SlideShare a Scribd company logo
1 of 11
Download to read offline
SMART OMNI
Omnidirectional sound source
www.ntek.it
This paper shows the results of the measurements done to assess the compliance of the sound
sources with the requirements stated in ISO Standards 3744 and 3382 about sound power and
directivity of sound sources.
The entire measurement was conducted following the guidelines provided by the International
Standard Organisation about this kind of tests, in particular the procedure is compliant with
ISO Standard 17025.
Table of contents
Tested Source ........................................................................................	 3
Measuring environment ......................................................................	 4
Measuring equipment ..........................................................................	 6
Results ...................................................................................................	 7
Sound power .................................................................................	 7
Sound pressure .............................................................................	 8
Directivity ......................................................................................	 9
All information subject to change without notice
Tested Source
Model
SMART OMNI
Omnidirectional
sound source
Diameter
(mm)
280
Weight (Kg)
9.5
Impedence
(ohm)
3 + 3
Number
of speakers
12
3
The sound source was fed with Pink Noise using an
AMG Mini Digital Amplifier.
During the measurement the sound source was installed
on a rotating device (MB01) free to move on its central
axis for 360° (see Fig. 1).
Fig. 1	 Photos of measured source and measurement conditions
All information subject to change without notice
Measuring environment
In Figure 2 is reported a simple drawing of the anechoic chamber used for this measurement.
The height of the chamber is 2.63 m.
3530
3170
360
3450
1500
3780
Mic 2
Mic 1
Sound Source
5
0
0
Fig. 2	 Mic placement – Mic 1 is for sound power measurement, while Mic 2 is for sound pressure one. Distances in mm
Type Temperature Humidity Pressure
Hemi-Anechoic
Chamber
23 ± 1 ° C 30 ± 15 % 994 ± 10 hPa
4
All information subject to change without notice
K1 and K2 correction factor are negligible because of the environment of the measurement
(hemi-anechoic chamber).
The chosen procedure was the one of a high machine with a narrow base due to the assembly of the
sound source (see Source Tested for a reference).
The next tables show the values of L1, L2, L3 and D for this speaker and, hence, the values of A, B, C and S.
L1 (m) L2 (m) L3 (m) D (m)
0.28 0.28 1.67 0.5
A (m) B (m) C (m) S (m2)
0.64 0.64 2.17 12.75
Fig. 3	 Representation of measurement procedure as indicated in ISO 3744
5
All information subject to change without notice
Measuring equipment
Device Model Manufacturer Serial number
Sound level meter
Microphone
Preamplifier
Sound Calibrator
Rotating device
NL-52
UC59
NH-25
NC-75
MB-01
Rion
Rion
Rion
Rion
Ntek
00342833
12852
10461
34891821
Ntek Calibration
Lab test tool
The microphone used for the measurement was equipped with a windscreen.
6
To measure the sound source the Rotating device was used in order to “sample” the source every 5° as
stated within the ISO Standard.
The microphone was left in the same position for the entire duration of the measurement.
The data aquired was, then, processed with the help of a dedicated software that, with a proper algorithm,
led to the results indicated in Results section.
All information subject to change without notice
Results
In this section are reported the results of the measurements about the sound power of the source and
its directivity.
Lw = 127.0 dBA
Fig. 4	 Sound Power Level Spectrum - 1/3 oct
Sound power
0,0
20,0
40,0
60,0
80,0
100,0
120,0
140,0
16
20
25
32
40
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
6300
8000
10000
dBA
Frequency (Hz)
7
-20,0
0,0
20,0
40,0
60,0
80,0
100,0
120,0
16
20
25
32
40
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
6300
8000
10000
dBA
Frequency (Hz)
0,0
20,0
40,0
60,0
80,0
100,0
120,0
16
20
25
32
40
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
6300
8000
10000
dBA
Frequency (Hz)
All information subject to change without notice
Lp: 116 dBA
Fig. 6	 A Weighted Sound Pressure Level – 1/3 octave
Lp linear: 121 dB
Fig. 5	 Linear Sound Pressure Level – 1/3 octave
Sound pressure
8
All information subject to change without notice
9
Fig. 8	 Directivity according to ISO 16283. Upper and lower curves are the ISO 16283 tolerances
-10
-5
0
5
10
100 1000
Directivity
Index
Frequency (Hz)
Fig. 7	 Directional response – 1/1 octave
Directivity
0,0
20,0
40,0
60,0
80,0
100,0
120,0
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330° 31,5 Hz
63 Hz
125 Hz
250 Hz
500 Hz
1 KHz
2 KHz
4 KHz
8 KHz
16 KHz
20 KHz
All information subject to change without notice
Fig. 9	 Directivity according to ISO 3382. Upper and lower curves are the ISO 3382 tolerances
-10
-5
0
5
10
100 1000
Directivity
Index
Frequency (Hz)
10
Company identity
Ntek is specialized in products and services
for noise and vibration measurement and control,
in all applicable acoustic fields.
The company has been able to improve in designing,
developing and producing solutions that mix
simplicity, portability and user-friendly products
with excellent quality.
Ntek main goal is to supply a qualified service with
a complete range of products delivered on time
in order to guarantee its customers the chance
to focus on their business.
To keep this promise we have strongly invested
in innovation and production process with
monitoring procedures certified by independent
primary authority.
OUR VISION
We believe that acoustics is the basis of wellness
and improvement of life quality.
It’s for this reason that we develop,
innovate and produce equipment inspired
to this philosophy.
HOW WE WORK
Ntek can ensure a high level of service,
thanks to modern processes and new laboratories,
completely equipped for different operations
of design, production, measurement,
check and control.
INTERNAL LOGISTICS AND STOCK
With its new operative location of 500 m2
and
its internal stock, Ntek guarantees available products
in a short time according to customers’ needs.
Today we can handle an order in 48 hours
compared with a standard delivery of 45/60 days.
The new location is structured to be flexible
with logistics activities and in answering efficiently
to productive needs of our customers.
SUSTAINABILITY
Green company, environmentally friendly,
aimed to a continuous improvement
of quality and safety in industrial processes.
Ntek S.r.l.
Via Gabrielli 18
10077 San Maurizio Canavese (TO)
ITALY
www.ntek.it
info@ntek.it
+39 011 40 53 600

