States Food and Drug Administration, the European Community and other international agencies. Lifecore has earned ISO 9001 and CE Certifications, international symbols of quality system assurance and compliance. Lifecore has earned a reputation for quality by enforcing strict design and inspection criteria. Our 100% inspection of all critical dimensions of dental implants and prosthetic components has allowed Lifecore to maintain the tightest tolerances in the industry. In addition, Lifecore’s Lifetime Limited Warranty gives the clinician the added security of knowing that dental implants and prosthetics are covered throughout the patient’s lifetime. Our Commitment to Your Practice … Lifecore’s technical services department is available to consult with clients on questions related to case planning, component selection and step-by-step procedures for clinical and laboratory applications. Our family of Support Plus® Restorative Training Programs are recognized in the industry as the best referral based training courses available. Lifecore is certified through the Academy of General Dentistry, the American Dental Association and through the National Board of Certification to offer continuing education credits. Lifecore is committed to being the standard of comparison for product quality, education and customer service, and to be recognized as a company of dedication, honesty and integrity. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -3-
  4. 4. RENOVA Implant System Internal hex prosthetic connection for superior esthetics and reliability 1mm machined titanium collar for soft tissue maintenance Parallel walled neck region with circumferential grooves for crestal seal and bone interlock Lifecore’s proven RBM Surface Straight and tapered designs expand treatment options Tapered design enables placement near impinging anatomical structures whileSTRAIGHT maximizing prosthetic table diameter for TAPERED natural emergence profile Apical end design provides excellent initial thread engagement and stability -4- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  5. 5. Internal Hex Prosthetic Connection Proven RBM Surface Delivers superior strength and ease Lifecore’s RENOVA, RESTORE® and STAGE-1™ of prosthetic indexability. implants feature the RBM surface. Lifecore’s RBM, a roughened titanium surface, has Beveled interface helps maximize been in clinical use since 1997 and has prosthetic stability and evenly achieved a high level of clinical acceptance. transfers occlusal forces to the implant. Lifecore’s RBM (Resorbable Blast Media) 2000X RBM Surface substantially increases bone-to-implant contact and mechanical bone interlock, with Deep internal hex connection approximately 250% more surface simplifies abutment seating and roughness than a machined titanium provides excellent tactile feel for surface. Safety and biological compatibility added confidence. are ensured through the exclusive use of biocompatible calcium phosphate ceramicRENOVA Prosthetics media in the roughening process. 500X RBM SurfaceThe Tapered and Straight implantdesigns share the same prosthetics. As a clinician, you can have confidence in the Lifecore implant you choose knowing that Lifecore is an established leader in RBM surface technology. Our three implant designs, coupled with ourThe RENOVA system offers RBM surface technology, maximize your opportunity for clinicalabutment systems for: flexibility and optimal treatment outcomes.• Cement-Retained restorations• Screw-Retained restorations Mechanical interlock of bone into the implant surface topography is evident.• Overdenture restorations A direct bone-to-implant interface is observed at 100x magnification.1 References: 1. Sanz A, et al. Experimental study of bone response to a new surface treatment of endosseous titanium implants. Implant Dentistry. 2001; 10:126-131. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -5-
  6. 6. Drill Sequence RENOVA Tapered Implants SDI 3.75mm RENOVA Tapered Implant 1 2 3 4 5 6 2.3mm Round Bur 2.0mm Initial Drill 3.75mm Intermediate Drill 3.75mm Finishing Drill 3.75mm Tap 3.75 x 13mm Implant RDI 4.5mm RENOVA Tapered Implant 1 2 3 4 5 6 2.3mm Round Bur 2.0mm Initial Drill 4.5mm Intermediate Drill 4.5mm Finishing Drill 4.5mm Tap 4.5 x 13mm Implant Depth Marking System (for Tapered Implants) 13mm NOTE: Drill stops and bands reference the insertion depth for the corresponding implant length. 0mm ≤0.36mm Initial Intermediate Finishing Tap Drill Drill Drill-6- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  7. 7. Drill Sequence ChartsDrill Sequence RENOVA Straight ImplantsSDI 3.75mm RENOVA Straight Implant 1 2 3 4 5 6 7 8 9 2.3mm 2.0mm 2.35mm 2.35mm 2.8mm Drill 3.25mm Drill 3.75mm 3.75mm Tap 3.75 x 13mm Round Bur Initial Drill Drill Depth Gauge Countersink Drill ImplantRDI 4.75mm RENOVA Straight Implant 1 2 3 4 5 6 7 8 9 10 11 2.3mm 2.0mm 2.35mm 2.35mm 2.8mm 3.25mm 3.25/4.25mm 4.25mm 4.75mm 4.75mm 4.75 x 13mmRound Bur Initial Drill Drill Depth Gauge Drill Drill Pilot Drill Drill Countersink Drill Tap ImplantDepth Marking System (for Straight Implants) 16mm 13mm 11.5mm NOTE: Drill bands reference the insertion depth 10mm for the corresponding implant length and do not 8mm indicate actual millimeter drill length. 0mm ≤1.14mm 3.25x16mm 3.25x11.5mm Drill Drill For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -7-
