SKYLINE
facades
Tel. +30 210 4009335
www.skylinefacades.com
info@skylinefacades.com
160-162, Laodikeias Street,
18451, Nikaia,
Greece
FACADE ENGINEERING SERVICES
12017-present
Assignment of:
-Shop Drawings
-Fabrication Drawings
-Installation Drawings
Scope of work:
-Aluminum Curtain Walls
-Aluminum Doors & Windows
-Aluminum Window Walls
-Glass Cladding
-Aluminum Fins
-Aluminum Slab Covers
250
5th AVENUE
New York, USA
12.7 [1/2"]
Clear Opening=977.9 [3'-2 1/2"] Clear Opening=466.7 [1'-6 3/8"]
152.4[6"]171.5[63/4"]
323.8[1'-03/4"]
406.4[1'-4"]
688.7[2'-31/8"]
342.6 [1'-1 1/2"] R.O.=2827 [9'-3 1/2"]
142.4 [5 5/8"] 176.4 [7"]
1574 [5'-2"]
SLAB COVER Edge Flush
to Brick Wall Edge
SLAB Edge
SLAB COVER Edge Flush
to Brick Wall Edge
SLAB Edge
DT-105
DT-106
sim
sim
DT-128
2876.6 [9'-5 1/4"] to Grid Line 3
E.O.S. 63.5 [2 1/2"]
E.O.S.215.9[81/2"]
140 [5 1/2"]
SLABEdge
82.6[31/4"]
toGridLineE
82.6[31/4"]
GL2
GL1 GL1
GL1A GL1A
GL1
GL1A
T.O.S. 14TH FL
126' - 10"
T.O.S. 15TH FL
136' - 1"
R.O.=2591[8'-6"]
F.D.=2555[8'-45/8"]
433.1[1'-5"]60[23/8"]315[1'-03/8"]60[23/8"]315[1'-03/8"]60[23/8"]403.1[1'-37/8"]60[23/8"]409[1'-41/8"]
BrickWallEdgeBeyond
GL2GL2
457.2[1'-6"]1676.4[5'-6"]457.2[1'-6"]
R.O.=2832 [9'-3 1/2"]
2876 [9'-5 1/4"] to Grid Line 3
T.O.S.1
126' -
FINEdge
[03] TpN- Plan 01
scale 1/8
[01] TpN- ELEVATION
scale 1/8
Max torque
(Nm) 35
Max torque
(Nm) 35
Maxtorque
(Nm)35
Maxtorque
(Nm)35
147.4 [5 3/4"]
18.3[3/4"]
10[3/8"]
7.3 [1/4"]
125.3 [4 7/8"]
46 [1 3/4"]4 [1/8"]
150[57/8"]
46 [1 7/8"] 4 [1/8"]
150[57/8"]
60[23/8"]
339.5[1'-13/8"]
Transom
Window Sash
Window Wall Receptor
Window Frame
Glazing Bead
Window Frame
Glazing
Mineral Wool Insulation 40mm
Aluminum Tray 1.5mm
Aluminum Sheet 2mm
Aluminum Angle 20x20x2 mm
Aluminum Angle 20x20x2 mm
27.1 [1 1/8"] 133 [5 1/4"] 17.3 [5/8"]
T.O.S. 8TH FL
71'- 4"
E
81.8 [3 1/4"] to Grid Line E
Interior Floor Finishes by others
228.6[9"]
Interior Floor Finishes by others
102[4"]
102 [4"]
Steel Studs by others
228.6[9"]
190.5[71/2"]
63.4 [2 1/2"]
Aluminum Fin
190.6 [7 1/2"]
12.7[1/2"]55[21/8"]379.7[1'-3"]19.6[3/4"]32.2[11/4"]75[3"]
58.9 [2 3/8"] 36.5 [1 3/8"] 57 [2 1/4"]
152.4 [6"]
47 [1 7/8"] 30 [1 1/8"] 135 [5 3/8"]
212 [8 3/8"]
75[3"]12.7[1/2"]
Window Investment by others
Line of Slab Covers
Line of Vertical Fins
81.8 [3 1/4"] 152.4 [6"] 158 [6 1/4"]
14.4 [5/8"]
Aluminum Angle 50X50
Aluminum Angle 50X50
Mineral Wool Insulation
Concrete Anchors M10X95 Spacing TBD
Waterproofing Membrane
Concrete Anchors M10X95 Spacing TBD
281.4 [11 1/8"]
87.9[31/2"]
25[1"]
40 [1 5/8"]
Drainage hole:
6x25mm @ 2' o.c.
2%
Project IDDATE 59380
DRAWING NUMBER
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
VERSION DATE DESCRIPTION
CHECKED by ETEM
00
250 5th Ave Hotel - New York
PROJECT TITLE
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
KEY PLAN
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
DT - 109
Type K - Section Detail
21 Apr 2018 Issued For Approval
REFERENCE DRAWINGS
TpK - GA01
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
Etem Window Wall System E86
01
21 Sept 2018
01 Issued For Approval21 Sept 2018
Maxtorque
(Nm)35
Maxtorque
(Nm)35
Max torque
(Nm) 35
152.4 [6"]
50 [2"]
43[13/4"]
5[1/4"]
40[15/8"]
60[23/8"]
75[3"]32[11/4"]40[15/8"]333.9[1'-11/8"]70[23/4"]23[7/8"]
18.2[3/4"]
27.1 [1 1/8"] 133 [5 1/4"] 17.3 [5/8"]
63.5 [2 1/2"]
Transom
Window Sash
Glazing Bead
Window Frame
Window Wall Receptor
Glazing Bead
Aluminum Sill
42[15/8"]
172.4 [6 3/4"] 281.4 [11 1/8"]
T.O.S. 7TH FL
62' - 1"
E
Glazing Bead
81.8 [3 1/4"] to Grid Line E
Aluminum Sheet 2mm
Aluminum Angle 20x20x2 mm
Interior Floor Finishes by others
Aluminum Fin
Window Wall Frame
30 [1 1/8"] 135 [5 3/8"]
25[1"]
Drainage through
baffle
53.9 [2 1/8"] 36.5 [1 3/8"] 62 [2 1/2"]
152.4 [6"]
147[53/4"]
58.9 [2 3/8"] 36.6 [1 1/2"] 56.9 [2 1/4"]
215 [8 1/2"] 26.4 [1"]
Line of Slab Covers
Line of Vertical Fins
Aluminum Angle 50X50
Aluminum Angle 50X50
Mineral Wool Insulation
Concrete Anchors M10X95 Spacing TBD
Waterproofing Membrane
34.7[13/8"]
Drainage hole:
6x25mm @ 2' o.c.
Project IDDATE 59380
DRAWING NUMBER
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
VERSION DATE DESCRIPTION
CHECKED by ETEM
00
250 5th Ave Hotel - New York
PROJECT TITLE
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
KEY PLAN
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
DT - 110
Type K - Section Detail
29 Apr 2018 Issued For Approval
REFERENCE DRAWINGS
TpK - GA01
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
Etem Window Wall System E86
01
21 Sept 2018
01 Issued For Approval21 Sept 2018
1396.6[4'-631/32"]836.4[2'-815/16"]3326[10'-1015/16"]
2718.2 [8'-11 1/32"]2693.2 [8'-10 1/32"]
494[1'-77/16"]
2359[7'-87/8"]
791.5 [2'-7 5/32"]
206 [8 1/8"]
252.1
[9 15/16"]
170 [6 11/16"]
206[81/8"]210
[89/32"]
3326[10'-1015/16"]
785[2'-629/32"]785[2'-629/32"]785[2'-629/32"]
00 Issued For Approval
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
REFERENCE DRAWINGS
KEY PLAN
SPECIFICATIONS
NOTES
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
28 Street
5thAvenue
A-102.02/A-200.01/A-301.01/A-303.01
A-506.01/A-630.01/A-635.00
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
08 Aug 2018
F
11[1/2"]
19[3/4"]6[1/4"]5[1/8"]
2[1/8"]
11[1/2"]
19[3/4"]6[1/4"]5[1/8"]
2[1/8"]
91[35/8"]
82[31/4"]toGridLineF
50 [2"]
91[35/8"]
50 [2"]
6 [1/4"]
8 [3/8"]
72 [2 7/8"]5 [1/4"]50 [2"]21 [7/8"]
75[3"]
52 [2"]93 [3 5/8"]
Door FrameDoor SashGlazing Bead
Glazing Glazing
301[11 7
8''] to Grid Line 3
Pressure Plate and Mullion Cap
110[43/8"]
Mullion
15[5/8"]
Transom Projection
1830 [6'] Clear Opening
Project IDDATE 59380
DT - 308
DRAWING NUMBER
ST03-Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 Issued For Approval
250 5th Ave Hotel - New York
PROJECT TITLE
ARCHITECT
PROVIDER
SERVICES
REFERENCE DRAWINGS
KEY PLAN
SUBCONTRACTOR
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/1'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
GA - 304
08 Aug 2018
08 Aug 2018
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
3
F
11[1/2"]
19[3/4"]6[1/4"]5[1/8"]
2[1/8"]
50 [2"]
15[5/8"]
50 [2"] 25 [1"]
110[43/8"]
114[41/2"]
82[31/4"]toGridLineF
Mullion
Gasket
Transom Projection
1 [0"]
Mineral Wool Insulation
21 [7/8"]
Rubber Joint
Pressure Plate and Mullion Cap
Glazing
60[23/8"]40[15/8"]
20x40x2mm
Aluminum L
Shaped
40x20x2 mm Aluminum Tube
60x20x2 mm Aluminum Tube
Interior Finishes
by Others
Steel Studs by Others
2693.2 [8'-10''] Frame Opening
26 [1"] to Grid Line 3
PVC Spacen
12 [1/2"]
130 [5 1/8"]
50[2"]
50[2"]
90 [3 1/2"]
95 [3 3/4"]
5 [1/4"] 2 [1/8"]
12 [1/2"]
Mullion
Baker Rod & Sealant
GlazingTransom Projection
441.4[1'-53
8'']toGridLineF
Pressure Plate and Mullion Cap
3381.2 [11' - 1 1
8''] to Grid Line 3
Aluminum Spigot
(part of bottom curtain wall bracket)
10mm Aluminum Plate
Bracket Below
10[3/8"]
Baker Rod & SealantPVC Spacen
3367.1[11'-09
16'']RoughOpening
PVC Spacen
Project IDDATE 59380
DT - 310
DRAWING NUMBER
ST03-Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 Issued For Approval
250 5th Ave Hotel - New York
PROJECT TITLE
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
KEY PLAN
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/1'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
GA-304
REFERENCE DRAWINGS
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
08 Aug 2018
08 Aug 2018
22018 – present
Assignment of:
-Shop Drawings
-Fabrication Drawings
-Installation Drawings
Scope of work:
-Aluminum Curtain Walls
-Aluminum Doors & Windows
-Aluminum Slab Covers
-Aluminum Fins
68 - 70
SPRING
STREET
New York, USA
2392.9[7'-101/4"]2382.1[7'-93/4"]1255.7[4'-13/8"]
FO6030.6[19'-93/8"]
55.8[21/4"]
(Sill)
574.7 [1'-10 5/8"]574.7 [1'-10 5/8"]
558.8[1'-10"]
D E
1291.4 [4'-2 7/8"]
5832.5 [19'-1 5/8"]
609.6[2']
T.O.F. 3rd FL
28' - 00"
6096[20'](8''tilesx30)609.6[2']609.6[2']
D.1
609.6[2']
609.6[2']
30' - 00"
50' - 00"
RO6151.6[20'-21/8"]
ROfromSteelStudtoSteelStud
UnitsA,B
L.O. SteelStud
50' - 02"
FO 2328.1 [7'-7 5/8"]
TO 2346.3 [7'-8 3/8"]
R.O.=2352.6 [7'-8 5/8"]
FO 1158.9 [3'-9 5/8"]
TO 1177.9 [3'-10 3/8"]
RO 1184.2 [3'-10 5/8"]
From Steel Stud to Steel Stud
FO 1158.9 [3'-9 5/8"]
TO 1177.9 [3'-10 3/8"]
RO 1184.2 [3'-10 5/8"]
From Steel Stud to Steel Stud
2432.1[7'-113/4"]1155.7[3'-91/2"]2498.7[8'-23/8"]614.4[2'-01/8"]
50[2"]1775.6[5'-97/8"]50[2"]506.5[1'-8"]50[2"]1155.7[3'-91/2"]50[2"]1786.3[5'-103/8"]50[2"]506.5[1'-8"]
50[2"]
55.8[21/4"]
208[81/4"]
T.O.F. 3rd FL
28' - 00"
T.O.F. 4th FL
40' - 00"
T.O.F. 5th FL
52' - 00"
406.4[1'-4"]
26.8 [1"]
406.4[1'-4"]614.4[2'-01/8"]
55.8[21/4"]
406.4[1'-4"]
165.1 [6 1/2"]
125.2 [4 7/8"]
UNITS A - B ELEVATION UNITS A - B SECTION
FO 3481.6 [11'-5 1/8"]
RO 3505.2 [11'-6"]
T.O.F. 2nd FL
16' - 00"
T.O.F. 1st FL
0' - 00"
979.1 [3'-2 1/2"]
200 [7 7/8"]
873.4 [2'-10 3/8"]
200 [7 7/8"]
979.1 [3'-2 1/2"]
2360[7'-87/8"]1294.4[4'-3"]2997.8[9'-10"]
DCB
127.8 [5"]127.8 [5"]
1244.5[4'-1"]
D.1A.9
FO7896.7[25'-107/8"]
RO7916.9[25'-113/4"]
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
T.O.F. 2nd FL
16' - 00"
T.O.F. 1st FL
0' - 00"
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
T.O.F. 2nd fl
15' - 10"
T.O.S. 1st FL
-0' - 02"
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
2028.4 [6'-7 7/8"]
Project IDDATE 23 May 2018 68SPR
106
DRAWING NUMBER
North Partial Elevation and Section
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/16'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Section 106 -2 Scale as notedElevation 106 -1 Scale as noted Section 106 -3 Scale as noted
200 [7 7/8"]
979.1 [3'-2 1/2"]
2360[7'-87/8"]1294.4[4'-3"]2997.8[9'-10"]
D
127.8 [5"]
1244.5[4'-1"]
D.1
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
T.O.F. 2nd FL
16' - 00"
T.O.F. 1st FL
0' - 00"
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
T.O.F. 2nd fl
15' - 10"
T.O.S. 1st FL
-0' - 02"
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
2028.4 [6'-7 7/8"]
Project IDDATE 23 May 2018 68SPR
106
DRAWING NUMBER
North Partial Elevation and Section
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/16'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Section 106 -2 Scale as notedElevation 106 -1 Scale as noted Section 106 -3 Scale as noted
Maxtorque
(Nm)50
Max torque
(Nm) 50
50 [2"]
Aluminum Mullion
Aluminum Angle
40 x 40 x 2
20 [3/4"]
88[31/2"]
50 [2"]
11.8 [1/2"]
Pressure Plate
Aluminum Cap
120 x 20 x 2
55 [2 1/8"] 14.2 [1/2"]
68.3 [2 3/4"]
20 [3/4"]
93.7[33/4"]
28[11/8"]
128.9[51/8"]
Projected
Window
Sash
Terra cotta
by Others
Interior Finishes
By Others
Seal on Backer Rod
Waterproofing
Membrane
SF1 F.D. 13'-4 1/8''
11.8 [1/2"]
SF2 F.D. 11'-5 1/8''
SF1 R.O. 13'-5''
SF2 R.O. 11'-6''
Max torque
(Nm) 50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
200 [7 7/8"]
20 [3/4"]50 [2"]20 [3/4"]
55 [2 1/8"]55 [2 1/8"]
88[31/2"]
30[11/8"]88[31/2"]
40.3 [1 5/8"]
68.3 [2 3/4"]
200 [7 7/8"]
77[3"]
87[33/8"]63[21/2"]28[11/8"]
130[51/8"]25.4[1"]
Aluminum Mullion
Pressure Plate
Aluminum Cap
120 x 20 x 2
Projected
Window
Sash
100 x 20 x 2
Project IDDATE 23 May 2018 68SPR
110
DRAWING NUMBER
North Plan Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Detail 110 - 2
Scale as noted
Detail 110 - 2
Scale as noted2nd Floor SF1 Ref. Shildan 5.3, 5.2, 5.1
E85104
2
1
50 [2"]
20 [3/4"]8 [3/8"]40.4 [1 5/8"]20 [3/4"] 8 [3/8"] 40.4 [1 5/8"]
56[21/4"]37.8[11/2"]
56[21/4"]37.8[11/2"]77[3"]166.7[61/2"]
25.9[1"]toGridLine1
14.2 [1/2"] 50 [2"] 14.2 [1/2"]
1460.5 [4'-9 1/2"] to Grid Line D1
Aluminum Mullion
Aluminum Cap
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Line of Mullions and Transcents Edge
1
77[3"]56[21/4"]37.8[11/2"]166.7[61/2"]
28[11/8"]
50 [2"]12.7 [1/2"] 68.4 [2 3/4"]
25.9[1"]toGridLine1
1456 [4'-9 3/8"] to Grid Line D1
R.O.=1184 [3'-10 5/8"] (Type A,A1,C)
F.D.=1159 [3'-9 5/8"]
337.4[1'-11/4"]
Aluminum Mullion
Aluminum Mullion
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Terracota Cladding by others
Interior Walls by others
Line of Mullions and Transcents Edge
Pressure Plate
Cap
9.6 [3/8"]
3' - 9 15/16"
Seal on Backer Rod
Detail 103 -1
scale as noted
Detail 103 -2
scale as noted
Project IDDATE 23 May 2018 68SPR
103
DRAWING NUMBER
North Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Ref. Shildan 5.4, 5.5, 5.6
E85104
2
1
50 [2"]
20 [3/4"]8 [3/8"]40.4 [1 5/8"]20 [3/4"] 8 [3/8"] 40.4 [1 5/8"]
56[21/4"]37.8[11/2"]
56[21/4"]37.8[11/2"]77[3"]166.7[61/2"]
25.9[1"]toGridLine1
14.2 [1/2"] 50 [2"] 14.2 [1/2"]
1460.5 [4'-9 1/2"] to Grid Line D1
Aluminum Mullion
Aluminum Cap
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Line of Mullions and Transcents Edge
1
77[3"]56[21/4"]37.8[11/2"]166.7[61/2"]
28[11/8"]
50 [2"]12.7 [1/2"] 68.4 [2 3/4"]
25.9[1"]toGridLine1
1456 [4'-9 3/8"] to Grid Line D1
R.O.=1184 [3'-10 5/8"] (Type A,A1,C)
F.D.=1159 [3'-9 5/8"]
337.4[1'-11/4"]
Aluminum Mullion
Aluminum Mullion
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Terracota Cladding by others
Interior Walls by others
Line of Mullions and Transcents Edge
Pressure Plate
Cap
9.6 [3/8"]
3' - 9 15/16"
Seal on Backer Rod
Detail 103 -1
scale as noted
Detail 103 -2
scale as noted
Project IDDATE 23 May 2018 68SPR
103
DRAWING NUMBER
North Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Ref. Shildan 5.4, 5.5, 5.6
Aluminum Mullion
Window Sash
Window Frame
Aluminum Cap
Glass
Slab Edge of 4th & 6th fl.
Slab Edge of 3th & 5th fl.
50 [2"]
20.4 [3/4"] 53 [2 1/8"]20.4 [3/4"]73.4 [2 7/8"]
95.5[33/4"]166[61/2"]75.5[3"]
31.5[11/4"]
67.5[25/8"]
188.8 [7 3/8"]
50 [2"]69.4 [2 3/4"] 69.4 [2 3/4"]
95.5[33/4"]166[61/2"]
35.5[13/8"]8[3/8"]
50 [2"]
20.4 [3/4"] 53 [2 1/8"]
50 [2"] 69.4 [2 3/4"]
25.9[1"]toGridLine1
1
75.5[3"]
32[11/4"]
R.O.=1184 [3'-10 5/8"] (Type A,A1,C)
F.D.=1159 [3'-9 5/8"]
1456 [4'-9 3/8"] to Grid Line D1
Aluminum Mullion
Window Sash
Window Frame
Aluminum Mullion
Glass
Slab Edge of 4th & 6th fl.
Slab Edge of 3th & 5th fl.
12.7 [1/2"]
Pressure Plate
Cap
Concealed sash
window frame
Interior Finishes
By Others
Terra cotta
by Others
9.6 [3/8"]
3' - 9 15/16"
Seal on Backer Rod
Detail 102 - 1
scale as noted
32[11/4"]
Detail 102 - 2
scale as noted
Project IDDATE 23 May 2018 68SPR
102
DRAWING NUMBER
North Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Ref. Shildan 5.4, 5.5, 5.6
556.5[1'-97/8"]
50[2"]
14.3[1/2"]
68.4[23/4"]
Custom
Wind Load bearing Bracket
55.8[21/4"]
60.3[23/8"]
101.6 [4"]
346.1[1'-15/8"]
165.1 [6 1/2"]
123.2 [4 7/8"]
63.4 [2 1/2"]
Mineral
Wool
50 x 50 x 3
Aluminum cap
Aluminum transom
1
63.4 [2 1/2"]
M10 Bolt Set
406.4[1'-4"]
T.O. SteelStud
30' - 00"
110.6[43/8"]
Waterproof Membrane
660.4[2'-02'']
toSlab
TERRACOTAFACEPROJECTION
Maxtorque
(Nm)50
Maxtorque
(Nm)50
T.O.F. 4th FL
40' - 00"
M12 x 140
concrete anchor
120[43/4"]
Custom
Dead Load
bearing Bracket
53[21/8"]
73.4[27/8"]
75.5 [3"]
69.4[23/4"]50[2"]
140 [5 1/2"]26 [1"]
1
4th Fl.
T.O.S. 4th FL
39' - 10"
368.3 [1'-2 1/2"]
312 [1'-0 1/4"]
38' - 08"
138.2[51/2"]
TERRACOTAFACEPROJECTION
556.5[1'-97/8"]
73.4[27/8"]
68.4[23/4"]
50[2"]69.4[23/4"]14.3[1/2"]
9[3/8"]
127 [5"]26 [1"]
Projected window
sash
Concealed sash
window
1
RO6146.8[20'-02'']
ROfromSteelStudtoSteelStud
UnitsA,B
Detail 105 -1
Scale as noted
Detail 105 -2
Scale as noted
Detail 105 -2
Scale as noted
Project IDDATE 23 May 2018 68SP
105
DRAWING NUMBER
North Section Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSIO
00
VERSION DATE DESCRIPTION
CHECKED by ETE
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 2'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Sill Detail A-B Ref. Shildan 5.15
556.5[1'-97/8"]
50[2"]
14.3[1/2"]
68.4[23/4"]
Custom
Wind Load bearing Bracket
55.8[21/4"]
60.3[23/8"]
101.6 [4"]
346.1[1'-15/8"]
165.1 [6 1/2"]
123.2 [4 7/8"]
63.4 [2 1/2"]
Mineral
Wool
50 x 50 x 3
Aluminum cap
Aluminum transom
1
63.4 [2 1/2"]
M10 Bolt Set
406.4[1'-4"]
T.O. SteelStud
30' - 00"
110.6[43/8"]
Waterproof Membrane
660.4[2'-02'']
toSlab
TERRACOTAFACEPROJECTION
Maxtorque
(Nm)50
Maxtorque
(Nm)50
T.O.F. 4th FL
40' - 00"
M12 x 140
concrete anchor
120[43/4"]
Custom
Dead Load
bearing Bracket
53[21/8"]
73.4[27/8"]
75.5 [3"]
69.4[23/4"]50[2"]
140 [5 1/2"]26 [1"]
1
4th Fl.
T.O.S. 4th FL
39' - 10"
368.3 [1'-2 1/2"]
312 [1'-0 1/4"]
38' - 08"
138.2[51/2"]
TERRACOTAFACEPROJECTION
556.5[1'-97/8"]
73.4[27/8"]
68.4[23/4"]
50[2"]69.4[23/4"]14.3[1/2"]
9[3/8"]
127 [5"]26 [1"]
Projected window
sash
Concealed sash
window
1
RO6146.8[20'-02'']
ROfromSteelStudtoSteelStud
UnitsA,B
Detail 105 -1
Scale as noted
Detail 105 -2
Scale as noted
Detail 105 -2
Scale as noted
Project IDDATE 23 May 2018 68SP
105
DRAWING NUMBER
North Section Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSI
00
VERSION DATE DESCRIPTION
CHECKED by ETE
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 2'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Sill Detail A-B Ref. Shildan 5.15
50[2"]
26 [1"]
166 [6 1/2"]
241.5 [9 1/2"]
32 [1 1/4"]
96.5 [3 3/4"]
9.6[3/8"]
69.4[23/4"]
73.4[27/8"]
1
Custom
Wind Load bearing Bracket
M10 Bolt Set
transom
Window frame
Concealed sash
window
Aluminum cap
Pressure plate
5th Fl.
L.O. SteelStud
50' - 02"
50' - 08"
Structural Framing by GC
for windows attachments and TC
(TYP)
Structural Framing by GC
for windows attachments and TC
(TYP)
50' - 00"
55.6[21/4"]
RO6146.8[20'-02'']
ROfromSteelStudtoSteelStud
UnitsA,B
312 [1'-0 1/4"]
203.2 [8"]
TERRACOTAFACEPROJECTION
Detail 104 -1
Scale as noted
Head Detail A-B Ref. Shildan 5.14
Maxtorque
(Nm)50
Max torque
(Nm) 50
50 [2"]
Aluminum Mullion
Aluminum Angle
40 x 40 x 2
20 [3/4"]
88[31/2"]
50 [2"]
11.8 [1/2"]
Pressure Plate
Aluminum Cap
120 x 20 x 2
55 [2 1/8"] 14.2 [1/2"]
68.3 [2 3/4"]
20 [3/4"]
93.7[33/4"]
28[11/8"]
128.9[51/8"]
Projected
Window
Sash
Terra cotta
by Others
Interior Finishes
By Others
Seal on Backer Rod
Waterproofing
Membrane
SF1 F.D. 13'-4 1/8''
11.8 [1/2"]
SF2 F.D. 11'-5 1/8''
SF1 R.O. 13'-5''
SF2 R.O. 11'-6''
Max torque
(Nm) 50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
200 [7 7/8"]
20 [3/4"]50 [2"]20 [3/4"]
55 [2 1/8"]55 [2 1/8"]
88[31/2"]
30[11/8"]88[31/2"]
40.3 [1 5/8"]
68.3 [2 3/4"]
200 [7 7/8"]
77[3"]
87[33/8"]63[21/2"]28[11/8"]
130[51/8"]25.4[1"]
Aluminum Mullion
Pressure Plate
Aluminum Cap
120 x 20 x 2
Projected
Window
Sash
100 x 20 x 2
Project IDDATE 23 May 2018 68SPR
110
DRAWING NUMBER
North Plan Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Detail 110 - 2
Scale as noted
Detail 110 - 2
Scale as noted2nd Floor SF1 Ref. Shildan 5.3, 5.2, 5.1
32012-2013
Assignment of:
-New Aluminum Cladding System
development (W-1016)
-Tender Stage Estimation
-Shop Drawings
-Bill of Materials
-Fabrication Drawings
-Installation Drawings
Scope of work:
-Aluminum Composite Panels Cladding
-Decorative Aluminum Screen Walls
-Suspended Metal Ceilings
TORONTO
PREMIUM
OUTLET
Toronto, Canada
M10 connection Parts ---->
5mm thick ------->
PR
M10 connection parts
