Fire Safety of Rooming Houses
(SECTION 9.3 BOARDING, LODGING AND ROOMING HOUSES, ONTARIO FIRE CODE, 2015)
Davis, G. 2019, Ontario Fire Marshal investigate rooming house fire in Peterborough, Global News, accessed 22, February, 2021, <https://globalnews.ca/news/5117008/ontario-fire-marshal-
investigate-rooming-house-fire-peterborough/>
Purpose
After completing this lesson, the participants shall be able to understand and
apply the set Ontario Fire Safety Code (2015) to their properties; including
containment, means of egress, fire alarm and detection and suppression
Learning Objectives
Upon successful completion of this lesson, the student shall be
able to:
Understand and apply the Fire Safety of Rooming Housing (Section 9.3 Boarding, Lodging and Rooming Houses, Ontario
Fire Code, 2015).
Understand an apply Section 9.3; subsection 9.3.2. and apply regulations pertaining to containment, fire separations
and fire resistance.
Understand and apply: Section 9.3; subsection 9.3.3. and apply regulations pertaining means of egress; number of
exits, acceptable exits, fire escapes signage, lighting, and safe exiting of the premises.
Understand an apply Section 9.3; subsection 9.3.4. and apply regulations pertaining fire alarm and detection, ensuring
occupant safety, fire-resistant ratings, smoke alarms, smoke detectors, fire alarms and placement of devices.
Understand an apply Section 9.3; subsection 9.3.5. and apply regulations pertaining suppression, fire extinguishers and
shared kitchen areas found in rooming houses.
What are Rooming Houses?
A Rooming House can be a converted house, apartment or building
where there is a shared kitchen and/or washroom with four or more
people who each pay individual rent.
There are some municipalities in the Province of Ontario that require
the property owner to be licensed as a Rooming House
Operator/Owner.
City of Toronto. (2021). Rooming Houses. [online]. Retrieved from https://www.toronto.ca/community-people/public-safety-
alerts/safety-tips-prevention/home-high-rise-school-workplace-safety/low-rise-small-multi-unit-residential-fire-safety/rooming-
houses/
Example of a Rooming House Layout
Risks of Fire and Injury in Rooming Houses
Why are Rooming Houses a Risk?
Renovations are done without City review/approval – no building permits
Not enough exits for Basement, 2nd and 3rd floor units ( at least 2 exits are required)
 Open stairs or enclosed stairs leading to outdoors are not exits
Lack of interconnected smoke/CO alarms or any fire alarms throughout the home – due to no building permit
Interior finished are not to CODE and increase the flame spread speed
Insufficient electrical loads (not upgrades) or upgrades are not ESA (Electrical Safety Authority) inspected/approved
Occupants do not know each other (population is transient)
Individual occupant’s rooms are locked
Occupants overload what few electrical outlets within their rooms using adapters.
Fire Safety of Rooming Houses, OFC, 2015,
Section 9.3
SECTION 9.3 BOARDING, LODGING AND ROOMING HOUSES
Subsection 9.3.1. Application and General
Application
9.3.1.1. (1) This Section applies to boarding houses, lodging houses, rooming houses and private rest homes in which residents
do not require care or treatment because of age, mental or physical limitations, where
(a) the building height does not exceed 3 storeys and the building area does not exceed 600 m2,
(b) lodging is provided for more than four persons in return for remuneration or the provision of services or both,
and
(c) lodging rooms do not have both bathrooms and kitchen facilities for the exclusive use of individual
occupants.
(2) This Section applies to homes for special care within the meaning of the Homes for Special Care Act, where
(a) the building height does not exceed 3 storeys and the building area does not exceed 600 m2,
(b) sleeping accommodation is provided for more than three but not more than 10 residents, and
(c) residents do not require nursing care.
(3) REVOKED: O. Reg. 256/14, s. 327. Exemption for Ministry of Community and Social Services (MCSS) residences and
hotels
Definitions
9.3.1.3. For the purposes of this Section,
“1986 Building Code” means Ontario Regulation 419/86, as it read on
February 11, 1987;
“existing” means in existence on February 11, 1987.
Subsection 9.3.2. Containment
9.3.2.1. Fire separations required by this Section to have a fire-
resistance rating shall comply with Subsection 9.10.3. of the 1986
Building Code
Floor Assemblies
9.3.2.2. (1) Floor assemblies shall
(a) be constructed as fire separations, and
(b) have a fire-resistance rating not less than 30 min.
(2) Existing floor assemblies with ceilings consisting of lath and
plaster, gypsum board or non-combustible materials are deemed to be
in compliance with Sentence (1).
