- 1. Copyright © 2015 Stryker
NV00014539.AA | Page 1 of 10
INTRODUCTION TO
NEUROFORM ATLAS
Caution: Investigational device. Limited by Federal
(United States) law to investigational use.
- 2. Copyright © 2015 Stryker
NV00014539.AA | Page 2 of 10
The Neuroform Atlas Stent System is indicated for use with
bare metal embolic coils for the treatment of wide-neck
intracranial, saccular aneurysms arising from a parent
vessel with a diameter of greater than or equal to 2mm and
less than or equal to 4.5mm. Wide-neck aneurysms are
defined as having a neck greater or equal to 4mm or a
dome-to-neck ratio of less than 2.
FDA -- Indications For Use
- 3. Copyright © 2015 Stryker
NV00014539.AA | Page 3 of 10
1. Designed for all sizes of the stent to be delivered
through 0.0165in (e.g. SL-10) or 0.017in (e.g. XT-
17) microcatheter
2. Design is optimized for conformability
3. Designed for superior deployment ease & accuracy
4. Designed for feature improved coil scaffolding
Top Performance Criteria
- 4. Copyright © 2015 Stryker
NV00014539.AA | Page 4 of 10
Key Geometry Attributes
Distal Proximal
Closed cell proximal end
designed to aid in stent
stability during lumen
recross.
8 cell structural
elements designed
to provide support
and anchoring
12 cell structural
elements designed
to provide flexibility,
improve scaffolding,
and prevent
‘gapping’ on a bend
Open cell distal end
designed to aid in
stent conformability
and track
Neuroform
Atlas
Neuroform®
All photographs taken by Stryker Neurovascular. All illustrations provided by Stryker Neurovascular.
- 5. Copyright © 2015 Stryker
NV00014539.AA | Page 5 of 10
• All Neuroform Atlas Stent sizes fit through a small
microcatheter (0.0165in or 0.017in)
Microcatheter Compatibility
From this:
0.027in ID
To this:
0.0165in ID
All photographs taken by Stryker Neurovascular.
- 6. Copyright © 2015 Stryker
NV00014539.AA | Page 6 of 10
• Atlas cells are designed to have an improved coil scaffold
while retaining microcatheter recrossability.
Unique Cell Architecture
“Nano”
Sized
Re-crossable
All photographs taken by Stryker Neurovascular.
- 7. Copyright © 2015 Stryker
NV00014539.AA | Page 7 of 10
• Lowest track force required to advance stent
Ease of Access
>50% lower track force
Data analysis performed by Stryker Neurovascular. Data are on file at Stryker Neurovascular and will be made available upon request.
4.5 x 30mm Neuroform
Atlas + Excelsior® XT-17®
Microcatheter
4.5 x 30mm Neuroform
Atlas + Excelsior® SL-10®
Microcatheter
4.5 x 30mm Neuroform +
Excelsior ® XT-27®
Microcatheter
- 8. Copyright © 2015 Stryker
NV00014539.AA | Page 8 of 10
Atlas: Product Matrix
9mm Tip Zero Tip
All photographs taken by Stryker Neurovascular.
Labeled Stent
Diameter (mm)
Indicated Vessel
Range (mm)
Unconstrained Stent
Diameter (mm)
Stent Working Lengths
(mm)
3.0 2.0 - 3.0 3.5 15 21 24 30
4.0 3.0 - 4.0 4.5 15 21 24 30
4.5 4.0 - 4.5 5.0 15 21 24 30
- 9. Copyright © 2015 Stryker
NV00014539.AA | Page 9 of 10
Atlas: Unique Scaffold
Hybrid design can
reduce bifurcation neck
Hybrid design can
appose on tight curves
All photographs taken by Stryker Neurovascular. Sample images represent expected performance of Atlas Stent.
Hybrid design can
conform to anatomy while
maintaining recrossability
- 10. Copyright © 2015 Stryker
NV00014539.AA | Page 10 of 10
Disclaimers
• Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Excelsior, Neuroform,
Neuroform Atlas, Neuroform EZ, SL-10, XT-17, XT-27. All other trademarks are trademarks of their respective owners or holders.
Editor's Notes
- PSST Reference:
DIOVV Atlas: NV00001855
Tip Photos: NV00006394
Nfez 19MM tIP
- PSST Photo Reference:
MCA model: NV00002188
Lateral view: NV00002188