M10 safety nuts
L angle L-10(47-90mm)
Lower part
of gallery joist
(by others)
M10 Channel nuts
CSN4141
washer
M10 Channel nuts
CN4141
L-18B
(5mm thick)
Upper part
of gallery joist
(by others)
L-02
(5mm thick)
L-01
(5mm thick)
M10 connection parts
long
Lower part
of gallery joist
(by others)
Upper part
of gallery joist
(by others)
PR
Pair rods for
indirect suspension
of basic part
P4141
detail 6
804.67 64
detail 6b
PR (P4141E)
Pair rods
Under Gallery parts
Length
(mm)Code Qnty
(pcs)
-L-10 64
M10 connection Parts ---->
5mm thick ------->
PR
M10 connection parts
M10 safety nuts
L angle L-10(47-90mm)
Lower part
of gallery joist
(by others)
M10 Channel nuts
CSN4141
washer
M10 Channel nuts
CN4141
L-18B
(5mm thick)
Upper part
of gallery joist
(by others)
L-02
(5mm thick)
L-01
(5mm thick)
M10 connection parts
long
Lower part
of gallery joist
(by others)
Upper part
of gallery joist
(by others)
PR
Pair rods for
indirect suspension
of basic part
P4141
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
detail 6
804.67 64
Scale:
Project No: 1203 Td
1 : 8
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No: Susp_partUGal
Pair rods under gallery joist
detail 6b
All dimensions added by Elegant Facade
are in mm.
PR (P4141E)
Pair rods
Under Gallery parts
Length
(mm)Code Qnty
(pcs)
-L-10 64
-M10 channel nuts CSN4141
M10 channel nuts CN4141
-
64
M10 connection part 64
M10 safety nuts
256
512
Washer 448
L-18 64
Plate L-01 64
Plate L-02 64
M10 connection part(long) 128
-
-
-
-
-
-
-
Detail 5b
Detail 5a
Detail 5a
M10 Channel nuts
CSN4141
Angle L-09B
M10 connection
parts
substructure rod
P4141x2(41x82mm)
suspension rod
P4141(41x41mm)
substructure rod
P4141x2(41x82mm)
suspension rod
P4141(41x41mm)
M10 Channel nuts
CSN4141
M10
safety nuts
Washer
M10 Channel nuts
CN4141
M10 connection
parts
Angle L-09B
Angle L-18B
Details 5a - 5b Exploded Detail 5a
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES: Project No:1203 Td
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No:SubSusp_Det-5
Substructure between
Scale: 1 : 25
parts -suspension detail
suspension rod
P4141(41x41mm)
substructure rod
P4141x2(41x82mm)
Angle L-09B
M10 connection part
M10 Channel nuts
CSN4141
M10 Channel nuts
CN4141
M10 safety nuts
washer
M10
Channel nuts
CN4141
Angle L-13E
Perforated panel
Exploded Detail 1
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
Scale:
Project No:1203 Td
1 : 25
Revision A:
Revision B:
Detail ID:
Part No:Sub_Det-1
RCP substructure detail (corner)All dimensions added by
Elegant Facade are in mm.
substructure rod
P4141x2(41x82mm)
suspension rod
P4141(41x41mm)
Angle L-13E
M10 Channel nuts
CSN4141
Angle L-09B
Exploded Detail 1b
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
Scale:
Project No:1203 Td
1 : 25
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No:Sub_Det-1b
RCP substructure detail(corner)All dimensions added by Elegant
Facade are in mm.
M10 Channel nuts
CSN4141
M10 Channel nuts
CN4141
M10 Channel
nuts CSN4141
M10
safety nuts
suspension rod
P4141(41x41mm)
L-09B
substructure rod
P4141x2(41x82mm)
substructure rod
P4141x2(41x82mm)
Angle L-18B
Angle L-09B
Angle L-18B
Plate L-02A
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
Scale:
Project No: 1203 Td
1 : 18 , 1:14
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No: Sr_A-B-C-D
Suspension rods parts details
All dimensions added by Elegant Facade
are in mm.
2040 9Sr-A(P4141 41x41mm)
part A
Suspension rods &
componets
Length
(mm)Code Qnty
(pcs)
2588
1735 12Sr-B(P4141 41x41mm)
part B
Sr-D(P4141 41x41mm)
part D
92040
3588
Sr-C (P4141 41x41mm)
part C
1278 27
662.7 3
L-09B(partA) 66
M10 channel nuts CSN4141 130
M10 safety nuts
Washer 132
M10 connection parts
M10 channel nuts CN4141 66
68
- -
-
-
-
-
-
-
132
L-02A 2-
Weather Barrier
Tyvec HomeWrap
Seathing
PreDrilled E-16150
ST 4,2 (No 10)
Length 30mm
Fix PreDrilled E-16150 perimetrically at
the under edge of the canopy, usind No
10 Selfdrilling screws
PreDrilled E-16900
Fix PreDrilled E-16900 at the middle,
usind No 10 Selfdrilling screws
Canopy Edge
INDICATIVE APPLY
Elegant Façade Inc.
Architectural Solutions
Alumicore
WS 1016
1203 GD-10
Generic Drawings For
PROJECT 1203 (TPO)
Alumicore ACP
Slide the ACP panel into the grooves.
Canopy Edge
INDICATIVE APPLY
Elegant Façade Inc.
Architectural Solutions
Alumicore
WS 1016
1203 GD-16
Generic Drawings For
PROJECT 1203 (TPO)
BETWEEN TWO TYPICAL BRACKETS (EVERY 5ft) WE PLACE 5 PLATE
HOLDERS (EVERY 1ft) STARTING 1/2 ft FROM THE EDGE.
1ft
1ft
1ft
1ft
1
2
ft
1
2
ft
1ft
1
2
ft
5ft
1
2
ft
6
6.1 6.2
1213.4 [3'-11 3/4"] 1213.4 [3'-11 3/4"] 1214.2 [3'-11 3/4"] 1212.9 [3'-11 3/4"]
63.1 [2 1/2"]
to Grid Line 6.1
3048.8 [10']
914.6 [3']
101.6 [4"]
101.6 [4"]
914.6 [3']
2082.3[6'-10"]
1778[5'-10"]
2082.3[6'-10"]
1778[5'-10"]
456.8[1'-6"]
50[2"]
100' - 0'' T/O FIN. FLOOR
117' - 6'' T/O FRAMING
5333.7[17'-6"]
S.3
S.1
1213.4 [3'-11 3/4"] 1213.4 [3'-11 3/4"] 1214.2 [3'-11 3/4"] 1212.9 [3'-11 3/4"]
63.1 [2 1/2"]
to Grid Line 6.1
2205.2 [7'-2 7/8"] to Grid Line 6.2
743[2'-51/4"]
toGridLineS.1
304.8[1']
6 6.1 6.2
03
GA-02
sim PD-06
S.1
124' - 0'' T/O STEEL BEAM
203.2[8"]
S.3
117' - 6'' T/O FRAMING
110' - 9'' U/S STEEL
100' - 0'' T/O FIN. FLOOR
203.2[8"]583.9[1'-11"]
304.8 [1']
sim SD-19
508[1'-8"]506.9[1'-8"]509.9[1'-81/8"]508[1'-8"]279[11"]
2082.6[6'-10"]
743 [2'-5 1/4"]
to Grid Line S.1
3251.4[10'-8"]
02. Floorplan
1/30
03. Section
1/16
01. ELevation
1/30
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 11 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B12-GA02
Partial South Elevation - Section
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
as Noted @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
A12-01, A12-01A, A12-03, A12-04, A12-09
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
42018
Assignment of:
-New Aluminum Cladding System
development (W-1415)
-Tender Stage Estimation
-Shop Drawings
-Bill of Materials
-Fabrication Drawings
-Installation Drawings
Scope of Work:
-Aluminum Composite Panels Cladding
-Brick Cladding
-Fiber Cement Board Cladding
-Decorative Aluminum Screen Walls
TORONTO PREMIUM OUTLET_
EXPANSION
Toronto, Canada
U.1T.9T.5
124' - 4'' T/O PARAPET
122' - 4'' T/O PARAPET
137' - 0'' T/O PARAPET
T
1158.3 [3'-9 5/8"]1219.2 [4']1219.2 [4']1219.2 [4']605.5 [1'-11 7/8"]
709.8[2'-4"]
6637.9[21'-93/8"]
S.10
1219.2 [4'] 1219.2 [4'] 1219.2 [4'] 1219.2 [4']
303.4[1']
4876.8 [16']
02
GA-07
431.4[1'-5"]
864.4[2'-10"]
253.2[10"]
864.4[2'-10"]
2438.4[8']
764 [2'-6 1/8"] 384.3 [1'-3 1/8"]
1201.9 [3'-11 3/8"]
108.4[41/4"]
303.4[1']
80.3[31/8"]
520.2[1'-81/2"]
456.7[1'-6"]
4217 [13'-10"]
5283.2 [17'-4"]
92.6[35/8"]
103[4"]
10.6[3/8"]
1224.6 [4']1224.6 [4'] 690.6 [2'-3"]690.6 [2'-3"]
1224.6 [4']1224.6 [4'] 690.6 [2'-3"]690.6 [2'-3"]
1040.9[3'-5"]
100' - 0'' F.FL.
1322.2[4'-4"]
MP2 MP2MP2MP2
MP2MP2
MP1MP1
CL1
CL1CL1
MP2MP2
B1
B1
S1
S1
02
GA-07
01
GA-07
11.10
11.8
T.9T.5
S.10 T
U.1
307.8[1'-01/8"]
709.8 [2'-4"] 336.1 [1'-1 1/4"]
1219.2[4']413.5[1'-41/4"]
788.4 [2'-7"] 413.5 [1'-4 1/4"]
1201.9 [3'-11 3/8"]
357.6[1'-21/8"]
toGridLine11.10
535.1 [1'-9 1/8"]
to Grid Line U.1
666.8 [2'-2 1/4"]
to Grid Line U.1
509.4[1'-8"]
sim PD-02
761.3 [2'-6"]
to Grid Line S.10
609.6 [2']
to Grid Line T
422.3[1'-45/8"]
toGridLine11.8
1330.3 [4'-4 3/8"]
720.7 [2'-4 3/8"]
to Grid Line T
3159.1 [10'-4 3/8"] to Grid Line T 1338.4 [4'-4 3/4"]
4497.5 [14'-9 1/8"] to Grid Line T
934.7 [3'-0 3/4"]
933
[3
'-0
3/4
"]
138.6[51/2"]
toGridLine11.10
sim PD-07 sim PD-07
sim PD-07
175.6[67/8"]
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 11 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B12-GA06
Partial East Elevation
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/30 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
A12-01, A12-01B, A12-03, A12-05, A12-06, A12-10
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
02. Floor plan
1/30 20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches o
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
Q.12 Q.10
125' - 8'' T/O PARAPET
2438.4[8']
1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"]
1219.3 [4'] 1219.3 [4'] 1219.3 [4'] 1219.3 [4'] 1303.7 [4'-3 3/8"]1219.3 [4']1219.3 [4']1219.3 [4']1305.7 [4'-3 3/8"]
03
GA-06
03
GA-06
03
GA-07
819[2'-81/4"]964.2[3'-2"]963.5[3'-2"]963.5[3'-2"]963.5[3'-2"]951.9[3'-11/2"]
1219.3 [4']
9250.7 [30'-4 1/4"]
101.6[4"]
2183.7[7'-2"]
101.6[4"]
2183.7[7'-2"]
03
GA-07
MP2
MP2MP2 MP4
1219.3 [4']1219.3 [4']1219.3 [4']1219.3 [4']1219.3 [4']967.6 [3'-2 1/8"] 967.7 [3'-2 1/8"]
1727.2[5'-8"]914.7[3']
MP2
1727.2[5'-8"]914.7[3']
MP2
7250 [23'-9 3/8"]
4Q
5Q
1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"]
305.6[1']
50[2"]
03
GA-07
03
GA-07
03
GA-06
03
GA-06
251.4[97/8"]
204.7[8"]
776.1 [2'-6 1/2"]
251.6
[9
7/8"]
697.5
[2
'-3
1/2"]
204.7
[8
"]
204.7
[8
"]
254.4
[1
0"]
697.5
[2
'-3
1/2"]
776.1 [2'-6 1/2"]
251.4[97/8"]
204.7[8"]
125' - 8'' T/O PARAPET
4Q
125' - 6'' T/O STEEL
117' - 6'' U/S DECK
112' - 0'' U/S OF CANOPY
109' - 0'' T/O GLAZING
110' - 3/8'' U/S STEEL
100' - 0'' T/O FIN. FLOOR
5Q
571.7[1'-101/2"]571.7[1'-101/2"]574.7[1'-105/8"]568.7[1'-103/8"]
358.6 [1'-2 1/8"]
355.6 [1'-2"]
305.6 [1']
2438.4[8']4329.4[14'-21/2"]
6717[22'-01/2"]
MP2
DATE 08 Jun 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
08 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B10-GA7
North West Elevation & Plan-Section
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
as noted @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
10
00
03. Section 1/1602. Plan 1/30
A10-01, A10-01A, A10-03, A10-04, A10-08
18 Jun 2018 Issued For Approval01
125' - 8'' T/O PARAPET
4Q
125' - 6'' T/O STEEL
117' - 6'' U/S DECK
112' - 0'' U/S OF CANOPY
109' - 0'' T/O GLAZING
110' - 3/8'' U/S STEEL
100' - 0'' T/O FIN. FLOOR
5Q
571.7[1'-101/2"]571.7[1'-101/2"]574.7[1'-105/8"]568.7[1'-103/8"]
358.6 [1'-2 1/8"]
355.6 [1'-2"]
305.6 [1']
2438.4[8']4329.4[14'-21/2"]
6717[22'-01/2"]
MP2
DATE 08 Jun 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
08 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B10-GA7
North West Elevation & Plan-Section
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
as noted @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
10
00
03. Section 1/16
A10-01, A10-01A, A10-03, A10-04, A10-08
18 Jun 2018 Issued For Approval01
1219.2 [4']1219.6 [4'] 1219.2 [4'] 1102 [3'-7 3/8"]726.4 [2'-4 5/8"]
417.6 [1'-4 1/2"]
31.133.134
132' - 0'' T/O PARAPET
01
GA-10
4368.8[14'-4"]
5486.4 [18']
6014.7 [19'-8 3/4"]
1324[4'-41/8"]
101.6[4"]
282.4 [11 1/8"]3226.3 [10'-7"]
1330.2[4'-43/8"]
1219.2 [4']1219.6 [4'] 1219.2 [4'] 1102 [3'-7 3/8"]726.4 [2'-4 5/8"]
990.6 [3'-3"]
1219.2 [4'] 1219.2 [4'] 1219.2 [4']
1366.5 [4'-5 3/4"]
31
1320.8[4'-4"]
1207 [3'-11 1/2"]
1219.2 [4']1219.2 [4']721.8 [2'-4 3/8"]
1219.6 [4']1219.6 [4']1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4']871.3 [2'-10 1/4"] 871.3 [2'-10 1/4"]
5080 [16'-8"]
TT.9
TT.8
TT.7
3707.6 [12'-2"]
305.5[1']
50[2"]
1205.5 [3'-11 1/2"]
262.8[103/8"]
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
00
VERSION DATE DESCRIPTION
Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B14-GA08
Partial North Elevation & Plan
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/30 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
10
00
05 Jul 2018
05 Jul 2018
A14-01A, A14-03, A14-04, A14-09, A14-10
14
01. ELevation
1/30
02. Floorplan
1/30
M10threadedRod
110 [4 3/8"]
150[57/8"]
80[31/8"]
50 [2"] 255.6 [10 1/8"] 50 [2"] 50.8 [2"]
9.8 [3/8"]
18.6 [3/4"] 152.4 [6"] 15.9 [5/8"]
3 [1/8"]
50.8 [2"]
50[2"]424.7[1'-43/4"]50[2"]
101.6[4"]50.8[2"]101.6[4"]50.8[2"]101.6[4"]50.8[2"]101.6[4"]25[1"]25[1"]
50 [2"]
50[2"]
3[1/8"]
42[15/8"]
42 [1 5/8"]
3 [1/8"]
50
[2
"]
70.7[23/4"]
35[13/8"]
100 [3 7/8"]
258.5[101/8"]
36
1
[1
'-2
1/
4"
]
45°
42 [1 5/8"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7982-C
ST6.3(No14)
DIN7982-C
ST6.3(No14)
DIN7982-C
2 Screws per Slat
M10 Bolt Set
35 x3mm (1 3
8'' x 1
8'')
Aluminum
plate pre-connected to slats
Wood blocks from steel stud to steel stud
designed, supplied and installed by others
Blocking and steel studs
to able to support
the following factored loads:
Vert.= 0.7 kN (downwards)
Hor.= 1.7 kN (inward or outward)
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
50x50x3
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
3mm aluminum plate
both sides
Aluminum slat
2''x4''x1/8''
Nut & 25mm Dia
Washer
50x110x3 SS Angles
min 38 mm
18
[3/4"]
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
SD-08
Section Detail (MP5 Screen)
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
Project ID 15124.03
REFERENCE DRAWINGS
01/B9-GA9
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
01 16 May 2018 Issued For Approval
50[2"]
3 [1/8"] 50 [2"] 305.6 [1']
50[2"]35[13/8"]386.5[1'-31/4"]50[2"]50[2"]35[13/8"]50[2"]50[2"]
571.5[1'-101/2"]
255.6 [10 1/8"] 50 [2"]
57.2 [2 1/4"]28.4 [1 1/8"]100.8 [4"]
200[77/8"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
M10 Bolt Set
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
50x50x3
50x110x3 SS Angles
3mm aluminum plate
both sides
Aluminum Tube
2"x2"x1/8"
3 layers 3/4" FR plywood fasten together
with 2 - #8 x 2" long wood screws at 12" oc
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
688.8 [2'-3 1/8"] to Grid Line UU.9
UU.9
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
100 [3 7/8"]
50 [2"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
50x50x3
3mm aluminum plate
both sides
Aluminum Tube
2"x2"x1/8"
50.8 [2"] 10 [3/8"]49.2 [1 7/8"]
M10 threaded rod w/
nut and 25mm Dia. washer
Steel Studs to be designed to support
the following factored load at anchor
locations
Vert. = 0.7 kN (Downwards)
Hor. = 1.7 (Inward or Outward)
Aluminum Holding Plate
20mm Dia.
6mm thick
Aluminum Holding Plate
20mm Dia.
6mm thick
(Identical to the one used in TPO phase 1)
(Identical to the one used in TPO phase 1)
(MP4)
3mm Perforated Aluminum Sheet
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 03 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
SD - 19
Section Detail
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/2 @ ARCH C (24'' x18'')
REFERENCE DRAWINGS
A13-01, A13-01C, A13-03, A13-04, A13-08
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic
Fire Rated, 4 mm total thickness (2 layers 0.5 mm
THK. Aluminum).
-All self drilling screws to penetrate min. 3 pitches
of thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
124' - 3'' T/O FRAMING
50 [2"]304.8 [1']152.4 [6"]
3 [1/8"]
457.2 [1'-6"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
M10 Bolt Set
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
2"x6"x1/8"
50x110x3 SS Angles
3mm aluminum plate
both sides
Aluminum Tube
2"x6"x1/8"
3 layers 3/4" FR plywood fasten together
with 2 - #8 x 2" long wood screws at 12" oc
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
3mm Perforated Aluminum Sheat
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
50.8[2"]50[2"]
ST6.3(No14)
DIN7976-C
Aluminum angle
2"x6"x1/8"
508.4[1'-8"]228.6[9"]
ST6.3(No14)
DIN7976-C
Aluminum angle
2"x6"x1/8"
50.8[2"]50[2"]50.4[2"]
994.3 [3'-3 1/8"] to Grid Line V.1
Aluminum Tube
2"x6"x1/8"
M10 threaded rod w/
nut and 25 Dia. washer
Aluminum Holding Plate
20mm Dia.
6mm thick
Aluminum Holding Plate
20mm Dia.
6mm thick
Steel Studs to be designed to support
the following factored load at anchor
locations
Vert. = 0.7 kN (Downwards)
Hor. = 1.7 (Inward or Outward)
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 11 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
SD-26
Section Detail
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/16 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
A12-01, A12-01A, A12-01B, A12-03, A12-05, A12-07
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
143.4 [5 5/8"]
minimum from outer edge of wall
170 [6 3/4"]
M10 Bolt Set
9.8 [3/8"]
18.6 [3/4"]50.8 [2"]101.6 [4"]15.9 [5/8"]
15.9[5/8"]101.6[4"]50.8[2"]18.6[3/4"]
9.8[3/8"]
50.8[2"]
50.8 [2"]
305.6[1']
110[43/8"]256.2[101/8"]50[2"]3[1/8"]
50 [2"]
50[2"]
143.4[55/8"]
50[2"]127[5"]50[2"]
502 [1'-7 3/4"]
502[1'-73/4"]50.8[2"]
50.8 [2"]50 [2"]
50 [2"]
50[2"]
42[15/8"]
42 [1 5/8"]
305.6 [1']
50 [2"] 3 [1/8"]
3 [1/8"]
3 [1/8"]
42[15/8"]
42 [1 5/8"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
M10 Bolt Set
M10threadedRod
ST6.3(No14)
DIN7976-C
50x50x3
Aluminum Tube
EIFS By Others
3mm
Aluminum Angle
35 x3mm (1 3
8'' x 1
8'')
Aluminum
plate pre-connected to slats
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Wood blocks from steel stud to steel stud
designed,supplied and installed by others
Blocking and steel studs
to able to support
the following factored loads:
Vert.= 0.7 kN (downwards)
Hor.= 1.7 kN (inward or outward)
50x110x3 SS angle
(height 150mm)
50x110x3 SS angle
(height 150mm)
50x110x3 SS angle
(height 150mm)
Neutral Barrier between SS angle
and aluminum tube to avoid corrosion
Neutral Barrier between SS angle
and aluminum tube to avoid corrosion
2''x4''x 1/8'' Aluminum Slat
Nut & 25mm Dia
Washer
Aluminum U-Shaped
Cap Plate
Outside visible side of bracket
is lapped as shown -
Gastket all locations through envelope
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
PD-02
Plan Detail (Screen)
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
Project ID 15124.03
REFERENCE DRAWINGS
B9-GA8-North East
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
01 16 May 2018 Issued For Approval
127.3 [5"]
304.7 [1']
101.6[4"]
76.2 [3"]
583.3[1'-11"]
101.6 [4"]
25[1"]
151.2[6"]
25.4[1"]
50.
8[2"]
4 mm Aluminum
Composite Panel
Sheathing
by Others
Air & Moisture Barrier
by Others
Membrane on Sheathing
by Others
50.8 [2"]
101.6[4"]
126' - 7'' T/O PARAPET
126' - 5'' T/O STEEL
Seal
124' - 4'' T/O ACP ZONE
1035.3 [3'-4 3/4"] to AXIS 17C
44
[1 3/4
"]
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
Wood Blocking
by Others
Wood Blocking
by Others
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
Steel Studs by Others
(assumed 20GA. thickness
at 16'' OC.)
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
Vertical Joint Profile
Riveted on ACP
(Rivets Finish to match profiles)
Vertical Joint Profile
Riveted on ACP
(Rivets Finish to match profiles)
Trim Flashing
3mm "Z" Shape aluminum
profile
Drainage Hole @ 4' O.C.
Drainage Hole @ 4' O.C.
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B9-SD10
Section Detail (Parapet)
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/2'' = 1'' @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
01/B9-GA11
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy = 110MPa).
01 16 May 2018 Issued For Approval
44[13/4"]101.6[4"]
15[5/8"]
50.8 [2"]
15 [5/8"]
42 [1 5/8"]
50.8 [2"]
431.3 [1'-5"]
40.9[15/8"]
112.4[43/8"]
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
3mm "Z" Shape aluminum