More Related Content

What's hot

Pipe End Dimensioning Service
Pipe End Dimensioning ServicePipe End Dimensioning Service
Pipe End Dimensioning Service
denisesmiles
 

What's hot (11)

Tpm pro inglese
Tpm pro ingleseTpm pro inglese
Tpm pro inglese
 
Norsonic product-catalogue-2017-web
Norsonic product-catalogue-2017-webNorsonic product-catalogue-2017-web
Norsonic product-catalogue-2017-web
 
Curd watch presentation
Curd watch presentationCurd watch presentation
Curd watch presentation
 
Linear instruments
Linear instrumentsLinear instruments
Linear instruments
 
Datasheet Fluke 922. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 922. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 922. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 922. Hubungi PT. Siwali Swantika 021-45850618
 
RUGOSIDAD Y CONTORNO PORTAFOLIO 2015
RUGOSIDAD Y CONTORNO PORTAFOLIO 2015RUGOSIDAD Y CONTORNO PORTAFOLIO 2015
RUGOSIDAD Y CONTORNO PORTAFOLIO 2015
 
Polyester Moisture Meter by ACMAS Technologies Pvt Ltd.
Polyester Moisture Meter by ACMAS Technologies Pvt Ltd.Polyester Moisture Meter by ACMAS Technologies Pvt Ltd.
Polyester Moisture Meter by ACMAS Technologies Pvt Ltd.
 
