DESIGN STUDIO III ARCP 301
R. Belton, AIA, NOMA, CSI Associates Professor
PROBLEM 1
FALL 2018
COMMERCIAL GROUND FLOOR AND OFFICE BUILDING
8/22/2018
Ralph Belton, AIA
Table of Contents
I. INTRODUCTION3
A. Preamble3
B. Program3
II. PROJECT STATEMENT3
III. SITE AND ENVIRONMENTAL DATA3
A. Climate and Geographical Data3
B. Adjacencies and Zoning4
C. Topography4
D. Major View4
E. Utilities4
F. Soil and Sub-Surface Conditions4
IV. PROGRAM REQUIREMENTS5
A. General Requirements5
B. Site Requirements5
C. Building Requirements5
V. CODE REQUIREMENTS7
A. General7
B. Classifications7
C. Exiting Requirements7
D. Occupant Load8
E. Stairs8
F. Fire Ratings8
G. Barrier-Free Design9
APPENDIX A11
Required Drawings11
Grading Criteria12
APPENDIX B13
APPENDIX C14
APPENDIX D15
APPENDIX E16
RECREATIONAL RETIAL MALL AND OFFICE BUILDING
I. INTRODUCTION
A. Preamble
The District of Columbia has embarked on an ambitious city planning scheme to reshape the city scape to accommodate the younger generation interested in compact activity zone were shopping recreation and work all happen in close proximity. In part this phenomena is driven by the baby boomers who has a age factor that make living and entertainment in the close proximity a necessity of life. The options for boomers are suburban senior homes or an urban area with all the needed amenities within reach. Transportation access is also important for both groups.
So the city Mixed Use (MU) … “zones are designed to provide facilities for housing, shopping, and business needs, including residential, office, service, and employment centers.”
B. Program
XYZ Corporation has acquired a 2.4 acre parcel of land on the Connecticut Ave corridor in North West Washington DC. (See subdivision record plat Appendix B). In partnership with the Giant Corp., the company intends to develop a mixed use building to include retail and office activities on the land in keeping with the Washington DC Connecticut Ave corridor urban plan. The project is envisioned to conform to the implementation of the Comprehensive Plan.
II. PROJECT STATEMENT
With the influx genXers, Milennials, and an establish population of professional and elderly people[footnoteRef:1] the XYZ Corporation has determined through market studies that this site will support a retail and office building. [1: http://apps.urban.org/features/OurChangingCity/demographics/index.html#index ]
XYZ Corporation recognizes the business advantage of locating its branch offices in close proximity to several Universities and on the metro red line. As a result the corporation has assembled a strategic parcel of land on Connecticut Ave NW adjacent to the Metro line. (See also Appendix B.)
III. SITE AND ENVIRONMENTAL DATA
A. Climate and Geographical Data
1. Location:Latitude 38° 57' N
Longitude 77° 1' W
2. Elevation at Building Site: 322.0 feet above sea level.
3. Sun Angles:December 21st at Noon 28.55°
June 21st at Noon 75.45°
4.
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
DESIGN STUDIO III ARCP 301R. Belton, AIA, NOMA, CSI Associates.docx
1. DESIGN STUDIO III ARCP 301
R. Belton, AIA, NOMA, CSI Associates Professor
PROBLEM 1
FALL 2018
COMMERCIAL GROUND FLOOR AND OFFICE BUILDING
8/22/2018
Ralph Belton, AIA
Table of Contents
2. I. INTRODUCTION3
A. Preamble3
B. Program3
II. PROJECT STATEMENT3
III. SITE AND ENVIRONMENTAL DATA3
A. Climate and Geographical Data3
B. Adjacencies and Zoning4
C. Topography4
D. Major View4
E. Utilities4
F. Soil and Sub-Surface Conditions4
IV. PROGRAM REQUIREMENTS5
A. General Requirements5
B. Site Requirements5
C. Building Requirements5
V. CODE REQUIREMENTS7
A. General7
B. Classifications7
C. Exiting Requirements7
D. Occupant Load8
E. Stairs8
F. Fire Ratings8
G. Barrier-Free Design9
APPENDIX A11
Required Drawings11
Grading Criteria12
APPENDIX B13
APPENDIX C14
APPENDIX D15
APPENDIX E16
RECREATIONAL RETIAL MALL AND OFFICE BUILDING
I. INTRODUCTION
3. A. Preamble
The District of Columbia has embarked on an ambitious city
planning scheme to reshape the city scape to accommodate the
younger generation interested in compact activity zone were
shopping recreation and work all happen in close proximity. In
part this phenomena is driven by the baby boomers who has a
age factor that make living and entertainment in the close
proximity a necessity of life. The options for boomers are
suburban senior homes or an urban area with all the needed
amenities within reach. Transportation access is also important
for both groups.
