SlideShare a Scribd company logo
1 of 55
Download to read offline
Página
| 1
Página
| 2
Table of Contents: Coaxial Cable Series
Coaxial RF 50 Cupper and Aluminum
Cooper – Pag.5 Aluminum – Pag.13 Jumpers – Pag.19 Jumpers Low PIM
Grounding Kits–Pag.23 Arrestors – Pag. 52 Clamps – Pag.24 Tools – Pag. 53
Connect 1/2"–Pag.31 Superflex 1/2"–Pag.37 Connect 7/8"–Pag.43 Connect 1-5/8"–Pag.48
Página
| 3
Página
| 4
Coaxial Cable - Comparison of different cable types
The product range includes high- frequency coaxial connectors and cables, RF- test & measurement products, as well as
infrastructure site solutions, connectors, cables or accessories for radio base stations.
Image Overview Type Section Inner conductor Outer conductor Jacket options Order number
Superflexible Cables SilexFlex
1/4" Copper-Clad Aluminum Wire Corrugated Copper Tube
PE
LCF14HR
HL-FR-Z LCF14HRZ
3/8" Copper-Clad Aluminum Wire Corrugated Copper Tube
PE LCF38HR
HL-FR-Z LCF38HRZ
1/2" Copper-Clad Aluminum Wire Corrugated Copper Tube
PE LCF12HR
HL-FR-Z LCF12HRZ
Flexible Cooper Cables SilexStd
1/4" Copper-Clad Aluminum Wire Corrugated Copper Tube
PE LCF14STD
HL-FR-Z LCF14STDZ
3/8" Copper-Clad Aluminum Wire Corrugated Copper Tube
PE LCF38STD
HL-FR-Z LCF38STDZ
1/2" Copper-Clad Aluminum Wire Corrugated Copper Tube
PE LCF12STD
HL-FR-Z LCF12STDZ
5/8" Smooth Copper Tube Corrugated Copper Tube
PE LCF58STD
HL-FR-Z LCF58STDZ
7/8" Smooth Copper Tube Corrugated Copper Tube
PE LCF78STD
HL-FR-Z LCF78STDZ
1-1/4" Smooth Copper Tube Corrugated Copper Tube
PE LCF114STD
HL-FR-Z LCF114STDZ
1-5/8" Helical Copper Tube Corrugated Copper Tube
PE LCF158STD
HL-FR-Z LCF158STDZ
2-1/4" Helical Copper Tube Corrugated Copper Tube
PE LCF214STD
HL-FR-Z LCF214STDZ
Flexible Aluminum
Cables
SilexStl
1/2" Copper-Clad Aluminum Wire
Corrugated Aluminium
Tube
PE LCF12STL
HL-FR-Z LCF12STLZ
7/8" Smooth Copper Tube
Corrugated Aluminium
Tube
PE LCF78STL
HL-FR-Z LCF78STLZ
1-1/4" Smooth Copper Tube
Corrugated Aluminium
Tube
PE LCF114STL
HL-FR-Z LCF114STLZ
1-5/8" Helical Copper Tube
Corrugated Aluminium
Tube
PE LCF158STL
HL-FR-Z LCF158STLZ
Jacket: PE
Standard Polyethylene, PE, Metalhydroxite Filling, UV resistant PE jacket, halogen free according to IEC 60754
Jacket: HL-FR-Z
Halogen Free & Fire resistant (Z)
Test on flammability of single cables Test in accordance with: IEC 60332-1-2 EN 60332-1-2
Test on flammability of cable bundles Test in accordance with: IEC 60332-3 Cat. C EN 50266-2-4 Cat. C
Test on smoke density Test in accordance with: IEC 61034-1 and -2 EN 61034-1 and -2
Test on corrosive gas emissions Test in accordance with: IEC 60754-2 EN 50267-2-2
Test on insulation integrity Test in accordance with: IEC 60331-23 VDE 0472 Part 814
Página
| 5
General
LCF12STD(Z)
LCF12STD(Z), Silexstd ® RF Low Density Foam Coaxial Cable 1/2", corrugated
copper, 1/2 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z).
Type HCAAY(Z)-50-12
Construction Materials
Inner Conductor Copper-Clad Aluminum Wire
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Copper Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 4.80 mm
Dielectric Diameter 12.30 mm
Outer Conductor Diameter 13.80 mm
Diameter Over Jacket 15.70 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 50 mm
Repeated Bending 125 mm
Minimum Number of Bends 15
Tensile Strength 1100 N (247 lb)
Electrical Specifications
Capacitance 76.0 pF/m (23.2 pF/ft)
Impedance 50 ± 1 O
Velocity 88%
RF Peak Voltage 1.60 kV
Peak Power Rating 40 kW
Cut-o" Frequency 18.8 GHz
Shielding E"ectiveness>10MHz >120 dB
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 6
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100,00 3,42 1,04 2,23
150,00 4,22 1,29 1,81
200,00 4,90 1,49 1,56
280,00 6,00 1,83 1,27
450,00 7,50 2,29 1,02
800,00 10,20 3,11 0,75
900,00 10,90 3,32 0,71
1000,00 11,60 3,54 0,67
1500,00 14,40 4,39 0,53
1800,00 16,00 4,88 0,48
2000,00 17,00 5,18 0,46
2200,00 17,90 5,46 0,43
2400,00 18,70 5,70 0,42
2500,00 19,30 5,88 0,41
3000,00 21,30 6,49 0,37
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value.
Página
| 7
General
LCF12HR(Z)
LCF12HR(Z), Silexflex ® RF SuperFlexible Foam Coaxial Cable 1/2", corrugated
copper, 1/2 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z).
Type HRCAY(Z)-50-9
Construction Materials
Inner Conductor Copper-Clad Aluminum Wire
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Copper Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 3.60 mm
Dielectric Diameter 8.70 mm
Outer Conductor Diameter 12.00 mm
Diameter Over Jacket 13.30 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 15 mm
Repeated Bending 30 mm
Minimum Number of Bends 15
Tensile Strength 650 N (143 lb)
Electrical Specifications
Capacitance 80.0 pF/m (24.4 pF/ft)
Impedance 50 ± 1 Ω
Velocity 83%
RF Peak Voltage 1.13 kV
Peak Power Rating 19 kW
Cut-off Frequency 12.50 GHz
Shielding Effectiveness>10MHz >120 Db
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 8
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100,00 3,22 0,98 3,03
150,00 4,05 1,23 2,39
200,00 4,65 1,42 2,11
280,00 5,65 1,72 1,69
450,00 7,20 2,19 1,37
800,00 9,86 3,01 1,00
900,00 10,56 3,22 0,94
1000,00 11,15 3,40 0,88
1500,00 13,80 4,21 0,70
1800,00 15,55 4,74 0,63
2000,00 16,40 5,00 0,59
2200,00 17,35 5,29 0,56
2400,00 18,10 5,52 0,53
2500,00 18,50 5,64 0,52
3000,00 20,90 6,37 0,48
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value
.
Página
| 9
General
LCF78STD(Z)
LCF78STD(Z), Silexstd ® RF Low Density Foam Coaxial Cable 7/8”, corrugated
copper, 7/8 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z).
Type HCTAY (Z)-50-22
Construction Materials
Inner Conductor Smooth Copper Tube
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Copper Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 9.00 mm
Dielectric Diameter 22.30 mm
Outer Conductor Diameter 24.90 mm
Diameter Over Jacket 27.50 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 90 mm
Repeated Bending 250 mm
Minimum Number of Bends 15
Tensile Strength 1470 N (330 lb)
Electrical Specifications
Capacitance 75.0 pF/m (22.9 pF/ft)
Impedance 50 ± 1 Ω
Velocity 89%
RF Peak Voltage 3.00 kV
Peak Power Rating 91 kW
Cut-off Frequency 5.20 GHz
Shielding Effectiveness>10MHz >120 dB
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 10
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100,00 1,19 0,36 8,62
150,00 1,47 0,45 7,20
200,00 1,71 0,52 5,99
280,00 2,05 0,62 4,94
450,00 2,64 0,80 3,88
800,00 3,62 1,10 2,83
900,00 3,87 1,18 2,65
1000,00 4,10 1,25 2,50
1500,00 5,16 1,57 1,99
1800,00 5,73 1,75 1,79
2000,00 6,09 1,86 1,68
2200,00 6,44 1,96 1,59
2400,00 6,78 2,07 1,54
2500,00 6,95 2,12 1,50
3000,00 7,74 2,36 1,33
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value.
Página
| 11
General
LCF158STD(Z)
LCF158STD(Z), Silexstd ® RF Low Density Foam Coaxial Cable 1-5/8",
corrugated copper, 1-5/8 in, Black PE or Low Smoke Halogen-free Fire-
retardant (Z).
Type HHTAY(Z)-50-42
Construction Materials
Inner Conductor Helical Copper Tube
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Copper Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 17.40 mm
Dielectric Diameter 42.80 mm
Outer Conductor Diameter 46.50 mm
Diameter Over Jacket 49.50 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 200 mm
Repeated Bending 510 mm
Minimum Number of Bends 15
Tensile Strength 3300 N (750 lb)
Electrical Specifications
Capacitance 76.0 pF/m (23.2 pF/ft)
Impedance 50 ± 1 Ω
Velocity 88%
RF Peak Voltage 5.70 kV
Peak Power Rating 320 kW
Cut-off Frequency 2.80 GHz
Shielding Effectiveness>10MHz >120 dB
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 12
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100,00 0,67 0,20 16,90
150,00 0,84 0,26 13,48
200,00 0,98 0,30 11,60
280,00 1,20 0,37 9,47
450,00 1,53 0,47 7,36
800,00 2,12 0,65 5,26
900,00 2,28 0,69 4,93
1000,00 2,42 0,74 4,61
1500,00 3,09 0,94 3,64
1800,00 3,45 1,05 3,27
2000,00 3,68 1,12 3,00
2200,00 3,91 1,19 2,85
2400,00 4,13 1,26 2,70
2500,00 4,24 1,29 2,61
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value.
Página
| 13
General
LCF12STL(Z)
LCF12STL(Z), Silexstl ® RF Low Density Foam Coaxial Cable 1/2", corrugated
Aluminium, 1/2 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z).
Type HCAAY-L(Z)-50-12
Construction Materials
Inner Conductor Copper-Clad Aluminum Wire
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Aluminium Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 4.80 mm
Dielectric Diameter 12.30 mm
Outer Conductor Diameter 13.80 mm
Diameter Over Jacket 15.70 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 50 mm
Repeated Bending 125 mm
Minimum Number of Bends 15
Tensile Strength 1000 N
Electrical Specifications
Capacitance 76.0 pF/m (23.2 pF/ft)
Impedance 50 ± 1 O
Velocity 88%
RF Peak Voltage 1.60 kV
Peak Power Rating 36 kW
Cut-o" Frequency 8.8 GHz
Shielding E"ectiveness>10MHz >120 dB
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 14
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100,00 2.40 (0.73) 3,58
200,00 3.45 (1.05) 2,50
450,00 5.25 (1.60) 1,64
800,00 7.15 (2.18) 1,21
900,00 7.65 (2.33) 1,14
1000,00 8.10 (2.47) 1,07
1500,00 10.10 (3.08) 0,86
1800,00 11.15 (3.40) 0,78
2000,00 11.85 (3.61) 0,74
2200,00 12.50 (3.81) 0,70
2400,00 13.05 (3.98) 0,68
2500,00 13.40 (4.08) 0,66
3000,00 14.80 (4.51) 0,59
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value.
Página
| 15
General
LCF78STL(Z)
LCF78STL(Z), Silexstl ® RF Low Density Foam Coaxial Cable 7/8", corrugated
Aluminium, 7/8 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z).
Type HCTAY-L (Z)-50-22
Construction Materials
Inner Conductor Smooth Copper Tube
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Aluminium Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 9.00 mm
Dielectric Diameter 22.30 mm
Outer Conductor Diameter 24.90 mm
Diameter Over Jacket 27.50 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 130 mm
Repeated Bending 250 mm
Minimum Number of Bends 15
Tensile Strength 1350 N
Electrical Specifications
Capacitance 75 pF/m(22.9 pF/ft)
Impedance 50 ± 1 Ω
Velocity 88%
RF Peak Voltage 3.00 kV
Peak Power Rating 82 kW
Cut-off Frequency 5.20 GHz
Shielding Effectiveness>10MHz >120 dB
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 16
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100 MHz 1.25 (0.38) 6,50
200 MHz 1.80 (0.55) 4,50
450 MHz 2.77 (0.84) 3,00
800 MHz 3.83 (1.17) 2,20
900 MHz 4.08 (1.24) 2,10
1000 MHz 4.30 (1.31) 2,00
1500 MHz 5.45 (1.66) 1,70
1800 MHz 6.05 (1.84) 1,60
2000 MHz 6.45 (1.97) 1,50
2200 MHz 6.85 (2.09) 1,40
2400 MHz 7.15 (2.18) 1,30
2500 MHz 7.35 (2.24) 1,20
3000 MHz 8.20 (2.50) 1,10
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value.
Página
| 17
General
LCF158STL(Z)
LCF158STL(Z), Silexstl ® RF Coaxial Cable 1-5/8", corrugated Aluminium, 1-5/8 in,
Black PE or Low Smoke Halogen-free Fire-retardant (Z).
Type HHTAY-L (Z)-50-42
Construction Materials
Inner Conductor Helical Copper Tube
Dielectric Physical Foam Polyethylene
Outer Conductor Corrugated Aluminum Tube
Jacket Black PE or Low Smoke Halogen-free Fire-retardant
Physical Dimensions
Inner Conductor Diameter 17.40 mm
Dielectric Diameter 42.80 mm
Outer Conductor Diameter 46.50 mm
Diameter Over Jacket 49.50 mm
Mechanical Specifications
Minimum Bending Radius
Single Bending 200 mm
Repeated Bending 510 mm
Minimum Number of Bends 15
Tensile Strength 3000 N
