SlideShare a Scribd company logo
1 of 8
Download to read offline
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
10G 1550nm 40km ER XFP Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
2020-12-29 1.0 Jiang L
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 10G 1550nm 40km ER XFP Transceiver
Model XFP-10G-ER-55-T02
File No. XFP-10G-ER-55-T02#141156
Version 1.0
Issuing Date 2020-12-19
- 1 -
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
GLsun's XFP-10G-ER-55-T02 Small Form Factor 10Gb/s XFP transceivers comply with the current XFP
Multi-Source Agreement (MSA) Specification. They also comply with SONET OC-192 IR-2, OC-192 IR-3,
SDH STM S-64.2b, STM S-64.3b as well as with 10-Gigabit Ethernet 10GBASE-ER/EW per IEEE 802.3ae
and 40km 10G Fibre Channel applications. Digital diagnostics functions are available via a 2-wire serial
interface, as specified in the XFP MSA.
Product Feature
Supports 9.95 to 11.3Gb/s bit rates
Duplex LC connector
Hot-pluggable XFP footprint
Cooled 1550nm EML laser ,PIN photo-detector
Applicable for 40km SMF connection
Low power consumption, <2.0W
Digital Diagnostic Monitor Interface
No Reference Clock required
Operating case temperature:
Commercial: 0 to 70 °C
Industrial: -40 to 85°C
Application
10GBASE-ER/EW 10G Ethernet
40km 10G Fibre Channel
SONET OC-192 IR-2/3,SDH STM S-64.2/3b, ITU-T G.709
Other optical link
Functional Diagram
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Absolute Maximum Ratings
Parameter Symbol Min Max Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature TS -40 85 °C
Operating Humidity RH 0 85 %
Notes:
Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.
General Specifications
Parameter Symbol Min Typ Max Unit Note
Data Rate DR 9.95 11.3 Gb/s
Supply Voltage
Vcc3 3.13 3.45 V
Vcc5 4.75 5.25 V
Supply Current
Icc3 600 mA
Icc5 350 mA
Case Operating Temperature
Tc 0 70 °C
TI -40 85 °C
Electrical Characteristics
Parameter Symbol Min Typ Max Unit Note
Transmitter
Differential data input swing VIN,PP 120 820 mVpp
Transmit Disable Voltage VD 2.0 Vcc
V
1
Transmit Enable Voltage VEN Vee Vee+0.8
Input differential impedance Rin 100 Ω 2
Transmit Disable Assert Time Tda 10 us
Receiver
Differential data output swing Vout, pp 340 850 mVpp 3
Output rise time and fall time Tr, Tf 38 Ps 4
LOS Fault VLOS_F Vcc-0.5 Vcc V 5
LOS Normal VLOS_N Vee Vee+0.5 V 5
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Notes:
1. ER = 8.2dB minium for data rates 9.9Gb/s to 10.7Gb/s.
2. Guaranteed minimum OMA for 9.9Gb/s - 11.3Gb/s.
3. Measured with a host jitter of 50 mUI peak-to-peak per Telcordia GR-253.
4. Measured with a host jitter of 7 mUI RMS.
5. Measured with worst ER; BER<10-12; PRBS31. Equivalent to –14.3 dBm OMA at ER = 8.2 dB.
6. Dispersion penalty is measured in loopback using 18 ps/(nm*km) fiber (SMF-28). Path penalty is
2dBat 10.7Gb/s.
Notes:
1. Or open circuit.
2. After internal AC coupling.
3. Into 100 ohms differential termination.
4. 20 – 80 %.
5. Loss of Signal is open collector to be pulled up with a 4.7k ~ 10k resistor to 3.15 – 3.6V.
Logic 0, indicates normal operation; logic 1 indicates no signal detected.
Parameter Symbol Min Typ Max Unit Note
Transmitter
Operating Wavelength λ 1530 1565 nm
Ave. output power PAVE -1 +2 dBm 1
Optical Modulation Amplitude POMA -2.1 dBm 2
Extinction Ratio ER 8.2 dB 1
Sidemode Suppression Ratio SMSR 30 dB
SONET Tx Jitter(Peak to Peak) Txj 0.1 UI 3
Tx Jitter (RMS) 0.01 UI 4
Dispersion penalty (@800 ps/nm) TDP 2 dB
