    POINT-TO-POINT (PTP)
    LIGHTNING PROTECTION UNIT
    LIGHTNING PROTECTION FOR PTP 250, 300, 500 AND 600 RADIOS




Cambium Point-to-Point (PTP) 250, 300, 500 and 600 Series Solutions include
robust radios designed to withstand the toughest conditions. Because
they are often perched on high towers, sometimes with antennas, they are
located in situations that can attract lightning. The Cambium PTP Lightning
Protection Unit (PTP-LPU) is a device that shields your PTP radios from the
harmful effects of sudden surges in power induced by electro-magnetic
activity (lightning). While you can purchase a Cambium All Risks Extended
Warranty that covers lightning strikes, the warranty only covers the cost of
replacing the radio. It is a good idea to start out with lightning protection at
initial deployment to avoid the delays and costs associated with taking down
damaged devices and installing replacement units.
RUGGEDIZED DESIGN                                                 your radios the best possible protection from the harmful      KEY FEATURES
The PTP Lightning Protection Unit offers two protection           effects of lightning. However, 100% protection is neither      •	 ypical response time –
                                                                                                                                   T
                                                                                                                                   5 nanoseconds
methods – line-to-line and line-to-ground – to ensure that        implied nor possible.                                          •	 ine-to-line and line-to-ground
                                                                                                                                   L
a surge in power is stopped in its tracks. When installed                                                                          protection
correctly, using solid shielded CAT5e cable, the PTP-LPU          PTP-LPU units have a projected operational life of 10 years.   •	 obust metal enclosure
                                                                                                                                   R
                                                                                                                                 •	 onnects via RJ-45 screened
                                                                                                                                   C
will ground the surge almost instantaneously (typically           The device’s metal enclosure provides a tough body armor         connector
within five nanoseconds). By grounding the power surges           that protects your units against battering from winds up to    •	 perates in -40° to +140° F
                                                                                                                                   O
before they can harm the units, the Cambium PTP-LPU gives         150 mph (242 kph), rain, ice and snow.                           (-40° to +60°) temperatures
                                                                                                                                 •	 ithstands up to 150 mph
                                                                                                                                   W
                                                                                                                                   (242 kph) winds




PTP-LPU DATA SHEET
EASY MOUNTING, EASY INSTALLATION                                                        Unit (PTP-LPU) is required near the base of the tower or wall
Easily mounted on a wall or tower with a PTP radio, the                                 at the cable-entrance point leading to the network. That unit
PTP-LPU includes a minimum of components. Although each                                 protects the LAN network inside the building.
unit is housed in a metal enclosure, the PTP-LPU is small
and lightweight, making it extremely easy to transport even                             LIGHTWEIGHT PRICE FOR FAST ROI
up the highest towers. The connections are designed for                                 Best of all, the units are very cost effective, making your
simplicity, requiring no special knowledge or expertise.                                lightning-protection investment well worth it. Along with
                                                                                        the mounting hardware, the PTP-LPU End Kit for PTP 600
Each PTP 600 radio requires two PTP-LPU devices – one                                   systems includes two units, plus the necessary cables
installed on the tower or mast adjacent to the radio and one                            (excluding the drop cable and connection to your network                              PTP-LPU
installed at the cable entrance point leading to the network.                           equipment) and glands in a single kit. For PTP 250, 300 and
Each PTP 250, 300 or 500 radio requires only one PTP-LPU,                               500 systems, the PTP-LPU End Kit includes one unit, plus the
because these radios have built-in lightning protection                                 necessary cables and glands. In all cases, you will need two
capability. So, only one external PTP Lightning Protection                              kits for each PTP link.

   Feature                                                                              Description
   Transfer rate                                                                        1000 Base T
   Connectors                                                                           RJ 45
   Protection mode                                                                      Line-to-line and line-to-ground
   Response time                                                                        5 nanoseconds typical
   Mounting                                                                             Pole mount 1-3” (25-75 mm) or wall mount
   Metal enclosure                                                                      Projected 10-year operational life
   Dimensions (including glands)                                                        6.3” Length (16 cm), 4” (10 cm) Width, 3.5” (9 cm) Height
   Weight                                                                               1.5 lbs (700 g)
   Wind loading                                                                         150 mph (242 kph)
   Operating temperature                                                                -40° F (-40° C) to +140° F (+60° C)
   Humidity                                                                             100% condensing
   Tested to IEEE / ANSI C62.41 10/1000 long wave                                       120 amp peak, peak power 14,000 watts
   Environmental protection                                                             IP66 / NEMA-3R


For more information, refer to our PTP Solutions.




                                                           TM
                                                                                                                                 www.cambiumnetworks.com


Cambium Networks and the stylized circular logo are trademarks of Cambium Networks, Ltd. All other trademarks are the property of their respective owners. © Copyright 2012
Cambium Networks, Ltd. All rights reserved.
PTP-LPU DS 050312

More Related Content

What's hot

Cambium networks ptp_200_(4.9_g_hz)_specification
Cambium networks ptp_200_(4.9_g_hz)_specificationCambium networks ptp_200_(4.9_g_hz)_specification
Cambium networks ptp_200_(4.9_g_hz)_specification
Advantec Distribution
 
Como pasar de redes HFC a tecnología RFoG
Como pasar de redes HFC a tecnología RFoGComo pasar de redes HFC a tecnología RFoG
Como pasar de redes HFC a tecnología RFoG
Cable Servicios S.A.
 
Data sheet en_us_1933714827
Data sheet en_us_1933714827Data sheet en_us_1933714827
Data sheet en_us_1933714827
amthanhbosch
 
Tranzeo TR – SL9 Series (quantumwimax.com)
Tranzeo TR – SL9 Series (quantumwimax.com)Tranzeo TR – SL9 Series (quantumwimax.com)
Tranzeo TR – SL9 Series (quantumwimax.com)
Ari Zoldan
 
Cambium networks ptp_230_specification
Cambium networks ptp_230_specificationCambium networks ptp_230_specification
Cambium networks ptp_230_specification
Advantec Distribution
 

What's hot (15)

Trth1000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7
Trth1000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7Trth1000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7
Trth1000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7
 
Trth2000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7
Trth2000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7Trth2000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7
Trth2000 24 ofdm-tdma long distance wireless backhaul datasheet-v1.0.7
 
Ptp overview
Ptp overviewPtp overview
Ptp overview
 
Cambium networks ptp_200_(4.9_g_hz)_specification
Cambium networks ptp_200_(4.9_g_hz)_specificationCambium networks ptp_200_(4.9_g_hz)_specification
Cambium networks ptp_200_(4.9_g_hz)_specification
 
Como pasar de redes HFC a tecnología RFoG
Como pasar de redes HFC a tecnología RFoGComo pasar de redes HFC a tecnología RFoG
Como pasar de redes HFC a tecnología RFoG
 
Data sheet en_us_1933714827
Data sheet en_us_1933714827Data sheet en_us_1933714827
Data sheet en_us_1933714827
 
Hfc f outside plan
Hfc f outside planHfc f outside plan
Hfc f outside plan
 
Tranzeo TR – SL9 Series (quantumwimax.com)
Tranzeo TR – SL9 Series (quantumwimax.com)Tranzeo TR – SL9 Series (quantumwimax.com)
Tranzeo TR – SL9 Series (quantumwimax.com)
 
Cambium networks ptp_230_specification
Cambium networks ptp_230_specificationCambium networks ptp_230_specification
Cambium networks ptp_230_specification
 
Rg58 vs lmr400
Rg58 vs lmr400Rg58 vs lmr400
Rg58 vs lmr400
 
Cn ptp durability_fs_012012_final
Cn ptp durability_fs_012012_finalCn ptp durability_fs_012012_final
Cn ptp durability_fs_012012_final
 
5 Installing Premises Cabling System
5 Installing Premises Cabling System5 Installing Premises Cabling System
5 Installing Premises Cabling System
 
Hfc i fiber management
Hfc i fiber managementHfc i fiber management
Hfc i fiber management
 
3 Basic Principal Of Fo Installation
3 Basic Principal Of Fo Installation3 Basic Principal Of Fo Installation
3 Basic Principal Of Fo Installation
 
2 Basic Principal Of Utp Installation
2 Basic Principal Of Utp Installation2 Basic Principal Of Utp Installation
2 Basic Principal Of Utp Installation
 

Viewers also liked (20)

Congress[1]
Congress[1]Congress[1]
Congress[1]
 
Centre sustainability one pager v01
Centre sustainability one pager v01Centre sustainability one pager v01
Centre sustainability one pager v01
 
Pacie en accion fase-planificacion
Pacie en accion fase-planificacionPacie en accion fase-planificacion
Pacie en accion fase-planificacion
 
交點台中Vol.16 - 開場簡報
交點台中Vol.16 - 開場簡報交點台中Vol.16 - 開場簡報
交點台中Vol.16 - 開場簡報
 
Pdf ....
Pdf ....Pdf ....
Pdf ....
 
Syz & co syz asset management - 1 year in 10 snapshots 2013
Syz & co   syz asset management - 1 year in 10 snapshots 2013Syz & co   syz asset management - 1 year in 10 snapshots 2013
Syz & co syz asset management - 1 year in 10 snapshots 2013
 
Info y doc 2
Info y doc  2Info y doc  2
Info y doc 2
 
111
111111
111
 
Componentes para armar pc
Componentes para armar pcComponentes para armar pc
Componentes para armar pc
 
Understanding marketing problem from a communication perspective
Understanding marketing problem from a communication perspectiveUnderstanding marketing problem from a communication perspective
Understanding marketing problem from a communication perspective
 
Erinys
ErinysErinys
Erinys
 
11번가 프리
11번가 프리11번가 프리
11번가 프리
 
Las redes sociales en internet
Las redes sociales en internetLas redes sociales en internet
Las redes sociales en internet
 
Lakshmi
LakshmiLakshmi
Lakshmi
 
Presentacion P P
Presentacion P PPresentacion P P
Presentacion P P
 
Développement territorial de la communauté d’agglomération cœur d’ardenne
Développement territorial de la communauté d’agglomération cœur d’ardenneDéveloppement territorial de la communauté d’agglomération cœur d’ardenne
Développement territorial de la communauté d’agglomération cœur d’ardenne
 
Bulletin d'inscription 2013
Bulletin d'inscription 2013Bulletin d'inscription 2013
Bulletin d'inscription 2013
 
Nivell c català
Nivell c catalàNivell c català
Nivell c català
 
2circuitelec
2circuitelec2circuitelec
2circuitelec
 
Walking in the clouds
Walking in the cloudsWalking in the clouds
Walking in the clouds
 

Similar to Ptp lpu ds-050312

Tranzeo TR – 902 Series (quantumwimax.com)
Tranzeo TR – 902 Series (quantumwimax.com)Tranzeo TR – 902 Series (quantumwimax.com)
Tranzeo TR – 902 Series (quantumwimax.com)
Ari Zoldan
 
Tranzeo TR – SL5 Series (quantumwimax.com)
Tranzeo TR – SL5 Series (quantumwimax.com)Tranzeo TR – SL5 Series (quantumwimax.com)
Tranzeo TR – SL5 Series (quantumwimax.com)
Ari Zoldan
 
Tranzeo TR – 500 Series (quantumwimax.com)
Tranzeo TR – 500 Series (quantumwimax.com)Tranzeo TR – 500 Series (quantumwimax.com)
Tranzeo TR – 500 Series (quantumwimax.com)
Ari Zoldan
 
Tranzeo TR – 49 Series (quantumwimax.com)
Tranzeo TR – 49 Series (quantumwimax.com)Tranzeo TR – 49 Series (quantumwimax.com)
Tranzeo TR – 49 Series (quantumwimax.com)
Ari Zoldan
 
Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)
Ari Zoldan
 
Cambium networks ptp_500_specification
Cambium networks ptp_500_specificationCambium networks ptp_500_specification
Cambium networks ptp_500_specification
Advantec Distribution
 
Tranzeo TR-5amp Series (quantumwimax.com)
Tranzeo TR-5amp Series (quantumwimax.com)Tranzeo TR-5amp Series (quantumwimax.com)
Tranzeo TR-5amp Series (quantumwimax.com)
Ari Zoldan
 

Similar to Ptp lpu ds-050312 (20)

Ptp sync ss-040412
Ptp sync ss-040412Ptp sync ss-040412
Ptp sync ss-040412
 
Cn ptp durability_fs_012012_final
Cn ptp durability_fs_012012_finalCn ptp durability_fs_012012_final
Cn ptp durability_fs_012012_final
 
Ptp durability fs_012012
Ptp durability fs_012012Ptp durability fs_012012
Ptp durability fs_012012
 
Ptp durability fs_012012
Ptp durability fs_012012Ptp durability fs_012012
Ptp durability fs_012012
 
Flexible Cables Solution
Flexible Cables SolutionFlexible Cables Solution
Flexible Cables Solution
 
Tranzeo TR – 902 Series (quantumwimax.com)
Tranzeo TR – 902 Series (quantumwimax.com)Tranzeo TR – 902 Series (quantumwimax.com)
Tranzeo TR – 902 Series (quantumwimax.com)
 
Tr5 Plus
Tr5 PlusTr5 Plus
Tr5 Plus
 
Tranzeo TR – SL5 Series (quantumwimax.com)
Tranzeo TR – SL5 Series (quantumwimax.com)Tranzeo TR – SL5 Series (quantumwimax.com)
Tranzeo TR – SL5 Series (quantumwimax.com)
 
Ptp800 05 br-022012
Ptp800 05 br-022012Ptp800 05 br-022012
Ptp800 05 br-022012
 
Tranzeo TR – 500 Series (quantumwimax.com)
Tranzeo TR – 500 Series (quantumwimax.com)Tranzeo TR – 500 Series (quantumwimax.com)
Tranzeo TR – 500 Series (quantumwimax.com)
 
SebKMT Cable Sheath testers & Fault Locators
SebKMT Cable Sheath testers & Fault LocatorsSebKMT Cable Sheath testers & Fault Locators
SebKMT Cable Sheath testers & Fault Locators
 
Tranzeo TR – 49 Series (quantumwimax.com)
Tranzeo TR – 49 Series (quantumwimax.com)Tranzeo TR – 49 Series (quantumwimax.com)
Tranzeo TR – 49 Series (quantumwimax.com)
 
Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)Tranzeo TR – 5plus Series (quantumwimax.com)
Tranzeo TR – 5plus Series (quantumwimax.com)
 
Cambium networks ptp_500_specification
Cambium networks ptp_500_specificationCambium networks ptp_500_specification
Cambium networks ptp_500_specification
 
Tranzeo TR-5amp Series (quantumwimax.com)
Tranzeo TR-5amp Series (quantumwimax.com)Tranzeo TR-5amp Series (quantumwimax.com)
Tranzeo TR-5amp Series (quantumwimax.com)
 
Quad Small Form-factor Pluggable (QSFP) Interconnect System
Quad Small Form-factor Pluggable (QSFP) Interconnect SystemQuad Small Form-factor Pluggable (QSFP) Interconnect System
Quad Small Form-factor Pluggable (QSFP) Interconnect System
 
Commscope-Andrew PX2F-52-NXA
Commscope-Andrew PX2F-52-NXACommscope-Andrew PX2F-52-NXA
Commscope-Andrew PX2F-52-NXA
 
LayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: eRPP Remote Power PanelLayerZero Series 70: eRPP Remote Power Panel
LayerZero Series 70: eRPP Remote Power Panel
 
Ptp810 01 ds-050812-r10
Ptp810 01 ds-050812-r10Ptp810 01 ds-050812-r10
Ptp810 01 ds-050812-r10
 
Synchronization protection & redundancy in ng networks itsf 2015
Synchronization protection & redundancy in ng networks   itsf 2015Synchronization protection & redundancy in ng networks   itsf 2015
Synchronization protection & redundancy in ng networks itsf 2015
 

More from Advantec Distribution (20)

E pmp for public presentation feb 27 2015
E pmp for public presentation feb 27 2015E pmp for public presentation feb 27 2015
E pmp for public presentation feb 27 2015
 
1 wi ng5_wlan_brochure
1 wi ng5_wlan_brochure1 wi ng5_wlan_brochure
1 wi ng5_wlan_brochure
 
Vx9000 datasheet
Vx9000 datasheetVx9000 datasheet
Vx9000 datasheet
 
Nx7500 datasheet
Nx7500 datasheetNx7500 datasheet
Nx7500 datasheet
 
Nx9500 datasheet
Nx9500 datasheetNx9500 datasheet
Nx9500 datasheet
 
Nx4500 6500 datasheet
Nx4500 6500 datasheetNx4500 6500 datasheet
Nx4500 6500 datasheet
 