  8. 8. RENOVA ImplantsLifecore RENOVA Tapered Implants Features: ● Tapered implant design. ● Lifecore RBM Surface. ● Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included with each implant. ● Packaged to minimize handling during placement. ● Gamma Sterilized. Instrumentation Required: ● RENOVA Tapered Implant Surgical Kit ● .048" Hex Driver for Placement Head and Cover ScrewSDI 3.75mm RBM Tapered ImplantDescription Catalog No. 3.75mm3.75 x 10mm 140003.75 x 11.5mm 140013.75 x 13mm 14002 length3.75 x 14.5mm 14003 2.8mm Apical Diameter RDI 4.5mm RBM Tapered ImplantDescription Catalog No. 4.5mm4.5 x 8.5mm 140044.5 x 10mm 140054.5 x 11.5mm 140064.5 x 13mm 14007 length 3.0mm Apical Diameter-8- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  9. 9. Lifecore RENOVA Straight Implants Features: ● Straight (parallel walled) implant design. ● Lifecore RBM Surface. Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included Healing Abutments ● with each implant. Implants & ● Packaged to minimize handling during placement. ● Gamma Sterilized. Instrumentation Required: ❍ RENOVA Straight Implant Surgical Kit ❍ .048" Hex Driver for Placement Head and Cover ScrewSDI 3.75mm RBM Straight ImplantDescription Catalog No. 3.75mm3.75 x 8mm 130003.75 x 10mm 130013.75 x 11.5mm 130023.75 x 13mm 13003 length3.75 x 16mm 13004RDI 4.75mm RBM Straight ImplantDescription Catalog No. 4.75mm4.75 x 8mm 130054.75 x 10mm 130064.75 x 11.5mm 130074.75 x 13mm 13008 length4.75 x 16mm 13009 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -9-
  10. 10. Cover Screws & Healing AbutmentsCover Screws Features: ● Included with all RENOVA implants. ● Offered separately for spare or replacement use. Instrumentation Required: ❍ .048" Hex Driver SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Cover Screw 10032 10033Healing Abutments Features: ● Healing Abutments are designed to achieve optimal contouring of soft tissue, which provides for more aesthetic restorations. ● Occlusal surface is labeled with the implant prosthetic table (SDI and RDI) and cuff height. Instrumentation Required: ❍ .048" Hex Driver SDI 3.75mm Healing Abutment Cuff Height Catalog No. 1.5mm 10035 3mm 10036 5mm 10037 RDI 4.5/4.75mm Healing Abutment Cuff Height Catalog No. 1.5mm 10038 3mm 10039 5mm 10040-10- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  11. 11. Cement-Retained RestorationsCement-On Crown (COC) Technical Considerations: ❍ A minimum inter-occlusal clearance of 4.0mm plusAbutment System the additional height of the restoration is required between the implant prosthetic table and theFeatures: occlusal plane.● Cement-on Crown (COC) Abutments are intended ❍ It is recommended that bulk abutment reduction be for cement-retained restorations where conventional performed outside of the mouth due to risk of heat crown and bridge techniques are desired. The COC transfer to the implant. Abutment can be used for single or multi-unit (splinted) ❍ COC Abutments are made of titanium and are not restorations. designed for direct casting to the abutment.● COC Abutments can be prepared as needed and impressioned directly using conventional crown Instrumentation Required: and bridge techniques, eliminating the need for ❍ .048" Hex Driver an impression post, analog and other prosthetic components. These abutments may also be used for provisional (temporary) restorations. Torque Recommendation: ❍ 30 Ncm for Abutment Screw ProstheticsLaboratory .048” Hex Driver 15° Angled Straight Locking COC Abutment COC Abutment Implant Analog Implant ImpressionProsthetic 15° Angled Straight Locking COC Abutment COC Abutment Post (Hexed) Abutment Implant Impressioned Directly Impressioned Directly Healing AbutmentSurgery Tapered Implant Straight Implant For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -11-
  12. 12. Cement-Retained RestorationsStraight Locking Cement-On Crown (COC) Abutments ● For use in single or multi-unit (splinted) restorations. ● Abutment margin can be prepared as necessary to follow gingival contours. ● COC Abutment may be impressioned directly using conventional crown and bridge impression techniques. Alternately, a locking implant impression post can be used to impression the Implant; allowing the laboratory to prepare the abutment and fabricate the restoration. ● Abutments include .048” hex titanium abutment screw. Additional screws are available separately. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. COC Abutment with Screw 43089 43090 Abutment Screw, Ti 43092 43092Angled Locking Cement-On Crown (COC) Abutments ● For use in single or multi-unit (splinted) restorations where angle correction is needed. ● Pre-machined margins simplify abutment preparation and may be additionally prepared to follow gingival contours. ● COC Abutment may be impressioned directly using conventional crown and bridge impression techniques. Alternately, a locking implant impression post can be used to impression the implant; allowing the laboratory to prepare the abutment and fabricate the restoration. ● Abutments include .048” hex titanium abutment screw. Additional screws are available separately. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 15°, 2mm Cuff 43094 43096 Abutment Screw, Ti 43100 43100-12- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  13. 13. Implant Impression Posts (UCLA type) ● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a long screw (open tray impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Impression Post 43127 43128Implant Analogs ● Replicates the implant for use in the dental laboratory model. Prosthetics ● Stainless steel design allows use during soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Analog 43129 43130 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -13-
  14. 14. Screw-Retained RestorationsUCLA Abutment System Technical Considerations: ❍ A minimum inter-occlusal clearance of 4.0mmFeatures: for the SDI and RDI UCLA Abutments is required● The UCLA Abutment System can be used for single or between the implant prosthetic table and the top multi-unit (splinted) crown and bridge restorations. It of the abutment screw when seated. can also be used for bar attachment retained overdenture restorations. Instrumentation Required: ❍ .048” Hex Driver● UCLA Abutments are used to fabricate highly aesthetic custom restorations that attach directly Torque Recommendation: to the implant. ❍ 30 Ncm for Abutment Screws .048” Hex DriverLaboratory UCLA Gold/Plastic UCLA UCLA UCLA Sleeve (Locking) Temporary Temporary Gold/Plastic Sleeve Sleeve Sleeve (Locking) (Non- (Non-Locking) Locking) Implant AnalogProsthetic Implant Implant Impression Post Impression Post Single Unit Multi-Unit (Splinted) Restorations Restorations Healing AbutmentSurgery Tapered Implant Straight Implant-14- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  15. 15. UCLA Gold/Plastic Combo Sleeve ● The Gold/Plastic Combo combines the precision fit of a machined interface with the convenience of a castable plastic chimney. ● Specially designed geometry on the plastic chimney improves wax retention. ● Offered in both locking and non-locking versions. ● Includes a titanium .048” hex abutment screw. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Locking 43006 43007 Non-Locking 43009 43010 ProstheticsAbutment Screws for ● Titanium screw included with each abutment and offered separately.UCLA Abutments ● .048” hex. ● Torque recommendation – 30Ncm. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Abutment Screw, Ti 43116 43116 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -15-
  16. 16. Implant Impression Posts (UCLA type) ● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a .048” hex long screw (open tray impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Impression Post 43127 43128Implant Analogs ● Replicates the implant for use in the dental laboratory model. ● Stainless steel design allows use during soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Analog 43129 43130UCLA Temporary Sleeve ● Titanium Temporary Sleeves provide a textured surface for acrylic when constructing provisional restorations. ● Available in non-hexed for multi-unit (splinted) restorations and hexed for single tooth restorations. ● Includes a titanium .048" hex abutment screw. SDI 3.75mm* RDI 4.5/4.75mm* Description Catalog No. Catalog No. Sleeve, Hexed 43110 43111 Sleeve, Non-Hexed 43113 43114 *Call for availability-16- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  17. 17. Screw-Retained Restorations Fixed Detachable Abutment System Features: ● The Fixed Detachable Abutment System is designed for ❍ A minimum inter-occlusal clearance of 6.9mm is multi-unit (splinted) crown and bridge restorations. required between the implant prosthetic table and the ● It is also commonly used for bar attachment retained top of the coping screw when seated. overdenture restorations. ❍ The tapered 12° side wall allows up to 24° of ● The Fixed Detachable Abutment provides excellent divergence between adjacent abutments. stability and allows for easier path of insertion due to its tapered design. Instrumentation Required: ❍ .062” Hex Driver Technical Considerations: Prosthetics .048" Hex DriverLaboratory Coping Screw (.048" Hex) Fixed Waxing Fixed Detachable Pin Detachable Plastic Sleeve Gold Sleeve Fixed Detachable Abutment AnalogProsthetic 1-Piece Impression Post 2-Piece Multi-Unit (Splinted) .048" Impression Post Hex Driver Restorations Healing Fixed .062" Hex Cap Detachable Driver Abutment AC Healing AbutmentSurgery Regular Diameter (RD) components shown Components not shown to scale. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -17-
