3. Boaray 5000D High-End Ventilator
• 20ml minimum Vt which is adaptive to all patients from infants to adults.
• Full ventilation modes which are available for all clinical departments including
respiratory, ICU, etc.
• Special VCV function (Flow Support Function)
• Core components from world famous brands (same suppliers as top ventilator
manufacturers - high precision, stability and safety).
• Spontaneous breathing monitoring (weaning software), related compensation.
• User-friendly interface, full monitoring and intelligent alarm.
• 15" Color touch screen: easier operation, more monitoring parameters.
Boaray 5000D Ventilator
4. Full Ventilation Modes
Ventilation modes:
VCV(Volume Controlled Ventilation)
PCV(Pressure Controlled Ventilation)
SIMV+VCV+PSV
(volume controlled synchronized intermittent mandatory ventilation
supported with pressure control)
SIMV+PCV+PSV
(pressure controlled synchronized intermittent mandatory
ventilation supported with volume control)
Standby
DualPAP
In VCV mode, Vt can be set as low as 20ml
Demand from all critical patients (adults and pediatrics) can be met.
Ventilation modes setting:parameters
change with switch of modes in case of
misoperation.
Boaray 5000D Ventilator
5. Volume SIMV = SIMV+VCV+PSV
Pressure SIMV = SIMV+PCV+PSV
Ventilation mode is selected with one key, and the
corresponding parameters can be set in the same page.
Mechanical ventilation & spontaneous breathing together
constitute the MV.
Pressure supported Pinsp, i.e. SIMV+VCV+PSV /
SIMV+PCV+PSV
Ventilation mode Parameter settings
Full Ventilation Modes
Boaray 5000D Ventilator
6. DualPAP
(Dual-level Positive Airway Pressure)
DualPAP is a patent of Prunus
DualPAP = BIPAP = BiPAP
BIPAP
PCV CPAP
Pressure-controlled
ventilation ensuring
free breathing
Pressure-supported
ventilation with
»smooth« time control
Pressure Control
(Ensure spontaneous
breathing)
Continuous Positive
Airway Pressure
(Soft Control)
DualPAP
It combines both the advantages of PCV and the SPONT
feature of CPAP.
SPONT is available both in the high pressure phase and
low pressure phase.
PSV works both in the high pressure phase and low
pressure phase.
Full Ventilation Modes
Boaray 5000D Ventilator
7. Flow Support - Prunus Unique VCV
It can accurately achieve required volume.
Minimum Vt can be set to 20ml.
The flow waveform can be square wave or decelerating wave.
Active vent valve: 5MS high-speed response.
Flow and pressure trigger (sensitivity adjustable).
A/C (auxiliary/volume control) function that allows or encourages
triggering.
No more worry about patients' breathing, so easy
Prunus' flow support function can be selectected under square wave
or decelarating wave, which is a rare function in top ventilators.
Boaray 5000D Ventilator
8. 15" large color touch screen
Real-time display of monitoring parameters
Parameter Settings
Dynamic waveform
Pulmonary function loop
User-friendly Interface
Boaray 5000D Ventilator
9. Large font for remote viewing:
It can be observed from 3Maway and
from multiple angles, which is suitable for
various clinical environments.
User-friendly Interface
Boaray 5000D Ventilator
11. Accurate ventilation control and advanced monitoring technology
Original imported valve and sensor and advanced algorithm ensure the world-class Boaray 5000D
Closed-loop control system
Real-time dynamic compensation
Leakage compensation
Tubingcompliance
Fresh gas flow compensation
G(s)
H(s)
C(s)
R(s) E(s)
误差
B(s)
+
-
输出
参考
反馈
闭环系统框图
Intelligent electronic PEEP
Active vent valve
Detachable
Enabling HTHP disinfection
Reducing the possibility of cross infection
Feedback
Feedback
Deviation
Output
Closed-Loop System Chart
Reference
Boaray 5000D Ventilator
12. Core Components from top suppliers around the world
(same suppliers as top ventilator manufacturers - high precision, stability and safety)
Pressure, flow rate and volume: 3 elements of fluid mechanics
Safety, stability and precision: 3 elements of product quality
Proportional valve and sensor to anesthesia machine is what
engine and monitoring system to car, and what CPU to computer.
Electromagnetic
Proportional Valve
Pressure Sensor
Flow Sensor
Pressure Regulating
Valve
Boaray 5000D Ventilator
13. Accurate ventilation control - dual monitoring of expiration and inspiration
Unique sensor technology
Expiration and inspiration are both under monitoring
Ensure the accuracy of Vt monitoring
Monitoring Parameter Interface
Main Interface
Boaray 5000D Ventilator
14. Perfect Monitoring Function
Monitoring over 20 respiratory
parameters: airway resistance,
compliance, PEEP, I:E, etc.
Original imported CO2 and SPO2
monitoring function
4 Waveforms OSD:
Pressure-Time
Flow -Time
Volume-Time
CO2 - Time
SPO2 - Time
4 Loops to select:
Volume - Pressure
Flow - Volume
Flow - Pressure
Volume - CO2
Boaray 5000D Ventilator
15. Trend charts of 6 parameters display in the same time.
Data of 1-24 hours can be stored and observed.
Perfect Monitoring Function
Boaray 5000D Ventilator
16. Intelligent Alarm Function
3 Levels of Intelligent Alarm
Tone: < 100 seconds, you can press the alarm mute button
Color: yellow, red
Text: alarm information
Alarm setting: Select the parameters to be set and set
upper and lower limits by touching screen or flying shuttle.
Upper and Lower Limits Setting
Alarm Mute Countdown Alarm Mute Button
Boaray 5000D Ventilator
18. 5000D Comparison
Model Prunus
5000D
Mindray
SV600
Mindray
SV300
Aeonmed
VG70
Prunus Advantage
Display 15 inch 15 inch 12 inch 12 inch Large screen for ease use
Special feature Free Flow,HFNC;TVe/IBW
monitoring
AMV,HFN
C,TVe/IBW
HFNC,TVe/
IBW
/ Better human-ventilator coordination
Tidal Volume 20-3000ml 2-4000 20-2000 20-2000 /
Flow Trigger 0.5-20 0.5-20 0.5-15 0.5-20 /
Pressure trigger -20-0 -20-0.5 -10-0.5 -20~0 /
SpO2 monitoring Optional Optional Optional No More monitoring feature
DualPAP support PS
on high level
Yes No No No Better human-ventilator coordination
Psupp 0-100 0-100 0-80 0-70 Pnuematic ventilator, better performance.
Pinsp 1-100 1-100 5-80 5-70 Pnuematic ventilator, better performance.
Air compressor Yes No No No Lifetime of Prunus pump up to: 100,000
Normal turbine: <20,000h
Longer lifetime saves cost.