1. G.SRINIVASAN.
12 Kishore Bhai Compound,
Joglekerwadi, Sion East
Mumbai – 400 022, India.
Land Line: 9122 24025622,
Mobile No: 91 9320513338.
SKYPE :SRINIVASANGSUBBAIAH
srinivasang59@rediffmail.com, srinivasang59@yahoo.com,srinivasansubbaiah@gmail.com
Objective : To find a suitable position in professionally managed organization
and to lead the team in achieving its goals.
Qualifications : S.S. L.C TAMIL NADU, INDIA
Tech. Qualification :DIPLOMA IN ELECTRICAL ENGINEERING.
Total Experience : 18 years.
Diploma in Electrical and Electronics Engineering.
• 18 years experience in maintenance and commissioning of
Electrical equipment’s in the field of oil and gas exploration, refinery,
Petrochemical plants in various countries offshore and
onshore sites.
Familiar with international standard codes, hazardous area classification
and safe working practices.
Undergone various trainings and courses.
Basic computer literacy.
Permit to Work System (PTW), STOP awareness.
Lock Out / Tag Out (LOTO)
Confined Space Entry, H2S & Breathing Apparatus (QATAR)
Personal Safety & Social Responsibilities.
Job Safety Analysis (JSA).
2. From To Employer
March 2015 January 2016 CTJV (Qatar gas LR2
project)at Qatar
March 2014 May 2014 Samsung Eng Ltd Qatar
Gas
June 2013 Aug,2013 Brunel,Adco,U.A.E
Oct 2012 May,2013 Petrofac, Algeria, Elmerk
Dec 2011 April, 2012 Technimount ,U.A.E
March2011 May , 2011 Brunel,Dubai ,U.A.E.
March 2010 June 2010 Brunel India Ltd
November 2009 February 2010 Qatar Consilium
May 2009 Aug 2009 Qatar Kentz
Qatar
January 2009 March 2009 Borouge.
Abu Dhabi
May 2008 August 2008 Jal International.
Petrokemiya
Saudi Arabia
October 2006 June 2007 Senimdi & Kurlys.
Kazakhstan Bechtel
February 2006 May 2006 Black cat, Doha Qatar.
Qatar Petroleum.
October 2004 June 2005 LTA Aljaber Grinaker,
Abu Dhabi
February 2002 January 2004 CDC (W.L.L) West Bay
Complex
Doha Qatar
November 1998 February 2000 ZAMMR Co. LTD.
Saudi Arabia for Yanpet
Expansion Project.
January 1996 October 1998 International Engg.
Marine
Works (O.N.G.C ) Oil Rig.
3. General Maintenance & checks:
Maintenance experience in Generators, transformer, switchgears, motors and
variable frequency drives and etc.
o All motor Maintenance in the rating of 430 KW, Maintenance of HVAC &
o AHU Unit.
o Maintenance of 11KV/420V-1600KVA & 11KV/3.45V 2000KVA Transformers
(ABB).
o Maintenance of Emergency Diesel Generator and Fire water pumps.
o Maintenance of Utility air Compressor. (INGERSOLL RAND, SULAIR).
o Maintenance of UPS in the range of 85KVA (GUTOR)
o GE Gas Turbine coupled ALSTOM Motor11KV /and its control & VFD panel’s.
o AREVA 415V MCC Panels and protections.
o AREVA 11KV, Switchgear & Protections.
o 110 KVA AC and 40KVA DC UPS and batteries
o Electrical equipment’s and solo run test of motors
o General Cleaning & Operational Checks of D.C Motors ,A.C Motors & control
o Air-conditioning Compressors & Transformers & Auxiliary Transformers,
Lighting Panel & Navigation Lights
o AREVA 11KV,& 6.6kV Switchgear LV 600KV&MCC Panels and
o TRASFOR 11KV,& 6.6kV Transformers ,Motors and protections
o Emergency lighting , normal lighting , ups lighting testing & commissioning
o AREVA 11KV,& 6.6kV Switchgear LV 600KV&MCC Panels and
o TRASFOR 11KV,& 6.6kV Transformers ,Motors and protections
o Emergency lighting , normal lighting , ups lighting testing & commissioning
b.) Preventive Maintenance:-
o Meggaring of D.C Motors Winding & A.C Motors Winding.
o Cleaning of contracts of Starter & Breakers.