Relative Intensity Noise RIN -130 dB/Hz
Receiver
Operating Wavelength λ 1260 1620 nm
Receiver Sensitivity @10.3Gbps PSEN2 -16 dBm 5
Receiver Sensitivity @11.3Gbps PSEN2 -15 dBm 5
Overload Pmax -1 dBm
Receiver Reflectance Rrx -27 dB
Path penalty over 40Km@10.7G 2 dB 6
LOS Assert Pa -35 dBm
LOS De-assert Pd -22 dBm
LOS Hysteresis Pd-Pa 0.5 dB
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Pin Descriptions
PIN# Name Function Name/Description Notes
1 GND Module Ground 1
2 VEE5 Optional -5.2V Power Supply (Not requireed)
3
LVTTL-I MOD_DESEL
Module De-select; When held low allows the module to
respond to 2-wire serial interface
4 LVTTL-O Interrupt
Interrupt; Indicates presence of an important condition
which can be read via the 2-wire serial interface
2
5 LVTTL-I TX_DIS Transmitter Disable; Turns off transmitter laser output
6 VCC5 +5V Power Supply (Not required)
7 GND Module Ground 1
8 VCC3 +3.3V Power Supply
9 VCC3 +3.3V Power Supply
10 LVTTL-I/O SCL 2-Wire Serial Interface Clock 2
11 LVTTL-I/O SDA 2-Wire Serial Interface Data Line 2
12 LVTTL-O MOD_Abs Indicates Module is not present. Grounded in the
Module
2
13 LVTTL-O MOD_NR Module Not Ready; Indicating Module Operational Fault 2
14 LVTTL-O RX_LOS Receiver Loss Of Signal Indicator 2
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
15 GND Module Ground 1
16 GND Module Ground 1
17 CML-O RDN Receiver Inverted Data Output
18 CML-O RDP Receiver Non-Inverted Data Output
19 GND Module Ground 1
20 VCC2 +1.8V Power Supply (Not required).
21 LVTTL-I P_DOWN/RST
Power down; when high, the module limits power
consumption to 1.5 W or below. Serial interface is
functional in the low power mode. Reset: the falling
edge initiates a complete reset of the module including
the serial interface, equivalent to a power cycle.
22 VCC2 +1.8V Power Supply (Not required)
23 GND Module Ground 1
24 PECL-I REFCLK+ Not used, internally terminated to 50ohm (100ohm diff). 3
25 PECL-I REFCLK- Not used, internally terminated to 50ohm (100ohm diff). 3
26 GND Module Ground 1
27 GND Module Ground 1
28 CML-I TD- Transmitter Inverted Data Input
29 CML-I TD+ Transmitter Non-Inverted Data Input
30 GND Module Ground 1
Notes:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Open collector; should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15V
and 3.6V.
3. Reference Clock input is not required.
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
Management Interface
The XFP-10G-ER-55-T02 incorporates an XFP-compliant, two-wire management interface which is used
for serial ID, digital diagnostics, and certain control functions. It is modeled on the SFF-8472 specification
modified to accommodate a single two-wire interface address. In addition to the basic I2C read/write
functionality, the modules support packet error checking that, when enabled, allows the host system to
confirm the validity of any read data. Details of the protocol and interface are explicitly described in the
MSA. Please refer to the MSA for design reference.The digital diagnostic memory map specific data field
defines as following:
Typical Interface Circuit
XFP-10G-ER-55-T02#141156
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 8 -
Package Dimensions
Ordering Information
Part Number Description
XFP-10G-ER-55-T02-C
XFP,9.95 to 11.3Gb/s, 1550nm EML,40km, 0~70℃,
with Digital Diagnostic Monitor
XFP-10G-ER-55-T02-I
XFP,9.95 to 11.3Gb/s, 1550nm EML,40km, -40~80℃,
with Digital Diagnostic Monitor

