SlideShare a Scribd company logo
1 of 44
Download to read offline
1
Welcome to the Pureit Family
REACH PUREIT AT
www.pureitwater.com
1860-210-1000
Removes 1 Crore virus in 1 Litre of water *
1
Congratulations!
Welcome to the Pureit Family! We thank you for the trust you
have shown in our product and we guarantee you that our
product will live up to your expectations. Pureit is trusted by
millions of users around the world for providing safe drinking
water for their loved ones.
Our product is developed by experts and is designed to give
you water that is ‘Safer Than Boiled Water’. Pureit adheres to
some of the toughest standards of leading institutions both in
India and abroad.
If ever you need to get in touch with us for anything, please call
us at 1860-210-1000.
We once again thank you for buying our product and we look
forward to a long and fruitful association with you.
~YmB©!
߶mo[aQ> n[adma ‘| AmnH$m ñdmJV h¡! AmnZo h‘mao CËnmX ‘| Omo é{M
{XImB© h¡ CgHo$ {bE YݶdmX Am¡a h‘ Jma§Q>r XoVo h¢ {H$ h‘mao
CËnmX AmnH$s AnojmAm| na Iam CVa|Jo& AnZo {à¶OZm| H$mo gwa{jV nrZo
H$m nmZr CnbãY H$amZo Ho$ {bE Xþ{Z¶m ^a ‘| bmIm| Cn^moº$mAm| Zo ߶mo[aQ>
na {dídmg {H$¶m h¡&
h‘mao CËnmX H$mo E³gnQ>©g Zo {dH${gV {H$¶m h¡ Am¡a Bg Vah
{S>OmBZ {H$¶m h¡ {Oggo dh AmnH$mo ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’
Xo gHo$ & ߶mo[aQ> ^maV d {dXoe H$s à‘wI B§ñQ>rQ²>¶ye§g Ho$ H${R>Z ñQ>¢S>S>©g
H$m nmbZ H$aVm h¡&
{H$gr H$maU go ¶{X AmnH$mo h‘go g§nH©$ H$aZo H$s Amdí¶H$Vm hmo,
Vmo H¥$n¶m h‘| 1860-210-1000 na ’$moZ H$a|&
AmnZo h‘mam CËnmX IarXm CgHo$ {bE nwZ… YݶdmX Ed§ h‘ Amngo b§~m d
‘Ywa gå~ÝY ~ZmE aIZo H$s Amem aIVo h¢&
Removes 1 Crore virus in 1 Litre of water*
World’s largest selling purifier#
3
Pureit advantages
߶mo[aQ> ES>dmÝgS> Ho$ ’$m¶Xo ......................................................................... 4
Getting to Know Your Pureit
AnZo ߶mo[aQ> ES>dmÝgS H$mo Om{ZE.................................................................. 6
How Pureit Works
߶mo[aQ> ES>dmÝgS> H¡$go H$m‘ H$aVm h¡............................................................... 8
Setting up Pureit
߶mo[aQ> ES>dmÝgS H$s ñWmnZm....................................................................... 9
Ordering the Germkill Kit™
O‘©{H$b {H$Q™ IarXZm........................................................................... 13
Cleaning & maintenance of Pureit
߶mo[aQ> ES>dmÝgS H$s g’$mB© Am¡a aI aImd.................................................... 16
Do’s & Don’ts
³¶m H$a| Am¡a ³¶m Zm H$a|.......................................................................... 28
FAQs
A³ga nyN>o OmZo dmbo gdmb...................................................................... 32
Pureit Advanced Warranty Details
߶mo[aQ> ES>dmÝgS dmaÝQ>r {ddaU.................................................................. 36
Technical specifications for Pureit Advanced
߶mo[aQ> ES>dmÝgS H$s VH$ZrH$s OmZH$mar........................................................ 39
CONTENTS
gyMr
4
pureit Advanced Advantages
߶mo[aQ> ES>dmÝgS> Ho$ ’$m¶Xo
Auto Shut-Off™
Am°Q>mo eQ>-Am°µ’$™
Safer Than Boiled Water~
C~bo nmZr go µÁ¶mXm gwa{jV nmZr~
No harmful bacteria, virus & parasites
H$moB© hm{ZH$maH$ ~¡³Q>o[a¶m, dmBag ¶m
n¡amgmB©Q> Zht
No boiling
nmZr C~mbZo H$s µOéaV Zht
No gas
J¡g H$s µOéaV Zht
No electricity
{~Obr H$s µOéaV Zht
No continuous tap water needed
~hVo nmZr H$s µOéaV Zht
Easy maintenance
AmgmZ aI aImd
With double protection
XþJZr gwajm Ho$ gmW
New generation Microcharged
Membrane technology
ZB© nr‹T>r H$s ‘mBH«$moMmÁS>© ‘oå~«oZ VH$ZrH$
5
pureit Advanced Advantages
߶mo[aQ> ES>dmÝgS> Ho$ ’$m¶Xo
Strong and durable
‘µO~yV Am¡a {Q>H$mD$
Food grade plastic
ImÚ J«oS> ßbmpñQ>H$
No chlorine taste
³bmoarZ ñdmX Zht h¡
No A.M.C
Eo.E‘.gr H$s µOéaV Zht
No undesirable odour
H$moB© XþJ©ÝY Zht
No plumbing
ßb§q~J H$s µOéaV Zht
Natural tasting water
àmH¥${VH$ ñdmX
Great after sales service
{~H«$s Ho$ ~mX AÀN>r godm
World’s largest selling water purifier
Xþ{Z¶m H$m g~go Á¶mXm {~H$Zo dmbm
dmQ>a ߶moar’$m¶a
6
GETTINGTO KNOWYOUR pureit Advanced
AnZo ߶mo[aQ> ES>dmÝgS> H$mo Om{ZE
Top Lid
Q°mn {bS
Top Cover
Q°mn H$da
Top Chamber
Q°mn M¡å~a
Carbon Polisher™
H$m~©Z nm{bea™
Advanced Microfiber Mesh™
ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™
7
Germkill Life Indicator™ Cover
O‘©{H$b bmB’$ B§{SHo$Qa™ H$da
Tap
Zb
Microcharged Membrane assembly
‘mBH«$moMmµÁS© ‘oå~«Z Agoåãbr
Transparent Chamber
Q´§mgna|Q M¡å~a
Pedestal
noSoñQb
Germkill Life Indicator™ O‘©{H$b bmB’$ B§{SHo$Qa™
Cleansing Collection Chamber ³b|qOJ H$bo³eZ M¡å~a
Germkill Processor™ O‘©{H$b àmogoga™
Batching Chamber
~¡qMJ M¡å~a
GETTINGTO KNOWYOUR pureit Advanced
AnZo ߶mo[aQ ESdmÝgS H$mo Om{ZE
8
How Pureit Advanced Works
nmo[aQ ESdmÝgS H¡$go H$m‘ H$aVm h¡
Removes
harmful parasites,
pesticides and
chlorine, making the
water clear, odorless
and natural
tasting.
Carbon Polisher™
Purifies
the water again
and removes
harmful parasites
giving the assurance
of double
protection.
Mic
rocharged Membr
ane
hm{ZH$maH$ naOrdr,
H$sQZmeH$ VWm ³bmoarZ
H$mo {ZH$mbVm h¡ Am¡a nmZr
H$mo ñdÀN, J§YhrZ ~Zm Ho$
àmH¥${VH$ ñdmX XoVm h¡ 
H$m~©Z nm{bea™
nmZr H$mo {’$a go ewÕ
H$aVm h¡ Am¡a hm{ZH$maH$
naOrdr H$mo hQmVm h¡ VWm
XþJwZr gwajm H$m AmœmgZ
XoVm h¡ 
‘mBH«$moMmÁS© ‘oå~«oZ
Uses
‘Programmed
Germkill Technology’
to target and remove
harmful viruses and
bacteria.
hm{ZH$maH$
dm¶ag Am¡a ~o³Qo[a¶m H$mo
bú¶ ~ZmH$a Xÿa H$aZo Ho$
{bE “àm¡Úmo{JH$
H$sQmUy ZmeH$ VH$ZrH$”
H$m à¶moJ H$aVm h¡ 
O‘©{H$b àmogoga™
Removes
visible dirt and
precipitated
metallic
impurities.
Advan
ced Microfiber
M
esh™
{XImB© XoZo dmbo ‘¡b
Am¡a YmVw Ho$ Cn{OV
H$U H$mo {ZH$mbVm h¡ 
ESdm
ÝgS ‘mBH«$mo’$mB~a
‘oe™
G
ermkill Processor
™
9
setting up pureit Advanced
߶mo[aQ ESdmÝgS H$s ñWmnZm
Remove the Transparent Chamber with the
Pedestal and keep it aside.
Discard the plastic film from it.
Q´§mgna|Q Moå~a H$mo noSñQb Ho$ gmW {ZH$mb X| Am¡a Cgo
AbJ aI X|  D$na bJo ßbmpñQH$ {’$ë‘ H$mo ’|$H$ X| 
Open the box. Remove the Top Cover and keep it aside.
Remove and discard the thermocol.
Sã~o H$mo Imob|  Q°mn H$da H$mo {ZH$mbo Am¡a ~mOy ‘| aIo 
W‘m}H$mob H$mo {ZH$mbH$a ’|$H$ X| 
1 2
There is a bellow pump in the Top Chamber. Keep it in a safe place as you will need it later for cleaning.
Q°mn M¡å~a ‘| EH$ ~obmo n§n h¡  Bgo gwa{jV ñWmZ na aI X| ³¶mo{H$ g’$mB© Ho$ g‘¶ AmnH$mo BgH$s OéaV n‹SoJr 
CAUTION
10
Remove the Cleansing Collection Chamber,
Top Chamber and the Top Lid and keep it aside.
Discard the thermocol from the Top Chamber.
³boqµOJ H$bo³eZ Moå~a, Q°mn Moå~a Am¡a Q°mn {bS H$mo
{ZH$mb Ho$ AbJ go aI|  Q°mn Moå~a Ho$ AÝXa aIo hþE
W‘m}H$mob H$mo µ’|$H$ Xo 
3
Wash hands thoroughly. Remove the
Microcharged Membrane Assembly from
tamper proof pouch kept inside the Top Chamber.
hmWm| H$mo AÀNr Vah go Ymo¶|  Q°mn Moå~a Ho$ AÝXa aI|
W¡br go ‘mB©H«$moMmO©S ‘oå~«oZ H$mo {ZH$mb| 
4
setting up pureit Advanced
߶mo[aQ ESdmÝgS H$s ñWmnZm
11
setting up pureit Advanced
߶mo[aQ ESdmÝgS H$s ñWmnZm
Insert the Microcharged Membrane assembly at
the base of the Cleansing Collection Chamber.
Twist in clockwise direction to fit.
‘mB©H«$moMmO©S ‘oå~«oZ Ag|ãbr H$mo ³boqOJ H$bo³eZ Moå~a Ho$ ZrMo
bJm¶|  Xm§¶o Vaµ’$ ‘| Bgo ‘mo‹So {Oggo ¶h AÀNr Vah go bJ Om¶o 
5
Remove paper sleeve from the
Cleansing Collection Chamber.
nona ñbrd H$mo ³boqµOJ H$bo³eZ Moå~a
go {ZH$mb| 
6
Now place the Cleansing
Collection Chamber on the
Transparent Chamber.
³boqµOJ H$bo³eZ Moå~a H$mo
Q´m§gna|Q Moå~a Ho$ D$na aI| 
7
After fitting the Microcharged Membrane assembly to the Cleansing Collection Chamber, do not rest the
assembly on a flat surface.
‘mB©H«$moMmO©S ‘oå~«oZ Agoå~br H$mo ³boqµOJ H$bo³eZ Moå~a ‘| AÀNr Vah go bJmZo Ho$ ~mX Bgo g‘mZ gVh na Zm aIo 
Please remove the paper sleeve from the Cleansing Collection Chamber before use.
߶mo[aQ H$m Cn¶moJ H$aZo go nohbo H¥$n¶m nona ñbrd H$mo ³boqµOJ H$bo³eZ Moå~a go {ZH$mb| CAUTION
12
setting up pureit Advanced
߶mo[aQ ESdmÝgS H$s ñWmnZm
Place the Top Chamber on the Cleansing
Collection Chamber and the Top Cover
on the Top Chamber.
Q°mn Moå~a H$mo ³boqµOJ H$bo³eZ Moå~a Ho$ D$na
aI| Am¡a Q°mn H$da H$mo Q°mn Moå~a Ho$ D$na aI| 
Pour in water till the top of the Top Chamber and drain out all the
water that collects in the Transparent Chamber. Place the lid on the Top
Cover. Pureit Advanced is now ready for use from second cycle onwards.
Q°mn Moå~a Ho$ D$na VH$ nmZr ^ao Am¡a Q´mgna|Q Moå~a ‘| BH$Q²Rm hþE nmZr
H$mo {ZH$mb X|  Q°mn H$da H$mo {bS go T§H$ X|  ߶mo[aQ ESdmÝgS Xÿgao
gmBH$b go Cn¶moJ H$aZo Ho$ {bE V¡¶ma h¡ 
8 9
Please note that the first cycle will not give full 9L of water in the Transparent Chamber since some water gets
stored in the Cleansing Collection Chamber and the Top Chamber.
H¥$n¶m OmZ b| {H$ nhbo gmBH$b go Ûmam nyam 9 brQa nmZr Q´m§gna|Q Moå~a ‘| Zhr§ {‘boJm ³¶m|{H$ Wmo‹Sm gm nmZr ³boqµOJ H$bo³eZ
Moå~a Am¡a Q°mn Moå~a ‘| O‘m hmoVm h¡
13
ORDERINGTHE GERMKILL KIT™ (GKK)
O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZm
Once the Germkill Life Indicator™ turns fully red, please replace the Germkill Kit™ (GKK) immediately. As an
additional measure of safety, Auto Shut-Off™ mechanism of the Pureit Advanced, shuts off the supply of purified
water which ensures that no member of your family accidentally drinks unsafe water.
O‘©{H$b bmB’$ B§{SHo$Qa™ nyar Vah bmb hmo OmZo na H¥$n¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$) H$mo Vwa§V ~Xb X|  gwajm Ho$ A{V[aº$ ^amogo Ho$
Vm¡a na ߶mo[aQ H$m AmYw{ZH$ Am°Qmo eQ Am°’$™ V§Ì ߶moar’$m¶ {H$¶o hþE nmZr H$s gßbmB© ~§X H$a XoVm h¡ {Oggo gw[ZpíMV hmoVm h¡ H$s AmnHo$
n[adma H$m H$moB© gXñ¶ JbVr go Agwa{jV nmZr Z nr gHo$ 
There is an Auto Shut-Off™ overflow port provided on the Germkill Life Indicator™ cover. When the Germkill
Life Indicator™ is red, you might observe overflow from this port. Please replace the Germkill Kit™(GKK). Do
not pour any more water in theTop Chamber to avoid further spillage.
O‘©{H$b bmB’$ B§{SHo$Qa™ H$da na EH$ Am°Qmo eQ-Am°’$ Ûma àXmZ {H$¶m J¶m h¡  O~ O‘©{H$b bmB’$ B§{SHo$Qa™ bmb a§J H$m hmo OmVm
h¢, V~ Amn Bg Ûma go A{Vàdmh XoI gH$Vo h¢  H¥$n¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$) H$mo ~Xb X|  A{YH$ ZwH$gmZ go ~MZo Ho$ {bE Q°mn
Moå~a ‘| A{YH$ nmZr Z Smbo§ 
When Indicator shows white or partially red, the Germkill Kit™
(GKK) is working and it’s safe to use.
O~ B§{SHo$Qa Xem© ahm hmo gµ’o$X ¶m hëH$m gm bmb, BgH$m ‘Vb~ O‘©{H$b
{H$Q™ (Or Ho$ Ho$) H$m‘ H$a ahm h¡ Am¡a Cn¶moJ Ho$ [bE gwa{jV h¡ 
When Indicator shows mostly red, the Germkill Kit™ (GKK) is
nearing its end of life and its time to buy a new
Germkill Kit™ (GKK).
O~ B§{SHo$Qa Xem© ahm hmo A{YH$Va bmb, BgH$m ‘Vb~ O‘©{H$b {H$Q™
(Or Ho$ Ho$) IË‘ hmoZo dmbm h¡ Am¡a Z¶m O‘©{H$b {H$Q™  (Or Ho$ Ho$)
IarXZo H$m g‘¶ hmo J¶m h¡ 
When Indicator shows fully red, the Germkill Kit™ (GKK) has
exhausted and it is time to replace it.
O~ B§{SHo$Qa Xem© ahm hmo nyar Vah bmb, BgH$m ‘Vb~ O‘©{H$b {H$Q™
(Or Ho$ Ho$) H$s j‘Vm IË‘ hmo J¶r h¡ Am¡a O‘©{H$b {H$Q™ (Or Ho$ Ho$)
~XbZo H$m g‘¶ hmo J¶m h¡ 
Safe to use
Cn¶moJ Ho$ [bE gwa{jV
Time to buy a new
Germkill Kit™ (GKK)
Z¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$)
IarXZo H$m g‘¶ hmo J¶m h¡
Time to replace
~XbZo H$m g‘¶ hmo J¶m h¡
With advanced Auto Shut-OffTM
CAUTION
14
You can buy a Germkill Kit™ (GKK) in any
of the following ways
Amn {ZåZ{b{IV VarH$m| go Z¶m O‘©{H$b {H$QTM
(Or Ho$ Ho$)
IarX gH$Vo h¢
Visiting a shop
XþH$mZ go
Calling up Pureit helpline
߶mo[aQ hoënbmBZ na µ’$moZ H$ao
Ordering on the website
do~gmBQ na AmS©a H$a Ho$
1860-210-1000 www.pureitwater.com
ORDERINGTHE GERMKILL KIT™ (GKK)
O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZm
15
There are multiple Pureit Germkill Kit™(GKK) available. Please buy the one that is
recommended for your Pureit Advanced model.
߶mo[aQ Ho$ AZoH$ àH$ma Ho$ O‘©{H$b {H$Q™ (Or Ho$ Ho$) CnbãY h¢. H¥$n¶m AmnHo$ ߶mo[aQ ‘m°Sb ‘| {’$Q
hmoZo dmbr O‘©{H$b {H$Q™ (Or Ho$ Ho$) hr IarX| 
Microcharged Membrane
‘mB©H«$moMmO©S ‘oå~«Z
Germkill Processor™
O‘©{H$b àmogoga™
Carbon Polisher™
H$m~©Z nm{bea™
The Germkill Kit™ (GKK) consists
of 3 parts
O‘©{H$b {H$Q™ (Or Ho$ Ho$) ‘| 3 nwO} hmoVo h¢
ORDERINGTHE GERMKILL KIT™ (GKK)
O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZm
CAUTION
16
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
Remove Top Lid and clean it with tap water.
Leave it to drip dry.
Q°mn {bS H$mo {ZH$mbo§ Am¡a Cgo Zb Ho$ nmZr go
gmµ’$ H$a|  AÀNr Vah gyIZo Ho$ {bE aI X| 
1 2
Remove Top Cover and clean it with tap water.
Leave it to drip dry.
Q°mn H$da H$mo {ZH$mb| Am¡a Cgo Zb Ho$ nmZr go gmµ’$
H$a|  AÀNr Vah gyIZo Ho$ {bE aI X|
17
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
Slightly pull the Germkill Life Indicator™ Cover
upwards and remove it from the purifier.
O‘©{H$b bmB©µ’$ BpÝSHo$Qa™ H$da H$mo hëHo$ go Cna H$s
Vaµ’$ ItMo Am¡a Cgo ߶moar’$m¶a go {ZH$mb| 
43
Do not clean the hole in the Top Chamber with sharp objects.
Q°mn Moå~a Ho$ NoXm| H$mo ZwH$sbo dñVw go gmµ’$ Z H$a| 
Rinse the Top Chamber with clean water
and leave it to ‘drip dry’ in a clean place.
Q°mn Moå~a H$mo AÀNo gmµ’$ nmZr go Ymo¶| Am¡a
gwIZo Ho$ {bE {H$gr gmµ’$ OJh na aI| 
CAUTION
18
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
Empty the water from the
Cleansing Collection Chamber.
³boqµOJ H$bo³eZ Moå~a ‘| go nmZr
Imbr H$a X| 
Rotate the Germkill Processor™
in the anti-clockwise direction to
remove and keep it in a safe place.
O‘©{H$b àmogoga™ H$mo ~m§¶r Vaµ’$ Kw‘mH$a
{ZH$mb| Am¡a {H$gr gwa{jV OJh na aI| 
65
Wash hands thoroughly. Rotate the
Microcharged Membrane assembly in
anti-clockwise direction to remove.
Keep it aside in a clean place.
hmWm| H$mo AÀNr Vah go Ymo¶|  ‘mBH«$moMmO©S
‘oå~«oZ Agoå~br H$mo ~m§¶r Vaµ’$ ‘| Kw‘mH$a
{ZH$mb|  Cgo AbJ go {H$gr gmµ’$ OJh
na aI| 
7
19
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
