10G 1532.68nm 40km DWDM SFP+ Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20210714 1.0 Liu YM
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 10G 1532.68nm 40km DWDM SFP+ Transceiver
Model DWDM-SFP10G-40-C56-T02
File No. DWDM-SFP10G-40-C56-T02#141102
Version 1.0
Issuing Date 2020-06-13
- 1 -
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
DWDM-SFP10G-40-C19-T02 Enhanced Small Form Factor Pluggable SFP+ transceivers are designed for
use in 10-Gigabit Ethernet links up to 40km over SingleMode fiber. They are compliant with SFF-
8431,SFF-8432 and ITU-T G.698.1. The transceiver designs are optimized for high performance and cost
effective to supply customers the best solutions for telecommunication.
This transceiver consists of two sections: The transmitter section incorporates a cooled EML laser. And the
receiver section consists of a PIN photodiode integrated with a TIA. All modules satisfy class I laser safety
requirements. Digital diagnostics functions are available via a 2-wire serial interface, as specified in
SFF-8472, which allows real-time access to device operating parameters such as transceiver temperature,
laser bias current, transmitted optical power, received optical power and transceiver supply voltage
Product Feature
Supports 9.95 to 11.3 Gb/s bit rates
Duplex LC connector
Hot pluggable SFP+ footprint
Cooled EML transmitter and PIN-TIA receiver
Applicable for 40km SMF connection
Low power consumption, < 1.2W
100 GHz channel spacing
Digital Diagnostic Monitor Interface
Optical interface compliant to ITU-T 694.1& G.698.1
Electrical interface compliant to SFF-8431& SFF-8432
Operating case temperature: Commercial: 0 to 70 °C, Industrial: -40 to 85 °C
Applications
10G Ethernet
2x,4x, 8x Fiber Channel
ITU-T G.698.1
Other optical links
Functional Diagram
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Absolute Maximum Ratings
General Operating Characteristics
Parameter Symbol Min Typ Max Unit Note
Data Rate DR 9.95 10.3125 11.3 Gb/s
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc 360 mA
Operating Case Temp.
Tc 0 70
°C
TI -40 85
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V)
Parameter Symbol Min Max Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature TS -40 85 °C
Relative Humidity RH 0 85 %
Parameter Symbol Min Typ Max Unit Note
Transmitter
Differential data input swing VIN,PP 120 850 mVpp
Transmit Disable Voltage VD VCC-0.8 Vcc V
Transmit Enable Voltage VEN Vee Vee+0.8 V
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 340 800 mVpp
Output rise time and fall time Tr, Tf 28 Ps 1
LOS asserted VLOS_F VCC-0.8 Vcc V 2
LOS de-asserted VLOS_N Vee Vee+0.8 V 2
Notes:
1.20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and four
0’s sequence in the PRBS 9 is an acceptable alternative.
2.LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal
operation is logic 0; loss of signal is logic 1.
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Optical Characteristics (TOP(C) = 0 to 70 °C, TOP(I) =-40 to 85 °C,VCC = 3.13 to 3.47 V)
Pin Descriptions
Pin Symbol Name Note
1 VEET Transmitter Ground 1
2 Tx_FAULT Transmitter Fault 2
3 Tx_DIS Transmitter Disable. Laser output disabled on high or open 3
4 SDA 2-wire Serial Interface Data Line 2
5 SCL 2-wire Serial Interface Clock Line 2
6 MOD_ABS Module Absent. Grounded within the module 4
7 RS0 Rate Select 0
Parameter Symbol Min Typ Max Unit Note
Transmitter
Center Wavelength λc 1528.77 1563.86 nm
Center Wavelength (End of Life) λc_EOL λc±100pm
Ave. output power (Enabled) PAVE -1 2 dBm 1
Side-Mode Suppression Ratio SMSR 30 dB