  18. 18. Screw-Retained RestorationsFixed Detachable Abutments ● Torque recommendation – 30Ncm. Instrumentation required: cuff ● .062" Hex Driver. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 2mm Cuff, .062" Hex 43118 43120 4mm Cuff, .062" Hex 43119 43121Healing Cap for Fixed Detachable Abutments ● Protects the abutments internal threads and seating surface during healing. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No Catalog No. Healing Cap, .048" Hex R2800-00 R2800-00Impression Posts for Fixed Detachable Abutments ● 1-piece design is used for closed tray impressions. ● 2-piece design is used for open tray impressions. Impression Post, 1-Piece SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 1-Piece, 9mm, .048" Hex R9615-48 R9615-48 2-Piece, 9mm, .048" Hex R9515-48 R9515-48 Impression Post, 2-Piece-18- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  19. 19. Analog for Fixed Detachable Abutments ● Replicates the Fixed Detachable Abutment for use by the dental laboratory. ● Stainless steel design allows use during laboratory soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Fixed Detachable Analog 410530-4 410530-4Gold Sleeve and Plastic Sleeve for Fixed Detachable Abutments ● Gold Sleeve provides a precision machined interface between the restoration and the abutment. A Waxing Pin Prosthetics is available for waxing additional vertical height. ● Plastic Sleeve provides an economical alternative to Gold Cylinders and the extended chimney eliminates the need for a Waxing Pin. Gold Sleeve Plastic Sleeve ● Use with titanium coping screws, which are purchased separately. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Gold Sleeve 410720-4 410720-4 Plastic Sleeve, 12mm 410450-4L 410450-4L Waxing Pin R9229-48 R9229-48Coping Screw for Fixed Detachable Abutments ● Use with Fixed Detachable Abutment Gold and Plastic Sleeves. ● Torque recommendation - 20Ncm. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. .048" Hex (1.5mm head) R9490-48 R9460-48 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -19-
  20. 20. Overdenture Restorations Snap Abutment System Features: ● The Snap Abutment System is used with two or more implants for implant attachment retained overdenture restorations. ● The Snap Abutment threads directly into the implant. ● The Snap Abutment assembly is processed into the denture base either chairside or at the dental laboratory. ● Replacement retention inserts are available in a choice of 8, 10 and 12 Newtons. Technical Considerations: ❍ A minimum inter-occlusal clearance of 7.0mm plus the cuff height is required. ❍ Implants must be relatively parallel to one another – less than 20º total divergence. Snap Abutment Assembly Overdenture Snap Abutment Driver Laboratory Abutment Implant Analog Snap Abutment Assembly Implant Prosthetic Impression Post Snap Abutment Abutment Analog Overdenture .048” Hex Driver Abutment Driver Abutment Implant Impressioned Directly Impressioned Directly Healing Abutment Surgery Tapered Implant Straight Implant-20- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  21. 21. Snap Abutments ● Snap Abutments are packaged with a Snap Abutment Assembly [8 Newtons (N) – yellow] and laboratory spacer. ● Torque Recommendation – 30Ncm. Snap Abutment Assembly Instrumentation Required: ❍ Overdenture Abutment Driver cuff SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Snap Abutment 1mm Cuff 43102 43106 2mm Cuff 43103 43107 3mm Cuff 43104 43108 4mm Cuff 43105 43109Snap Abutment Accessories Snap Abutment Assembly 8N Description Catalog No. Retaining Retention Abutment Analog L2804-01 Ring Insert Snap Retention Inserts, 8N, 10 N Qty 6 (includes blue retaining rings) L2806-08 Snap Retention Inserts, 10N, Retaining Retention Qty. 6 (includes blue retaining rings) L2806-10 Instrumentation & Motor Ring Insert Snap Retention Inserts, 12N, 12 N Qty. 6 (includes blue retaining rings) L2806-12 Retaining Retention Snap Retention Inserts, Multi-Pack, Ring Insert Qty. 6 (includes blue retaining rings) L2806-13 Assembly (8N) with lab spacer L2807-01 Seating Tool L2808-01Abutment Seating Analog Tool For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -21-