8
Do not remove the Microcharged Membrane assembly without emptying water from the
Cleansing Collection Chamber.
³boqµOJ H$bo³eZ Moå~a go nmZr Imbr {H$E {~Zm ‘mBH«$moMmÁS© ‘oå~«oZ Ag|ãbr H$mo Z {ZH$mb| 
Rotate the Advanced Microfiber Mesh™ in the
anti-clockwise direction to remove.The Carbon
Polisher™ will come out along with it.
ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ H$mo ~m§¶o Vaµ’$ Kw‘m¶| 
H$m~©Z nm{bea™ CgHo$ gmW ~mha Am OmEJm 
Rotate the Carbon Polisher™ in the
anti-clockwise direction to remove.
H$m~©Z nm{bea™ H$mo ~m§¶o Vaµ’$ ‘| Kw‘mH$a {ZH$mb| 
9
CAUTION
20
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
Wash the Advanced Microfiber
MeshTM
under a jet of water.
ESdmÝgS ‘mBH«$mo’$mB~a ‘oeTM
H$mo
VoµO nmZr Ho$ ZrMo YmoE± 
10
Fill Pureit water in the Bellow Pump.
~obmo nån ‘| ߶mo[aQ nmZr ^a| 
11 12
Insert the Bellow Pump into the nozzle at
the bottom of the Carbon Polisher™, the
area opposite to side with handles given.
~obmo nån H$mo H$m~©Z nm{bea™ Ho$ ZrMo Zbr
‘| bJmE±  ¶o hoÝSb dmbr OJh Ho$ CëQo dmbr
OJh h¡
21
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
13 14
Clean the Cleansing Collection Chamber
with clean water and leave to drip dry.
³boqµOJ H$bog³eZ Moå~a H$mo gmµ’$ nmZr go YmoE±
Am¡a AÀNr Vah go gyIZo Ho$ {bE aI X| 
Close the mouth of the carbon block with one hand and squeeze the Bellow
Pump with the other hand to force the water through the carbon block. You
can see dirt coming out of the carbon block. Repeat procedure 5-6 times.
H$m~©Z ãbm°H$ Ho$ ‘w§h H$mo EH$ hmW go ~§X H$ao Am¡a ~obmo nån H$mo Xþgao hmW go X~m¶|
{Oggo {H$ H$m~©Z ãbm°H$ ‘| nmZr H$m X~md ~‹To  Amn XoI|Jo {H$ H$m~©Z ~bm°H$ go
‘¡b ~hma {ZH$mb ahm h¡  Bg à{H«$¶m H$mo 5-6 ~ma XmohamE±
You may observe some amount of water coming back through the Below Pump which can be pushed into the
Carbon Polisher™ again. Please clean the Carbon Polisher™ with the Bellow Pump multiple times for best results.
Amn XoI|Jo H$s Wmo‹Sr ‘mÌ ‘| nmZr ~obmo nån go ~mha Am ahm h¡ {Ogo nwZ… H$m~©Z nm{bea™ ‘| YHo$bm Om gH$Vm h¡  H$m~©Z
nm{bea™ H$mo H$B© ~ma ~obmo nån go Ymo b| {Oggo AÀNm n[aUm‘ {‘bo CAUTION
22
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
16
Replace the Advanced Microfiber
MeshTM
Assembly in the Cleansing
Collection Chamber by turning it
clockwise. Ensure tightness.
ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ Agoå~br
H$mo ³boqµOJ H$bo³eZ Moå~a ‘| Smb| Am¡a
Cgo Xm§¶o Vaµ’$ Kw‘m¶|  AmeñdV H$a| {H$
dmo g»V hmo§ 
Wash the Transparent Chamber with clean
Pureit water and ‘drip dry’.
Q´m§gna|Q Moå~a H$mo ߶mo[aQ nmZr go AÀNr Vah go
gm’$ H$a| Am¡a gyIZo Ho$ {bE Nmo‹So 
17
Replace the Carbon Polisher™ in
the Advanced Microfiber MeshTM
Assembly by turning it clockwise.
Ensure tightness.
ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ ‘| H$m~©Z
nm{bea™ H$mo Smb| Am¡a Cgo Xm§¶o Vaµ’$ ‘|
Kw‘m¶|  AmeñdV H$a| {H$ dmo g»V hm| 
15
23
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
18
Fill Pureit water in the Bellow Pump. Insert the
Bellow Pump into the nozzle provided at the
bottom of the Microcharged Membrane assembly.
~obmo nån ‘| ߶mo[aQ H$m nmZr ^a|  Cg ~obmo nån H$mo
ESdmÝgS ‘mBH«$moMmÁS© Agoå~br Ho$ Vb no Xr JB©
Zbr ‘| Kwgm¶| 
In case your water quality is very bad and the flow rate does not improve on cleansing the Advanced Microfiber Mesh™ and the
Carbon Polisher™ you need to clean the Microcharged Membrane as shown above.
AJa nmZr ~hþV Á¶mXm Iam~ hmo Am¡a ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ H$m~©Z nm{bea™ H$s gµ’$mB© Ho$ ~mX ^r nmZr H$m ~hmd VoµO Zm hmo Vmo {’$a
‘mBH«$moMmÁS© ‘oå~«oZ H$mo D$na {XIm¶o J¶o VarHo$ go gmµ’$ H$a| 
Now hold the Microcharged Membrane base and squeeze the Bellow
Pump to force water out of the Microcharged Membrane assembly. You
can see dirt coming out of the membrane. Repeat procedure 5-6 times.
A~ ‘mBH«$moMmÁS© ‘oå~«oZ Ho$ Vb H$mo nH$S| Am¡a ~obmo nån H$mo X~m¶|, Vm{H$ nmZr nyar
VoµOr go ‘mBH«$moMmÁS© ‘oå~«oZ Agoå~br go ~mha {ZH$b|  Amn ‘oå~«oZ go {ZH$bVr hþB©
J§XJr H$mo XoI gH$Vo h¢  Bg H$m¶©{dÜmr H$mo 5-6 ~ma Xmoham¶| 
19
While cleaning the Microcharged Membrane, please ensure your hands are germ free.
‘mBH«$moMmÁS© ‘oå~«oZ gmµ’$ H$aVo dº$ ܶmZ aI| {H$ AmnHo$ hmW H$sQmUw ‘wº$ hm| 
CAUTION
24
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
21
Replace Cleansing Collection Chamber
on the Transparent Chamber.
Q´m§gna|Q Moå~a Ho$ D$na ³boqµOJ H$bo³eZ
Moå~a H$mo aI| 
20
Insert the Microcharged Membrane assembly at
the base of the Cleansing Collection Chamber
and turn clockwise to fit. Ensure tightness.
‘mBH«$moMmÁS© ‘oå~«oZ Ag|ãbr H$mo ³boqµOJ H$bo³eZ
Moå~a Ho$ ZrMo Xm§¶o Vaµ’$ ‘| Kw‘mH$a Smb|  AmídñV
H$a| H$s dh g»V hmo
25
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
22
Insert the Germkill Processor™ and turn in
clockwise direction to fit. Ensure tightness.
O‘©{H$b àmogoga™ H$mo Kwgm X| Am¡a Cgo Xm§¶o Vaµ’$
‘| Kw‘mH$a bJm X|  AmœñV hmo {H$ AÀNr Vah go
bJ J¶m hmo 
23
Place the Germkill Life Indicator™ Cover in the
grooves provided on the Cleansing Collection
Chamber and push it downwards to fit.
O‘©{H$b bmBµ’$ BpÝSHo$Qa™ H$da H$mo ³boqµOJ H$bo³eZ Moå~a
na ~Zm¶o J¶o Im§Mo ‘| aI| Am¡a Cgo ZrMo {IgH$m Ho$ AÀNr
Vah bJmE±
26
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
25
Replace the Top Cover and Top Lid on
the Top Chamber.
Q°mn Moå~a Ho$ D$na Q°mn H$da Am¡a Q°mn {bS H$mo aI| 
24
Replace the Top Chamber on the Cleansing
Collection Chamber.
³boqµOJ H$bo³eZ Moå~a Ho$ D$na Q°mn Moå~a H$mo aI|
27
Cleaning  maintenance of Pureit Advanced
߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd
Clean the mouth of the tap with dilute disinfectant like bleach/hypochlorite (50 ppm available chlorine). Pour
in water till the top of the Top Chamber and drain out all the water that collects in the Transparent Chamber.
Refill the Top Chamber. Pureit Advanced is now ready for use from second cycle onwards.
ãbrM/hmBnmo³bmoamBS (50 nrnrE‘ CnbãY ³bmoarZ) O¡go H$sQmUwZmeH$ Ho$ Cn¶moJ go Zb
Ho$ Ûma H$mo gm’$ H$a|  Q°mn Moå~a H$mo nmZr go ^a| Am¡a Q´m§gna|Q Moå~a ‘| O‘m hþE nmZr H$mo
µ’|$H$ X|  Q°mn Moå~a ‘| {’$a go nmZr ^a X|  ߶mo[aQ ESdmÝgS A~ BñVo‘mb Ho$ {bE V¡¶ma h¡ 
26
28
dos  don’ts
Pureit Advanced has been specially designed to give you water that is ‘SaferThan Boiled Water’ as long as
the Pureit Advanced system is used in the way as prescribed in this manual.
Listed below are the things that you must take care of:
   DO’s    DON’Ts
Clean the Top Lid, the Top Chamber, the Cleansing Collection Chamber and
the tap regularly
Clean with water and then leave the components to ‘drip dry’
Clean the tap with a mild hypochlorite solution
If necessary, use a plastic brush to aid cleaning
Remove the Germkill Processor™ while cleaning and keep upright in a
separate dry place
Empty the water from the Cleansing Collection Chamber before removing the
Microcharged Membrane assembly
Remove the Germkill Processor™ before emptying out the water from the
Cleansing Collection Chamber
The Pureit guarantee of getting water that is ‘Safer Than Boiled Water’
applies only if you ensure that the Transparent Chamber of the purifier and
the tap are hygienically kept, and that germs are not introduced due to
contact with hands, drying with a cloth, wash or any other means
You should only store water in Pureit Advanced purifier and not use other
bottles and containers, to avoid re-contamination of the water
Always use all three components of the Pureit Advanced Germkill Kit™
together
You should ensure that the area around and beneath the purifier is kept
clean at all times
Keep all components of the Pureit Advanced Germkill Kit™ out of reach of
children at all times
Do not clean with soap or detergent, or any abrasive cleaners or tools like wire Mesh
Do not twist the Advanced Microfibre Mesh™ while cleaning. The Advanced
Microfiber Mesh™ might change its color over a period of time. This does not
affect the performance of the Advanced Microfiber Mesh™
Do not use any soap or detergent. Ensure that you don’t inadvertently introduce
germs into the Transparent Chamber or the tap e.g. through your hands or by
using a drying cloth. Always use purified Pureit Advanced water for doing the last
rinse of the Transparent Chamber, and then let it drip-dry
Do not normally wash the Cleansing-Collection Chamber
Don’t pour boiling or hot water (more than 50˚C) into, or on the Pureit Advanced
system. Similarly don’t pour freezing cold water (less than 10˚C) into, or on the
Pureit Advanced system
Do not pour hot water directly from an overhead tank or any other source in your
Pureit Advanced as hot water uses up the Germkill Kit™ faster than normal. If
required, allow the water to cool to room temperature before pouring it in the Top
Chamber. For the same reason do not keep your Pureit Advanced in hot surroundings
like direct sunlight, near a stove or near a fridge
Never buy the Pureit Advanced system, or a Pureit Advanced Germkill Kit™ from an
unauthorized source.You can visit a store near you to buy a Germkill Kit™ or call us
at the Pureit helpline, and we will deliver a new Germkill Kit™ to you at your home
for a minimal delivery charge
Don’t in any way try to open the three Pureit Advanced Germkill Kit™
components
Never use the system once the Pureit Advanced Germkill Life Indicator™ shows a
full red colour in the window, with no white colour visible
Don’t expose any of the components to fire
29
dos  don’ts
Pureit Advanced has been specially designed to give you water that is ‘SaferThan Boiled Water’ as long as
the Pureit Advanced system is used in the way as prescribed in this manual.
Listed below are the things that you must take care of:
   DO’s    DON’Ts
Ensure that the purifier is placed on a flat surface at all times, and never
tilt the Transparent Chamber to take out water
If you ever want to shift the purifier, do so only after both the Top Chamber
and Cleansing Collection Chamber are empty. Otherwise the purifier may leak,
and the purification process may get affected
Always rely only on the red Indicator to replace the Germkill Kit™. The
Auto Shut-Off™ is only an additional assurance of safety – in some cases,
the input water quality may prevent it from functioning
Freshly purified water should be used for drinking
Output water may continue to have flora which are harmless and pose no
health hazard to normal healthy adults and children
Always clean the Pureit Advanced system only as described in the section
on cleaning
Don’t drop any of the components, or the purifier as a whole from a height. This
may cause the components to fracture or break, and the guarantee of getting
water ‘Safer Than Boiled Water’ will no longer be valid
Don’t put any chemical fluids in the Pureit Advanced system. This is meant strictly
for drinking water only
If the Transparent Chamber is full, please do not fill water in the Top Chamber,
otherwise water will overflow from the Transparent Chamber
Do not try to open the Germkill Processor™
Do not pour water in purifier after Germkill Life Indicator™ turns fully red.
This will prevent water overflowing due to Auto Shut-Off™. This ensures no one
is accidentally hurt by slipping on the water. Also, no household item kept near
purifier would get damaged by leaked water
Do not use the Germkill Kit™ after expiry – which is post two years from the
date of packing
Do not keep the Pureit Advanced purifier in direct sunlight as it may trigger
growth of algae if input water is significantly contaminated
Do not use water not intended for drinking in Pureit Advanced system e.g., from
abandoned or abused water bodies or water sources in which human, animal or
industrial wastes are disposed, or water that is excessively acidic or alkaline
Water stored for more than two days should not be consumed
Do not remove the Batching Chamber from the Cleansing Collection Chamber. If
it gets removed accidentally, then replace the parts in proper location, as was
assembled initially for consistent performance
Do not meddle with the Microcharged Membrane else it will get damaged and you
might get unsafe water
Don’t drink water from the purifier if any one of the Germkill Kit™ components
is not fitted
Do not allow any foreign or unexpected material (like dust, ants, insects, other
pests) to enter into the storage tank. The purified water in the storage tank may
deteriorate in the process.
30
³¶m H$a| Am¡a ³¶m Zht
߶mo[aQ H$mo Bg àH$ma {SOmB©Z {H$¶m J¶m h¢ H$s O~ VH$ Amn CgH$m à¶moJ Bg nwpñVH$m Ho$ AZwgma H$a|Jo V~ VH$ Amn H$mo ‘C~bo nmZr go
µÁ¶mXm gwa{jV nmZr’ {‘bVm ahoJm  {ZåZ{b{IV MrOm| na ܶmZ X| 
   ³¶m H$a|    ³¶m Z H$a|
Q°mn {bS, Q°mn Moå~a, ³bo{µOJ H$bo³eZ Moå~a Am¡a Q¡n {Z¶{‘V én™ go gmµ’$ H$a| 
nmZr go gmµ’$ H$ao Am¡a {’$a nwOm} H$mo AÀNr Vah go gyIZo Ho$ {bE Nmo‹S Xo 
Q¡n H$mo hëH$m hmBnmo³bmoamBQ gmoë¶yeZ go gmµ’$ H$a| 
µOéaV n‹SZo na g’$mB© Ho$ {bE EH$ ßbmpñQH$ ~«e H$m Cn¶moJ H$a| 
g’$mB© Ho$ Xm¡amZ O‘©{H$b àmogoga™ àH$aU H$mo hQm X| Am¡a EH$ AbJ gyIr OJh na
grYm aI| 
‘mBH$moMmÁS© ‘oå~«oZ Ag|ãbr H$mo hQmZo go nhbo ³boqµOJ H$bo³eZ Moå~a go nmZr {ZH$mb
X| 
³boqµOJ H$bo³eZ Moå~a ‘| go nmZr Imbr H$aZo go nhbo, O‘©{H$b àmogoga™ {ZH$mb| 
‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bZo H$s J°maÝQr Ho$db V~ bmJy hmoJr AJa Amn
gw{ZpíMV H$aVo h¢ {H$ ߶w[a’$m¶a H$m Q´m§gna|Q M|å~a VWm Zb gm’$-gwWao aI| JE h¢,
VWm hmW, H$n‹So go gwImZo, YmoZo ¶m Aݶ {H$gr ^r VarHo$ go {H$QmUwAm| Ho$ gånH©$ ‘|
Z Am¶m hmo 
AmnH$mo Ho$db ߶mo[aQ ESdmÝgS ߶w[aµ’$¶a ‘| hr nmZr g§J«{hV H$aZm Mm{hE Am¡a nmZr H$mo
nwZ… àXÿ{fV hmoZo go ~MmZo Ho$ {bE Aݶ ~moVb Am¡a ~V©Z H$m Cn¶moJ Zht H$aZm Mm{hE 
߶mo[aQ ESdmÝgS O‘©{H$b {H$Q™ Ho$ g^r VrZ nwO} EH$gmW BñVo‘mb H$a| 
gw{ZpíMV H$a| H$s ߶w[a’$m¶a Ho$ BX©-{JX© H$m joÌ gm’$ h¡ 