Extinction Ratio ER 8.2 dB
RMS spectral width Δλ 1 nm
Rise/Fall time (20%~80%) Tr/Tf 50 ps
Relative Intensity Noise RIN -128 dB/Hz
Receiver
Operating Wavelength λ 1260 1600 nm
Receiver Sensitivity PSEN -16 dBm 2
Overload PAVE +0.5 dBm
LOS Assert Pa -30 dBm
LOS De-assert Pd -18 dBm
LOS Hysteresis Pd-Pa 0.5 dB
Notes:
1. Measured 231 – 1
PRBS@10.3125G
2. Measured with worst ER=8.2dB; 231 – 1 PRBS@10.3125G
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
8 RX_LOS Loss of Signal indication. Logic 0 indicates normal operation 2
9 RS1 Rate Select 1 1
10 VEER Receiver Ground
11 VEER Receiver Ground 1
12 RD- Receiver Inverted DATA out. AC Coupled
13 RD+ Receiver DATA out. AC Coupled
14 VEER Receiver Ground 1
15 VCCR Receiver Power Supply
16 VCCT Transmitter Power Supply
17 VEET TranGround 1
18 TD+ Transmitter DATA in. AC Coupled
19 TD- Transmitter Inverted DATA in. AC Coupled
20 VEET Transmitter Ground 1
Notes:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15V and 3.6V.
3. Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module.
4. Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to
Vcc_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+ module
is physically absent from a host slot.
Pin Definition And Functions
Serial Interface for ID and Digital Diagnostic Monitor
DWDM-SFP10G-40-C19-T02 transceiver support the 2-wire serial communication protocol as defined in
the SFP+ MSA. The standard SFP+ serial ID provides access to identification information that describes
the transceiver’s capabilities, standard interfaces, manufacturer, and other information. Additionally, This
SFP+ transceivers provide an enhanced digital diagnostic monitoring interface, which allows real-time
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
access to device operating parameters such as transceiver temperature, laser bias current,
transmitted optical power, received optical power and transceiver supply voltage. It also defines a
sophisticated system of alarm and warning flags, which alerts end-users when particular operating
parameters are outside of a factory set normal range.
The SFP MSA defines a 256-byte memory map in EEPROM that is accessible over a 2-wire serial interface
at the 8 bit address 1010000X(A0h), so the originally monitoring interface makes use of the 8 bit
address(A2h), so the originally defined serial ID memory map remains unchanged. The structure of the
memory map is shown in Table1.
Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)
Digital Diagnostic Specifications
DWDM-SFP10G-40-C19-T02 transceivers can be used in host systems that require either internally or
externally calibrated digital diagnostics.
Typical Interface Circuit
Parameter Symbol Unit Min Max Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1,2
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 0 127 ±10% 3
Transmitter output power DTx-Power dBm -3 +4 ±2dB
Receiver average input power DRx-Power dBm -18 0 ±2dB
Notes:
1. When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75
2. Internally measured
3. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
Recommended power supply filter
Note:
Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the
SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot
plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than
the steady state value
Package Dimensions
DWDM-SFP10G-40-C56-T02#141102
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 8 -
Ordering Information
Part Number Operating Case temperature DDMI
DWDM-SFP10G-40-C56-T02 Commercial(0~70°C) Yes