Basement Fire Separations
9.3.2.3. Where a basement does not contain a bedroom,
recreation room, meeting room or hobby room, a fire
separation having no fire-resistance rating between the
basement and first storey is deemed to be in compliance with
Clause 9.3.2.2.(1)(b).
Wall Separating Bedrooms
9.3.2.4. (1) Each guest room or suite of rooms shall have
interior walls having a fire-resistance rating not less than 30
min.
(2) Existing wall assemblies consisting of membranes of lath
and plaster or gypsum wallboard are deemed to be in
compliance with Sentence (1).
Furnace Room Separations
According to 9.3.2.5. Furnace Room Separations are:
(1) In a building where the building height is greater than 2 storeys or the building area is greater than 400 m2, a furnace
room that is located on a floor area that contains a bedroom, recreation room, meeting room or hobby room shall be separated
from the remainder of the building by a fire separation having a fire-resistance rating not less than 45 min.
(2) Existing fire separations consisting of membranes of lath and plaster or gypsum board are deemed to be in compliance
with Sentence (1).
(3) Where the required vertical fire separation in a furnace room is maintained and it is not practical in the circumstances to
construct the ceiling as a fire separation having a fire-resistance rating not less than 45 min, the furnace room area shall be
sprinklered with a spacing that does not exceed 9.5 m2 per sprinkler head.
(4) Closures in fire separations for a furnace room shall have a fire-protection rating not less than 45 min.
(5) A hollow metal or kalamein door and frame are deemed to be in compliance with Sentence (4).
(6) Closures referred to in Sentences (4) and (5) shall be equipped with latches and self-closing devices.
(7) Despite Sentence (1), fire dampers or fire-stop flaps are not required in ducts at penetrations of a fire separation.
Combustion Air
9.3.2.6. Where a furnace room is separated to comply with the
requirements of Article 9.3.2.5., sufficient combustion air shall be
brought directly from the exterior for the proper combustion and
safe operation of the appliance.
Number of Exits
Subsection 9.3.3. Means of Egress
9.3.3.1. (1) Each floor area shall be served by at least two exits.
(2) Where sleeping accommodation is not provided for more than 10
persons, one exit from each of the first and second floor - floor areas is
deemed to be in compliance with Sentence (1).
(3) Where sleeping accommodation is not provided in the basement,
one exit from the basement is deemed to be in compliance with
Sentence (1).
Acceptable Exits
9.3.3.2. (1) Exits required by Article 9.3.3.1. shall comply with the requirements of Articles 9.9.2.2. and 9.9.2.3. of
the 1986 Building Code.
(2) Despite Sentence 9.3.3.5.(1), not more than one required exit from the basement may lead through the first
floor floor area.
(3) Where sleeping accommodation is not provided for more than 10 persons, corridors that are contiguous to a
stairway may form part of the stairway enclosure.
(4) Only one stairway enclosure described in Sentence (3) may be used as an exit.
(5) Where a fire escape of the type referred to in Article 9.3.3.4. is used as an exit, it is deemed to comply with the
requirements of Articles 9.9.2.2. and 9.9.2.3. of the 1986 Building Code.
9.3.3.3. Despite Articles 9.3.3.1. and 9.3.3.2., alternative measures may be approved where, in the opinion of the
Chief Fire Official, they will provide protection for life safety similar to the protection provided by compliance with
Articles 9.3.3.1. and 9.3.3.2.
Fire Escapes
9.3.3.4. (1) Each fire escape used as an exit shall be
constructed in compliance with Article 3.4.7.13., excluding
Sentences (4) and (5), of the 1986 Building Code.
(2) Despite Sentence (1), existing fire escapes may be
approved.
(3) Access to fire escapes shall be from corridors.
Protection of Exists
9.3.3.5. (1) Each exit other than a doorway opening directly onto a
fire escape or to the outdoors at ground level shall be separated from
the remainder of the building or from another exit by a fire separation
having a fire-resistance rating not less than 30 min.
(2) Existing exit stairways separated from the remainder of the
building by walls consisting of lath and plaster or gypsum wallboard
are deemed to be in compliance with Sentence (1).
(3) Despite Sentence (1), an existing separation of noncombustible
material may be approved.
Interior Stairways
9.3.3.6. (1) Floor separations shall be maintained at interior
stairways that are not required exits.
(2) The floor separation shall be maintained at an exit
permitted in Sentence 9.3.3.2.(2).
9.3.3.7. Floor separations required in Article 9.3.3.6. shall be
rated in accordance with Articles 9.3.2.2. and 9.3.3.5.