More Related Content

Similar to xfp-10g-er-1550-40km-transceiver-module-141156.pdf

Similar to xfp-10g-er-1550-40km-transceiver-module-141156.pdf (20)

sfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdf
sfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdfsfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdf
sfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdf
 
sfp-1g-bx10u-1310nm-1550nm-10km-bidi-fiber-optical-module-151110-T03.pdf
sfp-1g-bx10u-1310nm-1550nm-10km-bidi-fiber-optical-module-151110-T03.pdfsfp-1g-bx10u-1310nm-1550nm-10km-bidi-fiber-optical-module-151110-T03.pdf
sfp-1g-bx10u-1310nm-1550nm-10km-bidi-fiber-optical-module-151110-T03.pdf
 
sfp-1g-ex-1550nm-40km-optical-transceiver-module-151012.pdf
sfp-1g-ex-1550nm-40km-optical-transceiver-module-151012.pdfsfp-1g-ex-1550nm-40km-optical-transceiver-module-151012.pdf
sfp-1g-ex-1550nm-40km-optical-transceiver-module-151012.pdf
 
spf-1g-bx80u-1490nm-1550nm-80km-bidi-fiber-optical-module-151019.pdf
spf-1g-bx80u-1490nm-1550nm-80km-bidi-fiber-optical-module-151019.pdfspf-1g-bx80u-1490nm-1550nm-80km-bidi-fiber-optical-module-151019.pdf
spf-1g-bx80u-1490nm-1550nm-80km-bidi-fiber-optical-module-151019.pdf
 
sfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdf
sfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdfsfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdf
sfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdf
 
sfp-1g-ex-1550nm-40km-fiber-optical-module-151013.pdf
sfp-1g-ex-1550nm-40km-fiber-optical-module-151013.pdfsfp-1g-ex-1550nm-40km-fiber-optical-module-151013.pdf
sfp-1g-ex-1550nm-40km-fiber-optical-module-151013.pdf
 
sfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdf
sfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdfsfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdf
sfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdf
 
sfp-1g-bx10d-1490nm-1310nm-10km-bidi-fiber-transceiver-151107-T03.pdf
sfp-1g-bx10d-1490nm-1310nm-10km-bidi-fiber-transceiver-151107-T03.pdfsfp-1g-bx10d-1490nm-1310nm-10km-bidi-fiber-transceiver-151107-T03.pdf
sfp-1g-bx10d-1490nm-1310nm-10km-bidi-fiber-transceiver-151107-T03.pdf
 
spf-1g-bx80d-1550nm-1490nm-80km-bidi-optical-module-151020.pdf
spf-1g-bx80d-1550nm-1490nm-80km-bidi-optical-module-151020.pdfspf-1g-bx80d-1550nm-1490nm-80km-bidi-optical-module-151020.pdf
spf-1g-bx80d-1550nm-1490nm-80km-bidi-optical-module-151020.pdf
 
sfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdf
sfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdfsfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdf
sfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdf
 
sfp-1g-zx-1550nm-80km-optical-transceiver-151004.pdf
sfp-1g-zx-1550nm-80km-optical-transceiver-151004.pdfsfp-1g-zx-1550nm-80km-optical-transceiver-151004.pdf
sfp-1g-zx-1550nm-80km-optical-transceiver-151004.pdf
 
sfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdf
sfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdfsfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdf
sfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdf
 
sfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdf
sfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdfsfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdf
sfp-2.5g-lh100-1550nm-100km-fiber-optical-module-151063.pdf
 
sfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdf
sfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdfsfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdf
sfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdf
 
sfp-2.5g-lh80-1550nm-80km-fiber-optical-module-151062.pdf
sfp-2.5g-lh80-1550nm-80km-fiber-optical-module-151062.pdfsfp-2.5g-lh80-1550nm-80km-fiber-optical-module-151062.pdf
sfp-2.5g-lh80-1550nm-80km-fiber-optical-module-151062.pdf
 
sfp-1g-bx20u-1310nm-1550nm-20km-bidi-fiber-transceiver-151006.pdf
sfp-1g-bx20u-1310nm-1550nm-20km-bidi-fiber-transceiver-151006.pdfsfp-1g-bx20u-1310nm-1550nm-20km-bidi-fiber-transceiver-151006.pdf
sfp-1g-bx20u-1310nm-1550nm-20km-bidi-fiber-transceiver-151006.pdf
 
sfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdf
sfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdfsfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdf
sfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdf
 