Ideal instrument
Ideal instrumentIdeal instrument
Ideal instrument
 
Pipe End Dimensioning Service
Pipe End Dimensioning ServicePipe End Dimensioning Service
Pipe End Dimensioning Service
 
OPTICLINE C200 C1000 BY JENOPTIK
OPTICLINE C200 C1000 BY JENOPTIKOPTICLINE C200 C1000 BY JENOPTIK
OPTICLINE C200 C1000 BY JENOPTIK
 
Opticline 2016 by Jenoptik
Opticline 2016 by JenoptikOpticline 2016 by Jenoptik
Opticline 2016 by Jenoptik
 

Similar to NTEK Omni-directional Source Source

2015_Mead_Patrick_Design_Portfolio_PCB
2015_Mead_Patrick_Design_Portfolio_PCB2015_Mead_Patrick_Design_Portfolio_PCB
2015_Mead_Patrick_Design_Portfolio_PCB
Patrick Mead
 
Pavel_Solomein_Final_Project_2015
Pavel_Solomein_Final_Project_2015Pavel_Solomein_Final_Project_2015
Pavel_Solomein_Final_Project_2015
Pavel Solomein
 
Vanguard-Equipment-Brochure
Vanguard-Equipment-BrochureVanguard-Equipment-Brochure
Vanguard-Equipment-Brochure
Donna M. Pepe
 
Labguard 3D Technical brochure
Labguard 3D Technical brochureLabguard 3D Technical brochure
Labguard 3D Technical brochure
Nestor Martinez
 
rae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposesrae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposes
134483
 

Similar to NTEK Omni-directional Source Source (20)

Rt60 | Dewesoft
Rt60 | DewesoftRt60 | Dewesoft
Rt60 | Dewesoft
 
Semtech NO NO2 Analyser
Semtech NO NO2 AnalyserSemtech NO NO2 Analyser
Semtech NO NO2 Analyser
 
EBSO: CATALOGO CONTROL COMPANY - TERMOMETROS-HIGROMETROS
EBSO: CATALOGO CONTROL COMPANY - TERMOMETROS-HIGROMETROSEBSO: CATALOGO CONTROL COMPANY - TERMOMETROS-HIGROMETROS
EBSO: CATALOGO CONTROL COMPANY - TERMOMETROS-HIGROMETROS
 
Rion general(full) catalog_0810-19_denkei
Rion general(full) catalog_0810-19_denkeiRion general(full) catalog_0810-19_denkei
Rion general(full) catalog_0810-19_denkei
 
2015_Mead_Patrick_Design_Portfolio_PCB
2015_Mead_Patrick_Design_Portfolio_PCB2015_Mead_Patrick_Design_Portfolio_PCB
2015_Mead_Patrick_Design_Portfolio_PCB
 
A novel approach to record sound
A novel approach to record soundA novel approach to record sound
A novel approach to record sound
 
智诚创科 挪声尼 2020 产品目录
智诚创科 挪声尼 2020 产品目录智诚创科 挪声尼 2020 产品目录
智诚创科 挪声尼 2020 产品目录
 
Pavel_Solomein_Final_Project_2015
Pavel_Solomein_Final_Project_2015Pavel_Solomein_Final_Project_2015
Pavel_Solomein_Final_Project_2015
 
Toa Audio Catalog 2019
Toa Audio Catalog 2019Toa Audio Catalog 2019
Toa Audio Catalog 2019
 
Noiseken electromagnetic field visualization system - denkei
Noiseken electromagnetic field visualization system - denkeiNoiseken electromagnetic field visualization system - denkei
Noiseken electromagnetic field visualization system - denkei
 
Vanguard-Equipment-Brochure
Vanguard-Equipment-BrochureVanguard-Equipment-Brochure
Vanguard-Equipment-Brochure
 
Micro e systems_catalog
Micro e systems_catalogMicro e systems_catalog
Micro e systems_catalog
 
Labguard 3D Technical brochure
Labguard 3D Technical brochureLabguard 3D Technical brochure
Labguard 3D Technical brochure
 
Iec 62676 5 standardized spezification of image quality
Iec 62676 5 standardized spezification of image qualityIec 62676 5 standardized spezification of image quality
Iec 62676 5 standardized spezification of image quality
 