Protection of Openings in Fire Separations
9.3.3.8. (1) Closures in fire separations required under Article 9.3.3.5. and in floor separations required under Article 9.3.3.6.
shall
(a) be constructed in accordance with Article 9.10.3.1. of the 1986 Building Code,
(b) have a fire-protection rating not less than 20 min, and
(c) if the closure is openable, be equipped with self-closing and latching devices.
(2) Closures located along contiguous corridors permitted in Sentence 9.3.3.2.(3) shall comply with Sentence (1).
(3) A 45 mm solid core wood, hollow metal or kalamein door, equipped with self-closing and latching devices, is deemed to
comply with Sentences (1) and (2).
(4) Despite Sentences (1) and (2), frames for doors described in Sentence (3) may be of wood, hollow metal or kalamein
construction.
(5) Despite Sentences (1) and (2), fire dampers or fire-stop flaps are not required in ducts at penetrations of a fire separation.
9.3.3.9. Existing wired glass closures set in fixed steel frames in a fire separation are deemed to be in compliance with Article
9.3.3.8.
Exit Signs
9.3.3.10. (1) Exit signs shall be located along a means of egress so that directions
of exit travel are apparent to the occupants.
(2) Exit signs required by Sentence (1) shall have the word “EXIT” in block letters
and such letters shall be
(a) internally or externally illuminated,
(b) coloured red on an opaque or contrasting field, and
(c) at least 115 mm high with a 19 mm stroke.
Interior Finishes
9.3.3.11. The flame-spread rating of interior finishes
on walls and ceilings within a means of egress shall not
exceed 200.
Illumination and Emergency Lighting
Illumination of egress
9.3.3.12. Corridors and stairways shall be lighted to the intensity of 50 lx
measured at the floor level, or 5 watts/m2 of floor area.
Emergency lighting
9.3.3.13. Where sleeping accommodation is provided for more than 10 persons,
emergency lighting shall be provided to corridors and stairways in accordance with
Articles 9.9.11.4. and 9.9.11.5. of the 1986 Building Code.
Fire Alarms, Detectors etc.
Fire alarm requirements
9.3.4.1. (1) A building to which this Section applies that does not have floor assemblies having a minimum 45 min
fire-resistance rating and public corridors or corridors serving sleeping rooms not within a dwelling unit that are not
fire-separated from the remainder of the building by a minimum 30 min fire-resistance rating shall have a fire alarm
system that complies with Articles 9.10.17.5. and 9.10.17.11. of the 1986 Building Code, and shall have
(a) smoke alarms that comply with Sentence (2) and that are installed and interconnected so that the
activation of any smoke alarm will sound a similar signal in each of the interconnected devices, or
(b) fire alarm system smoke detectors installed on the ceiling of each floor adjacent to each stairway,
and on the ceiling in the basement adjacent to each stairway.
Continued….
(2) Smoke alarms referred to in Clause (1)(a) shall
(a) be installed on the ceiling in the corridor of each floor adjacent to each stairway and on the ceiling in the
basement adjacent to each stairway,
(b) be on a separate circuit with no disconnect switch between the overcurrent device and the smoke alarms, and
(c) employ devices and an interconnected installation that are listed.
9.3.4.2. (1) A fire alarm system complying with Articles 9.10.17.4., 9.10.17.5., 9.10.17.11. and Subsection 9.10.18. of the 1986
Building Code shall be installed where
(a) sleeping accommodation is provided for more than 10 persons, and
(b) the floor assemblies have a fire-resistance rating not less than 45 min and public corridors or corridors serving
sleeping rooms not within a dwelling unit are separated from the remainder of the building by fire separations having a fire-
resistance rating not less than 30 min.
9.3.4.3. Where a fire alarm system is required and sleeping accommodation is not provided for more than 14 persons, an
interconnected smoke alarm system in accordance with Clause 9.3.4.1.(1)(a) is deemed to be in compliance with Article 9.3.4.2.
9.3.4.4. Despite Articles 9.3.4.1. and 9.3.4.2., existing fire alarm systems may be approved where the system reliability and
performance will not increase the risk of life safety.
Suppression
Portable extinguishers
9.3.5.1. (1) Despite the provisions of Subsection 6.2.6., at
least one 2A rated portable extinguisher shall be provided on
each floor.
(2) At least one 5B:C rated portable extinguisher shall be
installed in each kitchen where shared cooking facilities exist.
Kitchen-Related
Safety
Conclusion
The importance of fire safety of Rooming Houses lies
in the need to provide its occupants with safe living
conditions as it relates to fire safety and provide
education to property owners.