More Related Content

Similar to dwdm-sfp10g-40km-c56-optical-module-141102.doc

DWDM-SFP10G-40-C57-T02#141103.pdf
DWDM-SFP10G-40-C57-T02#141103.pdfDWDM-SFP10G-40-C57-T02#141103.pdf
DWDM-SFP10G-40-C57-T02#141103.pdfGLsun Mall
 
DWDM-SFP10G-40-C50-T02#141096.pdf
DWDM-SFP10G-40-C50-T02#141096.pdfDWDM-SFP10G-40-C50-T02#141096.pdf
DWDM-SFP10G-40-C50-T02#141096.pdfGLsun Mall
 
DWDM-SFP10G-40-C18-T02#141064.pdf
DWDM-SFP10G-40-C18-T02#141064.pdfDWDM-SFP10G-40-C18-T02#141064.pdf
DWDM-SFP10G-40-C18-T02#141064.pdfGLsun Mall
 
DWDM-SFP10G-40-C54-T02#141100.pdf
DWDM-SFP10G-40-C54-T02#141100.pdfDWDM-SFP10G-40-C54-T02#141100.pdf
DWDM-SFP10G-40-C54-T02#141100.pdfGLsun Mall
 
DWDM-SFP10G-40-C56-T02#141102.pdf
DWDM-SFP10G-40-C56-T02#141102.pdfDWDM-SFP10G-40-C56-T02#141102.pdf
DWDM-SFP10G-40-C56-T02#141102.pdfGLsun Mall
 
DWDM-SFP10G-40-C59-T02#141105.pdf
DWDM-SFP10G-40-C59-T02#141105.pdfDWDM-SFP10G-40-C59-T02#141105.pdf
DWDM-SFP10G-40-C59-T02#141105.pdfGLsun Mall
 
DWDM-SFP10G-40-C55-T02#141101.pdf
DWDM-SFP10G-40-C55-T02#141101.pdfDWDM-SFP10G-40-C55-T02#141101.pdf
DWDM-SFP10G-40-C55-T02#141101.pdfGLsun Mall
 
dwdm-sfp10g-40km-c55-transceiver-module-141101.pdf
dwdm-sfp10g-40km-c55-transceiver-module-141101.pdfdwdm-sfp10g-40km-c55-transceiver-module-141101.pdf
dwdm-sfp10g-40km-c55-transceiver-module-141101.pdfGLsun Mall
 
DWDM-SFP10G-40-C53-T02#141099.pdf
DWDM-SFP10G-40-C53-T02#141099.pdfDWDM-SFP10G-40-C53-T02#141099.pdf
DWDM-SFP10G-40-C53-T02#141099.pdfGLsun Mall
 
DWDM-SFP10G-40-C51-T02#141097.pdf
DWDM-SFP10G-40-C51-T02#141097.pdfDWDM-SFP10G-40-C51-T02#141097.pdf
DWDM-SFP10G-40-C51-T02#141097.pdfGLsun Mall
 
DWDM-SFP10G-40-C30-T02#141076.pdf
DWDM-SFP10G-40-C30-T02#141076.pdfDWDM-SFP10G-40-C30-T02#141076.pdf
DWDM-SFP10G-40-C30-T02#141076.pdfGLsun Mall
 
dwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdf
dwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdfdwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdf
dwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdfGLsun Mall
 
DWDM-SFP10G-40-C33-T02#141079.pdf
DWDM-SFP10G-40-C33-T02#141079.pdfDWDM-SFP10G-40-C33-T02#141079.pdf
DWDM-SFP10G-40-C33-T02#141079.pdfGLsun Mall
 
dwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdf
dwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdfdwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdf
dwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdfGLsun Mall
 
DWDM-SFP10G-40-C27-T02#141073.pdf
DWDM-SFP10G-40-C27-T02#141073.pdfDWDM-SFP10G-40-C27-T02#141073.pdf
DWDM-SFP10G-40-C27-T02#141073.pdfGLsun Mall
 
DWDM-SFP10G-40-C34-T02#141080.pdf
DWDM-SFP10G-40-C34-T02#141080.pdfDWDM-SFP10G-40-C34-T02#141080.pdf
DWDM-SFP10G-40-C34-T02#141080.pdfGLsun Mall
 
dwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdf
dwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdfdwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdf
dwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdfGLsun Mall
 
DWDM-SFP10G-40-C60-T02#141106.pdf
DWDM-SFP10G-40-C60-T02#141106.pdfDWDM-SFP10G-40-C60-T02#141106.pdf
DWDM-SFP10G-40-C60-T02#141106.pdfGLsun Mall
 
DWDM-SFP10G-40-C61-T02#141107.pdf
DWDM-SFP10G-40-C61-T02#141107.pdfDWDM-SFP10G-40-C61-T02#141107.pdf
DWDM-SFP10G-40-C61-T02#141107.pdfGLsun Mall
 