Rfs7000 datasheet
Rfs7000 datasheetRfs7000 datasheet
Rfs7000 datasheet
 
Rfs6000 datasheet
Rfs6000 datasheetRfs6000 datasheet
Rfs6000 datasheet
 
Rfs4000 datasheet
Rfs4000 datasheetRfs4000 datasheet
Rfs4000 datasheet
 
Ap8200 datasheet
Ap8200 datasheetAp8200 datasheet
Ap8200 datasheet
 
Ap7181 datasheet
Ap7181 datasheetAp7181 datasheet
Ap7181 datasheet
 
Ap8222 datasheet
Ap8222 datasheetAp8222 datasheet
Ap8222 datasheet
 
Ap8163 datasheet
Ap8163 datasheetAp8163 datasheet
Ap8163 datasheet
 
Ap6562 datasheet
Ap6562 datasheetAp6562 datasheet
Ap6562 datasheet
 
Ap8122 datasheet
Ap8122 datasheetAp8122 datasheet
Ap8122 datasheet
 
Ap8132 datasheet
Ap8132 datasheetAp8132 datasheet
Ap8132 datasheet
 
Ap7532 datasheet
Ap7532 datasheetAp7532 datasheet
Ap7532 datasheet
 
Ap7502 datasheet
Ap7502 datasheetAp7502 datasheet
Ap7502 datasheet
 
Ap7131 datasheet
Ap7131 datasheetAp7131 datasheet
Ap7131 datasheet
 
Ap7522 datasheet
Ap7522 datasheetAp7522 datasheet
Ap7522 datasheet
 

Ptp lpu ds-050312

  • 1. TM POINT-TO-POINT (PTP) LIGHTNING PROTECTION UNIT LIGHTNING PROTECTION FOR PTP 250, 300, 500 AND 600 RADIOS Cambium Point-to-Point (PTP) 250, 300, 500 and 600 Series Solutions include robust radios designed to withstand the toughest conditions. Because they are often perched on high towers, sometimes with antennas, they are located in situations that can attract lightning. The Cambium PTP Lightning Protection Unit (PTP-LPU) is a device that shields your PTP radios from the harmful effects of sudden surges in power induced by electro-magnetic activity (lightning). While you can purchase a Cambium All Risks Extended Warranty that covers lightning strikes, the warranty only covers the cost of replacing the radio. It is a good idea to start out with lightning protection at initial deployment to avoid the delays and costs associated with taking down damaged devices and installing replacement units. RUGGEDIZED DESIGN your radios the best possible protection from the harmful KEY FEATURES The PTP Lightning Protection Unit offers two protection effects of lightning. However, 100% protection is neither • ypical response time – T 5 nanoseconds methods – line-to-line and line-to-ground – to ensure that implied nor possible. • ine-to-line and line-to-ground L a surge in power is stopped in its tracks. When installed protection correctly, using solid shielded CAT5e cable, the PTP-LPU PTP-LPU units have a projected operational life of 10 years. • obust metal enclosure R • onnects via RJ-45 screened C will ground the surge almost instantaneously (typically The device’s metal enclosure provides a tough body armor connector within five nanoseconds). By grounding the power surges that protects your units against battering from winds up to • perates in -40° to +140° F O before they can harm the units, the Cambium PTP-LPU gives 150 mph (242 kph), rain, ice and snow. (-40° to +60°) temperatures • ithstands up to 150 mph W (242 kph) winds PTP-LPU DATA SHEET
  • 2. EASY MOUNTING, EASY INSTALLATION Unit (PTP-LPU) is required near the base of the tower or wall Easily mounted on a wall or tower with a PTP radio, the at the cable-entrance point leading to the network. That unit PTP-LPU includes a minimum of components. Although each protects the LAN network inside the building. unit is housed in a metal enclosure, the PTP-LPU is small and lightweight, making it extremely easy to transport even LIGHTWEIGHT PRICE FOR FAST ROI up the highest towers. The connections are designed for Best of all, the units are very cost effective, making your simplicity, requiring no special knowledge or expertise. lightning-protection investment well worth it. Along with the mounting hardware, the PTP-LPU End Kit for PTP 600 Each PTP 600 radio requires two PTP-LPU devices – one systems includes two units, plus the necessary cables installed on the tower or mast adjacent to the radio and one (excluding the drop cable and connection to your network PTP-LPU installed at the cable entrance point leading to the network. equipment) and glands in a single kit. For PTP 250, 300 and Each PTP 250, 300 or 500 radio requires only one PTP-LPU, 500 systems, the PTP-LPU End Kit includes one unit, plus the because these radios have built-in lightning protection necessary cables and glands. In all cases, you will need two capability. So, only one external PTP Lightning Protection kits for each PTP link. Feature Description Transfer rate 1000 Base T Connectors RJ 45 Protection mode Line-to-line and line-to-ground Response time 5 nanoseconds typical Mounting Pole mount 1-3” (25-75 mm) or wall mount Metal enclosure Projected 10-year operational life Dimensions (including glands) 6.3” Length (16 cm), 4” (10 cm) Width, 3.5” (9 cm) Height Weight 1.5 lbs (700 g) Wind loading 150 mph (242 kph) Operating temperature -40° F (-40° C) to +140° F (+60° C) Humidity 100% condensing Tested to IEEE / ANSI C62.41 10/1000 long wave 120 amp peak, peak power 14,000 watts Environmental protection IP66 / NEMA-3R For more information, refer to our PTP Solutions. TM www.cambiumnetworks.com Cambium Networks and the stylized circular logo are trademarks of Cambium Networks, Ltd. All other trademarks are the property of their respective owners. © Copyright 2012 Cambium Networks, Ltd. All rights reserved. PTP-LPU DS 050312