More Related Content

Similar to Fire safey of rooming houses

Similar to Fire safey of rooming houses (20)

BIS Fire Resistant Design 27.06.2022_compressed.pdf
BIS Fire Resistant Design 27.06.2022_compressed.pdfBIS Fire Resistant Design 27.06.2022_compressed.pdf
BIS Fire Resistant Design 27.06.2022_compressed.pdf
 
Chap 7 ventilation and smoke purging system
Chap 7 ventilation and smoke purging systemChap 7 ventilation and smoke purging system
Chap 7 ventilation and smoke purging system
 
ARC401 report
ARC401 reportARC401 report
ARC401 report
 
Session 10
Session 10Session 10
Session 10
 
Session 12
Session 12Session 12
Session 12
 
B.service
B.serviceB.service
B.service
 
Building services
Building servicesBuilding services
Building services
 
Session 4
Session 4Session 4
Session 4
 
Mill 14-1-15 - Sheet - A108 - BUILDING REGULATIONS ...
Mill 14-1-15 - Sheet - A108 - BUILDING REGULATIONS                           ...Mill 14-1-15 - Sheet - A108 - BUILDING REGULATIONS                           ...
Mill 14-1-15 - Sheet - A108 - BUILDING REGULATIONS ...
 
BCT - Module 5 special treatment part 3
BCT - Module 5 special treatment part 3BCT - Module 5 special treatment part 3
BCT - Module 5 special treatment part 3
 
Sargas Stove System Brochure
Sargas Stove System Brochure Sargas Stove System Brochure
Sargas Stove System Brochure
 
Fire regulations for buildings
Fire regulations for buildingsFire regulations for buildings
Fire regulations for buildings
 
Chapter 4 ventilation
Chapter 4 ventilationChapter 4 ventilation
Chapter 4 ventilation
 
Sub floor code
Sub floor codeSub floor code
Sub floor code
 
Fire proof finish
Fire proof finishFire proof finish
Fire proof finish
 
Fire regulation service sector Mauritius
Fire regulation service sector MauritiusFire regulation service sector Mauritius
Fire regulation service sector Mauritius
 
Fire and Flat Roofs #SPRAConference2019
Fire and Flat Roofs #SPRAConference2019Fire and Flat Roofs #SPRAConference2019
Fire and Flat Roofs #SPRAConference2019
 
Session 3
Session 3Session 3
Session 3
 
Ardiente. Bustamante. Diaz - RULE VIII (2).pdf
Ardiente. Bustamante. Diaz - RULE VIII (2).pdfArdiente. Bustamante. Diaz - RULE VIII (2).pdf
Ardiente. Bustamante. Diaz - RULE VIII (2).pdf
 
2 building enclosures #2 (2014)
2 building enclosures #2 (2014)2 building enclosures #2 (2014)
2 building enclosures #2 (2014)
 

Recently uploaded

Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.pptRamjanShidvankar
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jisc
 
Google Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptxGoogle Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptxDr. Sarita Anand
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...Poonam Aher Patil
 
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxOn_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxPooja Bhuva
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxAreebaZafar22
 
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...Amil baba
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxDenish Jangid
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsKarakKing
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxJisc
 
Key note speaker Neum_Admir Softic_ENG.pdf
Key note speaker Neum_Admir Softic_ENG.pdfKey note speaker Neum_Admir Softic_ENG.pdf
Key note speaker Neum_Admir Softic_ENG.pdfAdmir Softic
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfPoh-Sun Goh
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Pooja Bhuva
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024Elizabeth Walsh
 
Fostering Friendships - Enhancing Social Bonds in the Classroom
Fostering Friendships - Enhancing Social Bonds  in the ClassroomFostering Friendships - Enhancing Social Bonds  in the Classroom
Fostering Friendships - Enhancing Social Bonds in the ClassroomPooky Knightsmith
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...ZurliaSoop
 
ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.MaryamAhmad92
 
Understanding Accommodations and Modifications
Understanding  Accommodations and ModificationsUnderstanding  Accommodations and Modifications
Understanding Accommodations and ModificationsMJDuyan
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxheathfieldcps1
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...pradhanghanshyam7136
 

Recently uploaded (20)

Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.ppt
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)
 
Google Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptxGoogle Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptx
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...
 