߶mo[aQ ESdmÝgS O‘©{H$b {H$Q™ Ho$ g^r nwO} h‘oem ~ƒm| {H$ nhþ§M go Xÿa aI| 
gw{ZpíMV H$a| H$s AmnH$m ߶w[a’$m¶a h‘oem g‘Vb aho, VWm nmZr {ZH$mbZo Ho$ {bE
Q´m§gna|Q Moå~a H$mo Z PwH$mE§ 
AJa Amn ߶w[a’$m¶a H$mo Xÿgar OJh aIZm MmhVo h¢ Vmo ¶o gw{ZpíMV H$a b| H$s Q°mn
Moå~a VWm ³boqµOJ H$bo³eZ Moå~a XmoZm| hr Imbr hmo  AݶWm ߶w[a’$m¶a go [agmd hmo
gH$Vm h¡, VWm nw[a{’$Ho$eZ H$s à{H«$¶m ~{YV hmo gH$Vr h¡ 
gm~wZ ¶m {SQO}Q AWdm H$moB© AnKf©H$ g’$mB© CnH$aU O¡go Vma H$s Ombr go
gmµ’$ Z H$a| 
g’$mB© H$aVo dµ³V ESdmÝgS ‘mBH«$mo ’$mB~a ‘oe™ H$mo Z ‘mo‹So  g‘¶ OmVo
ESdmÝgS ‘mBH«$mo’$moB~a ‘oe H$m a§J ~Xb gH$Vm h¡  Bggo ESdmÝgS ‘mBH«$mo’$mB~a
‘oe H$m H$m¶©àXe©Z à^m{dV Zhr hmoVm h¡ 
{H$gr ^r gm~wZ ¶m {SQaOÝQ H$m BñVo‘mb Z H$a|  gw{ZpíMV H$a b| H$s Q´m§gna|Q
Moå~a ¶m Zb ‘o§ AÝOmZo ‘| ^r {H$QmUw àdoe Z H$a| CXm…- AmnHo$ hmW ¶m gwImZo
dmbo H$n‹So go  Q´m§gna|Q Moå~a H$mo AmIar ~ma YmoZo Ho$ {bE h‘oem ߶w[a’$mB©S
߶mo[aQ ESdmÝgS nmZr H$m hr BñVo‘mb H$a|, Am¡a {’$a go gyIZo Ho$ {bE aIo 
³b|qOJ H$bo³eZ Moå~a H$mo Am‘ Vm¡a na gm’$ Z H$a| 
߶mo[aQ ESdmÝgS {gñQ‘ ‘|, ¶m Cg na C~bVm hþAm ¶m Ja‘ nmZr
(500
C A{YH$ Vmn‘mZ) Z Smb|  gmW hr ߶mo[aQ ESdmÝgS {gñQ‘ ‘|, ¶m CgHo$
Cna O‘m XoZo dmbm R§Sm nmZr (100
C H$‘) Z Smb| 
AmnHo$ ߶mo[aQ ESdmÝgS ‘| {H$gr AmodahoS Q§H$s ¶m Aݶ {H$gr ómoV go grYm Ja‘
nmZr Z Smb| ³¶mo{H$ Ja‘ nmZr O‘©{H$b {H$Q™ H$s InV gm‘mݶ go A{YH$ J{V
go H$aVm h¡  Amdí¶H$ hmo Vmo nmZr H$mo Q°mn Moå~a ‘o SmbZo go nhbo Cgo gm‘mݶ
Vmn‘mZ VH$ AmZo X|  Bgr H$maU go AmnHo$ ߶mo[aQ ESdmÝgS H$mo grYo gyaO H$s
amoeZr ‘|, ñQmod Ho$ ¶m {’«$O Ho$ nmg Z aIo 
H$^r ^r {H$gr AZm{YH¥$V ómoV go ߶mo[aQ ESdmÝgS {gñQ‘, ¶m ߶moaBQ O‘©{H$b
{H$Q™ Z IarXo§  Amn AmnHo$ H$ar~r ñQmoa go O‘©{H$b {H$Q™ IarX gH$Vo h¡
¶m ߶mo[aQ hoënbmB©Z go gånH©$ H$a| Am¡a h‘ Zm‘‘mÌ {Sbrdar ewëH$ na EH$ Z¶m
O‘©{H$b {H$Q™ AmnHo$ Ka nhþ±Mm X|Jo 
߶mo[aQ ESdmÝg‹S O‘©{H$b {H$Q™ Ho$ VrZ nwOm} H$mo {H$gr ^r VarHo$ go ImobZo H$s
H$mo{ee Z H$a| 
߶mo[aQ O‘©{H$b ESdmÝgS bmB’$ B§{SHo$Qa™ nyar Vah go bmb {XI ahm hmo, Am¡a
g’o$X a§J {~ëHw$b {XImB© Z Xo ahm hmo V~ Bg {gñQ‘ H$m H$VB© BñVo‘mb Z H$a|
31
³¶m H$a| Am¡a ³¶m Zht
߶mo[aQ H$mo Bg àH$ma {SOmB©Z {H$¶m J¶m h¢ H$s O~ VH$ Amn CgH$m à¶moJ Bg nwpñVH$m Ho$ AZwgma H$a|Jo V~ VH$ Amn H$mo ‘C~bo
nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bVm ahoJm  {ZåZ{b{IV MrOm| na ܶmZ X| 
   ³¶m H$a|    ³¶m Z H$a|
O‘©{H$b {H$Q™ ~XbZo Ho$ {bE h‘oem Ho$db bmb BpÝSHo$Qa na hr ^amogm aI| Am°Qmo
eQ-Am°’$™ Ho$db gwajm H$m EH$ A{Varº$ ^amogm h¡ - Hw$N ‘m‘bm| ‘|, AmZodmbo nmZr
H$s JwUdÎmm CgHo$ H$m¶© ‘| éH$mdQ bm gH$Vr h¡ 
nrZo Ho$ {bE VmOm ewÕ {H$¶m J¶m nmZr hr Cn¶moJ H$aZm Mm{hE 
V¡¶ma nmZr ‘| âbmoam hmo gH$Vo h¡ Omo ZwH$gmZH$mar Zht Am¡a Omo gm‘mݶ ñdmñ϶ dmbo
d¶ñH$m| d ~mbH$m| Ho$ ñdmñ϶ Ho$ {bE {H$gr àH$ma H$m IVam Zht hmoVo h¢ 
߶mo[aQ ESdmÝgS {gñQ‘ H$mo Ho$db g’$mB© Ho$ go³eZ ‘| {H$E JE dU©Z Ho$ AZwgma hr
gm’$ H$a| 
gmao nwOm} H$mo AmJ go Xÿa aI| 
H$moB© ^r nwOm©, ¶m ߶w[a’$m¶a H$mo D±$MmB© go Z {JamE±  Bggo nwO} ’«°$³Ma hmo gH$Vo h¢
¶m QyQ gH$Vo h¢, Am¡a ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bZo H$s J°maÝQr AmJo
d¡Y Zhr ahoJr 
߶mo[aQ ESdmÝgS {gñQ‘ ‘| H$moB© ^r Ho${‘H$b Z Smb|  ¶h Ho$db nrZo Ho$ nmZr
Ho$ {bE hr h¡ 
AJa Q´m§gna|Q Moå~a ^a J¶m hmo, Vmo H¥$n¶m Qm°n Moå~a ‘| nmZr Z ^a| AݶWm nmZr
Q´m§gna|Q Moå~a go ~mha ~hZo bJoJm 
O‘©{H$b àmogoga™ H$mo ImobZo H$m à¶mg Z H$a| 
O‘©{H$b bmB’$ B§{SHo$Qa™ H$m a§J bmb hmo OmZo Ho$ ~mX ߶w[a’$m¶a ‘| nmZr Z
Smb| Bggo Am°Qmo eQ-Am°’$™ g{H«$¶ hmo OmZo go nmZr Amodaâbmo Zhr hmoJm Am¡a
nmZr na go {H$gr Ho$ {’$gbZo H$s ¶m ߶moar’$m¶a Ho$ Amg nmg aIo {H$gr gm‘mZ Ho$
˜am~ hmoZo H$s g§^mdZm Zht ahoJr 
O‘©{H$b {H$Q™ H$s OrdZ Ad{Y IË‘ hmoZo Ho$ ~mX CgH$m BñVo‘mb Z H$a| -
n¡qH$J Ho$ níMmV Xmo gmb VH$ ¶h Ad{Y hmoVr h¡ 
߶mo[aQ ESdmÝgS ߶w[a’$m¶a H$mo grYo gyaO H$s amoeZr ‘| Z aI|  nmZr A{YH$
Xÿ{fV hmoZo H$s pñWVr ‘| Bg‘| e¡dmb H$m {dH$mg hmo gH$Vm h¡ 
Omo nmZr nrZo Ho$ {bE Z hmo Cgo ߶mo[aQ ESdmÝgS {gñQ‘ ‘| Z Smbo CXm. A˶{YH$
Amåbr¶ ¶m jmar¶ nmZr ¶m BñVo‘mb ‘| Z AmZo dmbm ¶m Iam~ Obme¶ ¶m
ObómoV H$m Eogm nmZr {OZ‘o ‘Zwî¶, àmUr ¶m H$maImZm| H$m H$Mam Smbm OmVm hmo 
Xmo {XZm| go A{YH$ Ad{Y H$m g§J«{hV Ob Cn¶moJ ‘| Zht b| 
~°qMJ Moå~a H$mo ³boqµOJ H$bo³eZ Moå~a go Z hQm¶o  AJa dh hQ Om¶o Vmo Cgo
AnZr OJh no RrH$ go bJm Xo, O¡go dmo nhbo bJm hþAm Wm 
‘mBH«$moMmÁS© ‘oå~«oZ go Z CbPo, Zht Vmo dh j{VJ«ñV hmo Om¶oJm Am¡a AmnH$mo nrZo Ho$
{bE Agwa{jV nmZr {‘b gH$Vm h¡ 
O‘©{H$b {H$Q™ H$m H$moB© nwOm© bJm¶m Z hmo Eogr pñWVr ‘| ߶w[a’$m¶a go nmZr Z {nE§ 
Q´m§gna|Q M¢~a ‘| {H$gr ^r {dXoer ¶m Aà˶m{eV gm‘J«r (Yyb, Mt{Q¶m|, H$s‹So, Aݶ
Vah Ho$ H$sQ) H$mo àdoe H$aZo Z X|  Bg à{H«$¶m go Q´m§gna|Q M¢~a H$m ߶moarµ’$mBS
nmZr Iam~ hmo gH$Vm h¡
32
FAQs
There is condensation in theTransparent Chamber. Is
this a problem?
This normally happens because of temperature differences. It
does not affect the working of your Pureit Advanced and you
will continue to receive water that is ‘Safer Than Boiled Water’.
What happens if some part of the Pureit Advanced
breaks accidentally?
If some part of Pureit Advanced breaks accidentally, please
call Pureit Advanced helpline.We will arrange to send you
a replacement part.You will however have to pay for the
replacement part.
What should I do if it takes a long time to
purify water?
In case the water quality is bad the filtration units of Pureit
Advanced may take a longer time to purify water. In such
cases you will need to clean the Carbon Polisher™ and
the Advanced Microfiber MeshTM
. Please refer the ‘Cleaning
 Maintenance of Pureit Advanced’ section for this. If the
flow rate still does not improve them please clean the
Microcharged Membrane as shown in the ‘Cleaning 
Maintenance’ section.
How do I know that my Pureit Advanced
needs cleaning?
In case the water quality is bad the filtration units of Pureit
Advanced may take a longer time to purify water.There will
be a time when the water stops coming into the Transparent
Chamber.This is an indication that you need to clean your
Pureit Advanced. Please refer the ‘Cleaning  Maintenance of
Pureit Advanced’ section for this.
Pureit Advanced didn’t fully remove the colour from
the input water. Is the water safe to drink?
Such a situation will normally not happen in PureitAdvanced.
All the colloidal clay,insoluble salts of calcium,magnesium,iron
etc will be removed by the Microcharged Membrane.Such a
situation if happens,suggests that Microcharged Membrane
has been damaged.Please call the PureitAdvanced helpline for
replacement.
Can there be scaling in Pureit Advanced?
Dissolved chemicals in water can occasionally precipitate out of
the water,and deposit inside PureitAdvanced.This however does
not in any way affect the Germkill capability of PureitAdvanced.
To avoid scaling,rinse theTop Chamber Transparent Chamber
once in a while.Do not use any abrasive cleaners or tools.Refer
to Cleaning  Maintenance of PureitAdvanced section for details.
33
FAQs
Will Pureit Advanced remove salt and oil?
Input water may contain many materials which affect the taste
of water. Of these, Pureit Advanced removes materials like
oil, sand, soil, clay, dirt, decayed animal and plant waste, and
harmful pesticide impurities and is therefore likely to improve
the taste of water. However, Pureit Advanced does not
remove some dissolved salts that may contribute to taste like
sodium chloride salt, calcium and magnesium.
In fact, Pureit Advanced retains some ‘good’ dissolved salts
present in drinking water. This may affect the taste of water.
Can one pour brackish water into Pureit Advanced?
Yes, the water will be free of harmful germs, but there may
not always be an improvement in taste. However by pouring
brackish/sea water into the Pureit Advanced, there may
be a risk of choking the system, and the ‘Auto Shut-Off™’
mechanism may malfunction.
Can there sometimes be particles in the water stored
in theTransparent Chamber?
No. Particles will not escape into the Transparent Chamber
through the filtering media. However you have to drain the
first cycle that gets collected in the Transparent Chamber.
Sometimes there is a chlorine like smell near the
Germkill Processor™. Is this a problem?
No, this is not a problem.You will continue to get absolutely
safe, odour free, great tasting water from the Transparent
Chamber.
Water is overflowing from the front of the purifier?
There might be two reasons for this. One, check your
Germkill Life Indicator™. If it is red, then please order for
a new Germkill Kit™ and replace it. Do not pour any more
water in the Top Chamber to avoid further spillage.Two, if
the Germkill Indicator is not red, please clean the Carbon
Polisher™ and the Advanced Microfiber MeshTM
and ensure
proper placement of all parts in the Cleansing Collection
Chamber. If the problem persists, then please contact Pureit
Advanced Helpline.
How long does it take for the water to get purified?
It depends on the quality of water that is put into Pureit
Advanced.Typically 9 litres of water gets purified between
1.5-2 hrs.
Cleaning the Carbon Polisher™ and the Advanced Microfiber
MeshTM
regularly can also improve the flow rate.
Do I need to empty the water from PureitAdvanced
if I am not using the purifier for a few days.
If there is stagnant water in Pureit Advanced for more than
2 days, then discard one cycle of water and start consuming
from the fresh cycle of water.
34
A³ga nyNo OmZo dmbo gdmb
Q´m§gna|Q Moå~a ‘| H§$SoÝgoeZ hþAm h¡  ³¶m ¶h EH$ g‘ñ¶m h¡?
Vmn‘mZ ‘| ’$H©$ Ho$ H$maU Am‘Vm¡a na Eogm hmoVm h¡  Bggo AmnHo$
߶mo[aQ ESdmÝgS Ho$ H$m¶© na Aga Zht hmoJm Am¡a AmnH$mo ‘C~bo nmZr
go µÁ¶mXm gwa{jV nmZr’ {‘bZm Omar ahoJm 
߶mo[aQ ESdmÝgS H$m H$moB© nwOm© hmXgo ‘| AMmZH$ QyQ J¶m Vmo ³¶m hmoJm?
߶mo[aQ ESdmÝgS H$m H$moB© nwOm© AJa hmXgo ‘| QyQ J¶m Vmo H¥$n¶m
߶mo[aQ ESdmÝgS hoënbmB©Z H$mo H$m°b H$a|  h‘ CgHo$ ~Xbo Xÿgam
nwOm© ^oOZo {H$ ì¶dñWm H$a|Jo  hmbm§{H$ Cg ~Xbo hþE nwO} H$s H$s‘V
MwH$mZr hmoJr
AJa nmZr ewÕ hmoZo ‘| Á¶mXm g‘¶ bJVm h¡ Vmo ‘wPo ³¶m H$aZm Mm{hE?
“AJa nmZr H$s J{V ‘| {µ’$a ^r ~TmoVr Zht AmVr h¡ Vmo ‘mBH«$moMmÁS©
‘oå~«oZ ‘߶mo[aQ ESdmÝgS H$s gµ’$mB© Am¡a aI aImd Ho$’ g§X^© ‘| gmµ’$
H$a|” 
‘wPo H¡$go nVm MboJm {H$ ‘oar ߶mo[aQ ESdmÝgS H$mo g’$mB© H$s OéaV h¡ ?
¶{X nmZr H$s JwUdÎmm ~hþV Iam~ h¡ Vmo nmZr ewÕ H$aZo ‘| ~hþV g‘¶
bJ gH$Vm h¡  Hw$N g‘¶ ‘| Q´m§gna|Q M|~a ‘| nmZr AmZm ~§X hmo Om¶oJm
 ¶h Bg ~mV H$m g§Ho$V h¡ {H$ AmnH$mo AnZo ߶mo[aQ ESdmÝgS {H$
g’$mB© H$aZr Mm{hE  H¥$n¶m BgHo$ {bE ‘߶mo[aQ ESdmÝgS H$s g’$mB©
Am¡a aI aImd’ IÊS H$m g§X^© b| 
߶mo[aQ ESdmÝgS Zo AÝXa AmZo dmbo nmZr go a§J nyar Vah go Zhr
{ZH$mbm  ³¶m dh nmZr nrZo Ho$ {bE gwa{jV h¡ ?
Eogr pñW{V ߶mo[aQ ESdÝgS ‘| CËnÝZ Zhr hmoJm g~ {‘År VWm
H¡$pëg¶‘, ‘½Zo{g¶‘ Am¡a bmohm Ho$ AKwbZerb bdU H$mo ‘mBH«$moMmÁS©
‘oå~«oZ ~mha {ZH$mb XoVm h¡  O~ Eogr pñW{V CËnÞ hmo Vmo g‘P bmo
H$s ‘mBH«$moMmÁS© ‘oå~«oZ j{VJ«ñV hmo MwH$m h¡  H¥$n¶m Bgo ~XbZo Ho$ {bE
߶mo[aQ ESdmÝgS hoënbmB©Z go g§nH©$ H$a| 
³¶m nmo[aQ ESdmÝgS ‘| ñHo$qbJ (jma H$s naV) hmo gH$Vr h¡?
nmZr ‘| ^§J agm¶Z H$^r H$^r nmZr go ~mha VbNQ H$a gH$Vo h¢,
Am¡a ߶mo[aQ ESdmÝgS Ho$ A§Xa O‘m hmo gH$Vo h¢  ¶h, {H$gr ^r Vah
go ߶mo[aQ ESdmÝgS H$s O‘©{H$b j‘Vm H$mo à^m{dV Zht H$aVm h¡ 
ñHo$qbJ amoH$Zo Ho$ {bE H$^r H$^r Q´m§gna|Q M¡å~a Am¡a Q°mn M¡å~a H$s
g’$mB© H$s{OE {H$gr ^r AnKf©H$ ³brZa ¶m CnH$aUm| H$m Cn¶moJ Z
H$a|  {ddaUm| Ho$ {bE ‘߶mo[aQ ESndmÝgS H$s g’$mB© Am¡a aI aImd’
IÊS go g§X^© b| 
³¶m ߶mo[aQ ESdmÝgS jma VWm Vob {ZH$mb nmEoJm?
߶mo[aQ ESdmÝgS ‘| Smbo OmZodmbo nmZr ‘| H$B© nXmW© hmo gH$Vo h¢ Omo
nmZr Ho$ ñdmX na Aga SmbVo h¢  BZ‘| go ߶mo[aQ ESdmÝgS Vob, aoVr,
{‘År, Yyb, àmUr VWm dZñnVr¶m| H$m g‹Sm hþAm H$Mam, Am¡a hm{ZH$maH$
35
A³ga nyNo OmZo dmbo gdmb
H$sQZmeH$ AewÕ VËd O¡go nXmW© hQm XoVm h¡ VWm Bggo nmZr Ho$
ñdmX ‘| ~ohVar hmo gH$Vr h¢  hmbm§{H$, ߶mo[aQ ESdmÝgS no¶Ob ‘|
CnpñWV Hw$N Kwbo hþE jma O¡go gmo{SA‘ ³bmoamB©S g°mëQ, H$°pëe¶‘
VWm ‘°½Zo{e¶‘ H$mo Zht {ZH$bVm h¡ Am¡a Hw$N bm^H$mar Kwbo hþE jma H$mo
߶mo[aQ ESdmÝgS ~aH$ama aIVm h¡  Bggo nmZr Ho$ ñdmX na à^md n‹S
gH$Vm h¡ 
³¶m h‘ ߶mo[aQ ESdmÝgS ‘| Z‘H$sZ nmZr Smb gH$Vo h¢?
Or hm§, ¶h nmZr hm{ZH$maH$ {H$QmUwAm| go ‘w³V hmoJm, bo{H$Z CgHo$
ñdmX ‘| h‘oem ~ohVar hmoJr Eogm Zhr h¡  g‘wÐ Ho$ Imam nmZr H$mo ߶mo[aQ
ESdmÝgS ‘| SmbZo go ¶ÝÌ ‘| KwQZ CËnÝZ hmo gH$Vm h¡ Am¡a Am°Qmo
eQ-Am°µ’$™ V§Ì H$s Iam~r hmo gH$Vr h¡ 
Q´m§gna|Q Moå~a ‘| O‘m {H$E JE nmZr ‘| ³¶m H$^r H$U hmo gH$Vo h¢ ?
Zht  {µ’$ëQatJ ‘mܶ‘ go Q´m§gna|Q Moå~a ‘| H$moB© ^r H$U Zht OmEJm
{µ’$a ^r AmnH$mo Q´m§gna|Q Moå~a ‘| nhbo gmBH$b ‘| EH${ÌV nmZr H$mo
{ZH$mb XoZm Mm{hE 
H$^r - H$^r O‘©{H$b àmogoga™ Ho$ nmg ³bmoarZ O¡gr J§Y AmVr h¡,
³¶m ¶o H$moB© g‘ñ¶m Vmo Zht h¡ ?
Or Zht, ¶h H$moB© g‘ñ¶m Zht h¡  AmnH$mo Q´m§gna|Q M|~a go Cgr
Vah gmµ’$ - ñdÀN, ~ohVarZ ñdmX dmbm Am¡a J§Y a{hV nmZr
{‘bVm ahoJm 
nmZr ߶mo[a’$m¶a Ho$ gm‘Zo go Amodaâbmo hmo ahm h¡ ?
BgHo$ Xmo H$maU hmo gH$Vo h¡  nhbm, O‘©{H$b bmB’$ B§SrHo$Qa {H$ Om§M
H$ao  ¶{X dh bmb a§J H$m h¡, Vmo H¥$n¶m O‘©{H$b {H$Q™ ‘±JmE Am¡a
Cgo ~Xb Xo  Eogr pñW{V ‘| Q°mn Moå~a ‘| Am¡a nmZr Z Smb|  Xÿgam,
¶{X O‘©{H$b B§SrHo$Qa bmb a§J H$m Zht h¡ Vmo H¥$n¶m H$m~©Z nm°{bea Am¡a
ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ H$mo gmµ’$ H$a| Am¡a g~ KQH$m| H$mo AÀNr
Vah go ³boqµOJ H$bo³eZ Moå~a ‘| gpå‘{bV H$a Xo§  ¶{X {’$a ^r
g‘ñ¶m aho Vmo H¥$n¶m ߶mo[aQ ESdmÝgS hoënbmB©Z go g§nH©$ H$a| 
nmZr H$mo ewÕ hmoZmo ‘| {H$VZm g‘¶ bJVm h¡ ?
߶mo[aQ ESdmÝgS ‘| SmbZo dmbm nmZr H$s JwUdÎmm na ¶h {Z^©a hmoVm
h¡ Am‘Vm¡a na 9 {bQa nmZr 1.5-2 KÝQo ‘| ewÕ hmo OmVm h¡  H$m~©Z
nm{bea™ Am¡a ESdmÝgS ‘mBH«$moµ’$mB©~a ‘oe™ H$mo {Z¶{‘V gmµ’$ H$aZo
go àdmh Xa ^r gwYaVr h¡ 
AJa ‘¢ H$B© {XZm| VH$ ߶mo[aQ ESdmÝgS BñVo‘mb Z H$é± Vmo ³¶m ‘wPo
Cg‘| go nmZr {ZH$mb H$a Cgo Imbr H$a XoZm Mm{hE?
AJa ߶mo[aQ ‘| 2 {XZ go Á¶mXm éH$m hþAm nmZr h¡ Vmo nmZr H$m EH$
gmBH$b H$mo {ZH$mb X| Am¡a nmZr Ho$ Z¶o gmBH$b go Cn¶moJ àma§^ H$a|
36
Warranty Registration Card
Serial no.
Purchaser’s name
Telephone no.
Address
	  