So the city Mixed Use (MU) … “zones are designed to provide
facilities for housing, shopping, and business needs, including
residential, office, service, and employment centers.”
B. Program
XYZ Corporation has acquired a 2.4 acre parcel of land on the
Connecticut Ave corridor in North West Washington DC. (See
subdivision record plat Appendix B). In partnership with the
Giant Corp., the company intends to develop a mixed use
building to include retail and office activities on the land in
keeping with the Washington DC Connecticut Ave corridor
urban plan. The project is envisioned to conform to the
implementation of the Comprehensive Plan.
II. PROJECT STATEMENT
With the influx genXers, Milennials, and an establish
population of professional and elderly people[footnoteRef:1]
the XYZ Corporation has determined through market studies
that this site will support a retail and office building. [1:
http://apps.urban.org/features/OurChangingCity/demographics/i
ndex.html#index ]
4. XYZ Corporation recognizes the business advantage of locating
its branch offices in close proximity to several Universities and
on the metro red line. As a result the corporation has assembled
a strategic parcel of land on Connecticut Ave NW adjacent to
the Metro line. (See also Appendix B.)
III. SITE AND ENVIRONMENTAL DATA
A. Climate and Geographical Data
1. Location:Latitude 38° 57' N
Longitude 77° 1' W
2. Elevation at Building Site: 322.0 feet above sea level.
3. Sun Angles:December 21st at Noon 28.55°
June 21st at Noon 75.45°
4. Precipitation:
Normal Annual Rainfall/Moderate (39.73”) (includes 17.3” of
snow)
Snow Fall/Moderate (17.3”)
5. Weather:
Summer-- Days: Hot and Humid
Temperature:Daytime Average: 84.67°F
Nighttime Average: 65.67°F
Wind: Southwest 8.1 – 9.0 MPH
Winter -- Days: Cold and Dry
Temperature:Daytime Average: 43.70°F
Nighttime Range: 28.00°F
5. Wind: Northwest 9.6 – 10.3 MPH
B. Adjacencies and Zoning
The site is located in an MU-7 zone and surrounded by
Institutional use and residential R8 and RA-4 and R-1-B zones.
The zone will provide a broad range of commercial and
institutional activities including office, retail, housing, and
mixed. Consideration shall also be given to DCMR 11 Subtitle
G-17 Article 407 Green Area Ratio (GAR)
The site is bordered on the west by Connecticut Avenue on the
north by Windom Street and on the south by Veazey Terrace.
The east boundary of the site is a major residential complex.
(See Appendix B)
C. Topography
The site is mostly flat but has a difference in elevation
diagonally dropping form east to west. An elevational
difference of approximately eight feet exists between south east
corner and the North West corner of the lot. (See Appendix B)
D. Major View
The major view is to the university campus west and the award
winning Intelsat complex to the south west.
E. Utilities
Underground gas, power, water, sanitary sewer, storm sewer and
communication services are available from Connecticut avenue.
F. Soil and Sub-Surface Conditions
6. 1. Soils are a mixture of very compact sands and gravel with
rock being encountered at depths of 25'-0" to 30'-0".
2. Bearing Capacities:
a. Compact Sands and Gravels 6000 lbs/sq.ft.
b. Granite Bedrock Unlimited
c. Footings:
Bearing wall and/or point loading shall bear on spread footing
on the compact gravel or bedrock.
IV. PROGRAM REQUIREMENTS
A. General Requirements
1. General
a. The program requires the design of a multi-storey building
with the first level dedicate to commercial activities. See the
space program (Appendix E). Two floors shall be configured to
accommodate the corporation’s activities with the remaining
loft spaces to be leased to other businesses interested in
locating in the area.
b. The building design shall be visually compatible with
adjacent and surrounding buildings.
B. Site Requirements
l. General
a. The site is an urban site in uptown Washington, DC. It
consists of approximately 104,718.39 square feet (2.4 acres).
2. Site Circulation
a. Vehicle and Service Access
(1) Parking shall be provided as per DC Zoning Code (DCMR
11 revised) for such sites based on MU-7 zone requirements.
7. (2) Building service and trash collection shall be from the side
streets only.
b. Pedestrian Circulation/Point of Entry
Public access to the building lobby shall be from Connecticut
Ave and located to reflect the location of the metro rail access.