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptxOn_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
On_Translating_a_Tamil_Poem_by_A_K_Ramanujan.pptx
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functions
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptx
 
Key note speaker Neum_Admir Softic_ENG.pdf
Key note speaker Neum_Admir Softic_ENG.pdfKey note speaker Neum_Admir Softic_ENG.pdf
Key note speaker Neum_Admir Softic_ENG.pdf
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdf
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024
 
Fostering Friendships - Enhancing Social Bonds in the Classroom
Fostering Friendships - Enhancing Social Bonds  in the ClassroomFostering Friendships - Enhancing Social Bonds  in the Classroom
Fostering Friendships - Enhancing Social Bonds in the Classroom
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
 
ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.
 
Understanding Accommodations and Modifications
Understanding  Accommodations and ModificationsUnderstanding  Accommodations and Modifications
Understanding Accommodations and Modifications
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptx
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
 

Fire safey of rooming houses

  • 1. Fire Safety of Rooming Houses (SECTION 9.3 BOARDING, LODGING AND ROOMING HOUSES, ONTARIO FIRE CODE, 2015) Davis, G. 2019, Ontario Fire Marshal investigate rooming house fire in Peterborough, Global News, accessed 22, February, 2021, <https://globalnews.ca/news/5117008/ontario-fire-marshal- investigate-rooming-house-fire-peterborough/>
  • 2. Purpose After completing this lesson, the participants shall be able to understand and apply the set Ontario Fire Safety Code (2015) to their properties; including containment, means of egress, fire alarm and detection and suppression
  • 3. Learning Objectives Upon successful completion of this lesson, the student shall be able to: Understand and apply the Fire Safety of Rooming Housing (Section 9.3 Boarding, Lodging and Rooming Houses, Ontario Fire Code, 2015). Understand an apply Section 9.3; subsection 9.3.2. and apply regulations pertaining to containment, fire separations and fire resistance. Understand and apply: Section 9.3; subsection 9.3.3. and apply regulations pertaining means of egress; number of exits, acceptable exits, fire escapes signage, lighting, and safe exiting of the premises. Understand an apply Section 9.3; subsection 9.3.4. and apply regulations pertaining fire alarm and detection, ensuring occupant safety, fire-resistant ratings, smoke alarms, smoke detectors, fire alarms and placement of devices. Understand an apply Section 9.3; subsection 9.3.5. and apply regulations pertaining suppression, fire extinguishers and shared kitchen areas found in rooming houses.
  • 4. What are Rooming Houses? A Rooming House can be a converted house, apartment or building where there is a shared kitchen and/or washroom with four or more people who each pay individual rent. There are some municipalities in the Province of Ontario that require the property owner to be licensed as a Rooming House Operator/Owner. City of Toronto. (2021). Rooming Houses. [online]. Retrieved from https://www.toronto.ca/community-people/public-safety- alerts/safety-tips-prevention/home-high-rise-school-workplace-safety/low-rise-small-multi-unit-residential-fire-safety/rooming- houses/
  • 5. Example of a Rooming House Layout
  • 6. Risks of Fire and Injury in Rooming Houses Why are Rooming Houses a Risk? Renovations are done without City review/approval – no building permits Not enough exits for Basement, 2nd and 3rd floor units ( at least 2 exits are required)  Open stairs or enclosed stairs leading to outdoors are not exits Lack of interconnected smoke/CO alarms or any fire alarms throughout the home – due to no building permit Interior finished are not to CODE and increase the flame spread speed Insufficient electrical loads (not upgrades) or upgrades are not ESA (Electrical Safety Authority) inspected/approved Occupants do not know each other (population is transient) Individual occupant’s rooms are locked Occupants overload what few electrical outlets within their rooms using adapters.
  • 7. Fire Safety of Rooming Houses, OFC, 2015, Section 9.3 SECTION 9.3 BOARDING, LODGING AND ROOMING HOUSES Subsection 9.3.1. Application and General Application 9.3.1.1. (1) This Section applies to boarding houses, lodging houses, rooming houses and private rest homes in which residents do not require care or treatment because of age, mental or physical limitations, where (a) the building height does not exceed 3 storeys and the building area does not exceed 600 m2, (b) lodging is provided for more than four persons in return for remuneration or the provision of services or both, and (c) lodging rooms do not have both bathrooms and kitchen facilities for the exclusive use of individual occupants. (2) This Section applies to homes for special care within the meaning of the Homes for Special Care Act, where (a) the building height does not exceed 3 storeys and the building area does not exceed 600 m2, (b) sleeping accommodation is provided for more than three but not more than 10 residents, and (c) residents do not require nursing care. (3) REVOKED: O. Reg. 256/14, s. 327. Exemption for Ministry of Community and Social Services (MCSS) residences and hotels