spf-1g-bx20d-1550nm-1310nm-20km-bidifiber-optic-transceiver--151005.pdf
spf-1g-bx20d-1550nm-1310nm-20km-bidifiber-optic-transceiver--151005.pdfspf-1g-bx20d-1550nm-1310nm-20km-bidifiber-optic-transceiver--151005.pdf
spf-1g-bx20d-1550nm-1310nm-20km-bidifiber-optic-transceiver--151005.pdf
 
spf-1g-bx40d-1490nm-1310nm-40km-bidi-fiber-optical-module-151018.pdf
spf-1g-bx40d-1490nm-1310nm-40km-bidi-fiber-optical-module-151018.pdfspf-1g-bx40d-1490nm-1310nm-40km-bidi-fiber-optical-module-151018.pdf
spf-1g-bx40d-1490nm-1310nm-40km-bidi-fiber-optical-module-151018.pdf
 
sfp-1g-ex-1550nm-40km-fiber-optical-module-151014.pdf
sfp-1g-ex-1550nm-40km-fiber-optical-module-151014.pdfsfp-1g-ex-1550nm-40km-fiber-optical-module-151014.pdf
sfp-1g-ex-1550nm-40km-fiber-optical-module-151014.pdf
 

More from GLsun Mall

osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
GLsun Mall
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
GLsun Mall
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
GLsun Mall
 

More from GLsun Mall (20)

to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfto56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
 
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfto56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
 
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfto56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
 
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfosw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
 
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfosw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
 
fsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docfsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.doc
 
fsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docfsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.doc
 
fsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docfsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.doc
 
fsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docfsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.doc
 
fsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docfsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.doc
 
multi-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfmulti-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdf
 
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
 
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
 
1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf
 
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
 
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
 
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
 

Recently uploaded

Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 

Recently uploaded (20)

Design and Development of a Provenance Capture Platform for Data Science
Design and Development of a Provenance Capture Platform for Data ScienceDesign and Development of a Provenance Capture Platform for Data Science
Design and Development of a Provenance Capture Platform for Data Science
 
Platformless Horizons for Digital Adaptability
Platformless Horizons for Digital AdaptabilityPlatformless Horizons for Digital Adaptability
Platformless Horizons for Digital Adaptability
 
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​Elevate Developer Efficiency & build GenAI Application with Amazon Q​
Elevate Developer Efficiency & build GenAI Application with Amazon Q​
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Simplifying Mobile A11y Presentation.pptx
Simplifying Mobile A11y Presentation.pptxSimplifying Mobile A11y Presentation.pptx
Simplifying Mobile A11y Presentation.pptx
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 
AI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by AnitarajAI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by Anitaraj
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptx
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
WSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering DevelopersWSO2's API Vision: Unifying Control, Empowering Developers
WSO2's API Vision: Unifying Control, Empowering Developers
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
The Zero-ETL Approach: Enhancing Data Agility and Insight
The Zero-ETL Approach: Enhancing Data Agility and InsightThe Zero-ETL Approach: Enhancing Data Agility and Insight
The Zero-ETL Approach: Enhancing Data Agility and Insight
 
ChatGPT and Beyond - Elevating DevOps Productivity
ChatGPT and Beyond - Elevating DevOps ProductivityChatGPT and Beyond - Elevating DevOps Productivity
ChatGPT and Beyond - Elevating DevOps Productivity
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
Introduction to Multilingual Retrieval Augmented Generation (RAG)
Introduction to Multilingual Retrieval Augmented Generation (RAG)Introduction to Multilingual Retrieval Augmented Generation (RAG)
Introduction to Multilingual Retrieval Augmented Generation (RAG)
 
WSO2 Micro Integrator for Enterprise Integration in a Decentralized, Microser...
WSO2 Micro Integrator for Enterprise Integration in a Decentralized, Microser...WSO2 Micro Integrator for Enterprise Integration in a Decentralized, Microser...
WSO2 Micro Integrator for Enterprise Integration in a Decentralized, Microser...
 