Dealer’s name
Address
Date of purchase
______________________________
Dealer’s Signature
(with rubber stamp)
Removes 1 Crore virus in 1 Litre of water*
Note:
1.	 Please retain the bill of purchase.
2.	 Please quote the serial number, model  date of purchase in all your correspondence.
3.	 Call Pureit helpline to upate your details into our database.
37
pureit advanced warranty details
Product warranty
The Pureit advanced purifier guarantees that you will get ‘Safer Than Boiled Water’ as long as the purifier is used in the manner specified in this manual.
In addition, we cover your Pureit advanced purifier with a six-month warranty against manufacturing defects.
General
For the purpose of this warranty, the following expressions shall have the following meanings respectively:
‘The purifier’ shall mean the purifier described in the invoice.
‘The customer’ shall mean the purchaser of the purifier from the company or the company’s authorised dealer who is a party to the invoice.
‘The company’ shall mean Hindustan Unilever Limited.
‘Invoice’ shall mean the Invoice issued for the purifier by the retailer to the customer describing the purifier and indicating, inter alia, the total purchase price thereof,
the name and address of the customer.
‘User manual’ shall mean the instructions for installation, use and maintenance contained in the leaflet published by the company, and delivered to the Customer at the time of sale of the
purifier.
38
pureit advanced warranty details
This warranty is subject to the following conditions
The customer will notify the company in writing or by calling the helpline promptly of any defects noticed and give the company or its authorised agent adequate opportunity to inspect,
test and remedy them for which the customer will deposit the purifier if so required by the company, with the company’s office/service centre/authorised dealer along with the original
invoice, in the city where it was sold.
The company’s obligation under this warranty shall be limited to repairing or providing replacement of parts, found to be defective. The company or its authorised agent will be entitled to
retain any defective part replaced under the warranty.
Inspection and test report of the company’s office/service centre/authorised dealer will be final and binding under the warranty for determining defects, repairs/alterations required or
carried out, or certifying working of the purifier thereafter.
The company’s liability under this warranty shall in no event, and under no circumstances, exceed the price paid by the customer.
This warranty is confined to the first purchaser of the product only and is not transferable.
In the event of repairs of any part/s of the purifier, this warranty will thereafter continue and remain in force only for the unexpired period of the warranty. The warranty is issued at
Mumbai, and courts at Mumbai shall have exclusive jurisdiction over matters covered or flowing from this warranty.
The company’s obligation is only for effective repairs of any defective part of the purifier, and not for purifier replacement as such. Repairs or replacements will be carried out by the
company’s office/service centre/authorised dealer from whom the purifier has been purchased.
For purifiers installed beyond the municipal limits of the jurisdiction of the authorised service centre/authorised dealer, all expenses incurred in collecting the purifier/s, or parts thereof
from the company’s service center/authorised dealer, as well as expenses incurred with deputising of service personnel/technicians towards conveyance and other incidentals etc. shall be
borne by the customer.
The warranty is void if any repair work is carried out by persons other than those of the company, or its authorised dealers.
The warranty is void if the serial number is deleted from the bottom of the purifier.
This warranty is valid in India only.
Notwithstanding anything to the contrary contained in, or implied by this warranty:
The company’s liability under this warranty shall be limited only to defects in the purifier which occur under the conditions of normal operation of the purifier and it's proper and
prescribed use as per this user manual. This warranty does not cover or extend to defects which are determined by the company or its authorised agents as occurring or resulting from or
attributable to negligence, abuse, misuse, faulty care, operation or maintenance or repairs, alterations to the purifier or any part thereof by others.
The three components of the Germkill Kit™ are not covered by this warranty, and have to be separately bought by the consumer once their life is over.
Visit the Pureit website for more detailed instructions on cleaning  maintenance of your purifier
Warranty doesn’t cover any damage/other issue arising out of ingress of external/foreign material (like dust, insects, ants, other pests) in the water purifier as it is the responsibility of the
consumer to keep the area around the purifier clean and free of pests/dust.
39
Technical specifications for pureit ADVANCED
߶mo[aQ ESdmÝgS H$s VH$ZrH$s OmZH$mar
Pureit Advanced / ߶mo[aQ ESdmÝgS
Height / D§$MmB© 61 cms / 61 g|. ‘r
Width / Mm¡‹SmB© 33 cms / 33 g|. ‘r
Depth / JhamB© 36 cms / 36 g|. ‘r
Weight / dµOZ 3.7 kgs / 3.7 {H$ J«m
Total purifier volume / nyao ߶moar’$m¶a H$s j‘Vm 23 litres / 23 brQa
Water storage capacity / nmZr ^§SmaU H$s j‘Vm 9 litres / 9 brQa
Material of construction
{Z‘m©U gm‘J«r
Food safe, non-toxic, engineering plastics
ImÚ J«oS, J¡a {df¡bo A{^¶m§{ÌH$s ßbmpñQH$
Germkill Kit™ / O‘©{H$b {H$Q™
Material of construction / {Z‘m©U gm‘J«r Food safe, non-toxic, engineering plastics / ImÚ J«oS, J¡a {df¡bo A{^¶m§{ÌH$s ßbmpñQH$
Purification capacity
߶mo[a{’$Ho$eZ j‘Vm
The Germkill Kit™ has been designed to typically give 1500 litres (under standard
test conditions^) of Safer Than Boiled Water~
/ O‘©{H$b {H$Q™ H$mo bJ^J 1500 brQa
(à¶moJembo¶ narjU pñW{V^ Ho$ A§VJ©V) C~bo nmZr go µÁ¶mXm gwa{jV nmZr~
XoZo Ho$ {bE ~Zm¶m J¶m h¡.
Expiry period / OrdZ Ad{Y Two years from the date of manufacturing / {Z‘m©U {V{W go Xmo df©
Germkill performance standard
O‘©{H$b àXe©Z ‘mZH$
Meets stringent international criteria of the Environmental Protection Agency (EPA),
USA, for harmful viruses  bacteria removal
EZdm¶a‘|Qb àmoQo³eZ EO|gr (B© nr E). ¶y Eg Eo. hm{ZH$maH$ ~¡³Qo[a¶m Am¡a dmBagm| {Z‘y©bZ Ho$ H$‹So
‘mn X§Sm| na Iam CVaVm h¡
^Standard test conditions / ^ ñQ¢SS© narjU pñW{V¶m± -
•	Water temperature: 23° C / nmZr H$m Vmn‘mZ… 23° C
•	Relative Humidity: 55% to 65% / àmg§{JH$ AmЩVm… 55% go 65%
•	Water quality parameters / nmZr H$s JwUdÎmm Ho$ n¡am‘rQa
- TDS: 300+/- 10 PPM / QrSrEg… 300+/-10 nrnrEg
- PH: 7.5+/- 0.5 / nrEM… 7.5+/-0.5
- TOC:  1 PPM / QrAmogr…  1 nrnrE‘
- Turbidity:  1 NTU / Q~u{SQr…  1 EZQr¶y
~
As per Independent LabTests Pureit removes lead from input water whereas boiling cannot.
40
statement of hindustan unilever’s intellectual
property rights
Products covered under Hindustan Unilever’s
intellectual property rights
Pureit™ Microfibre Mesh™
Germkill Kit™ Activated CarbonTrap™
Germkill Action™ Germkill Processor™
Germkill Life Indicator™ Polisher™
© HUL 2010
Central
Food
Technological
Research
Institute
National
Environmental
Engineering
Research
Institute
Apollo
Hospitals,
Chennai
Institution of
Public Health
Engineers,
India
Indian Public
Health
Association
Certifications
Setting benchmarks
in water purification
Winning laurels
across the world
No.1 choice of
families Worldwide
- India
- Mexico
- Indonesia
- Brazil
- Bangladesh
Pureit is the world’s largest
selling water purifier brand#
*Representation of the US EPA torture test of 4 log virus removed from 1 ml of contaminated water.
#
Based on Unit shipment sales for 2013. Excludes pitchers and faucet mount systems sales and includes only in-home point-of-use drinking water treatment systems.
~
As per Independent LabTests Pureit removes lead from input water whereas boiling cannot.

