SlideShare a Scribd company logo
1 of 10
Download to read offline
Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Leader in Lighting & Electrical Test Instruments
Rev. 10/18/2019
LED Lumen Maintenance and Life
Test System
(LEDLM-80PL)
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
System Principle
Rated Lumen Maintenance Life, the elapsed operating time over which the LED light
source will maintain the percentage, p, of its initial light output e.g:
 L70 (hours): Time to 70% lumen maintenance
 L50 (hours): Time to 50% lumen maintenance
The LED life is predicted according to the Arrhenius model, the formula as following:
1. P=P0 exp(-βt)
2. β=β0 IFexp(-Ea/KTj)
Note: P0 is initial lumen; P is lumen under heat and electricity; β is recession
coefficient in a certain temperature; t is the time to electricity in a certain
temperature; β0 is constant value; Ea is activation energy; K is Boltzmann's
constant; IF is working current; Tj is junction temperature.
Firstly, we predict the LED life per 10000hours. For example, we suppose the
optical decay rate is n% in 1000hours, then:
Base on formula 1, L50 is: t=1000*ln0.5/ln(1-n%)
Base on formula 1, L30 is: t=1000*ln0.7/ln(1-n%)
So we can get:
Item Optical decay rate L50(h) L30(h)
85℃ 8% 8312.950414 4277.62127
70℃ 3% 22756.57306 11709.922
The temperature Tj (the contact surface temperature between LED and circuit board,
or ambient temperature providing the heat-sink is complete, but the junction
temperature will be 15℃ hig her than am bient tem perature in 350m A) w ill g reatly
affect the test result. We can predict the LED life under varies temperature
according to formula 2. Suppose the time t1 is the LED life under T1 temperature,
time t2 is the LED life under T2 temperature, then we can calculate the time t3 under
T3 temperature: t3=t1*exp{(ln(t2/t1)/[1/(T2+15+273)-1/(T1+15+273)] *
[1/(T3+15+273)-1/(T1+15+273)]}
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
1. System Configuration
Refer to LM-80, the LED typically exhibit very long operational life characteristics
and, depending on drive current and use conditions, can be in use for 50,000 hours
or longer.
The LED Lumen Maintenance and Life Test System include two parts of function: LED
lumen maintenance life and also measure the LED colorimetric parameters
maintenance curve such as CCT, Chromaticity and spectrum.
PS. The customer needs to prepare the PC and Printer
The full system of LEDLM-80PL includes the following items:
 LED Aging Control System with Arrhenius Software (LM-80PL): it
measure total 16 channels on the following curve: photometric VS colorimetric
VS power VS temperature VS time. The aging time can be max 10K hours. It can
calculate the life according to TM-21.
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
 Multiplex Temperature Tester (TMP-16): To measure temperature for 16
channels samples, it can communicate with PC via LM-80PL software
 Photometric & Colorimetric & Electric Parameters Measurement
System: To measure photometric, colorimetric and electric parameters for 16
channels, all the instruments can communicate with PC via LM-80PL software
 Multi-Channel Power Switch System: to control the power for the test lamp
 Lamp adapter in High and Low Temperature Chamber: design according
to customer’s request, max 16pcs.
Please note the following two items needs to prepare separately:
 High Temperature Chamber: depend on the test lamp size
 AC Power Source: depend on the test lamp power
3. Refer to the International Standard
IEC/PAS 62612 Self-ballasted LED-Lamps for General Lighting
Services-Performance Requirements
IEC/PAS 62717 LED modules for general lighting – Performance requirements
IEC/PAS 62722-2-1 Luminaire Performance –Part 2-1: Particular requirements for
LED luminaires
IES LM-80-08 Approved Method for Measuring Lumen Maintenance of LED Light
Sources
IES TM-21-11 Projecting Long Term Lumen Maintenance of LED Packages
IESNA LM-82-12 Approved Method: Characterization of LED Engines and LED Lamps
for Electrical and Photometric Properties as a Function of Temperature
ENERGY STAR® Program Requirements Product Specification Eligibility Criteria
The Next Page Is The Test Report:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342
Report No.: 201401002 Page 1 of 6 Pages
Lumen Maintenance Test Report
Client : OSRAM Lighting