Modernizing Legacy Systems Using Ballerina
Modernizing Legacy Systems Using BallerinaModernizing Legacy Systems Using Ballerina
Modernizing Legacy Systems Using Ballerina
 

xfp-10g-er-1550-40km-transceiver-module-141156.pdf

  • 1. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 1 - 10G 1550nm 40km ER XFP Transceiver Specification Revision Record Date Version Page Revision Description Prepare Approve 2020-12-29 1.0 Jiang L All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission, any unit or individual can’t reproduce, copy or use it for any commercial purpose. Product 10G 1550nm 40km ER XFP Transceiver Model XFP-10G-ER-55-T02 File No. XFP-10G-ER-55-T02#141156 Version 1.0 Issuing Date 2020-12-19 - 1 -
  • 2. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 2 - Product Description GLsun's XFP-10G-ER-55-T02 Small Form Factor 10Gb/s XFP transceivers comply with the current XFP Multi-Source Agreement (MSA) Specification. They also comply with SONET OC-192 IR-2, OC-192 IR-3, SDH STM S-64.2b, STM S-64.3b as well as with 10-Gigabit Ethernet 10GBASE-ER/EW per IEEE 802.3ae and 40km 10G Fibre Channel applications. Digital diagnostics functions are available via a 2-wire serial interface, as specified in the XFP MSA. Product Feature Supports 9.95 to 11.3Gb/s bit rates Duplex LC connector Hot-pluggable XFP footprint Cooled 1550nm EML laser ,PIN photo-detector Applicable for 40km SMF connection Low power consumption, <2.0W Digital Diagnostic Monitor Interface No Reference Clock required Operating case temperature: Commercial: 0 to 70 °C Industrial: -40 to 85°C Application 10GBASE-ER/EW 10G Ethernet 40km 10G Fibre Channel SONET OC-192 IR-2/3,SDH STM S-64.2/3b, ITU-T G.709 Other optical link Functional Diagram
  • 3. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 3 - Absolute Maximum Ratings Parameter Symbol Min Max Unit Note Supply Voltage Vcc -0.5 4.0 V Storage Temperature TS -40 85 °C Operating Humidity RH 0 85 % Notes: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver. General Specifications Parameter Symbol Min Typ Max Unit Note Data Rate DR 9.95 11.3 Gb/s Supply Voltage Vcc3 3.13 3.45 V Vcc5 4.75 5.25 V Supply Current Icc3 600 mA Icc5 350 mA Case Operating Temperature Tc 0 70 °C TI -40 85 °C Electrical Characteristics Parameter Symbol Min Typ Max Unit Note Transmitter Differential data input swing VIN,PP 120 820 mVpp Transmit Disable Voltage VD 2.0 Vcc V 1 Transmit Enable Voltage VEN Vee Vee+0.8 Input differential impedance Rin 100 Ω 2 Transmit Disable Assert Time Tda 10 us Receiver Differential data output swing Vout, pp 340 850 mVpp 3 Output rise time and fall time Tr, Tf 38 Ps 4 LOS Fault VLOS_F Vcc-0.5 Vcc V 5 LOS Normal VLOS_N Vee Vee+0.5 V 5
  • 4. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 4 - Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V) Notes: 1. ER = 8.2dB minium for data rates 9.9Gb/s to 10.7Gb/s. 2. Guaranteed minimum OMA for 9.9Gb/s - 11.3Gb/s. 3. Measured with a host jitter of 50 mUI peak-to-peak per Telcordia GR-253. 4. Measured with a host jitter of 7 mUI RMS. 5. Measured with worst ER; BER<10-12; PRBS31. Equivalent to –14.3 dBm OMA at ER = 8.2 dB. 6. Dispersion penalty is measured in loopback using 18 ps/(nm*km) fiber (SMF-28). Path penalty is 2dBat 10.7Gb/s. Notes: 1. Or open circuit. 2. After internal AC coupling. 3. Into 100 ohms differential termination. 4. 20 – 80 %. 5. Loss of Signal is open collector to be pulled up with a 4.7k ~ 10k resistor to 3.15 – 3.6V. Logic 0, indicates normal operation; logic 1 indicates no signal detected. Parameter Symbol Min Typ Max Unit Note Transmitter Operating Wavelength λ 1530 1565 nm Ave. output power PAVE -1 +2 dBm 1 Optical Modulation Amplitude POMA -2.1 dBm 2 Extinction Ratio ER 8.2 dB 1 Sidemode Suppression Ratio SMSR 30 dB SONET Tx Jitter(Peak to Peak) Txj 0.1 UI 3 Tx Jitter (RMS) 0.01 UI 4 Dispersion penalty (@800 ps/nm) TDP 2 dB Relative Intensity Noise RIN -130 dB/Hz Receiver Operating Wavelength λ 1260 1620 nm Receiver Sensitivity @10.3Gbps PSEN2 -16 dBm 5 Receiver Sensitivity @11.3Gbps PSEN2 -15 dBm 5 Overload Pmax -1 dBm Receiver Reflectance Rrx -27 dB Path penalty over 40Km@10.7G 2 dB 6 LOS Assert Pa -35 dBm LOS De-assert Pd -22 dBm LOS Hysteresis Pd-Pa 0.5 dB
