Firestop Filler Boards4 Hour rated
VEDAFEU FBB
S
Y
S
T
E
M
Form
work
-Fire
barrier
Therm
aland
acoustic
insulation
ALL-IN-ONE
© All rights reserved - Non contractual drawings - 01/2016
2
Description
VEDAFEU FB©
firestop filler boards are made of high density mineral wool and are used as fire barrier for
expansion joints.
Packaging
Delivered in 1200 mm long boards with a standard height of 200 mm (other heigths available upon request).
VEDAFEU FB
©
FIRESTOP FILLER BOARDS
All-in-one system : formwork, fire barrier,
thermal and acoustic insulation
1. Attach the anchoring springs at 30 mm from
a long edge of the VEDAFEU FB©
firestop
filler board on Side A.
4. Attach the anchoring springs at 30 mm from
the other long edge of the VEDAFEU FB©
firestop
filler board on Side B.
2. Install the VEDAFEU FB©
firestop filler board
along the wooden formwork.
3. Concrete slab sideupoured.
5. Concrete slab sidevpoured.
u
u
v
v
Side A
u
u
vv
Side B
Side A
Installation instructions
Technical Data
100%
PATENTED
Initial opening 20 to 60 mm
Orientation Horizontal and vertical
Fire resistance EI 240 (4 hours) in compliance with applicable European regulations (EN 1366-4 and EN 13501-2)
Movement Opening up to +20 % - Closing up to -60 %
Minimum height Certified from a 140 mm height
Installation Anchoring springs on one side, springs or adhesive on the other
Thermal conductivity (Lambda) 0,039 W.m-1
K-1
(Report n° RA.15.36.EB-V2 dated 25/10/2015)
Sound attenuation Up to 43 dB (Report n°BEB2.F.6023 dated 09/07/2015)
In case of installation with adhesive, glue
the upper part of the board to the dry
concrete on a 40 mm height and resume
to step 4.
ILLUSTRATIONS
Concrete slab
sidevto be poured.
Positioning at the base of the formwork Installation of anchoring springs
VEDAFEU FB©
firestop filler boards
ready for
concrete pouring
Concrete slab
sideupoured.
© All rights reserved - Non contractual drawings - 01/2016
4
OFFICIAL CLASSIFICATION OF
VEDAFEU FB©
FIRESTOP FILLER BOARDS
■ Tested in horizontal configuration with movement (also valid without or less
movement) for a minimum height of 140 mm (also valid for superior heights)
■ Certified movements : 	 +20% for openings up to 40 mm
				 +15% for openings up to 60 mm
■ Installation method : anchoring springs on both sides
■ Tested in vertical configuration with movement (also valid without or less movement) 	
for a minimum height of 160 mm (also valid for superior heights)
■ Certified movements : 	 +20% for a 20 mm opening
				 +7.5% for openings up to 60 mm
■ Installation method : anchoring springs on one side and adhesive on the other
 