Address : Jiading Shanghai
Description of the samples under test:
Sample Name : White SMD LED
Model : YL-T3528W-AA-60C
Ratings : 20mA, 6.5lm, 75(Ra), 6000K
Manufacturer : OSRAM Lighting
Sample Quantity : 6
Sample Tested Date : 2014-11-12 ~ 2014-12-12
Equipment list:
Test Equipments
Photometer Colorimter
Digital Power Meter
Power Supply
Thermometer
High Temperature Chamber
Model/SN
LMS-4000/201201002
LS2008R/201302005
LSP-500VAR/201403001
TMP-8/201403005
GDW-015A/201403002
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342
Report No.: 201401002 Page 2 of 6 Pages
Lumen Maintenance Life Prediction(Based on TM-21)
Test Condition - 55 Case Temp℃
Sample Name: White SMD LED
Model: YL-T3528W-AA-60C
Ratings: 20mA, 6.5lm, 75(Ra), 6000K
Manufacturer: OSRAM Lighting
Sample Quantity 6
Number Of Failures 0
DUT drive voltage used in the test (V/Hz) 220.1/50.02
Test duration (hours) 6000
Test duration used for projection (hour to hour) 1000 - 6000
Tested case temperature ('C) 55
α 6.081E-006
B 0.998
Calculated L70(6k) (hours) 815715
Reported L70(6k) (hours) >33000
Calculated L50(6k) (hours) 871049
Reported L50(6k) (hours) >33000
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342
Report No.: 201401002 Page 3 of 6 Pages
Lumen Maintenance Graph [%]
110.00
100.00
90.00
80.00
70.00
60.00
50.00
40.00
30.00
20.00
10.00
0 610 1220 1830 2440 3050 3660 4270 4880 5490 6100
Readout [Hours]
[Average] Normalized to 100 at 48 hours
LumenMaintenance[%]
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342
Report No.: 201401002 Page 4 of 6 Pages
Chromaticity Shift Graph [du'v']
0.0050
0.0040
0.0030
0.0020
0.0010
-0.0000
-0.0010
-0.0020
-0.0030
-0.0040
-0.0050
0 610 1220 1830 2440 3050 3660 4270 4880 5490 6100
Readout [Hours]
[Average] Reference Point at 48 hours
ChromaticityShift[du'v']
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342
Report No.: 201401002 Page 5 of 6 Pages
Lumen Maintenance Table [%]
Model : YL-T3528W-AA-60C Ratings : 20mA, 6.5lm, 75(Ra), 6000K
Actual Temperature : Ta = 55.0 , Ts = 65.0℃ ℃ Humidity : R.H. = 60%
Number Of Failures : 0 Uncertainty : 4%
Drive Voltage : U = 220.1V, Freq. = 50.02Hz
No.
1
2
3
4
5
6
Median
Average
Std. deviation
Min.
Max.
0H
100.45
99.91
99.82
100.09
100.00
99.91
99.95
100.03
0.2260
99.82
100.45
24H
100.36
100.09
100.27
100.27
100.18
100.18
100.23
100.23
0.0948
100.09
100.36
48H
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
0.0000
100.00
100.00
168H
99.46
99.28
99.65
99.54
99.50
99.15
99.48
99.43
0.1829
99.15
99.65
500H
97.21
98.01
98.31
100.27
100.20
100.32
99.25
99.05
1.3750
97.21
100.32
1000H
99.01
99.36
99.55
99.72
99.44
98.99
99.40
99.34
0.2941
98.99
99.72
2000H
98.01
98.54
98.74
98.99
98.52
98.17
98.53
98.49
0.3587
98.01
98.99
3000H
97.47
98.08
98.38
98.62
97.96
97.71
98.02
98.03
0.4215
97.47
98.62
4000H
96.75
97.63
97.92
98.16
97.50
97.25
97.56
97.53
0.4998
96.75
98.16
5000H
95.85
96.53
96.92
97.15
96.38
96.24
96.46
96.51
0.4715
95.85
97.15
6000H
95.74
96.53
96.83
97.15
96.31
96.25
96.42
96.47
0.4893
95.74
97.15
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel: +86(21)51083341
Fax: +86(21)51083342
Report No.: 201401002 Page 6 of 6 Pages
Chromaticity Shift Table [du'v']
Model : YL-T3528W-AA-60C Ratings : 20mA, 6.5lm, 75(Ra), 6000K
Actual Temperature : Ta = 55.0 , Ts = 65.0℃ ℃ Humidity : R.H. = 60%
Number Of Failures : 0
Drive Voltage : U = 220.1V, Freq. = 50.02Hz
No.
1
2
3
4
5
6
Median
Average
Std. deviation
Min.
Max.
0H
0.0001
0.0003
0.0000
0.0000
0.0000
0.0001
0.0001
0.0001
0.00012
0.0000
0.0003
24H
-0.0001
0.0000
-0.0001
-0.0001
-0.0001
0.0000
-0.0001
-0.0001
0.00007
-0.0001
0.0000
48H
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.00000
0.0000
0.0000
168H
-0.0001
0.0001
0.0000
-0.0001
0.0001
0.0000
0.0000
-0.0000
0.00013
-0.0001
0.0001
500H
0.0008
0.0014
0.0001
0.0011
0.0018
0.0004
0.0010
0.0009
0.00064
0.0001
0.0018
1000H
0.0001
0.0004
0.0001
0.0000
0.0001
0.0004
0.0001
0.0002
0.00017
0.0000
0.0004
2000H
0.0006
0.0008
0.0006
0.0006
0.0007
0.0008
0.0006
0.0007
0.00014
0.0006
0.0008
3000H
0.0007
0.0010
0.0007
0.0007
0.0010
0.0011
0.0008
0.0009
0.00019
0.0007
0.0011
4000H
0.0008
0.0011
0.0008
0.0008
0.0010
0.0013
0.0009
0.0010
0.00018
0.0008
0.0013
5000H
0.0006
0.0008
0.0007
0.0007
0.0007
0.0010
0.0007
0.0008
0.00015
0.0006
0.0010
6000H
0.0011
0.0016
0.0013
0.0011
0.0013
0.0014
0.0013
0.0013
0.00017
0.0011
0.0016