More Related Content

Similar to Pureit Tutorials with Advanced Manual - Indian Verson

Similar to Pureit Tutorials with Advanced Manual - Indian Verson (20)

Accountancy Question Paper-Set-2
Accountancy Question Paper-Set-2Accountancy Question Paper-Set-2
Accountancy Question Paper-Set-2
 
Ncord Health Mahaonline
Ncord Health MahaonlineNcord Health Mahaonline
Ncord Health Mahaonline
 
Pawar Sarita 2023. .
Pawar Sarita 2023.                         .Pawar Sarita 2023.                         .
Pawar Sarita 2023. .
 
Aisi Akshare Diwali Ank -2009
Aisi Akshare Diwali Ank -2009Aisi Akshare Diwali Ank -2009
Aisi Akshare Diwali Ank -2009
 
Girimitra sammelan 2019 souvenir
Girimitra sammelan 2019 souvenirGirimitra sammelan 2019 souvenir
Girimitra sammelan 2019 souvenir
 
Pavitra samay 15_december_2017_to_14_january__2018
Pavitra samay 15_december_2017_to_14_january__2018Pavitra samay 15_december_2017_to_14_january__2018
Pavitra samay 15_december_2017_to_14_january__2018
 
Multimedia
MultimediaMultimedia
Multimedia
 
S 01-hindi
S 01-hindiS 01-hindi
S 01-hindi
 
April ki ek udas raaat kahani pankaj subeer
April ki ek udas raaat kahani pankaj subeerApril ki ek udas raaat kahani pankaj subeer
April ki ek udas raaat kahani pankaj subeer
 
April ki ek udas raaat kahani pankaj subeer
April ki ek udas raaat kahani pankaj subeerApril ki ek udas raaat kahani pankaj subeer
April ki ek udas raaat kahani pankaj subeer
 
Manan Lines For All
Manan Lines For AllManan Lines For All
Manan Lines For All
 
Risk Management For Manufacturing
Risk Management For ManufacturingRisk Management For Manufacturing
Risk Management For Manufacturing
 
Navsarni Bulletin - March 2014
Navsarni Bulletin - March 2014Navsarni Bulletin - March 2014
Navsarni Bulletin - March 2014
 
Matemática - Primer Ciclo - Actividades - Nivel Secundario
Matemática - Primer Ciclo - Actividades - Nivel SecundarioMatemática - Primer Ciclo - Actividades - Nivel Secundario
Matemática - Primer Ciclo - Actividades - Nivel Secundario
 
042 ashshura
042 ashshura042 ashshura
042 ashshura
 
Vetri Vazivu Geethangal
Vetri Vazivu GeethangalVetri Vazivu Geethangal
Vetri Vazivu Geethangal
 
Krutrim paus 1
Krutrim paus 1Krutrim paus 1
Krutrim paus 1
 
THE HISTORY OF MITHILA
THE HISTORY OF MITHILATHE HISTORY OF MITHILA
THE HISTORY OF MITHILA
 
20090912 CSSNite Lp7
20090912 CSSNite Lp720090912 CSSNite Lp7
20090912 CSSNite Lp7
 
maxfuel2 oil saving device
maxfuel2 oil saving devicemaxfuel2 oil saving device
maxfuel2 oil saving device
 

Recently uploaded

$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...PsychicRuben LoveSpells
 
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)Delhi Call girls
 
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girlsPooja Nehwal
 
WOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptxWOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptxpadhand000
 
Pokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy TheoryPokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy Theorydrae5
 
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)Delhi Call girls
 
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,dollysharma2066
 
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)Delhi Call girls
 
LC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdfLC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdfpastor83
 
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morcall Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morvikas rana
 
The Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by MindbrushThe Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by MindbrushShivain97
 
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)Delhi Call girls
 

Recently uploaded (15)

$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
 
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
 
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
 
WOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptxWOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptx
 
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
 
Pokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy TheoryPokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy Theory
 
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
 
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
 
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
 
LC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdfLC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdf
 
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morcall Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
 
The Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by MindbrushThe Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by Mindbrush
 