An open plaza will be developed based on the requirements of
MU-10 zone[footnoteRef:2] coordinated with the access of the
office entry lobby. [2: See Mu-10 zone requirements for
plazas]
The corporation has decided that if possible they would like to
utilize the plaza requirements found in MU-10 zones. This they
envision is an enhancement that is complemented by the metro
entrance being on this site in relationship to the multistory
building.
C. Building Requirements
1. General
f. The floor-to-floor heights shall be as follows:
(1) First Floor to Second Floor 15'-0"
(2) Second Floor to Third Floor 10'-0"
(3) Typical Floors 10'-0"
(5) Mechanical & Elevator as required by the program
2. FIRST FLOOR commercial retail43632.66 SF
a. Common Office Building Facilities 2148.00 SF
(1) Entry Vestibule/Building Lobby 800 SF
The main public entry into the office building is an air lock, 8
ft. deep, with two pairs of double doors each at the entry side
8. and the lobby side. After people pass through the entry
vestibule, they enter the office building lobby. Access to some
of the commercial ground floor space can be provided through
this lobby.
(2) Elevators 144.0 SF (net)
Provide four (4) traction-type elevators with a 5 ft. 8 ins. x 4 ft.
8 ins. platforms.
Provide one (1) freight elevator (traction-type) with a 5 ft 4 ins.
x 7 ft 0 ins.
Freight elevator:
https://www.stanleyelevator.com/wp-content/uploads/pdf/A-
Freight-Planning-Guide.pdf
Passenger elevator:
http://sweets.construction.com/swts_content_files/2051/1035_1
42000-oti_08.pdf
(3) Mechanical Equipment Room 300 SF
This room contains the air handling units, electrical switchgear
and panels, water heater(s), and other mechanical equipment for
the first floor. A chase shall be provided in the floors above to
connect the hot and chilled water lines to the boiler and chiller
in the rooftop penthouse. The walls of the mechanical
equipment room shall be of 2-hour fire-resistive construction.
(4) Trash Room/ Receiving Room 350 SF
This is an un-air-conditioned space where trash is collected and
where deliveries are made. Trash will be collected in large
containers which will be rolled out to the street for emptying
into the sanitation trucks. This space shall be on an outside wall
with an exit door and an overhead rolling door approximately 10
ft. wide and 10 ft. tall. The space should be convenient to the
9. elevators, and it should be directly accessible from the non-
public work areas of the office floors and the commercial
floors. Some demarcation shall be provided between the
commercial loading dock and the office floors loading dock.
(5) Miscellaneous Circulation/Stairs 554 SF
b. Leasable floor41484.68 SF
Giant Food Store 9600.00 SF
CVS8000.00 SF
Store(s) of your choice8000.00 SF
Store(s) of your choice7884.68 SF
Store(s) of your choice8000.00SF
3. SECOND through FOURTH FLOOR typical floors130897.98
SF
4. FIFTH and SIXTH FLOOR (Corporate Offices)87265.32 SF
A. Structural System Requirements
Designers are required to show building columns and designate
bearing walls to clearly demonstrate their understanding of the
required structural system. Non-structural floor slabs shall bear
directly on compacted structural fill. Also see soil report at
Section III, F and Code Requirements at Section V.
B. Mechanical Systems Requirements
The mechanical system will be a 4-pipe hot and chilled water
system with a gas fired boiler in the penthouse and an electric,
air-cooled chiller (also in penthouse) employing remote air
handlers in multiple zones. Appropriate chases and horizontal
runs for ductwork must be provided.
V. CODE REQUIREMENTS
10. A. General
The requirements for protecting life, health and public welfare
must be incorporated into your design solution. The site is
located in a hypothetical Fire District and the design shall
conform to codes as indicated below. The International
Building Code shall govern this project.
B. Classifications
The building is classified as business occupancy. The structure
will be non-combustible, protected. An automatic fire
suppression system will be provided throughout.
C. Exiting Requirements
1. Each floor must have a minimum of two exits remotely
located from one another.
2. All doors shall swing in the direction of egress when serving
an occupant load of 50 or more people.
3. The maximum distance of travel from any point to an exterior
exit door, exit passageway, or enclosed exit stair shall not
exceed 200 feet (measured along the line of travel).
4. Dead end pockets or hallways in excess of 20 feet in depth
shall not occur.
5. Every room or suite with an occupant load of more than 50
people shall have at least two egress doorways as remote as
possible from one another.
D. Occupant Load
In determining required exit facilities, the number of occupants
11. for a given space shall be established by the largest number
computed in accordance with the following criteria:
USE
FLOOR AREA (SQ. FT.) PER OCCUPANT
Assembly without fixed seats
7 net
Business Areas
100 gross
E. Stairs
1. Exit stairs shall discharge directly to the exterior of the
building or into an exit passageway leading directly to the
exterior of the building. An exit passageway shall be without
other openings and shall be separated from the remainder of the
building by at least 2-hour fire resistive construction.