More Related Content

What's hot

Powersines presentation (lec)
Powersines presentation (lec)Powersines presentation (lec)
Powersines presentation (lec)
greenacquisition
 

What's hot (12)

Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirrorGoniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
 
SOLAR PANELS CATALOGUE
SOLAR PANELS CATALOGUE SOLAR PANELS CATALOGUE
SOLAR PANELS CATALOGUE
 
Ja solar panel 400 watt jam72 s10 mr 390 410 global-en_20190523a
Ja solar panel 400 watt jam72 s10 mr 390 410 global-en_20190523aJa solar panel 400 watt jam72 s10 mr 390 410 global-en_20190523a
Ja solar panel 400 watt jam72 s10 mr 390 410 global-en_20190523a
 
ABB Price List MCB DB
ABB Price List MCB DBABB Price List MCB DB
ABB Price List MCB DB
 
ABB Price List of Capacitors 008
ABB Price List of Capacitors 008ABB Price List of Capacitors 008
ABB Price List of Capacitors 008
 
Solon Black 230
Solon Black 230Solon Black 230
Solon Black 230
 
ABB price list 2018010
ABB price list 2018010ABB price list 2018010
ABB price list 2018010
 
ABB Price List 2019
ABB Price List 2019ABB Price List 2019
ABB Price List 2019
 
Powersines presentation (lec)
Powersines presentation (lec)Powersines presentation (lec)
Powersines presentation (lec)
 
Abb Price List 2018
Abb Price List 2018Abb Price List 2018
Abb Price List 2018
 
ABB Contactor Price List
ABB Contactor Price List ABB Contactor Price List
ABB Contactor Price List
 