Electrical Specifications
Capacitance 76.0 pF/m (23.2 pF/ft)
Impedance 50 ± 1 Ω
Velocity 88%
RF Peak Voltage 5.70 kV
Peak Power Rating 290 kW
Cut-off Frequency 2.80 GHz
Shielding Effectiveness>10MHz >120 dB
Insulation resistance 5000M Ω-Km
VSWR
0.8~1.0 GHz ≤1.10
1.7~2.2 GHz ≤1.10
2.2~2.7 GHz ≤1.13
Página
| 18
Environmental Specifications
Storage Temperature -55 ˚C ~ +85 ˚C
Installation Temperature -40 ˚C ~ +60 ˚C
Operation Temperature -55 ˚C ~ +85 ˚C
Perforance - Attenuation
Frequency Attenuation Attenuation Average
MHz dB/100 m dB/100 ft Power Rating (kW)
100 MHz 0.76 (0.23) 15,55
200 MHz 1.09 (0.33) 10,27
450 MHz 1.72 (0.52) 6,46
800 MHz 2.40 (0.73) 4,62
900 MHz 2.58 (0.79) 4,30
1000 MHz 2.74 (0.84) 4,05
1500 MHz 3.50 (1.07) 3,17
1800 MHz 3.94 (1.20) 2,83
2000 MHz 4.20 (1.28) 2,65
2200 MHz 4.46 (1.36) 2,49
2400 MHz 4.74 (1.44) 2,34
2500 MHz 4.86 (1.48) 2,28
3000 MHz - -
Standard Conditions
For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F)
For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F)
Inner Conductor temperature 100 °C (212 °F). No solar loading.
Maximum attenuation value shall be 105% of the nominal attenuation value.
Página
| 19
General Specifications
LCF12STD-xxM-DINF-DINF
Low PIM |-160 dBc
Jumper 1/2" Standard type LCFSTD Silexjpx ® Jumper with interface types
7/16 DIN Female straight to 7/16 DIN Female Low PIM, (xx) Length
Jumpers feature specially designed connectors which are soldered-on in a strictly controlled industrial process. The connector
design and manufacturing process has been optimized to produce premium PIM3, VSWR and IM levels.
The low PIM coaxial jumper cable assemblies have an injection molded boot on each connector which provides added strain relief
and weather sealing ensuring long term durability. Available in 1/2" flexible and 1/2" superflexible coaxial cables, Silexjpx low PIM
coax cables can be ordered in standard and custom lengths with 7/16 DIN and Type N connectors to meet your specific
requirements.
Cable assembly
Series connector 1 7/16
Interface 1 jack straight female
Cable, Nominal Size 1/2〃Standard LCF Type
Series connector 2 7/16
Interface 2 jack straight female
Outline Drawing
Construction Materials
Cable Type 1/2" LCF
Jacket PE or (Z) Fire Retardancy Test Method IEC 60332-1 flame retardant | IEC 60332-3C-24 fire retardant
Smoke Index Test Method IEC 61034 low smoke
Toxicity Index Test Method IEC 60754-1 | IEC 60754-2 smoke emission: halogen free, non corrosive
Connector 1 7/16 DIN Female straight
Connector 1 7/16 DIN Female straight
Specifications Connector Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Sealing class IP68
Página
| 20
Electrical Specifications
Frequency Range DC to 3 GHz
Impedance Ohms 50 Ω
Maximum VSWR 1.15:1
Velocity Propagation 83%
RFShielding 120 dB
PeakPower 16 KWatts
Passive Intermodulation -160 dBc
VSWR (Return Loss, dB) 1.065 (30) @ 1710 - 1990 MHz
1.065 (30) @ 2000 - 2200 MHz
1.083 (28) @ 2200 - 2700 MHz
Environmental Specifications
Installation Temperature, °C(°F) -25 to 60 (-13 to 140 )
Operation Temperature, °C(°F) -50 to 85 (-58 to 185 )
Storage Temperature, °C(°F) -70 to 85 (-94 to 185 )
Jumper Assembly Sample
Example Order Number: LCF12STD4M DINMA DINM
Cable
Types
Length in
Inches Connector 1 - Connector 2 = LCF12STD 4M DINMA DINM
Type Connector
LCF12STD M DIN Male DINM
HCF12STD M DIN Female DINF
LMR240 M
DIN Male Right
Angle DINMA
LMR300 M N Male NM
LMR400 M N Female NF
RG8 M N Male Right Angle NMA Connector 1:DIN Male Right Angle
RG59 M Connector 1: DIN Male 7/16
RG213 M Length: 4 metres
RG214 M Cable Type: LCF12STD
Página
| 21
General Specifications
LCF12HR-xxM-DINMA-DINM
Low PIM |-160 dBc
Jumper 1/2" Standard type LCFSTD Silexjpx ® Jumper with interface types
7/16 DIN Male right angle to 7/16 DIN Male straight Low PIM, (xx) Length
Jumpers feature specially designed connectors which are soldered-on in a strictly controlled industrial process. The connector
design and manufacturing process has been optimized to produce premium PIM3, VSWR and IM levels.
The low PIM coaxial jumper cable assemblies have an injection molded boot on each connector which provides added strain relief
and weather sealing ensuring long term durability. Available in 1/2" flexible and 1/2" superflexible coaxial cables, Silexjpx low PIM
coax cables can be ordered in standard and custom lengths with 7/16 DIN and Type N connectors to meet your specific
requirements.
Cable assembly
Series connector 1 7/16
Interface 1 jack right angle
Cable, Nominal Size 1/2〃Superflex HR Type
Series connector 2 7/16
Interface 2 jack straight
Jumper Assembly Sample
Example Order Number: LCF12STD4M DINMA DINM
Cable
Types
Length in
Inches Connector 1 - Connector 2 = LCF12STD 4M DINMA DINM
Type Connector
LCF12STD M DIN Male DINM
HCF12STD M DIN Female DINF
LMR240 M
DIN Male Right
Angle DINMA
LMR300 M N Male NM
LMR400 M N Female NF
RG8 M N Male Right Angle NMA Connector 1:DIN Male Right Angle
RG59 M Connector 1: DIN Male 7/16
RG213 M Length: 4 metres
RG214 M Cable Type: LCF12STD
Página
| 22
Outline Drawing
Construction Materials
Cable Type 1/2" LCF
Jacket PE or (Z) Fire Retardancy Test Method IEC 60332-1 flame retardant | IEC 60332-3C-24 fire retardant
Smoke Index Test Method IEC 61034 low smoke
Toxicity Index Test Method IEC 60754-1 | IEC 60754-2 smoke emission: halogen free, non corrosive
Connector 1 7/16 DIN Male right angle
Connector 1 7/16 DIN Male straigth
Specifications Connector Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Sealing class IP68
Electrical Specifications
Frequency Range DC to 2.7 GHz
Impedance Ohms 50 Ω
Maximum VSWR 1.11:1
Velocity Propagation 83%
RFShielding 120 dB
PeakPower 16 KWatts
Passive Intermodulation -160 dBc
VSWR (Return Loss, dB) 1.065 (30) @ 1710 - 1990 MHz
1.065 (30) @ 2000 - 2200 MHz
1.083 (28) @ 2200 - 2700 MHz
Environmental Specifications
Installation Temperature, °C(°F) -25 to 60 (-13 to 140 )
Operation Temperature, °C(°F) -50 to 85 (-58 to 185 )
Storage Temperature, °C(°F) -70 to 85 (-94 to 185 )
Página
| 23
General Specifications
GROUNDING KITS
SLXGKM 3/8", 1/2", 7/8", 1-5/8
This Grounding Kit has been developed for copper and aluminum
cable series. The Grounding Kit body facilitates a proper attachment
to the coaxial cable, ensuring that the performance of the coaxial cable.
The tin plated copper mesh provides a secure, low resistance contact to the cable outer conductor. The installation is
fast and simple.
Electrical Specifications
Item SLXGKM Type
Grounding Wire Length 1 m or Customized
Cable Section Acreage 16/25 mm2
Electric Pressure >500 N
Contact Material Tinned Copper
Wire Braiding
Waterproof Material -
Resistance ≤3 mΩ
Voltage Resistance 80 kA
Power Frequency Withstand
Voltage 35 kV
Insulation Resistance 10 GΩ
Earth Resistance 2 mΩ
Durability >10 years
Suitable Cable 3/8", 1/2", 7/8", 1-5/8
Página
| 24
General Specifications
FEEDER CLAMPS
SLXCL Through Type Feeder Clamp
Stainless steel clamps are applicable to fix feeder cables for microwave and
mobile communication; they are made up of excellent anti-acid steel, will
never rust under weather conditions.
Parts Specifications Materials
C-clamp 5mm SUS304
Towl washer 1mm SUS304
Bolt M8*45 SUS304
Nut Ø8 SUS304
Threaded rod M8*80 SUS304
Plastic clamp 1/2", 7/8'', 1-5/8” PP
Nut Ø8 SUS304
Flat washer Ø8 SUS304
Outdoor clamp for 1/2" Tower CLE Feeder Clamp
SXCL121E SXCL122E SXCL123E SXCL124E
Página
| 25
Outdoor clamp for 7/8" Tower CLE Feeder Clamp
SXCL781E SXCL782E SXCL783E SXCL784E
SXCL781E2 SXCL783E2 SXCL783E2
Outdoor clamp for 1 5/8" Tower CLE Feeder Clamp
SXCL1581E SXCL1582E SXCL1583E
Página
| 26
Outdoor clamp for 1 5/8" Tower CLE Feeder Clamp
SXCL1581E2 SXCL1583E2 SXCL1583E2
Outdoor clamp for 3/8, RG8, RG214 Tower CLE Feeder Clamp
SXCL381E2 SXCL382E2 SXCL383E2
SXCLRG81E2 SXCLRG82E2 SXCLRG83E2
SXCLRG2141E2 SXCLRG2142E2 SXCLRG2143E2
Outdoor clamp for UTP cable 2x7 or 2x11 Tower CLE Feeder Clamp
SXCLUTP271E2 SXCLUTP272E2 SXCLUTP273E2
SXCLUTP2111E2 SXCLUTP2112E2 SXCLUTP2113E2
Página
| 27
Outdoor clamp for FO + DC Tower CLE Feeder Clamp
SXCLFO589131E2 SXCLFO589132E2 SXCLFO589133E2
Outdoor for Tower Through Clamp Hanger Kit
Página
| 28
Indoor CLE Feeder Clamp for 1/2", FO, UTP, RG cables types singles and doubles
Fixings example on steel wire-mesh cable trays
SXCL121I SXCL122I SXCL123I
SXCL781I SXCL782I SXCL783I
SXCL1581I SXCL1582I SXCL1583I
SXCLFO55141I SXCLFO55142I SXCLFO55143I
SXCLFO589131I2 SXCLFO589132I2 SXCLFO589133I2
Página
| 29
Connector & Cable - Comparison of different connector types
Size (1/4") (3/8") (1/2") (5/8") ( 7/8") (1-1/4") (1-5/8")
SilexStdConnectorCableStandardFlex
Coaxial Cable
Standard Code HCAAY-50-6 HCAAY-50-8 HCAAY-50-12 HCTAY-50-16 HCTAY-50-22 HCTAY-50-32 HHTAY-50-42
Silex Code LCF14STD LCF38STD LCF12STD LCF58STD LCF78STD LCF114STD LCF158STD
Connector
Standard Code DINM-1/4"L DINM-3/8"L DINM-1/2"L DINM-5/8"L DINM-7/8"L DINM-1-1/4"L DINM-1-5/8"L
Silex Code CCF14STD716M CCF38STD716M CCF12STD716M CCF58STD716M CCF78STD716M CCF114STD716M CCF158STD716M
Connector
Standard Code DINF-1/4"L DINF-3/8"L DINF-1/2"L DINF-5/8"L DINF-7/8"L DINF-1-1/4"L DINF-1-5/8"L
Silex Code CCF14STD716F CCF38STD716F CCF12STD716F CCF58STD716F CCF78STD716F CCF114STD716F CCF158STD716F
Connector
Standard Code DINMA-1/4"L DINMA-3/8"L DINMA-1/2"L - DINMA-7/8"L - -
Silex Code CCF14STD716MA CCF38STD716MA CCF12STD716MA - CCF12STD716MA - -
Connector
Standard Code NM-1/4"L NM-3/8"L NM-1/2"L NM-5/8"L NM-7/8"L NM-1-1/4"L NM-1-5/8"L
Silex Code CCF14STDNM CCF38STDNM CCF12STDNM CCF58STDNM CCF78STDNM CCF114STDNM CCF158STDNM
Connector
Standard Code NF-1/4"L NF-3/8"L NF-1/2"L NF-5/8"L NF-7/8"L NF-1-1/4"L NF-1-5/8"L
Silex Code CCF14STDNF CCF38STDNF CCF12STDNF CCF58STDNF CCF78STDNF CCF114STDNF CCF158STDNF
Connector
Standard Code NMA-1/4"L NMA-3/8"L NMA-1/2"L - - - -
Silex Code CCF14STDNMA CCF38STDNMA CCF12STDNMA - - - -
Size (1/4") (3/8") (1/2") (5/8") ( 7/8") (1-1/4") (1-5/8")
SilexFlexConnectorCableSuperflex
Coaxial Cable
Standard Code HRCAY-50-5 HRCAY-50-7 HRCAY-50-9
Silex Code LCF14HR LCF38HR LCF12HR
Connector
Standard Code DINM-1/4"H DINM-3/8"H DINM-1/2"H
Silex Code CCF14STDNM CCF38STDNM CCF12STDNM
Connector
Standard Code DINF-1/4"H DINF-3/8"H DINF-1/2"H
Silex Code CCF14STDNF CCF38STDNF CCF12STDNF
Connector
Standard Code DINMA-1/4"H DINMA-3/8"H DINMA-1/2"H
Silex Code CCF14STDNMA CCF38STDNMA CCF12STDNMA
Connector
Standard Code NM-1/4"H NM-3/8"H NM-1/2"H
Silex Code CCF14HRNM CCF38HRNM CCF12HRNM
Connector
Standard Code NF-1/4"H NF-3/8"H NF-1/2"H
Silex Code CCF14HRNF CCF38HRNF CCF12HRNF
Connector
Standard Code NMA-1/4"H NMA-3/8"H NMA-1/2"H
Silex Code CCF14HRNMA CCF38HRNMA CCF12HRNMA
Página
| 30
Connector 7/16 & N Types
SilexConnector offers a variety of connector types for Sliex Cablex Coaxial. Silexst® connectors are
engineered and manufactured to the highest standards, achieving maximum performance.
Silexst® connectors are available in both the male and female versions of type N and type 7/16 DIN
connectors. Can be installed on coaxial cable quickly, easily and consistently.
Precision Products for Demanding Applications
SilexConnect™ high performance connectors are designed for use with both Silexstd® corrugated copper and
Silexstl® corrugated aluminum cables.
They are designed specifically to provide the highest quality connector-cable interface while simplifying and
speeding up connector attachment.