  • 5. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 5 - Pin Descriptions PIN# Name Function Name/Description Notes 1 GND Module Ground 1 2 VEE5 Optional -5.2V Power Supply (Not requireed) 3 LVTTL-I MOD_DESEL Module De-select; When held low allows the module to respond to 2-wire serial interface 4 LVTTL-O Interrupt Interrupt; Indicates presence of an important condition which can be read via the 2-wire serial interface 2 5 LVTTL-I TX_DIS Transmitter Disable; Turns off transmitter laser output 6 VCC5 +5V Power Supply (Not required) 7 GND Module Ground 1 8 VCC3 +3.3V Power Supply 9 VCC3 +3.3V Power Supply 10 LVTTL-I/O SCL 2-Wire Serial Interface Clock 2 11 LVTTL-I/O SDA 2-Wire Serial Interface Data Line 2 12 LVTTL-O MOD_Abs Indicates Module is not present. Grounded in the Module 2 13 LVTTL-O MOD_NR Module Not Ready; Indicating Module Operational Fault 2 14 LVTTL-O RX_LOS Receiver Loss Of Signal Indicator 2
  • 6. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 6 - 15 GND Module Ground 1 16 GND Module Ground 1 17 CML-O RDN Receiver Inverted Data Output 18 CML-O RDP Receiver Non-Inverted Data Output 19 GND Module Ground 1 20 VCC2 +1.8V Power Supply (Not required). 21 LVTTL-I P_DOWN/RST Power down; when high, the module limits power consumption to 1.5 W or below. Serial interface is functional in the low power mode. Reset: the falling edge initiates a complete reset of the module including the serial interface, equivalent to a power cycle. 22 VCC2 +1.8V Power Supply (Not required) 23 GND Module Ground 1 24 PECL-I REFCLK+ Not used, internally terminated to 50ohm (100ohm diff). 3 25 PECL-I REFCLK- Not used, internally terminated to 50ohm (100ohm diff). 3 26 GND Module Ground 1 27 GND Module Ground 1 28 CML-I TD- Transmitter Inverted Data Input 29 CML-I TD+ Transmitter Non-Inverted Data Input 30 GND Module Ground 1 Notes: 1. Module circuit ground is isolated from module chassis ground within the module. 2. Open collector; should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15V and 3.6V. 3. Reference Clock input is not required.
  • 7. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 7 - Management Interface The XFP-10G-ER-55-T02 incorporates an XFP-compliant, two-wire management interface which is used for serial ID, digital diagnostics, and certain control functions. It is modeled on the SFF-8472 specification modified to accommodate a single two-wire interface address. In addition to the basic I2C read/write functionality, the modules support packet error checking that, when enabled, allows the host system to confirm the validity of any read data. Details of the protocol and interface are explicitly described in the MSA. Please refer to the MSA for design reference.The digital diagnostic memory map specific data field defines as following: Typical Interface Circuit
  • 8. XFP-10G-ER-55-T02#141156 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 8 - Package Dimensions Ordering Information Part Number Description XFP-10G-ER-55-T02-C XFP,9.95 to 11.3Gb/s, 1550nm EML,40km, 0~70℃, with Digital Diagnostic Monitor XFP-10G-ER-55-T02-I XFP,9.95 to 11.3Gb/s, 1550nm EML,40km, -40~80℃, with Digital Diagnostic Monitor