profile
#10 Grade 410
Stainless Steel
self-drilling screw
Pressure Cap
3mm "Z" Shape aluminum
profile
Shiming
Drip Profile
Pressure cap
Drainage Hole
6x30mm
35[13/8"]
31 [1 1/4"] 487.8 [1'-7 1/4"]
Drainage Hole
6x30mm
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#8 Grade 410
Stainless Steel
self-drilling screw
@ 12" oc
#10 Grade 410
Stainless Steel
self-drilling screw
387.3[1'-31/4"]
116' - 11'' T/O PARAPET
Min. 2% Slope
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
@ 12" oc
#8 Grade 410
Stainless Steel
self-drilling screw
@ 12" oc
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
2mm "U" Shape aluminum
profile (CONTINUOUS)
4 mm Aluminum
Composite Panel (MP2)
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 03 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
SD - 21
Section Detail
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/2 @ ARCH C (24'' x18'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
A13-01, A13-01B, A13-03, A13-05, A13-09
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic
Fire Rated, 4 mm total thickness (2 layers 0.5 mm
THK. Aluminum).
-All self drilling screws to penetrate min. 3 pitches
of thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
184.1[71/4"]
31.8[11/4"]31.8[11/4"]
152.3[6"]
50.8 [2"]
FIBER CEMENT PANEL
7 1
4'' x 5
16''
OVERLAP
2mm VERTICAL ALUMINUM PROFILE
at 16'' O.C.
SHIMMING
5
8'' Fibreglass Sheathing
by Others
Air & Moisture Barrier
by Others
119' - 10'' T/O PARAPET
119' - 8'' T/O STEEL
117' - 6'' U/S DECK
422.4 [1'-4 5/8"] to AXIS SS.1
SS1
METAL FLASHING CAP
by OTHERS
CAULKING
by OTHERS
Steel Studs by Others
(assumed 20GA. thickness
at 16'' OC.)
SHIMMING
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
7.2 [9/32"]
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
2mm VERTICAL
ALUMINUM
PROFILE
at 16'' O.C.
Steel Studs by Others
(assumed 20GA. thickness
at 16'' OC.)
25[1"]7.2[1/4"]
SHIMMING
Partial
Plan Detail A
Partial
Plan Detail A
Partial Plan Detail A-A
FIBER CEMENT PANEL
7 1
4'' x 5
16''
FIBER CEMENT PANEL
7 1
4'' x 5
16''
5
8'' Fiberglass
Sheathing
by Others
Air & Moisture
Barrier
by Others
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE
SD-04
Section Detail (Parapet)
1/2'' = 1'' @ ARCH C (24'' x18'')
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
Project ID 15124.03
REFERENCE DRAWINGS
KEY PLAN
01/B9-GA5
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy = 110MPa).
01 16 May 2018 Issued For Approval
33 [1 1/4"]
33 [1 3/8"]
33[11/4"]
33[13/8"]
31 [1 1/4"]
31[11/4"]
31 [1 1/4"]
31[11/4"]
44 [1 3/4"]
25[1"]
222[83/4"]
243 [9 5/8"]
51 [2"]
50.8[2"]
50.8 [2"]
50.8[2"]
Sheathing
by Others
Sheathing
by Others
Sheathing
by Others
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
4 mm Aluminum
Composite Panel
MP2
4 mm Aluminum
Composite Panel
MP1
4 mm Aluminum
Composite Panel MP1
4 mm Aluminum
Composite Panel MP1
482[1'7'']toGridLine18.2
1068 [3' 6''] to Grid Line VV.4
LePage PL9000
construction adhesive,
refer to GA03 & GA04 for
panel locations
DATE
DRAWING NUMBER
DRAWING TITLE
VE
VERSION DATE DESCRIPTION
00 03 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 151
PD-05
Plan Detail
DRAWN by S.F. CHECKED b
TORONTO PREMIUM OUTLETS (Phase
1/2 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
A13-01, A13-01A, A13-03, A13-05, A13-09, A1
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TR
CONSTRUCTION - MANAGEMENT
BROCCOLIN
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIV
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpo
Rated), Kynar 500 / Hylar 500 – Slate Grey - Sm
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpo
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpo
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, C
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58%
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpo
Fire Rated), Kynar 500 / Hylar 500 – Custom C
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 853
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis
Design Allura Stained Lap Siding, Traditional Ce
Texture, Colour Maple
20 Jul 2018
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectu
drawings and GC/Framing
-All composite aluminum panels to be by Alp
Fire Rated, 4 mm total thickness (2 layers 0.
THK. Aluminum).
-All self drilling screws to penetrate min. 3 pi
of thread into steel member., min. edge dista
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063
(Fy = 110MPa).
-All Stainless steel components to be grade 3
(Fy = 207MPa).
-All aluminum extrusion carrier components
min. 2mm thick and grade 6063 T5 (Fy=110
-LePage construction adhesive to be applied
cured as per manufacturers instructions.
-Dimensions to be verified on site
52013-2018
Assignment of:
-New Aluminum Cladding System
development (H-2040)
-Tender Stage Estimation
-Shop Drawings
-Bill of Materials
-Fabrication Drawings
-Installation Drawings
Scope of Work:
-Ceramic Panels Cladding
-Enamel Porcelain Panels Cladding
-Stainless Steel Panels Cladding
HIGHWAY
407
STATION
Toronto, Canada
0 1 2m
S7S6S5
198.60 FINISH BUS TERMINAL
FLOOR
FINISH ENTRANCE
FLOOR
193.35
+189.07 FINISH WEST
CONCOURSE FLOOR
WEST CONCOURSE
UNPAID AREA
SOUTH WING INTERNAL
BUS TERMINAL
ESCALATOR
NOSING LINE
BEYOND
SS ESCALATOR
BALUSTRADE
BEYOND - BY
ESCALATOR
CONTRACTOR
ESCALATOR 8 BEYOND
5338
1200
PORCELAIN ENAMEL PANELS TO
BE 1220 A.F.F. MIN. AT STAIR
12/13 LANDINGS
PORCELAIN
ENAMEL PANELS
01
SD-02
DECORATIVE GLASS
8625 8746 3709
S8 S9
(OHLFCCjv)
(OHLFCCjv)
1ESCALATORS 5 & 6 ELEVATION
PARTIAL STAIR 12 & 13 SECTION
01
S-02
02
S-02
see P01
2350619
619
619 619
619 619
619
619
1766
1806
1806
1806
1506
1142
850
SECTIONTURNLINE
191.214
1000
F.F. LEVEL
03
S-02
130
150°
6909
1025
150
±465
PORCELAIN
ENAMEL PANELS
(see 01/S-04)
SIDEWALL STEP LIGHT
300x150mm (OHLFCCjv)
(Centered Horizontally on Panels)
1025
HANDRAIL
(OHLFCCjv)
150°
150°
150°
619
1415
50
1068
1431
2400
619 619
619
619 619
1220
50
619
619
619
1050
150
619
10
10
10
275
260
Architectural
REV. A
REV. B
NOTES:
DESIGN DATE :
-
--
ARCHITECTURAL
TORONTO-
SPANDINA SUBWA
HIGHWAY 407
Project Title:
Scale : nts
EF Project No: 1302
-Ref. dwg No:A33-1-A7313
Drawing T
Escalator 5 & 6
partial stair 12 &
Product: Porcelain Enam
Section: 07 44 16
Name of product: PEP S
Sheet manufacturer: 1mm
Contract Number: A35-2
LEGEND:
* The dimensions of stainless
substructure will be verified an
to the heavy substructure's fin
1. Porcelain Enamel Panel
2. a. Stainless steel Clip ,type
22x12x1.27mm (part len
b. Stainless steel Clip,type
15x12x1.27mm (part len
c. Stainless steel Clip,type
34x12x1.27mm (part len
3. Stainless steel angle 20x2
4. a. Steel Studs 50x35x1mm
b. Steel Studs 70x35x1mm
5. Screw ST4.2 (No8) stainle
6. HILTI Kwik Flex Screw#10
UCAN fasteners TRH 1034
7. Rivet No4 stainless steel D
8. Backer Rod
9. Sealant (to be tooled to co
10. Stainless Steel Edge Trim
-All dimensions are in mm
on site before fabrication
-Stainless steel clips are to
o.c. vertically and horizon
perimeter of each porcelai
-Porcelain enamel panel w
-Min. 2 #8 screws per stain
steel stud.
-Before to begin works, coo
Structural Subcontractor, C
system, escalators, art glas
lighting system, terrazzo ba
will be necessary.
2
50.0
50 mm10
20 100
10010
14
1750
35
01DETAIL SECTION
67
8
9
5
4a
1
2b
7
2b
171
100
02DETAIL SECTION
50
35
15
68
2
50.0
50 mm10
20 100
1
2b
4a
6
Foam tape
DETAIL SECTION
03DETAIL SECTION
76
15
67
50
100
6
2
50.0
50 mm10
20 100
1
2b
4a
6
DETAIL SECTION
10
100
50
18
15
67
2
50.0
5010
20
1
4a
2b
7
9
8
2b
DETAIL SECTION
10
18
15
68
50
2
50.0
50 mm10
20 100
2b
1
5
9
8
01SECTION
ESCALATOR SIDE CLADDING AT TERRAZZO BASE 0 100 200mm see E-01
20
10
35
152
10
35
38
35
35
50
76
20
7038
35
100
100
100
varies
45
150
1025
02
SD-02
03
SD-02
TERRAZZO
FINISH
(OHLFCCjv)
4b
4a
1 2a
9
10
Handrail
(OHLFCCjv)
SS Panels
(OHLFCCjv)
02SECTION
ESCALATOR SIDE CLADDING AT TERRAZZO BASE 0 100 200mm see E-01
TERRAZZO
FINISH
(OHLFCCjv)
20
100
150
152
10
35
45
varies
7038
35
100
04
SD-02
1
4b
2a
10
9
Handrail
(OHLFCCjv)
SS Panels
(OHLFCCjv)
Galvanized Steel Angle
76x76x6.4mm
(OHLFCCjv)
BICYCLE CURB SEC
TYPICAL AT ESCALATOR BALUSTRADE
152
10
35
45
7038
35
100
20
100
1806
Handrail
(OHLFCCjv)
9
10
2a
1
70
35
38
6
Galvanized Steel An
76x76x6.4mm
(OHLFCCjv)
OUTLINE OF
HANDRAIL BEHIND
OHLFCCjv
OUTLINE OF FLEXIBLE
ESCALATOR HANDRAIL (OHLFCCjv)
10
619
10
618
2
50.0
50 mm10
20 100
100 100
100
70 35
35 5035
4b 5
9
8
3
1
2
50.0
50 mm10
20 100
10010
14
1750
35
01DETAIL SECTION
67
8
9
5
4a
1
2b
7
2b
171
100
02DETAIL SECTION
50
35
15
68
2
50.0
50 mm10
20 100
1
2b
4a
6
Foam tape
DETAIL SECTION
03DETAIL SECTION
76
15
67
50
100
6
2
50.0
50 mm10
20 100
1
2b
4a
6
DETAIL SECTION
10
100
50
18
15
67
2
50.0
5010
20
1
4a
2b
7
9
8
2b
DETAIL SECTION
10
18
15
68
50
35
2
50.0
50 mm10
20 100
2b
1
4
5
9
8
2
50.0
50 mm10
20 100
10010
14
1750
35
01DETAIL SECTION
67
8
9
5
4a
1
2b
7
2b
171
100
02DETAIL SECTION
50
35
15
68
2
50.0
50 mm10
20 100
1
2b
4a
6
Foam tape
DETAIL SECTION
03DETAIL SECTION
76
15
67
50
100
6
2
50.0
50 mm10
20 100
1
2b
4a
6
04DETAIL SECTION
10
100
50
18
15
67
2
50.0
50 mm10
20 100
1
4a
2b
7
9
8
2b
05DETAIL SECTION
10
18
15
68
50
35
2
50.0
50 mm10
20 100
2b
1
4a
5
9
8
2
50.0
50 mm10
20 100
10010
14
1750
35
01DETAIL SECTION
67
8
9
5
4a
1
2b
7
2b
171
100
02DETAIL SECTION
50
35
15
68
2
50.0
50 mm10
20 100
1
2b
4a
6
Foam tape
DETAIL SECTION
03DETAIL SECTION
76
15
67
50
100
6
2
50.0
50 mm10
20 100
1
2b
4a
6
04DETAIL SECTION
10
100
50
18
15
67
2
50.0
50 mm10
20 100
1
4a
2b
7
9
8
2b
05DETAIL SECTION
10
18
15
68
50
35
2
50.0
50 mm10
20 100
2b
1
4a
5
9
8
2
50.0
50 mm10
20 100
10010
14
1750
35
01DETAIL SECTION
67
8
9
5
4a
1
2b
7
2b
171
100
02DETAIL SECTION
50
35
15
68
2
50.0
50 mm10
20 100
1
2b
4a
6
Foam tape
DETAIL SECTION
03DETAIL SECTION
76
15
67
50
100
6
2
50.0
50 mm10
20 100
1
2b
4a
6
04DETAIL SECTION
10
100
50
18
15
67
2
50.0
50 mm10
20 100
1
4a
2b
7
9
8
2b
05DETAIL SECTION
10
18
15
68
50
35
2
50.0
50 mm10
20 100
2b
1
4a
5
9
8
ENAMEL
DETAILS - E.A.S.
PLAN
PLAN
DETAIL
481064825
25
695
CLEAROPENING
300
MASONRY OPENING
280
INSIDE ENCLOSURE
265
RECESS
100
5
10550
25
60 80
TRIP
SWITCH
01
01
63
63
45
280
DOOR WIDTH
LOCATEDOORSTOP
TOSUITDOORIN
CLOSEPOSITION
50
SECTION - E.A.S.
250
OUTSIDEENCLOSURE
675
INSIDEMAINENCLOSURE
300
PANEL
240
TRIPSWITCHOPNG.
3030
375
TELEPHONECABINETD00R
2070
TOFIN.FLR.
265
RECESS
03
03
02B
02A
02C
02B
02A
02C
150
300
MASONRY OPENING
280
INSIDE ENCLOSURE
250
OUTSIDEENCLOSURE
10
16
25
PLYWOOD SPACERS
(OHLFCCjv)
SS TEL.MOUNTING
BOARDSUPPORT
ANGLE (OHLFCCjv)
TEL.MOUNTING
BOARD (OHLFCCjv)
SS DOOR W/CONCEALED
SS PIANO HINGE
(OHLFCCjv)
1.6THK SS ENCLOSURE
(OHLFCCjv)
50
180
TO BACK OF BOARD
TRIP SWITCH
MOUNTING BRACKETS
(OHLFCCjv)
1
2
4
5
CONC STRUCTURE/
MASONRY WALL1
48X32X1061 DIA SS FIN.
RING,CUT OPENING IN
WALL FINISH TO FIT
PLYWOOD SHIMS,
AS REQ.
(OHLFCCjv)
PLYWOOD SPACER
AS REQ.
(OHLFCCjv)
1.6THK. SS ENCLOSURE
SECURED TO BACK
WALL PROVIDE
FASTENERS.(OHLFCCjv)
25x20x365LG
x1.6THK SS DOOR
STOP (1-OFF) FASTEN
TO INSIDE
OF MAIN ENCLOSURE
275W x355H x 20THK
TELEPHONE MOUNTING
BOARD TO SUPPORT
ANGLES (OHLFCCjv)
225 x 25 x 300LG x
1.6 THK SS PHONE
BOARD SUPPORT ANGLE
(2-OFF) FASTEN TO BOTH
SIDES (INSIDE OF MAIN
ENCLOSURE) (OHLFCCjv)
400
1010
PLYWOOD SPACERS
(OHLFCCjv)
125 x 45 OPENING
TOP & BOTTOM OF
ENCLOSURE
(OHLFCCjv)
100 x50 X260LG
1.6THK SS MOUNTING
BTACKET WELDED TO
BOTH SIDES (INSIDE)
ENCLOSURE (OHLFCCjv)
280W x 300H x 1.6THK
SS PANEL W/ CUT TO
SUIT TRIP SWITCH 25 SELF
FLANGE (INTERNAL) ALL
AROUND PANEL, WELD PANEL
TO MAIN ENCLOSURE
(OHLFCCjv)
1
1
02 01
1
695
RECESS
160
2070TOFIN.FLOOR
1060TOFINFLR.
DETAILS - E.A.S. 03
SS TELEPHONE
CABINET
(OHLFCCjv)
240
2
8
11
5
8
11
5
Design loads (internal & external
panels)
Wind loads: 1.25kPa positive
and negative pressure.
Dead loads: 0.313kPa (Ceramic
Panel).
Material properties
Ceramic panels as per AGROB
BUCHTAL Manufacturer Specs.
Stainless steel type 304: yield
strength 210 Mpa.
(Shapes: ASTM A276,
Sheet & Plate: ASTM A666)
180
1
CONCRETE
OR CMU WALL
CLADDING CORNER-SECTION S3
1
2
8
4
5
14
180
8
180
4
5
11
3
2
11
1
1200
1192
10
CLADDING SECTION AA(P3)
CLADDING DETAIL FOR 1200mm TILES PLAN - P3
A
A
CONCRETE
OR CMU WALL
8 8
200
12
10
200
8
150
2
11
1
CONCRETE
OR CMU WALL
CLADDING CORNER-SECTION S3a
90.0°
150
EXTERNAL CORNER- PLAN
EXTERNAL CORNER- PLAN
180
11
2
11
8
11
STAINLESS STEEL
ANGLE (CONTINUOUS)
120x120x1.35mm
90.0°
19
19
CLADDING CORNER-SECTION S2
INTERNAL CORNER- PLAN
SHIM
AS
REQ.
SHIM
AS
REQ.
STAINLESS STEEL
ANGLE (PART 100mm)
120x120x2.75mm
STAINLESS STEEL
ANGLE (CONTINUOUS)
100x100x1.35mm
STAINLESS STEEL
ANGLE (PART 100mm)
120x120x2.75mm
150
typ.
150
typ.
90.0°
continuous angle
120x120mm
16
16
120x120mm
CONCRETE WALL
R15
8
4
5
11
2
1
16
9
19
1313
1313
13 13
1313
13
13
13
10.0°
CLADDING CORNER-SECTION
INTERNAL CORNER- PLAN (CONCAVE WALL)
13
8
4
5
1111
11
2
1
19
Architectural Drawing
REV. A
REV. B
NOTES:
DESIGN DATE : 08 AUG 2014
- -/-/-
-- --/--/--
ELEGANT FACADE INC.
ARCHITECTURAL SOLUTIONS
TORONTO-YORK
SPANDINA SUBWAY EXTENSION
HIGHWAY 407 STATION
Project Title:
Scale : nts
EF Project No:1302
Drawing Title :
Generic Details 03
Ceramic Tile Panel system
Dwg No: GD-05
Product: Ceramic Tile Panel System
Section: 09 35 00
Contract Number: A35-26
Name of product: AGROB BUCHTAL K-20 SYSTEM
Tile manufacturer: 20mm AGROB BUCHTAL
Design loads
Wind loads: 1.25kPa positive and negative pressure.
Dead loads: 0.313kPa (Ceramic Panel).
Material properties
Ceramic panels as per AGROB BUCHTAL Manufacturer Specs.
Stainless steel type 304: yield strength 210 Mpa.
(Shapes: ASTM A276, Sheet & Plate: ASTM A666)
-Ref. dwg No:A33-1-A9101 Sh No: 319
-All dimensions are in mm and will be check on site
before fabrication.
-Before to begin works coordination between
Structural Subcontractor,Ceramic panel tile
system and M&E will be necessairy.
-All wall brackets are to be spaced at 700mm
o.c. vertically.
-Classic system rail K20 to be fastened to
vertical subgirt with 2#rivets 4x10 mm at 300mm o.c.
-For every continuous vertical subgirt, place two rivets
through the round holes at the lower bracket. At the
rest brackets place 2 rivets through the oval holes.
* The dimensions of stainless steel parts will be verified &
adjusted according to the substructure's final edge.
1. Ceramic Panel Tile System Agrob Buchtal 20mm
2. Classic System Rail K20 (Agrob)
3. Stainless steel joint profile thickness 0.7mm
4. Wall bracket,stainless steel angle* type"L"
thickness 2.75mm
5. Stainless Steel vertical subgirt continuous angle*
thickness 1.35mm
6. Stainless steel perimeter frame with thickness
0.7mm,shapes & dimensions varies
7. Stainless steel clip for perimeter frame
8. a.For concrete: Hilti Exp. anchor KB3 3/8" x 3" LT
stainless steel #304 / ITW or equal
b. For masonry block: Hilti Sleeve anchor HLC-HX
3/8" x 1-7/8" stainless steel / ITW or equal
9. Tek screw 1/4'' x 1 3/4''
10.Screw ST 4.2(No8) DIN7981C stainless steel
11.Rivet No4 DIN 7337 stainless steel
12.Hexagon bolt M10 stainless steel L:60mm with
hexagon nut.
13.Bituminous paint: "Mel Roll" or equal
14.Reserved
15.Lexcor Air Vapour Barrier
16.Stainless steel part* thk.0.70mm
17.Reserved
18.Insulation:Mineral Fiber Board Roxul RXL60@96Kg/m3
19.Stainless steel corner trim
20.Perforated Ceramic Tile System Agrob Buchtal 20mm,
including acoustic backing
LEGEND:
SECTION-DETAIL
see P13,P13A
01
CERAMIC PANEL AT PLATFORM LEVEL ESCALATOR SUPPORT WALLS
CONCRETE WALL OR
CONC. BLOCK WALL STRUCTURAL
ANGLE
(OHLFCCjv)
1
TYPICAL HYDRANT
FIXTURE (OHLFCCjv)
SECTION-DETAIL
see E11
02
RECESSED HYDRANT
03
RECESSED LIGHT FITTING - SECTION- TYP. see E-17
SECTION DETAIL
1
2
8
4
5
LIGHT FITTING
(OHLFCCjv)
CONCRETE
OR CMU WALL
04
S-28(1)
280
10
180
1010
120
6
400
170
100
150
124
300
VARIES
20
6550235
350
SATIN SS PANEL
SYSTEM, FIXED ON
50MM HSS FRAME
(OHLFCCjv)
20
180
10
8
11
4
5
2
1
11
SECTION-DETAIL
see E30
04
6 13
84
13
13
CONCRETE WALL
(ESCALATOR SUPPORT)
CONCRETE
BLOCK WALL
1
2
45
8
11
150
150
624
632
150
typ.
13
3
81* 484
SECTION-DETAIL see P13,P13A
05
CERAMIC PANEL AT PLATFORM LEVEL ESCALATOR SUPPORT WALLS
8
8
8
9
Architectural Drawing
REV. A
REV. B
NOTES:
DESIGN DATE : 20 Nov 2014
- -/-/-
-- --/--/--
ELEGANT FACADE INC.
ARCHITECTURAL SOLUTIONS
TORONTO-YORK
SPANDINA SUBWAY EXTENSION
HIGHWAY 407 STATION
Project Title:
Scale : nts
EF Project No :1302
-Ref. dwg No:A33-1-A9101 Sh No: 319
Drawing Title :
Interior section details
Dwg No: S-20
Product: Ceramic Tile Panel System
Section: 09 35 00
Contract Number: A35-26
Name of product: AGROB BUCHTAL K-20 SYSTEM
Tile manufacturer: 20mm AGROB BUCHTAL
-Ref. dwg No:A33-1-A9105 Sh No: 323
-Ref. dwg No:A33-1-A9155 Sh No: 334
-Ref. dwg No:A33-1-A9157 Sh No: 336
-All dimensions are in mm and will be check on site
before fabrication.
-Before to begin works coordination between
Structural Subcontractor,Ceramic panel tile
system and M&E will be necessairy.
-All wall brackets are to be spaced at 700mm
o.c. vertically.
-Classic system rail K20 to be fastened to
vertical subgirt with 2#rivets 4x10 mm at 300mm o.c.
-For every continuous vertical subgirt, place two rivets
through the round holes at the lower bracket. At the
rest brackets place 2 rivets through the oval holes.
* The dimensions of stainless steel parts will be verified &
adjusted according to the substructure's final edge.
1. Ceramic Panel Tile System Agrob Buchtal 20mm
2. Classic System Rail K20 (Agrob)
3. Stainless steel joint profile thickness 0.7mm
4. Wall bracket,stainless steel angle* type"L"
thickness 2.75mm
5. Stainless Steel vertical subgirt continuous angle*
thickness 1.35mm
6. Stainless steel perimeter frame with thickness
0.7mm,shapes & dimensions varies
7. Stainless steel clip for perimeter frame
8. a.For concrete: Hilti Exp. anchor KB3 3/8" x 3" LT
stainless steel #304 / ITW or equal
b. For masonry block: Hilti Sleeve anchor HLC-HX
3/8" x 1-7/8" stainless steel / ITW or equal
9. Tek screw 1/4'' x 1 3/4''
10.Screw ST 4.2(No8) DIN7981C stainless steel
11.Rivet No4 DIN 7337 stainless steel
12.Hexagon bolt M10 stainless steel L:60mm with
hexagon nut.
13.Bituminous Paint: "Mel-Roll LM" or equal
14.Reserved
15.Lexcor Air Vapour Barrier
16.Stainless steel part* thk.0.70mm
17.Reserved
18.Insulation:Mineral Fiber Board Roxul RXL60@96Kg/m3
19.Stainless steel corner trim
20.Perforated Ceramic Tile System Agrob Buchtal 20mm,
including acoustic backing
LEGEND:
Design loads (internal & external
panels)
Wind loads: 1.25kPa positive and
negative pressure.
Dead loads: 0.313kPa (Ceramic
Panel).
Material properties
Ceramic panels as per AGROB
BUCHTAL Manufacturer Specs.
Stainless steel type 304: yield
strength 210 Mpa.
(Shapes: ASTM A276,
Sheet & Plate: ASTM A666)
CERAMICS
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects
2019 02 portfolio_projects