NVH Presentation
NVH PresentationNVH Presentation
NVH Presentation
 
Solid-State Spectrometer
Solid-State SpectrometerSolid-State Spectrometer
Solid-State Spectrometer
 
Ultrasonic pulse echo - pundit PL-200 PE
Ultrasonic pulse echo - pundit PL-200 PEUltrasonic pulse echo - pundit PL-200 PE
Ultrasonic pulse echo - pundit PL-200 PE
 
Bridge stability monitoring using RH sensors controlled by labview software
Bridge stability monitoring using RH sensors controlled by labview softwareBridge stability monitoring using RH sensors controlled by labview software
Bridge stability monitoring using RH sensors controlled by labview software
 
IoT BASED REAL TIME AIR AND NOISE POLLUTION ALERT SYSTEM FOR ASTHMA AND ANGIN...
IoT BASED REAL TIME AIR AND NOISE POLLUTION ALERT SYSTEM FOR ASTHMA AND ANGIN...IoT BASED REAL TIME AIR AND NOISE POLLUTION ALERT SYSTEM FOR ASTHMA AND ANGIN...
IoT BASED REAL TIME AIR AND NOISE POLLUTION ALERT SYSTEM FOR ASTHMA AND ANGIN...
 
rae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposesrae_mic2_sensors_and_signals for study purposes
rae_mic2_sensors_and_signals for study purposes
 

Recently uploaded

Hyatt driving innovation and exceptional customer experiences with FIDO passw...
Hyatt driving innovation and exceptional customer experiences with FIDO passw...Hyatt driving innovation and exceptional customer experiences with FIDO passw...
Hyatt driving innovation and exceptional customer experiences with FIDO passw...
FIDO Alliance
 
Tales from a Passkey Provider Progress from Awareness to Implementation.pptx
Tales from a Passkey Provider  Progress from Awareness to Implementation.pptxTales from a Passkey Provider  Progress from Awareness to Implementation.pptx
Tales from a Passkey Provider Progress from Awareness to Implementation.pptx
FIDO Alliance
 

Recently uploaded (20)

Simplifying Mobile A11y Presentation.pptx
Simplifying Mobile A11y Presentation.pptxSimplifying Mobile A11y Presentation.pptx
Simplifying Mobile A11y Presentation.pptx
 
AI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by AnitarajAI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by Anitaraj
 
Observability Concepts EVERY Developer Should Know (DevOpsDays Seattle)
Observability Concepts EVERY Developer Should Know (DevOpsDays Seattle)Observability Concepts EVERY Developer Should Know (DevOpsDays Seattle)
Observability Concepts EVERY Developer Should Know (DevOpsDays Seattle)
 
Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...
Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...
Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...
 
The Ultimate Prompt Engineering Guide for Generative AI: Get the Most Out of ...
The Ultimate Prompt Engineering Guide for Generative AI: Get the Most Out of ...The Ultimate Prompt Engineering Guide for Generative AI: Get the Most Out of ...
The Ultimate Prompt Engineering Guide for Generative AI: Get the Most Out of ...
 
2024 May Patch Tuesday
2024 May Patch Tuesday2024 May Patch Tuesday
2024 May Patch Tuesday
 
Event-Driven Architecture Masterclass: Integrating Distributed Data Stores Ac...
Event-Driven Architecture Masterclass: Integrating Distributed Data Stores Ac...Event-Driven Architecture Masterclass: Integrating Distributed Data Stores Ac...
Event-Driven Architecture Masterclass: Integrating Distributed Data Stores Ac...
 
Continuing Bonds Through AI: A Hermeneutic Reflection on Thanabots
Continuing Bonds Through AI: A Hermeneutic Reflection on ThanabotsContinuing Bonds Through AI: A Hermeneutic Reflection on Thanabots
Continuing Bonds Through AI: A Hermeneutic Reflection on Thanabots
 
How to Check GPS Location with a Live Tracker in Pakistan
How to Check GPS Location with a Live Tracker in PakistanHow to Check GPS Location with a Live Tracker in Pakistan
How to Check GPS Location with a Live Tracker in Pakistan
 
State of the Smart Building Startup Landscape 2024!
State of the Smart Building Startup Landscape 2024!State of the Smart Building Startup Landscape 2024!
State of the Smart Building Startup Landscape 2024!
 