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
 
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
 

Pureit Tutorials with Advanced Manual - Indian Verson

  • 1. 1 Welcome to the Pureit Family REACH PUREIT AT www.pureitwater.com 1860-210-1000 Removes 1 Crore virus in 1 Litre of water *
  • 2.
  • 3. 1 Congratulations! Welcome to the Pureit Family! We thank you for the trust you have shown in our product and we guarantee you that our product will live up to your expectations. Pureit is trusted by millions of users around the world for providing safe drinking water for their loved ones. Our product is developed by experts and is designed to give you water that is ‘Safer Than Boiled Water’. Pureit adheres to some of the toughest standards of leading institutions both in India and abroad. If ever you need to get in touch with us for anything, please call us at 1860-210-1000. We once again thank you for buying our product and we look forward to a long and fruitful association with you. ~YmB©! ߶mo[aQ> n[adma ‘| AmnH$m ñdmJV h¡! AmnZo h‘mao CËnmX ‘| Omo é{M {XImB© h¡ CgHo$ {bE YݶdmX Am¡a h‘ Jma§Q>r XoVo h¢ {H$ h‘mao CËnmX AmnH$s AnojmAm| na Iam CVa|Jo& AnZo {à¶OZm| H$mo gwa{jV nrZo H$m nmZr CnbãY H$amZo Ho$ {bE Xþ{Z¶m ^a ‘| bmIm| Cn^moº$mAm| Zo ߶mo[aQ> na {dídmg {H$¶m h¡& h‘mao CËnmX H$mo E³gnQ>©g Zo {dH${gV {H$¶m h¡ Am¡a Bg Vah {S>OmBZ {H$¶m h¡ {Oggo dh AmnH$mo ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ Xo gHo$ & ߶mo[aQ> ^maV d {dXoe H$s à‘wI B§ñQ>rQ²>¶ye§g Ho$ H${R>Z ñQ>¢S>S>©g H$m nmbZ H$aVm h¡& {H$gr H$maU go ¶{X AmnH$mo h‘go g§nH©$ H$aZo H$s Amdí¶H$Vm hmo, Vmo H¥$n¶m h‘| 1860-210-1000 na ’$moZ H$a|& AmnZo h‘mam CËnmX IarXm CgHo$ {bE nwZ… YݶdmX Ed§ h‘ Amngo b§~m d ‘Ywa gå~ÝY ~ZmE aIZo H$s Amem aIVo h¢& Removes 1 Crore virus in 1 Litre of water* World’s largest selling purifier#
  • 4.
  • 5. 3 Pureit advantages ߶mo[aQ> ES>dmÝgS> Ho$ ’$m¶Xo ......................................................................... 4 Getting to Know Your Pureit AnZo ߶mo[aQ> ES>dmÝgS H$mo Om{ZE.................................................................. 6 How Pureit Works ߶mo[aQ> ES>dmÝgS> H¡$go H$m‘ H$aVm h¡............................................................... 8 Setting up Pureit ߶mo[aQ> ES>dmÝgS H$s ñWmnZm....................................................................... 9 Ordering the Germkill Kit™ O‘©{H$b {H$Q™ IarXZm........................................................................... 13 Cleaning & maintenance of Pureit ߶mo[aQ> ES>dmÝgS H$s g’$mB© Am¡a aI aImd.................................................... 16 Do’s & Don’ts ³¶m H$a| Am¡a ³¶m Zm H$a|.......................................................................... 28 FAQs A³ga nyN>o OmZo dmbo gdmb...................................................................... 32 Pureit Advanced Warranty Details ߶mo[aQ> ES>dmÝgS dmaÝQ>r {ddaU.................................................................. 36 Technical specifications for Pureit Advanced ߶mo[aQ> ES>dmÝgS H$s VH$ZrH$s OmZH$mar........................................................ 39 CONTENTS gyMr
  • 6. 4 pureit Advanced Advantages ߶mo[aQ> ES>dmÝgS> Ho$ ’$m¶Xo Auto Shut-Off™ Am°Q>mo eQ>-Am°µ’$™ Safer Than Boiled Water~ C~bo nmZr go µÁ¶mXm gwa{jV nmZr~ No harmful bacteria, virus & parasites H$moB© hm{ZH$maH$ ~¡³Q>o[a¶m, dmBag ¶m n¡amgmB©Q> Zht No boiling nmZr C~mbZo H$s µOéaV Zht No gas J¡g H$s µOéaV Zht No electricity {~Obr H$s µOéaV Zht No continuous tap water needed ~hVo nmZr H$s µOéaV Zht Easy maintenance AmgmZ aI aImd With double protection XþJZr gwajm Ho$ gmW New generation Microcharged Membrane technology ZB© nr‹T>r H$s ‘mBH«$moMmÁS>© ‘oå~«oZ VH$ZrH$
  • 7. 5 pureit Advanced Advantages ߶mo[aQ> ES>dmÝgS> Ho$ ’$m¶Xo Strong and durable ‘µO~yV Am¡a {Q>H$mD$ Food grade plastic ImÚ J«oS> ßbmpñQ>H$ No chlorine taste ³bmoarZ ñdmX Zht h¡ No A.M.C Eo.E‘.gr H$s µOéaV Zht No undesirable odour H$moB© XþJ©ÝY Zht No plumbing ßb§q~J H$s µOéaV Zht Natural tasting water àmH¥${VH$ ñdmX Great after sales service {~H«$s Ho$ ~mX AÀN>r godm World’s largest selling water purifier Xþ{Z¶m H$m g~go Á¶mXm {~H$Zo dmbm dmQ>a ߶moar’$m¶a
  • 8. 6 GETTINGTO KNOWYOUR pureit Advanced AnZo ߶mo[aQ> ES>dmÝgS> H$mo Om{ZE Top Lid Q°mn {bS Top Cover Q°mn H$da Top Chamber Q°mn M¡å~a Carbon Polisher™ H$m~©Z nm{bea™ Advanced Microfiber Mesh™ ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™
  • 9. 7 Germkill Life Indicator™ Cover O‘©{H$b bmB’$ B§{SHo$Qa™ H$da Tap Zb Microcharged Membrane assembly ‘mBH«$moMmµÁS© ‘oå~«Z Agoåãbr Transparent Chamber Q´§mgna|Q M¡å~a Pedestal noSoñQb Germkill Life Indicator™ O‘©{H$b bmB’$ B§{SHo$Qa™ Cleansing Collection Chamber ³b|qOJ H$bo³eZ M¡å~a Germkill Processor™ O‘©{H$b àmogoga™ Batching Chamber ~¡qMJ M¡å~a GETTINGTO KNOWYOUR pureit Advanced AnZo ߶mo[aQ ESdmÝgS H$mo Om{ZE
  • 10. 8 How Pureit Advanced Works nmo[aQ ESdmÝgS H¡$go H$m‘ H$aVm h¡ Removes harmful parasites, pesticides and chlorine, making the water clear, odorless and natural tasting. Carbon Polisher™ Purifies the water again and removes harmful parasites giving the assurance of double protection. Mic rocharged Membr ane hm{ZH$maH$ naOrdr, H$sQZmeH$ VWm ³bmoarZ H$mo {ZH$mbVm h¡ Am¡a nmZr H$mo ñdÀN, J§YhrZ ~Zm Ho$ àmH¥${VH$ ñdmX XoVm h¡ H$m~©Z nm{bea™ nmZr H$mo {’$a go ewÕ H$aVm h¡ Am¡a hm{ZH$maH$ naOrdr H$mo hQmVm h¡ VWm XþJwZr gwajm H$m AmœmgZ XoVm h¡ ‘mBH«$moMmÁS© ‘oå~«oZ Uses ‘Programmed Germkill Technology’ to target and remove harmful viruses and bacteria. hm{ZH$maH$ dm¶ag Am¡a ~o³Qo[a¶m H$mo bú¶ ~ZmH$a Xÿa H$aZo Ho$ {bE “àm¡Úmo{JH$ H$sQmUy ZmeH$ VH$ZrH$” H$m à¶moJ H$aVm h¡ O‘©{H$b àmogoga™ Removes visible dirt and precipitated metallic impurities. Advan ced Microfiber M esh™ {XImB© XoZo dmbo ‘¡b Am¡a YmVw Ho$ Cn{OV H$U H$mo {ZH$mbVm h¡ ESdm ÝgS ‘mBH«$mo’$mB~a ‘oe™ G ermkill Processor ™
  • 11. 9 setting up pureit Advanced ߶mo[aQ ESdmÝgS H$s ñWmnZm Remove the Transparent Chamber with the Pedestal and keep it aside. Discard the plastic film from it. Q´§mgna|Q Moå~a H$mo noSñQb Ho$ gmW {ZH$mb X| Am¡a Cgo AbJ aI X| D$na bJo ßbmpñQH$ {’$ë‘ H$mo ’|$H$ X| Open the box. Remove the Top Cover and keep it aside. Remove and discard the thermocol. Sã~o H$mo Imob| Q°mn H$da H$mo {ZH$mbo Am¡a ~mOy ‘| aIo W‘m}H$mob H$mo {ZH$mbH$a ’|$H$ X| 1 2 There is a bellow pump in the Top Chamber. Keep it in a safe place as you will need it later for cleaning. Q°mn M¡å~a ‘| EH$ ~obmo n§n h¡ Bgo gwa{jV ñWmZ na aI X| ³¶mo{H$ g’$mB© Ho$ g‘¶ AmnH$mo BgH$s OéaV n‹SoJr CAUTION
  • 12. 10 Remove the Cleansing Collection Chamber, Top Chamber and the Top Lid and keep it aside. Discard the thermocol from the Top Chamber. ³boqµOJ H$bo³eZ Moå~a, Q°mn Moå~a Am¡a Q°mn {bS H$mo {ZH$mb Ho$ AbJ go aI| Q°mn Moå~a Ho$ AÝXa aIo hþE W‘m}H$mob H$mo µ’|$H$ Xo 3 Wash hands thoroughly. Remove the Microcharged Membrane Assembly from tamper proof pouch kept inside the Top Chamber. hmWm| H$mo AÀNr Vah go Ymo¶| Q°mn Moå~a Ho$ AÝXa aI| W¡br go ‘mB©H«$moMmO©S ‘oå~«oZ H$mo {ZH$mb| 4 setting up pureit Advanced ߶mo[aQ ESdmÝgS H$s ñWmnZm
  • 13. 11 setting up pureit Advanced ߶mo[aQ ESdmÝgS H$s ñWmnZm Insert the Microcharged Membrane assembly at the base of the Cleansing Collection Chamber. Twist in clockwise direction to fit. ‘mB©H«$moMmO©S ‘oå~«oZ Ag|ãbr H$mo ³boqOJ H$bo³eZ Moå~a Ho$ ZrMo bJm¶| Xm§¶o Vaµ’$ ‘| Bgo ‘mo‹So {Oggo ¶h AÀNr Vah go bJ Om¶o 5 Remove paper sleeve from the Cleansing Collection Chamber. nona ñbrd H$mo ³boqµOJ H$bo³eZ Moå~a go {ZH$mb| 6 Now place the Cleansing Collection Chamber on the Transparent Chamber. ³boqµOJ H$bo³eZ Moå~a H$mo Q´m§gna|Q Moå~a Ho$ D$na aI| 7 After fitting the Microcharged Membrane assembly to the Cleansing Collection Chamber, do not rest the assembly on a flat surface. ‘mB©H«$moMmO©S ‘oå~«oZ Agoå~br H$mo ³boqµOJ H$bo³eZ Moå~a ‘| AÀNr Vah go bJmZo Ho$ ~mX Bgo g‘mZ gVh na Zm aIo Please remove the paper sleeve from the Cleansing Collection Chamber before use. ߶mo[aQ H$m Cn¶moJ H$aZo go nohbo H¥$n¶m nona ñbrd H$mo ³boqµOJ H$bo³eZ Moå~a go {ZH$mb| CAUTION
  • 14. 12 setting up pureit Advanced ߶mo[aQ ESdmÝgS H$s ñWmnZm Place the Top Chamber on the Cleansing Collection Chamber and the Top Cover on the Top Chamber. Q°mn Moå~a H$mo ³boqµOJ H$bo³eZ Moå~a Ho$ D$na aI| Am¡a Q°mn H$da H$mo Q°mn Moå~a Ho$ D$na aI| Pour in water till the top of the Top Chamber and drain out all the water that collects in the Transparent Chamber. Place the lid on the Top Cover. Pureit Advanced is now ready for use from second cycle onwards. Q°mn Moå~a Ho$ D$na VH$ nmZr ^ao Am¡a Q´mgna|Q Moå~a ‘| BH$Q²Rm hþE nmZr H$mo {ZH$mb X| Q°mn H$da H$mo {bS go T§H$ X| ߶mo[aQ ESdmÝgS Xÿgao gmBH$b go Cn¶moJ H$aZo Ho$ {bE V¡¶ma h¡ 8 9 Please note that the first cycle will not give full 9L of water in the Transparent Chamber since some water gets stored in the Cleansing Collection Chamber and the Top Chamber. H¥$n¶m OmZ b| {H$ nhbo gmBH$b go Ûmam nyam 9 brQa nmZr Q´m§gna|Q Moå~a ‘| Zhr§ {‘boJm ³¶m|{H$ Wmo‹Sm gm nmZr ³boqµOJ H$bo³eZ Moå~a Am¡a Q°mn Moå~a ‘| O‘m hmoVm h¡
  • 15. 13 ORDERINGTHE GERMKILL KIT™ (GKK) O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZm Once the Germkill Life Indicator™ turns fully red, please replace the Germkill Kit™ (GKK) immediately. As an additional measure of safety, Auto Shut-Off™ mechanism of the Pureit Advanced, shuts off the supply of purified water which ensures that no member of your family accidentally drinks unsafe water. O‘©{H$b bmB’$ B§{SHo$Qa™ nyar Vah bmb hmo OmZo na H¥$n¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$) H$mo Vwa§V ~Xb X| gwajm Ho$ A{V[aº$ ^amogo Ho$ Vm¡a na ߶mo[aQ H$m AmYw{ZH$ Am°Qmo eQ Am°’$™ V§Ì ߶moar’$m¶ {H$¶o hþE nmZr H$s gßbmB© ~§X H$a XoVm h¡ {Oggo gw[ZpíMV hmoVm h¡ H$s AmnHo$ n[adma H$m H$moB© gXñ¶ JbVr go Agwa{jV nmZr Z nr gHo$ There is an Auto Shut-Off™ overflow port provided on the Germkill Life Indicator™ cover. When the Germkill Life Indicator™ is red, you might observe overflow from this port. Please replace the Germkill Kit™(GKK). Do not pour any more water in theTop Chamber to avoid further spillage. O‘©{H$b bmB’$ B§{SHo$Qa™ H$da na EH$ Am°Qmo eQ-Am°’$ Ûma àXmZ {H$¶m J¶m h¡ O~ O‘©{H$b bmB’$ B§{SHo$Qa™ bmb a§J H$m hmo OmVm h¢, V~ Amn Bg Ûma go A{Vàdmh XoI gH$Vo h¢ H¥$n¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$) H$mo ~Xb X| A{YH$ ZwH$gmZ go ~MZo Ho$ {bE Q°mn Moå~a ‘| A{YH$ nmZr Z Smbo§ When Indicator shows white or partially red, the Germkill Kit™ (GKK) is working and it’s safe to use. O~ B§{SHo$Qa Xem© ahm hmo gµ’o$X ¶m hëH$m gm bmb, BgH$m ‘Vb~ O‘©{H$b {H$Q™ (Or Ho$ Ho$) H$m‘ H$a ahm h¡ Am¡a Cn¶moJ Ho$ [bE gwa{jV h¡ When Indicator shows mostly red, the Germkill Kit™ (GKK) is nearing its end of life and its time to buy a new Germkill Kit™ (GKK). O~ B§{SHo$Qa Xem© ahm hmo A{YH$Va bmb, BgH$m ‘Vb~ O‘©{H$b {H$Q™ (Or Ho$ Ho$) IË‘ hmoZo dmbm h¡ Am¡a Z¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZo H$m g‘¶ hmo J¶m h¡ When Indicator shows fully red, the Germkill Kit™ (GKK) has exhausted and it is time to replace it. O~ B§{SHo$Qa Xem© ahm hmo nyar Vah bmb, BgH$m ‘Vb~ O‘©{H$b {H$Q™ (Or Ho$ Ho$) H$s j‘Vm IË‘ hmo J¶r h¡ Am¡a O‘©{H$b {H$Q™ (Or Ho$ Ho$) ~XbZo H$m g‘¶ hmo J¶m h¡ Safe to use Cn¶moJ Ho$ [bE gwa{jV Time to buy a new Germkill Kit™ (GKK) Z¶m O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZo H$m g‘¶ hmo J¶m h¡ Time to replace ~XbZo H$m g‘¶ hmo J¶m h¡ With advanced Auto Shut-OffTM CAUTION
  • 16. 14 You can buy a Germkill Kit™ (GKK) in any of the following ways Amn {ZåZ{b{IV VarH$m| go Z¶m O‘©{H$b {H$QTM (Or Ho$ Ho$) IarX gH$Vo h¢ Visiting a shop XþH$mZ go Calling up Pureit helpline ߶mo[aQ hoënbmBZ na µ’$moZ H$ao Ordering on the website do~gmBQ na AmS©a H$a Ho$ 1860-210-1000 www.pureitwater.com ORDERINGTHE GERMKILL KIT™ (GKK) O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZm
  • 17. 15 There are multiple Pureit Germkill Kit™(GKK) available. Please buy the one that is recommended for your Pureit Advanced model. ߶mo[aQ Ho$ AZoH$ àH$ma Ho$ O‘©{H$b {H$Q™ (Or Ho$ Ho$) CnbãY h¢. H¥$n¶m AmnHo$ ߶mo[aQ ‘m°Sb ‘| {’$Q hmoZo dmbr O‘©{H$b {H$Q™ (Or Ho$ Ho$) hr IarX| Microcharged Membrane ‘mB©H«$moMmO©S ‘oå~«Z Germkill Processor™ O‘©{H$b àmogoga™ Carbon Polisher™ H$m~©Z nm{bea™ The Germkill Kit™ (GKK) consists of 3 parts O‘©{H$b {H$Q™ (Or Ho$ Ho$) ‘| 3 nwO} hmoVo h¢ ORDERINGTHE GERMKILL KIT™ (GKK) O‘©{H$b {H$Q™ (Or Ho$ Ho$) IarXZm CAUTION
  • 18. 16 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd Remove Top Lid and clean it with tap water. Leave it to drip dry. Q°mn {bS H$mo {ZH$mbo§ Am¡a Cgo Zb Ho$ nmZr go gmµ’$ H$a| AÀNr Vah gyIZo Ho$ {bE aI X| 1 2 Remove Top Cover and clean it with tap water. Leave it to drip dry. Q°mn H$da H$mo {ZH$mb| Am¡a Cgo Zb Ho$ nmZr go gmµ’$ H$a| AÀNr Vah gyIZo Ho$ {bE aI X|
  • 19. 17 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd Slightly pull the Germkill Life Indicator™ Cover upwards and remove it from the purifier. O‘©{H$b bmB©µ’$ BpÝSHo$Qa™ H$da H$mo hëHo$ go Cna H$s Vaµ’$ ItMo Am¡a Cgo ߶moar’$m¶a go {ZH$mb| 43 Do not clean the hole in the Top Chamber with sharp objects. Q°mn Moå~a Ho$ NoXm| H$mo ZwH$sbo dñVw go gmµ’$ Z H$a| Rinse the Top Chamber with clean water and leave it to ‘drip dry’ in a clean place. Q°mn Moå~a H$mo AÀNo gmµ’$ nmZr go Ymo¶| Am¡a gwIZo Ho$ {bE {H$gr gmµ’$ OJh na aI| CAUTION
  • 20. 18 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd Empty the water from the Cleansing Collection Chamber. ³boqµOJ H$bo³eZ Moå~a ‘| go nmZr Imbr H$a X| Rotate the Germkill Processor™ in the anti-clockwise direction to remove and keep it in a safe place. O‘©{H$b àmogoga™ H$mo ~m§¶r Vaµ’$ Kw‘mH$a {ZH$mb| Am¡a {H$gr gwa{jV OJh na aI| 65 Wash hands thoroughly. Rotate the Microcharged Membrane assembly in anti-clockwise direction to remove. Keep it aside in a clean place. hmWm| H$mo AÀNr Vah go Ymo¶| ‘mBH«$moMmO©S ‘oå~«oZ Agoå~br H$mo ~m§¶r Vaµ’$ ‘| Kw‘mH$a {ZH$mb| Cgo AbJ go {H$gr gmµ’$ OJh na aI| 7
  • 21. 19 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 8 Do not remove the Microcharged Membrane assembly without emptying water from the Cleansing Collection Chamber. ³boqµOJ H$bo³eZ Moå~a go nmZr Imbr {H$E {~Zm ‘mBH«$moMmÁS© ‘oå~«oZ Ag|ãbr H$mo Z {ZH$mb| Rotate the Advanced Microfiber Mesh™ in the anti-clockwise direction to remove.The Carbon Polisher™ will come out along with it. ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ H$mo ~m§¶o Vaµ’$ Kw‘m¶| H$m~©Z nm{bea™ CgHo$ gmW ~mha Am OmEJm Rotate the Carbon Polisher™ in the anti-clockwise direction to remove. H$m~©Z nm{bea™ H$mo ~m§¶o Vaµ’$ ‘| Kw‘mH$a {ZH$mb| 9 CAUTION
  • 22. 20 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd Wash the Advanced Microfiber MeshTM under a jet of water. ESdmÝgS ‘mBH«$mo’$mB~a ‘oeTM H$mo VoµO nmZr Ho$ ZrMo YmoE± 10 Fill Pureit water in the Bellow Pump. ~obmo nån ‘| ߶mo[aQ nmZr ^a| 11 12 Insert the Bellow Pump into the nozzle at the bottom of the Carbon Polisher™, the area opposite to side with handles given. ~obmo nån H$mo H$m~©Z nm{bea™ Ho$ ZrMo Zbr ‘| bJmE± ¶o hoÝSb dmbr OJh Ho$ CëQo dmbr OJh h¡
  • 23. 21 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 13 14 Clean the Cleansing Collection Chamber with clean water and leave to drip dry. ³boqµOJ H$bog³eZ Moå~a H$mo gmµ’$ nmZr go YmoE± Am¡a AÀNr Vah go gyIZo Ho$ {bE aI X| Close the mouth of the carbon block with one hand and squeeze the Bellow Pump with the other hand to force the water through the carbon block. You can see dirt coming out of the carbon block. Repeat procedure 5-6 times. H$m~©Z ãbm°H$ Ho$ ‘w§h H$mo EH$ hmW go ~§X H$ao Am¡a ~obmo nån H$mo Xþgao hmW go X~m¶| {Oggo {H$ H$m~©Z ãbm°H$ ‘| nmZr H$m X~md ~‹To Amn XoI|Jo {H$ H$m~©Z ~bm°H$ go ‘¡b ~hma {ZH$mb ahm h¡ Bg à{H«$¶m H$mo 5-6 ~ma XmohamE± You may observe some amount of water coming back through the Below Pump which can be pushed into the Carbon Polisher™ again. Please clean the Carbon Polisher™ with the Bellow Pump multiple times for best results. Amn XoI|Jo H$s Wmo‹Sr ‘mÌ ‘| nmZr ~obmo nån go ~mha Am ahm h¡ {Ogo nwZ… H$m~©Z nm{bea™ ‘| YHo$bm Om gH$Vm h¡ H$m~©Z nm{bea™ H$mo H$B© ~ma ~obmo nån go Ymo b| {Oggo AÀNm n[aUm‘ {‘bo CAUTION