  • 8. Definitions 9.3.1.3. For the purposes of this Section, “1986 Building Code” means Ontario Regulation 419/86, as it read on February 11, 1987; “existing” means in existence on February 11, 1987. Subsection 9.3.2. Containment 9.3.2.1. Fire separations required by this Section to have a fire- resistance rating shall comply with Subsection 9.10.3. of the 1986 Building Code
  • 9. Floor Assemblies 9.3.2.2. (1) Floor assemblies shall (a) be constructed as fire separations, and (b) have a fire-resistance rating not less than 30 min. (2) Existing floor assemblies with ceilings consisting of lath and plaster, gypsum board or non-combustible materials are deemed to be in compliance with Sentence (1).
  • 10. Basement Fire Separations 9.3.2.3. Where a basement does not contain a bedroom, recreation room, meeting room or hobby room, a fire separation having no fire-resistance rating between the basement and first storey is deemed to be in compliance with Clause 9.3.2.2.(1)(b).
  • 11. Wall Separating Bedrooms 9.3.2.4. (1) Each guest room or suite of rooms shall have interior walls having a fire-resistance rating not less than 30 min. (2) Existing wall assemblies consisting of membranes of lath and plaster or gypsum wallboard are deemed to be in compliance with Sentence (1).
  • 12. Furnace Room Separations According to 9.3.2.5. Furnace Room Separations are: (1) In a building where the building height is greater than 2 storeys or the building area is greater than 400 m2, a furnace room that is located on a floor area that contains a bedroom, recreation room, meeting room or hobby room shall be separated from the remainder of the building by a fire separation having a fire-resistance rating not less than 45 min. (2) Existing fire separations consisting of membranes of lath and plaster or gypsum board are deemed to be in compliance with Sentence (1). (3) Where the required vertical fire separation in a furnace room is maintained and it is not practical in the circumstances to construct the ceiling as a fire separation having a fire-resistance rating not less than 45 min, the furnace room area shall be sprinklered with a spacing that does not exceed 9.5 m2 per sprinkler head. (4) Closures in fire separations for a furnace room shall have a fire-protection rating not less than 45 min. (5) A hollow metal or kalamein door and frame are deemed to be in compliance with Sentence (4). (6) Closures referred to in Sentences (4) and (5) shall be equipped with latches and self-closing devices. (7) Despite Sentence (1), fire dampers or fire-stop flaps are not required in ducts at penetrations of a fire separation.
  • 13. Combustion Air 9.3.2.6. Where a furnace room is separated to comply with the requirements of Article 9.3.2.5., sufficient combustion air shall be brought directly from the exterior for the proper combustion and safe operation of the appliance.
  • 14. Number of Exits Subsection 9.3.3. Means of Egress 9.3.3.1. (1) Each floor area shall be served by at least two exits. (2) Where sleeping accommodation is not provided for more than 10 persons, one exit from each of the first and second floor - floor areas is deemed to be in compliance with Sentence (1). (3) Where sleeping accommodation is not provided in the basement, one exit from the basement is deemed to be in compliance with Sentence (1).
  • 15. Acceptable Exits 9.3.3.2. (1) Exits required by Article 9.3.3.1. shall comply with the requirements of Articles 9.9.2.2. and 9.9.2.3. of the 1986 Building Code. (2) Despite Sentence 9.3.3.5.(1), not more than one required exit from the basement may lead through the first floor floor area. (3) Where sleeping accommodation is not provided for more than 10 persons, corridors that are contiguous to a stairway may form part of the stairway enclosure. (4) Only one stairway enclosure described in Sentence (3) may be used as an exit. (5) Where a fire escape of the type referred to in Article 9.3.3.4. is used as an exit, it is deemed to comply with the requirements of Articles 9.9.2.2. and 9.9.2.3. of the 1986 Building Code. 9.3.3.3. Despite Articles 9.3.3.1. and 9.3.3.2., alternative measures may be approved where, in the opinion of the Chief Fire Official, they will provide protection for life safety similar to the protection provided by compliance with Articles 9.3.3.1. and 9.3.3.2.
  • 16. Fire Escapes 9.3.3.4. (1) Each fire escape used as an exit shall be constructed in compliance with Article 3.4.7.13., excluding Sentences (4) and (5), of the 1986 Building Code. (2) Despite Sentence (1), existing fire escapes may be approved. (3) Access to fire escapes shall be from corridors.
  • 17. Protection of Exists 9.3.3.5. (1) Each exit other than a doorway opening directly onto a fire escape or to the outdoors at ground level shall be separated from the remainder of the building or from another exit by a fire separation having a fire-resistance rating not less than 30 min. (2) Existing exit stairways separated from the remainder of the building by walls consisting of lath and plaster or gypsum wallboard are deemed to be in compliance with Sentence (1). (3) Despite Sentence (1), an existing separation of noncombustible material may be approved.