DWDM-SFP10G-40-C52-T02#141098.pdf
DWDM-SFP10G-40-C52-T02#141098.pdfDWDM-SFP10G-40-C52-T02#141098.pdf
DWDM-SFP10G-40-C52-T02#141098.pdfGLsun Mall
 

Similar to dwdm-sfp10g-40km-c56-optical-module-141102.doc (20)

DWDM-SFP10G-40-C57-T02#141103.pdf
DWDM-SFP10G-40-C57-T02#141103.pdfDWDM-SFP10G-40-C57-T02#141103.pdf
DWDM-SFP10G-40-C57-T02#141103.pdf
 
DWDM-SFP10G-40-C50-T02#141096.pdf
DWDM-SFP10G-40-C50-T02#141096.pdfDWDM-SFP10G-40-C50-T02#141096.pdf
DWDM-SFP10G-40-C50-T02#141096.pdf
 
DWDM-SFP10G-40-C18-T02#141064.pdf
DWDM-SFP10G-40-C18-T02#141064.pdfDWDM-SFP10G-40-C18-T02#141064.pdf
DWDM-SFP10G-40-C18-T02#141064.pdf
 
DWDM-SFP10G-40-C54-T02#141100.pdf
DWDM-SFP10G-40-C54-T02#141100.pdfDWDM-SFP10G-40-C54-T02#141100.pdf
DWDM-SFP10G-40-C54-T02#141100.pdf
 
DWDM-SFP10G-40-C56-T02#141102.pdf
DWDM-SFP10G-40-C56-T02#141102.pdfDWDM-SFP10G-40-C56-T02#141102.pdf
DWDM-SFP10G-40-C56-T02#141102.pdf
 
DWDM-SFP10G-40-C59-T02#141105.pdf
DWDM-SFP10G-40-C59-T02#141105.pdfDWDM-SFP10G-40-C59-T02#141105.pdf
DWDM-SFP10G-40-C59-T02#141105.pdf
 
DWDM-SFP10G-40-C55-T02#141101.pdf
DWDM-SFP10G-40-C55-T02#141101.pdfDWDM-SFP10G-40-C55-T02#141101.pdf
DWDM-SFP10G-40-C55-T02#141101.pdf
 
dwdm-sfp10g-40km-c55-transceiver-module-141101.pdf
dwdm-sfp10g-40km-c55-transceiver-module-141101.pdfdwdm-sfp10g-40km-c55-transceiver-module-141101.pdf
dwdm-sfp10g-40km-c55-transceiver-module-141101.pdf
 
DWDM-SFP10G-40-C53-T02#141099.pdf
DWDM-SFP10G-40-C53-T02#141099.pdfDWDM-SFP10G-40-C53-T02#141099.pdf
DWDM-SFP10G-40-C53-T02#141099.pdf
 
DWDM-SFP10G-40-C51-T02#141097.pdf
DWDM-SFP10G-40-C51-T02#141097.pdfDWDM-SFP10G-40-C51-T02#141097.pdf
DWDM-SFP10G-40-C51-T02#141097.pdf
 
DWDM-SFP10G-40-C30-T02#141076.pdf
DWDM-SFP10G-40-C30-T02#141076.pdfDWDM-SFP10G-40-C30-T02#141076.pdf
DWDM-SFP10G-40-C30-T02#141076.pdf
 
dwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdf
dwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdfdwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdf
dwdm-sfp10g-40km-c30-fiber-transceiver-module-data-sheet-141076.pdf
 
DWDM-SFP10G-40-C33-T02#141079.pdf
DWDM-SFP10G-40-C33-T02#141079.pdfDWDM-SFP10G-40-C33-T02#141079.pdf
DWDM-SFP10G-40-C33-T02#141079.pdf
 
dwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdf
dwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdfdwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdf
dwdm-sfp10g-40km-c33-fiber-transceiver-module-data-sheet-141079.pdf
 
DWDM-SFP10G-40-C27-T02#141073.pdf
DWDM-SFP10G-40-C27-T02#141073.pdfDWDM-SFP10G-40-C27-T02#141073.pdf
DWDM-SFP10G-40-C27-T02#141073.pdf
 