Advantages of Silexst® Connectors & Adaptors
• Ease of Installation
• Completely Weatherproof and Consistent
• Long Life
• Low Intermodulation and VSWR
• Corrosion Resistant
• Silver-plated bodies and silver-plated electrical
• Low PIM
Página
| 31
General
CCF12STD716M
CCF12STD716M SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial
Cable
Type DINM-1/2"L
Nominal size 1/2" in
Interface 7/16 DIN Male
Body Style Straight
Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss ≤0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze/Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal Plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 32
General
CCF12STD716F
CCF12STD716F SilexConnect ® RF 7/16 Din Female Connector for 1/2” Coaxial Cable
Type DINF-1/2"L
Nominal size 1/2" in
Interface 7/16 DIN Female
Body Style Straight
Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 33
General
CCF12STD716MA
CCF12STD716MA SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial
Cable
Type DINMA-1/2”L
Nominal size 1/2" in
Interface 7/16 DIN Male
Body Style Right angle
Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 34
General
CCF12STDNM
CCF12STDNM SilexConnect ® RF N Male Connector for 1/2” Coaxial Cable
Type DINNM-1/2”L
Nominal size 1/2" in
Interface N Male
Body Style Straight
Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Outline Drawing
Página
| 35
General
CCF12STDNF
CCF12STDNF SilexConnect ® RF N Female Connector for 1/2” Coaxial Cable
Type DINNF-1/2” L
Nominal size 1/2" in
Interface N Female
Body Style Straight
Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 36
General
CCF12STDNMA
CCF12STD716NMA SilexConnect ® RF N Male Connector for 1/2” Coaxial
Cable
Type DINNMA-1/2”L
Nominal size 1/2" in
Interface N Male
Body Style Right angle
Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 37
General
CCF12HR716M
CCF12HR716M SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial
Superflex Cable
Type DINM-1/2"H
Nominal size 1/2" in
Interface 7/16 DIN Male
Body Style Straight
Mounting cable Model LCF12HR, HCAAY-50-09
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 38
General
CCF12HR716F
CCF12HR716F SilexConnect ® RF 7/16 Din Female Connector for 1/2” Coaxial
Superflex Cable
Type DINF-1/2"H
Nominal size 1/2" in
Interface 7/16 DIN Female
Body Style Straight
Mounting cable Model LCF12HR, HCAAY-50-09
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 39
General
CCF12HR716MA
CCF12HR716MA SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial
Superflex Cable
Type DINMA-1/2”H
Nominal size 1/2" in
Interface 7/16 DIN Male
Body Style Right angle
Mounting cable Model LCF12HR, HCAAY-50-09
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating
Insulator PTFE or TPX PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating
Gasket Silicon Rubber Silicon Rubber
Durability >500 cycle >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 40
General
CCF12HRNM
CCF12HRNM SilexConnect ® RF N Male Connector for 1/2” Coaxial Superflex
Cable
Type DINNM-1/2”H
Nominal size 1/2" in
Interface N Male
Body Style Straight
Mounting cable Model LCF12HR, HCAAY-50-09
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 41
General
CCF12HRNF
CCF12HRNF SilexConnect ® RF N Female Connector for 1/2” Coaxial Superflex
Cable
Type DINNF-1/2” H
Nominal size 1/2" in
Interface N Female
Body Style Straight
Mounting cable Model LCF12HR, HCAAY-50-09
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 42
General
CCF12HRNMA
CCF12HRNMA SilexConnect ® RF N Male Connector for 1/2” Coaxial Superflex
Cable
Type DINNMA-1/2”H
Nominal size 1/2" in
Interface N Male
Body Style Right angle
Mounting cable Model LCF12HR, HCAAY-50-09
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 43
General
CCF78STD716M
CCF78STD716M SilexConnect ® RF 7/16 Din Male Connector for 7/8” Coaxial
Cable
Type DINM-7/8”L
Nominal size 7/8" in
Interface 7/16 DIN Male
Body Style Straight
Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze/Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal Plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 44
General
CCF78STD716F
CCF78STD716F SilexConnect ® RF 7/16 Din Female Connector for 7/8” Coaxial Cable
Type DINF-7/8"L
Nominal size 7/8" in
Interface 7/16 DIN Female
Body Style Straight
Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze/Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal Plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 45
General
CCF78STD716MA
CCF78STD716MA SilexConnect ® RF7/16 Din Male Connector for 7/8” Coaxial
Cable
Type DINMA-7/8”L
Nominal size 7/8" in
Interface 7/16 DIN Male
Body Style Right angle
Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze/Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal Plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 46
General
CCF78STDNM
CCF78STDNM SilexConnect ® RF N Male Connector for 7/8” Coaxial Cable
Type DINNM-7/8”L
Nominal size 7/8" in
Interface N Male
Body Style Straight
Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 47
General
CCF78STDNF
CCF78STDNF SilexConnect ® RF N Female Connector for 7/8” Coaxial Cable
Type DINNF-7/8”L
Nominal size 7/8" in
Interface N Female
Body Style Straight
Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 48
General
CCF158STD716M
CCF158STD716M SilexConnect ® RF 7/16 Din Male Connector for 1-5/8”
Coaxial Cable
Type DINM-1-5/8”L
Nominal size 1-5/8" in
Interface 7/16 DIN Male
Body Style Straight
Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze/Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal Plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 49
General
CCF158STD716F
CCF158STD716F SilexConnect ® RF 7/16 Din Female Connector for 1-5/8”
Coaxial Cable
Type DINF-1-5/8"L
Nominal size 1-5/8" in
Interface 7/16 DIN Female
Body Style Straight
Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42
Technical Specifications
Characteristics DIN Type
Impedance 50 Ω
Operating Voltage 2700 V
Frequency Range ≤7.5 GHz
Shielding Effectiveness >115 dB
Inner Contact Resistance ≤0.4 MΩ
Outer Contact Resistance ≤0.2 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >10000 MΩ
Dielectric Withstanding Voltage 3000 V
Insertion Loss =0.08 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze/Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal Plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 50
General
CCF158STDNM
CCF158STDNM SilexConnect ® RF N Male Connector for 1-5/8” Coaxial Cable
Type DINNM-1-5/8”L
Nominal size 1-5/8" in
Interface N Male
Body Style Straight
Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 51
General
CCF58STDNF
CCF158STDNF SilexConnect ® RF N Female Connector for 1-5/8” Coaxial Cable
Type DINNF-1-5/8”L
Nominal size 1-5/8" in
Interface N Female
Body Style Straight
Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42
Technical Specifications
Characteristics N Type
Impedance 50 Ω
Operating Voltage 1500 V
Frequency Range ≤18.0 GHz
Shielding Effectiveness >115 Db
Inner Contact Resistance ≤0.8 MΩ
Outer Contact Resistance ≤0.25 MΩ
Intermodulation ≤-155 dBc
Insulation Resistance >5000 MΩ
Dielectric Withstanding Voltage 2500 V
Insertion Loss =0.1 dB
VSWR
0.8 ~ 1.0GHz ≤1.08
1.7 ~ 2.5GHz ≤1.10
Inner Conductor Pin Brass/Silver Plating
Inner Conductor Socket Tin Bronze /Silver Plating
Insulator PTFE or TPX
Body & Outer Conductor Brass/Trimetal plating
Gasket Silicon Rubber
Durability >500 cycle
Environmental Specifications
Temperature Range -65 ºC ~ +165ºC
Immersion Depth -
Immersion Test Method IEC 60529:2001, IP65
Moisture Resistance Test Method IEC 60068-2-3
Mechanical Shock Test Method IEC 60068-2-27
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6
Corrosion Test Method IEC 60068-2-11
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Página
| 52
General
GLQ14DINKK627T
Arrestors DINM–DINF 2700 Connector 7/16
Arrestors DINF–DINF 2700 Connector 7/16
Type DIN716
Surge arrestors are designed to protect wireless base stations, switching centers and
transmission lines from the damaging effects of extreme high voltage surges caused by lightning strikes.
We our lightning protection devices are designed and tested to the most demanding specifications.
Their rugged construction utilizes solid metal housing, and superior plating, which results in outstanding system protection and
operating continuity
• Superior IM performance for reliable long-term operation
• Excellent electrical performance, low VSWR, low insertion loss
• Waterproof to IP68
• Including grounding wire kit
• Totally maintenance free
Technical Specifications
Surge Arrestor Type Quarter Wave
Design 90° Stub
Coaxial Cable Type Foam Dielectric
Connector Interface 7-16 DIN
Frequency Range - MHz 690 - 2700
Minimum Return Loss, VSWR (dB) 690-2700 MHz: 1.19 (21)
Insertion Loss, dB (Max) 0.10
3rd Order IM Product @ 2x20 Watts, dBc < -160
Center Contact Connector A Brass, silver plated
Outer Contact Connector A Brass, white bronze
Center Contact Connector B Brass, silver plated
Outer Contact Connector B Brass, white bronze
Body Brass, white bronze
Dielectric PTFE
Gasket Silicone
Sealing class IP68
Operation Temperature, °C(°F) -45 to 85 (-49 to 185)
Mounting / Grounding Bulkhead; Thread for grounding M8
Drill Hole Size, mm (in) M8
Página
| 53
Tools Feeder Cutting
1/2" Standard Feeder Cutting Tool
Product Model: T-1/2"-EM
Body Material: Hard Aluminium Alloy
Match Cable: 1/2" Standard Feeder Cable
Cut Inner Conductor: 6.0~11.5mm
Stripper jacket: 15.0 & 20.0±1.0mm (Dual-Use)
Working Style: Electric Pistol Drill or Manual Operation
1/2" Superflex Feeder Cutting Tool
Product Model: TOL-1/2"SF-EM
Body Material: Hard Aluminium Alloy
Match Cable: 1/2" Standard Feeder Cable
Cut Inner Conductor: 6.0~11.5mm ***
Keep Dielectric: 2mm (Insulator Dielectric)
Stripper jacket: 20.0±1.0mm (Stripper jacket)
Working Style: Electric Pistol Drill or Manual Operation
1/2" Standard Feeder Cutting Tool
Item Name: 1/2" Standard Feeder Cutting Tool
Product Model: T-1/2-RS
1/2" Superflex Feeder Cutting Tool
Item Name: 1/2" Superflex Feeder Cutting Tool
Product Model: T-1/2SF-RS
7/8" Feeder Cutting Tool
Product Model: TOL-7/8-HXC
Body Material: PP Injection Molding
Match Cable: 7/8" Feeder Cable
Working Style: Manual Operation
Página
| 54
Página
| 55
Global Worldwide Distribution
Regulatory Compliance/Certifications
RoHS 2011/65/EU RoHS Compliant
Designed, manufactured and/or distributed under quality management system
Silex System Telecom
San Erasmo, 31 Nave 8
28021 - Madrid (Spain)
Tel.: + 34 915 05 67 76
Mobile: +34 619 332 634
E-Mail: info@silexst.com
Web: www.silexst.com
Certified Products: ISO / EN / IEC
Ordering No.
Info32543SLink/WERE/09-2014
pA 1SFSD34
© 09.2014 Silexst
Production & Powered By Silexst
All specifications are subject to change. See www.silexst.com for the most current information. Revised: September 06, 2014
Silex Global Spain, S.L. | The information contained in this document is accurate to the best of our knowledge and representative of the part described herein. It may be necessary
to make modifications to the part and/or the documentation of the part, in order to implement improvements. Silexst reserves the right to make such changes as required. Unless otherwise stated,
all specifications are nominal.
techsupport@silexst.com – www.silexst.com
©2014 Silexst All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of Silexst