4. o Replaced Bearing on Big & Small Motors & Greasing Motors & Tightening of Motors
Terminals.
o Cleaning of Commutator & Insulators & Checking Carbon brushes.
o Chipping & Painting of A.C Motors & D.C Motors.
o Check Earthling of Lighting Circuit and pin point fault.
o Topping of Distilled Water Cleaning & Greasing of Terminals of Battery Bank.
o Filling of Freon gas in condenser & Cleaning of condenser tubes & A.H.U.
c.)
Break Down / Incidental Repairs:-
o Replace A/C Module and check Functioning & Pressure, Switch, solenoid
o Replace D. C module in panel and D.C contractors.
o Overhauling of S C R, Blower Assy.
o Replace space heater in DC motors & DC Motors Blower & Throttle.
o Changing Sensors, Meters & Gauges.
o Adjustments of motors Break and Limit Switch.
o Repairing of HPMV Light assy & Emergency Light assy.
Tube Light fitting, Heledeck Light & Navigational light.
DETAILS OF WORK PERFORMED IN TESTING &
COMMISSIONING AND STARTUP.
Having good exposure in Testing, Commissioning, Operation & Maintenance & Trouble
shooting of following Electrical Equipment.
o Erection & Commissioning from 415 swgr to 132 KV switchyard
o All electrical equipment testing and commissioning like CT,PT,Transformers,HT
panels,LT panels and control &Relay panels
o Motor control center
o Control &Protection panel of T.G, D.G ,Transformer &H.T.Motor
o V.C.B,SF6, A.C.B
o Transformer (150KVA-100MVA) with Differential protection and REF protection
o Battery Bank (40Ah-700Ah)
o Bus bar protection
5. o Capacitor Bank (7.2 MVAR) Testing.
o 100 MVA Transformer testing with Differential & REF protection
Vacuum integrated test in vaccum circuit breaker.
Transformer Neutral Earth Resistor test.
Equipments Handled :--
Transformers: Up to 132 KV, 100 MVA, oil and hermetically sealed types. Covering
examinations including nitrogen filling and leakage test, insulation resistance, parallel
operation condition, energisation fault investigation, rectification, testing and maintenance
of transformers and its accessories.
Switch Gears: Up to 33 KV. SF6, Vacuum, Air, and Oil circuit breakers, power and
motor control centers, isolators, bus ties and bus duct systems.
Covering examination, general maintenance including contact
resistance, insulation test, service checks, and fault investigation.
PCC and MCC : Operation and maintenance of Power control center and motor
control center with switchgear room and pressurization substation.
Gas Turbine : Experienced with GTA U 42 MVA/11KV Power Turbines Operation
and maintenance activities.
Generator : Operation and maintenance of emergency Gen. sets (Up to 2072
KVA). With change over synchronizing and related accessories.
Motors : Up to 11 KV covering vibration test, insulation resistance test.
Rectification of faults and general maintenance.
UPS /
Battery Charges: Up to 110 KVA UPS in different manufactures, all type of batteries
Batteries : covering maintenance and fault rectification.
MOV and : Testing and maintenance of MOV, Cranes and its fault rectification.
Cranes
:
o Replace A/C Module and check Functioning & Pressure, Switch, solenoid
o Replace D. C module in panel and D.C contractors.
6. o Overhauling of S C R, Blower Assy.
o Replace space heater in DC motors & DC Motors Blower & Throttle.
o Changing Sensors, Meters & Gauges.
Personal Details:
Date of Birth : 7th
July, 1971
Marital Status : Married
Passport Details : M – 7015299 OLD PASSPORT NOs :- F- 4187878 , U–544953
Date of Issue : 3rd
March 2015.
Date of Expiry : 2nd
March 2025.
Place of Issue : Mumbai
I Assure you Sir that I will prove Worthy of my Selection
With my Above Vast Experience and Request your good Self
Kindly Bestow Me With Suitable Appointment in Your Organization.
Awaiting your early favorable Orders.
Yours Faithfully,
(G.SRINIVASAN)
7. o Overhauling of S C R, Blower Assy.
o Replace space heater in DC motors & DC Motors Blower & Throttle.
o Changing Sensors, Meters & Gauges.
Personal Details:
Date of Birth : 7th
July, 1971
Marital Status : Married
Passport Details : M – 7015299 OLD PASSPORT NOs :- F- 4187878 , U–544953
Date of Issue : 3rd
March 2015.
Date of Expiry : 2nd
March 2025.
Place of Issue : Mumbai
I Assure you Sir that I will prove Worthy of my Selection
With my Above Vast Experience and Request your good Self
Kindly Bestow Me With Suitable Appointment in Your Organization.
Awaiting your early favorable Orders.
Yours Faithfully,
(G.SRINIVASAN)