DWDM-SFP10G-40-C34-T02#141080.pdf
DWDM-SFP10G-40-C34-T02#141080.pdfDWDM-SFP10G-40-C34-T02#141080.pdf
DWDM-SFP10G-40-C34-T02#141080.pdf
 
dwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdf
dwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdfdwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdf
dwdm-sfp10g-40km-c34-fiber-transceiver-module-data-sheet-141080.pdf
 
DWDM-SFP10G-40-C60-T02#141106.pdf
DWDM-SFP10G-40-C60-T02#141106.pdfDWDM-SFP10G-40-C60-T02#141106.pdf
DWDM-SFP10G-40-C60-T02#141106.pdf
 
DWDM-SFP10G-40-C61-T02#141107.pdf
DWDM-SFP10G-40-C61-T02#141107.pdfDWDM-SFP10G-40-C61-T02#141107.pdf
DWDM-SFP10G-40-C61-T02#141107.pdf
 
DWDM-SFP10G-40-C52-T02#141098.pdf
DWDM-SFP10G-40-C52-T02#141098.pdfDWDM-SFP10G-40-C52-T02#141098.pdf
DWDM-SFP10G-40-C52-T02#141098.pdf
 

More from GLsun Mall

to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfto56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfGLsun Mall
 
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfto56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfGLsun Mall
 
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfto56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfGLsun Mall
 
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfosw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfGLsun Mall
 
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfosw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfGLsun Mall
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfGLsun Mall
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfGLsun Mall
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfGLsun Mall
 
fsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docfsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docGLsun Mall
 
fsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docfsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docGLsun Mall
 
fsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docfsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docGLsun Mall
 
fsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docfsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docGLsun Mall
 
fsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docfsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docGLsun Mall
 
multi-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfmulti-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfGLsun Mall
 
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdfGLsun Mall
 
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdfGLsun Mall
 
1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdfGLsun Mall
 
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdfGLsun Mall
 
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdfGLsun Mall
 
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdfGLsun Mall
 

More from GLsun Mall (20)

to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfto56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
 
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfto56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
 
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfto56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
 
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfosw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
 
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfosw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
 
fsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docfsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.doc
 
fsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docfsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.doc
 
fsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docfsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.doc
 
fsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docfsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.doc
 
fsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docfsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.doc
 
multi-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfmulti-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdf
 
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
 
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
 
1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf
 
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
 
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
 
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
 

Recently uploaded

#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxnull - The Open Security Community
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Scott Keck-Warren
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Bluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfBluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfngoud9212
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersThousandEyes
 
Science&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdfScience&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdfjimielynbastida
 
Unlocking the Potential of the Cloud for IBM Power Systems
Unlocking the Potential of the Cloud for IBM Power SystemsUnlocking the Potential of the Cloud for IBM Power Systems
Unlocking the Potential of the Cloud for IBM Power SystemsPrecisely
 
costume and set research powerpoint presentation
costume and set research powerpoint presentationcostume and set research powerpoint presentation
costume and set research powerpoint presentationphoebematthew05
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024BookNet Canada
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDGMarianaLemus7
 
Pigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions
 
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024BookNet Canada
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 

Recently uploaded (20)

#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
#StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
 
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptxMaking_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
Making_way_through_DLL_hollowing_inspite_of_CFG_by_Debjeet Banerjee.pptx
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
Vulnerability_Management_GRC_by Sohang Sengupta.pptx
Vulnerability_Management_GRC_by Sohang Sengupta.pptxVulnerability_Management_GRC_by Sohang Sengupta.pptx
Vulnerability_Management_GRC_by Sohang Sengupta.pptx
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Bluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdfBluetooth Controlled Car with Arduino.pdf
Bluetooth Controlled Car with Arduino.pdf
 
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for PartnersEnhancing Worker Digital Experience: A Hands-on Workshop for Partners
Enhancing Worker Digital Experience: A Hands-on Workshop for Partners
 