Hyatt driving innovation and exceptional customer experiences with FIDO passw...
Hyatt driving innovation and exceptional customer experiences with FIDO passw...Hyatt driving innovation and exceptional customer experiences with FIDO passw...
Hyatt driving innovation and exceptional customer experiences with FIDO passw...
 
Top 10 CodeIgniter Development Companies
Top 10 CodeIgniter Development CompaniesTop 10 CodeIgniter Development Companies
Top 10 CodeIgniter Development Companies
 
How to Check CNIC Information Online with Pakdata cf
How to Check CNIC Information Online with Pakdata cfHow to Check CNIC Information Online with Pakdata cf
How to Check CNIC Information Online with Pakdata cf
 
How we scaled to 80K users by doing nothing!.pdf
How we scaled to 80K users by doing nothing!.pdfHow we scaled to 80K users by doing nothing!.pdf
How we scaled to 80K users by doing nothing!.pdf
 
JohnPollard-hybrid-app-RailsConf2024.pptx
JohnPollard-hybrid-app-RailsConf2024.pptxJohnPollard-hybrid-app-RailsConf2024.pptx
JohnPollard-hybrid-app-RailsConf2024.pptx
 
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
 
Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...
Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...
Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...
 
Tales from a Passkey Provider Progress from Awareness to Implementation.pptx
Tales from a Passkey Provider  Progress from Awareness to Implementation.pptxTales from a Passkey Provider  Progress from Awareness to Implementation.pptx
Tales from a Passkey Provider Progress from Awareness to Implementation.pptx
 
Cyber Insurance - RalphGilot - Embry-Riddle Aeronautical University.pptx
Cyber Insurance - RalphGilot - Embry-Riddle Aeronautical University.pptxCyber Insurance - RalphGilot - Embry-Riddle Aeronautical University.pptx
Cyber Insurance - RalphGilot - Embry-Riddle Aeronautical University.pptx
 
(Explainable) Data-Centric AI: what are you explaininhg, and to whom?
(Explainable) Data-Centric AI: what are you explaininhg, and to whom?(Explainable) Data-Centric AI: what are you explaininhg, and to whom?
(Explainable) Data-Centric AI: what are you explaininhg, and to whom?
 

