2. ??
Global causes of Blindness in 2010
RE: Refractive Errors
AMD: Age related Macular Degeneration
CO : Corneal Opacities
DR: Diabetic Retinopathy
Source : http://www.who.int/blindness/estimates2011.pdf
4. • ERG and VEP are both electrophysiology tests and can be compared to ECG.
• ERG (ElectroRetinoGraphy) is an eye test that evaluates the function of the retinal
cells of the eye.
The ERG test helps diagnose retinal diseases and also diseases in the body that
secondary affect the eye (diseases like diabetic retinopathy).
• VEP (Visual Evoked Potentials) are used to detect and evaluate dysfunction of the
optic pathway including the visual cortex, like inflammation of the optic nerve or
diseases like Multiple Sclerosis.
5.
6. Unique Positioning
∗ ephiós ERG and VEP is handheld. Use anywhere at anytime enhancing the
access to this diagnostic modality to the masses as a screener.
∗ Comprehensive Vision Examination with a high degree of sensitivity and
specificity for detection of ROP.
∗ 5-10 times cheaper than the existing stationary ERG & VEP system
∗ Conforms to the ISCEV Standard Protocol
∗ Safe for patients. Runs on a battery.
∗ Is “tele-diagnosis” enabled for remote specialist reading. ERG and VEP data
gives higher sensitivity in telediagnosis – Compact data transmission than
fundus image and much lower intra/inter-operator variability.
7. Key Customer Feedback
The easy portability and performance of the product has enabled me to conduct a VEP
& ERG examination in the Operating Room – Dr. Parveen Sen, Sankara Neteralaya,
Chennai, India
I have been able to use the ephios Handheld ERG & VEP in the most rural parts of
Gujarat and diagnose pediatric patients in the pre speech age- The device is operated
by a technician in a remotely located health camp and recorded data relayed to me by
e-mail for reading and interpretation. Has been working very well for my kind of work
Dr. Jitendra Jethani, Dr. T.V. Patel Eye Institute, Vadodara, India
The ephios handheld ERG was subjected to a performance comparison with the
standard ERG equipment we have been using and compared very well. Its handheld
format and price will definitely go a long way in making this sophisticated diagnostic
procedure more accessible and affordable to the people – Dr. Vikas Kaitan, Sankara
Netralaya, Chennai, India
8. Epidemiology of Vision Related Diseases
Indication Prevalence Prevalence in Current ERG/VEP
in India Sub ROW(/1000) Diagnostic role as
Continent Screening Diagnostic
(/1000) /Screener
Retinitis Pigmentosa 1 0.25 Not Yes
Available
Diabetic Mellitus & Retinopathy 0.63 (2006) 24.2 (2011) NA Yes
Macula Degeneration 90 - NA Yes
Retinopathy of Prematurity (ROP) 2 0.95 NA Yes
India: 22.5 birth/1000/year
ROW: 19.95 birth/1000/year
Toxicity Alcohol Induced 206 No Available NA Yes
India: 16.7%- 58% of population
(50%- Illicit Liquor) Data
Childhood Blindness 0.80 0.30 NA Yes
Glaucoma 58.3 - NA Yes
9. Epidemiology of Vision Related Diseases
Indication Prevalence Prevalence in Current ERG/VEP
in India Sub ROW(/1000) Diagnostic role as
Continent Screening Diagnostic /
(/1000) Screener
fetal alcohol syndrome (FAS) No Available 0.2 – 1.5 Not Yes
alcohol-related neurodevelopmental
disorder (ARND) per 1000 life birth Data (NAD) Available
(NA)
Optic neuropathy NAD 1.15 NA Yes
Albinism NAD 0.50 NA Yes
Progressive Cone Dystropies NAD 0.30 NA Yes
Achromatopsia NAD NA Yes
Metallic Intraocular Foreign bodies NAD NA Yes
Disassociative Visual Disorder NAD NA Yes
10. ERG/VEP Tests are indicated
∗ In cases where ophthalmoscopic observation is
precluded due to the presence of opacities in the
media.
∗ When subjective tests are unreliable due to the age of
the patient.
∗ In prognosis in cases of vascular disorders.
∗ In early diagnosis of hereditary or congenital diseases.
∗ In prevention of disease, as in toxic retinopathies.
∗ In providing information in some of the conditions
where there are no physical signs of eye disease.
11. Need for handheld ERG/VEP System
∗ To reach to the population & help early detection of retinal diseases,
optical nerve disorders & retinopathy from ocular diseases.
∗ High cost of tests & limited health infrastructure which is concentrated in
urban population.
∗ >70% of most effected population lives in rural/semi urban areas, can’t be
reached with expensive stationary ERG & VEP systems.
∗ Prelim screening of rural population.
“The etiology and pathology of blindness has always been reported with a very
significant number of cases that are reported as of unknown origin. Handheld Visual
Electrophysiology equipments can help finding some answers.”
12. Co operation
∗ Björn-Åke Skjöld Master of degree of fine arts, Stockholm. Skjöld Design AB,
Design is an International Red Dot Design Award winning design
company. Working in Medical Devices, Traffic safety for
children, ergonomics for last 25+ years.
Designed ephiós handheld ERG/VEP Unit.
∗ Linköping University ephiós is working with Department of Biomedical Engineering
in the area of electronics design, programming, imaging,
wireless & optical methods on new modalities.
And Regulations for Medical Devices and hospitals, CE.
∗ NTH New tools for Health, organization with contacts for verify
Member and test of new methods and products.
∗ Clinical Research ephiós is in discussion for partnership with leading clinical
research organization for data collection & its management.
13. “Thank you for you Patience”
Contact:
Aditya Prakash
ephios Medicare (P) Limited, New Delhi, India
ephiós ab, Norrköping, Sweden
Website www.ephios.com | e-mail: aditya.prakash@ephios.com; aditya@srsglobalsoft.com
Address Visit C/o Swedish Trade Council - Exportradet, Embassy of Sweden, Nyaya Marg, Chanakayapuri, New
Delhi- 110 021
Mobile India +91 98110 61885 | fax +91 11 46 06 7110