  • 24. 22 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 16 Replace the Advanced Microfiber MeshTM Assembly in the Cleansing Collection Chamber by turning it clockwise. Ensure tightness. ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ Agoå~br H$mo ³boqµOJ H$bo³eZ Moå~a ‘| Smb| Am¡a Cgo Xm§¶o Vaµ’$ Kw‘m¶| AmeñdV H$a| {H$ dmo g»V hmo§ Wash the Transparent Chamber with clean Pureit water and ‘drip dry’. Q´m§gna|Q Moå~a H$mo ߶mo[aQ nmZr go AÀNr Vah go gm’$ H$a| Am¡a gyIZo Ho$ {bE Nmo‹So 17 Replace the Carbon Polisher™ in the Advanced Microfiber MeshTM Assembly by turning it clockwise. Ensure tightness. ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ ‘| H$m~©Z nm{bea™ H$mo Smb| Am¡a Cgo Xm§¶o Vaµ’$ ‘| Kw‘m¶| AmeñdV H$a| {H$ dmo g»V hm| 15
  • 25. 23 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 18 Fill Pureit water in the Bellow Pump. Insert the Bellow Pump into the nozzle provided at the bottom of the Microcharged Membrane assembly. ~obmo nån ‘| ߶mo[aQ H$m nmZr ^a| Cg ~obmo nån H$mo ESdmÝgS ‘mBH«$moMmÁS© Agoå~br Ho$ Vb no Xr JB© Zbr ‘| Kwgm¶| In case your water quality is very bad and the flow rate does not improve on cleansing the Advanced Microfiber Mesh™ and the Carbon Polisher™ you need to clean the Microcharged Membrane as shown above. AJa nmZr ~hþV Á¶mXm Iam~ hmo Am¡a ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ H$m~©Z nm{bea™ H$s gµ’$mB© Ho$ ~mX ^r nmZr H$m ~hmd VoµO Zm hmo Vmo {’$a ‘mBH«$moMmÁS© ‘oå~«oZ H$mo D$na {XIm¶o J¶o VarHo$ go gmµ’$ H$a| Now hold the Microcharged Membrane base and squeeze the Bellow Pump to force water out of the Microcharged Membrane assembly. You can see dirt coming out of the membrane. Repeat procedure 5-6 times. A~ ‘mBH«$moMmÁS© ‘oå~«oZ Ho$ Vb H$mo nH$S| Am¡a ~obmo nån H$mo X~m¶|, Vm{H$ nmZr nyar VoµOr go ‘mBH«$moMmÁS© ‘oå~«oZ Agoå~br go ~mha {ZH$b| Amn ‘oå~«oZ go {ZH$bVr hþB© J§XJr H$mo XoI gH$Vo h¢ Bg H$m¶©{dÜmr H$mo 5-6 ~ma Xmoham¶| 19 While cleaning the Microcharged Membrane, please ensure your hands are germ free. ‘mBH«$moMmÁS© ‘oå~«oZ gmµ’$ H$aVo dº$ ܶmZ aI| {H$ AmnHo$ hmW H$sQmUw ‘wº$ hm| CAUTION
  • 26. 24 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 21 Replace Cleansing Collection Chamber on the Transparent Chamber. Q´m§gna|Q Moå~a Ho$ D$na ³boqµOJ H$bo³eZ Moå~a H$mo aI| 20 Insert the Microcharged Membrane assembly at the base of the Cleansing Collection Chamber and turn clockwise to fit. Ensure tightness. ‘mBH«$moMmÁS© ‘oå~«oZ Ag|ãbr H$mo ³boqµOJ H$bo³eZ Moå~a Ho$ ZrMo Xm§¶o Vaµ’$ ‘| Kw‘mH$a Smb| AmídñV H$a| H$s dh g»V hmo
  • 27. 25 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 22 Insert the Germkill Processor™ and turn in clockwise direction to fit. Ensure tightness. O‘©{H$b àmogoga™ H$mo Kwgm X| Am¡a Cgo Xm§¶o Vaµ’$ ‘| Kw‘mH$a bJm X| AmœñV hmo {H$ AÀNr Vah go bJ J¶m hmo 23 Place the Germkill Life Indicator™ Cover in the grooves provided on the Cleansing Collection Chamber and push it downwards to fit. O‘©{H$b bmBµ’$ BpÝSHo$Qa™ H$da H$mo ³boqµOJ H$bo³eZ Moå~a na ~Zm¶o J¶o Im§Mo ‘| aI| Am¡a Cgo ZrMo {IgH$m Ho$ AÀNr Vah bJmE±
  • 28. 26 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd 25 Replace the Top Cover and Top Lid on the Top Chamber. Q°mn Moå~a Ho$ D$na Q°mn H$da Am¡a Q°mn {bS H$mo aI| 24 Replace the Top Chamber on the Cleansing Collection Chamber. ³boqµOJ H$bo³eZ Moå~a Ho$ D$na Q°mn Moå~a H$mo aI|
  • 29. 27 Cleaning maintenance of Pureit Advanced ߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd Clean the mouth of the tap with dilute disinfectant like bleach/hypochlorite (50 ppm available chlorine). Pour in water till the top of the Top Chamber and drain out all the water that collects in the Transparent Chamber. Refill the Top Chamber. Pureit Advanced is now ready for use from second cycle onwards. ãbrM/hmBnmo³bmoamBS (50 nrnrE‘ CnbãY ³bmoarZ) O¡go H$sQmUwZmeH$ Ho$ Cn¶moJ go Zb Ho$ Ûma H$mo gm’$ H$a| Q°mn Moå~a H$mo nmZr go ^a| Am¡a Q´m§gna|Q Moå~a ‘| O‘m hþE nmZr H$mo µ’|$H$ X| Q°mn Moå~a ‘| {’$a go nmZr ^a X| ߶mo[aQ ESdmÝgS A~ BñVo‘mb Ho$ {bE V¡¶ma h¡ 26
  • 30. 28 dos don’ts Pureit Advanced has been specially designed to give you water that is ‘SaferThan Boiled Water’ as long as the Pureit Advanced system is used in the way as prescribed in this manual. Listed below are the things that you must take care of:    DO’s    DON’Ts Clean the Top Lid, the Top Chamber, the Cleansing Collection Chamber and the tap regularly Clean with water and then leave the components to ‘drip dry’ Clean the tap with a mild hypochlorite solution If necessary, use a plastic brush to aid cleaning Remove the Germkill Processor™ while cleaning and keep upright in a separate dry place Empty the water from the Cleansing Collection Chamber before removing the Microcharged Membrane assembly Remove the Germkill Processor™ before emptying out the water from the Cleansing Collection Chamber The Pureit guarantee of getting water that is ‘Safer Than Boiled Water’ applies only if you ensure that the Transparent Chamber of the purifier and the tap are hygienically kept, and that germs are not introduced due to contact with hands, drying with a cloth, wash or any other means You should only store water in Pureit Advanced purifier and not use other bottles and containers, to avoid re-contamination of the water Always use all three components of the Pureit Advanced Germkill Kit™ together You should ensure that the area around and beneath the purifier is kept clean at all times Keep all components of the Pureit Advanced Germkill Kit™ out of reach of children at all times Do not clean with soap or detergent, or any abrasive cleaners or tools like wire Mesh Do not twist the Advanced Microfibre Mesh™ while cleaning. The Advanced Microfiber Mesh™ might change its color over a period of time. This does not affect the performance of the Advanced Microfiber Mesh™ Do not use any soap or detergent. Ensure that you don’t inadvertently introduce germs into the Transparent Chamber or the tap e.g. through your hands or by using a drying cloth. Always use purified Pureit Advanced water for doing the last rinse of the Transparent Chamber, and then let it drip-dry Do not normally wash the Cleansing-Collection Chamber Don’t pour boiling or hot water (more than 50˚C) into, or on the Pureit Advanced system. Similarly don’t pour freezing cold water (less than 10˚C) into, or on the Pureit Advanced system Do not pour hot water directly from an overhead tank or any other source in your Pureit Advanced as hot water uses up the Germkill Kit™ faster than normal. If required, allow the water to cool to room temperature before pouring it in the Top Chamber. For the same reason do not keep your Pureit Advanced in hot surroundings like direct sunlight, near a stove or near a fridge Never buy the Pureit Advanced system, or a Pureit Advanced Germkill Kit™ from an unauthorized source.You can visit a store near you to buy a Germkill Kit™ or call us at the Pureit helpline, and we will deliver a new Germkill Kit™ to you at your home for a minimal delivery charge Don’t in any way try to open the three Pureit Advanced Germkill Kit™ components Never use the system once the Pureit Advanced Germkill Life Indicator™ shows a full red colour in the window, with no white colour visible Don’t expose any of the components to fire
  • 31. 29 dos don’ts Pureit Advanced has been specially designed to give you water that is ‘SaferThan Boiled Water’ as long as the Pureit Advanced system is used in the way as prescribed in this manual. Listed below are the things that you must take care of:    DO’s    DON’Ts Ensure that the purifier is placed on a flat surface at all times, and never tilt the Transparent Chamber to take out water If you ever want to shift the purifier, do so only after both the Top Chamber and Cleansing Collection Chamber are empty. Otherwise the purifier may leak, and the purification process may get affected Always rely only on the red Indicator to replace the Germkill Kit™. The Auto Shut-Off™ is only an additional assurance of safety – in some cases, the input water quality may prevent it from functioning Freshly purified water should be used for drinking Output water may continue to have flora which are harmless and pose no health hazard to normal healthy adults and children Always clean the Pureit Advanced system only as described in the section on cleaning Don’t drop any of the components, or the purifier as a whole from a height. This may cause the components to fracture or break, and the guarantee of getting water ‘Safer Than Boiled Water’ will no longer be valid Don’t put any chemical fluids in the Pureit Advanced system. This is meant strictly for drinking water only If the Transparent Chamber is full, please do not fill water in the Top Chamber, otherwise water will overflow from the Transparent Chamber Do not try to open the Germkill Processor™ Do not pour water in purifier after Germkill Life Indicator™ turns fully red. This will prevent water overflowing due to Auto Shut-Off™. This ensures no one is accidentally hurt by slipping on the water. Also, no household item kept near purifier would get damaged by leaked water Do not use the Germkill Kit™ after expiry – which is post two years from the date of packing Do not keep the Pureit Advanced purifier in direct sunlight as it may trigger growth of algae if input water is significantly contaminated Do not use water not intended for drinking in Pureit Advanced system e.g., from abandoned or abused water bodies or water sources in which human, animal or industrial wastes are disposed, or water that is excessively acidic or alkaline Water stored for more than two days should not be consumed Do not remove the Batching Chamber from the Cleansing Collection Chamber. If it gets removed accidentally, then replace the parts in proper location, as was assembled initially for consistent performance Do not meddle with the Microcharged Membrane else it will get damaged and you might get unsafe water Don’t drink water from the purifier if any one of the Germkill Kit™ components is not fitted Do not allow any foreign or unexpected material (like dust, ants, insects, other pests) to enter into the storage tank. The purified water in the storage tank may deteriorate in the process.
  • 32. 30 ³¶m H$a| Am¡a ³¶m Zht ߶mo[aQ H$mo Bg àH$ma {SOmB©Z {H$¶m J¶m h¢ H$s O~ VH$ Amn CgH$m à¶moJ Bg nwpñVH$m Ho$ AZwgma H$a|Jo V~ VH$ Amn H$mo ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bVm ahoJm {ZåZ{b{IV MrOm| na ܶmZ X|    ³¶m H$a|    ³¶m Z H$a| Q°mn {bS, Q°mn Moå~a, ³bo{µOJ H$bo³eZ Moå~a Am¡a Q¡n {Z¶{‘V én™ go gmµ’$ H$a| nmZr go gmµ’$ H$ao Am¡a {’$a nwOm} H$mo AÀNr Vah go gyIZo Ho$ {bE Nmo‹S Xo Q¡n H$mo hëH$m hmBnmo³bmoamBQ gmoë¶yeZ go gmµ’$ H$a| µOéaV n‹SZo na g’$mB© Ho$ {bE EH$ ßbmpñQH$ ~«e H$m Cn¶moJ H$a| g’$mB© Ho$ Xm¡amZ O‘©{H$b àmogoga™ àH$aU H$mo hQm X| Am¡a EH$ AbJ gyIr OJh na grYm aI| ‘mBH$moMmÁS© ‘oå~«oZ Ag|ãbr H$mo hQmZo go nhbo ³boqµOJ H$bo³eZ Moå~a go nmZr {ZH$mb X| ³boqµOJ H$bo³eZ Moå~a ‘| go nmZr Imbr H$aZo go nhbo, O‘©{H$b àmogoga™ {ZH$mb| ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bZo H$s J°maÝQr Ho$db V~ bmJy hmoJr AJa Amn gw{ZpíMV H$aVo h¢ {H$ ߶w[a’$m¶a H$m Q´m§gna|Q M|å~a VWm Zb gm’$-gwWao aI| JE h¢, VWm hmW, H$n‹So go gwImZo, YmoZo ¶m Aݶ {H$gr ^r VarHo$ go {H$QmUwAm| Ho$ gånH©$ ‘| Z Am¶m hmo AmnH$mo Ho$db ߶mo[aQ ESdmÝgS ߶w[aµ’$¶a ‘| hr nmZr g§J«{hV H$aZm Mm{hE Am¡a nmZr H$mo nwZ… àXÿ{fV hmoZo go ~MmZo Ho$ {bE Aݶ ~moVb Am¡a ~V©Z H$m Cn¶moJ Zht H$aZm Mm{hE ߶mo[aQ ESdmÝgS O‘©{H$b {H$Q™ Ho$ g^r VrZ nwO} EH$gmW BñVo‘mb H$a| gw{ZpíMV H$a| H$s ߶w[a’$m¶a Ho$ BX©-{JX© H$m joÌ gm’$ h¡ ߶mo[aQ ESdmÝgS O‘©{H$b {H$Q™ Ho$ g^r nwO} h‘oem ~ƒm| {H$ nhþ§M go Xÿa aI| gw{ZpíMV H$a| H$s AmnH$m ߶w[a’$m¶a h‘oem g‘Vb aho, VWm nmZr {ZH$mbZo Ho$ {bE Q´m§gna|Q Moå~a H$mo Z PwH$mE§ AJa Amn ߶w[a’$m¶a H$mo Xÿgar OJh aIZm MmhVo h¢ Vmo ¶o gw{ZpíMV H$a b| H$s Q°mn Moå~a VWm ³boqµOJ H$bo³eZ Moå~a XmoZm| hr Imbr hmo AݶWm ߶w[a’$m¶a go [agmd hmo gH$Vm h¡, VWm nw[a{’$Ho$eZ H$s à{H«$¶m ~{YV hmo gH$Vr h¡ gm~wZ ¶m {SQO}Q AWdm H$moB© AnKf©H$ g’$mB© CnH$aU O¡go Vma H$s Ombr go gmµ’$ Z H$a| g’$mB© H$aVo dµ³V ESdmÝgS ‘mBH«$mo ’$mB~a ‘oe™ H$mo Z ‘mo‹So g‘¶ OmVo ESdmÝgS ‘mBH«$mo’$moB~a ‘oe H$m a§J ~Xb gH$Vm h¡ Bggo ESdmÝgS ‘mBH«$mo’$mB~a ‘oe H$m H$m¶©àXe©Z à^m{dV Zhr hmoVm h¡ {H$gr ^r gm~wZ ¶m {SQaOÝQ H$m BñVo‘mb Z H$a| gw{ZpíMV H$a b| H$s Q´m§gna|Q Moå~a ¶m Zb ‘o§ AÝOmZo ‘| ^r {H$QmUw àdoe Z H$a| CXm…- AmnHo$ hmW ¶m gwImZo dmbo H$n‹So go Q´m§gna|Q Moå~a H$mo AmIar ~ma YmoZo Ho$ {bE h‘oem ߶w[a’$mB©S ߶mo[aQ ESdmÝgS nmZr H$m hr BñVo‘mb H$a|, Am¡a {’$a go gyIZo Ho$ {bE aIo ³b|qOJ H$bo³eZ Moå~a H$mo Am‘ Vm¡a na gm’$ Z H$a| ߶mo[aQ ESdmÝgS {gñQ‘ ‘|, ¶m Cg na C~bVm hþAm ¶m Ja‘ nmZr (500 C A{YH$ Vmn‘mZ) Z Smb| gmW hr ߶mo[aQ ESdmÝgS {gñQ‘ ‘|, ¶m CgHo$ Cna O‘m XoZo dmbm R§Sm nmZr (100 C H$‘) Z Smb| AmnHo$ ߶mo[aQ ESdmÝgS ‘| {H$gr AmodahoS Q§H$s ¶m Aݶ {H$gr ómoV go grYm Ja‘ nmZr Z Smb| ³¶mo{H$ Ja‘ nmZr O‘©{H$b {H$Q™ H$s InV gm‘mݶ go A{YH$ J{V go H$aVm h¡ Amdí¶H$ hmo Vmo nmZr H$mo Q°mn Moå~a ‘o SmbZo go nhbo Cgo gm‘mݶ Vmn‘mZ VH$ AmZo X| Bgr H$maU go AmnHo$ ߶mo[aQ ESdmÝgS H$mo grYo gyaO H$s amoeZr ‘|, ñQmod Ho$ ¶m {’«$O Ho$ nmg Z aIo H$^r ^r {H$gr AZm{YH¥$V ómoV go ߶mo[aQ ESdmÝgS {gñQ‘, ¶m ߶moaBQ O‘©{H$b {H$Q™ Z IarXo§ Amn AmnHo$ H$ar~r ñQmoa go O‘©{H$b {H$Q™ IarX gH$Vo h¡ ¶m ߶mo[aQ hoënbmB©Z go gånH©$ H$a| Am¡a h‘ Zm‘‘mÌ {Sbrdar ewëH$ na EH$ Z¶m O‘©{H$b {H$Q™ AmnHo$ Ka nhþ±Mm X|Jo ߶mo[aQ ESdmÝg‹S O‘©{H$b {H$Q™ Ho$ VrZ nwOm} H$mo {H$gr ^r VarHo$ go ImobZo H$s H$mo{ee Z H$a| ߶mo[aQ O‘©{H$b ESdmÝgS bmB’$ B§{SHo$Qa™ nyar Vah go bmb {XI ahm hmo, Am¡a g’o$X a§J {~ëHw$b {XImB© Z Xo ahm hmo V~ Bg {gñQ‘ H$m H$VB© BñVo‘mb Z H$a|
  • 33. 31 ³¶m H$a| Am¡a ³¶m Zht ߶mo[aQ H$mo Bg àH$ma {SOmB©Z {H$¶m J¶m h¢ H$s O~ VH$ Amn CgH$m à¶moJ Bg nwpñVH$m Ho$ AZwgma H$a|Jo V~ VH$ Amn H$mo ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bVm ahoJm {ZåZ{b{IV MrOm| na ܶmZ X|    ³¶m H$a|    ³¶m Z H$a| O‘©{H$b {H$Q™ ~XbZo Ho$ {bE h‘oem Ho$db bmb BpÝSHo$Qa na hr ^amogm aI| Am°Qmo eQ-Am°’$™ Ho$db gwajm H$m EH$ A{Varº$ ^amogm h¡ - Hw$N ‘m‘bm| ‘|, AmZodmbo nmZr H$s JwUdÎmm CgHo$ H$m¶© ‘| éH$mdQ bm gH$Vr h¡ nrZo Ho$ {bE VmOm ewÕ {H$¶m J¶m nmZr hr Cn¶moJ H$aZm Mm{hE V¡¶ma nmZr ‘| âbmoam hmo gH$Vo h¡ Omo ZwH$gmZH$mar Zht Am¡a Omo gm‘mݶ ñdmñ϶ dmbo d¶ñH$m| d ~mbH$m| Ho$ ñdmñ϶ Ho$ {bE {H$gr àH$ma H$m IVam Zht hmoVo h¢ ߶mo[aQ ESdmÝgS {gñQ‘ H$mo Ho$db g’$mB© Ho$ go³eZ ‘| {H$E JE dU©Z Ho$ AZwgma hr gm’$ H$a| gmao nwOm} H$mo AmJ go Xÿa aI| H$moB© ^r nwOm©, ¶m ߶w[a’$m¶a H$mo D±$MmB© go Z {JamE± Bggo nwO} ’«°$³Ma hmo gH$Vo h¢ ¶m QyQ gH$Vo h¢, Am¡a ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bZo H$s J°maÝQr AmJo d¡Y Zhr ahoJr ߶mo[aQ ESdmÝgS {gñQ‘ ‘| H$moB© ^r Ho${‘H$b Z Smb| ¶h Ho$db nrZo Ho$ nmZr Ho$ {bE hr h¡ AJa Q´m§gna|Q Moå~a ^a J¶m hmo, Vmo H¥$n¶m Qm°n Moå~a ‘| nmZr Z ^a| AݶWm nmZr Q´m§gna|Q Moå~a go ~mha ~hZo bJoJm O‘©{H$b àmogoga™ H$mo ImobZo H$m à¶mg Z H$a| O‘©{H$b bmB’$ B§{SHo$Qa™ H$m a§J bmb hmo OmZo Ho$ ~mX ߶w[a’$m¶a ‘| nmZr Z Smb| Bggo Am°Qmo eQ-Am°’$™ g{H«$¶ hmo OmZo go nmZr Amodaâbmo Zhr hmoJm Am¡a nmZr na go {H$gr Ho$ {’$gbZo H$s ¶m ߶moar’$m¶a Ho$ Amg nmg aIo {H$gr gm‘mZ Ho$ ˜am~ hmoZo H$s g§^mdZm Zht ahoJr O‘©{H$b {H$Q™ H$s OrdZ Ad{Y IË‘ hmoZo Ho$ ~mX CgH$m BñVo‘mb Z H$a| - n¡qH$J Ho$ níMmV Xmo gmb VH$ ¶h Ad{Y hmoVr h¡ ߶mo[aQ ESdmÝgS ߶w[a’$m¶a H$mo grYo gyaO H$s amoeZr ‘| Z aI| nmZr A{YH$ Xÿ{fV hmoZo H$s pñWVr ‘| Bg‘| e¡dmb H$m {dH$mg hmo gH$Vm h¡ Omo nmZr nrZo Ho$ {bE Z hmo Cgo ߶mo[aQ ESdmÝgS {gñQ‘ ‘| Z Smbo CXm. A˶{YH$ Amåbr¶ ¶m jmar¶ nmZr ¶m BñVo‘mb ‘| Z AmZo dmbm ¶m Iam~ Obme¶ ¶m ObómoV H$m Eogm nmZr {OZ‘o ‘Zwî¶, àmUr ¶m H$maImZm| H$m H$Mam Smbm OmVm hmo Xmo {XZm| go A{YH$ Ad{Y H$m g§J«{hV Ob Cn¶moJ ‘| Zht b| ~°qMJ Moå~a H$mo ³boqµOJ H$bo³eZ Moå~a go Z hQm¶o AJa dh hQ Om¶o Vmo Cgo AnZr OJh no RrH$ go bJm Xo, O¡go dmo nhbo bJm hþAm Wm ‘mBH«$moMmÁS© ‘oå~«oZ go Z CbPo, Zht Vmo dh j{VJ«ñV hmo Om¶oJm Am¡a AmnH$mo nrZo Ho$ {bE Agwa{jV nmZr {‘b gH$Vm h¡ O‘©{H$b {H$Q™ H$m H$moB© nwOm© bJm¶m Z hmo Eogr pñWVr ‘| ߶w[a’$m¶a go nmZr Z {nE§ Q´m§gna|Q M¢~a ‘| {H$gr ^r {dXoer ¶m Aà˶m{eV gm‘J«r (Yyb, Mt{Q¶m|, H$s‹So, Aݶ Vah Ho$ H$sQ) H$mo àdoe H$aZo Z X| Bg à{H«$¶m go Q´m§gna|Q M¢~a H$m ߶moarµ’$mBS nmZr Iam~ hmo gH$Vm h¡