More Related Content

What's hot

7220 CASE IH Magnum tractor (North America) parts catalog
7220 CASE IH Magnum tractor (North America) parts catalog7220 CASE IH Magnum tractor (North America) parts catalog
7220 CASE IH Magnum tractor (North America) parts catalogPartCatalogs Net
 
Kubota kx41 2 excavator parts catalogue manual
Kubota kx41 2 excavator parts catalogue manualKubota kx41 2 excavator parts catalogue manual
Kubota kx41 2 excavator parts catalogue manualfjsekksmemm
 
SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...
SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...
SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...SunMaxx Solar
 
Simon Lighting Light Points - Uno#
Simon Lighting Light Points - Uno#Simon Lighting Light Points - Uno#
Simon Lighting Light Points - Uno#Mktlighting
 
Whitefriars Presentation 2 A1
Whitefriars Presentation 2 A1Whitefriars Presentation 2 A1
Whitefriars Presentation 2 A1Vincent Doherty
 
Yale b974 gdp50 lx lift truck service repair manual
Yale b974 gdp50 lx lift truck service repair manualYale b974 gdp50 lx lift truck service repair manual
Yale b974 gdp50 lx lift truck service repair manualdfjjsekksekmsw
 
Yale b974 glp060 lx lift truck service repair manual
Yale b974 glp060 lx lift truck service repair manualYale b974 glp060 lx lift truck service repair manual
Yale b974 glp060 lx lift truck service repair manualfuhsejskekmmm
 
YALE B974 GDP20LX LIFT TRUCK Service Repair Manual
YALE B974 GDP20LX LIFT TRUCK Service Repair ManualYALE B974 GDP20LX LIFT TRUCK Service Repair Manual
YALE B974 GDP20LX LIFT TRUCK Service Repair Manualeidkmm fksemm
 
Yale b974 glp20 lx lift truck service repair manual
Yale b974 glp20 lx lift truck service repair manualYale b974 glp20 lx lift truck service repair manual
Yale b974 glp20 lx lift truck service repair manualfjjskekmdmme
 

What's hot (14)

Sectional Door System
Sectional Door SystemSectional Door System
Sectional Door System
 
7220 CASE IH Magnum tractor (North America) parts catalog
7220 CASE IH Magnum tractor (North America) parts catalog7220 CASE IH Magnum tractor (North America) parts catalog
7220 CASE IH Magnum tractor (North America) parts catalog
 
Kubota kx41 2 excavator parts catalogue manual
Kubota kx41 2 excavator parts catalogue manualKubota kx41 2 excavator parts catalogue manual
Kubota kx41 2 excavator parts catalogue manual
 
SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...
SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...
SunMaxx Installation Manual - TitanPower ALDH29 Flat Plate Collector - Flush ...
 
Simon Lighting Light Points - Uno#
Simon Lighting Light Points - Uno#Simon Lighting Light Points - Uno#
Simon Lighting Light Points - Uno#
 
Whitefriars Presentation 2 A1
Whitefriars Presentation 2 A1Whitefriars Presentation 2 A1
Whitefriars Presentation 2 A1
 
Cuadernillo no 5
Cuadernillo no 5Cuadernillo no 5
Cuadernillo no 5
 
Cuadernillo no 4
Cuadernillo no 4Cuadernillo no 4
Cuadernillo no 4
 
Pharma caem caem uk eng
Pharma caem caem uk  engPharma caem caem uk  eng
Pharma caem caem uk eng
 
The specs of container house
The specs of container houseThe specs of container house
The specs of container house
 
Yale b974 gdp50 lx lift truck service repair manual
Yale b974 gdp50 lx lift truck service repair manualYale b974 gdp50 lx lift truck service repair manual
Yale b974 gdp50 lx lift truck service repair manual
 
Yale b974 glp060 lx lift truck service repair manual
Yale b974 glp060 lx lift truck service repair manualYale b974 glp060 lx lift truck service repair manual
Yale b974 glp060 lx lift truck service repair manual
 
YALE B974 GDP20LX LIFT TRUCK Service Repair Manual
YALE B974 GDP20LX LIFT TRUCK Service Repair ManualYALE B974 GDP20LX LIFT TRUCK Service Repair Manual
YALE B974 GDP20LX LIFT TRUCK Service Repair Manual
 
Yale b974 glp20 lx lift truck service repair manual
Yale b974 glp20 lx lift truck service repair manualYale b974 glp20 lx lift truck service repair manual
Yale b974 glp20 lx lift truck service repair manual
 

Similar to 2019 02 portfolio_projects

SEPCO Steel Electric Conduit & Cable Fittings - Service Entrance Fittings
SEPCO Steel Electric Conduit & Cable Fittings - Service Entrance FittingsSEPCO Steel Electric Conduit & Cable Fittings - Service Entrance Fittings
SEPCO Steel Electric Conduit & Cable Fittings - Service Entrance FittingsThorne & Derrick International
 
SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs
SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs
SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs Thorne & Derrick International
 
ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL
ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL
ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL GajananTodeti
 
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical EnclosuresCe-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical EnclosuresThorne & Derrick International
 
EJOfast Stitching Screw
EJOfast Stitching ScrewEJOfast Stitching Screw
EJOfast Stitching ScrewNathan Handley
 
Gam ekm_Spec Sheet
Gam ekm_Spec SheetGam ekm_Spec Sheet
Gam ekm_Spec SheetElectromate
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Royal Museum Alor Setar
Royal Museum Alor SetarRoyal Museum Alor Setar
Royal Museum Alor Setarshacjhow
 
Measured drawings
Measured drawingsMeasured drawings
Measured drawingsjiuaN59
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...fujsked9dik
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...f8uedkdm3e4r
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...jdjskdkdmmd
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...tus0573581
 
Traction tread-safety-gratings
Traction tread-safety-gratingsTraction tread-safety-gratings
Traction tread-safety-gratingsJack Cui
 
ALUMINIUM BUTTERFLY VALVE
ALUMINIUM BUTTERFLY VALVEALUMINIUM BUTTERFLY VALVE
ALUMINIUM BUTTERFLY VALVEregentvalve
 

Similar to 2019 02 portfolio_projects (20)

SEPCO Steel Electric Conduit & Cable Fittings - Service Entrance Fittings
SEPCO Steel Electric Conduit & Cable Fittings - Service Entrance FittingsSEPCO Steel Electric Conduit & Cable Fittings - Service Entrance Fittings
SEPCO Steel Electric Conduit & Cable Fittings - Service Entrance Fittings
 
Products of DIMEX 2022.pdf
Products of DIMEX 2022.pdfProducts of DIMEX 2022.pdf
Products of DIMEX 2022.pdf
 
SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs
SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs
SEPCO Steel Electric Conduit & Cable Fittings - EMT Fititngs
 
ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL
ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL
ALUMINIUM SLIDING WINDOWS AND WINDOW GRILL
 
2935 0095 20_airnet_catalog_lo_res
2935 0095 20_airnet_catalog_lo_res2935 0095 20_airnet_catalog_lo_res
2935 0095 20_airnet_catalog_lo_res
 
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical EnclosuresCe-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
 
Camlock Coupling Manufacturers
Camlock Coupling ManufacturersCamlock Coupling Manufacturers
Camlock Coupling Manufacturers
 
EJOfast Stitching Screw
EJOfast Stitching ScrewEJOfast Stitching Screw
EJOfast Stitching Screw
 
Gam ekm_Spec Sheet
Gam ekm_Spec SheetGam ekm_Spec Sheet
Gam ekm_Spec Sheet
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Rammer e 68
Rammer e 68Rammer e 68
Rammer e 68
 
Royal Museum Alor Setar
Royal Museum Alor SetarRoyal Museum Alor Setar
Royal Museum Alor Setar
 
Measured drawings
Measured drawingsMeasured drawings
Measured drawings
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
 
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
JCB 3CX SUPER PS BACKOHE LOADER Parts Catalogue Manual (Serial Number 0093000...
 
GS
GSGS
GS
 
Traction tread-safety-gratings
Traction tread-safety-gratingsTraction tread-safety-gratings
Traction tread-safety-gratings
 
ALUMINIUM BUTTERFLY VALVE
ALUMINIUM BUTTERFLY VALVEALUMINIUM BUTTERFLY VALVE
ALUMINIUM BUTTERFLY VALVE
 

Recently uploaded

SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxjanettecruzeiro1
 
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai Doux
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai DouxDubai Call Girls Pro Domain O525547819 Call Girls Dubai Doux
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai Douxkojalkojal131
 
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130Suhani Kapoor
 
Stark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptxStark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptxjeswinjees
 
Verified Trusted Call Girls Adugodi💘 9352852248 Good Looking standard Profil...
Verified Trusted Call Girls Adugodi💘 9352852248  Good Looking standard Profil...Verified Trusted Call Girls Adugodi💘 9352852248  Good Looking standard Profil...
Verified Trusted Call Girls Adugodi💘 9352852248 Good Looking standard Profil...kumaririma588
 
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...home
 
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️soniya singh
 
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...ranjana rawat
 
Kurla Call Girls Pooja Nehwal📞 9892124323 ✅ Vashi Call Service Available Nea...
Kurla Call Girls Pooja Nehwal📞 9892124323 ✅  Vashi Call Service Available Nea...Kurla Call Girls Pooja Nehwal📞 9892124323 ✅  Vashi Call Service Available Nea...
Kurla Call Girls Pooja Nehwal📞 9892124323 ✅ Vashi Call Service Available Nea...Pooja Nehwal
 
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130  Available With RoomVIP Kolkata Call Girl Gariahat 👉 8250192130  Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Roomdivyansh0kumar0
 
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...Call Girls in Nagpur High Profile
 
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...Suhani Kapoor
 
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...Call Girls in Nagpur High Profile
 
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiVIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiSuhani Kapoor
 
SCRIP Lua HTTP PROGRACMACION PLC WECON CA
SCRIP Lua HTTP PROGRACMACION PLC  WECON CASCRIP Lua HTTP PROGRACMACION PLC  WECON CA
SCRIP Lua HTTP PROGRACMACION PLC WECON CANestorGamez6
 
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)amitlee9823
 
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130Suhani Kapoor
 
Fashion trends before and after covid.pptx
Fashion trends before and after covid.pptxFashion trends before and after covid.pptx
Fashion trends before and after covid.pptxVanshNarang19
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiSuhani Kapoor
 

Recently uploaded (20)

SD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptxSD_The MATATAG Curriculum Training Design.pptx
SD_The MATATAG Curriculum Training Design.pptx
 
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai Doux
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai DouxDubai Call Girls Pro Domain O525547819 Call Girls Dubai Doux
Dubai Call Girls Pro Domain O525547819 Call Girls Dubai Doux
 
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
VIP Call Girls Service Mehdipatnam Hyderabad Call +91-8250192130
 
Stark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptxStark Industries Marketing Plan (1).pptx
Stark Industries Marketing Plan (1).pptx
 
Verified Trusted Call Girls Adugodi💘 9352852248 Good Looking standard Profil...
Verified Trusted Call Girls Adugodi💘 9352852248  Good Looking standard Profil...Verified Trusted Call Girls Adugodi💘 9352852248  Good Looking standard Profil...
Verified Trusted Call Girls Adugodi💘 9352852248 Good Looking standard Profil...
 
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
Recommendable # 971589162217 # philippine Young Call Girls in Dubai By Marina...
 
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
Call Girls in Kalkaji Delhi 8264348440 call girls ❤️
 
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
(AISHA) Ambegaon Khurd Call Girls Just Call 7001035870 [ Cash on Delivery ] P...
 
Kurla Call Girls Pooja Nehwal📞 9892124323 ✅ Vashi Call Service Available Nea...
Kurla Call Girls Pooja Nehwal📞 9892124323 ✅  Vashi Call Service Available Nea...Kurla Call Girls Pooja Nehwal📞 9892124323 ✅  Vashi Call Service Available Nea...
Kurla Call Girls Pooja Nehwal📞 9892124323 ✅ Vashi Call Service Available Nea...
 
escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974
escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974
escort service sasti (*~Call Girls in Prasad Nagar Metro❤️9953056974
 
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130  Available With RoomVIP Kolkata Call Girl Gariahat 👉 8250192130  Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Room
 
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...Top Rated  Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
Top Rated Pune Call Girls Saswad ⟟ 6297143586 ⟟ Call Me For Genuine Sex Serv...
 
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
 
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
VVIP Pune Call Girls Hadapsar (7001035870) Pune Escorts Nearby with Complete ...
 
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service BhiwandiVIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
VIP Call Girls Bhiwandi Ananya 8250192130 Independent Escort Service Bhiwandi
 
SCRIP Lua HTTP PROGRACMACION PLC WECON CA
SCRIP Lua HTTP PROGRACMACION PLC  WECON CASCRIP Lua HTTP PROGRACMACION PLC  WECON CA
SCRIP Lua HTTP PROGRACMACION PLC WECON CA
 
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
Escorts Service Basapura ☎ 7737669865☎ Book Your One night Stand (Bangalore)
 
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
 
Fashion trends before and after covid.pptx
Fashion trends before and after covid.pptxFashion trends before and after covid.pptx
Fashion trends before and after covid.pptx
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
 

2019 02 portfolio_projects

  • 1. SKYLINE facades Tel. +30 210 4009335 www.skylinefacades.com info@skylinefacades.com 160-162, Laodikeias Street, 18451, Nikaia, Greece FACADE ENGINEERING SERVICES
  • 2. 12017-present Assignment of: -Shop Drawings -Fabrication Drawings -Installation Drawings Scope of work: -Aluminum Curtain Walls -Aluminum Doors & Windows -Aluminum Window Walls -Glass Cladding -Aluminum Fins -Aluminum Slab Covers 250 5th AVENUE New York, USA
  • 3.
  • 4. 12.7 [1/2"] Clear Opening=977.9 [3'-2 1/2"] Clear Opening=466.7 [1'-6 3/8"] 152.4[6"]171.5[63/4"] 323.8[1'-03/4"] 406.4[1'-4"] 688.7[2'-31/8"] 342.6 [1'-1 1/2"] R.O.=2827 [9'-3 1/2"] 142.4 [5 5/8"] 176.4 [7"] 1574 [5'-2"] SLAB COVER Edge Flush to Brick Wall Edge SLAB Edge SLAB COVER Edge Flush to Brick Wall Edge SLAB Edge DT-105 DT-106 sim sim DT-128 2876.6 [9'-5 1/4"] to Grid Line 3 E.O.S. 63.5 [2 1/2"] E.O.S.215.9[81/2"] 140 [5 1/2"] SLABEdge 82.6[31/4"] toGridLineE 82.6[31/4"] GL2 GL1 GL1 GL1A GL1A GL1 GL1A T.O.S. 14TH FL 126' - 10" T.O.S. 15TH FL 136' - 1" R.O.=2591[8'-6"] F.D.=2555[8'-45/8"] 433.1[1'-5"]60[23/8"]315[1'-03/8"]60[23/8"]315[1'-03/8"]60[23/8"]403.1[1'-37/8"]60[23/8"]409[1'-41/8"] BrickWallEdgeBeyond GL2GL2 457.2[1'-6"]1676.4[5'-6"]457.2[1'-6"] R.O.=2832 [9'-3 1/2"] 2876 [9'-5 1/4"] to Grid Line 3 T.O.S.1 126' - FINEdge [03] TpN- Plan 01 scale 1/8 [01] TpN- ELEVATION scale 1/8 Max torque (Nm) 35 Max torque (Nm) 35 Maxtorque (Nm)35 Maxtorque (Nm)35 147.4 [5 3/4"] 18.3[3/4"] 10[3/8"] 7.3 [1/4"] 125.3 [4 7/8"] 46 [1 3/4"]4 [1/8"] 150[57/8"] 46 [1 7/8"] 4 [1/8"] 150[57/8"] 60[23/8"] 339.5[1'-13/8"] Transom Window Sash Window Wall Receptor Window Frame Glazing Bead Window Frame Glazing Mineral Wool Insulation 40mm Aluminum Tray 1.5mm Aluminum Sheet 2mm Aluminum Angle 20x20x2 mm Aluminum Angle 20x20x2 mm 27.1 [1 1/8"] 133 [5 1/4"] 17.3 [5/8"] T.O.S. 8TH FL 71'- 4" E 81.8 [3 1/4"] to Grid Line E Interior Floor Finishes by others 228.6[9"] Interior Floor Finishes by others 102[4"] 102 [4"] Steel Studs by others 228.6[9"] 190.5[71/2"] 63.4 [2 1/2"] Aluminum Fin 190.6 [7 1/2"] 12.7[1/2"]55[21/8"]379.7[1'-3"]19.6[3/4"]32.2[11/4"]75[3"] 58.9 [2 3/8"] 36.5 [1 3/8"] 57 [2 1/4"] 152.4 [6"] 47 [1 7/8"] 30 [1 1/8"] 135 [5 3/8"] 212 [8 3/8"] 75[3"]12.7[1/2"] Window Investment by others Line of Slab Covers Line of Vertical Fins 81.8 [3 1/4"] 152.4 [6"] 158 [6 1/4"] 14.4 [5/8"] Aluminum Angle 50X50 Aluminum Angle 50X50 Mineral Wool Insulation Concrete Anchors M10X95 Spacing TBD Waterproofing Membrane Concrete Anchors M10X95 Spacing TBD 281.4 [11 1/8"] 87.9[31/2"] 25[1"] 40 [1 5/8"] Drainage hole: 6x25mm @ 2' o.c. 2% Project IDDATE 59380 DRAWING NUMBER DRAWING TITLE DRAWN by Skyline Facades VERSION VERSION DATE DESCRIPTION CHECKED by ETEM 00 250 5th Ave Hotel - New York PROJECT TITLE OWNER CONTRACTOR ARCHITECT PROVIDER SERVICES KEY PLAN SUBCONTRACTOR Ε Μ P I R E M A N A G E M E N T The RINALDI G R O U PGENERAL FACADE SYSTEM ENGINEERING FACADE SCALE 1/2'' = 1'' @ ARCH C (24'' x18'') 28 Street 5thAvenue DT - 109 Type K - Section Detail 21 Apr 2018 Issued For Approval REFERENCE DRAWINGS TpK - GA01 SPECIFICATIONS NOTES GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Glass GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Glass GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GLASS TYPES: -Glazing Specifications as per Section 08 00 00 -Curtain Wall Specifications as per Section 08 44 13 Thermally Broken Aluminum Curtain Wall System, Powder Coating Finish -Aluminum Doors Specifications as per Section 08 41 13 Thermally Broken Aluminum Opening Doors System, Powder Coating Finish Etem Doors System E75 Etem Curtain Wall System E85 -Steel Framing, Parapet and Slab Edges Defined according to Structural Drawings -Primary units in mm Etem Window Wall System E86 01 21 Sept 2018 01 Issued For Approval21 Sept 2018 Maxtorque (Nm)35 Maxtorque (Nm)35 Max torque (Nm) 35 152.4 [6"] 50 [2"] 43[13/4"] 5[1/4"] 40[15/8"] 60[23/8"] 75[3"]32[11/4"]40[15/8"]333.9[1'-11/8"]70[23/4"]23[7/8"] 18.2[3/4"] 27.1 [1 1/8"] 133 [5 1/4"] 17.3 [5/8"] 63.5 [2 1/2"] Transom Window Sash Glazing Bead Window Frame Window Wall Receptor Glazing Bead Aluminum Sill 42[15/8"] 172.4 [6 3/4"] 281.4 [11 1/8"] T.O.S. 7TH FL 62' - 1" E Glazing Bead 81.8 [3 1/4"] to Grid Line E Aluminum Sheet 2mm Aluminum Angle 20x20x2 mm Interior Floor Finishes by others Aluminum Fin Window Wall Frame 30 [1 1/8"] 135 [5 3/8"] 25[1"] Drainage through baffle 53.9 [2 1/8"] 36.5 [1 3/8"] 62 [2 1/2"] 152.4 [6"] 147[53/4"] 58.9 [2 3/8"] 36.6 [1 1/2"] 56.9 [2 1/4"] 215 [8 1/2"] 26.4 [1"] Line of Slab Covers Line of Vertical Fins Aluminum Angle 50X50 Aluminum Angle 50X50 Mineral Wool Insulation Concrete Anchors M10X95 Spacing TBD Waterproofing Membrane 34.7[13/8"] Drainage hole: 6x25mm @ 2' o.c. Project IDDATE 59380 DRAWING NUMBER DRAWING TITLE DRAWN by Skyline Facades VERSION VERSION DATE DESCRIPTION CHECKED by ETEM 00 250 5th Ave Hotel - New York PROJECT TITLE OWNER CONTRACTOR ARCHITECT PROVIDER SERVICES KEY PLAN SUBCONTRACTOR Ε Μ P I R E M A N A G E M E N T The RINALDI G R O U PGENERAL FACADE SYSTEM ENGINEERING FACADE SCALE 1/2'' = 1'' @ ARCH C (24'' x18'') 28 Street 5thAvenue DT - 110 Type K - Section Detail 29 Apr 2018 Issued For Approval REFERENCE DRAWINGS TpK - GA01 SPECIFICATIONS NOTES GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Glass GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Glass GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GLASS TYPES: -Glazing Specifications as per Section 08 00 00 -Curtain Wall Specifications as per Section 08 44 13 Thermally Broken Aluminum Curtain Wall System, Powder Coating Finish -Aluminum Doors Specifications as per Section 08 41 13 Thermally Broken Aluminum Opening Doors System, Powder Coating Finish Etem Doors System E75 Etem Curtain Wall System E85 -Steel Framing, Parapet and Slab Edges Defined according to Structural Drawings -Primary units in mm Etem Window Wall System E86 01 21 Sept 2018 01 Issued For Approval21 Sept 2018
  • 5. 1396.6[4'-631/32"]836.4[2'-815/16"]3326[10'-1015/16"] 2718.2 [8'-11 1/32"]2693.2 [8'-10 1/32"] 494[1'-77/16"] 2359[7'-87/8"] 791.5 [2'-7 5/32"] 206 [8 1/8"] 252.1 [9 15/16"] 170 [6 11/16"] 206[81/8"]210 [89/32"] 3326[10'-1015/16"] 785[2'-629/32"]785[2'-629/32"]785[2'-629/32"] 00 Issued For Approval OWNER CONTRACTOR ARCHITECT PROVIDER SERVICES REFERENCE DRAWINGS KEY PLAN SPECIFICATIONS NOTES SUBCONTRACTOR Ε Μ P I R E M A N A G E M E N T The RINALDI G R O U PGENERAL FACADE SYSTEM ENGINEERING FACADE 28 Street 5thAvenue A-102.02/A-200.01/A-301.01/A-303.01 A-506.01/A-630.01/A-635.00 GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Glass GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Glass GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GLASS TYPES: -Glazing Specifications as per Section 08 00 00 -Curtain Wall Specifications as per Section 08 44 13 Thermally Broken Aluminum Curtain Wall System, Powder Coating Finish -Aluminum Doors Specifications as per Section 08 41 13 Thermally Broken Aluminum Opening Doors System, Powder Coating Finish Etem Doors System E75 Etem Curtain Wall System E85 -Steel Framing, Parapet and Slab Edges Defined according to Structural Drawings -Primary units in mm 08 Aug 2018 F 11[1/2"] 19[3/4"]6[1/4"]5[1/8"] 2[1/8"] 11[1/2"] 19[3/4"]6[1/4"]5[1/8"] 2[1/8"] 91[35/8"] 82[31/4"]toGridLineF 50 [2"] 91[35/8"] 50 [2"] 6 [1/4"] 8 [3/8"] 72 [2 7/8"]5 [1/4"]50 [2"]21 [7/8"] 75[3"] 52 [2"]93 [3 5/8"] Door FrameDoor SashGlazing Bead Glazing Glazing 301[11 7 8''] to Grid Line 3 Pressure Plate and Mullion Cap 110[43/8"] Mullion 15[5/8"] Transom Projection 1830 [6'] Clear Opening Project IDDATE 59380 DT - 308 DRAWING NUMBER ST03-Plan Detail DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 Issued For Approval 250 5th Ave Hotel - New York PROJECT TITLE ARCHITECT PROVIDER SERVICES REFERENCE DRAWINGS KEY PLAN SUBCONTRACTOR FACADE SYSTEM ENGINEERING FACADE SCALE 1/1'' = 1'' @ ARCH C (24'' x18'') 28 Street 5thAvenue GA - 304 08 Aug 2018 08 Aug 2018 SPECIFICATIONS NOTES GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Glass GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Glass GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GLASS TYPES: -Glazing Specifications as per Section 08 00 00 -Curtain Wall Specifications as per Section 08 44 13 Thermally Broken Aluminum Curtain Wall System, Powder Coating Finish -Aluminum Doors Specifications as per Section 08 41 13 Thermally Broken Aluminum Opening Doors System, Powder Coating Finish Etem Doors System E75 Etem Curtain Wall System E85 -Steel Framing, Parapet and Slab Edges Defined according to Structural Drawings -Primary units in mm 3 F 11[1/2"] 19[3/4"]6[1/4"]5[1/8"] 2[1/8"] 50 [2"] 15[5/8"] 50 [2"] 25 [1"] 110[43/8"] 114[41/2"] 82[31/4"]toGridLineF Mullion Gasket Transom Projection 1 [0"] Mineral Wool Insulation 21 [7/8"] Rubber Joint Pressure Plate and Mullion Cap Glazing 60[23/8"]40[15/8"] 20x40x2mm Aluminum L Shaped 40x20x2 mm Aluminum Tube 60x20x2 mm Aluminum Tube Interior Finishes by Others Steel Studs by Others 2693.2 [8'-10''] Frame Opening 26 [1"] to Grid Line 3 PVC Spacen 12 [1/2"] 130 [5 1/8"] 50[2"] 50[2"] 90 [3 1/2"] 95 [3 3/4"] 5 [1/4"] 2 [1/8"] 12 [1/2"] Mullion Baker Rod & Sealant GlazingTransom Projection 441.4[1'-53 8'']toGridLineF Pressure Plate and Mullion Cap 3381.2 [11' - 1 1 8''] to Grid Line 3 Aluminum Spigot (part of bottom curtain wall bracket) 10mm Aluminum Plate Bracket Below 10[3/8"] Baker Rod & SealantPVC Spacen 3367.1[11'-09 16'']RoughOpening PVC Spacen Project IDDATE 59380 DT - 310 DRAWING NUMBER ST03-Plan Detail DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 Issued For Approval 250 5th Ave Hotel - New York PROJECT TITLE OWNER CONTRACTOR ARCHITECT PROVIDER SERVICES KEY PLAN SUBCONTRACTOR Ε Μ P I R E M A N A G E M E N T The RINALDI G R O U PGENERAL FACADE SYSTEM ENGINEERING FACADE SCALE 1/1'' = 1'' @ ARCH C (24'' x18'') 28 Street 5thAvenue GA-304 REFERENCE DRAWINGS SPECIFICATIONS NOTES GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Glass GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60 +3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Glass GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60 Ceramic Coated +3/4" Argon Air Space +3/16"-0.06PVB-3/16" Clear Laminated Tempered Glass GLASS TYPES: -Glazing Specifications as per Section 08 00 00 -Curtain Wall Specifications as per Section 08 44 13 Thermally Broken Aluminum Curtain Wall System, Powder Coating Finish -Aluminum Doors Specifications as per Section 08 41 13 Thermally Broken Aluminum Opening Doors System, Powder Coating Finish Etem Doors System E75 Etem Curtain Wall System E85 -Steel Framing, Parapet and Slab Edges Defined according to Structural Drawings -Primary units in mm 08 Aug 2018 08 Aug 2018
  • 6. 22018 – present Assignment of: -Shop Drawings -Fabrication Drawings -Installation Drawings Scope of work: -Aluminum Curtain Walls -Aluminum Doors & Windows -Aluminum Slab Covers -Aluminum Fins 68 - 70 SPRING STREET New York, USA
  • 7. 2392.9[7'-101/4"]2382.1[7'-93/4"]1255.7[4'-13/8"] FO6030.6[19'-93/8"] 55.8[21/4"] (Sill) 574.7 [1'-10 5/8"]574.7 [1'-10 5/8"] 558.8[1'-10"] D E 1291.4 [4'-2 7/8"] 5832.5 [19'-1 5/8"] 609.6[2'] T.O.F. 3rd FL 28' - 00" 6096[20'](8''tilesx30)609.6[2']609.6[2'] D.1 609.6[2'] 609.6[2'] 30' - 00" 50' - 00" RO6151.6[20'-21/8"] ROfromSteelStudtoSteelStud UnitsA,B L.O. SteelStud 50' - 02" FO 2328.1 [7'-7 5/8"] TO 2346.3 [7'-8 3/8"] R.O.=2352.6 [7'-8 5/8"] FO 1158.9 [3'-9 5/8"] TO 1177.9 [3'-10 3/8"] RO 1184.2 [3'-10 5/8"] From Steel Stud to Steel Stud FO 1158.9 [3'-9 5/8"] TO 1177.9 [3'-10 3/8"] RO 1184.2 [3'-10 5/8"] From Steel Stud to Steel Stud 2432.1[7'-113/4"]1155.7[3'-91/2"]2498.7[8'-23/8"]614.4[2'-01/8"] 50[2"]1775.6[5'-97/8"]50[2"]506.5[1'-8"]50[2"]1155.7[3'-91/2"]50[2"]1786.3[5'-103/8"]50[2"]506.5[1'-8"] 50[2"] 55.8[21/4"] 208[81/4"] T.O.F. 3rd FL 28' - 00" T.O.F. 4th FL 40' - 00" T.O.F. 5th FL 52' - 00" 406.4[1'-4"] 26.8 [1"] 406.4[1'-4"]614.4[2'-01/8"] 55.8[21/4"] 406.4[1'-4"] 165.1 [6 1/2"] 125.2 [4 7/8"] UNITS A - B ELEVATION UNITS A - B SECTION FO 3481.6 [11'-5 1/8"] RO 3505.2 [11'-6"] T.O.F. 2nd FL 16' - 00" T.O.F. 1st FL 0' - 00" 979.1 [3'-2 1/2"] 200 [7 7/8"] 873.4 [2'-10 3/8"] 200 [7 7/8"] 979.1 [3'-2 1/2"] 2360[7'-87/8"]1294.4[4'-3"]2997.8[9'-10"] DCB 127.8 [5"]127.8 [5"] 1244.5[4'-1"] D.1A.9 FO7896.7[25'-107/8"] RO7916.9[25'-113/4"] Maxtorque (Nm)50 Maxtorque (Nm)50 Maxtorque (Nm)50 7896.7[25'-107/8"] 7916.9[25'-113/4"] 75[3"] 50[2"]1650.7[5'-5"] 50[2"] 534.3[1'-9"] 50[2"] 1194.4[3'-11"] 50[2"] 1194.5[3'-11"] 50[2"]2997.8[9'-10"] 614.4[2'-01/4"] T.O.F. 2nd FL 16' - 00" T.O.F. 1st FL 0' - 00" 1 369.1 [1'-2 1/2"] 290 [11 3/8"] 659.1 [2'-2"] T.O.F. 2nd fl 15' - 10" T.O.S. 1st FL -0' - 02" Maxtorque (Nm)50 Maxtorque (Nm)50 Maxtorque (Nm)50 7896.7[25'-107/8"] 7916.9[25'-113/4"] 75[3"] 50[2"]1650.7[5'-5"] 50[2"] 534.3[1'-9"] 50[2"] 1194.4[3'-11"] 50[2"] 1194.5[3'-11"] 50[2"]2997.8[9'-10"] 614.4[2'-01/4"] 1 369.1 [1'-2 1/2"] 290 [11 3/8"] 659.1 [2'-2"] 2028.4 [6'-7 7/8"] Project IDDATE 23 May 2018 68SPR 106 DRAWING NUMBER North Partial Elevation and Section DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR FACADE SYSTEM ENGINEERING FACADE SCALE 1/16'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Section 106 -2 Scale as notedElevation 106 -1 Scale as noted Section 106 -3 Scale as noted 200 [7 7/8"] 979.1 [3'-2 1/2"] 2360[7'-87/8"]1294.4[4'-3"]2997.8[9'-10"] D 127.8 [5"] 1244.5[4'-1"] D.1 Maxtorque (Nm)50 Maxtorque (Nm)50 Maxtorque (Nm)50 7896.7[25'-107/8"] 7916.9[25'-113/4"] 75[3"] 50[2"]1650.7[5'-5"] 50[2"] 534.3[1'-9"] 50[2"] 1194.4[3'-11"] 50[2"] 1194.5[3'-11"] 50[2"]2997.8[9'-10"] 614.4[2'-01/4"] T.O.F. 2nd FL 16' - 00" T.O.F. 1st FL 0' - 00" 1 369.1 [1'-2 1/2"] 290 [11 3/8"] 659.1 [2'-2"] T.O.F. 2nd fl 15' - 10" T.O.S. 1st FL -0' - 02" Maxtorque (Nm)50 Maxtorque (Nm)50 Maxtorque (Nm)50 7896.7[25'-107/8"] 7916.9[25'-113/4"] 75[3"] 50[2"]1650.7[5'-5"] 50[2"] 534.3[1'-9"] 50[2"] 1194.4[3'-11"] 50[2"] 1194.5[3'-11"] 50[2"]2997.8[9'-10"] 614.4[2'-01/4"] 1 369.1 [1'-2 1/2"] 290 [11 3/8"] 659.1 [2'-2"] 2028.4 [6'-7 7/8"] Project IDDATE 23 May 2018 68SPR 106 DRAWING NUMBER North Partial Elevation and Section DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR FACADE SYSTEM ENGINEERING FACADE SCALE 1/16'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Section 106 -2 Scale as notedElevation 106 -1 Scale as noted Section 106 -3 Scale as noted Maxtorque (Nm)50 Max torque (Nm) 50 50 [2"] Aluminum Mullion Aluminum Angle 40 x 40 x 2 20 [3/4"] 88[31/2"] 50 [2"] 11.8 [1/2"] Pressure Plate Aluminum Cap 120 x 20 x 2 55 [2 1/8"] 14.2 [1/2"] 68.3 [2 3/4"] 20 [3/4"] 93.7[33/4"] 28[11/8"] 128.9[51/8"] Projected Window Sash Terra cotta by Others Interior Finishes By Others Seal on Backer Rod Waterproofing Membrane SF1 F.D. 13'-4 1/8'' 11.8 [1/2"] SF2 F.D. 11'-5 1/8'' SF1 R.O. 13'-5'' SF2 R.O. 11'-6'' Max torque (Nm) 50 Maxtorque (Nm)50 Maxtorque (Nm)50 200 [7 7/8"] 20 [3/4"]50 [2"]20 [3/4"] 55 [2 1/8"]55 [2 1/8"] 88[31/2"] 30[11/8"]88[31/2"] 40.3 [1 5/8"] 68.3 [2 3/4"] 200 [7 7/8"] 77[3"] 87[33/8"]63[21/2"]28[11/8"] 130[51/8"]25.4[1"] Aluminum Mullion Pressure Plate Aluminum Cap 120 x 20 x 2 Projected Window Sash 100 x 20 x 2 Project IDDATE 23 May 2018 68SPR 110 DRAWING NUMBER North Plan Details DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 1'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Detail 110 - 2 Scale as noted Detail 110 - 2 Scale as noted2nd Floor SF1 Ref. Shildan 5.3, 5.2, 5.1 E85104 2 1 50 [2"] 20 [3/4"]8 [3/8"]40.4 [1 5/8"]20 [3/4"] 8 [3/8"] 40.4 [1 5/8"] 56[21/4"]37.8[11/2"] 56[21/4"]37.8[11/2"]77[3"]166.7[61/2"] 25.9[1"]toGridLine1 14.2 [1/2"] 50 [2"] 14.2 [1/2"] 1460.5 [4'-9 1/2"] to Grid Line D1 Aluminum Mullion Aluminum Cap Window Sash Glass Gasket Window Frame Slab Edge (3rd & 5th floor) Slab Edge (4th & 6th floor) Line of Mullions and Transcents Edge 1 77[3"]56[21/4"]37.8[11/2"]166.7[61/2"] 28[11/8"] 50 [2"]12.7 [1/2"] 68.4 [2 3/4"] 25.9[1"]toGridLine1 1456 [4'-9 3/8"] to Grid Line D1 R.O.=1184 [3'-10 5/8"] (Type A,A1,C) F.D.=1159 [3'-9 5/8"] 337.4[1'-11/4"] Aluminum Mullion Aluminum Mullion Window Sash Glass Gasket Window Frame Slab Edge (3rd & 5th floor) Slab Edge (4th & 6th floor) Terracota Cladding by others Interior Walls by others Line of Mullions and Transcents Edge Pressure Plate Cap 9.6 [3/8"] 3' - 9 15/16" Seal on Backer Rod Detail 103 -1 scale as noted Detail 103 -2 scale as noted Project IDDATE 23 May 2018 68SPR 103 DRAWING NUMBER North Plan Detail DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 1'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Ref. Shildan 5.4, 5.5, 5.6 E85104 2 1 50 [2"] 20 [3/4"]8 [3/8"]40.4 [1 5/8"]20 [3/4"] 8 [3/8"] 40.4 [1 5/8"] 56[21/4"]37.8[11/2"] 56[21/4"]37.8[11/2"]77[3"]166.7[61/2"] 25.9[1"]toGridLine1 14.2 [1/2"] 50 [2"] 14.2 [1/2"] 1460.5 [4'-9 1/2"] to Grid Line D1 Aluminum Mullion Aluminum Cap Window Sash Glass Gasket Window Frame Slab Edge (3rd & 5th floor) Slab Edge (4th & 6th floor) Line of Mullions and Transcents Edge 1 77[3"]56[21/4"]37.8[11/2"]166.7[61/2"] 28[11/8"] 50 [2"]12.7 [1/2"] 68.4 [2 3/4"] 25.9[1"]toGridLine1 1456 [4'-9 3/8"] to Grid Line D1 R.O.=1184 [3'-10 5/8"] (Type A,A1,C) F.D.=1159 [3'-9 5/8"] 337.4[1'-11/4"] Aluminum Mullion Aluminum Mullion Window Sash Glass Gasket Window Frame Slab Edge (3rd & 5th floor) Slab Edge (4th & 6th floor) Terracota Cladding by others Interior Walls by others Line of Mullions and Transcents Edge Pressure Plate Cap 9.6 [3/8"] 3' - 9 15/16" Seal on Backer Rod Detail 103 -1 scale as noted Detail 103 -2 scale as noted Project IDDATE 23 May 2018 68SPR 103 DRAWING NUMBER North Plan Detail DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 1'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Ref. Shildan 5.4, 5.5, 5.6 Aluminum Mullion Window Sash Window Frame Aluminum Cap Glass Slab Edge of 4th & 6th fl. Slab Edge of 3th & 5th fl. 50 [2"] 20.4 [3/4"] 53 [2 1/8"]20.4 [3/4"]73.4 [2 7/8"] 95.5[33/4"]166[61/2"]75.5[3"] 31.5[11/4"] 67.5[25/8"] 188.8 [7 3/8"] 50 [2"]69.4 [2 3/4"] 69.4 [2 3/4"] 95.5[33/4"]166[61/2"] 35.5[13/8"]8[3/8"] 50 [2"] 20.4 [3/4"] 53 [2 1/8"] 50 [2"] 69.4 [2 3/4"] 25.9[1"]toGridLine1 1 75.5[3"] 32[11/4"] R.O.=1184 [3'-10 5/8"] (Type A,A1,C) F.D.=1159 [3'-9 5/8"] 1456 [4'-9 3/8"] to Grid Line D1 Aluminum Mullion Window Sash Window Frame Aluminum Mullion Glass Slab Edge of 4th & 6th fl. Slab Edge of 3th & 5th fl. 12.7 [1/2"] Pressure Plate Cap Concealed sash window frame Interior Finishes By Others Terra cotta by Others 9.6 [3/8"] 3' - 9 15/16" Seal on Backer Rod Detail 102 - 1 scale as noted 32[11/4"] Detail 102 - 2 scale as noted Project IDDATE 23 May 2018 68SPR 102 DRAWING NUMBER North Plan Detail DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 1'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Ref. Shildan 5.4, 5.5, 5.6 556.5[1'-97/8"] 50[2"] 14.3[1/2"] 68.4[23/4"] Custom Wind Load bearing Bracket 55.8[21/4"] 60.3[23/8"] 101.6 [4"] 346.1[1'-15/8"] 165.1 [6 1/2"] 123.2 [4 7/8"] 63.4 [2 1/2"] Mineral Wool 50 x 50 x 3 Aluminum cap Aluminum transom 1 63.4 [2 1/2"] M10 Bolt Set 406.4[1'-4"] T.O. SteelStud 30' - 00" 110.6[43/8"] Waterproof Membrane 660.4[2'-02''] toSlab TERRACOTAFACEPROJECTION Maxtorque (Nm)50 Maxtorque (Nm)50 T.O.F. 4th FL 40' - 00" M12 x 140 concrete anchor 120[43/4"] Custom Dead Load bearing Bracket 53[21/8"] 73.4[27/8"] 75.5 [3"] 69.4[23/4"]50[2"] 140 [5 1/2"]26 [1"] 1 4th Fl. T.O.S. 4th FL 39' - 10" 368.3 [1'-2 1/2"] 312 [1'-0 1/4"] 38' - 08" 138.2[51/2"] TERRACOTAFACEPROJECTION 556.5[1'-97/8"] 73.4[27/8"] 68.4[23/4"] 50[2"]69.4[23/4"]14.3[1/2"] 9[3/8"] 127 [5"]26 [1"] Projected window sash Concealed sash window 1 RO6146.8[20'-02''] ROfromSteelStudtoSteelStud UnitsA,B Detail 105 -1 Scale as noted Detail 105 -2 Scale as noted Detail 105 -2 Scale as noted Project IDDATE 23 May 2018 68SP 105 DRAWING NUMBER North Section Details DRAWING TITLE DRAWN by Skyline Facades VERSIO 00 VERSION DATE DESCRIPTION CHECKED by ETE 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 2'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Sill Detail A-B Ref. Shildan 5.15 556.5[1'-97/8"] 50[2"] 14.3[1/2"] 68.4[23/4"] Custom Wind Load bearing Bracket 55.8[21/4"] 60.3[23/8"] 101.6 [4"] 346.1[1'-15/8"] 165.1 [6 1/2"] 123.2 [4 7/8"] 63.4 [2 1/2"] Mineral Wool 50 x 50 x 3 Aluminum cap Aluminum transom 1 63.4 [2 1/2"] M10 Bolt Set 406.4[1'-4"] T.O. SteelStud 30' - 00" 110.6[43/8"] Waterproof Membrane 660.4[2'-02''] toSlab TERRACOTAFACEPROJECTION Maxtorque (Nm)50 Maxtorque (Nm)50 T.O.F. 4th FL 40' - 00" M12 x 140 concrete anchor 120[43/4"] Custom Dead Load bearing Bracket 53[21/8"] 73.4[27/8"] 75.5 [3"] 69.4[23/4"]50[2"] 140 [5 1/2"]26 [1"] 1 4th Fl. T.O.S. 4th FL 39' - 10" 368.3 [1'-2 1/2"] 312 [1'-0 1/4"] 38' - 08" 138.2[51/2"] TERRACOTAFACEPROJECTION 556.5[1'-97/8"] 73.4[27/8"] 68.4[23/4"] 50[2"]69.4[23/4"]14.3[1/2"] 9[3/8"] 127 [5"]26 [1"] Projected window sash Concealed sash window 1 RO6146.8[20'-02''] ROfromSteelStudtoSteelStud UnitsA,B Detail 105 -1 Scale as noted Detail 105 -2 Scale as noted Detail 105 -2 Scale as noted Project IDDATE 23 May 2018 68SP 105 DRAWING NUMBER North Section Details DRAWING TITLE DRAWN by Skyline Facades VERSI 00 VERSION DATE DESCRIPTION CHECKED by ETE 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 2'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Sill Detail A-B Ref. Shildan 5.15 50[2"] 26 [1"] 166 [6 1/2"] 241.5 [9 1/2"] 32 [1 1/4"] 96.5 [3 3/4"] 9.6[3/8"] 69.4[23/4"] 73.4[27/8"] 1 Custom Wind Load bearing Bracket M10 Bolt Set transom Window frame Concealed sash window Aluminum cap Pressure plate 5th Fl. L.O. SteelStud 50' - 02" 50' - 08" Structural Framing by GC for windows attachments and TC (TYP) Structural Framing by GC for windows attachments and TC (TYP) 50' - 00" 55.6[21/4"] RO6146.8[20'-02''] ROfromSteelStudtoSteelStud UnitsA,B 312 [1'-0 1/4"] 203.2 [8"] TERRACOTAFACEPROJECTION Detail 104 -1 Scale as noted Head Detail A-B Ref. Shildan 5.14 Maxtorque (Nm)50 Max torque (Nm) 50 50 [2"] Aluminum Mullion Aluminum Angle 40 x 40 x 2 20 [3/4"] 88[31/2"] 50 [2"] 11.8 [1/2"] Pressure Plate Aluminum Cap 120 x 20 x 2 55 [2 1/8"] 14.2 [1/2"] 68.3 [2 3/4"] 20 [3/4"] 93.7[33/4"] 28[11/8"] 128.9[51/8"] Projected Window Sash Terra cotta by Others Interior Finishes By Others Seal on Backer Rod Waterproofing Membrane SF1 F.D. 13'-4 1/8'' 11.8 [1/2"] SF2 F.D. 11'-5 1/8'' SF1 R.O. 13'-5'' SF2 R.O. 11'-6'' Max torque (Nm) 50 Maxtorque (Nm)50 Maxtorque (Nm)50 200 [7 7/8"] 20 [3/4"]50 [2"]20 [3/4"] 55 [2 1/8"]55 [2 1/8"] 88[31/2"] 30[11/8"]88[31/2"] 40.3 [1 5/8"] 68.3 [2 3/4"] 200 [7 7/8"] 77[3"] 87[33/8"]63[21/2"]28[11/8"] 130[51/8"]25.4[1"] Aluminum Mullion Pressure Plate Aluminum Cap 120 x 20 x 2 Projected Window Sash 100 x 20 x 2 Project IDDATE 23 May 2018 68SPR 110 DRAWING NUMBER North Plan Details DRAWING TITLE DRAWN by Skyline Facades VERSION 00 VERSION DATE DESCRIPTION CHECKED by ETEM 00 23 May 2018 Issued For Approval 68 - 70 Spring Street PROJECT TITLE DEVELOPER ARCHITECT PROVIDER SERVICES SUBCONTRACTOR DJL Limited Development FACADE SYSTEM ENGINEERING FACADE SCALE 1'' = 1'' @ ARCH D (36'' x 24'') BIALOSKY New York Detail 110 - 2 Scale as noted Detail 110 - 2 Scale as noted2nd Floor SF1 Ref. Shildan 5.3, 5.2, 5.1
  • 8. 32012-2013 Assignment of: -New Aluminum Cladding System development (W-1016) -Tender Stage Estimation -Shop Drawings -Bill of Materials -Fabrication Drawings -Installation Drawings Scope of work: -Aluminum Composite Panels Cladding -Decorative Aluminum Screen Walls -Suspended Metal Ceilings TORONTO PREMIUM OUTLET Toronto, Canada
  • 9. M10 connection Parts ----> 5mm thick -------> PR M10 connection parts M10 safety nuts L angle L-10(47-90mm) Lower part of gallery joist (by others) M10 Channel nuts CSN4141 washer M10 Channel nuts CN4141 L-18B (5mm thick) Upper part of gallery joist (by others) L-02 (5mm thick) L-01 (5mm thick) M10 connection parts long Lower part of gallery joist (by others) Upper part of gallery joist (by others) PR Pair rods for indirect suspension of basic part P4141 detail 6 804.67 64 detail 6b PR (P4141E) Pair rods Under Gallery parts Length (mm)Code Qnty (pcs) -L-10 64 M10 connection Parts ----> 5mm thick -------> PR M10 connection parts M10 safety nuts L angle L-10(47-90mm) Lower part of gallery joist (by others) M10 Channel nuts CSN4141 washer M10 Channel nuts CN4141 L-18B (5mm thick) Upper part of gallery joist (by others) L-02 (5mm thick) L-01 (5mm thick) M10 connection parts long Lower part of gallery joist (by others) Upper part of gallery joist (by others) PR Pair rods for indirect suspension of basic part P4141 system used: PROJECT: ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS NOTES: detail 6 804.67 64 Scale: Project No: 1203 Td 1 : 8 Revision A: Design Date: Revision B: 02 MAY 2013 Detail ID: Part No: Susp_partUGal Pair rods under gallery joist detail 6b All dimensions added by Elegant Facade are in mm. PR (P4141E) Pair rods Under Gallery parts Length (mm)Code Qnty (pcs) -L-10 64 -M10 channel nuts CSN4141 M10 channel nuts CN4141 - 64 M10 connection part 64 M10 safety nuts 256 512 Washer 448 L-18 64 Plate L-01 64 Plate L-02 64 M10 connection part(long) 128 - - - - - - - Detail 5b Detail 5a Detail 5a M10 Channel nuts CSN4141 Angle L-09B M10 connection parts substructure rod P4141x2(41x82mm) suspension rod P4141(41x41mm) substructure rod P4141x2(41x82mm) suspension rod P4141(41x41mm) M10 Channel nuts CSN4141 M10 safety nuts Washer M10 Channel nuts CN4141 M10 connection parts Angle L-09B Angle L-18B Details 5a - 5b Exploded Detail 5a system used: PROJECT: ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS NOTES: Project No:1203 Td Revision A: Design Date: Revision B: 02 MAY 2013 Detail ID: Part No:SubSusp_Det-5 Substructure between Scale: 1 : 25 parts -suspension detail suspension rod P4141(41x41mm) substructure rod P4141x2(41x82mm) Angle L-09B M10 connection part M10 Channel nuts CSN4141 M10 Channel nuts CN4141 M10 safety nuts washer M10 Channel nuts CN4141 Angle L-13E Perforated panel Exploded Detail 1 system used: PROJECT: ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS NOTES: Scale: Project No:1203 Td 1 : 25 Revision A: Revision B: Detail ID: Part No:Sub_Det-1 RCP substructure detail (corner)All dimensions added by Elegant Facade are in mm. substructure rod P4141x2(41x82mm) suspension rod P4141(41x41mm) Angle L-13E M10 Channel nuts CSN4141 Angle L-09B Exploded Detail 1b system used: PROJECT: ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS NOTES: Scale: Project No:1203 Td 1 : 25 Revision A: Design Date: Revision B: 02 MAY 2013 Detail ID: Part No:Sub_Det-1b RCP substructure detail(corner)All dimensions added by Elegant Facade are in mm. M10 Channel nuts CSN4141 M10 Channel nuts CN4141 M10 Channel nuts CSN4141 M10 safety nuts suspension rod P4141(41x41mm) L-09B substructure rod P4141x2(41x82mm) substructure rod P4141x2(41x82mm) Angle L-18B Angle L-09B Angle L-18B Plate L-02A system used: PROJECT: ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS NOTES: Scale: Project No: 1203 Td 1 : 18 , 1:14 Revision A: Design Date: Revision B: 02 MAY 2013 Detail ID: Part No: Sr_A-B-C-D Suspension rods parts details All dimensions added by Elegant Facade are in mm. 2040 9Sr-A(P4141 41x41mm) part A Suspension rods & componets Length (mm)Code Qnty (pcs) 2588 1735 12Sr-B(P4141 41x41mm) part B Sr-D(P4141 41x41mm) part D 92040 3588 Sr-C (P4141 41x41mm) part C 1278 27 662.7 3 L-09B(partA) 66 M10 channel nuts CSN4141 130 M10 safety nuts Washer 132 M10 connection parts M10 channel nuts CN4141 66 68 - - - - - - - - 132 L-02A 2- Weather Barrier Tyvec HomeWrap Seathing PreDrilled E-16150 ST 4,2 (No 10) Length 30mm Fix PreDrilled E-16150 perimetrically at the under edge of the canopy, usind No 10 Selfdrilling screws PreDrilled E-16900 Fix PreDrilled E-16900 at the middle, usind No 10 Selfdrilling screws Canopy Edge INDICATIVE APPLY Elegant Façade Inc. Architectural Solutions Alumicore WS 1016 1203 GD-10 Generic Drawings For PROJECT 1203 (TPO) Alumicore ACP Slide the ACP panel into the grooves. Canopy Edge INDICATIVE APPLY Elegant Façade Inc. Architectural Solutions Alumicore WS 1016 1203 GD-16 Generic Drawings For PROJECT 1203 (TPO) BETWEEN TWO TYPICAL BRACKETS (EVERY 5ft) WE PLACE 5 PLATE HOLDERS (EVERY 1ft) STARTING 1/2 ft FROM THE EDGE. 1ft 1ft 1ft 1ft 1 2 ft 1 2 ft 1ft 1 2 ft 5ft 1 2 ft 6 6.1 6.2 1213.4 [3'-11 3/4"] 1213.4 [3'-11 3/4"] 1214.2 [3'-11 3/4"] 1212.9 [3'-11 3/4"] 63.1 [2 1/2"] to Grid Line 6.1 3048.8 [10'] 914.6 [3'] 101.6 [4"] 101.6 [4"] 914.6 [3'] 2082.3[6'-10"] 1778[5'-10"] 2082.3[6'-10"] 1778[5'-10"] 456.8[1'-6"] 50[2"] 100' - 0'' T/O FIN. FLOOR 117' - 6'' T/O FRAMING 5333.7[17'-6"] S.3 S.1 1213.4 [3'-11 3/4"] 1213.4 [3'-11 3/4"] 1214.2 [3'-11 3/4"] 1212.9 [3'-11 3/4"] 63.1 [2 1/2"] to Grid Line 6.1 2205.2 [7'-2 7/8"] to Grid Line 6.2 743[2'-51/4"] toGridLineS.1 304.8[1'] 6 6.1 6.2 03 GA-02 sim PD-06 S.1 124' - 0'' T/O STEEL BEAM 203.2[8"] S.3 117' - 6'' T/O FRAMING 110' - 9'' U/S STEEL 100' - 0'' T/O FIN. FLOOR 203.2[8"]583.9[1'-11"] 304.8 [1'] sim SD-19 508[1'-8"]506.9[1'-8"]509.9[1'-81/8"]508[1'-8"]279[11"] 2082.6[6'-10"] 743 [2'-5 1/4"] to Grid Line S.1 3251.4[10'-8"] 02. Floorplan 1/30 03. Section 1/16 01. ELevation 1/30 DATE DRAWING NUMBER DRAWING TITLE VERSION VERSION DATE DESCRIPTION 00 11 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 B12-GA02 Partial South Elevation - Section DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) as Noted @ ARCH D (36'' x24'') REFERENCE DRAWINGS KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple A12-01, A12-01A, A12-03, A12-04, A12-09 NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410 or 300 series if exposed. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy=110MPa). -LePage construction adhesive to be applied and cured as per manufacturers instructions. -Dimensions to be verified on site 20 Jul 2018 01 01 20 Jul 2018 Issued For Approval
  • 10. 42018 Assignment of: -New Aluminum Cladding System development (W-1415) -Tender Stage Estimation -Shop Drawings -Bill of Materials -Fabrication Drawings -Installation Drawings Scope of Work: -Aluminum Composite Panels Cladding -Brick Cladding -Fiber Cement Board Cladding -Decorative Aluminum Screen Walls TORONTO PREMIUM OUTLET_ EXPANSION Toronto, Canada
  • 11. U.1T.9T.5 124' - 4'' T/O PARAPET 122' - 4'' T/O PARAPET 137' - 0'' T/O PARAPET T 1158.3 [3'-9 5/8"]1219.2 [4']1219.2 [4']1219.2 [4']605.5 [1'-11 7/8"] 709.8[2'-4"] 6637.9[21'-93/8"] S.10 1219.2 [4'] 1219.2 [4'] 1219.2 [4'] 1219.2 [4'] 303.4[1'] 4876.8 [16'] 02 GA-07 431.4[1'-5"] 864.4[2'-10"] 253.2[10"] 864.4[2'-10"] 2438.4[8'] 764 [2'-6 1/8"] 384.3 [1'-3 1/8"] 1201.9 [3'-11 3/8"] 108.4[41/4"] 303.4[1'] 80.3[31/8"] 520.2[1'-81/2"] 456.7[1'-6"] 4217 [13'-10"] 5283.2 [17'-4"] 92.6[35/8"] 103[4"] 10.6[3/8"] 1224.6 [4']1224.6 [4'] 690.6 [2'-3"]690.6 [2'-3"] 1224.6 [4']1224.6 [4'] 690.6 [2'-3"]690.6 [2'-3"] 1040.9[3'-5"] 100' - 0'' F.FL. 1322.2[4'-4"] MP2 MP2MP2MP2 MP2MP2 MP1MP1 CL1 CL1CL1 MP2MP2 B1 B1 S1 S1 02 GA-07 01 GA-07 11.10 11.8 T.9T.5 S.10 T U.1 307.8[1'-01/8"] 709.8 [2'-4"] 336.1 [1'-1 1/4"] 1219.2[4']413.5[1'-41/4"] 788.4 [2'-7"] 413.5 [1'-4 1/4"] 1201.9 [3'-11 3/8"] 357.6[1'-21/8"] toGridLine11.10 535.1 [1'-9 1/8"] to Grid Line U.1 666.8 [2'-2 1/4"] to Grid Line U.1 509.4[1'-8"] sim PD-02 761.3 [2'-6"] to Grid Line S.10 609.6 [2'] to Grid Line T 422.3[1'-45/8"] toGridLine11.8 1330.3 [4'-4 3/8"] 720.7 [2'-4 3/8"] to Grid Line T 3159.1 [10'-4 3/8"] to Grid Line T 1338.4 [4'-4 3/4"] 4497.5 [14'-9 1/8"] to Grid Line T 934.7 [3'-0 3/4"] 933 [3 '-0 3/4 "] 138.6[51/2"] toGridLine11.10 sim PD-07 sim PD-07 sim PD-07 175.6[67/8"] DATE DRAWING NUMBER DRAWING TITLE VERSION VERSION DATE DESCRIPTION 00 11 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 B12-GA06 Partial East Elevation DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) 1/30 @ ARCH D (36'' x24'') REFERENCE DRAWINGS A12-01, A12-01B, A12-03, A12-05, A12-06, A12-10 KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple 02. Floor plan 1/30 20 Jul 2018 01 01 20 Jul 2018 Issued For Approval NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches o thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410 or 300 series if exposed. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy=110MPa). -LePage construction adhesive to be applied and cured as per manufacturers instructions. -Dimensions to be verified on site Q.12 Q.10 125' - 8'' T/O PARAPET 2438.4[8'] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1219.3 [4'] 1219.3 [4'] 1219.3 [4'] 1219.3 [4'] 1303.7 [4'-3 3/8"]1219.3 [4']1219.3 [4']1219.3 [4']1305.7 [4'-3 3/8"] 03 GA-06 03 GA-06 03 GA-07 819[2'-81/4"]964.2[3'-2"]963.5[3'-2"]963.5[3'-2"]963.5[3'-2"]951.9[3'-11/2"] 1219.3 [4'] 9250.7 [30'-4 1/4"] 101.6[4"] 2183.7[7'-2"] 101.6[4"] 2183.7[7'-2"] 03 GA-07 MP2 MP2MP2 MP4 1219.3 [4']1219.3 [4']1219.3 [4']1219.3 [4']1219.3 [4']967.6 [3'-2 1/8"] 967.7 [3'-2 1/8"] 1727.2[5'-8"]914.7[3'] MP2 1727.2[5'-8"]914.7[3'] MP2 7250 [23'-9 3/8"] 4Q 5Q 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 305.6[1'] 50[2"] 03 GA-07 03 GA-07 03 GA-06 03 GA-06 251.4[97/8"] 204.7[8"] 776.1 [2'-6 1/2"] 251.6 [9 7/8"] 697.5 [2 '-3 1/2"] 204.7 [8 "] 204.7 [8 "] 254.4 [1 0"] 697.5 [2 '-3 1/2"] 776.1 [2'-6 1/2"] 251.4[97/8"] 204.7[8"] 125' - 8'' T/O PARAPET 4Q 125' - 6'' T/O STEEL 117' - 6'' U/S DECK 112' - 0'' U/S OF CANOPY 109' - 0'' T/O GLAZING 110' - 3/8'' U/S STEEL 100' - 0'' T/O FIN. FLOOR 5Q 571.7[1'-101/2"]571.7[1'-101/2"]574.7[1'-105/8"]568.7[1'-103/8"] 358.6 [1'-2 1/8"] 355.6 [1'-2"] 305.6 [1'] 2438.4[8']4329.4[14'-21/2"] 6717[22'-01/2"] MP2 DATE 08 Jun 2018 DRAWING NUMBER DRAWING TITLE VERSION 01 VERSION DATE DESCRIPTION 08 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 B10-GA7 North West Elevation & Plan-Section DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) as noted @ ARCH D (36'' x24'') REFERENCE DRAWINGS KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). 10 00 03. Section 1/1602. Plan 1/30 A10-01, A10-01A, A10-03, A10-04, A10-08 18 Jun 2018 Issued For Approval01 125' - 8'' T/O PARAPET 4Q 125' - 6'' T/O STEEL 117' - 6'' U/S DECK 112' - 0'' U/S OF CANOPY 109' - 0'' T/O GLAZING 110' - 3/8'' U/S STEEL 100' - 0'' T/O FIN. FLOOR 5Q 571.7[1'-101/2"]571.7[1'-101/2"]574.7[1'-105/8"]568.7[1'-103/8"] 358.6 [1'-2 1/8"] 355.6 [1'-2"] 305.6 [1'] 2438.4[8']4329.4[14'-21/2"] 6717[22'-01/2"] MP2 DATE 08 Jun 2018 DRAWING NUMBER DRAWING TITLE VERSION 01 VERSION DATE DESCRIPTION 08 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 B10-GA7 North West Elevation & Plan-Section DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) as noted @ ARCH D (36'' x24'') REFERENCE DRAWINGS KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). 10 00 03. Section 1/16 A10-01, A10-01A, A10-03, A10-04, A10-08 18 Jun 2018 Issued For Approval01 1219.2 [4']1219.6 [4'] 1219.2 [4'] 1102 [3'-7 3/8"]726.4 [2'-4 5/8"] 417.6 [1'-4 1/2"] 31.133.134 132' - 0'' T/O PARAPET 01 GA-10 4368.8[14'-4"] 5486.4 [18'] 6014.7 [19'-8 3/4"] 1324[4'-41/8"] 101.6[4"] 282.4 [11 1/8"]3226.3 [10'-7"] 1330.2[4'-43/8"] 1219.2 [4']1219.6 [4'] 1219.2 [4'] 1102 [3'-7 3/8"]726.4 [2'-4 5/8"] 990.6 [3'-3"] 1219.2 [4'] 1219.2 [4'] 1219.2 [4'] 1366.5 [4'-5 3/4"] 31 1320.8[4'-4"] 1207 [3'-11 1/2"] 1219.2 [4']1219.2 [4']721.8 [2'-4 3/8"] 1219.6 [4']1219.6 [4']1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4']871.3 [2'-10 1/4"] 871.3 [2'-10 1/4"] 5080 [16'-8"] TT.9 TT.8 TT.7 3707.6 [12'-2"] 305.5[1'] 50[2"] 1205.5 [3'-11 1/2"] 262.8[103/8"] DATE DRAWING NUMBER DRAWING TITLE VERSION 00 VERSION DATE DESCRIPTION Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 B14-GA08 Partial North Elevation & Plan DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) 1/30 @ ARCH D (36'' x24'') REFERENCE DRAWINGS KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). 10 00 05 Jul 2018 05 Jul 2018 A14-01A, A14-03, A14-04, A14-09, A14-10 14 01. ELevation 1/30 02. Floorplan 1/30 M10threadedRod 110 [4 3/8"] 150[57/8"] 80[31/8"] 50 [2"] 255.6 [10 1/8"] 50 [2"] 50.8 [2"] 9.8 [3/8"] 18.6 [3/4"] 152.4 [6"] 15.9 [5/8"] 3 [1/8"] 50.8 [2"] 50[2"]424.7[1'-43/4"]50[2"] 101.6[4"]50.8[2"]101.6[4"]50.8[2"]101.6[4"]50.8[2"]101.6[4"]25[1"]25[1"] 50 [2"] 50[2"] 3[1/8"] 42[15/8"] 42 [1 5/8"] 3 [1/8"] 50 [2 "] 70.7[23/4"] 35[13/8"] 100 [3 7/8"] 258.5[101/8"] 36 1 [1 '-2 1/ 4" ] 45° 42 [1 5/8"] ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C ST6.3(No14) DIN7982-C ST6.3(No14) DIN7982-C ST6.3(No14) DIN7982-C 2 Screws per Slat M10 Bolt Set 35 x3mm (1 3 8'' x 1 8'') Aluminum plate pre-connected to slats Wood blocks from steel stud to steel stud designed, supplied and installed by others Blocking and steel studs to able to support the following factored loads: Vert.= 0.7 kN (downwards) Hor.= 1.7 kN (inward or outward) U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C Aluminum angle 50x50x3 U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C 3mm aluminum plate both sides Aluminum slat 2''x4''x1/8'' Nut & 25mm Dia Washer 50x110x3 SS Angles min 38 mm 18 [3/4"] DATE 16 MAY 2018 DRAWING NUMBER DRAWING TITLE VERSION 01 VERSION DATE DESCRIPTION 00 06 Apr 2018 Issued For Approval PROJECT TITLE SCALE 1/2'' = 1'' @ ARCH C (24'' x18'') SD-08 Section Detail (MP5 Screen) DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) Project ID 15124.03 REFERENCE DRAWINGS 01/B9-GA9 KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS NOTES - Primary Units are in mm - All Cladding surfaces had been coordinated to be 2'' outer of the provided sheathing METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). 01 16 May 2018 Issued For Approval 50[2"] 3 [1/8"] 50 [2"] 305.6 [1'] 50[2"]35[13/8"]386.5[1'-31/4"]50[2"]50[2"]35[13/8"]50[2"]50[2"] 571.5[1'-101/2"] 255.6 [10 1/8"] 50 [2"] 57.2 [2 1/4"]28.4 [1 1/8"]100.8 [4"] 200[77/8"] ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C M10 Bolt Set U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C Aluminum angle 50x50x3 50x110x3 SS Angles 3mm aluminum plate both sides Aluminum Tube 2"x2"x1/8" 3 layers 3/4" FR plywood fasten together with 2 - #8 x 2" long wood screws at 12" oc 3 layers plywood fasten to steel studs with 3 - #8 x 2" long screws 688.8 [2'-3 1/8"] to Grid Line UU.9 UU.9 3 layers plywood fasten to steel studs with 3 - #8 x 2" long screws 3 layers plywood fasten to steel studs with 3 - #8 x 2" long screws 100 [3 7/8"] 50 [2"] ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C Aluminum angle 50x50x3 3mm aluminum plate both sides Aluminum Tube 2"x2"x1/8" 50.8 [2"] 10 [3/8"]49.2 [1 7/8"] M10 threaded rod w/ nut and 25mm Dia. washer Steel Studs to be designed to support the following factored load at anchor locations Vert. = 0.7 kN (Downwards) Hor. = 1.7 (Inward or Outward) Aluminum Holding Plate 20mm Dia. 6mm thick Aluminum Holding Plate 20mm Dia. 6mm thick (Identical to the one used in TPO phase 1) (Identical to the one used in TPO phase 1) (MP4) 3mm Perforated Aluminum Sheet DATE DRAWING NUMBER DRAWING TITLE VERSION VERSION DATE DESCRIPTION 00 03 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 SD - 19 Section Detail DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) 1/2 @ ARCH C (24'' x18'') REFERENCE DRAWINGS A13-01, A13-01C, A13-03, A13-04, A13-08 KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple 20 Jul 2018 01 01 20 Jul 2018 Issued For Approval NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410 or 300 series if exposed. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy=110MPa). -LePage construction adhesive to be applied and cured as per manufacturers instructions. 124' - 3'' T/O FRAMING 50 [2"]304.8 [1']152.4 [6"] 3 [1/8"] 457.2 [1'-6"] ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C M10 Bolt Set U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C Aluminum angle 2"x6"x1/8" 50x110x3 SS Angles 3mm aluminum plate both sides Aluminum Tube 2"x6"x1/8" 3 layers 3/4" FR plywood fasten together with 2 - #8 x 2" long wood screws at 12" oc 3 layers plywood fasten to steel studs with 3 - #8 x 2" long screws 3mm Perforated Aluminum Sheat 3 layers plywood fasten to steel studs with 3 - #8 x 2" long screws 3 layers plywood fasten to steel studs with 3 - #8 x 2" long screws 50.8[2"]50[2"] ST6.3(No14) DIN7976-C Aluminum angle 2"x6"x1/8" 508.4[1'-8"]228.6[9"] ST6.3(No14) DIN7976-C Aluminum angle 2"x6"x1/8" 50.8[2"]50[2"]50.4[2"] 994.3 [3'-3 1/8"] to Grid Line V.1 Aluminum Tube 2"x6"x1/8" M10 threaded rod w/ nut and 25 Dia. washer Aluminum Holding Plate 20mm Dia. 6mm thick Aluminum Holding Plate 20mm Dia. 6mm thick Steel Studs to be designed to support the following factored load at anchor locations Vert. = 0.7 kN (Downwards) Hor. = 1.7 (Inward or Outward) DATE DRAWING NUMBER DRAWING TITLE VERSION VERSION DATE DESCRIPTION 00 11 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 SD-26 Section Detail DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) 1/16 @ ARCH D (36'' x24'') REFERENCE DRAWINGS KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple A12-01, A12-01A, A12-01B, A12-03, A12-05, A12-07 20 Jul 2018 01 01 20 Jul 2018 Issued For Approval NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410 or 300 series if exposed. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy=110MPa). -LePage construction adhesive to be applied and cured as per manufacturers instructions. -Dimensions to be verified on site 143.4 [5 5/8"] minimum from outer edge of wall 170 [6 3/4"] M10 Bolt Set 9.8 [3/8"] 18.6 [3/4"]50.8 [2"]101.6 [4"]15.9 [5/8"] 15.9[5/8"]101.6[4"]50.8[2"]18.6[3/4"] 9.8[3/8"] 50.8[2"] 50.8 [2"] 305.6[1'] 110[43/8"]256.2[101/8"]50[2"]3[1/8"] 50 [2"] 50[2"] 143.4[55/8"] 50[2"]127[5"]50[2"] 502 [1'-7 3/4"] 502[1'-73/4"]50.8[2"] 50.8 [2"]50 [2"] 50 [2"] 50[2"] 42[15/8"] 42 [1 5/8"] 305.6 [1'] 50 [2"] 3 [1/8"] 3 [1/8"] 3 [1/8"] 42[15/8"] 42 [1 5/8"] ST6.3(No14) DIN7976-C ST6.3(No14) DIN7976-C M10 Bolt Set M10threadedRod ST6.3(No14) DIN7976-C 50x50x3 Aluminum Tube EIFS By Others 3mm Aluminum Angle 35 x3mm (1 3 8'' x 1 8'') Aluminum plate pre-connected to slats U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C U bracket connected to vertical tube through 3 screws ST6.3(No14) DIN7976-C Wood blocks from steel stud to steel stud designed,supplied and installed by others Blocking and steel studs to able to support the following factored loads: Vert.= 0.7 kN (downwards) Hor.= 1.7 kN (inward or outward) 50x110x3 SS angle (height 150mm) 50x110x3 SS angle (height 150mm) 50x110x3 SS angle (height 150mm) Neutral Barrier between SS angle and aluminum tube to avoid corrosion Neutral Barrier between SS angle and aluminum tube to avoid corrosion 2''x4''x 1/8'' Aluminum Slat Nut & 25mm Dia Washer Aluminum U-Shaped Cap Plate Outside visible side of bracket is lapped as shown - Gastket all locations through envelope DATE 16 MAY 2018 DRAWING NUMBER DRAWING TITLE VERSION 01 VERSION DATE DESCRIPTION 00 06 Apr 2018 Issued For Approval PROJECT TITLE SCALE 1/2'' = 1'' @ ARCH C (24'' x18'') PD-02 Plan Detail (Screen) DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) Project ID 15124.03 REFERENCE DRAWINGS B9-GA8-North East KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS NOTES - Primary Units are in mm - All Cladding surfaces had been coordinated to be 2'' outer of the provided sheathing METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). 01 16 May 2018 Issued For Approval 127.3 [5"] 304.7 [1'] 101.6[4"] 76.2 [3"] 583.3[1'-11"] 101.6 [4"] 25[1"] 151.2[6"] 25.4[1"] 50. 8[2"] 4 mm Aluminum Composite Panel Sheathing by Others Air & Moisture Barrier by Others Membrane on Sheathing by Others 50.8 [2"] 101.6[4"] 126' - 7'' T/O PARAPET 126' - 5'' T/O STEEL Seal 124' - 4'' T/O ACP ZONE 1035.3 [3'-4 3/4"] to AXIS 17C 44 [1 3/4 "] #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. #10 Grade 410 Stainless Steel self-drilling screw #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. Wood Blocking by Others Wood Blocking by Others #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. #10 Grade 410 Stainless Steel self-drilling screw #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. Steel Studs by Others (assumed 20GA. thickness at 16'' OC.) #10 Grade 410 Stainless Steel self-drilling screw #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. Vertical Joint Profile Riveted on ACP (Rivets Finish to match profiles) Vertical Joint Profile Riveted on ACP (Rivets Finish to match profiles) Trim Flashing 3mm "Z" Shape aluminum profile Drainage Hole @ 4' O.C. Drainage Hole @ 4' O.C. DATE 16 MAY 2018 DRAWING NUMBER DRAWING TITLE VERSION 01 VERSION DATE DESCRIPTION 00 06 Apr 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 B9-SD10 Section Detail (Parapet) DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) 1/2'' = 1'' @ ARCH D (36'' x24'') REFERENCE DRAWINGS 01/B9-GA11 KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS NOTES - Primary Units are in mm - All Cladding surfaces had been coordinated to be 2'' outer of the provided sheathing METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy = 110MPa). 01 16 May 2018 Issued For Approval 44[13/4"]101.6[4"] 15[5/8"] 50.8 [2"] 15 [5/8"] 42 [1 5/8"] 50.8 [2"] 431.3 [1'-5"] 40.9[15/8"] 112.4[43/8"] #10 Grade 410 Stainless Steel self-drilling screw #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. 3mm "Z" Shape aluminum profile #10 Grade 410 Stainless Steel self-drilling screw Pressure Cap 3mm "Z" Shape aluminum profile Shiming Drip Profile Pressure cap Drainage Hole 6x30mm 35[13/8"] 31 [1 1/4"] 487.8 [1'-7 1/4"] Drainage Hole 6x30mm #10 Grade 410 Stainless Steel self-drilling screw @ 16" oc #8 Grade 410 Stainless Steel self-drilling screw @ 12" oc #10 Grade 410 Stainless Steel self-drilling screw 387.3[1'-31/4"] 116' - 11'' T/O PARAPET Min. 2% Slope #10 Grade 410 Stainless Steel self-drilling screw #10 Grade 410 Stainless Steel self-drilling screw @ 16" oc #10 Grade 410 Stainless Steel self-drilling screw #10 Grade 410 Stainless Steel self-drilling screw #10 Grade 410 Stainless Steel self-drilling screw @ 16" oc #10 Grade 410 Stainless Steel self-drilling screw @ 16" oc #10 Grade 410 Stainless Steel self-drilling screw #8 Grade 410 Stainless Steel self-drilling screw @ 12" oc #8 Grade 410 Stainless Steel self-drilling screw @ 12" oc #10 Grade 410 Stainless Steel self-drilling screw @ 16" oc 2mm "U" Shape aluminum profile (CONTINUOUS) 4 mm Aluminum Composite Panel (MP2) DATE DRAWING NUMBER DRAWING TITLE VERSION VERSION DATE DESCRIPTION 00 03 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 15124.03 SD - 21 Section Detail DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) 1/2 @ ARCH C (24'' x18'') REFERENCE DRAWINGS KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple A13-01, A13-01B, A13-03, A13-05, A13-09 20 Jul 2018 01 01 20 Jul 2018 Issued For Approval NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectural drawings and GC/Framing -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410 or 300 series if exposed. -All Bolts to be grade 304. -All aluminum components to be grade 6063 T5 (Fy = 110MPa). -All Stainless steel components to be grade 304 (Fy = 207MPa). -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy=110MPa). -LePage construction adhesive to be applied and cured as per manufacturers instructions. -Dimensions to be verified on site 184.1[71/4"] 31.8[11/4"]31.8[11/4"] 152.3[6"] 50.8 [2"] FIBER CEMENT PANEL 7 1 4'' x 5 16'' OVERLAP 2mm VERTICAL ALUMINUM PROFILE at 16'' O.C. SHIMMING 5 8'' Fibreglass Sheathing by Others Air & Moisture Barrier by Others 119' - 10'' T/O PARAPET 119' - 8'' T/O STEEL 117' - 6'' U/S DECK 422.4 [1'-4 5/8"] to AXIS SS.1 SS1 METAL FLASHING CAP by OTHERS CAULKING by OTHERS Steel Studs by Others (assumed 20GA. thickness at 16'' OC.) SHIMMING #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. 7.2 [9/32"] #8 Grade 410 Stainless Steel self-drilling screw at 16'' OC. #8 Grade 410 Stainless Steel self-drilling screw at 16'' OC. #8 Grade 410 Stainless Steel self-drilling screw at 16'' OC. #8 Grade 410 Stainless Steel self-drilling screw at 16'' OC. #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. 2mm VERTICAL ALUMINUM PROFILE at 16'' O.C. Steel Studs by Others (assumed 20GA. thickness at 16'' OC.) 25[1"]7.2[1/4"] SHIMMING Partial Plan Detail A Partial Plan Detail A Partial Plan Detail A-A FIBER CEMENT PANEL 7 1 4'' x 5 16'' FIBER CEMENT PANEL 7 1 4'' x 5 16'' 5 8'' Fiberglass Sheathing by Others Air & Moisture Barrier by Others DATE 16 MAY 2018 DRAWING NUMBER DRAWING TITLE VERSION 01 VERSION DATE DESCRIPTION 00 06 Apr 2018 Issued For Approval PROJECT TITLE SCALE SD-04 Section Detail (Parapet) 1/2'' = 1'' @ ARCH C (24'' x18'') DRAWN by S.F. CHECKED by E.F. TORONTO PREMIUM OUTLETS (Phase 2B) Project ID 15124.03 REFERENCE DRAWINGS KEY PLAN 01/B9-GA5 OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14-15 S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TRUST CONSTRUCTION - MANAGEMENT BROCCOLINI PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIVE THE SPECIFICATIONS NOTES - Primary Units are in mm - All Cladding surfaces had been coordinated to be 2'' outer of the provided sheathing METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth Finish -MP2: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpolic Fire Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpolocn Fire Rated), Kynar 500 / Hylar 500 – Custom Colour to match Anodized Storefront – Smooth Finish -MP7: Perforated Metal Screen, Woven Wire Mesh, Square Wave, Aluminum Alloy, Intercrimp weave const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 8530 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis of Design Allura Stained Lap Siding, Traditional Cedar Texture, Colour Maple NOTES -All composite aluminum panels to be by Alpolic Fire Rated, 4 mm total thickness (2 layers 0.5 mm THK. Aluminum). -All self drilling screws to penetrate min. 3 pitches of thread into steel member., min. edge distance 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410. -All aluminum extrusion carrier components to be min. 2mm thick and grade 6063 T5 (Fy = 110MPa). 