NTEK Omni-directional Source Source

  • 1. SMART OMNI Omnidirectional sound source www.ntek.it
  • 2. This paper shows the results of the measurements done to assess the compliance of the sound sources with the requirements stated in ISO Standards 3744 and 3382 about sound power and directivity of sound sources. The entire measurement was conducted following the guidelines provided by the International Standard Organisation about this kind of tests, in particular the procedure is compliant with ISO Standard 17025. Table of contents Tested Source ........................................................................................ 3 Measuring environment ...................................................................... 4 Measuring equipment .......................................................................... 6 Results ................................................................................................... 7 Sound power ................................................................................. 7 Sound pressure ............................................................................. 8 Directivity ...................................................................................... 9
  • 3. All information subject to change without notice Tested Source Model SMART OMNI Omnidirectional sound source Diameter (mm) 280 Weight (Kg) 9.5 Impedence (ohm) 3 + 3 Number of speakers 12 3 The sound source was fed with Pink Noise using an AMG Mini Digital Amplifier. During the measurement the sound source was installed on a rotating device (MB01) free to move on its central axis for 360° (see Fig. 1). Fig. 1 Photos of measured source and measurement conditions
  • 4. All information subject to change without notice Measuring environment In Figure 2 is reported a simple drawing of the anechoic chamber used for this measurement. The height of the chamber is 2.63 m. 3530 3170 360 3450 1500 3780 Mic 2 Mic 1 Sound Source 5 0 0 Fig. 2 Mic placement – Mic 1 is for sound power measurement, while Mic 2 is for sound pressure one. Distances in mm Type Temperature Humidity Pressure Hemi-Anechoic Chamber 23 ± 1 ° C 30 ± 15 % 994 ± 10 hPa 4
  • 5. All information subject to change without notice K1 and K2 correction factor are negligible because of the environment of the measurement (hemi-anechoic chamber). The chosen procedure was the one of a high machine with a narrow base due to the assembly of the sound source (see Source Tested for a reference). The next tables show the values of L1, L2, L3 and D for this speaker and, hence, the values of A, B, C and S. L1 (m) L2 (m) L3 (m) D (m) 0.28 0.28 1.67 0.5 A (m) B (m) C (m) S (m2) 0.64 0.64 2.17 12.75 Fig. 3 Representation of measurement procedure as indicated in ISO 3744 5
  • 6. All information subject to change without notice Measuring equipment Device Model Manufacturer Serial number Sound level meter Microphone Preamplifier Sound Calibrator Rotating device NL-52 UC59 NH-25 NC-75 MB-01 Rion Rion Rion Rion Ntek 00342833 12852 10461 34891821 Ntek Calibration Lab test tool The microphone used for the measurement was equipped with a windscreen. 6 To measure the sound source the Rotating device was used in order to “sample” the source every 5° as stated within the ISO Standard. The microphone was left in the same position for the entire duration of the measurement. The data aquired was, then, processed with the help of a dedicated software that, with a proper algorithm, led to the results indicated in Results section.
  • 7. All information subject to change without notice Results In this section are reported the results of the measurements about the sound power of the source and its directivity. Lw = 127.0 dBA Fig. 4 Sound Power Level Spectrum - 1/3 oct Sound power 0,0 20,0 40,0 60,0 80,0 100,0 120,0 140,0 16 20 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 dBA Frequency (Hz) 7
  • 9. All information subject to change without notice 9 Fig. 8 Directivity according to ISO 16283. Upper and lower curves are the ISO 16283 tolerances -10 -5 0 5 10 100 1000 Directivity Index Frequency (Hz) Fig. 7 Directional response – 1/1 octave Directivity 0,0 20,0 40,0 60,0 80,0 100,0 120,0 0° 30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° 31,5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 KHz 2 KHz 4 KHz 8 KHz 16 KHz 20 KHz
  • 10. All information subject to change without notice Fig. 9 Directivity according to ISO 3382. Upper and lower curves are the ISO 3382 tolerances -10 -5 0 5 10 100 1000 Directivity Index Frequency (Hz) 10
  • 11. Company identity Ntek is specialized in products and services for noise and vibration measurement and control, in all applicable acoustic fields. The company has been able to improve in designing, developing and producing solutions that mix simplicity, portability and user-friendly products with excellent quality. Ntek main goal is to supply a qualified service with a complete range of products delivered on time in order to guarantee its customers the chance to focus on their business. To keep this promise we have strongly invested in innovation and production process with monitoring procedures certified by independent primary authority. OUR VISION We believe that acoustics is the basis of wellness and improvement of life quality. It’s for this reason that we develop, innovate and produce equipment inspired to this philosophy. HOW WE WORK Ntek can ensure a high level of service, thanks to modern processes and new laboratories, completely equipped for different operations of design, production, measurement, check and control. INTERNAL LOGISTICS AND STOCK With its new operative location of 500 m2 and its internal stock, Ntek guarantees available products in a short time according to customers’ needs. Today we can handle an order in 48 hours compared with a standard delivery of 45/60 days. The new location is structured to be flexible with logistics activities and in answering efficiently to productive needs of our customers. SUSTAINABILITY Green company, environmentally friendly, aimed to a continuous improvement of quality and safety in industrial processes. Ntek S.r.l. Via Gabrielli 18 10077 San Maurizio Canavese (TO) ITALY www.ntek.it info@ntek.it +39 011 40 53 600