IRJET- Intelligent Power Emulator
IRJET- Intelligent Power EmulatorIRJET- Intelligent Power Emulator
IRJET- Intelligent Power Emulator
 

Similar to Led lumen-maintenance-and-life-test-system

Similar to Led lumen-maintenance-and-life-test-system (20)

Thermal resistance-spectroradiometer-system-for-led
Thermal resistance-spectroradiometer-system-for-ledThermal resistance-spectroradiometer-system-for-led
Thermal resistance-spectroradiometer-system-for-led
 
Thermal resistance-spectroradiometer-system-for-led
Thermal resistance-spectroradiometer-system-for-ledThermal resistance-spectroradiometer-system-for-led
Thermal resistance-spectroradiometer-system-for-led
 
Thermal resistance spectroradiometer system for led
Thermal resistance spectroradiometer system for ledThermal resistance spectroradiometer system for led
Thermal resistance spectroradiometer system for led
 
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000visCcd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
 
Electronic ballast-tester
Electronic ballast-testerElectronic ballast-tester
Electronic ballast-tester
 
Electronic ballast-tester
Electronic ballast-testerElectronic ballast-tester
Electronic ballast-tester
 
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000visCcd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
 
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000visCcd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
Ccd spectroradiometer-integrating-sphere-compact-system-for-led-7000vis
 
5 FINAL PROJECT REPORT
5 FINAL PROJECT REPORT5 FINAL PROJECT REPORT
5 FINAL PROJECT REPORT
 
Led driver-aging-rack
Led driver-aging-rackLed driver-aging-rack
Led driver-aging-rack
 
Led driver-aging-rack
Led driver-aging-rackLed driver-aging-rack
Led driver-aging-rack
 
Integrating sphere-and-ccd-spectroradiometer-system
Integrating sphere-and-ccd-spectroradiometer-systemIntegrating sphere-and-ccd-spectroradiometer-system
Integrating sphere-and-ccd-spectroradiometer-system
 
Integrating sphere-and-ccd-spectroradiometer-system
Integrating sphere-and-ccd-spectroradiometer-systemIntegrating sphere-and-ccd-spectroradiometer-system
Integrating sphere-and-ccd-spectroradiometer-system
 
Rohs testing
Rohs testingRohs testing
Rohs testing
 
Rohs testing
Rohs testingRohs testing
Rohs testing
 
INTELLIGENT HELMET FOR COAL MINERS
INTELLIGENT HELMET FOR COAL MINERSINTELLIGENT HELMET FOR COAL MINERS
INTELLIGENT HELMET FOR COAL MINERS
 
EDX-2 Energy Dispersive X-ray Fluorescence Spectrometer
EDX-2 Energy Dispersive X-ray Fluorescence SpectrometerEDX-2 Energy Dispersive X-ray Fluorescence Spectrometer
EDX-2 Energy Dispersive X-ray Fluorescence Spectrometer
 
Flexing test-apparatus
Flexing test-apparatusFlexing test-apparatus
Flexing test-apparatus
 
Led driver-online-tester
Led driver-online-testerLed driver-online-tester
Led driver-online-tester
 
Led driver-online-tester
Led driver-online-testerLed driver-online-tester
Led driver-online-tester
 

More from 世满 江

More from 世满 江 (20)

Xenon lamp-aging-test-chamber
Xenon lamp-aging-test-chamberXenon lamp-aging-test-chamber
Xenon lamp-aging-test-chamber
 
Water pressure-test-apparatus
Water pressure-test-apparatusWater pressure-test-apparatus
Water pressure-test-apparatus
 
Uv aging-test-chamber
Uv aging-test-chamberUv aging-test-chamber
Uv aging-test-chamber
 
Ul water-spray-test-device
Ul water-spray-test-deviceUl water-spray-test-device
Ul water-spray-test-device
 
Test corners
Test cornersTest corners
Test corners
 
Spectrophotometer
SpectrophotometerSpectrophotometer
Spectrophotometer
 
Spectral colorimeter
Spectral colorimeterSpectral colorimeter
Spectral colorimeter
 
Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
 
Portable ccd-spectroradiometer
Portable ccd-spectroradiometerPortable ccd-spectroradiometer
Portable ccd-spectroradiometer
 
Phosphor relative-brightness-tester 1
Phosphor relative-brightness-tester 1Phosphor relative-brightness-tester 1
Phosphor relative-brightness-tester 1
 
Oxygen bomb
Oxygen bombOxygen bomb
Oxygen bomb
 
Optical radiation-safety-test-system
Optical radiation-safety-test-systemOptical radiation-safety-test-system
Optical radiation-safety-test-system
 
Near field-type-c-goniophotometer
Near field-type-c-goniophotometerNear field-type-c-goniophotometer
Near field-type-c-goniophotometer
 
Moving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccdMoving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccd
 
Moving detector-goniospectroradiometer
Moving detector-goniospectroradiometerMoving detector-goniospectroradiometer
Moving detector-goniospectroradiometer
 
Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000
 
Moving detector-goniophotometer
Moving detector-goniophotometerMoving detector-goniophotometer
Moving detector-goniophotometer
 
Lpce 2 lms-9000-buv_ uv-lamp-test-system
Lpce 2 lms-9000-buv_ uv-lamp-test-systemLpce 2 lms-9000-buv_ uv-lamp-test-system
Lpce 2 lms-9000-buv_ uv-lamp-test-system
 
Led power-driver-tester
Led power-driver-testerLed power-driver-tester
Led power-driver-tester
 
Led lumen-maintenance-and-life-test-system
Led lumen-maintenance-and-life-test-systemLed lumen-maintenance-and-life-test-system
Led lumen-maintenance-and-life-test-system
 

Recently uploaded

EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
Earley Information Science
 

Recently uploaded (20)

Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 

Led lumen-maintenance-and-life-test-system

  • 1. Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Leader in Lighting & Electrical Test Instruments Rev. 10/18/2019 LED Lumen Maintenance and Life Test System (LEDLM-80PL)
  • 2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 1 - System Principle Rated Lumen Maintenance Life, the elapsed operating time over which the LED light source will maintain the percentage, p, of its initial light output e.g:  L70 (hours): Time to 70% lumen maintenance  L50 (hours): Time to 50% lumen maintenance The LED life is predicted according to the Arrhenius model, the formula as following: 1. P=P0 exp(-βt) 2. β=β0 IFexp(-Ea/KTj) Note: P0 is initial lumen; P is lumen under heat and electricity; β is recession coefficient in a certain temperature; t is the time to electricity in a certain temperature; β0 is constant value; Ea is activation energy; K is Boltzmann's constant; IF is working current; Tj is junction temperature. Firstly, we predict the LED life per 10000hours. For example, we suppose the optical decay rate is n% in 1000hours, then: Base on formula 1, L50 is: t=1000*ln0.5/ln(1-n%) Base on formula 1, L30 is: t=1000*ln0.7/ln(1-n%) So we can get: Item Optical decay rate L50(h) L30(h) 85℃ 8% 8312.950414 4277.62127 70℃ 3% 22756.57306 11709.922 The temperature Tj (the contact surface temperature between LED and circuit board, or ambient temperature providing the heat-sink is complete, but the junction temperature will be 15℃ hig her than am bient tem perature in 350m A) w ill g reatly affect the test result. We can predict the LED life under varies temperature according to formula 2. Suppose the time t1 is the LED life under T1 temperature, time t2 is the LED life under T2 temperature, then we can calculate the time t3 under T3 temperature: t3=t1*exp{(ln(t2/t1)/[1/(T2+15+273)-1/(T1+15+273)] * [1/(T3+15+273)-1/(T1+15+273)]}
  • 3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 2 - 1. System Configuration Refer to LM-80, the LED typically exhibit very long operational life characteristics and, depending on drive current and use conditions, can be in use for 50,000 hours or longer. The LED Lumen Maintenance and Life Test System include two parts of function: LED lumen maintenance life and also measure the LED colorimetric parameters maintenance curve such as CCT, Chromaticity and spectrum. PS. The customer needs to prepare the PC and Printer The full system of LEDLM-80PL includes the following items:  LED Aging Control System with Arrhenius Software (LM-80PL): it measure total 16 channels on the following curve: photometric VS colorimetric VS power VS temperature VS time. The aging time can be max 10K hours. It can calculate the life according to TM-21.
  • 4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 3 -  Multiplex Temperature Tester (TMP-16): To measure temperature for 16 channels samples, it can communicate with PC via LM-80PL software  Photometric & Colorimetric & Electric Parameters Measurement System: To measure photometric, colorimetric and electric parameters for 16 channels, all the instruments can communicate with PC via LM-80PL software  Multi-Channel Power Switch System: to control the power for the test lamp  Lamp adapter in High and Low Temperature Chamber: design according to customer’s request, max 16pcs. Please note the following two items needs to prepare separately:  High Temperature Chamber: depend on the test lamp size  AC Power Source: depend on the test lamp power 3. Refer to the International Standard IEC/PAS 62612 Self-ballasted LED-Lamps for General Lighting Services-Performance Requirements IEC/PAS 62717 LED modules for general lighting – Performance requirements IEC/PAS 62722-2-1 Luminaire Performance –Part 2-1: Particular requirements for LED luminaires IES LM-80-08 Approved Method for Measuring Lumen Maintenance of LED Light Sources IES TM-21-11 Projecting Long Term Lumen Maintenance of LED Packages IESNA LM-82-12 Approved Method: Characterization of LED Engines and LED Lamps for Electrical and Photometric Properties as a Function of Temperature ENERGY STAR® Program Requirements Product Specification Eligibility Criteria The Next Page Is The Test Report:
  • 5. Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: 201401002 Page 1 of 6 Pages Lumen Maintenance Test Report Client : OSRAM Lighting Address : Jiading Shanghai Description of the samples under test: Sample Name : White SMD LED Model : YL-T3528W-AA-60C Ratings : 20mA, 6.5lm, 75(Ra), 6000K Manufacturer : OSRAM Lighting Sample Quantity : 6 Sample Tested Date : 2014-11-12 ~ 2014-12-12 Equipment list: Test Equipments Photometer Colorimter Digital Power Meter Power Supply Thermometer High Temperature Chamber Model/SN LMS-4000/201201002 LS2008R/201302005 LSP-500VAR/201403001 TMP-8/201403005 GDW-015A/201403002
  • 6. Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: 201401002 Page 2 of 6 Pages Lumen Maintenance Life Prediction(Based on TM-21) Test Condition - 55 Case Temp℃ Sample Name: White SMD LED Model: YL-T3528W-AA-60C Ratings: 20mA, 6.5lm, 75(Ra), 6000K Manufacturer: OSRAM Lighting Sample Quantity 6 Number Of Failures 0 DUT drive voltage used in the test (V/Hz) 220.1/50.02 Test duration (hours) 6000 Test duration used for projection (hour to hour) 1000 - 6000 Tested case temperature ('C) 55 α 6.081E-006 B 0.998 Calculated L70(6k) (hours) 815715 Reported L70(6k) (hours) >33000 Calculated L50(6k) (hours) 871049 Reported L50(6k) (hours) >33000
  • 7. Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: 201401002 Page 3 of 6 Pages Lumen Maintenance Graph [%] 110.00 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0 610 1220 1830 2440 3050 3660 4270 4880 5490 6100 Readout [Hours] [Average] Normalized to 100 at 48 hours LumenMaintenance[%]
  • 8. Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: 201401002 Page 4 of 6 Pages Chromaticity Shift Graph [du'v'] 0.0050 0.0040 0.0030 0.0020 0.0010 -0.0000 -0.0010 -0.0020 -0.0030 -0.0040 -0.0050 0 610 1220 1830 2440 3050 3660 4270 4880 5490 6100 Readout [Hours] [Average] Reference Point at 48 hours ChromaticityShift[du'v']
  • 9. Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: 201401002 Page 5 of 6 Pages Lumen Maintenance Table [%] Model : YL-T3528W-AA-60C Ratings : 20mA, 6.5lm, 75(Ra), 6000K Actual Temperature : Ta = 55.0 , Ts = 65.0℃ ℃ Humidity : R.H. = 60% Number Of Failures : 0 Uncertainty : 4% Drive Voltage : U = 220.1V, Freq. = 50.02Hz No. 1 2 3 4 5 6 Median Average Std. deviation Min. Max. 0H 100.45 99.91 99.82 100.09 100.00 99.91 99.95 100.03 0.2260 99.82 100.45 24H 100.36 100.09 100.27 100.27 100.18 100.18 100.23 100.23 0.0948 100.09 100.36 48H 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 0.0000 100.00 100.00 168H 99.46 99.28 99.65 99.54 99.50 99.15 99.48 99.43 0.1829 99.15 99.65 500H 97.21 98.01 98.31 100.27 100.20 100.32 99.25 99.05 1.3750 97.21 100.32 1000H 99.01 99.36 99.55 99.72 99.44 98.99 99.40 99.34 0.2941 98.99 99.72 2000H 98.01 98.54 98.74 98.99 98.52 98.17 98.53 98.49 0.3587 98.01 98.99 3000H 97.47 98.08 98.38 98.62 97.96 97.71 98.02 98.03 0.4215 97.47 98.62 4000H 96.75 97.63 97.92 98.16 97.50 97.25 97.56 97.53 0.4998 96.75 98.16 5000H 95.85 96.53 96.92 97.15 96.38 96.24 96.46 96.51 0.4715 95.85 97.15 6000H 95.74 96.53 96.83 97.15 96.31 96.25 96.42 96.47 0.4893 95.74 97.15
  • 10. Lisun Electronics Inc. http://www.Lisungroup.com Tel: +86(21)51083341 Fax: +86(21)51083342 Report No.: 201401002 Page 6 of 6 Pages Chromaticity Shift Table [du'v'] Model : YL-T3528W-AA-60C Ratings : 20mA, 6.5lm, 75(Ra), 6000K Actual Temperature : Ta = 55.0 , Ts = 65.0℃ ℃ Humidity : R.H. = 60% Number Of Failures : 0 Drive Voltage : U = 220.1V, Freq. = 50.02Hz No. 1 2 3 4 5 6 Median Average Std. deviation Min. Max. 0H 0.0001 0.0003 0.0000 0.0000 0.0000 0.0001 0.0001 0.0001 0.00012 0.0000 0.0003 24H -0.0001 0.0000 -0.0001 -0.0001 -0.0001 0.0000 -0.0001 -0.0001 0.00007 -0.0001 0.0000 48H 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00000 0.0000 0.0000 168H -0.0001 0.0001 0.0000 -0.0001 0.0001 0.0000 0.0000 -0.0000 0.00013 -0.0001 0.0001 500H 0.0008 0.0014 0.0001 0.0011 0.0018 0.0004 0.0010 0.0009 0.00064 0.0001 0.0018 1000H 0.0001 0.0004 0.0001 0.0000 0.0001 0.0004 0.0001 0.0002 0.00017 0.0000 0.0004 2000H 0.0006 0.0008 0.0006 0.0006 0.0007 0.0008 0.0006 0.0007 0.00014 0.0006 0.0008 3000H 0.0007 0.0010 0.0007 0.0007 0.0010 0.0011 0.0008 0.0009 0.00019 0.0007 0.0011 4000H 0.0008 0.0011 0.0008 0.0008 0.0010 0.0013 0.0009 0.0010 0.00018 0.0008 0.0013 5000H 0.0006 0.0008 0.0007 0.0007 0.0007 0.0010 0.0007 0.0008 0.00015 0.0006 0.0010 6000H 0.0011 0.0016 0.0013 0.0011 0.0013 0.0014 0.0013 0.0013 0.00017 0.0011 0.0016