Classification Report n° 13-F-131441 dated 16/04/2014
VERTICAL
EI 240 – V – M7,5 – B – W 20 to 60EI 240 – V – M20 – B – W 20
Classification Report n° 12-F-148 dated 01/03/2012
HORIZONTAL
EI 240 – H – M15 – B – W 20 to 60EI 240 – H – M20 – B – W 20 to 40
EI : E = Firestop Integrity I = thermal insulation. EI expressed in minutes.
H or V : H = horizontal construction support. V = vertical construction support.
M or X : M = movement. X = no movement. M and X expressed in percentage.
B or F : junction type. B = factory and on-site manufactured. F = on-site manufactured.
W = tested joint width. Expressed in millimeters.
Fire resistance according to standard EN 13501-2.
Fireproofing
& Thermal
insulation
in minutes
Horizontal
support
H
Movement
of
+50 %
Initial approved
joint
560 mm
240
minutes
Vertical
support
V
Junction
type
EI 240 - V - M20 - B - W 20 to 120 mm
EI 240 - H - M50 - B - W 560
VALID for width
from
20 to 120 mm
HOW TO READ A CLASSIFICATION REPORT ?
Example of classification
E 60 - H - X - F - W 60
VALID for a
gap of 60 mm
ONLY.
Not valid for
a range
Failed after
60 minutes
NO «I»
NO THERMAL
INSULATION
HORIZONTAL
SUPPORT
ONLY
Tested
WITHOUT MOVEMENT
© All rights reserved - Non contractual drawings - 01/2016
6
ADVANTAGES OF THE ALL-IN-ONE
VEDAFEU FB©
SYSTEM
■ VEDAFEU FB©
firestop filler boards are an all-in-one system :
	 - They replace the expansion joint formwork usually used on site (alveolar cardboard, 	
	 polystyrene…)
	 - They make the joint fireproof (EI 240 – 4-hour fire resistance) on the whole thickness
	 of the slab or the wall. Fire can thus come from any side.
■ The use of VEDAFEU FB©
firestop filler boards allows to skip steps in the making and
fireproofing of expansion joints as shown on the below chart :
On top of the savings on material and labor, the use of VEDAFEU FB©
firestop filler boards in
expansion joints allows a better environmental impact : they reduce the carbon footprint, increase
productivity, remove waste and its management as well as the removing of the formwork.
Standard
method
Removing formwork
Cleaning
(waste management…)
Fireproofing
with another solution
Expansion joint formwork
Concrete pouring
Fireproof expansion joint
Alveolar cardboard,
polystyrene…
VEDAFEU FB©
+
springs
+
adhesive
VEDAFEU FB©
firestop
filler boards
{STEPS SKIPPED WITH
THE USE OF
VEDAFEU FB© FIRESTOP
FILLER BOARDS
FAST
ECOLOGICAL
ECONOMICAL
OTHER ADVANTAGES
Junction between two boards
The patented linking system guarantees the integrity
of the product at junctions. It also guarantees the same
acoustic and fire performance on the whole length, eases
installation and improves airtightness.
Thermal and acoustic insulation
VEDAFEU FB©
firestop filler boards allow a good
thermal (lambda 0.039 as per report n° RA.15.36-EB-V2
dated october 25th
2015) and acoustic (up to 43 dB
reduction as per report n° BEB2.F.6023 dated July 9th
2015) insulation. They can therefore be used in High
Environmental Quality buildings. Official reports are
available upon request.
Adhesion to concrete
As per their installation method, concrete is always
poured on at least one side of the VEDAFEU FB©
firestop
filler boards which guarantees a perfect adhesion with
no risk to see the product fall with time. Moreover, the
high density of the wool gives an excellent resistance
to infiltration and physical agressions.
Ancillary products
No ancillary product is mandatory to ensure fire
resistance.
GV2 - VEDA FRANCE - CS 63052 - 95972 Roissy CDG Cedex - France
Tél : + 33 (0)1 48 61 70 80 - Fax : + 33 (0)1 48 61 70 81 - Web : www.vedafrance.com - E-mail : export@vedafrance.com

More Related Content

What's hot

GRC Cable Trough & Elevated Channel - Rail Cable Protection & Support
GRC Cable Trough & Elevated Channel - Rail Cable Protection & SupportGRC Cable Trough & Elevated Channel - Rail Cable Protection & Support
GRC Cable Trough & Elevated Channel - Rail Cable Protection & SupportThorne & Derrick International
 
Avantis 70 - Avantis 75 aluminium windows and door by Sapa Building System
Avantis 70 - Avantis 75 aluminium windows and door by Sapa Building SystemAvantis 70 - Avantis 75 aluminium windows and door by Sapa Building System
Avantis 70 - Avantis 75 aluminium windows and door by Sapa Building SystemSapa Building System
 
Bricks & Blocks brochure
Bricks & Blocks brochureBricks & Blocks brochure
Bricks & Blocks brochurekristenjames
 
Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools
Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools
Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools Thorne & Derrick International
 
Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...
Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...
Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...Thorne & Derrick International
 
SMM7 Bill of Quantities
SMM7 Bill of QuantitiesSMM7 Bill of Quantities
SMM7 Bill of QuantitiesNatalie Reid
 
VG Check list using JCB near track rev 00
VG Check list using JCB near track rev 00VG Check list using JCB near track rev 00
VG Check list using JCB near track rev 00Varadharajalu Gopal
 
M3 EG BQ steel struture
M3 EG BQ steel strutureM3 EG BQ steel struture
M3 EG BQ steel strutureEst
 
Made with 8020_stuff_material_handling_flipbook
Made with 8020_stuff_material_handling_flipbookMade with 8020_stuff_material_handling_flipbook
Made with 8020_stuff_material_handling_flipbookThe Knotts Company
 