Science&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdfScience&tech:THE INFORMATION AGE STS.pdf
Science&tech:THE INFORMATION AGE STS.pdf
 
Unlocking the Potential of the Cloud for IBM Power Systems
Unlocking the Potential of the Cloud for IBM Power SystemsUnlocking the Potential of the Cloud for IBM Power Systems
Unlocking the Potential of the Cloud for IBM Power Systems
 
costume and set research powerpoint presentation
costume and set research powerpoint presentationcostume and set research powerpoint presentation
costume and set research powerpoint presentation
 
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
Transcript: #StandardsGoals for 2024: What’s new for BISAC - Tech Forum 2024
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDG
 
Pigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping ElbowsPigging Solutions Piggable Sweeping Elbows
Pigging Solutions Piggable Sweeping Elbows
 
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
New from BookNet Canada for 2024: BNC BiblioShare - Tech Forum 2024
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 

dwdm-sfp10g-40km-c56-optical-module-141102.doc

  • 1. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 1 - 10G 1532.68nm 40km DWDM SFP+ Transceiver Specification Revision Record Date Version Page Revision Description Prepare Approve 20210714 1.0 Liu YM All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission, any unit or individual can’t reproduce, copy or use it for any commercial purpose. Product 10G 1532.68nm 40km DWDM SFP+ Transceiver Model DWDM-SFP10G-40-C56-T02 File No. DWDM-SFP10G-40-C56-T02#141102 Version 1.0 Issuing Date 2020-06-13 - 1 -
  • 2. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 2 - Product Description DWDM-SFP10G-40-C19-T02 Enhanced Small Form Factor Pluggable SFP+ transceivers are designed for use in 10-Gigabit Ethernet links up to 40km over SingleMode fiber. They are compliant with SFF- 8431,SFF-8432 and ITU-T G.698.1. The transceiver designs are optimized for high performance and cost effective to supply customers the best solutions for telecommunication. This transceiver consists of two sections: The transmitter section incorporates a cooled EML laser. And the receiver section consists of a PIN photodiode integrated with a TIA. All modules satisfy class I laser safety requirements. Digital diagnostics functions are available via a 2-wire serial interface, as specified in SFF-8472, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage Product Feature Supports 9.95 to 11.3 Gb/s bit rates Duplex LC connector Hot pluggable SFP+ footprint Cooled EML transmitter and PIN-TIA receiver Applicable for 40km SMF connection Low power consumption, < 1.2W 100 GHz channel spacing Digital Diagnostic Monitor Interface Optical interface compliant to ITU-T 694.1& G.698.1 Electrical interface compliant to SFF-8431& SFF-8432 Operating case temperature: Commercial: 0 to 70 °C, Industrial: -40 to 85 °C Applications 10G Ethernet 2x,4x, 8x Fiber Channel ITU-T G.698.1 Other optical links Functional Diagram
  • 3. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 3 - Absolute Maximum Ratings General Operating Characteristics Parameter Symbol Min Typ Max Unit Note Data Rate DR 9.95 10.3125 11.3 Gb/s Supply Voltage Vcc 3.13 3.3 3.47 V Supply Current Icc 360 mA Operating Case Temp. Tc 0 70 °C TI -40 85 Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃,VCC = 3.13 to 3.47 V) Parameter Symbol Min Max Unit Note Supply Voltage Vcc -0.5 4.0 V Storage Temperature TS -40 85 °C Relative Humidity RH 0 85 % Parameter Symbol Min Typ Max Unit Note Transmitter Differential data input swing VIN,PP 120 850 mVpp Transmit Disable Voltage VD VCC-0.8 Vcc V Transmit Enable Voltage VEN Vee Vee+0.8 V Input differential impedance Rin 100 Ω Receiver Differential data output swing Vout,pp 340 800 mVpp Output rise time and fall time Tr, Tf 28 Ps 1 LOS asserted VLOS_F VCC-0.8 Vcc V 2 LOS de-asserted VLOS_N Vee Vee+0.8 V 2 Notes: 1.20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and four 0’s sequence in the PRBS 9 is an acceptable alternative. 2.LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1.