  22. 22. Implant Impression Posts (UCLA type) ● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a .048" hex long screw (open tray impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Impression Post 43127 43128Implant Analogs ● Replicates the implant for use in the dental laboratory model. ● Stainless steel design allows use during soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Analog 43129 43130-22- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  23. 23. Surgical Kit for RENOVA Tapered Implants The RENOVA Tapered Implant Surgical Kit contains the instrumentation needed to place RENOVA 3.75 and 4.5mm tapered implants. Kit Features: ● Simple step-by-step drill sequences. ● RENOVA instrumentation offers improved efficiency, longevity and overall ease of use. ● Includes drills and taps for use with external irrigation.Description Catalog No.Surgical Kit for Tapered Implants 14012Surgical Kit Item List:2.3mm Round Marking Bur 3.75 x 11.5mm Surgical Tap .048" Hex Swivel Head Driver, Long2.0mm Initial Drill 3.75 x 13mm Surgical Tap .048" Hex Driver, Latch-Type, Short3.75 x 10mm Intermediate Drill 3.75 x 14.5mm Surgical Tap Conversion Handle for3.75 x 11.5mm Intermediate Drill 4.5 x 8.5mm Surgical Tap Latch-Type Instruments3.75 x 13mm Intermediate Drill 4.5 x 10mm Surgical Tap Ratchet Extender, Short & Long Placement Head Assembly Sleeves,3.75 x 14.5mm Intermediate Drill 4.5 x 11.5mm Surgical Tap SDI & RDI3.75 x 10mm Finishing Drill 4.5 x 13mm Surgical Tap Component Pack3.75 x 11.5mm Finishing Drill SDI 3.5mm NP Placement Head Instrumentation & Motor Grommet Plugs, 2 Packs of 103.75 x 13mm Finishing Drill SDI 5.5mm NP Placement Head Cleaning Detergent3.75 x 14.5mm Finishing Drill RDI 3.5mm NP Placement Head4.5 x 8.5mm Intermediate Drill RDI 5.5mm NP Placement Head4.5 x 10mm Intermediate Drill SDI 15mm NP Placement Head*4.5 x 11.5mm Intermediate Drill RDI 15mm NP Placement Head*4.5 x 13mm Intermediate Drill Locking Drill Extender4.5 x 8.5mm Finishing Drill Surgical Ratchet4.5 x 10mm Finishing Drill Stabilizing Wrench4.5 x 11.5mm Finishing Drill Hand Adapter4.5 x 13mm Finishing Drill Ratchet Adapter, 8mm3.75mm Countersink Drill, Tapered Ratchet/Tap Adapter, 12mm4.5mm Countersink Drill, Tapered Handpiece Adapter3.75 x 10mm Surgical Tap .048" Hex Swivel Head Driver, Short* Call for availability For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -23-
  24. 24. Surgical Instrumentation for RENOVA Tapered ImplantsFor recommended drill sequences and details on drill depth markings, refer to page 6.Round Bur & Initial Drill ● Round Bur is used for marking the implant site prior to beginning the drilling sequence. ● Initial Drill is the first drill used for all RENOVA Tapered Implants. Description Catalog No. Round Bur Round Marking Bur, 2.3mm L1405-23-00 2.0mm Initial Drill 14071 Initial DrillDrills for RENOVA Tapered● Specific drill is used for each implant size.● For use with external irrigation. SDI 3.75mm Tapered Intermediate Drills SDI 3.75mm Tapered Finishing Drills Description Catalog No. Description Catalog No. 3.75 x 10mm 14072 3.75 x 10mm 14076 3.75 x 11.5mm 14073 3.75 x 11.5mm 14077 3.75 x 13mm 14074 3.75 x 13mm 14078 3.75 x 14.5mm 14075 3.75 x 14.5mm 14079 RDI 4.5mm Tapered Intermediate Drills RDI 4.5mm Tapered Finishing Drills Description Catalog No. Description Catalog No. 4.5 x 8.5mm 14080 4.5 x 8.5mm 14084 4.5 x 10mm 14081 4.5 x 10mm 14085 4.5 x 11.5mm 14082 4.5 x 11.5mm 14086 4.5 x 13mm 14083 4.5 x 13mm 14087-24- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  25. 25. Surgical Taps for RENOVA Tapered Implants ● For pre-tapping bone prior to tapered implant placement. ● Latch-type tap can be used in a handpiece or can be operated manually when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap Adapter (L1806-05). SDI 3.75mm Tapered Surgical Tap Description Catalog No. 3.75 x 10mm 14088 3.75 x 11.5mm 14089 3.75 x 13mm 14090 3.75 x 14.5mm 14091 Instrumentation & Motor RDI 4.5mm Tapered Surgical Tap Description Catalog No. 4.5 x 8.5mm 14092 4.5 x 10mm 14093 4.5 x 11.5mm 14094 4.5 x 13mm 14095 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -25-
  26. 26. Surgical Kit for RENOVA Straight Implants The RENOVA Straight (parallel walled) Implant Surgical Kit contains the instrumentation needed to place RENOVA 3.75 and 4.75mm straight implants. Kit Features: ● Simple step-by-step drill sequences. ● RENOVA instrumentation offers improved efficiency, longevity and overall ease of use. ● Includes drills and taps for use with external irrigation.Description Catalog No.Surgical Kit for Straight Implants 13010Surgical Kit Includes:2.3mm Round Marking Bur 2.35mm Depth Gauge Conversion Handle for Latch-Type2.0mm Initial Drill SDI 3.5mm NP Placement Head Instruments2.35 x 11.5mm Drill SDI 5.5mm NP Placement Head Ratchet Extender, Short & Long Placement Head Assembly Sleeves,2.35 x 16mm Drill RDI 3.5mm NP Placement Head SDI & RDI2.8 x 11.5mm Drill RDI 5.5mm NP Placement Head Component Pack2.8 x 16mm Drill SDI 15mm NP Placement Head* Grommet Plugs, 2 Packs of 103.25 x 11.5mm Drill RDI 15mm NP Placement Head* Cleaning Detergent3.25 x 16mm Drill Locking Drill Extender3.25/4.25mm Pilot Drill Surgical Ratchet4.25 x 11.5mm Drill Stabilizing Wrench4.25 x 16mm Drill Hand Adapter3.75mm Countersink Drill Ratchet Adapter, 8mm4.75mm Countersink Drill Ratchet/Tap Adapter, 12mm3.75 x 11.5mm Surgical Tap Handpiece Adapter3.75 x 16mm Surgical Tap .048" Hex Swivel Head Driver, Short4.75 x 11.5mm Surgical Tap .048" Hex Swivel Head Driver, Long4.75 x 16mm Surgical Tap .048" Hex Driver, Latch-Type, Short* Call for availability-26- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  27. 