  • 18. Interior Stairways 9.3.3.6. (1) Floor separations shall be maintained at interior stairways that are not required exits. (2) The floor separation shall be maintained at an exit permitted in Sentence 9.3.3.2.(2). 9.3.3.7. Floor separations required in Article 9.3.3.6. shall be rated in accordance with Articles 9.3.2.2. and 9.3.3.5.
  • 19. Protection of Openings in Fire Separations 9.3.3.8. (1) Closures in fire separations required under Article 9.3.3.5. and in floor separations required under Article 9.3.3.6. shall (a) be constructed in accordance with Article 9.10.3.1. of the 1986 Building Code, (b) have a fire-protection rating not less than 20 min, and (c) if the closure is openable, be equipped with self-closing and latching devices. (2) Closures located along contiguous corridors permitted in Sentence 9.3.3.2.(3) shall comply with Sentence (1). (3) A 45 mm solid core wood, hollow metal or kalamein door, equipped with self-closing and latching devices, is deemed to comply with Sentences (1) and (2). (4) Despite Sentences (1) and (2), frames for doors described in Sentence (3) may be of wood, hollow metal or kalamein construction. (5) Despite Sentences (1) and (2), fire dampers or fire-stop flaps are not required in ducts at penetrations of a fire separation. 9.3.3.9. Existing wired glass closures set in fixed steel frames in a fire separation are deemed to be in compliance with Article 9.3.3.8.
  • 20. Exit Signs 9.3.3.10. (1) Exit signs shall be located along a means of egress so that directions of exit travel are apparent to the occupants. (2) Exit signs required by Sentence (1) shall have the word “EXIT” in block letters and such letters shall be (a) internally or externally illuminated, (b) coloured red on an opaque or contrasting field, and (c) at least 115 mm high with a 19 mm stroke.
  • 21. Interior Finishes 9.3.3.11. The flame-spread rating of interior finishes on walls and ceilings within a means of egress shall not exceed 200.
  • 22. Illumination and Emergency Lighting Illumination of egress 9.3.3.12. Corridors and stairways shall be lighted to the intensity of 50 lx measured at the floor level, or 5 watts/m2 of floor area. Emergency lighting 9.3.3.13. Where sleeping accommodation is provided for more than 10 persons, emergency lighting shall be provided to corridors and stairways in accordance with Articles 9.9.11.4. and 9.9.11.5. of the 1986 Building Code.
  • 23. Fire Alarms, Detectors etc. Fire alarm requirements 9.3.4.1. (1) A building to which this Section applies that does not have floor assemblies having a minimum 45 min fire-resistance rating and public corridors or corridors serving sleeping rooms not within a dwelling unit that are not fire-separated from the remainder of the building by a minimum 30 min fire-resistance rating shall have a fire alarm system that complies with Articles 9.10.17.5. and 9.10.17.11. of the 1986 Building Code, and shall have (a) smoke alarms that comply with Sentence (2) and that are installed and interconnected so that the activation of any smoke alarm will sound a similar signal in each of the interconnected devices, or (b) fire alarm system smoke detectors installed on the ceiling of each floor adjacent to each stairway, and on the ceiling in the basement adjacent to each stairway.
  • 24. Continued…. (2) Smoke alarms referred to in Clause (1)(a) shall (a) be installed on the ceiling in the corridor of each floor adjacent to each stairway and on the ceiling in the basement adjacent to each stairway, (b) be on a separate circuit with no disconnect switch between the overcurrent device and the smoke alarms, and (c) employ devices and an interconnected installation that are listed. 9.3.4.2. (1) A fire alarm system complying with Articles 9.10.17.4., 9.10.17.5., 9.10.17.11. and Subsection 9.10.18. of the 1986 Building Code shall be installed where (a) sleeping accommodation is provided for more than 10 persons, and (b) the floor assemblies have a fire-resistance rating not less than 45 min and public corridors or corridors serving sleeping rooms not within a dwelling unit are separated from the remainder of the building by fire separations having a fire- resistance rating not less than 30 min. 9.3.4.3. Where a fire alarm system is required and sleeping accommodation is not provided for more than 14 persons, an interconnected smoke alarm system in accordance with Clause 9.3.4.1.(1)(a) is deemed to be in compliance with Article 9.3.4.2. 9.3.4.4. Despite Articles 9.3.4.1. and 9.3.4.2., existing fire alarm systems may be approved where the system reliability and performance will not increase the risk of life safety.
  • 25. Suppression Portable extinguishers 9.3.5.1. (1) Despite the provisions of Subsection 6.2.6., at least one 2A rated portable extinguisher shall be provided on each floor. (2) At least one 5B:C rated portable extinguisher shall be installed in each kitchen where shared cooking facilities exist.
  • 27. Conclusion The importance of fire safety of Rooming Houses lies in the need to provide its occupants with safe living conditions as it relates to fire safety and provide education to property owners.