  • 4. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 4 - Optical Characteristics (TOP(C) = 0 to 70 °C, TOP(I) =-40 to 85 °C,VCC = 3.13 to 3.47 V) Pin Descriptions Pin Symbol Name Note 1 VEET Transmitter Ground 1 2 Tx_FAULT Transmitter Fault 2 3 Tx_DIS Transmitter Disable. Laser output disabled on high or open 3 4 SDA 2-wire Serial Interface Data Line 2 5 SCL 2-wire Serial Interface Clock Line 2 6 MOD_ABS Module Absent. Grounded within the module 4 7 RS0 Rate Select 0 Parameter Symbol Min Typ Max Unit Note Transmitter Center Wavelength λc 1528.77 1563.86 nm Center Wavelength (End of Life) λc_EOL λc±100pm Ave. output power (Enabled) PAVE -1 2 dBm 1 Side-Mode Suppression Ratio SMSR 30 dB Extinction Ratio ER 8.2 dB RMS spectral width Δλ 1 nm Rise/Fall time (20%~80%) Tr/Tf 50 ps Relative Intensity Noise RIN -128 dB/Hz Receiver Operating Wavelength λ 1260 1600 nm Receiver Sensitivity PSEN -16 dBm 2 Overload PAVE +0.5 dBm LOS Assert Pa -30 dBm LOS De-assert Pd -18 dBm LOS Hysteresis Pd-Pa 0.5 dB Notes: 1. Measured 231 – 1 PRBS@10.3125G 2. Measured with worst ER=8.2dB; 231 – 1 PRBS@10.3125G
  • 5. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 5 - 8 RX_LOS Loss of Signal indication. Logic 0 indicates normal operation 2 9 RS1 Rate Select 1 1 10 VEER Receiver Ground 11 VEER Receiver Ground 1 12 RD- Receiver Inverted DATA out. AC Coupled 13 RD+ Receiver DATA out. AC Coupled 14 VEER Receiver Ground 1 15 VCCR Receiver Power Supply 16 VCCT Transmitter Power Supply 17 VEET TranGround 1 18 TD+ Transmitter DATA in. AC Coupled 19 TD- Transmitter Inverted DATA in. AC Coupled 20 VEET Transmitter Ground 1 Notes: 1. Module circuit ground is isolated from module chassis ground within the module. 2. Should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15V and 3.6V. 3. Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VccT inside the module. 4. Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to Vcc_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+ module is physically absent from a host slot. Pin Definition And Functions Serial Interface for ID and Digital Diagnostic Monitor DWDM-SFP10G-40-C19-T02 transceiver support the 2-wire serial communication protocol as defined in the SFP+ MSA. The standard SFP+ serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information. Additionally, This SFP+ transceivers provide an enhanced digital diagnostic monitoring interface, which allows real-time
  • 6. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 6 - access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range. The SFP MSA defines a 256-byte memory map in EEPROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X(A0h), so the originally monitoring interface makes use of the 8 bit address(A2h), so the originally defined serial ID memory map remains unchanged. The structure of the memory map is shown in Table1. Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions) Digital Diagnostic Specifications DWDM-SFP10G-40-C19-T02 transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics. Typical Interface Circuit Parameter Symbol Unit Min Max Accuracy Note Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1,2 Transceiver supply voltage DVoltage V 2.8 4.0 ±3% Transmitter bias current DBias mA 0 127 ±10% 3 Transmitter output power DTx-Power dBm -3 +4 ±2dB Receiver average input power DRx-Power dBm -18 0 ±2dB Notes: 1. When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75 2. Internally measured 3. The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
  • 7. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 7 - Recommended power supply filter Note: Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value Package Dimensions
  • 8. DWDM-SFP10G-40-C56-T02#141102 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 8 - Ordering Information Part Number Operating Case temperature DDMI DWDM-SFP10G-40-C56-T02 Commercial(0~70°C) Yes