27. Surgical Instrumentation for RENOVA Straight ImplantsFor recommended drill sequences and details on drill depth markings, refer to page 7.Round Bur & Initial Drill ● Round Bur is used for marking the implant site prior to beginning the drilling sequence. ● Initial Drill is the first drill used for all RENOVA Straight Implants. Description Catalog No. Round Marking Bur, 2.3mm L1405-23-00 Round Bur Initial Drill 2.0mm Initial Drill 14071Drills for RENOVA Straight ImplantsInitial Drills ● ● For use with external irrigation. Offered in 2 lengths. Short – for RENOVA straight implants up to 11.5mm Long – for RENOVA straight implants up to 16mm Description Catalog No. 2.35 x 11.5mm Drill 13031 2.35 x 16mm Drill 13032Intermediate & Finishing Drills Instrumentation & Motor Description Catalog No. 2.8 x 11.5mm Drill 13033 2.8 x 16mm Drill 13034 3.25 x 11.5mm Drill 13035 3.25 x 16mm Drill 13036 4.25 x 11.5mm Drill 13038 4.25 x 16mm Drill 13039Pilot Drill ● Pilot Drill helps ensure a smooth and accurate transition between the 3.25mm and 4.25mm drills. ● For use with external irrigation. Description Catalog No. 3.25/4.25 Pilot Drill 13037Countersink Drills ● Contours ridge prior to placing 3.75mm and 4.75mm RENOVA Straight Implants, allowing implant and cover screw placement at or below the surrounding bone level. ● For use with external irrigation. Description Catalog No. 3.75mm Countersink Drill 13040 4.75mm Countersink Drill 13041 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -27-
  28. 28. Surgical Instrumentation forRENOVA Straight ImplantsSurgical Taps for RENOVA Straight Implants ● For pre-tapping bone prior to implant placement. ● Latch-type tap can be used in a handpiece or can be operated manually when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap Adapter (L1806-05). ● For use with external irrigation. ● Offered in 2 lengths. Short – for RENOVA straight implants up to 11.5mm Long – for RENOVA straight implants up to 16mm SDI 3.75 Straight Surgical Taps Description Catalog No. 3.75 x 11.5mm Tap 13042 3.75 x 16mm Tap 13043 RDI 4.75 Straight Surgical Taps Description Catalog No. 4.75 x 11.5mm Tap 13044 4.75 x 16mm Tap 13045-28- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  29. 29. Additional Surgical Instrumentationfor Tapered and Straight ImplantsDepth Gauge ● Verifies depth of the surgical site. ● Depth marks correspond to implants lengths. Description Catalog No. 2.35mm Depth Gauge (for straight implants) 10589Parallel Pins ● Used as a visual guide during surgery to help ensure parallel implant placement. Description Catalog No. 2.0mm Parallel Pin (tapered & straight implants), 2-pk 10028* 2.35/2.8mm Parallel Pin (straight implants), 2-pk 13029*Surgical Ratchet, Adapter and Extenders Description Catalog # ● Ratchet is used for manual operation of the Surgical Taps and/or final tightening of the implant. Surgical Ratchet L1702-01 ● Ratchet Extenders enable clearance of adjacent teeth. Ratchet Adapter, 8mm L1806-04 (for NP Placement Heads) Instrumentation & Motor Ratchet/Tap Adapter, 12mm L1806-05 (for NP Placement Heads & Surgical Ratchet Latch-Type Surgical Taps) Ratchet Extender, Short & Long L1703-01 (to extend the Ratchet Adapters) Replacement O-Rings for L1806-03 Ratchet Adapter, Qty. 4 NP Ratchet Adapters Ratchet ExtendersNarrow Profile (NP) ● Narrow design improves intra-oral access during implant placement. ● Color anodized for easy identification of implant/placement head junction.Placement Heads ● External flats correspond to the flats of the implants internal hex for easy indexing. Instrumentation Required: ❍ .048" Hex Driver SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 3.5mm Placement Head 10585 10587 5.5mm Placement Head 10586 10588 15mm Placement Head 10579* 10580* * Call for availability For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -29-
  30. 30. Direct-to-Implant ● Connects directly to RENOVA Tapered and Straight Implant prosthetic connections for adjusting implant insertion depth during first stage surgery.Ratchet Adapters ● Used in conjunction with the Surgical Ratchet. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Adapter, short 10590 10592 Adapter, long 10591 10593 Stabilizing Wrench ● ● For use only with Narrow Profile (NP) Placement Heads. Use open or closed end to stabilize the implant during loosening of the placement head screw. ● Features a special pin to engage the Ratchet Adapter (L1806-04) and stabilize the implant during manual placement. Description Catalog No. Stabilizing Wrench L1709-01Handpiece ● Inserts into the handpiece and connects to the RENOVA NP PlacementPlacement Adapter Head for motor driven implant placement. Description Catalog No. Handpiece Adapter (for NP placement heads) L1406-01Hand Adapter for ● Connects to the RENOVA NP Placement Head and carries the implant to the surgical site for hand delivered implant placement.Narrow Profile (NP) ● Can also be used to remove the placement head by inserting a hexPlacement Head driver through the top end to loosen the screw and then carry the placement head assembly out of the mouth. Description Catalog No. Hand Adapter (for NP placement heads) L1406-02-30- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  31. 