Editor's Notes

  1. Welcome to Fire Safety of Rooming Houses. This lesson will cover basic fire safety regulations set out by the Ontario Fire Code (2015) with a focus on Section 9.3, Boarding, Lodging and Rooming Houses. This session will provide homeowners with information pertaining to Fire Safety regulations including containment, means of egress, fire alarm and detection and suppression. My name is Mira Kapetanovic and it is my pleasure to be presenting this information to you today.  
  2. The purpose of this lesson is to educate and provide information to those home/property owners who either have or are considering converting their single-family dwelling home into rooming house to provide accommodation during the current housing crisis in the Greater Toronto Area (GTA).
  3. The Learning objectives have been designed to target each of the key components as outline in the Ontario Fire Code – section 9.3 which directly relates to the fire safety regulations of rooming houses. Upon completion of this lecture/workshop, the participants will complete an exam to establish comprehension of the content and evaluation of said learning outcomes. Participants will then be issued a certificate of completions pending the result of the exam. Participants will be required to earn a grade of at least 80% for a certificate to be issued. This certificate will then be provided to the local Fire Prevention Inspector to be granted approval for property owners to proceed with converting their homes into rooming houses and will also qualify property owners to book an appointment for an inspection before approval.
  4. The above are risks that exist and are common in rooming houses.
  5. This is an excerpt from the Ontario Fire Code (2015) Section 9.3. Instructor will explain the contents of this section.
  6. Instructor will explain key points found in this definition.
  7. Instructor will explain floor assemblies ( fire separations/fire resistance ratings/combustible materials) as they relate to floor assemblies.
  8. Instructor will explain basement/ basement room regulations as per Section 9.3 subsection 2.3
  9. Instructor will explain wall separations.
  10. Instructor will explain the contents of Furnace Room Separations.
  11. Instructor will explain combustion air as a continuation of the furnace room separation noted in pervious slide.
  12. Instructor will explain “means of egress” and exits required in a rooming house.
  13. Instructor will explain as a continuation from previous slide the regulations of acceptable exists in rooming houses.
  14. Instructor will explain Fire Escapes.
  15. Instructor will explain the importance of exists and maintaining access to exits.
  16. Instructor will explain stairways (interior) in rooming houses.
  17. Instructor will explain the importance of openings in fire separations.
  18. Instructor will explain exit signage and where signage is required along the means of egress so as to direct occupants to exits.
  19. Instructor will explain interior finishes as per flame-spreading ratings.
  20. Instructor will explain illumination of corridors and emergency lighting.
  21. Instructor will explain the importance of fire alarms and detectors in rooming houses.
  22. Instructor will continue from the last slide and explain additional information pertaining to smoke alarms.
  23. Instructor will explain suppression and portable extinguishers.
  24. Instructor will review Kitchen Fire Safety.
  25. Instructor will summarize the contents of this lesson and provide a conclusion. Instructor will take questions and administer exam/provide link to exam.