French Door Pairs – Assembly Instructions
French Door Pairs – Assembly InstructionsFrench Door Pairs – Assembly Instructions
French Door Pairs – Assembly InstructionsHelen Smith
 
Avantis 95 Passiv Haus aluminium window and door system by Sapa Building System
Avantis 95 Passiv Haus aluminium window and door system by Sapa Building SystemAvantis 95 Passiv Haus aluminium window and door system by Sapa Building System
Avantis 95 Passiv Haus aluminium window and door system by Sapa Building SystemSapa Building System
 
Clean room system tarkett
Clean room system tarkettClean room system tarkett
Clean room system tarkettCutting Corners
 
No tie lace-system
No tie lace-systemNo tie lace-system
No tie lace-systemRyan McMahon
 

What's hot (18)

BQ
BQBQ
BQ
 
GRC Cable Trough & Elevated Channel - Rail Cable Protection & Support
GRC Cable Trough & Elevated Channel - Rail Cable Protection & SupportGRC Cable Trough & Elevated Channel - Rail Cable Protection & Support
GRC Cable Trough & Elevated Channel - Rail Cable Protection & Support
 
Avantis 70 - Avantis 75 aluminium windows and door by Sapa Building System
Avantis 70 - Avantis 75 aluminium windows and door by Sapa Building SystemAvantis 70 - Avantis 75 aluminium windows and door by Sapa Building System
Avantis 70 - Avantis 75 aluminium windows and door by Sapa Building System
 
Advanced nbs grid_ceiling(1)
Advanced nbs grid_ceiling(1)Advanced nbs grid_ceiling(1)
Advanced nbs grid_ceiling(1)
 
Bricks & Blocks brochure
Bricks & Blocks brochureBricks & Blocks brochure
Bricks & Blocks brochure
 
Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools
Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools
Weicon Low Voltage (LV) Cable Strippers - Cable Stripping Tools
 
12777 coastal single pages part138
12777  coastal single pages part13812777  coastal single pages part138
12777 coastal single pages part138
 
Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...
Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...
Captrad Cable Systems - GRP Cable Tray, GRP Cable Troughs, Recycled Plastic C...
 
ContainAire
ContainAire ContainAire
ContainAire
 
SMM7 Bill of Quantities
SMM7 Bill of QuantitiesSMM7 Bill of Quantities
SMM7 Bill of Quantities
 
VG Check list using JCB near track rev 00
VG Check list using JCB near track rev 00VG Check list using JCB near track rev 00
VG Check list using JCB near track rev 00
 
Gamma industries
Gamma industries Gamma industries
Gamma industries
 
M3 EG BQ steel struture
M3 EG BQ steel strutureM3 EG BQ steel struture
M3 EG BQ steel struture
 
Made with 8020_stuff_material_handling_flipbook
Made with 8020_stuff_material_handling_flipbookMade with 8020_stuff_material_handling_flipbook
Made with 8020_stuff_material_handling_flipbook
 
French Door Pairs – Assembly Instructions
French Door Pairs – Assembly InstructionsFrench Door Pairs – Assembly Instructions
French Door Pairs – Assembly Instructions
 
Avantis 95 Passiv Haus aluminium window and door system by Sapa Building System
Avantis 95 Passiv Haus aluminium window and door system by Sapa Building SystemAvantis 95 Passiv Haus aluminium window and door system by Sapa Building System
Avantis 95 Passiv Haus aluminium window and door system by Sapa Building System
 
Clean room system tarkett
Clean room system tarkettClean room system tarkett
Clean room system tarkett
 
No tie lace-system
No tie lace-systemNo tie lace-system
No tie lace-system
 

Similar to VEDAFEU FB - 01-2016

3x engineering product
3x engineering product3x engineering product
3x engineering productPôle Mer
 
01 verso en_0703
01 verso en_070301 verso en_0703
01 verso en_0703Adit Group
 
03 SISTEME ANTIFOC PENTRU ROSTURI STRUCTURALE SEISMIMCE
03  SISTEME ANTIFOC  PENTRU ROSTURI STRUCTURALE SEISMIMCE03  SISTEME ANTIFOC  PENTRU ROSTURI STRUCTURALE SEISMIMCE
03 SISTEME ANTIFOC PENTRU ROSTURI STRUCTURALE SEISMIMCEREDA SRL
 