More Related Content

What's hot

DFMA guidelines for PCB Design
DFMA guidelines for PCB DesignDFMA guidelines for PCB Design
DFMA guidelines for PCB DesignVihari Andukuri
 
Master low-voltage saudi cable co.
Master low-voltage saudi cable co.Master low-voltage saudi cable co.
Master low-voltage saudi cable co.Raymund Cortez
 
SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...
SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...
SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...Thorne & Derrick International
 
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands Thorne & Derrick International
 
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors Thorne & Derrick International
 
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...Thorne & Derrick International
 
product overview
product overview product overview
product overview KEILearning
 
Catalog from Zhengzhou Sanhe Cable
Catalog from Zhengzhou Sanhe Cable Catalog from Zhengzhou Sanhe Cable
Catalog from Zhengzhou Sanhe Cable Amy Wang
 
Rg58 vs lmr400
Rg58 vs lmr400Rg58 vs lmr400
Rg58 vs lmr400YilinWei6
 
Tai lieu tong quan antena
Tai lieu tong quan antenaTai lieu tong quan antena
Tai lieu tong quan antenaVan Kiem Nguyen
 
Gleam Electric & Power Company Ghaziabad, Electrical Power Cables & Wires
Gleam Electric & Power Company Ghaziabad, Electrical Power Cables & WiresGleam Electric & Power Company Ghaziabad, Electrical Power Cables & Wires
Gleam Electric & Power Company Ghaziabad, Electrical Power Cables & WiresIndiaMART InterMESH Limited
 
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...Thorne & Derrick International
 

What's hot (18)

ABB Kabeldon 145kV Dry Cable Termination - IEC 60840
ABB Kabeldon 145kV Dry Cable Termination - IEC 60840ABB Kabeldon 145kV Dry Cable Termination - IEC 60840
ABB Kabeldon 145kV Dry Cable Termination - IEC 60840
 
CMP CABLE GLANDS
CMP CABLE GLANDS CMP CABLE GLANDS
CMP CABLE GLANDS
 
DFMA guidelines for PCB Design
DFMA guidelines for PCB DesignDFMA guidelines for PCB Design
DFMA guidelines for PCB Design
 
Master low-voltage saudi cable co.
Master low-voltage saudi cable co.Master low-voltage saudi cable co.
Master low-voltage saudi cable co.
 
3M Heat Shrink Tubing & Sleeving
3M Heat Shrink Tubing & Sleeving3M Heat Shrink Tubing & Sleeving
3M Heat Shrink Tubing & Sleeving
 
SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...
SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...
SPS Low Voltage Live Pot End Kits - Heat Shrink Pot End Joints & Live Cable E...
 
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
 
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
Nexans Euromold Interface C 400 Symmetrical Series Cable Connectors
 
Prysmian BICC BICON Cable Glands - Catalogue
Prysmian BICC BICON Cable Glands - CataloguePrysmian BICC BICON Cable Glands - Catalogue
Prysmian BICC BICON Cable Glands - Catalogue
 
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
Craig and Derricott Isolators & Switch Disconnectors - Isolation Equipment an...
 
17.cabling system
17.cabling system17.cabling system
17.cabling system
 
product overview
product overview product overview
product overview
 
Catalog from Zhengzhou Sanhe Cable
Catalog from Zhengzhou Sanhe Cable Catalog from Zhengzhou Sanhe Cable
Catalog from Zhengzhou Sanhe Cable
 
Rg58 vs lmr400
Rg58 vs lmr400Rg58 vs lmr400
Rg58 vs lmr400
 
Tai lieu tong quan antena
Tai lieu tong quan antenaTai lieu tong quan antena
Tai lieu tong quan antena
 
Cable catalogue 2016
Cable catalogue 2016Cable catalogue 2016
Cable catalogue 2016
 
Gleam Electric & Power Company Ghaziabad, Electrical Power Cables & Wires
Gleam Electric & Power Company Ghaziabad, Electrical Power Cables & WiresGleam Electric & Power Company Ghaziabad, Electrical Power Cables & Wires
Gleam Electric & Power Company Ghaziabad, Electrical Power Cables & Wires
 
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
Nexans Euromold Connectors - 400LB Elbow, 400TB & 440TB Tee Connectors (Inter...
 