31. Titanium Forceps ● Titanium Forceps are used to handle implants and other titanium components to avoid possible contamination. Description Catalog No. Titanium Forceps R9119Locking Drill Extender ● Adds 17mm of length to any latch-type drill or driver. ● Useful when drilling next to adjacent teeth. Description Catalog No. Locking Drill Extender L1404-01Implant Sizing Overlays ● Use these transparent overlays with radiographs for pre-surgical assessment and implant selection. ● 100% (1:1) Sizing Overlay for use with peri-apical x-rays. ● 125% Sizing Overlay for panoramic radiographs. Instrumentation & Motor Description Catalog No. Tapered Implant 100% (1:1) Sizing Overlay 14050* Tapered Implant 125% Sizing Overlay 14051* Straight Implant 100% (1:1) Sizing Overlay 13027* Straight Implant 125% Sizing Overlay 13028* * Call for availability For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -31-
  32. 32. Wrenches and Drivers Accu-Torque Wrenches & Accessories 20Ncm Torque Wrench ● Pre-calibrated wrenches precisely deliver proper torque. ● Use with Accu-Torque Drivers. ● Conversion Handle allows use of Accu-Torque Drivers as hand drivers. 30Ncm Torque Wrench Description Catalog No. Accu-Torque Wrench, 20Ncm ISS1101 Accu-Torque Wrench, 30Ncm ISS1102 Conversion Handle for Conversion Handle for Accu-Torque Drivers, Swivel Head ISS1112 Accu-Torque Drivers Replacement O-Rings for Accu-Torque Drivers, Qty 6 ISS1111Torque Wrench Care and MaintenanceCleaning and Sterilization:● Before initial use and after each procedure, clean the torque wrench with a wet towel or disinfectant wipe. Rinse under warm tap water and wipe dry.● Before sterilization, spray an approved (handpiece type) instrument lubricant into the opening at the back of the wrench.● Sterilize with the handle in the broken position.● Wrench may be sterilized by steam autoclave. Do not exceed 125°C (257°F).● Always use the dry cycle.● Do not use “Flash Sterilization” techniques.● After sterilization, reset the torque break handle, then manually “break” the hinge again to ensure the wrench is operating correctly.Calibration:For proper function and accurate control, Accu-Torque Wrenches should be calibrated every 6 months (or after 100autoclave cycles). For calibration or repair, wrenches should be sent directly to:Micromotor Repair Station151 East Columbine AvenueSanta Ana, CA 92707 USA800-562-6204Outside the U.S.: 714-546-4045* For Lifecore’s Torque Wrench warranty information, please reference the Ordering & Warranty Information section on page 37.-32- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  33. 33. .048" Hex Drivers ● Use with .048" hex placement head screws, healing abutments, abutment screws and impression posts. ● Tapered hex tip allows screws to be carried to the implant site. Description Catalog No. .048" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length) R9121 .048" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length) R9122 .048" Hex Driver, Latch-Type, Short (23mm total length) L1400-48-23 Hex Latch Type Accu- .048" Hex Driver, Latch-Type, Long (28mm total length) L1400-48-28 Driver Driver Torque Driver .048" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft) ISS1104 .048" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft) ISS1109.062" Hex Drivers ● Used for Fixed Detachable Abutments. ● Tapered hex tip allows abutments to be carried to the implant site. Description Catalog No. .062" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length) L2100-62-19 .062" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length) L2100-62-24 .062" Hex Driver, Latch-Type, Short (23mm total length) L1400-62-19 .062" Hex Driver, Latch-Type, Long (28mm total length) L1400-62-23 Instrumentation & Motor Swivel Latch- Accu- Head Type Torque Driver Driver Driver .062" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft) ISS1119 .062" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft) ISS1120Overdenture ● Used for Snap Abutments.Abutment Drivers Description Catalog No. Overdenture Driver, Swivel Head (8mm shaft) L2100-96-19 Overdenture Driver, Latch-Type (20mm total length) L1404-96-20 Overdenture Driver, for Accu-Torque Wrench* (8mm shaft) L2101-96-16 Swivel Latch Accu- Head Type Torque Driver Driver Driver For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -33-