Exception: In buildings of business or residential occupancy,
not more than fifty percent (50%) of the required stairways may
discharge through a lobby at grade provided that all spaces at
that level are equipped with an automatic fire suppression
system.
2. An exit stair may discharge into an interior vestibule or
foyer--other than an "exit passageway" or "grade lobby" (See
item E.1. above)--which meets the following criteria:
a. The depth from the exterior of the building is not greater than
ten (10) feet and the length not greater than twenty (20) feet.
b. The foyer is separated from the remainder of the level of
discharge by self-closing doors and at least 2-hour fire resistive
12. construction.
3. The path of exit from a street or grade floor may pass through
an exit stair tower serving the upper floor.
4. Exit stairs wrapping around elevator shafts shall not be
allowed.
5. In buildings of four or more stories, at least one exit stair
shall extend to the roof.
F. Fire Ratings
l. All room and corridor walls, floors and ceilings shall be of at
least one-hour fire-resistive construction.
2. All exit stairs and exit passageways shall have walls, floors
and ceilings of at least two-hour fire-resistive construction.
Exception: In buildings of business or residential occupancy
where a grade lobby is used as an existing element, the lobby
need not be separated from adjacent spaces by a rated partition
provided that all such spaces are equipped with an automatic
fire suppression system.
3. All elevator shafts, mechanical shafts, chases, mechanical
rooms, and trash rooms shall have walls, floors and ceilings of
at least two-hour, fire-resistive construction.
G. Barrier-Free Design
Access to the site and the building shall meet the minimum
requirements of the American National Standards Institute,
Standard A 117.1—latest edition
Note: For further clarification on building code requirements
13. see Building Codes Illustrated: A Guide to Understanding the
2012 International Building Code Jul 10, 2012 by Francis D. K.
Ching and Steven R. Winkel and other resource listed on the
references page (p21)
Blank page
APPENDIX A
Required Drawings
l. Site and First Level Plan (Scale 1/8" = 1'- 0")
a. Indicate building floor plan; label all spaces; show clearly all
walks, site access, service areas, exterior walls, fenestration,
partitions, doors, door swings, stairs, elevators and other major
elements of the design.
b. Show layout of the office lobby, indicating details as directed
by Program Requirements.
c. Indicate Section Cuts.
e. Label all fire wall separations of 2 hours or greater. Color
code red on all drawings.
2. Typical Floor Plan (Scale 1/8" = 1'- 0")
14. a. Indicate building floor plan; label all spaces; show clearly all
service areas, exterior walls, fenestration, partitions, doors,
door swings, stairs, elevators and other major elements of your
design.
b. Indicate Section Cuts.
c. Label all fire wall separations of 2 hours or greater. Color
code red on all drawings.
3. North, and South, East, and West Elevation (Scale 1/8" = 1'-
0")
Show all fenestration and response to sun exposure.
5. Building Sections (Scale 1/8" = 1'- 0")
Draw a complete longitudinal and cross section through your
building. The sections must indicate a clear understanding of
materials, assemblies, and building systems. Show the
following:
a. Structural System Elements
b. Mechanical System Elements
c. Critical Vertical Dimensions (foundation, floor to floor, floor
to ceiling, etc.)
d. Label all fire wall separations of 2 hours or greater. Color
code red on all drawings.
6. Wall Section (Scale 1 ½” = 1’- 0”)
Draw a wall section at the scale indicated to show the exterior
wall relationship to the floors, roof and foundation and footing
system.
In a separate schedule place in your project binder additional
15. brief notes should be used to further describe and clarify your
building design solution. Indicate the location of section cuts
on all floor plans.
Grading Criteria
Solution
s will be graded in the following areas. A solution must be at
least minimally acceptable in each major category.
1. Program Requirements
a. Development of All Programmed Spaces.
b. Conformance to Square Footage/Proportions.
c. Compliance with Required Spatial Relationships.
2. Design
a. Circulation.
b. Spatial Relationships/Proportions/Adjacencies.
c. Relationship to Existing Context.
3. Code Compliance
16. a. Fire Separations.
b. Accessibility.
c. Means of Egress.
d. Zoning requirements
4. Technical Aspects
a. Materials Selection.
b. Structural Systems.
c. Mechanical Systems.
5. Completeness & Clarity of Presentation, Adherence to
program Instructions, or Required drawing(s). Missing drawing
elements will reduce score by 5 points.
NOTE: