2. 12017-present
Assignment of:
-Shop Drawings
-Fabrication Drawings
-Installation Drawings
Scope of work:
-Aluminum Curtain Walls
-Aluminum Doors & Windows
-Aluminum Window Walls
-Glass Cladding
-Aluminum Fins
-Aluminum Slab Covers
250
5th AVENUE
New York, USA
3.
4. 12.7 [1/2"]
Clear Opening=977.9 [3'-2 1/2"] Clear Opening=466.7 [1'-6 3/8"]
152.4[6"]171.5[63/4"]
323.8[1'-03/4"]
406.4[1'-4"]
688.7[2'-31/8"]
342.6 [1'-1 1/2"] R.O.=2827 [9'-3 1/2"]
142.4 [5 5/8"] 176.4 [7"]
1574 [5'-2"]
SLAB COVER Edge Flush
to Brick Wall Edge
SLAB Edge
SLAB COVER Edge Flush
to Brick Wall Edge
SLAB Edge
DT-105
DT-106
sim
sim
DT-128
2876.6 [9'-5 1/4"] to Grid Line 3
E.O.S. 63.5 [2 1/2"]
E.O.S.215.9[81/2"]
140 [5 1/2"]
SLABEdge
82.6[31/4"]
toGridLineE
82.6[31/4"]
GL2
GL1 GL1
GL1A GL1A
GL1
GL1A
T.O.S. 14TH FL
126' - 10"
T.O.S. 15TH FL
136' - 1"
R.O.=2591[8'-6"]
F.D.=2555[8'-45/8"]
433.1[1'-5"]60[23/8"]315[1'-03/8"]60[23/8"]315[1'-03/8"]60[23/8"]403.1[1'-37/8"]60[23/8"]409[1'-41/8"]
BrickWallEdgeBeyond
GL2GL2
457.2[1'-6"]1676.4[5'-6"]457.2[1'-6"]
R.O.=2832 [9'-3 1/2"]
2876 [9'-5 1/4"] to Grid Line 3
T.O.S.1
126' -
FINEdge
[03] TpN- Plan 01
scale 1/8
[01] TpN- ELEVATION
scale 1/8
Max torque
(Nm) 35
Max torque
(Nm) 35
Maxtorque
(Nm)35
Maxtorque
(Nm)35
147.4 [5 3/4"]
18.3[3/4"]
10[3/8"]
7.3 [1/4"]
125.3 [4 7/8"]
46 [1 3/4"]4 [1/8"]
150[57/8"]
46 [1 7/8"] 4 [1/8"]
150[57/8"]
60[23/8"]
339.5[1'-13/8"]
Transom
Window Sash
Window Wall Receptor
Window Frame
Glazing Bead
Window Frame
Glazing
Mineral Wool Insulation 40mm
Aluminum Tray 1.5mm
Aluminum Sheet 2mm
Aluminum Angle 20x20x2 mm
Aluminum Angle 20x20x2 mm
27.1 [1 1/8"] 133 [5 1/4"] 17.3 [5/8"]
T.O.S. 8TH FL
71'- 4"
E
81.8 [3 1/4"] to Grid Line E
Interior Floor Finishes by others
228.6[9"]
Interior Floor Finishes by others
102[4"]
102 [4"]
Steel Studs by others
228.6[9"]
190.5[71/2"]
63.4 [2 1/2"]
Aluminum Fin
190.6 [7 1/2"]
12.7[1/2"]55[21/8"]379.7[1'-3"]19.6[3/4"]32.2[11/4"]75[3"]
58.9 [2 3/8"] 36.5 [1 3/8"] 57 [2 1/4"]
152.4 [6"]
47 [1 7/8"] 30 [1 1/8"] 135 [5 3/8"]
212 [8 3/8"]
75[3"]12.7[1/2"]
Window Investment by others
Line of Slab Covers
Line of Vertical Fins
81.8 [3 1/4"] 152.4 [6"] 158 [6 1/4"]
14.4 [5/8"]
Aluminum Angle 50X50
Aluminum Angle 50X50
Mineral Wool Insulation
Concrete Anchors M10X95 Spacing TBD
Waterproofing Membrane
Concrete Anchors M10X95 Spacing TBD
281.4 [11 1/8"]
87.9[31/2"]
25[1"]
40 [1 5/8"]
Drainage hole:
6x25mm @ 2' o.c.
2%
Project IDDATE 59380
DRAWING NUMBER
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
VERSION DATE DESCRIPTION
CHECKED by ETEM
00
250 5th Ave Hotel - New York
PROJECT TITLE
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
KEY PLAN
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
DT - 109
Type K - Section Detail
21 Apr 2018 Issued For Approval
REFERENCE DRAWINGS
TpK - GA01
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
Etem Window Wall System E86
01
21 Sept 2018
01 Issued For Approval21 Sept 2018
Maxtorque
(Nm)35
Maxtorque
(Nm)35
Max torque
(Nm) 35
152.4 [6"]
50 [2"]
43[13/4"]
5[1/4"]
40[15/8"]
60[23/8"]
75[3"]32[11/4"]40[15/8"]333.9[1'-11/8"]70[23/4"]23[7/8"]
18.2[3/4"]
27.1 [1 1/8"] 133 [5 1/4"] 17.3 [5/8"]
63.5 [2 1/2"]
Transom
Window Sash
Glazing Bead
Window Frame
Window Wall Receptor
Glazing Bead
Aluminum Sill
42[15/8"]
172.4 [6 3/4"] 281.4 [11 1/8"]
T.O.S. 7TH FL
62' - 1"
E
Glazing Bead
81.8 [3 1/4"] to Grid Line E
Aluminum Sheet 2mm
Aluminum Angle 20x20x2 mm
Interior Floor Finishes by others
Aluminum Fin
Window Wall Frame
30 [1 1/8"] 135 [5 3/8"]
25[1"]
Drainage through
baffle
53.9 [2 1/8"] 36.5 [1 3/8"] 62 [2 1/2"]
152.4 [6"]
147[53/4"]
58.9 [2 3/8"] 36.6 [1 1/2"] 56.9 [2 1/4"]
215 [8 1/2"] 26.4 [1"]
Line of Slab Covers
Line of Vertical Fins
Aluminum Angle 50X50
Aluminum Angle 50X50
Mineral Wool Insulation
Concrete Anchors M10X95 Spacing TBD
Waterproofing Membrane
34.7[13/8"]
Drainage hole:
6x25mm @ 2' o.c.
Project IDDATE 59380
DRAWING NUMBER
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
VERSION DATE DESCRIPTION
CHECKED by ETEM
00
250 5th Ave Hotel - New York
PROJECT TITLE
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
KEY PLAN
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
DT - 110
Type K - Section Detail
29 Apr 2018 Issued For Approval
REFERENCE DRAWINGS
TpK - GA01
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
Etem Window Wall System E86
01
21 Sept 2018
01 Issued For Approval21 Sept 2018
5. 1396.6[4'-631/32"]836.4[2'-815/16"]3326[10'-1015/16"]
2718.2 [8'-11 1/32"]2693.2 [8'-10 1/32"]
494[1'-77/16"]
2359[7'-87/8"]
791.5 [2'-7 5/32"]
206 [8 1/8"]
252.1
[9 15/16"]
170 [6 11/16"]
206[81/8"]210
[89/32"]
3326[10'-1015/16"]
785[2'-629/32"]785[2'-629/32"]785[2'-629/32"]
00 Issued For Approval
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
REFERENCE DRAWINGS
KEY PLAN
SPECIFICATIONS
NOTES
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
28 Street
5thAvenue
A-102.02/A-200.01/A-301.01/A-303.01
A-506.01/A-630.01/A-635.00
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
08 Aug 2018
F
11[1/2"]
19[3/4"]6[1/4"]5[1/8"]
2[1/8"]
11[1/2"]
19[3/4"]6[1/4"]5[1/8"]
2[1/8"]
91[35/8"]
82[31/4"]toGridLineF
50 [2"]
91[35/8"]
50 [2"]
6 [1/4"]
8 [3/8"]
72 [2 7/8"]5 [1/4"]50 [2"]21 [7/8"]
75[3"]
52 [2"]93 [3 5/8"]
Door FrameDoor SashGlazing Bead
Glazing Glazing
301[11 7
8''] to Grid Line 3
Pressure Plate and Mullion Cap
110[43/8"]
Mullion
15[5/8"]
Transom Projection
1830 [6'] Clear Opening
Project IDDATE 59380
DT - 308
DRAWING NUMBER
ST03-Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 Issued For Approval
250 5th Ave Hotel - New York
PROJECT TITLE
ARCHITECT
PROVIDER
SERVICES
REFERENCE DRAWINGS
KEY PLAN
SUBCONTRACTOR
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/1'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
GA - 304
08 Aug 2018
08 Aug 2018
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
3
F
11[1/2"]
19[3/4"]6[1/4"]5[1/8"]
2[1/8"]
50 [2"]
15[5/8"]
50 [2"] 25 [1"]
110[43/8"]
114[41/2"]
82[31/4"]toGridLineF
Mullion
Gasket
Transom Projection
1 [0"]
Mineral Wool Insulation
21 [7/8"]
Rubber Joint
Pressure Plate and Mullion Cap
Glazing
60[23/8"]40[15/8"]
20x40x2mm
Aluminum L
Shaped
40x20x2 mm Aluminum Tube
60x20x2 mm Aluminum Tube
Interior Finishes
by Others
Steel Studs by Others
2693.2 [8'-10''] Frame Opening
26 [1"] to Grid Line 3
PVC Spacen
12 [1/2"]
130 [5 1/8"]
50[2"]
50[2"]
90 [3 1/2"]
95 [3 3/4"]
5 [1/4"] 2 [1/8"]
12 [1/2"]
Mullion
Baker Rod & Sealant
GlazingTransom Projection
441.4[1'-53
8'']toGridLineF
Pressure Plate and Mullion Cap
3381.2 [11' - 1 1
8''] to Grid Line 3
Aluminum Spigot
(part of bottom curtain wall bracket)
10mm Aluminum Plate
Bracket Below
10[3/8"]
Baker Rod & SealantPVC Spacen
3367.1[11'-09
16'']RoughOpening
PVC Spacen
Project IDDATE 59380
DT - 310
DRAWING NUMBER
ST03-Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 Issued For Approval
250 5th Ave Hotel - New York
PROJECT TITLE
OWNER
CONTRACTOR
ARCHITECT
PROVIDER
SERVICES
KEY PLAN
SUBCONTRACTOR
Ε Μ P I R E
M A N A G E M E N T
The
RINALDI
G R O U PGENERAL
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/1'' = 1'' @ ARCH C (24'' x18'')
28 Street
5thAvenue
GA-304
REFERENCE DRAWINGS
SPECIFICATIONS
NOTES
GL-1: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Glass
GL-1A: Overall 1 7/16", 1/4" Clear Tempered SN 60
+3/4" Argon Air Space+3/16"-0.06PVB-3/16" Clear
Laminated Tempered Glass
GL-2: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Glass
GL-2A: Overall 1 7/16", 1/4" Clear Tempered SN 60
Ceramic Coated +3/4" Argon Air Space
+3/16"-0.06PVB-3/16" Clear Laminated Tempered
Glass
GLASS TYPES:
-Glazing Specifications as per Section 08 00 00
-Curtain Wall Specifications as per Section 08 44 13
Thermally Broken Aluminum Curtain Wall System,
Powder Coating Finish
-Aluminum Doors Specifications as per
Section 08 41 13
Thermally Broken Aluminum Opening Doors System,
Powder Coating Finish
Etem Doors System E75
Etem Curtain Wall System E85
-Steel Framing, Parapet and Slab Edges Defined
according to Structural Drawings
-Primary units in mm
08 Aug 2018
08 Aug 2018
6. 22018 – present
Assignment of:
-Shop Drawings
-Fabrication Drawings
-Installation Drawings
Scope of work:
-Aluminum Curtain Walls
-Aluminum Doors & Windows
-Aluminum Slab Covers
-Aluminum Fins
68 - 70
SPRING
STREET
New York, USA
7. 2392.9[7'-101/4"]2382.1[7'-93/4"]1255.7[4'-13/8"]
FO6030.6[19'-93/8"]
55.8[21/4"]
(Sill)
574.7 [1'-10 5/8"]574.7 [1'-10 5/8"]
558.8[1'-10"]
D E
1291.4 [4'-2 7/8"]
5832.5 [19'-1 5/8"]
609.6[2']
T.O.F. 3rd FL
28' - 00"
6096[20'](8''tilesx30)609.6[2']609.6[2']
D.1
609.6[2']
609.6[2']
30' - 00"
50' - 00"
RO6151.6[20'-21/8"]
ROfromSteelStudtoSteelStud
UnitsA,B
L.O. SteelStud
50' - 02"
FO 2328.1 [7'-7 5/8"]
TO 2346.3 [7'-8 3/8"]
R.O.=2352.6 [7'-8 5/8"]
FO 1158.9 [3'-9 5/8"]
TO 1177.9 [3'-10 3/8"]
RO 1184.2 [3'-10 5/8"]
From Steel Stud to Steel Stud
FO 1158.9 [3'-9 5/8"]
TO 1177.9 [3'-10 3/8"]
RO 1184.2 [3'-10 5/8"]
From Steel Stud to Steel Stud
2432.1[7'-113/4"]1155.7[3'-91/2"]2498.7[8'-23/8"]614.4[2'-01/8"]
50[2"]1775.6[5'-97/8"]50[2"]506.5[1'-8"]50[2"]1155.7[3'-91/2"]50[2"]1786.3[5'-103/8"]50[2"]506.5[1'-8"]
50[2"]
55.8[21/4"]
208[81/4"]
T.O.F. 3rd FL
28' - 00"
T.O.F. 4th FL
40' - 00"
T.O.F. 5th FL
52' - 00"
406.4[1'-4"]
26.8 [1"]
406.4[1'-4"]614.4[2'-01/8"]
55.8[21/4"]
406.4[1'-4"]
165.1 [6 1/2"]
125.2 [4 7/8"]
UNITS A - B ELEVATION UNITS A - B SECTION
FO 3481.6 [11'-5 1/8"]
RO 3505.2 [11'-6"]
T.O.F. 2nd FL
16' - 00"
T.O.F. 1st FL
0' - 00"
979.1 [3'-2 1/2"]
200 [7 7/8"]
873.4 [2'-10 3/8"]
200 [7 7/8"]
979.1 [3'-2 1/2"]
2360[7'-87/8"]1294.4[4'-3"]2997.8[9'-10"]
DCB
127.8 [5"]127.8 [5"]
1244.5[4'-1"]
D.1A.9
FO7896.7[25'-107/8"]
RO7916.9[25'-113/4"]
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
T.O.F. 2nd FL
16' - 00"
T.O.F. 1st FL
0' - 00"
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
T.O.F. 2nd fl
15' - 10"
T.O.S. 1st FL
-0' - 02"
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
2028.4 [6'-7 7/8"]
Project IDDATE 23 May 2018 68SPR
106
DRAWING NUMBER
North Partial Elevation and Section
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/16'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Section 106 -2 Scale as notedElevation 106 -1 Scale as noted Section 106 -3 Scale as noted
200 [7 7/8"]
979.1 [3'-2 1/2"]
2360[7'-87/8"]1294.4[4'-3"]2997.8[9'-10"]
D
127.8 [5"]
1244.5[4'-1"]
D.1
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
T.O.F. 2nd FL
16' - 00"
T.O.F. 1st FL
0' - 00"
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
T.O.F. 2nd fl
15' - 10"
T.O.S. 1st FL
-0' - 02"
Maxtorque
(Nm)50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
7896.7[25'-107/8"]
7916.9[25'-113/4"]
75[3"]
50[2"]1650.7[5'-5"]
50[2"]
534.3[1'-9"]
50[2"]
1194.4[3'-11"]
50[2"]
1194.5[3'-11"]
50[2"]2997.8[9'-10"]
614.4[2'-01/4"]
1
369.1 [1'-2 1/2"] 290 [11 3/8"]
659.1 [2'-2"]
2028.4 [6'-7 7/8"]
Project IDDATE 23 May 2018 68SPR
106
DRAWING NUMBER
North Partial Elevation and Section
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1/16'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Section 106 -2 Scale as notedElevation 106 -1 Scale as noted Section 106 -3 Scale as noted
Maxtorque
(Nm)50
Max torque
(Nm) 50
50 [2"]
Aluminum Mullion
Aluminum Angle
40 x 40 x 2
20 [3/4"]
88[31/2"]
50 [2"]
11.8 [1/2"]
Pressure Plate
Aluminum Cap
120 x 20 x 2
55 [2 1/8"] 14.2 [1/2"]
68.3 [2 3/4"]
20 [3/4"]
93.7[33/4"]
28[11/8"]
128.9[51/8"]
Projected
Window
Sash
Terra cotta
by Others
Interior Finishes
By Others
Seal on Backer Rod
Waterproofing
Membrane
SF1 F.D. 13'-4 1/8''
11.8 [1/2"]
SF2 F.D. 11'-5 1/8''
SF1 R.O. 13'-5''
SF2 R.O. 11'-6''
Max torque
(Nm) 50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
200 [7 7/8"]
20 [3/4"]50 [2"]20 [3/4"]
55 [2 1/8"]55 [2 1/8"]
88[31/2"]
30[11/8"]88[31/2"]
40.3 [1 5/8"]
68.3 [2 3/4"]
200 [7 7/8"]
77[3"]
87[33/8"]63[21/2"]28[11/8"]
130[51/8"]25.4[1"]
Aluminum Mullion
Pressure Plate
Aluminum Cap
120 x 20 x 2
Projected
Window
Sash
100 x 20 x 2
Project IDDATE 23 May 2018 68SPR
110
DRAWING NUMBER
North Plan Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Detail 110 - 2
Scale as noted
Detail 110 - 2
Scale as noted2nd Floor SF1 Ref. Shildan 5.3, 5.2, 5.1
E85104
2
1
50 [2"]
20 [3/4"]8 [3/8"]40.4 [1 5/8"]20 [3/4"] 8 [3/8"] 40.4 [1 5/8"]
56[21/4"]37.8[11/2"]
56[21/4"]37.8[11/2"]77[3"]166.7[61/2"]
25.9[1"]toGridLine1
14.2 [1/2"] 50 [2"] 14.2 [1/2"]
1460.5 [4'-9 1/2"] to Grid Line D1
Aluminum Mullion
Aluminum Cap
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Line of Mullions and Transcents Edge
1
77[3"]56[21/4"]37.8[11/2"]166.7[61/2"]
28[11/8"]
50 [2"]12.7 [1/2"] 68.4 [2 3/4"]
25.9[1"]toGridLine1
1456 [4'-9 3/8"] to Grid Line D1
R.O.=1184 [3'-10 5/8"] (Type A,A1,C)
F.D.=1159 [3'-9 5/8"]
337.4[1'-11/4"]
Aluminum Mullion
Aluminum Mullion
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Terracota Cladding by others
Interior Walls by others
Line of Mullions and Transcents Edge
Pressure Plate
Cap
9.6 [3/8"]
3' - 9 15/16"
Seal on Backer Rod
Detail 103 -1
scale as noted
Detail 103 -2
scale as noted
Project IDDATE 23 May 2018 68SPR
103
DRAWING NUMBER
North Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Ref. Shildan 5.4, 5.5, 5.6
E85104
2
1
50 [2"]
20 [3/4"]8 [3/8"]40.4 [1 5/8"]20 [3/4"] 8 [3/8"] 40.4 [1 5/8"]
56[21/4"]37.8[11/2"]
56[21/4"]37.8[11/2"]77[3"]166.7[61/2"]
25.9[1"]toGridLine1
14.2 [1/2"] 50 [2"] 14.2 [1/2"]
1460.5 [4'-9 1/2"] to Grid Line D1
Aluminum Mullion
Aluminum Cap
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Line of Mullions and Transcents Edge
1
77[3"]56[21/4"]37.8[11/2"]166.7[61/2"]
28[11/8"]
50 [2"]12.7 [1/2"] 68.4 [2 3/4"]
25.9[1"]toGridLine1
1456 [4'-9 3/8"] to Grid Line D1
R.O.=1184 [3'-10 5/8"] (Type A,A1,C)
F.D.=1159 [3'-9 5/8"]
337.4[1'-11/4"]
Aluminum Mullion
Aluminum Mullion
Window Sash
Glass
Gasket
Window Frame
Slab Edge (3rd & 5th floor)
Slab Edge (4th & 6th floor)
Terracota Cladding by others
Interior Walls by others
Line of Mullions and Transcents Edge
Pressure Plate
Cap
9.6 [3/8"]
3' - 9 15/16"
Seal on Backer Rod
Detail 103 -1
scale as noted
Detail 103 -2
scale as noted
Project IDDATE 23 May 2018 68SPR
103
DRAWING NUMBER
North Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Ref. Shildan 5.4, 5.5, 5.6
Aluminum Mullion
Window Sash
Window Frame
Aluminum Cap
Glass
Slab Edge of 4th & 6th fl.
Slab Edge of 3th & 5th fl.
50 [2"]
20.4 [3/4"] 53 [2 1/8"]20.4 [3/4"]73.4 [2 7/8"]
95.5[33/4"]166[61/2"]75.5[3"]
31.5[11/4"]
67.5[25/8"]
188.8 [7 3/8"]
50 [2"]69.4 [2 3/4"] 69.4 [2 3/4"]
95.5[33/4"]166[61/2"]
35.5[13/8"]8[3/8"]
50 [2"]
20.4 [3/4"] 53 [2 1/8"]
50 [2"] 69.4 [2 3/4"]
25.9[1"]toGridLine1
1
75.5[3"]
32[11/4"]
R.O.=1184 [3'-10 5/8"] (Type A,A1,C)
F.D.=1159 [3'-9 5/8"]
1456 [4'-9 3/8"] to Grid Line D1
Aluminum Mullion
Window Sash
Window Frame
Aluminum Mullion
Glass
Slab Edge of 4th & 6th fl.
Slab Edge of 3th & 5th fl.
12.7 [1/2"]
Pressure Plate
Cap
Concealed sash
window frame
Interior Finishes
By Others
Terra cotta
by Others
9.6 [3/8"]
3' - 9 15/16"
Seal on Backer Rod
Detail 102 - 1
scale as noted
32[11/4"]
Detail 102 - 2
scale as noted
Project IDDATE 23 May 2018 68SPR
102
DRAWING NUMBER
North Plan Detail
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Ref. Shildan 5.4, 5.5, 5.6
556.5[1'-97/8"]
50[2"]
14.3[1/2"]
68.4[23/4"]
Custom
Wind Load bearing Bracket
55.8[21/4"]
60.3[23/8"]
101.6 [4"]
346.1[1'-15/8"]
165.1 [6 1/2"]
123.2 [4 7/8"]
63.4 [2 1/2"]
Mineral
Wool
50 x 50 x 3
Aluminum cap
Aluminum transom
1
63.4 [2 1/2"]
M10 Bolt Set
406.4[1'-4"]
T.O. SteelStud
30' - 00"
110.6[43/8"]
Waterproof Membrane
660.4[2'-02'']
toSlab
TERRACOTAFACEPROJECTION
Maxtorque
(Nm)50
Maxtorque
(Nm)50
T.O.F. 4th FL
40' - 00"
M12 x 140
concrete anchor
120[43/4"]
Custom
Dead Load
bearing Bracket
53[21/8"]
73.4[27/8"]
75.5 [3"]
69.4[23/4"]50[2"]
140 [5 1/2"]26 [1"]
1
4th Fl.
T.O.S. 4th FL
39' - 10"
368.3 [1'-2 1/2"]
312 [1'-0 1/4"]
38' - 08"
138.2[51/2"]
TERRACOTAFACEPROJECTION
556.5[1'-97/8"]
73.4[27/8"]
68.4[23/4"]
50[2"]69.4[23/4"]14.3[1/2"]
9[3/8"]
127 [5"]26 [1"]
Projected window
sash
Concealed sash
window
1
RO6146.8[20'-02'']
ROfromSteelStudtoSteelStud
UnitsA,B
Detail 105 -1
Scale as noted
Detail 105 -2
Scale as noted
Detail 105 -2
Scale as noted
Project IDDATE 23 May 2018 68SP
105
DRAWING NUMBER
North Section Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSIO
00
VERSION DATE DESCRIPTION
CHECKED by ETE
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 2'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Sill Detail A-B Ref. Shildan 5.15
556.5[1'-97/8"]
50[2"]
14.3[1/2"]
68.4[23/4"]
Custom
Wind Load bearing Bracket
55.8[21/4"]
60.3[23/8"]
101.6 [4"]
346.1[1'-15/8"]
165.1 [6 1/2"]
123.2 [4 7/8"]
63.4 [2 1/2"]
Mineral
Wool
50 x 50 x 3
Aluminum cap
Aluminum transom
1
63.4 [2 1/2"]
M10 Bolt Set
406.4[1'-4"]
T.O. SteelStud
30' - 00"
110.6[43/8"]
Waterproof Membrane
660.4[2'-02'']
toSlab
TERRACOTAFACEPROJECTION
Maxtorque
(Nm)50
Maxtorque
(Nm)50
T.O.F. 4th FL
40' - 00"
M12 x 140
concrete anchor
120[43/4"]
Custom
Dead Load
bearing Bracket
53[21/8"]
73.4[27/8"]
75.5 [3"]
69.4[23/4"]50[2"]
140 [5 1/2"]26 [1"]
1
4th Fl.
T.O.S. 4th FL
39' - 10"
368.3 [1'-2 1/2"]
312 [1'-0 1/4"]
38' - 08"
138.2[51/2"]
TERRACOTAFACEPROJECTION
556.5[1'-97/8"]
73.4[27/8"]
68.4[23/4"]
50[2"]69.4[23/4"]14.3[1/2"]
9[3/8"]
127 [5"]26 [1"]
Projected window
sash
Concealed sash
window
1
RO6146.8[20'-02'']
ROfromSteelStudtoSteelStud
UnitsA,B
Detail 105 -1
Scale as noted
Detail 105 -2
Scale as noted
Detail 105 -2
Scale as noted
Project IDDATE 23 May 2018 68SP
105
DRAWING NUMBER
North Section Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSI
00
VERSION DATE DESCRIPTION
CHECKED by ETE
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 2'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Sill Detail A-B Ref. Shildan 5.15
50[2"]
26 [1"]
166 [6 1/2"]
241.5 [9 1/2"]
32 [1 1/4"]
96.5 [3 3/4"]
9.6[3/8"]
69.4[23/4"]
73.4[27/8"]
1
Custom
Wind Load bearing Bracket
M10 Bolt Set
transom
Window frame
Concealed sash
window
Aluminum cap
Pressure plate
5th Fl.
L.O. SteelStud
50' - 02"
50' - 08"
Structural Framing by GC
for windows attachments and TC
(TYP)
Structural Framing by GC
for windows attachments and TC
(TYP)
50' - 00"
55.6[21/4"]
RO6146.8[20'-02'']
ROfromSteelStudtoSteelStud
UnitsA,B
312 [1'-0 1/4"]
203.2 [8"]
TERRACOTAFACEPROJECTION
Detail 104 -1
Scale as noted
Head Detail A-B Ref. Shildan 5.14
Maxtorque
(Nm)50
Max torque
(Nm) 50
50 [2"]
Aluminum Mullion
Aluminum Angle
40 x 40 x 2
20 [3/4"]
88[31/2"]
50 [2"]
11.8 [1/2"]
Pressure Plate
Aluminum Cap
120 x 20 x 2
55 [2 1/8"] 14.2 [1/2"]
68.3 [2 3/4"]
20 [3/4"]
93.7[33/4"]
28[11/8"]
128.9[51/8"]
Projected
Window
Sash
Terra cotta
by Others
Interior Finishes
By Others
Seal on Backer Rod
Waterproofing
Membrane
SF1 F.D. 13'-4 1/8''
11.8 [1/2"]
SF2 F.D. 11'-5 1/8''
SF1 R.O. 13'-5''
SF2 R.O. 11'-6''
Max torque
(Nm) 50
Maxtorque
(Nm)50
Maxtorque
(Nm)50
200 [7 7/8"]
20 [3/4"]50 [2"]20 [3/4"]
55 [2 1/8"]55 [2 1/8"]
88[31/2"]
30[11/8"]88[31/2"]
40.3 [1 5/8"]
68.3 [2 3/4"]
200 [7 7/8"]
77[3"]
87[33/8"]63[21/2"]28[11/8"]
130[51/8"]25.4[1"]
Aluminum Mullion
Pressure Plate
Aluminum Cap
120 x 20 x 2
Projected
Window
Sash
100 x 20 x 2
Project IDDATE 23 May 2018 68SPR
110
DRAWING NUMBER
North Plan Details
DRAWING TITLE
DRAWN by Skyline Facades
VERSION
00
VERSION DATE DESCRIPTION
CHECKED by ETEM
00 23 May 2018 Issued For Approval
68 - 70 Spring Street
PROJECT TITLE
DEVELOPER
ARCHITECT
PROVIDER
SERVICES
SUBCONTRACTOR
DJL Limited
Development
FACADE
SYSTEM
ENGINEERING
FACADE
SCALE 1'' = 1'' @ ARCH D (36'' x 24'')
BIALOSKY
New York
Detail 110 - 2
Scale as noted
Detail 110 - 2
Scale as noted2nd Floor SF1 Ref. Shildan 5.3, 5.2, 5.1
8. 32012-2013
Assignment of:
-New Aluminum Cladding System
development (W-1016)
-Tender Stage Estimation
-Shop Drawings
-Bill of Materials
-Fabrication Drawings
-Installation Drawings
Scope of work:
-Aluminum Composite Panels Cladding
-Decorative Aluminum Screen Walls
-Suspended Metal Ceilings
TORONTO
PREMIUM
OUTLET
Toronto, Canada
9. M10 connection Parts ---->
5mm thick ------->
PR
M10 connection parts
M10 safety nuts
L angle L-10(47-90mm)
Lower part
of gallery joist
(by others)
M10 Channel nuts
CSN4141
washer
M10 Channel nuts
CN4141
L-18B
(5mm thick)
Upper part
of gallery joist
(by others)
L-02
(5mm thick)
L-01
(5mm thick)
M10 connection parts
long
Lower part
of gallery joist
(by others)
Upper part
of gallery joist
(by others)
PR
Pair rods for
indirect suspension
of basic part
P4141
detail 6
804.67 64
detail 6b
PR (P4141E)
Pair rods
Under Gallery parts
Length
(mm)Code Qnty
(pcs)
-L-10 64
M10 connection Parts ---->
5mm thick ------->
PR
M10 connection parts
M10 safety nuts
L angle L-10(47-90mm)
Lower part
of gallery joist
(by others)
M10 Channel nuts
CSN4141
washer
M10 Channel nuts
CN4141
L-18B
(5mm thick)
Upper part
of gallery joist
(by others)
L-02
(5mm thick)
L-01
(5mm thick)
M10 connection parts
long
Lower part
of gallery joist
(by others)
Upper part
of gallery joist
(by others)
PR
Pair rods for
indirect suspension
of basic part
P4141
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
detail 6
804.67 64
Scale:
Project No: 1203 Td
1 : 8
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No: Susp_partUGal
Pair rods under gallery joist
detail 6b
All dimensions added by Elegant Facade
are in mm.
PR (P4141E)
Pair rods
Under Gallery parts
Length
(mm)Code Qnty
(pcs)
-L-10 64
-M10 channel nuts CSN4141
M10 channel nuts CN4141
-
64
M10 connection part 64
M10 safety nuts
256
512
Washer 448
L-18 64
Plate L-01 64
Plate L-02 64
M10 connection part(long) 128
-
-
-
-
-
-
-
Detail 5b
Detail 5a
Detail 5a
M10 Channel nuts
CSN4141
Angle L-09B
M10 connection
parts
substructure rod
P4141x2(41x82mm)
suspension rod
P4141(41x41mm)
substructure rod
P4141x2(41x82mm)
suspension rod
P4141(41x41mm)
M10 Channel nuts
CSN4141
M10
safety nuts
Washer
M10 Channel nuts
CN4141
M10 connection
parts
Angle L-09B
Angle L-18B
Details 5a - 5b Exploded Detail 5a
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES: Project No:1203 Td
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No:SubSusp_Det-5
Substructure between
Scale: 1 : 25
parts -suspension detail
suspension rod
P4141(41x41mm)
substructure rod
P4141x2(41x82mm)
Angle L-09B
M10 connection part
M10 Channel nuts
CSN4141
M10 Channel nuts
CN4141
M10 safety nuts
washer
M10
Channel nuts
CN4141
Angle L-13E
Perforated panel
Exploded Detail 1
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
Scale:
Project No:1203 Td
1 : 25
Revision A:
Revision B:
Detail ID:
Part No:Sub_Det-1
RCP substructure detail (corner)All dimensions added by
Elegant Facade are in mm.
substructure rod
P4141x2(41x82mm)
suspension rod
P4141(41x41mm)
Angle L-13E
M10 Channel nuts
CSN4141
Angle L-09B
Exploded Detail 1b
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
Scale:
Project No:1203 Td
1 : 25
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No:Sub_Det-1b
RCP substructure detail(corner)All dimensions added by Elegant
Facade are in mm.
M10 Channel nuts
CSN4141
M10 Channel nuts
CN4141
M10 Channel
nuts CSN4141
M10
safety nuts
suspension rod
P4141(41x41mm)
L-09B
substructure rod
P4141x2(41x82mm)
substructure rod
P4141x2(41x82mm)
Angle L-18B
Angle L-09B
Angle L-18B
Plate L-02A
system used:
PROJECT:
ELEGANT FACADE INC. ARCHITECTURAL SOLUTIONS
NOTES:
Scale:
Project No: 1203 Td
1 : 18 , 1:14
Revision A:
Design Date:
Revision B:
02 MAY 2013
Detail ID:
Part No: Sr_A-B-C-D
Suspension rods parts details
All dimensions added by Elegant Facade
are in mm.
2040 9Sr-A(P4141 41x41mm)
part A
Suspension rods &
componets
Length
(mm)Code Qnty
(pcs)
2588
1735 12Sr-B(P4141 41x41mm)
part B
Sr-D(P4141 41x41mm)
part D
92040
3588
Sr-C (P4141 41x41mm)
part C
1278 27
662.7 3
L-09B(partA) 66
M10 channel nuts CSN4141 130
M10 safety nuts
Washer 132
M10 connection parts
M10 channel nuts CN4141 66
68
- -
-
-
-
-
-
-
132
L-02A 2-
Weather Barrier
Tyvec HomeWrap
Seathing
PreDrilled E-16150
ST 4,2 (No 10)
Length 30mm
Fix PreDrilled E-16150 perimetrically at
the under edge of the canopy, usind No
10 Selfdrilling screws
PreDrilled E-16900
Fix PreDrilled E-16900 at the middle,
usind No 10 Selfdrilling screws
Canopy Edge
INDICATIVE APPLY
Elegant Façade Inc.
Architectural Solutions
Alumicore
WS 1016
1203 GD-10
Generic Drawings For
PROJECT 1203 (TPO)
Alumicore ACP
Slide the ACP panel into the grooves.
Canopy Edge
INDICATIVE APPLY
Elegant Façade Inc.
Architectural Solutions
Alumicore
WS 1016
1203 GD-16
Generic Drawings For
PROJECT 1203 (TPO)
BETWEEN TWO TYPICAL BRACKETS (EVERY 5ft) WE PLACE 5 PLATE
HOLDERS (EVERY 1ft) STARTING 1/2 ft FROM THE EDGE.
1ft
1ft
1ft
1ft
1
2
ft
1
2
ft
1ft
1
2
ft
5ft
1
2
ft
6
6.1 6.2
1213.4 [3'-11 3/4"] 1213.4 [3'-11 3/4"] 1214.2 [3'-11 3/4"] 1212.9 [3'-11 3/4"]
63.1 [2 1/2"]
to Grid Line 6.1
3048.8 [10']
914.6 [3']
101.6 [4"]
101.6 [4"]
914.6 [3']
2082.3[6'-10"]
1778[5'-10"]
2082.3[6'-10"]
1778[5'-10"]
456.8[1'-6"]
50[2"]
100' - 0'' T/O FIN. FLOOR
117' - 6'' T/O FRAMING
5333.7[17'-6"]
S.3
S.1
1213.4 [3'-11 3/4"] 1213.4 [3'-11 3/4"] 1214.2 [3'-11 3/4"] 1212.9 [3'-11 3/4"]
63.1 [2 1/2"]
to Grid Line 6.1
2205.2 [7'-2 7/8"] to Grid Line 6.2
743[2'-51/4"]
toGridLineS.1
304.8[1']
6 6.1 6.2
03
GA-02
sim PD-06
S.1
124' - 0'' T/O STEEL BEAM
203.2[8"]
S.3
117' - 6'' T/O FRAMING
110' - 9'' U/S STEEL
100' - 0'' T/O FIN. FLOOR
203.2[8"]583.9[1'-11"]
304.8 [1']
sim SD-19
508[1'-8"]506.9[1'-8"]509.9[1'-81/8"]508[1'-8"]279[11"]
2082.6[6'-10"]
743 [2'-5 1/4"]
to Grid Line S.1
3251.4[10'-8"]
02. Floorplan
1/30
03. Section
1/16
01. ELevation
1/30
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 11 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B12-GA02
Partial South Elevation - Section
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
as Noted @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
A12-01, A12-01A, A12-03, A12-04, A12-09
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
10. 42018
Assignment of:
-New Aluminum Cladding System
development (W-1415)
-Tender Stage Estimation
-Shop Drawings
-Bill of Materials
-Fabrication Drawings
-Installation Drawings
Scope of Work:
-Aluminum Composite Panels Cladding
-Brick Cladding
-Fiber Cement Board Cladding
-Decorative Aluminum Screen Walls
TORONTO PREMIUM OUTLET_
EXPANSION
Toronto, Canada
11. U.1T.9T.5
124' - 4'' T/O PARAPET
122' - 4'' T/O PARAPET
137' - 0'' T/O PARAPET
T
1158.3 [3'-9 5/8"]1219.2 [4']1219.2 [4']1219.2 [4']605.5 [1'-11 7/8"]
709.8[2'-4"]
6637.9[21'-93/8"]
S.10
1219.2 [4'] 1219.2 [4'] 1219.2 [4'] 1219.2 [4']
303.4[1']
4876.8 [16']
02
GA-07
431.4[1'-5"]
864.4[2'-10"]
253.2[10"]
864.4[2'-10"]
2438.4[8']
764 [2'-6 1/8"] 384.3 [1'-3 1/8"]
1201.9 [3'-11 3/8"]
108.4[41/4"]
303.4[1']
80.3[31/8"]
520.2[1'-81/2"]
456.7[1'-6"]
4217 [13'-10"]
5283.2 [17'-4"]
92.6[35/8"]
103[4"]
10.6[3/8"]
1224.6 [4']1224.6 [4'] 690.6 [2'-3"]690.6 [2'-3"]
1224.6 [4']1224.6 [4'] 690.6 [2'-3"]690.6 [2'-3"]
1040.9[3'-5"]
100' - 0'' F.FL.
1322.2[4'-4"]
MP2 MP2MP2MP2
MP2MP2
MP1MP1
CL1
CL1CL1
MP2MP2
B1
B1
S1
S1
02
GA-07
01
GA-07
11.10
11.8
T.9T.5
S.10 T
U.1
307.8[1'-01/8"]
709.8 [2'-4"] 336.1 [1'-1 1/4"]
1219.2[4']413.5[1'-41/4"]
788.4 [2'-7"] 413.5 [1'-4 1/4"]
1201.9 [3'-11 3/8"]
357.6[1'-21/8"]
toGridLine11.10
535.1 [1'-9 1/8"]
to Grid Line U.1
666.8 [2'-2 1/4"]
to Grid Line U.1
509.4[1'-8"]
sim PD-02
761.3 [2'-6"]
to Grid Line S.10
609.6 [2']
to Grid Line T
422.3[1'-45/8"]
toGridLine11.8
1330.3 [4'-4 3/8"]
720.7 [2'-4 3/8"]
to Grid Line T
3159.1 [10'-4 3/8"] to Grid Line T 1338.4 [4'-4 3/4"]
4497.5 [14'-9 1/8"] to Grid Line T
934.7 [3'-0 3/4"]
933
[3
'-0
3/4
"]
138.6[51/2"]
toGridLine11.10
sim PD-07 sim PD-07
sim PD-07
175.6[67/8"]
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 11 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B12-GA06
Partial East Elevation
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/30 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
A12-01, A12-01B, A12-03, A12-05, A12-06, A12-10
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
02. Floor plan
1/30 20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches o
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
Q.12 Q.10
125' - 8'' T/O PARAPET
2438.4[8']
1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"]
1219.3 [4'] 1219.3 [4'] 1219.3 [4'] 1219.3 [4'] 1303.7 [4'-3 3/8"]1219.3 [4']1219.3 [4']1219.3 [4']1305.7 [4'-3 3/8"]
03
GA-06
03
GA-06
03
GA-07
819[2'-81/4"]964.2[3'-2"]963.5[3'-2"]963.5[3'-2"]963.5[3'-2"]951.9[3'-11/2"]
1219.3 [4']
9250.7 [30'-4 1/4"]
101.6[4"]
2183.7[7'-2"]
101.6[4"]
2183.7[7'-2"]
03
GA-07
MP2
MP2MP2 MP4
1219.3 [4']1219.3 [4']1219.3 [4']1219.3 [4']1219.3 [4']967.6 [3'-2 1/8"] 967.7 [3'-2 1/8"]
1727.2[5'-8"]914.7[3']
MP2
1727.2[5'-8"]914.7[3']
MP2
7250 [23'-9 3/8"]
4Q
5Q
1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"] 1200 [3'-11 1/4"]
305.6[1']
50[2"]
03
GA-07
03
GA-07
03
GA-06
03
GA-06
251.4[97/8"]
204.7[8"]
776.1 [2'-6 1/2"]
251.6
[9
7/8"]
697.5
[2
'-3
1/2"]
204.7
[8
"]
204.7
[8
"]
254.4
[1
0"]
697.5
[2
'-3
1/2"]
776.1 [2'-6 1/2"]
251.4[97/8"]
204.7[8"]
125' - 8'' T/O PARAPET
4Q
125' - 6'' T/O STEEL
117' - 6'' U/S DECK
112' - 0'' U/S OF CANOPY
109' - 0'' T/O GLAZING
110' - 3/8'' U/S STEEL
100' - 0'' T/O FIN. FLOOR
5Q
571.7[1'-101/2"]571.7[1'-101/2"]574.7[1'-105/8"]568.7[1'-103/8"]
358.6 [1'-2 1/8"]
355.6 [1'-2"]
305.6 [1']
2438.4[8']4329.4[14'-21/2"]
6717[22'-01/2"]
MP2
DATE 08 Jun 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
08 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B10-GA7
North West Elevation & Plan-Section
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
as noted @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
10
00
03. Section 1/1602. Plan 1/30
A10-01, A10-01A, A10-03, A10-04, A10-08
18 Jun 2018 Issued For Approval01
125' - 8'' T/O PARAPET
4Q
125' - 6'' T/O STEEL
117' - 6'' U/S DECK
112' - 0'' U/S OF CANOPY
109' - 0'' T/O GLAZING
110' - 3/8'' U/S STEEL
100' - 0'' T/O FIN. FLOOR
5Q
571.7[1'-101/2"]571.7[1'-101/2"]574.7[1'-105/8"]568.7[1'-103/8"]
358.6 [1'-2 1/8"]
355.6 [1'-2"]
305.6 [1']
2438.4[8']4329.4[14'-21/2"]
6717[22'-01/2"]
MP2
DATE 08 Jun 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
08 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B10-GA7
North West Elevation & Plan-Section
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
as noted @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
10
00
03. Section 1/16
A10-01, A10-01A, A10-03, A10-04, A10-08
18 Jun 2018 Issued For Approval01
1219.2 [4']1219.6 [4'] 1219.2 [4'] 1102 [3'-7 3/8"]726.4 [2'-4 5/8"]
417.6 [1'-4 1/2"]
31.133.134
132' - 0'' T/O PARAPET
01
GA-10
4368.8[14'-4"]
5486.4 [18']
6014.7 [19'-8 3/4"]
1324[4'-41/8"]
101.6[4"]
282.4 [11 1/8"]3226.3 [10'-7"]
1330.2[4'-43/8"]
1219.2 [4']1219.6 [4'] 1219.2 [4'] 1102 [3'-7 3/8"]726.4 [2'-4 5/8"]
990.6 [3'-3"]
1219.2 [4'] 1219.2 [4'] 1219.2 [4']
1366.5 [4'-5 3/4"]
31
1320.8[4'-4"]
1207 [3'-11 1/2"]
1219.2 [4']1219.2 [4']721.8 [2'-4 3/8"]
1219.6 [4']1219.6 [4']1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4'] 1219.6 [4']871.3 [2'-10 1/4"] 871.3 [2'-10 1/4"]
5080 [16'-8"]
TT.9
TT.8
TT.7
3707.6 [12'-2"]
305.5[1']
50[2"]
1205.5 [3'-11 1/2"]
262.8[103/8"]
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
00
VERSION DATE DESCRIPTION
Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B14-GA08
Partial North Elevation & Plan
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/30 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
10
00
05 Jul 2018
05 Jul 2018
A14-01A, A14-03, A14-04, A14-09, A14-10
14
01. ELevation
1/30
02. Floorplan
1/30
M10threadedRod
110 [4 3/8"]
150[57/8"]
80[31/8"]
50 [2"] 255.6 [10 1/8"] 50 [2"] 50.8 [2"]
9.8 [3/8"]
18.6 [3/4"] 152.4 [6"] 15.9 [5/8"]
3 [1/8"]
50.8 [2"]
50[2"]424.7[1'-43/4"]50[2"]
101.6[4"]50.8[2"]101.6[4"]50.8[2"]101.6[4"]50.8[2"]101.6[4"]25[1"]25[1"]
50 [2"]
50[2"]
3[1/8"]
42[15/8"]
42 [1 5/8"]
3 [1/8"]
50
[2
"]
70.7[23/4"]
35[13/8"]
100 [3 7/8"]
258.5[101/8"]
36
1
[1
'-2
1/
4"
]
45°
42 [1 5/8"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7982-C
ST6.3(No14)
DIN7982-C
ST6.3(No14)
DIN7982-C
2 Screws per Slat
M10 Bolt Set
35 x3mm (1 3
8'' x 1
8'')
Aluminum
plate pre-connected to slats
Wood blocks from steel stud to steel stud
designed, supplied and installed by others
Blocking and steel studs
to able to support
the following factored loads:
Vert.= 0.7 kN (downwards)
Hor.= 1.7 kN (inward or outward)
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
50x50x3
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
3mm aluminum plate
both sides
Aluminum slat
2''x4''x1/8''
Nut & 25mm Dia
Washer
50x110x3 SS Angles
min 38 mm
18
[3/4"]
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
SD-08
Section Detail (MP5 Screen)
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
Project ID 15124.03
REFERENCE DRAWINGS
01/B9-GA9
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
01 16 May 2018 Issued For Approval
50[2"]
3 [1/8"] 50 [2"] 305.6 [1']
50[2"]35[13/8"]386.5[1'-31/4"]50[2"]50[2"]35[13/8"]50[2"]50[2"]
571.5[1'-101/2"]
255.6 [10 1/8"] 50 [2"]
57.2 [2 1/4"]28.4 [1 1/8"]100.8 [4"]
200[77/8"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
M10 Bolt Set
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
50x50x3
50x110x3 SS Angles
3mm aluminum plate
both sides
Aluminum Tube
2"x2"x1/8"
3 layers 3/4" FR plywood fasten together
with 2 - #8 x 2" long wood screws at 12" oc
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
688.8 [2'-3 1/8"] to Grid Line UU.9
UU.9
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
100 [3 7/8"]
50 [2"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
50x50x3
3mm aluminum plate
both sides
Aluminum Tube
2"x2"x1/8"
50.8 [2"] 10 [3/8"]49.2 [1 7/8"]
M10 threaded rod w/
nut and 25mm Dia. washer
Steel Studs to be designed to support
the following factored load at anchor
locations
Vert. = 0.7 kN (Downwards)
Hor. = 1.7 (Inward or Outward)
Aluminum Holding Plate
20mm Dia.
6mm thick
Aluminum Holding Plate
20mm Dia.
6mm thick
(Identical to the one used in TPO phase 1)
(Identical to the one used in TPO phase 1)
(MP4)
3mm Perforated Aluminum Sheet
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 03 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
SD - 19
Section Detail
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/2 @ ARCH C (24'' x18'')
REFERENCE DRAWINGS
A13-01, A13-01C, A13-03, A13-04, A13-08
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic
Fire Rated, 4 mm total thickness (2 layers 0.5 mm
THK. Aluminum).
-All self drilling screws to penetrate min. 3 pitches
of thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
124' - 3'' T/O FRAMING
50 [2"]304.8 [1']152.4 [6"]
3 [1/8"]
457.2 [1'-6"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
M10 Bolt Set
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Aluminum angle
2"x6"x1/8"
50x110x3 SS Angles
3mm aluminum plate
both sides
Aluminum Tube
2"x6"x1/8"
3 layers 3/4" FR plywood fasten together
with 2 - #8 x 2" long wood screws at 12" oc
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
3mm Perforated Aluminum Sheat
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
3 layers plywood fasten to steel studs
with 3 - #8 x 2" long screws
50.8[2"]50[2"]
ST6.3(No14)
DIN7976-C
Aluminum angle
2"x6"x1/8"
508.4[1'-8"]228.6[9"]
ST6.3(No14)
DIN7976-C
Aluminum angle
2"x6"x1/8"
50.8[2"]50[2"]50.4[2"]
994.3 [3'-3 1/8"] to Grid Line V.1
Aluminum Tube
2"x6"x1/8"
M10 threaded rod w/
nut and 25 Dia. washer
Aluminum Holding Plate
20mm Dia.
6mm thick
Aluminum Holding Plate
20mm Dia.
6mm thick
Steel Studs to be designed to support
the following factored load at anchor
locations
Vert. = 0.7 kN (Downwards)
Hor. = 1.7 (Inward or Outward)
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 11 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
SD-26
Section Detail
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/16 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
A12-01, A12-01A, A12-01B, A12-03, A12-05, A12-07
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
143.4 [5 5/8"]
minimum from outer edge of wall
170 [6 3/4"]
M10 Bolt Set
9.8 [3/8"]
18.6 [3/4"]50.8 [2"]101.6 [4"]15.9 [5/8"]
15.9[5/8"]101.6[4"]50.8[2"]18.6[3/4"]
9.8[3/8"]
50.8[2"]
50.8 [2"]
305.6[1']
110[43/8"]256.2[101/8"]50[2"]3[1/8"]
50 [2"]
50[2"]
143.4[55/8"]
50[2"]127[5"]50[2"]
502 [1'-7 3/4"]
502[1'-73/4"]50.8[2"]
50.8 [2"]50 [2"]
50 [2"]
50[2"]
42[15/8"]
42 [1 5/8"]
305.6 [1']
50 [2"] 3 [1/8"]
3 [1/8"]
3 [1/8"]
42[15/8"]
42 [1 5/8"]
ST6.3(No14)
DIN7976-C
ST6.3(No14)
DIN7976-C
M10 Bolt Set
M10threadedRod
ST6.3(No14)
DIN7976-C
50x50x3
Aluminum Tube
EIFS By Others
3mm
Aluminum Angle
35 x3mm (1 3
8'' x 1
8'')
Aluminum
plate pre-connected to slats
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
U bracket connected
to vertical tube through
3 screws ST6.3(No14)
DIN7976-C
Wood blocks from steel stud to steel stud
designed,supplied and installed by others
Blocking and steel studs
to able to support
the following factored loads:
Vert.= 0.7 kN (downwards)
Hor.= 1.7 kN (inward or outward)
50x110x3 SS angle
(height 150mm)
50x110x3 SS angle
(height 150mm)
50x110x3 SS angle
(height 150mm)
Neutral Barrier between SS angle
and aluminum tube to avoid corrosion
Neutral Barrier between SS angle
and aluminum tube to avoid corrosion
2''x4''x 1/8'' Aluminum Slat
Nut & 25mm Dia
Washer
Aluminum U-Shaped
Cap Plate
Outside visible side of bracket
is lapped as shown -
Gastket all locations through envelope
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE 1/2'' = 1'' @ ARCH C (24'' x18'')
PD-02
Plan Detail (Screen)
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
Project ID 15124.03
REFERENCE DRAWINGS
B9-GA8-North East
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
01 16 May 2018 Issued For Approval
127.3 [5"]
304.7 [1']
101.6[4"]
76.2 [3"]
583.3[1'-11"]
101.6 [4"]
25[1"]
151.2[6"]
25.4[1"]
50.
8[2"]
4 mm Aluminum
Composite Panel
Sheathing
by Others
Air & Moisture Barrier
by Others
Membrane on Sheathing
by Others
50.8 [2"]
101.6[4"]
126' - 7'' T/O PARAPET
126' - 5'' T/O STEEL
Seal
124' - 4'' T/O ACP ZONE
1035.3 [3'-4 3/4"] to AXIS 17C
44
[1 3/4
"]
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
Wood Blocking
by Others
Wood Blocking
by Others
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
Steel Studs by Others
(assumed 20GA. thickness
at 16'' OC.)
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
Vertical Joint Profile
Riveted on ACP
(Rivets Finish to match profiles)
Vertical Joint Profile
Riveted on ACP
(Rivets Finish to match profiles)
Trim Flashing
3mm "Z" Shape aluminum
profile
Drainage Hole @ 4' O.C.
Drainage Hole @ 4' O.C.
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
B9-SD10
Section Detail (Parapet)
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/2'' = 1'' @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
01/B9-GA11
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy = 110MPa).
01 16 May 2018 Issued For Approval
44[13/4"]101.6[4"]
15[5/8"]
50.8 [2"]
15 [5/8"]
42 [1 5/8"]
50.8 [2"]
431.3 [1'-5"]
40.9[15/8"]
112.4[43/8"]
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
3mm "Z" Shape aluminum
profile
#10 Grade 410
Stainless Steel
self-drilling screw
Pressure Cap
3mm "Z" Shape aluminum
profile
Shiming
Drip Profile
Pressure cap
Drainage Hole
6x30mm
35[13/8"]
31 [1 1/4"] 487.8 [1'-7 1/4"]
Drainage Hole
6x30mm
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#8 Grade 410
Stainless Steel
self-drilling screw
@ 12" oc
#10 Grade 410
Stainless Steel
self-drilling screw
387.3[1'-31/4"]
116' - 11'' T/O PARAPET
Min. 2% Slope
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
#10 Grade 410
Stainless Steel
self-drilling screw
#8 Grade 410
Stainless Steel
self-drilling screw
@ 12" oc
#8 Grade 410
Stainless Steel
self-drilling screw
@ 12" oc
#10 Grade 410
Stainless Steel
self-drilling screw
@ 16" oc
2mm "U" Shape aluminum
profile (CONTINUOUS)
4 mm Aluminum
Composite Panel (MP2)
DATE
DRAWING NUMBER
DRAWING TITLE
VERSION
VERSION DATE DESCRIPTION
00 03 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 15124.03
SD - 21
Section Detail
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
1/2 @ ARCH C (24'' x18'')
REFERENCE DRAWINGS
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
A13-01, A13-01B, A13-03, A13-05, A13-09
20 Jul 2018
01
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectural
drawings and GC/Framing
-All composite aluminum panels to be by Alpolic
Fire Rated, 4 mm total thickness (2 layers 0.5 mm
THK. Aluminum).
-All self drilling screws to penetrate min. 3 pitches
of thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or 300
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063 T5
(Fy = 110MPa).
-All Stainless steel components to be grade 304
(Fy = 207MPa).
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy=110MPa).
-LePage construction adhesive to be applied and
cured as per manufacturers instructions.
-Dimensions to be verified on site
184.1[71/4"]
31.8[11/4"]31.8[11/4"]
152.3[6"]
50.8 [2"]
FIBER CEMENT PANEL
7 1
4'' x 5
16''
OVERLAP
2mm VERTICAL ALUMINUM PROFILE
at 16'' O.C.
SHIMMING
5
8'' Fibreglass Sheathing
by Others
Air & Moisture Barrier
by Others
119' - 10'' T/O PARAPET
119' - 8'' T/O STEEL
117' - 6'' U/S DECK
422.4 [1'-4 5/8"] to AXIS SS.1
SS1
METAL FLASHING CAP
by OTHERS
CAULKING
by OTHERS
Steel Studs by Others
(assumed 20GA. thickness
at 16'' OC.)
SHIMMING
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
7.2 [9/32"]
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
2mm VERTICAL
ALUMINUM
PROFILE
at 16'' O.C.
Steel Studs by Others
(assumed 20GA. thickness
at 16'' OC.)
25[1"]7.2[1/4"]
SHIMMING
Partial
Plan Detail A
Partial
Plan Detail A
Partial Plan Detail A-A
FIBER CEMENT PANEL
7 1
4'' x 5
16''
FIBER CEMENT PANEL
7 1
4'' x 5
16''
5
8'' Fiberglass
Sheathing
by Others
Air & Moisture
Barrier
by Others
DATE 16 MAY 2018
DRAWING NUMBER
DRAWING TITLE
VERSION
01
VERSION DATE DESCRIPTION
00 06 Apr 2018 Issued For Approval
PROJECT TITLE
SCALE
SD-04
Section Detail (Parapet)
1/2'' = 1'' @ ARCH C (24'' x18'')
DRAWN by S.F. CHECKED by E.F.
TORONTO PREMIUM OUTLETS (Phase 2B)
Project ID 15124.03
REFERENCE DRAWINGS
KEY PLAN
01/B9-GA5
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-15
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TRUST
CONSTRUCTION - MANAGEMENT
BROCCOLINI
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIVE
THE
SPECIFICATIONS
NOTES
- Primary Units are in mm
- All Cladding surfaces had been coordinated to be 2''
outer of the provided sheathing
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Slate Grey - Smooth
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpolic Fire
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, Clear
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58% Open
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpolocn
Fire Rated), Kynar 500 / Hylar 500 – Custom Colour
to match Anodized Storefront – Smooth Finish
-MP7: Perforated Metal Screen, Woven Wire
Mesh, Square Wave, Aluminum Alloy, Intercrimp
weave
const., 2 Mesh, 0,0630’’ Wire, 0,431’’ Opening,
Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized Aluminum
Tube Frame)
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 8530
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis of
Design Allura Stained Lap Siding, Traditional Cedar
Texture, Colour Maple
NOTES
-All composite aluminum panels to be by Alpolic Fire
Rated, 4 mm total thickness (2 layers 0.5 mm THK.
Aluminum).
-All self drilling screws to penetrate min. 3 pitches of
thread into steel member., min. edge distance
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410.
-All aluminum extrusion carrier components to be
min. 2mm thick and grade 6063 T5 (Fy = 110MPa).
01 16 May 2018 Issued For Approval
33 [1 1/4"]
33 [1 3/8"]
33[11/4"]
33[13/8"]
31 [1 1/4"]
31[11/4"]
31 [1 1/4"]
31[11/4"]
44 [1 3/4"]
25[1"]
222[83/4"]
243 [9 5/8"]
51 [2"]
50.8[2"]
50.8 [2"]
50.8[2"]
Sheathing
by Others
Sheathing
by Others
Sheathing
by Others
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#8 Grade 410
Stainless Steel
self-drilling screw
at 12'' OC.
#10 Grade 410
Stainless Steel
self-drilling screw
at 16'' OC.
4 mm Aluminum
Composite Panel
MP2
4 mm Aluminum
Composite Panel
MP1
4 mm Aluminum
Composite Panel MP1
4 mm Aluminum
Composite Panel MP1
482[1'7'']toGridLine18.2
1068 [3' 6''] to Grid Line VV.4
LePage PL9000
construction adhesive,
refer to GA03 & GA04 for
panel locations
DATE
DRAWING NUMBER
DRAWING TITLE
VE
VERSION DATE DESCRIPTION
00 03 Jun 2018 Issued For Approval
PROJECT TITLE
SCALE
Project ID 151
PD-05
Plan Detail
DRAWN by S.F. CHECKED b
TORONTO PREMIUM OUTLETS (Phase
1/2 @ ARCH D (36'' x24'')
REFERENCE DRAWINGS
A13-01, A13-01A, A13-03, A13-05, A13-09, A1
KEY PLAN
OWNERS & DEVELOPERS
ARCHITECT - CONSULTANT
CONTRACTOR
CLADDING
SYSTEM
W 14-
S I M O NPREMIUM OUTLETS
CALLOWAYREAL ESTATE INVESTMENT TR
CONSTRUCTION - MANAGEMENT
BROCCOLIN
PETROFFPARTNERSHIP ARCHITECTS
DESIGN ARCHITECT
COLLABORATIV
THE
SPECIFICATIONS
METAL PANELS
-MP1: 4 mm Aluminum Composite Panel (Alpo
Rated), Kynar 500 / Hylar 500 – Slate Grey - Sm
Finish
-MP2: 4 mm Aluminum Composite Panel (Alpo
Rated), Kynar 500 / Hylar 500 – Dove
Grey – Smooth Finish
-MP3: 4 mm Aluminum Composite Panel (Alpo
Rated), Kynar 500 / Hylar 500 – Medium
Bronze – Smooth Finish
-MP4: Perforated Metal
Screen, Alum. Type 3003-H14, 0.125 Gauge, C
Anodized Finish, Round Holes
¼’’ on 5/16’’ centers, Staggered Pattern, 58%
Area, Sheet 4’Wx10’L (MTD to 2’’x2’’ Anodized
Aluminum Tube Frame)
-MP5: Horizontal Slat Screen, Powder Coated
Aluminum (Colour Medium Bronze), MTD
to 2’’x2’’ Anodized Aluminum Tube Framing
-MP6: 4 mm Aluminum Composite Panel (Alpo
Fire Rated), Kynar 500 / Hylar 500 – Custom C
to match Anodized Storefront – Smooth Finish
-A1, A2: 4 mm Aluminum Composite Panel for
canopies’ cladding
MASONRY
-B1: Thin Brick Veneer System, Running Bond -
Belden Mayo Blend (2-1/4''Hx3/4''Dx7-5/8''W)
-B2: Thin Brick Veneer System, Belden No. 853
(2-1/4''Hx3/4''Dx7-5/8''W)
-S1: Cast Stone Sill
CLADDING
-CL1: Fiber Cement Siding (6'' Exposure), Basis
Design Allura Stained Lap Siding, Traditional Ce
Texture, Colour Maple
20 Jul 2018
01 20 Jul 2018 Issued For Approval
NOTES
- Primary Units are in mm
- Sheathing to be coordinated with Architectu
drawings and GC/Framing
-All composite aluminum panels to be by Alp
Fire Rated, 4 mm total thickness (2 layers 0.
THK. Aluminum).
-All self drilling screws to penetrate min. 3 pi
of thread into steel member., min. edge dista
1.5xdia., min. spacing 2.5xdia.
-All screws to be stainless steel grade 410 or
series if exposed.
-All Bolts to be grade 304.
-All aluminum components to be grade 6063
(Fy = 110MPa).
-All Stainless steel components to be grade 3
(Fy = 207MPa).
-All aluminum extrusion carrier components
min. 2mm thick and grade 6063 T5 (Fy=110
-LePage construction adhesive to be applied
cured as per manufacturers instructions.
-Dimensions to be verified on site
12. 52013-2018
Assignment of:
-New Aluminum Cladding System
development (H-2040)
-Tender Stage Estimation
-Shop Drawings
-Bill of Materials
-Fabrication Drawings
-Installation Drawings
Scope of Work:
-Ceramic Panels Cladding
-Enamel Porcelain Panels Cladding
-Stainless Steel Panels Cladding
HIGHWAY
407
STATION
Toronto, Canada