Similar to Catalogo Silex Cables RF50ohm y Conectores Coaxiales 50ohm

Draka - Mobile networks 10-2010 cable products kaapelituotteet
Draka - Mobile networks 10-2010 cable products kaapelituotteetDraka - Mobile networks 10-2010 cable products kaapelituotteet
Draka - Mobile networks 10-2010 cable products kaapelituotteetAerial Oy
 
Nexans Airfield Ground Lighting Cables (Primary Secondary)
Nexans Airfield Ground Lighting Cables (Primary  Secondary)Nexans Airfield Ground Lighting Cables (Primary  Secondary)
Nexans Airfield Ground Lighting Cables (Primary Secondary)Thorne & Derrick International
 
B3_Communications_Brochure
B3_Communications_BrochureB3_Communications_Brochure
B3_Communications_BrochureDonna M Sheridan
 
ELETRICAL WIRING, BRANDS, PRICE ,TYPES,
ELETRICAL WIRING, BRANDS, PRICE ,TYPES, ELETRICAL WIRING, BRANDS, PRICE ,TYPES,
ELETRICAL WIRING, BRANDS, PRICE ,TYPES, ShivaniAnand15
 
PV Solar Farm Power Cables - General Cable Harmohny LV Power Cables
PV Solar Farm Power Cables - General Cable Harmohny LV Power CablesPV Solar Farm Power Cables - General Cable Harmohny LV Power Cables
PV Solar Farm Power Cables - General Cable Harmohny LV Power CablesThorne & Derrick International
 
Nexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmm
Nexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmmNexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmm
Nexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmmThorne & Derrick International
 
Introduction cable engineering
Introduction cable engineeringIntroduction cable engineering
Introduction cable engineeringDaniel García
 
Nexans Euromold Connectors 400 Series Interface B Cable Connectors HV
Nexans Euromold Connectors 400 Series Interface B Cable Connectors HVNexans Euromold Connectors 400 Series Interface B Cable Connectors HV
Nexans Euromold Connectors 400 Series Interface B Cable Connectors HVThorne & Derrick International
 
Nexans Euromold Interface A 200 Series Screened Cable Connectors
Nexans Euromold Interface A 200 Series Screened Cable Connectors Nexans Euromold Interface A 200 Series Screened Cable Connectors
Nexans Euromold Interface A 200 Series Screened Cable Connectors Thorne & Derrick International
 
Nexans Euromold MV Separable Connectors & Bushings - Interface A
Nexans Euromold MV Separable Connectors & Bushings - Interface ANexans Euromold MV Separable Connectors & Bushings - Interface A
Nexans Euromold MV Separable Connectors & Bushings - Interface AThorne & Derrick International
 
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...Thorne & Derrick International
 
Datwyler universal safety fire fiber cabel info tech middle east
Datwyler universal safety fire fiber cabel   info tech middle eastDatwyler universal safety fire fiber cabel   info tech middle east
Datwyler universal safety fire fiber cabel info tech middle eastAli Shoaee
 
DataSheet Rg58
DataSheet Rg58DataSheet Rg58
DataSheet Rg58Hola Hola
 
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmmNexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmmThorne & Derrick International
 
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmmNexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmmThorne & Derrick International
 
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)Thorne & Derrick International
 
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmmNexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmmThorne & Derrick International
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaThorne & Derrick International
 
CABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUES
CABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUESCABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUES
CABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUESEMERSON EDUARDO RODRIGUES
 

Similar to Catalogo Silex Cables RF50ohm y Conectores Coaxiales 50ohm (20)

Draka - Mobile networks 10-2010 cable products kaapelituotteet
Draka - Mobile networks 10-2010 cable products kaapelituotteetDraka - Mobile networks 10-2010 cable products kaapelituotteet
Draka - Mobile networks 10-2010 cable products kaapelituotteet
 
Nexans Airfield Ground Lighting Cables (Primary Secondary)
Nexans Airfield Ground Lighting Cables (Primary  Secondary)Nexans Airfield Ground Lighting Cables (Primary  Secondary)
Nexans Airfield Ground Lighting Cables (Primary Secondary)
 
B3_Communications_Brochure
B3_Communications_BrochureB3_Communications_Brochure
B3_Communications_Brochure
 
ELETRICAL WIRING, BRANDS, PRICE ,TYPES,
ELETRICAL WIRING, BRANDS, PRICE ,TYPES, ELETRICAL WIRING, BRANDS, PRICE ,TYPES,
ELETRICAL WIRING, BRANDS, PRICE ,TYPES,
 
PV Solar Farm Power Cables - General Cable Harmohny LV Power Cables
PV Solar Farm Power Cables - General Cable Harmohny LV Power CablesPV Solar Farm Power Cables - General Cable Harmohny LV Power Cables
PV Solar Farm Power Cables - General Cable Harmohny LV Power Cables
 
Nexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmm
Nexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmmNexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmm
Nexans Euromold 158LR HV Elbow Connectors 12kV 250Amp 70-95sqmm
 
Introduction cable engineering
Introduction cable engineeringIntroduction cable engineering
Introduction cable engineering
 
Nexans Euromold Connectors 400 Series Interface B Cable Connectors HV
Nexans Euromold Connectors 400 Series Interface B Cable Connectors HVNexans Euromold Connectors 400 Series Interface B Cable Connectors HV
Nexans Euromold Connectors 400 Series Interface B Cable Connectors HV
 
Nexans Euromold Interface A 200 Series Screened Cable Connectors
Nexans Euromold Interface A 200 Series Screened Cable Connectors Nexans Euromold Interface A 200 Series Screened Cable Connectors
Nexans Euromold Interface A 200 Series Screened Cable Connectors
 
Nexans Euromold MV Separable Connectors & Bushings - Interface A
Nexans Euromold MV Separable Connectors & Bushings - Interface ANexans Euromold MV Separable Connectors & Bushings - Interface A
Nexans Euromold MV Separable Connectors & Bushings - Interface A
 
Cable Course.pptx
Cable Course.pptxCable Course.pptx
Cable Course.pptx
 
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
Nexans Euromold Connectors 400 Series Interface C Symmetrical Cable Connector...
 
Datwyler universal safety fire fiber cabel info tech middle east
Datwyler universal safety fire fiber cabel   info tech middle eastDatwyler universal safety fire fiber cabel   info tech middle east
Datwyler universal safety fire fiber cabel info tech middle east
 
DataSheet Rg58
DataSheet Rg58DataSheet Rg58
DataSheet Rg58
 
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmmNexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
 
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmmNexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
 
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
 
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmmNexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
 
CABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUES
CABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUESCABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUES
CABLE DISTRIBUTION PANEL EMERSON EDUARDO RODRIGUES
 

Recently uploaded

Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...Neo4j
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...gurkirankumar98700
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEarley Information Science
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Paola De la Torre
 

Recently uploaded (20)

Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101
 

Catalogo Silex Cables RF50ohm y Conectores Coaxiales 50ohm

  • 2. Página | 2 Table of Contents: Coaxial Cable Series Coaxial RF 50 Cupper and Aluminum Cooper – Pag.5 Aluminum – Pag.13 Jumpers – Pag.19 Jumpers Low PIM Grounding Kits–Pag.23 Arrestors – Pag. 52 Clamps – Pag.24 Tools – Pag. 53 Connect 1/2"–Pag.31 Superflex 1/2"–Pag.37 Connect 7/8"–Pag.43 Connect 1-5/8"–Pag.48
  • 4. Página | 4 Coaxial Cable - Comparison of different cable types The product range includes high- frequency coaxial connectors and cables, RF- test & measurement products, as well as infrastructure site solutions, connectors, cables or accessories for radio base stations. Image Overview Type Section Inner conductor Outer conductor Jacket options Order number Superflexible Cables SilexFlex 1/4" Copper-Clad Aluminum Wire Corrugated Copper Tube PE LCF14HR HL-FR-Z LCF14HRZ 3/8" Copper-Clad Aluminum Wire Corrugated Copper Tube PE LCF38HR HL-FR-Z LCF38HRZ 1/2" Copper-Clad Aluminum Wire Corrugated Copper Tube PE LCF12HR HL-FR-Z LCF12HRZ Flexible Cooper Cables SilexStd 1/4" Copper-Clad Aluminum Wire Corrugated Copper Tube PE LCF14STD HL-FR-Z LCF14STDZ 3/8" Copper-Clad Aluminum Wire Corrugated Copper Tube PE LCF38STD HL-FR-Z LCF38STDZ 1/2" Copper-Clad Aluminum Wire Corrugated Copper Tube PE LCF12STD HL-FR-Z LCF12STDZ 5/8" Smooth Copper Tube Corrugated Copper Tube PE LCF58STD HL-FR-Z LCF58STDZ 7/8" Smooth Copper Tube Corrugated Copper Tube PE LCF78STD HL-FR-Z LCF78STDZ 1-1/4" Smooth Copper Tube Corrugated Copper Tube PE LCF114STD HL-FR-Z LCF114STDZ 1-5/8" Helical Copper Tube Corrugated Copper Tube PE LCF158STD HL-FR-Z LCF158STDZ 2-1/4" Helical Copper Tube Corrugated Copper Tube PE LCF214STD HL-FR-Z LCF214STDZ Flexible Aluminum Cables SilexStl 1/2" Copper-Clad Aluminum Wire Corrugated Aluminium Tube PE LCF12STL HL-FR-Z LCF12STLZ 7/8" Smooth Copper Tube Corrugated Aluminium Tube PE LCF78STL HL-FR-Z LCF78STLZ 1-1/4" Smooth Copper Tube Corrugated Aluminium Tube PE LCF114STL HL-FR-Z LCF114STLZ 1-5/8" Helical Copper Tube Corrugated Aluminium Tube PE LCF158STL HL-FR-Z LCF158STLZ Jacket: PE Standard Polyethylene, PE, Metalhydroxite Filling, UV resistant PE jacket, halogen free according to IEC 60754 Jacket: HL-FR-Z Halogen Free & Fire resistant (Z) Test on flammability of single cables Test in accordance with: IEC 60332-1-2 EN 60332-1-2 Test on flammability of cable bundles Test in accordance with: IEC 60332-3 Cat. C EN 50266-2-4 Cat. C Test on smoke density Test in accordance with: IEC 61034-1 and -2 EN 61034-1 and -2 Test on corrosive gas emissions Test in accordance with: IEC 60754-2 EN 50267-2-2 Test on insulation integrity Test in accordance with: IEC 60331-23 VDE 0472 Part 814
  • 5. Página | 5 General LCF12STD(Z) LCF12STD(Z), Silexstd ® RF Low Density Foam Coaxial Cable 1/2", corrugated copper, 1/2 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z). Type HCAAY(Z)-50-12 Construction Materials Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Copper Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 4.80 mm Dielectric Diameter 12.30 mm Outer Conductor Diameter 13.80 mm Diameter Over Jacket 15.70 mm Mechanical Specifications Minimum Bending Radius Single Bending 50 mm Repeated Bending 125 mm Minimum Number of Bends 15 Tensile Strength 1100 N (247 lb) Electrical Specifications Capacitance 76.0 pF/m (23.2 pF/ft) Impedance 50 ± 1 O Velocity 88% RF Peak Voltage 1.60 kV Peak Power Rating 40 kW Cut-o" Frequency 18.8 GHz Shielding E"ectiveness>10MHz >120 dB Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 6. Página | 6 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100,00 3,42 1,04 2,23 150,00 4,22 1,29 1,81 200,00 4,90 1,49 1,56 280,00 6,00 1,83 1,27 450,00 7,50 2,29 1,02 800,00 10,20 3,11 0,75 900,00 10,90 3,32 0,71 1000,00 11,60 3,54 0,67 1500,00 14,40 4,39 0,53 1800,00 16,00 4,88 0,48 2000,00 17,00 5,18 0,46 2200,00 17,90 5,46 0,43 2400,00 18,70 5,70 0,42 2500,00 19,30 5,88 0,41 3000,00 21,30 6,49 0,37 Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value.
  • 7. Página | 7 General LCF12HR(Z) LCF12HR(Z), Silexflex ® RF SuperFlexible Foam Coaxial Cable 1/2", corrugated copper, 1/2 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z). Type HRCAY(Z)-50-9 Construction Materials Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Copper Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 3.60 mm Dielectric Diameter 8.70 mm Outer Conductor Diameter 12.00 mm Diameter Over Jacket 13.30 mm Mechanical Specifications Minimum Bending Radius Single Bending 15 mm Repeated Bending 30 mm Minimum Number of Bends 15 Tensile Strength 650 N (143 lb) Electrical Specifications Capacitance 80.0 pF/m (24.4 pF/ft) Impedance 50 ± 1 Ω Velocity 83% RF Peak Voltage 1.13 kV Peak Power Rating 19 kW Cut-off Frequency 12.50 GHz Shielding Effectiveness>10MHz >120 Db Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 8. Página | 8 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100,00 3,22 0,98 3,03 150,00 4,05 1,23 2,39 200,00 4,65 1,42 2,11 280,00 5,65 1,72 1,69 450,00 7,20 2,19 1,37 800,00 9,86 3,01 1,00 900,00 10,56 3,22 0,94 1000,00 11,15 3,40 0,88 1500,00 13,80 4,21 0,70 1800,00 15,55 4,74 0,63 2000,00 16,40 5,00 0,59 2200,00 17,35 5,29 0,56 2400,00 18,10 5,52 0,53 2500,00 18,50 5,64 0,52 3000,00 20,90 6,37 0,48 Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value .
  • 9. Página | 9 General LCF78STD(Z) LCF78STD(Z), Silexstd ® RF Low Density Foam Coaxial Cable 7/8”, corrugated copper, 7/8 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z). Type HCTAY (Z)-50-22 Construction Materials Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Copper Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 9.00 mm Dielectric Diameter 22.30 mm Outer Conductor Diameter 24.90 mm Diameter Over Jacket 27.50 mm Mechanical Specifications Minimum Bending Radius Single Bending 90 mm Repeated Bending 250 mm Minimum Number of Bends 15 Tensile Strength 1470 N (330 lb) Electrical Specifications Capacitance 75.0 pF/m (22.9 pF/ft) Impedance 50 ± 1 Ω Velocity 89% RF Peak Voltage 3.00 kV Peak Power Rating 91 kW Cut-off Frequency 5.20 GHz Shielding Effectiveness>10MHz >120 dB Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 10. Página | 10 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100,00 1,19 0,36 8,62 150,00 1,47 0,45 7,20 200,00 1,71 0,52 5,99 280,00 2,05 0,62 4,94 450,00 2,64 0,80 3,88 800,00 3,62 1,10 2,83 900,00 3,87 1,18 2,65 1000,00 4,10 1,25 2,50 1500,00 5,16 1,57 1,99 1800,00 5,73 1,75 1,79 2000,00 6,09 1,86 1,68 2200,00 6,44 1,96 1,59 2400,00 6,78 2,07 1,54 2500,00 6,95 2,12 1,50 3000,00 7,74 2,36 1,33 Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value.
  • 11. Página | 11 General LCF158STD(Z) LCF158STD(Z), Silexstd ® RF Low Density Foam Coaxial Cable 1-5/8", corrugated copper, 1-5/8 in, Black PE or Low Smoke Halogen-free Fire- retardant (Z). Type HHTAY(Z)-50-42 Construction Materials Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Copper Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 17.40 mm Dielectric Diameter 42.80 mm Outer Conductor Diameter 46.50 mm Diameter Over Jacket 49.50 mm Mechanical Specifications Minimum Bending Radius Single Bending 200 mm Repeated Bending 510 mm Minimum Number of Bends 15 Tensile Strength 3300 N (750 lb) Electrical Specifications Capacitance 76.0 pF/m (23.2 pF/ft) Impedance 50 ± 1 Ω Velocity 88% RF Peak Voltage 5.70 kV Peak Power Rating 320 kW Cut-off Frequency 2.80 GHz Shielding Effectiveness>10MHz >120 dB Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 12. Página | 12 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100,00 0,67 0,20 16,90 150,00 0,84 0,26 13,48 200,00 0,98 0,30 11,60 280,00 1,20 0,37 9,47 450,00 1,53 0,47 7,36 800,00 2,12 0,65 5,26 900,00 2,28 0,69 4,93 1000,00 2,42 0,74 4,61 1500,00 3,09 0,94 3,64 1800,00 3,45 1,05 3,27 2000,00 3,68 1,12 3,00 2200,00 3,91 1,19 2,85 2400,00 4,13 1,26 2,70 2500,00 4,24 1,29 2,61 Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value.
  • 13. Página | 13 General LCF12STL(Z) LCF12STL(Z), Silexstl ® RF Low Density Foam Coaxial Cable 1/2", corrugated Aluminium, 1/2 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z). Type HCAAY-L(Z)-50-12 Construction Materials Inner Conductor Copper-Clad Aluminum Wire Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Aluminium Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 4.80 mm Dielectric Diameter 12.30 mm Outer Conductor Diameter 13.80 mm Diameter Over Jacket 15.70 mm Mechanical Specifications Minimum Bending Radius Single Bending 50 mm Repeated Bending 125 mm Minimum Number of Bends 15 Tensile Strength 1000 N Electrical Specifications Capacitance 76.0 pF/m (23.2 pF/ft) Impedance 50 ± 1 O Velocity 88% RF Peak Voltage 1.60 kV Peak Power Rating 36 kW Cut-o" Frequency 8.8 GHz Shielding E"ectiveness>10MHz >120 dB Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 14. Página | 14 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100,00 2.40 (0.73) 3,58 200,00 3.45 (1.05) 2,50 450,00 5.25 (1.60) 1,64 800,00 7.15 (2.18) 1,21 900,00 7.65 (2.33) 1,14 1000,00 8.10 (2.47) 1,07 1500,00 10.10 (3.08) 0,86 1800,00 11.15 (3.40) 0,78 2000,00 11.85 (3.61) 0,74 2200,00 12.50 (3.81) 0,70 2400,00 13.05 (3.98) 0,68 2500,00 13.40 (4.08) 0,66 3000,00 14.80 (4.51) 0,59 Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value.
  • 15. Página | 15 General LCF78STL(Z) LCF78STL(Z), Silexstl ® RF Low Density Foam Coaxial Cable 7/8", corrugated Aluminium, 7/8 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z). Type HCTAY-L (Z)-50-22 Construction Materials Inner Conductor Smooth Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Aluminium Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 9.00 mm Dielectric Diameter 22.30 mm Outer Conductor Diameter 24.90 mm Diameter Over Jacket 27.50 mm Mechanical Specifications Minimum Bending Radius Single Bending 130 mm Repeated Bending 250 mm Minimum Number of Bends 15 Tensile Strength 1350 N Electrical Specifications Capacitance 75 pF/m(22.9 pF/ft) Impedance 50 ± 1 Ω Velocity 88% RF Peak Voltage 3.00 kV Peak Power Rating 82 kW Cut-off Frequency 5.20 GHz Shielding Effectiveness>10MHz >120 dB Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 16. Página | 16 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100 MHz 1.25 (0.38) 6,50 200 MHz 1.80 (0.55) 4,50 450 MHz 2.77 (0.84) 3,00 800 MHz 3.83 (1.17) 2,20 900 MHz 4.08 (1.24) 2,10 1000 MHz 4.30 (1.31) 2,00 1500 MHz 5.45 (1.66) 1,70 1800 MHz 6.05 (1.84) 1,60 2000 MHz 6.45 (1.97) 1,50 2200 MHz 6.85 (2.09) 1,40 2400 MHz 7.15 (2.18) 1,30 2500 MHz 7.35 (2.24) 1,20 3000 MHz 8.20 (2.50) 1,10 Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value.
  • 17. Página | 17 General LCF158STL(Z) LCF158STL(Z), Silexstl ® RF Coaxial Cable 1-5/8", corrugated Aluminium, 1-5/8 in, Black PE or Low Smoke Halogen-free Fire-retardant (Z). Type HHTAY-L (Z)-50-42 Construction Materials Inner Conductor Helical Copper Tube Dielectric Physical Foam Polyethylene Outer Conductor Corrugated Aluminum Tube Jacket Black PE or Low Smoke Halogen-free Fire-retardant Physical Dimensions Inner Conductor Diameter 17.40 mm Dielectric Diameter 42.80 mm Outer Conductor Diameter 46.50 mm Diameter Over Jacket 49.50 mm Mechanical Specifications Minimum Bending Radius Single Bending 200 mm Repeated Bending 510 mm Minimum Number of Bends 15 Tensile Strength 3000 N Electrical Specifications Capacitance 76.0 pF/m (23.2 pF/ft) Impedance 50 ± 1 Ω Velocity 88% RF Peak Voltage 5.70 kV Peak Power Rating 290 kW Cut-off Frequency 2.80 GHz Shielding Effectiveness>10MHz >120 dB Insulation resistance 5000M Ω-Km VSWR 0.8~1.0 GHz ≤1.10 1.7~2.2 GHz ≤1.10 2.2~2.7 GHz ≤1.13