  34. 34. Lab Tools & Other Products Hader Bar and Clip System ● A simple, effective bar system, featuring a plastic bar pattern and nylon clips, which are processed into the removable prosthesis. ● Mechanical snap retention. Hader Castable Bar Description Catalog No. Hader Hader Castable Bar And Clip System ISS185H Processing Clip (includes 1 Hader Bar, 6 Processing Clips, 6 Final Clips & 1 Hader Tool) Hader Hader Castable Bar ISS185B Final Clip Hader Processing Clips, Qty. 6 ISS185HP Hader Final Clips, Qty. 6 ISS185HR Hader Metal Hader Clip Metal Housings, Qty. 6 ISS526H Housing Clip Hader Tool ISS185T Hader Tool-34- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  35. 35. Component Pack ● Organizes small components such as the implant cover screws, placement heads, etc. ● Autoclavable design with slide lid interlocks into the base of the surgical kits. ● Optionally, may be used as a stand-alone organizer. Description Catalog No. Component Pack L1812-01 Instrument Cleaning Detergent • For use with all Lifecore instruments and surgical kits. • Includes recommended cleaning instructions. Cleaning Detergent L1819-01 Instrumentation & Motor For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -35-
  36. 36. LC5000 Surgical Motor System LC5000 Features: Lifecore’s LC5000 is a simple, user-friendly motor with abundant features for implantology and oral and maxillofacial microsurgery. Carefully designed features, place the LC5000 in a class of its own. The unique motor with large on-screen graphics display, straight- forward console layout, foot pedal control and Program/Patient Information Smart Cards exemplifies high performance. Since the LC5000 is manufactured specifically for Lifecore Biomedical, it comes complete with Lifecore’s surgical protocol preprogrammed and is backed by a full one-year warranty. In addition, the compact design helps maximize surgical work area. ● Compact design helps maximize surgical work area ● Large, easy-to-read display clearly identifies motor settings including procedure, rpm, torque, irrigation flow rate, etc. ● Unique foot pedal design with large buttons simplifies access to functions during surgery. Also provides variable speed control. ● A versatile 20:1 handpiece can be used for drilling, tapping and implant placement (sold separately). ● Torque Bar display provides a visual reference of torque delivered during procedures. ● Program Data Smart Card instantly saves/retrieves up to 20 custom program settings. ● Patient Data Smart Card & PC Software stores patient information for documenting patient treatment data. ● Auto-Calibration function for motor/handpiece enables superior rpm and torque control. ● Full one-year warranty included. Extended warranty options also available. Contact Lifecore Client Service or your sales representative for more details.Lifecore LC5000 Surgical Motor System PackageDescription Catalog #LC5000 Surgical Motor and Console 1059420:1 Handpiece 1059510-pack of Sterile Irrigation Tubing 10598Testing Gauge for Latch-Type Instrument Shanks 10602PC Software Updating Kit 10611Service Oil, 50ml* 10604-36- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  37. 37. Lifecore LC5000 Surgical Motor AccessoriesDescription Catalog #LC5000 Surgical Motor Unit 1059420:1 Reduction Contra-Angle Handpiece - for implant surgery(up to 150,000 rpm when used with LC5000 Motor) 105951:1 High Speed Straight Handpiece(up to 30,000 rpm when used with LC5000 Motor) 105961:5 High Speed Straight Handpiece(up to 30,000 rpm when used with LC5000 Motor) 10597Irrigation Tubing, Sterile, 10-pack 10598Irrigation Needle, 2-pack 10599Y-Connector, 2-pack 10600Y-Tubing, 2-pack 10601Testing Gauge (for latch-type instrument shanks) 10602Travel Case (for LC5000 Motor System) 10603Service Oil, 50ml* 10604Service Oil, 250ml (6-pack)* 10613 Instrumentation & MotorSterilization Protector for Motor 10607Sterilization Case 10606Patient Data Smart Card, 1-pack (for LC5000) 10608Program Data Smart Card, 1-pack (for LC5000) 10609System Software Card, 1-pack (for LC5000) 10610PC Software Updating Kit 10611USB Cable Adapter 10612*Due to aerosol service oil can, special shipping and handling is required. Please contact Client Service for shipping rates. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -37-
  38. 38. Tissue Regeneration Products ® CAPSET Calcium Sulfate Bone Graft Barrier CAPSET Calcium Sulfate Bone Graft Barrier is a barrier designed to be used over bone grafting material to aid bone regeneration. Each CAPSET kit contains proprietary formulation calcium sulfate and an accelerating solution. When mixed together, they form a paste, which is molded into place over bone grafting material. CAPSET Features: • Bioresorbable • Conforms to Defect • Easy to Use • Positive Tissue Response • Offers Longer Working Time (SlowSet) • Ideal for Multiple Defects (SlowSet) The 0.25gm reserve cup of calcium sulfate can act as a binder when mixed with Bone Allograft, Autogenous Bone, Xenografts or Synthetic Bone grafting material. • Improves handling properties • Reduces particle migration Description Catalog # CAPSET 1.0gm 4061-10 CAPSET 2.0gm 4061-20 CAPSET SlowSet 1.0gm 4064-10 CAPSET SlowSet 2.0gm 4064-20 0.25gm Reserve Cup, 6-Pack 4061-025-38- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300

×