01 16 May 2018 Issued For Approval 33 [1 1/4"] 33 [1 3/8"] 33[11/4"] 33[13/8"] 31 [1 1/4"] 31[11/4"] 31 [1 1/4"] 31[11/4"] 44 [1 3/4"] 25[1"] 222[83/4"] 243 [9 5/8"] 51 [2"] 50.8[2"] 50.8 [2"] 50.8[2"] Sheathing by Others Sheathing by Others Sheathing by Others #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. #8 Grade 410 Stainless Steel self-drilling screw at 12'' OC. #10 Grade 410 Stainless Steel self-drilling screw at 16'' OC. 4 mm Aluminum Composite Panel MP2 4 mm Aluminum Composite Panel MP1 4 mm Aluminum Composite Panel MP1 4 mm Aluminum Composite Panel MP1 482[1'7'']toGridLine18.2 1068 [3' 6''] to Grid Line VV.4 LePage PL9000 construction adhesive, refer to GA03 & GA04 for panel locations DATE DRAWING NUMBER DRAWING TITLE VE VERSION DATE DESCRIPTION 00 03 Jun 2018 Issued For Approval PROJECT TITLE SCALE Project ID 151 PD-05 Plan Detail DRAWN by S.F. CHECKED b TORONTO PREMIUM OUTLETS (Phase 1/2 @ ARCH D (36'' x24'') REFERENCE DRAWINGS A13-01, A13-01A, A13-03, A13-05, A13-09, A1 KEY PLAN OWNERS & DEVELOPERS ARCHITECT - CONSULTANT CONTRACTOR CLADDING SYSTEM W 14- S I M O NPREMIUM OUTLETS CALLOWAYREAL ESTATE INVESTMENT TR CONSTRUCTION - MANAGEMENT BROCCOLIN PETROFFPARTNERSHIP ARCHITECTS DESIGN ARCHITECT COLLABORATIV THE SPECIFICATIONS METAL PANELS -MP1: 4 mm Aluminum Composite Panel (Alpo Rated), Kynar 500 / Hylar 500 – Slate Grey - Sm Finish -MP2: 4 mm Aluminum Composite Panel (Alpo Rated), Kynar 500 / Hylar 500 – Dove Grey – Smooth Finish -MP3: 4 mm Aluminum Composite Panel (Alpo Rated), Kynar 500 / Hylar 500 – Medium Bronze – Smooth Finish -MP4: Perforated Metal Screen, Alum. Type 3003-H14, 0.125 Gauge, C Anodized Finish, Round Holes ¼’’ on 5/16’’ centers, Staggered Pattern, 58% Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum Tube Frame) -MP5: Horizontal Slat Screen, Powder Coated Aluminum (Colour Medium Bronze), MTD to 2’’x2’’ Anodized Aluminum Tube Framing -MP6: 4 mm Aluminum Composite Panel (Alpo Fire Rated), Kynar 500 / Hylar 500 – Custom C to match Anodized Storefront – Smooth Finish -A1, A2: 4 mm Aluminum Composite Panel for canopies’ cladding MASONRY -B1: Thin Brick Veneer System, Running Bond - Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W) -B2: Thin Brick Veneer System, Belden No. 853 (2-1/4''Hx3/4''Dx7-5/8''W) -S1: Cast Stone Sill CLADDING -CL1: Fiber Cement Siding (6'' Exposure), Basis Design Allura Stained Lap Siding, Traditional Ce Texture, Colour Maple 20 Jul 2018 01 20 Jul 2018 Issued For Approval NOTES - Primary Units are in mm - Sheathing to be coordinated with Architectu drawings and GC/Framing -All composite aluminum panels to be by Alp Fire Rated, 4 mm total thickness (2 layers 0. THK. Aluminum). -All self drilling screws to penetrate min. 3 pi of thread into steel member., min. edge dista 1.5xdia., min. spacing 2.5xdia. -All screws to be stainless steel grade 410 or series if exposed. -All Bolts to be grade 304. -All aluminum components to be grade 6063 (Fy = 110MPa). -All Stainless steel components to be grade 3 (Fy = 207MPa). -All aluminum extrusion carrier components min. 2mm thick and grade 6063 T5 (Fy=110 -LePage construction adhesive to be applied cured as per manufacturers instructions. -Dimensions to be verified on site
  • 12. 52013-2018 Assignment of: -New Aluminum Cladding System development (H-2040) -Tender Stage Estimation -Shop Drawings -Bill of Materials -Fabrication Drawings -Installation Drawings Scope of Work: -Ceramic Panels Cladding -Enamel Porcelain Panels Cladding -Stainless Steel Panels Cladding HIGHWAY 407 STATION Toronto, Canada
  • 13. 0 1 2m S7S6S5 198.60 FINISH BUS TERMINAL FLOOR FINISH ENTRANCE FLOOR 193.35 +189.07 FINISH WEST CONCOURSE FLOOR WEST CONCOURSE UNPAID AREA SOUTH WING INTERNAL BUS TERMINAL ESCALATOR NOSING LINE BEYOND SS ESCALATOR BALUSTRADE BEYOND - BY ESCALATOR CONTRACTOR ESCALATOR 8 BEYOND 5338 1200 PORCELAIN ENAMEL PANELS TO BE 1220 A.F.F. MIN. AT STAIR 12/13 LANDINGS PORCELAIN ENAMEL PANELS 01 SD-02 DECORATIVE GLASS 8625 8746 3709 S8 S9 (OHLFCCjv) (OHLFCCjv) 1ESCALATORS 5 & 6 ELEVATION PARTIAL STAIR 12 & 13 SECTION 01 S-02 02 S-02 see P01 2350619 619 619 619 619 619 619 619 1766 1806 1806 1806 1506 1142 850 SECTIONTURNLINE 191.214 1000 F.F. LEVEL 03 S-02 130 150° 6909 1025 150 ±465 PORCELAIN ENAMEL PANELS (see 01/S-04) SIDEWALL STEP LIGHT 300x150mm (OHLFCCjv) (Centered Horizontally on Panels) 1025 HANDRAIL (OHLFCCjv) 150° 150° 150° 619 1415 50 1068 1431 2400 619 619 619 619 619 1220 50 619 619 619 1050 150 619 10 10 10 275 260 Architectural REV. A REV. B NOTES: DESIGN DATE : - -- ARCHITECTURAL TORONTO- SPANDINA SUBWA HIGHWAY 407 Project Title: Scale : nts EF Project No: 1302 -Ref. dwg No:A33-1-A7313 Drawing T Escalator 5 & 6 partial stair 12 & Product: Porcelain Enam Section: 07 44 16 Name of product: PEP S Sheet manufacturer: 1mm Contract Number: A35-2 LEGEND: * The dimensions of stainless substructure will be verified an to the heavy substructure's fin 1. Porcelain Enamel Panel 2. a. Stainless steel Clip ,type 22x12x1.27mm (part len b. Stainless steel Clip,type 15x12x1.27mm (part len c. Stainless steel Clip,type 34x12x1.27mm (part len 3. Stainless steel angle 20x2 4. a. Steel Studs 50x35x1mm b. Steel Studs 70x35x1mm 5. Screw ST4.2 (No8) stainle 6. HILTI Kwik Flex Screw#10 UCAN fasteners TRH 1034 7. Rivet No4 stainless steel D 8. Backer Rod 9. Sealant (to be tooled to co 10. Stainless Steel Edge Trim -All dimensions are in mm on site before fabrication -Stainless steel clips are to o.c. vertically and horizon perimeter of each porcelai -Porcelain enamel panel w -Min. 2 #8 screws per stain steel stud. -Before to begin works, coo Structural Subcontractor, C system, escalators, art glas lighting system, terrazzo ba will be necessary. 2 50.0 50 mm10 20 100 10010 14 1750 35 01DETAIL SECTION 67 8 9 5 4a 1 2b 7 2b 171 100 02DETAIL SECTION 50 35 15 68 2 50.0 50 mm10 20 100 1 2b 4a 6 Foam tape DETAIL SECTION 03DETAIL SECTION 76 15 67 50 100 6 2 50.0 50 mm10 20 100 1 2b 4a 6 DETAIL SECTION 10 100 50 18 15 67 2 50.0 5010 20 1 4a 2b 7 9 8 2b DETAIL SECTION 10 18 15 68 50 2 50.0 50 mm10 20 100 2b 1 5 9 8 01SECTION ESCALATOR SIDE CLADDING AT TERRAZZO BASE 0 100 200mm see E-01 20 10 35 152 10 35 38 35 35 50 76 20 7038 35 100 100 100 varies 45 150 1025 02 SD-02 03 SD-02 TERRAZZO FINISH (OHLFCCjv) 4b 4a 1 2a 9 10 Handrail (OHLFCCjv) SS Panels (OHLFCCjv) 02SECTION ESCALATOR SIDE CLADDING AT TERRAZZO BASE 0 100 200mm see E-01 TERRAZZO FINISH (OHLFCCjv) 20 100 150 152 10 35 45 varies 7038 35 100 04 SD-02 1 4b 2a 10 9 Handrail (OHLFCCjv) SS Panels (OHLFCCjv) Galvanized Steel Angle 76x76x6.4mm (OHLFCCjv) BICYCLE CURB SEC TYPICAL AT ESCALATOR BALUSTRADE 152 10 35 45 7038 35 100 20 100 1806 Handrail (OHLFCCjv) 9 10 2a 1 70 35 38 6 Galvanized Steel An 76x76x6.4mm (OHLFCCjv) OUTLINE OF HANDRAIL BEHIND OHLFCCjv OUTLINE OF FLEXIBLE ESCALATOR HANDRAIL (OHLFCCjv) 10 619 10 618 2 50.0 50 mm10 20 100 100 100 100 70 35 35 5035 4b 5 9 8 3 1 2 50.0 50 mm10 20 100 10010 14 1750 35 01DETAIL SECTION 67 8 9 5 4a 1 2b 7 2b 171 100 02DETAIL SECTION 50 35 15 68 2 50.0 50 mm10 20 100 1 2b 4a 6 Foam tape DETAIL SECTION 03DETAIL SECTION 76 15 67 50 100 6 2 50.0 50 mm10 20 100 1 2b 4a 6 DETAIL SECTION 10 100 50 18 15 67 2 50.0 5010 20 1 4a 2b 7 9 8 2b DETAIL SECTION 10 18 15 68 50 35 2 50.0 50 mm10 20 100 2b 1 4 5 9 8 2 50.0 50 mm10 20 100 10010 14 1750 35 01DETAIL SECTION 67 8 9 5 4a 1 2b 7 2b 171 100 02DETAIL SECTION 50 35 15 68 2 50.0 50 mm10 20 100 1 2b 4a 6 Foam tape DETAIL SECTION 03DETAIL SECTION 76 15 67 50 100 6 2 50.0 50 mm10 20 100 1 2b 4a 6 04DETAIL SECTION 10 100 50 18 15 67 2 50.0 50 mm10 20 100 1 4a 2b 7 9 8 2b 05DETAIL SECTION 10 18 15 68 50 35 2 50.0 50 mm10 20 100 2b 1 4a 5 9 8 2 50.0 50 mm10 20 100 10010 14 1750 35 01DETAIL SECTION 67 8 9 5 4a 1 2b 7 2b 171 100 02DETAIL SECTION 50 35 15 68 2 50.0 50 mm10 20 100 1 2b 4a 6 Foam tape DETAIL SECTION 03DETAIL SECTION 76 15 67 50 100 6 2 50.0 50 mm10 20 100 1 2b 4a 6 04DETAIL SECTION 10 100 50 18 15 67 2 50.0 50 mm10 20 100 1 4a 2b 7 9 8 2b 05DETAIL SECTION 10 18 15 68 50 35 2 50.0 50 mm10 20 100 2b 1 4a 5 9 8 2 50.0 50 mm10 20 100 10010 14 1750 35 01DETAIL SECTION 67 8 9 5 4a 1 2b 7 2b 171 100 02DETAIL SECTION 50 35 15 68 2 50.0 50 mm10 20 100 1 2b 4a 6 Foam tape DETAIL SECTION 03DETAIL SECTION 76 15 67 50 100 6 2 50.0 50 mm10 20 100 1 2b 4a 6 04DETAIL SECTION 10 100 50 18 15 67 2 50.0 50 mm10 20 100 1 4a 2b 7 9 8 2b 05DETAIL SECTION 10 18 15 68 50 35 2 50.0 50 mm10 20 100 2b 1 4a 5 9 8 ENAMEL
  • 14. DETAILS - E.A.S. PLAN PLAN DETAIL 481064825 25 695 CLEAROPENING 300 MASONRY OPENING 280 INSIDE ENCLOSURE 265 RECESS 100 5 10550 25 60 80 TRIP SWITCH 01 01 63 63 45 280 DOOR WIDTH LOCATEDOORSTOP TOSUITDOORIN CLOSEPOSITION 50 SECTION - E.A.S. 250 OUTSIDEENCLOSURE 675 INSIDEMAINENCLOSURE 300 PANEL 240 TRIPSWITCHOPNG. 3030 375 TELEPHONECABINETD00R 2070 TOFIN.FLR. 265 RECESS 03 03 02B 02A 02C 02B 02A 02C 150 300 MASONRY OPENING 280 INSIDE ENCLOSURE 250 OUTSIDEENCLOSURE 10 16 25 PLYWOOD SPACERS (OHLFCCjv) SS TEL.MOUNTING BOARDSUPPORT ANGLE (OHLFCCjv) TEL.MOUNTING BOARD (OHLFCCjv) SS DOOR W/CONCEALED SS PIANO HINGE (OHLFCCjv) 1.6THK SS ENCLOSURE (OHLFCCjv) 50 180 TO BACK OF BOARD TRIP SWITCH MOUNTING BRACKETS (OHLFCCjv) 1 2 4 5 CONC STRUCTURE/ MASONRY WALL1 48X32X1061 DIA SS FIN. RING,CUT OPENING IN WALL FINISH TO FIT PLYWOOD SHIMS, AS REQ. (OHLFCCjv) PLYWOOD SPACER AS REQ. (OHLFCCjv) 1.6THK. SS ENCLOSURE SECURED TO BACK WALL PROVIDE FASTENERS.(OHLFCCjv) 25x20x365LG x1.6THK SS DOOR STOP (1-OFF) FASTEN TO INSIDE OF MAIN ENCLOSURE 275W x355H x 20THK TELEPHONE MOUNTING BOARD TO SUPPORT ANGLES (OHLFCCjv) 225 x 25 x 300LG x 1.6 THK SS PHONE BOARD SUPPORT ANGLE (2-OFF) FASTEN TO BOTH SIDES (INSIDE OF MAIN ENCLOSURE) (OHLFCCjv) 400 1010 PLYWOOD SPACERS (OHLFCCjv) 125 x 45 OPENING TOP & BOTTOM OF ENCLOSURE (OHLFCCjv) 100 x50 X260LG 1.6THK SS MOUNTING BTACKET WELDED TO BOTH SIDES (INSIDE) ENCLOSURE (OHLFCCjv) 280W x 300H x 1.6THK SS PANEL W/ CUT TO SUIT TRIP SWITCH 25 SELF FLANGE (INTERNAL) ALL AROUND PANEL, WELD PANEL TO MAIN ENCLOSURE (OHLFCCjv) 1 1 02 01 1 695 RECESS 160 2070TOFIN.FLOOR 1060TOFINFLR. DETAILS - E.A.S. 03 SS TELEPHONE CABINET (OHLFCCjv) 240 2 8 11 5 8 11 5 Design loads (internal & external panels) Wind loads: 1.25kPa positive and negative pressure. Dead loads: 0.313kPa (Ceramic Panel). Material properties Ceramic panels as per AGROB BUCHTAL Manufacturer Specs. Stainless steel type 304: yield strength 210 Mpa. (Shapes: ASTM A276, Sheet & Plate: ASTM A666) 180 1 CONCRETE OR CMU WALL CLADDING CORNER-SECTION S3 1 2 8 4 5 14 180 8 180 4 5 11 3 2 11 1 1200 1192 10 CLADDING SECTION AA(P3) CLADDING DETAIL FOR 1200mm TILES PLAN - P3 A A CONCRETE OR CMU WALL 8 8 200 12 10 200 8 150 2 11 1 CONCRETE OR CMU WALL CLADDING CORNER-SECTION S3a 90.0° 150 EXTERNAL CORNER- PLAN EXTERNAL CORNER- PLAN 180 11 2 11 8 11 STAINLESS STEEL ANGLE (CONTINUOUS) 120x120x1.35mm 90.0° 19 19 CLADDING CORNER-SECTION S2 INTERNAL CORNER- PLAN SHIM AS REQ. SHIM AS REQ. STAINLESS STEEL ANGLE (PART 100mm) 120x120x2.75mm STAINLESS STEEL ANGLE (CONTINUOUS) 100x100x1.35mm STAINLESS STEEL ANGLE (PART 100mm) 120x120x2.75mm 150 typ. 150 typ. 90.0° continuous angle 120x120mm 16 16 120x120mm CONCRETE WALL R15 8 4 5 11 2 1 16 9 19 1313 1313 13 13 1313 13 13 13 10.0° CLADDING CORNER-SECTION INTERNAL CORNER- PLAN (CONCAVE WALL) 13 8 4 5 1111 11 2 1 19 Architectural Drawing REV. A REV. B NOTES: DESIGN DATE : 08 AUG 2014 - -/-/- -- --/--/-- ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS TORONTO-YORK SPANDINA SUBWAY EXTENSION HIGHWAY 407 STATION Project Title: Scale : nts EF Project No:1302 Drawing Title : Generic Details 03 Ceramic Tile Panel system Dwg No: GD-05 Product: Ceramic Tile Panel System Section: 09 35 00 Contract Number: A35-26 Name of product: AGROB BUCHTAL K-20 SYSTEM Tile manufacturer: 20mm AGROB BUCHTAL Design loads Wind loads: 1.25kPa positive and negative pressure. Dead loads: 0.313kPa (Ceramic Panel). Material properties Ceramic panels as per AGROB BUCHTAL Manufacturer Specs. Stainless steel type 304: yield strength 210 Mpa. (Shapes: ASTM A276, Sheet & Plate: ASTM A666) -Ref. dwg No:A33-1-A9101 Sh No: 319 -All dimensions are in mm and will be check on site before fabrication. -Before to begin works coordination between Structural Subcontractor,Ceramic panel tile system and M&E will be necessairy. -All wall brackets are to be spaced at 700mm o.c. vertically. -Classic system rail K20 to be fastened to vertical subgirt with 2#rivets 4x10 mm at 300mm o.c. -For every continuous vertical subgirt, place two rivets through the round holes at the lower bracket. At the rest brackets place 2 rivets through the oval holes. * The dimensions of stainless steel parts will be verified & adjusted according to the substructure's final edge. 1. Ceramic Panel Tile System Agrob Buchtal 20mm 2. Classic System Rail K20 (Agrob) 3. Stainless steel joint profile thickness 0.7mm 4. Wall bracket,stainless steel angle* type"L" thickness 2.75mm 5. Stainless Steel vertical subgirt continuous angle* thickness 1.35mm 6. Stainless steel perimeter frame with thickness 0.7mm,shapes & dimensions varies 7. Stainless steel clip for perimeter frame 8. a.For concrete: Hilti Exp. anchor KB3 3/8" x 3" LT stainless steel #304 / ITW or equal b. For masonry block: Hilti Sleeve anchor HLC-HX 3/8" x 1-7/8" stainless steel / ITW or equal 9. Tek screw 1/4'' x 1 3/4'' 10.Screw ST 4.2(No8) DIN7981C stainless steel 11.Rivet No4 DIN 7337 stainless steel 12.Hexagon bolt M10 stainless steel L:60mm with hexagon nut. 13.Bituminous paint: "Mel Roll" or equal 14.Reserved 15.Lexcor Air Vapour Barrier 16.Stainless steel part* thk.0.70mm 17.Reserved 18.Insulation:Mineral Fiber Board Roxul RXL60@96Kg/m3 19.Stainless steel corner trim 20.Perforated Ceramic Tile System Agrob Buchtal 20mm, including acoustic backing LEGEND: SECTION-DETAIL see P13,P13A 01 CERAMIC PANEL AT PLATFORM LEVEL ESCALATOR SUPPORT WALLS CONCRETE WALL OR CONC. BLOCK WALL STRUCTURAL ANGLE (OHLFCCjv) 1 TYPICAL HYDRANT FIXTURE (OHLFCCjv) SECTION-DETAIL see E11 02 RECESSED HYDRANT 03 RECESSED LIGHT FITTING - SECTION- TYP. see E-17 SECTION DETAIL 1 2 8 4 5 LIGHT FITTING (OHLFCCjv) CONCRETE OR CMU WALL 04 S-28(1) 280 10 180 1010 120 6 400 170 100 150 124 300 VARIES 20 6550235 350 SATIN SS PANEL SYSTEM, FIXED ON 50MM HSS FRAME (OHLFCCjv) 20 180 10 8 11 4 5 2 1 11 SECTION-DETAIL see E30 04 6 13 84 13 13 CONCRETE WALL (ESCALATOR SUPPORT) CONCRETE BLOCK WALL 1 2 45 8 11 150 150 624 632 150 typ. 13 3 81* 484 SECTION-DETAIL see P13,P13A 05 CERAMIC PANEL AT PLATFORM LEVEL ESCALATOR SUPPORT WALLS 8 8 8 9 Architectural Drawing REV. A REV. B NOTES: DESIGN DATE : 20 Nov 2014 - -/-/- -- --/--/-- ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS TORONTO-YORK SPANDINA SUBWAY EXTENSION HIGHWAY 407 STATION Project Title: Scale : nts EF Project No :1302 -Ref. dwg No:A33-1-A9101 Sh No: 319 Drawing Title : Interior section details Dwg No: S-20 Product: Ceramic Tile Panel System Section: 09 35 00 Contract Number: A35-26 Name of product: AGROB BUCHTAL K-20 SYSTEM Tile manufacturer: 20mm AGROB BUCHTAL -Ref. dwg No:A33-1-A9105 Sh No: 323 -Ref. dwg No:A33-1-A9155 Sh No: 334 -Ref. dwg No:A33-1-A9157 Sh No: 336 -All dimensions are in mm and will be check on site before fabrication. -Before to begin works coordination between Structural Subcontractor,Ceramic panel tile system and M&E will be necessairy. -All wall brackets are to be spaced at 700mm o.c. vertically. -Classic system rail K20 to be fastened to vertical subgirt with 2#rivets 4x10 mm at 300mm o.c. -For every continuous vertical subgirt, place two rivets through the round holes at the lower bracket. At the rest brackets place 2 rivets through the oval holes. * The dimensions of stainless steel parts will be verified & adjusted according to the substructure's final edge. 1. Ceramic Panel Tile System Agrob Buchtal 20mm 2. Classic System Rail K20 (Agrob) 3. Stainless steel joint profile thickness 0.7mm 4. Wall bracket,stainless steel angle* type"L" thickness 2.75mm 5. Stainless Steel vertical subgirt continuous angle* thickness 1.35mm 6. Stainless steel perimeter frame with thickness 0.7mm,shapes & dimensions varies 7. Stainless steel clip for perimeter frame 8. a.For concrete: Hilti Exp. anchor KB3 3/8" x 3" LT stainless steel #304 / ITW or equal b. For masonry block: Hilti Sleeve anchor HLC-HX 3/8" x 1-7/8" stainless steel / ITW or equal 9. Tek screw 1/4'' x 1 3/4'' 10.Screw ST 4.2(No8) DIN7981C stainless steel 11.Rivet No4 DIN 7337 stainless steel 12.Hexagon bolt M10 stainless steel L:60mm with hexagon nut. 13.Bituminous Paint: "Mel-Roll LM" or equal 14.Reserved 15.Lexcor Air Vapour Barrier 16.Stainless steel part* thk.0.70mm 17.Reserved 18.Insulation:Mineral Fiber Board Roxul RXL60@96Kg/m3 19.Stainless steel corner trim 20.Perforated Ceramic Tile System Agrob Buchtal 20mm, including acoustic backing LEGEND: Design loads (internal & external panels) Wind loads: 1.25kPa positive and negative pressure. Dead loads: 0.313kPa (Ceramic Panel). Material properties Ceramic panels as per AGROB BUCHTAL Manufacturer Specs. Stainless steel type 304: yield strength 210 Mpa. (Shapes: ASTM A276, Sheet & Plate: ASTM A666) CERAMICS