  • 18. Página | 18 Environmental Specifications Storage Temperature -55 ˚C ~ +85 ˚C Installation Temperature -40 ˚C ~ +60 ˚C Operation Temperature -55 ˚C ~ +85 ˚C Perforance - Attenuation Frequency Attenuation Attenuation Average MHz dB/100 m dB/100 ft Power Rating (kW) 100 MHz 0.76 (0.23) 15,55 200 MHz 1.09 (0.33) 10,27 450 MHz 1.72 (0.52) 6,46 800 MHz 2.40 (0.73) 4,62 900 MHz 2.58 (0.79) 4,30 1000 MHz 2.74 (0.84) 4,05 1500 MHz 3.50 (1.07) 3,17 1800 MHz 3.94 (1.20) 2,83 2000 MHz 4.20 (1.28) 2,65 2200 MHz 4.46 (1.36) 2,49 2400 MHz 4.74 (1.44) 2,34 2500 MHz 4.86 (1.48) 2,28 3000 MHz - - Standard Conditions For Attenuation: VSWR 1.0, Cable temperature 20 °C (68 °F) For Average Power: VSWR 1.0, Ambient temperature 40 °C (104 °F) Inner Conductor temperature 100 °C (212 °F). No solar loading. Maximum attenuation value shall be 105% of the nominal attenuation value.
  • 19. Página | 19 General Specifications LCF12STD-xxM-DINF-DINF Low PIM |-160 dBc Jumper 1/2" Standard type LCFSTD Silexjpx ® Jumper with interface types 7/16 DIN Female straight to 7/16 DIN Female Low PIM, (xx) Length Jumpers feature specially designed connectors which are soldered-on in a strictly controlled industrial process. The connector design and manufacturing process has been optimized to produce premium PIM3, VSWR and IM levels. The low PIM coaxial jumper cable assemblies have an injection molded boot on each connector which provides added strain relief and weather sealing ensuring long term durability. Available in 1/2" flexible and 1/2" superflexible coaxial cables, Silexjpx low PIM coax cables can be ordered in standard and custom lengths with 7/16 DIN and Type N connectors to meet your specific requirements. Cable assembly Series connector 1 7/16 Interface 1 jack straight female Cable, Nominal Size 1/2〃Standard LCF Type Series connector 2 7/16 Interface 2 jack straight female Outline Drawing Construction Materials Cable Type 1/2" LCF Jacket PE or (Z) Fire Retardancy Test Method IEC 60332-1 flame retardant | IEC 60332-3C-24 fire retardant Smoke Index Test Method IEC 61034 low smoke Toxicity Index Test Method IEC 60754-1 | IEC 60754-2 smoke emission: halogen free, non corrosive Connector 1 7/16 DIN Female straight Connector 1 7/16 DIN Female straight Specifications Connector Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Sealing class IP68
  • 20. Página | 20 Electrical Specifications Frequency Range DC to 3 GHz Impedance Ohms 50 Ω Maximum VSWR 1.15:1 Velocity Propagation 83% RFShielding 120 dB PeakPower 16 KWatts Passive Intermodulation -160 dBc VSWR (Return Loss, dB) 1.065 (30) @ 1710 - 1990 MHz 1.065 (30) @ 2000 - 2200 MHz 1.083 (28) @ 2200 - 2700 MHz Environmental Specifications Installation Temperature, °C(°F) -25 to 60 (-13 to 140 ) Operation Temperature, °C(°F) -50 to 85 (-58 to 185 ) Storage Temperature, °C(°F) -70 to 85 (-94 to 185 ) Jumper Assembly Sample Example Order Number: LCF12STD4M DINMA DINM Cable Types Length in Inches Connector 1 - Connector 2 = LCF12STD 4M DINMA DINM Type Connector LCF12STD M DIN Male DINM HCF12STD M DIN Female DINF LMR240 M DIN Male Right Angle DINMA LMR300 M N Male NM LMR400 M N Female NF RG8 M N Male Right Angle NMA Connector 1:DIN Male Right Angle RG59 M Connector 1: DIN Male 7/16 RG213 M Length: 4 metres RG214 M Cable Type: LCF12STD
  • 21. Página | 21 General Specifications LCF12HR-xxM-DINMA-DINM Low PIM |-160 dBc Jumper 1/2" Standard type LCFSTD Silexjpx ® Jumper with interface types 7/16 DIN Male right angle to 7/16 DIN Male straight Low PIM, (xx) Length Jumpers feature specially designed connectors which are soldered-on in a strictly controlled industrial process. The connector design and manufacturing process has been optimized to produce premium PIM3, VSWR and IM levels. The low PIM coaxial jumper cable assemblies have an injection molded boot on each connector which provides added strain relief and weather sealing ensuring long term durability. Available in 1/2" flexible and 1/2" superflexible coaxial cables, Silexjpx low PIM coax cables can be ordered in standard and custom lengths with 7/16 DIN and Type N connectors to meet your specific requirements. Cable assembly Series connector 1 7/16 Interface 1 jack right angle Cable, Nominal Size 1/2〃Superflex HR Type Series connector 2 7/16 Interface 2 jack straight Jumper Assembly Sample Example Order Number: LCF12STD4M DINMA DINM Cable Types Length in Inches Connector 1 - Connector 2 = LCF12STD 4M DINMA DINM Type Connector LCF12STD M DIN Male DINM HCF12STD M DIN Female DINF LMR240 M DIN Male Right Angle DINMA LMR300 M N Male NM LMR400 M N Female NF RG8 M N Male Right Angle NMA Connector 1:DIN Male Right Angle RG59 M Connector 1: DIN Male 7/16 RG213 M Length: 4 metres RG214 M Cable Type: LCF12STD
  • 22. Página | 22 Outline Drawing Construction Materials Cable Type 1/2" LCF Jacket PE or (Z) Fire Retardancy Test Method IEC 60332-1 flame retardant | IEC 60332-3C-24 fire retardant Smoke Index Test Method IEC 61034 low smoke Toxicity Index Test Method IEC 60754-1 | IEC 60754-2 smoke emission: halogen free, non corrosive Connector 1 7/16 DIN Male right angle Connector 1 7/16 DIN Male straigth Specifications Connector Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Sealing class IP68 Electrical Specifications Frequency Range DC to 2.7 GHz Impedance Ohms 50 Ω Maximum VSWR 1.11:1 Velocity Propagation 83% RFShielding 120 dB PeakPower 16 KWatts Passive Intermodulation -160 dBc VSWR (Return Loss, dB) 1.065 (30) @ 1710 - 1990 MHz 1.065 (30) @ 2000 - 2200 MHz 1.083 (28) @ 2200 - 2700 MHz Environmental Specifications Installation Temperature, °C(°F) -25 to 60 (-13 to 140 ) Operation Temperature, °C(°F) -50 to 85 (-58 to 185 ) Storage Temperature, °C(°F) -70 to 85 (-94 to 185 )
  • 23. Página | 23 General Specifications GROUNDING KITS SLXGKM 3/8", 1/2", 7/8", 1-5/8 This Grounding Kit has been developed for copper and aluminum cable series. The Grounding Kit body facilitates a proper attachment to the coaxial cable, ensuring that the performance of the coaxial cable. The tin plated copper mesh provides a secure, low resistance contact to the cable outer conductor. The installation is fast and simple. Electrical Specifications Item SLXGKM Type Grounding Wire Length 1 m or Customized Cable Section Acreage 16/25 mm2 Electric Pressure >500 N Contact Material Tinned Copper Wire Braiding Waterproof Material - Resistance ≤3 mΩ Voltage Resistance 80 kA Power Frequency Withstand Voltage 35 kV Insulation Resistance 10 GΩ Earth Resistance 2 mΩ Durability >10 years Suitable Cable 3/8", 1/2", 7/8", 1-5/8
  • 24. Página | 24 General Specifications FEEDER CLAMPS SLXCL Through Type Feeder Clamp Stainless steel clamps are applicable to fix feeder cables for microwave and mobile communication; they are made up of excellent anti-acid steel, will never rust under weather conditions. Parts Specifications Materials C-clamp 5mm SUS304 Towl washer 1mm SUS304 Bolt M8*45 SUS304 Nut Ø8 SUS304 Threaded rod M8*80 SUS304 Plastic clamp 1/2", 7/8'', 1-5/8” PP Nut Ø8 SUS304 Flat washer Ø8 SUS304 Outdoor clamp for 1/2" Tower CLE Feeder Clamp SXCL121E SXCL122E SXCL123E SXCL124E
  • 25. Página | 25 Outdoor clamp for 7/8" Tower CLE Feeder Clamp SXCL781E SXCL782E SXCL783E SXCL784E SXCL781E2 SXCL783E2 SXCL783E2 Outdoor clamp for 1 5/8" Tower CLE Feeder Clamp SXCL1581E SXCL1582E SXCL1583E
  • 26. Página | 26 Outdoor clamp for 1 5/8" Tower CLE Feeder Clamp SXCL1581E2 SXCL1583E2 SXCL1583E2 Outdoor clamp for 3/8, RG8, RG214 Tower CLE Feeder Clamp SXCL381E2 SXCL382E2 SXCL383E2 SXCLRG81E2 SXCLRG82E2 SXCLRG83E2 SXCLRG2141E2 SXCLRG2142E2 SXCLRG2143E2 Outdoor clamp for UTP cable 2x7 or 2x11 Tower CLE Feeder Clamp SXCLUTP271E2 SXCLUTP272E2 SXCLUTP273E2 SXCLUTP2111E2 SXCLUTP2112E2 SXCLUTP2113E2
  • 27. Página | 27 Outdoor clamp for FO + DC Tower CLE Feeder Clamp SXCLFO589131E2 SXCLFO589132E2 SXCLFO589133E2 Outdoor for Tower Through Clamp Hanger Kit
  • 28. Página | 28 Indoor CLE Feeder Clamp for 1/2", FO, UTP, RG cables types singles and doubles Fixings example on steel wire-mesh cable trays SXCL121I SXCL122I SXCL123I SXCL781I SXCL782I SXCL783I SXCL1581I SXCL1582I SXCL1583I SXCLFO55141I SXCLFO55142I SXCLFO55143I SXCLFO589131I2 SXCLFO589132I2 SXCLFO589133I2
  • 29. Página | 29 Connector & Cable - Comparison of different connector types Size (1/4") (3/8") (1/2") (5/8") ( 7/8") (1-1/4") (1-5/8") SilexStdConnectorCableStandardFlex Coaxial Cable Standard Code HCAAY-50-6 HCAAY-50-8 HCAAY-50-12 HCTAY-50-16 HCTAY-50-22 HCTAY-50-32 HHTAY-50-42 Silex Code LCF14STD LCF38STD LCF12STD LCF58STD LCF78STD LCF114STD LCF158STD Connector Standard Code DINM-1/4"L DINM-3/8"L DINM-1/2"L DINM-5/8"L DINM-7/8"L DINM-1-1/4"L DINM-1-5/8"L Silex Code CCF14STD716M CCF38STD716M CCF12STD716M CCF58STD716M CCF78STD716M CCF114STD716M CCF158STD716M Connector Standard Code DINF-1/4"L DINF-3/8"L DINF-1/2"L DINF-5/8"L DINF-7/8"L DINF-1-1/4"L DINF-1-5/8"L Silex Code CCF14STD716F CCF38STD716F CCF12STD716F CCF58STD716F CCF78STD716F CCF114STD716F CCF158STD716F Connector Standard Code DINMA-1/4"L DINMA-3/8"L DINMA-1/2"L - DINMA-7/8"L - - Silex Code CCF14STD716MA CCF38STD716MA CCF12STD716MA - CCF12STD716MA - - Connector Standard Code NM-1/4"L NM-3/8"L NM-1/2"L NM-5/8"L NM-7/8"L NM-1-1/4"L NM-1-5/8"L Silex Code CCF14STDNM CCF38STDNM CCF12STDNM CCF58STDNM CCF78STDNM CCF114STDNM CCF158STDNM Connector Standard Code NF-1/4"L NF-3/8"L NF-1/2"L NF-5/8"L NF-7/8"L NF-1-1/4"L NF-1-5/8"L Silex Code CCF14STDNF CCF38STDNF CCF12STDNF CCF58STDNF CCF78STDNF CCF114STDNF CCF158STDNF Connector Standard Code NMA-1/4"L NMA-3/8"L NMA-1/2"L - - - - Silex Code CCF14STDNMA CCF38STDNMA CCF12STDNMA - - - - Size (1/4") (3/8") (1/2") (5/8") ( 7/8") (1-1/4") (1-5/8") SilexFlexConnectorCableSuperflex Coaxial Cable Standard Code HRCAY-50-5 HRCAY-50-7 HRCAY-50-9 Silex Code LCF14HR LCF38HR LCF12HR Connector Standard Code DINM-1/4"H DINM-3/8"H DINM-1/2"H Silex Code CCF14STDNM CCF38STDNM CCF12STDNM Connector Standard Code DINF-1/4"H DINF-3/8"H DINF-1/2"H Silex Code CCF14STDNF CCF38STDNF CCF12STDNF Connector Standard Code DINMA-1/4"H DINMA-3/8"H DINMA-1/2"H Silex Code CCF14STDNMA CCF38STDNMA CCF12STDNMA Connector Standard Code NM-1/4"H NM-3/8"H NM-1/2"H Silex Code CCF14HRNM CCF38HRNM CCF12HRNM Connector Standard Code NF-1/4"H NF-3/8"H NF-1/2"H Silex Code CCF14HRNF CCF38HRNF CCF12HRNF Connector Standard Code NMA-1/4"H NMA-3/8"H NMA-1/2"H Silex Code CCF14HRNMA CCF38HRNMA CCF12HRNMA
  • 30. Página | 30 Connector 7/16 & N Types SilexConnector offers a variety of connector types for Sliex Cablex Coaxial. Silexst® connectors are engineered and manufactured to the highest standards, achieving maximum performance. Silexst® connectors are available in both the male and female versions of type N and type 7/16 DIN connectors. Can be installed on coaxial cable quickly, easily and consistently. Precision Products for Demanding Applications SilexConnect™ high performance connectors are designed for use with both Silexstd® corrugated copper and Silexstl® corrugated aluminum cables. They are designed specifically to provide the highest quality connector-cable interface while simplifying and speeding up connector attachment. Advantages of Silexst® Connectors & Adaptors • Ease of Installation • Completely Weatherproof and Consistent • Long Life • Low Intermodulation and VSWR • Corrosion Resistant • Silver-plated bodies and silver-plated electrical • Low PIM