Tukang gypsum terdekat 081381278719.pdf
Tukang gypsum terdekat 081381278719.pdfTukang gypsum terdekat 081381278719.pdf
Tukang gypsum terdekat 081381278719.pdftukang_gypsum
 
DualProof Brochure
DualProof BrochureDualProof Brochure
DualProof BrochureSURFASOLOGY
 
Product_Overview_04.05.2016_EN
Product_Overview_04.05.2016_ENProduct_Overview_04.05.2016_EN
Product_Overview_04.05.2016_ENTim Long
 
Schiedel Metaloterm MFflue system
Schiedel Metaloterm MFflue systemSchiedel Metaloterm MFflue system
Schiedel Metaloterm MFflue systemSchiedel UK
 
Sealing solutionsfor building and industrial installation
Sealing solutionsfor building and industrial installationSealing solutionsfor building and industrial installation
Sealing solutionsfor building and industrial installationMartin Franke
 
VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...
VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...
VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...IndiaMART InterMESH Limited
 
Alroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon Layer
Alroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon LayerAlroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon Layer
Alroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon LayerThorne & Derrick International
 
ICID Plus Brochure
ICID Plus Brochure ICID Plus Brochure
ICID Plus Brochure Schiedel UK
 
Fibrovia® - Fibre for durability
Fibrovia® - Fibre for durabilityFibrovia® - Fibre for durability
Fibrovia® - Fibre for durabilityEurovia_Group
 
FRIUL FILIERE SPA COMPANY PROFILE
FRIUL FILIERE SPA COMPANY PROFILEFRIUL FILIERE SPA COMPANY PROFILE
FRIUL FILIERE SPA COMPANY PROFILELuna Artico
 

Similar to VEDAFEU FB - 01-2016 (20)

3x engineering product
3x engineering product3x engineering product
3x engineering product
 
01 verso en_0703
01 verso en_070301 verso en_0703
01 verso en_0703
 
03 SISTEME ANTIFOC PENTRU ROSTURI STRUCTURALE SEISMIMCE
03  SISTEME ANTIFOC  PENTRU ROSTURI STRUCTURALE SEISMIMCE03  SISTEME ANTIFOC  PENTRU ROSTURI STRUCTURALE SEISMIMCE
03 SISTEME ANTIFOC PENTRU ROSTURI STRUCTURALE SEISMIMCE
 
Tukang gypsum terdekat 081381278719.pdf
Tukang gypsum terdekat 081381278719.pdfTukang gypsum terdekat 081381278719.pdf
Tukang gypsum terdekat 081381278719.pdf
 
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
CAME - BX OPERATOR FOR SLIDING GATES WEIGHING UP TO 800 k G (1,760 L b)
 
Ventilated Facade Systems
Ventilated Facade SystemsVentilated Facade Systems
Ventilated Facade Systems
 
DualProof Brochure
DualProof BrochureDualProof Brochure
DualProof Brochure
 
Product_Overview_04.05.2016_EN
Product_Overview_04.05.2016_ENProduct_Overview_04.05.2016_EN
Product_Overview_04.05.2016_EN
 
Schiedel Metaloterm MFflue system
Schiedel Metaloterm MFflue systemSchiedel Metaloterm MFflue system
Schiedel Metaloterm MFflue system
 
Sealing solutionsfor building and industrial installation
Sealing solutionsfor building and industrial installationSealing solutionsfor building and industrial installation
Sealing solutionsfor building and industrial installation
 
VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...
VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...
VRTS Industrial Solutions Private Limited, Noida, Industrial And Automotive P...
 
Alroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon Layer
Alroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon LayerAlroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon Layer
Alroc K7/FNS Blade Support With Blade LFNS For Bonded Semicon Layer
 
Filoform Duct Sealing Brochure
Filoform Duct Sealing BrochureFiloform Duct Sealing Brochure
Filoform Duct Sealing Brochure
 
Dual proof e 2016
Dual proof e 2016Dual proof e 2016
Dual proof e 2016
 
ICID Plus Brochure
ICID Plus Brochure ICID Plus Brochure
ICID Plus Brochure
 
RISE Insert Sleeves
RISE Insert Sleeves RISE Insert Sleeves
RISE Insert Sleeves
 
Water, Gas & Fire Tight CSD RISE Duct Sealing System
Water, Gas & Fire Tight CSD RISE Duct Sealing SystemWater, Gas & Fire Tight CSD RISE Duct Sealing System
Water, Gas & Fire Tight CSD RISE Duct Sealing System
 