  • 34. 32 FAQs There is condensation in theTransparent Chamber. Is this a problem? This normally happens because of temperature differences. It does not affect the working of your Pureit Advanced and you will continue to receive water that is ‘Safer Than Boiled Water’. What happens if some part of the Pureit Advanced breaks accidentally? If some part of Pureit Advanced breaks accidentally, please call Pureit Advanced helpline.We will arrange to send you a replacement part.You will however have to pay for the replacement part. What should I do if it takes a long time to purify water? In case the water quality is bad the filtration units of Pureit Advanced may take a longer time to purify water. In such cases you will need to clean the Carbon Polisher™ and the Advanced Microfiber MeshTM . Please refer the ‘Cleaning Maintenance of Pureit Advanced’ section for this. If the flow rate still does not improve them please clean the Microcharged Membrane as shown in the ‘Cleaning Maintenance’ section. How do I know that my Pureit Advanced needs cleaning? In case the water quality is bad the filtration units of Pureit Advanced may take a longer time to purify water.There will be a time when the water stops coming into the Transparent Chamber.This is an indication that you need to clean your Pureit Advanced. Please refer the ‘Cleaning Maintenance of Pureit Advanced’ section for this. Pureit Advanced didn’t fully remove the colour from the input water. Is the water safe to drink? Such a situation will normally not happen in PureitAdvanced. All the colloidal clay,insoluble salts of calcium,magnesium,iron etc will be removed by the Microcharged Membrane.Such a situation if happens,suggests that Microcharged Membrane has been damaged.Please call the PureitAdvanced helpline for replacement. Can there be scaling in Pureit Advanced? Dissolved chemicals in water can occasionally precipitate out of the water,and deposit inside PureitAdvanced.This however does not in any way affect the Germkill capability of PureitAdvanced. To avoid scaling,rinse theTop Chamber Transparent Chamber once in a while.Do not use any abrasive cleaners or tools.Refer to Cleaning Maintenance of PureitAdvanced section for details.
  • 35. 33 FAQs Will Pureit Advanced remove salt and oil? Input water may contain many materials which affect the taste of water. Of these, Pureit Advanced removes materials like oil, sand, soil, clay, dirt, decayed animal and plant waste, and harmful pesticide impurities and is therefore likely to improve the taste of water. However, Pureit Advanced does not remove some dissolved salts that may contribute to taste like sodium chloride salt, calcium and magnesium. In fact, Pureit Advanced retains some ‘good’ dissolved salts present in drinking water. This may affect the taste of water. Can one pour brackish water into Pureit Advanced? Yes, the water will be free of harmful germs, but there may not always be an improvement in taste. However by pouring brackish/sea water into the Pureit Advanced, there may be a risk of choking the system, and the ‘Auto Shut-Off™’ mechanism may malfunction. Can there sometimes be particles in the water stored in theTransparent Chamber? No. Particles will not escape into the Transparent Chamber through the filtering media. However you have to drain the first cycle that gets collected in the Transparent Chamber. Sometimes there is a chlorine like smell near the Germkill Processor™. Is this a problem? No, this is not a problem.You will continue to get absolutely safe, odour free, great tasting water from the Transparent Chamber. Water is overflowing from the front of the purifier? There might be two reasons for this. One, check your Germkill Life Indicator™. If it is red, then please order for a new Germkill Kit™ and replace it. Do not pour any more water in the Top Chamber to avoid further spillage.Two, if the Germkill Indicator is not red, please clean the Carbon Polisher™ and the Advanced Microfiber MeshTM and ensure proper placement of all parts in the Cleansing Collection Chamber. If the problem persists, then please contact Pureit Advanced Helpline. How long does it take for the water to get purified? It depends on the quality of water that is put into Pureit Advanced.Typically 9 litres of water gets purified between 1.5-2 hrs. Cleaning the Carbon Polisher™ and the Advanced Microfiber MeshTM regularly can also improve the flow rate. Do I need to empty the water from PureitAdvanced if I am not using the purifier for a few days. If there is stagnant water in Pureit Advanced for more than 2 days, then discard one cycle of water and start consuming from the fresh cycle of water.
  • 36. 34 A³ga nyNo OmZo dmbo gdmb Q´m§gna|Q Moå~a ‘| H§$SoÝgoeZ hþAm h¡ ³¶m ¶h EH$ g‘ñ¶m h¡? Vmn‘mZ ‘| ’$H©$ Ho$ H$maU Am‘Vm¡a na Eogm hmoVm h¡ Bggo AmnHo$ ߶mo[aQ ESdmÝgS Ho$ H$m¶© na Aga Zht hmoJm Am¡a AmnH$mo ‘C~bo nmZr go µÁ¶mXm gwa{jV nmZr’ {‘bZm Omar ahoJm ߶mo[aQ ESdmÝgS H$m H$moB© nwOm© hmXgo ‘| AMmZH$ QyQ J¶m Vmo ³¶m hmoJm? ߶mo[aQ ESdmÝgS H$m H$moB© nwOm© AJa hmXgo ‘| QyQ J¶m Vmo H¥$n¶m ߶mo[aQ ESdmÝgS hoënbmB©Z H$mo H$m°b H$a| h‘ CgHo$ ~Xbo Xÿgam nwOm© ^oOZo {H$ ì¶dñWm H$a|Jo hmbm§{H$ Cg ~Xbo hþE nwO} H$s H$s‘V MwH$mZr hmoJr AJa nmZr ewÕ hmoZo ‘| Á¶mXm g‘¶ bJVm h¡ Vmo ‘wPo ³¶m H$aZm Mm{hE? “AJa nmZr H$s J{V ‘| {µ’$a ^r ~TmoVr Zht AmVr h¡ Vmo ‘mBH«$moMmÁS© ‘oå~«oZ ‘߶mo[aQ ESdmÝgS H$s gµ’$mB© Am¡a aI aImd Ho$’ g§X^© ‘| gmµ’$ H$a|” ‘wPo H¡$go nVm MboJm {H$ ‘oar ߶mo[aQ ESdmÝgS H$mo g’$mB© H$s OéaV h¡ ? ¶{X nmZr H$s JwUdÎmm ~hþV Iam~ h¡ Vmo nmZr ewÕ H$aZo ‘| ~hþV g‘¶ bJ gH$Vm h¡ Hw$N g‘¶ ‘| Q´m§gna|Q M|~a ‘| nmZr AmZm ~§X hmo Om¶oJm ¶h Bg ~mV H$m g§Ho$V h¡ {H$ AmnH$mo AnZo ߶mo[aQ ESdmÝgS {H$ g’$mB© H$aZr Mm{hE H¥$n¶m BgHo$ {bE ‘߶mo[aQ ESdmÝgS H$s g’$mB© Am¡a aI aImd’ IÊS H$m g§X^© b| ߶mo[aQ ESdmÝgS Zo AÝXa AmZo dmbo nmZr go a§J nyar Vah go Zhr {ZH$mbm ³¶m dh nmZr nrZo Ho$ {bE gwa{jV h¡ ? Eogr pñW{V ߶mo[aQ ESdÝgS ‘| CËnÝZ Zhr hmoJm g~ {‘År VWm H¡$pëg¶‘, ‘½Zo{g¶‘ Am¡a bmohm Ho$ AKwbZerb bdU H$mo ‘mBH«$moMmÁS© ‘oå~«oZ ~mha {ZH$mb XoVm h¡ O~ Eogr pñW{V CËnÞ hmo Vmo g‘P bmo H$s ‘mBH«$moMmÁS© ‘oå~«oZ j{VJ«ñV hmo MwH$m h¡ H¥$n¶m Bgo ~XbZo Ho$ {bE ߶mo[aQ ESdmÝgS hoënbmB©Z go g§nH©$ H$a| ³¶m nmo[aQ ESdmÝgS ‘| ñHo$qbJ (jma H$s naV) hmo gH$Vr h¡? nmZr ‘| ^§J agm¶Z H$^r H$^r nmZr go ~mha VbNQ H$a gH$Vo h¢, Am¡a ߶mo[aQ ESdmÝgS Ho$ A§Xa O‘m hmo gH$Vo h¢ ¶h, {H$gr ^r Vah go ߶mo[aQ ESdmÝgS H$s O‘©{H$b j‘Vm H$mo à^m{dV Zht H$aVm h¡ ñHo$qbJ amoH$Zo Ho$ {bE H$^r H$^r Q´m§gna|Q M¡å~a Am¡a Q°mn M¡å~a H$s g’$mB© H$s{OE {H$gr ^r AnKf©H$ ³brZa ¶m CnH$aUm| H$m Cn¶moJ Z H$a| {ddaUm| Ho$ {bE ‘߶mo[aQ ESndmÝgS H$s g’$mB© Am¡a aI aImd’ IÊS go g§X^© b| ³¶m ߶mo[aQ ESdmÝgS jma VWm Vob {ZH$mb nmEoJm? ߶mo[aQ ESdmÝgS ‘| Smbo OmZodmbo nmZr ‘| H$B© nXmW© hmo gH$Vo h¢ Omo nmZr Ho$ ñdmX na Aga SmbVo h¢ BZ‘| go ߶mo[aQ ESdmÝgS Vob, aoVr, {‘År, Yyb, àmUr VWm dZñnVr¶m| H$m g‹Sm hþAm H$Mam, Am¡a hm{ZH$maH$
  • 37. 35 A³ga nyNo OmZo dmbo gdmb H$sQZmeH$ AewÕ VËd O¡go nXmW© hQm XoVm h¡ VWm Bggo nmZr Ho$ ñdmX ‘| ~ohVar hmo gH$Vr h¢ hmbm§{H$, ߶mo[aQ ESdmÝgS no¶Ob ‘| CnpñWV Hw$N Kwbo hþE jma O¡go gmo{SA‘ ³bmoamB©S g°mëQ, H$°pëe¶‘ VWm ‘°½Zo{e¶‘ H$mo Zht {ZH$bVm h¡ Am¡a Hw$N bm^H$mar Kwbo hþE jma H$mo ߶mo[aQ ESdmÝgS ~aH$ama aIVm h¡ Bggo nmZr Ho$ ñdmX na à^md n‹S gH$Vm h¡ ³¶m h‘ ߶mo[aQ ESdmÝgS ‘| Z‘H$sZ nmZr Smb gH$Vo h¢? Or hm§, ¶h nmZr hm{ZH$maH$ {H$QmUwAm| go ‘w³V hmoJm, bo{H$Z CgHo$ ñdmX ‘| h‘oem ~ohVar hmoJr Eogm Zhr h¡ g‘wÐ Ho$ Imam nmZr H$mo ߶mo[aQ ESdmÝgS ‘| SmbZo go ¶ÝÌ ‘| KwQZ CËnÝZ hmo gH$Vm h¡ Am¡a Am°Qmo eQ-Am°µ’$™ V§Ì H$s Iam~r hmo gH$Vr h¡ Q´m§gna|Q Moå~a ‘| O‘m {H$E JE nmZr ‘| ³¶m H$^r H$U hmo gH$Vo h¢ ? Zht {µ’$ëQatJ ‘mܶ‘ go Q´m§gna|Q Moå~a ‘| H$moB© ^r H$U Zht OmEJm {µ’$a ^r AmnH$mo Q´m§gna|Q Moå~a ‘| nhbo gmBH$b ‘| EH${ÌV nmZr H$mo {ZH$mb XoZm Mm{hE H$^r - H$^r O‘©{H$b àmogoga™ Ho$ nmg ³bmoarZ O¡gr J§Y AmVr h¡, ³¶m ¶o H$moB© g‘ñ¶m Vmo Zht h¡ ? Or Zht, ¶h H$moB© g‘ñ¶m Zht h¡ AmnH$mo Q´m§gna|Q M|~a go Cgr Vah gmµ’$ - ñdÀN, ~ohVarZ ñdmX dmbm Am¡a J§Y a{hV nmZr {‘bVm ahoJm nmZr ߶mo[a’$m¶a Ho$ gm‘Zo go Amodaâbmo hmo ahm h¡ ? BgHo$ Xmo H$maU hmo gH$Vo h¡ nhbm, O‘©{H$b bmB’$ B§SrHo$Qa {H$ Om§M H$ao ¶{X dh bmb a§J H$m h¡, Vmo H¥$n¶m O‘©{H$b {H$Q™ ‘±JmE Am¡a Cgo ~Xb Xo Eogr pñW{V ‘| Q°mn Moå~a ‘| Am¡a nmZr Z Smb| Xÿgam, ¶{X O‘©{H$b B§SrHo$Qa bmb a§J H$m Zht h¡ Vmo H¥$n¶m H$m~©Z nm°{bea Am¡a ESdmÝgS ‘mBH«$mo’$mB~a ‘oe™ H$mo gmµ’$ H$a| Am¡a g~ KQH$m| H$mo AÀNr Vah go ³boqµOJ H$bo³eZ Moå~a ‘| gpå‘{bV H$a Xo§ ¶{X {’$a ^r g‘ñ¶m aho Vmo H¥$n¶m ߶mo[aQ ESdmÝgS hoënbmB©Z go g§nH©$ H$a| nmZr H$mo ewÕ hmoZmo ‘| {H$VZm g‘¶ bJVm h¡ ? ߶mo[aQ ESdmÝgS ‘| SmbZo dmbm nmZr H$s JwUdÎmm na ¶h {Z^©a hmoVm h¡ Am‘Vm¡a na 9 {bQa nmZr 1.5-2 KÝQo ‘| ewÕ hmo OmVm h¡ H$m~©Z nm{bea™ Am¡a ESdmÝgS ‘mBH«$moµ’$mB©~a ‘oe™ H$mo {Z¶{‘V gmµ’$ H$aZo go àdmh Xa ^r gwYaVr h¡ AJa ‘¢ H$B© {XZm| VH$ ߶mo[aQ ESdmÝgS BñVo‘mb Z H$é± Vmo ³¶m ‘wPo Cg‘| go nmZr {ZH$mb H$a Cgo Imbr H$a XoZm Mm{hE? AJa ߶mo[aQ ‘| 2 {XZ go Á¶mXm éH$m hþAm nmZr h¡ Vmo nmZr H$m EH$ gmBH$b H$mo {ZH$mb X| Am¡a nmZr Ho$ Z¶o gmBH$b go Cn¶moJ àma§^ H$a|
  • 38. 36 Warranty Registration Card Serial no. Purchaser’s name Telephone no. Address    Dealer’s name Address Date of purchase ______________________________ Dealer’s Signature (with rubber stamp) Removes 1 Crore virus in 1 Litre of water* Note: 1. Please retain the bill of purchase. 2. Please quote the serial number, model date of purchase in all your correspondence. 3. Call Pureit helpline to upate your details into our database.
  • 39. 37 pureit advanced warranty details Product warranty The Pureit advanced purifier guarantees that you will get ‘Safer Than Boiled Water’ as long as the purifier is used in the manner specified in this manual. In addition, we cover your Pureit advanced purifier with a six-month warranty against manufacturing defects. General For the purpose of this warranty, the following expressions shall have the following meanings respectively: ‘The purifier’ shall mean the purifier described in the invoice. ‘The customer’ shall mean the purchaser of the purifier from the company or the company’s authorised dealer who is a party to the invoice. ‘The company’ shall mean Hindustan Unilever Limited. ‘Invoice’ shall mean the Invoice issued for the purifier by the retailer to the customer describing the purifier and indicating, inter alia, the total purchase price thereof, the name and address of the customer. ‘User manual’ shall mean the instructions for installation, use and maintenance contained in the leaflet published by the company, and delivered to the Customer at the time of sale of the purifier.
  • 40. 38 pureit advanced warranty details This warranty is subject to the following conditions The customer will notify the company in writing or by calling the helpline promptly of any defects noticed and give the company or its authorised agent adequate opportunity to inspect, test and remedy them for which the customer will deposit the purifier if so required by the company, with the company’s office/service centre/authorised dealer along with the original invoice, in the city where it was sold. The company’s obligation under this warranty shall be limited to repairing or providing replacement of parts, found to be defective. The company or its authorised agent will be entitled to retain any defective part replaced under the warranty. Inspection and test report of the company’s office/service centre/authorised dealer will be final and binding under the warranty for determining defects, repairs/alterations required or carried out, or certifying working of the purifier thereafter. The company’s liability under this warranty shall in no event, and under no circumstances, exceed the price paid by the customer. This warranty is confined to the first purchaser of the product only and is not transferable. In the event of repairs of any part/s of the purifier, this warranty will thereafter continue and remain in force only for the unexpired period of the warranty. The warranty is issued at Mumbai, and courts at Mumbai shall have exclusive jurisdiction over matters covered or flowing from this warranty. The company’s obligation is only for effective repairs of any defective part of the purifier, and not for purifier replacement as such. Repairs or replacements will be carried out by the company’s office/service centre/authorised dealer from whom the purifier has been purchased. For purifiers installed beyond the municipal limits of the jurisdiction of the authorised service centre/authorised dealer, all expenses incurred in collecting the purifier/s, or parts thereof from the company’s service center/authorised dealer, as well as expenses incurred with deputising of service personnel/technicians towards conveyance and other incidentals etc. shall be borne by the customer. The warranty is void if any repair work is carried out by persons other than those of the company, or its authorised dealers. The warranty is void if the serial number is deleted from the bottom of the purifier. This warranty is valid in India only. Notwithstanding anything to the contrary contained in, or implied by this warranty: The company’s liability under this warranty shall be limited only to defects in the purifier which occur under the conditions of normal operation of the purifier and it's proper and prescribed use as per this user manual. This warranty does not cover or extend to defects which are determined by the company or its authorised agents as occurring or resulting from or attributable to negligence, abuse, misuse, faulty care, operation or maintenance or repairs, alterations to the purifier or any part thereof by others. The three components of the Germkill Kit™ are not covered by this warranty, and have to be separately bought by the consumer once their life is over. Visit the Pureit website for more detailed instructions on cleaning maintenance of your purifier Warranty doesn’t cover any damage/other issue arising out of ingress of external/foreign material (like dust, insects, ants, other pests) in the water purifier as it is the responsibility of the consumer to keep the area around the purifier clean and free of pests/dust.
  • 41. 39 Technical specifications for pureit ADVANCED ߶mo[aQ ESdmÝgS H$s VH$ZrH$s OmZH$mar Pureit Advanced / ߶mo[aQ ESdmÝgS Height / D§$MmB© 61 cms / 61 g|. ‘r Width / Mm¡‹SmB© 33 cms / 33 g|. ‘r Depth / JhamB© 36 cms / 36 g|. ‘r Weight / dµOZ 3.7 kgs / 3.7 {H$ J«m Total purifier volume / nyao ߶moar’$m¶a H$s j‘Vm 23 litres / 23 brQa Water storage capacity / nmZr ^§SmaU H$s j‘Vm 9 litres / 9 brQa Material of construction {Z‘m©U gm‘J«r Food safe, non-toxic, engineering plastics ImÚ J«oS, J¡a {df¡bo A{^¶m§{ÌH$s ßbmpñQH$ Germkill Kit™ / O‘©{H$b {H$Q™ Material of construction / {Z‘m©U gm‘J«r Food safe, non-toxic, engineering plastics / ImÚ J«oS, J¡a {df¡bo A{^¶m§{ÌH$s ßbmpñQH$ Purification capacity ߶mo[a{’$Ho$eZ j‘Vm The Germkill Kit™ has been designed to typically give 1500 litres (under standard test conditions^) of Safer Than Boiled Water~ / O‘©{H$b {H$Q™ H$mo bJ^J 1500 brQa (à¶moJembo¶ narjU pñW{V^ Ho$ A§VJ©V) C~bo nmZr go µÁ¶mXm gwa{jV nmZr~ XoZo Ho$ {bE ~Zm¶m J¶m h¡. Expiry period / OrdZ Ad{Y Two years from the date of manufacturing / {Z‘m©U {V{W go Xmo df© Germkill performance standard O‘©{H$b àXe©Z ‘mZH$ Meets stringent international criteria of the Environmental Protection Agency (EPA), USA, for harmful viruses bacteria removal EZdm¶a‘|Qb àmoQo³eZ EO|gr (B© nr E). ¶y Eg Eo. hm{ZH$maH$ ~¡³Qo[a¶m Am¡a dmBagm| {Z‘y©bZ Ho$ H$‹So ‘mn X§Sm| na Iam CVaVm h¡ ^Standard test conditions / ^ ñQ¢SS© narjU pñW{V¶m± - • Water temperature: 23° C / nmZr H$m Vmn‘mZ… 23° C • Relative Humidity: 55% to 65% / àmg§{JH$ AmЩVm… 55% go 65% • Water quality parameters / nmZr H$s JwUdÎmm Ho$ n¡am‘rQa - TDS: 300+/- 10 PPM / QrSrEg… 300+/-10 nrnrEg - PH: 7.5+/- 0.5 / nrEM… 7.5+/-0.5 - TOC: 1 PPM / QrAmogr… 1 nrnrE‘ - Turbidity: 1 NTU / Q~u{SQr… 1 EZQr¶y ~ As per Independent LabTests Pureit removes lead from input water whereas boiling cannot.
  • 42. 40 statement of hindustan unilever’s intellectual property rights Products covered under Hindustan Unilever’s intellectual property rights Pureit™ Microfibre Mesh™ Germkill Kit™ Activated CarbonTrap™ Germkill Action™ Germkill Processor™ Germkill Life Indicator™ Polisher™ © HUL 2010
  • 43.
  • 44. Central Food Technological Research Institute National Environmental Engineering Research Institute Apollo Hospitals, Chennai Institution of Public Health Engineers, India Indian Public Health Association Certifications Setting benchmarks in water purification Winning laurels across the world No.1 choice of families Worldwide - India - Mexico - Indonesia - Brazil - Bangladesh Pureit is the world’s largest selling water purifier brand# *Representation of the US EPA torture test of 4 log virus removed from 1 ml of contaminated water. # Based on Unit shipment sales for 2013. Excludes pitchers and faucet mount systems sales and includes only in-home point-of-use drinking water treatment systems. ~ As per Independent LabTests Pureit removes lead from input water whereas boiling cannot.