  • 31. Página | 31 General CCF12STD716M CCF12STD716M SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial Cable Type DINM-1/2"L Nominal size 1/2" in Interface 7/16 DIN Male Body Style Straight Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss ≤0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze/Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal Plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 32. Página | 32 General CCF12STD716F CCF12STD716F SilexConnect ® RF 7/16 Din Female Connector for 1/2” Coaxial Cable Type DINF-1/2"L Nominal size 1/2" in Interface 7/16 DIN Female Body Style Straight Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 33. Página | 33 General CCF12STD716MA CCF12STD716MA SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial Cable Type DINMA-1/2”L Nominal size 1/2" in Interface 7/16 DIN Male Body Style Right angle Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 34. Página | 34 General CCF12STDNM CCF12STDNM SilexConnect ® RF N Male Connector for 1/2” Coaxial Cable Type DINNM-1/2”L Nominal size 1/2" in Interface N Male Body Style Straight Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F Outline Drawing
  • 35. Página | 35 General CCF12STDNF CCF12STDNF SilexConnect ® RF N Female Connector for 1/2” Coaxial Cable Type DINNF-1/2” L Nominal size 1/2" in Interface N Female Body Style Straight Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 36. Página | 36 General CCF12STDNMA CCF12STD716NMA SilexConnect ® RF N Male Connector for 1/2” Coaxial Cable Type DINNMA-1/2”L Nominal size 1/2" in Interface N Male Body Style Right angle Mounting cable Models: copper LCF12STD, aluminum LCF12STL, HCAAY-50-12 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 37. Página | 37 General CCF12HR716M CCF12HR716M SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial Superflex Cable Type DINM-1/2"H Nominal size 1/2" in Interface 7/16 DIN Male Body Style Straight Mounting cable Model LCF12HR, HCAAY-50-09 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 38. Página | 38 General CCF12HR716F CCF12HR716F SilexConnect ® RF 7/16 Din Female Connector for 1/2” Coaxial Superflex Cable Type DINF-1/2"H Nominal size 1/2" in Interface 7/16 DIN Female Body Style Straight Mounting cable Model LCF12HR, HCAAY-50-09 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 39. Página | 39 General CCF12HR716MA CCF12HR716MA SilexConnect ® RF 7/16 Din Male Connector for 1/2” Coaxial Superflex Cable Type DINMA-1/2”H Nominal size 1/2" in Interface 7/16 DIN Male Body Style Right angle Mounting cable Model LCF12HR, HCAAY-50-09 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Tin Bronze/Silver Plating Insulator PTFE or TPX PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Brass/Trimetal Plating Gasket Silicon Rubber Silicon Rubber Durability >500 cycle >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 40. Página | 40 General CCF12HRNM CCF12HRNM SilexConnect ® RF N Male Connector for 1/2” Coaxial Superflex Cable Type DINNM-1/2”H Nominal size 1/2" in Interface N Male Body Style Straight Mounting cable Model LCF12HR, HCAAY-50-09 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 41. Página | 41 General CCF12HRNF CCF12HRNF SilexConnect ® RF N Female Connector for 1/2” Coaxial Superflex Cable Type DINNF-1/2” H Nominal size 1/2" in Interface N Female Body Style Straight Mounting cable Model LCF12HR, HCAAY-50-09 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 42. Página | 42 General CCF12HRNMA CCF12HRNMA SilexConnect ® RF N Male Connector for 1/2” Coaxial Superflex Cable Type DINNMA-1/2”H Nominal size 1/2" in Interface N Male Body Style Right angle Mounting cable Model LCF12HR, HCAAY-50-09 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 43. Página | 43 General CCF78STD716M CCF78STD716M SilexConnect ® RF 7/16 Din Male Connector for 7/8” Coaxial Cable Type DINM-7/8”L Nominal size 7/8" in Interface 7/16 DIN Male Body Style Straight Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze/Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal Plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 44. Página | 44 General CCF78STD716F CCF78STD716F SilexConnect ® RF 7/16 Din Female Connector for 7/8” Coaxial Cable Type DINF-7/8"L Nominal size 7/8" in Interface 7/16 DIN Female Body Style Straight Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze/Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal Plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 45. Página | 45 General CCF78STD716MA CCF78STD716MA SilexConnect ® RF7/16 Din Male Connector for 7/8” Coaxial Cable Type DINMA-7/8”L Nominal size 7/8" in Interface 7/16 DIN Male Body Style Right angle Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze/Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal Plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 46. Página | 46 General CCF78STDNM CCF78STDNM SilexConnect ® RF N Male Connector for 7/8” Coaxial Cable Type DINNM-7/8”L Nominal size 7/8" in Interface N Male Body Style Straight Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 47. Página | 47 General CCF78STDNF CCF78STDNF SilexConnect ® RF N Female Connector for 7/8” Coaxial Cable Type DINNF-7/8”L Nominal size 7/8" in Interface N Female Body Style Straight Mounting cable Models: copper LCF78STD, aluminum LCF78STL, HCTAY-50-22 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 48. Página | 48 General CCF158STD716M CCF158STD716M SilexConnect ® RF 7/16 Din Male Connector for 1-5/8” Coaxial Cable Type DINM-1-5/8”L Nominal size 1-5/8" in Interface 7/16 DIN Male Body Style Straight Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze/Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal Plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 49. Página | 49 General CCF158STD716F CCF158STD716F SilexConnect ® RF 7/16 Din Female Connector for 1-5/8” Coaxial Cable Type DINF-1-5/8"L Nominal size 1-5/8" in Interface 7/16 DIN Female Body Style Straight Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42 Technical Specifications Characteristics DIN Type Impedance 50 Ω Operating Voltage 2700 V Frequency Range ≤7.5 GHz Shielding Effectiveness >115 dB Inner Contact Resistance ≤0.4 MΩ Outer Contact Resistance ≤0.2 MΩ Intermodulation ≤-155 dBc Insulation Resistance >10000 MΩ Dielectric Withstanding Voltage 3000 V Insertion Loss =0.08 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze/Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal Plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 50. Página | 50 General CCF158STDNM CCF158STDNM SilexConnect ® RF N Male Connector for 1-5/8” Coaxial Cable Type DINNM-1-5/8”L Nominal size 1-5/8" in Interface N Male Body Style Straight Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 51. Página | 51 General CCF58STDNF CCF158STDNF SilexConnect ® RF N Female Connector for 1-5/8” Coaxial Cable Type DINNF-1-5/8”L Nominal size 1-5/8" in Interface N Female Body Style Straight Mounting cable Models: copper LCF158STD, aluminum LCF158STL, HCTAY-50-42 Technical Specifications Characteristics N Type Impedance 50 Ω Operating Voltage 1500 V Frequency Range ≤18.0 GHz Shielding Effectiveness >115 Db Inner Contact Resistance ≤0.8 MΩ Outer Contact Resistance ≤0.25 MΩ Intermodulation ≤-155 dBc Insulation Resistance >5000 MΩ Dielectric Withstanding Voltage 2500 V Insertion Loss =0.1 dB VSWR 0.8 ~ 1.0GHz ≤1.08 1.7 ~ 2.5GHz ≤1.10 Inner Conductor Pin Brass/Silver Plating Inner Conductor Socket Tin Bronze /Silver Plating Insulator PTFE or TPX Body & Outer Conductor Brass/Trimetal plating Gasket Silicon Rubber Durability >500 cycle Environmental Specifications Temperature Range -65 ºC ~ +165ºC Immersion Depth - Immersion Test Method IEC 60529:2001, IP65 Moisture Resistance Test Method IEC 60068-2-3 Mechanical Shock Test Method IEC 60068-2-27 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F Average Power, Ambient Temperature 40 °C | 104 °F
  • 52. Página | 52 General GLQ14DINKK627T Arrestors DINM–DINF 2700 Connector 7/16 Arrestors DINF–DINF 2700 Connector 7/16 Type DIN716 Surge arrestors are designed to protect wireless base stations, switching centers and transmission lines from the damaging effects of extreme high voltage surges caused by lightning strikes. We our lightning protection devices are designed and tested to the most demanding specifications. Their rugged construction utilizes solid metal housing, and superior plating, which results in outstanding system protection and operating continuity • Superior IM performance for reliable long-term operation • Excellent electrical performance, low VSWR, low insertion loss • Waterproof to IP68 • Including grounding wire kit • Totally maintenance free Technical Specifications Surge Arrestor Type Quarter Wave Design 90° Stub Coaxial Cable Type Foam Dielectric Connector Interface 7-16 DIN Frequency Range - MHz 690 - 2700 Minimum Return Loss, VSWR (dB) 690-2700 MHz: 1.19 (21) Insertion Loss, dB (Max) 0.10 3rd Order IM Product @ 2x20 Watts, dBc < -160 Center Contact Connector A Brass, silver plated Outer Contact Connector A Brass, white bronze Center Contact Connector B Brass, silver plated Outer Contact Connector B Brass, white bronze Body Brass, white bronze Dielectric PTFE Gasket Silicone Sealing class IP68 Operation Temperature, °C(°F) -45 to 85 (-49 to 185) Mounting / Grounding Bulkhead; Thread for grounding M8 Drill Hole Size, mm (in) M8
  • 53. Página | 53 Tools Feeder Cutting 1/2" Standard Feeder Cutting Tool Product Model: T-1/2"-EM Body Material: Hard Aluminium Alloy Match Cable: 1/2" Standard Feeder Cable Cut Inner Conductor: 6.0~11.5mm Stripper jacket: 15.0 & 20.0±1.0mm (Dual-Use) Working Style: Electric Pistol Drill or Manual Operation 1/2" Superflex Feeder Cutting Tool Product Model: TOL-1/2"SF-EM Body Material: Hard Aluminium Alloy Match Cable: 1/2" Standard Feeder Cable Cut Inner Conductor: 6.0~11.5mm *** Keep Dielectric: 2mm (Insulator Dielectric) Stripper jacket: 20.0±1.0mm (Stripper jacket) Working Style: Electric Pistol Drill or Manual Operation 1/2" Standard Feeder Cutting Tool Item Name: 1/2" Standard Feeder Cutting Tool Product Model: T-1/2-RS 1/2" Superflex Feeder Cutting Tool Item Name: 1/2" Superflex Feeder Cutting Tool Product Model: T-1/2SF-RS 7/8" Feeder Cutting Tool Product Model: TOL-7/8-HXC Body Material: PP Injection Molding Match Cable: 7/8" Feeder Cable Working Style: Manual Operation
  • 55. Página | 55 Global Worldwide Distribution Regulatory Compliance/Certifications RoHS 2011/65/EU RoHS Compliant Designed, manufactured and/or distributed under quality management system Silex System Telecom San Erasmo, 31 Nave 8 28021 - Madrid (Spain) Tel.: + 34 915 05 67 76 Mobile: +34 619 332 634 E-Mail: info@silexst.com Web: www.silexst.com Certified Products: ISO / EN / IEC Ordering No. Info32543SLink/WERE/09-2014 pA 1SFSD34 © 09.2014 Silexst Production & Powered By Silexst All specifications are subject to change. See www.silexst.com for the most current information. Revised: September 06, 2014 Silex Global Spain, S.L. | The information contained in this document is accurate to the best of our knowledge and representative of the part described herein. It may be necessary to make modifications to the part and/or the documentation of the part, in order to implement improvements. Silexst reserves the right to make such changes as required. Unless otherwise stated, all specifications are nominal. techsupport@silexst.com – www.silexst.com ©2014 Silexst All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of Silexst