Fibrovia® - Fibre for durability
Fibrovia® - Fibre for durabilityFibrovia® - Fibre for durability
Fibrovia® - Fibre for durability
 
FRIUL FILIERE SPA COMPANY PROFILE
FRIUL FILIERE SPA COMPANY PROFILEFRIUL FILIERE SPA COMPANY PROFILE
FRIUL FILIERE SPA COMPANY PROFILE
 
Filoform fibre optic flyer
Filoform fibre optic flyerFiloform fibre optic flyer
Filoform fibre optic flyer
 

VEDAFEU FB - 01-2016

  • 1. GV2 - VEDA FRANCE - CS 63052 - 95972 Roissy CDG Cedex - France Tél : + 33 (0)1 48 61 70 80 - Fax : + 33 (0)1 48 61 70 81 - Web : www.vedafrance.com - E-mail : export@vedafrance.com Firestop Filler Boards4 Hour rated VEDAFEU FBB S Y S T E M Form work -Fire barrier Therm aland acoustic insulation ALL-IN-ONE
  • 2. © All rights reserved - Non contractual drawings - 01/2016 2 Description VEDAFEU FB© firestop filler boards are made of high density mineral wool and are used as fire barrier for expansion joints. Packaging Delivered in 1200 mm long boards with a standard height of 200 mm (other heigths available upon request). VEDAFEU FB © FIRESTOP FILLER BOARDS All-in-one system : formwork, fire barrier, thermal and acoustic insulation 1. Attach the anchoring springs at 30 mm from a long edge of the VEDAFEU FB© firestop filler board on Side A. 4. Attach the anchoring springs at 30 mm from the other long edge of the VEDAFEU FB© firestop filler board on Side B. 2. Install the VEDAFEU FB© firestop filler board along the wooden formwork. 3. Concrete slab sideupoured. 5. Concrete slab sidevpoured. u u v v Side A u u vv Side B Side A Installation instructions Technical Data 100% PATENTED Initial opening 20 to 60 mm Orientation Horizontal and vertical Fire resistance EI 240 (4 hours) in compliance with applicable European regulations (EN 1366-4 and EN 13501-2) Movement Opening up to +20 % - Closing up to -60 % Minimum height Certified from a 140 mm height Installation Anchoring springs on one side, springs or adhesive on the other Thermal conductivity (Lambda) 0,039 W.m-1 K-1 (Report n° RA.15.36.EB-V2 dated 25/10/2015) Sound attenuation Up to 43 dB (Report n°BEB2.F.6023 dated 09/07/2015) In case of installation with adhesive, glue the upper part of the board to the dry concrete on a 40 mm height and resume to step 4.
  • 3. ILLUSTRATIONS Concrete slab sidevto be poured. Positioning at the base of the formwork Installation of anchoring springs VEDAFEU FB© firestop filler boards ready for concrete pouring Concrete slab sideupoured.
  • 4. © All rights reserved - Non contractual drawings - 01/2016 4 OFFICIAL CLASSIFICATION OF VEDAFEU FB© FIRESTOP FILLER BOARDS ■ Tested in horizontal configuration with movement (also valid without or less movement) for a minimum height of 140 mm (also valid for superior heights) ■ Certified movements : +20% for openings up to 40 mm +15% for openings up to 60 mm ■ Installation method : anchoring springs on both sides ■ Tested in vertical configuration with movement (also valid without or less movement) for a minimum height of 160 mm (also valid for superior heights) ■ Certified movements : +20% for a 20 mm opening +7.5% for openings up to 60 mm ■ Installation method : anchoring springs on one side and adhesive on the other   Classification Report n° 13-F-131441 dated 16/04/2014 VERTICAL EI 240 – V – M7,5 – B – W 20 to 60EI 240 – V – M20 – B – W 20 Classification Report n° 12-F-148 dated 01/03/2012 HORIZONTAL EI 240 – H – M15 – B – W 20 to 60EI 240 – H – M20 – B – W 20 to 40
  • 5. EI : E = Firestop Integrity I = thermal insulation. EI expressed in minutes. H or V : H = horizontal construction support. V = vertical construction support. M or X : M = movement. X = no movement. M and X expressed in percentage. B or F : junction type. B = factory and on-site manufactured. F = on-site manufactured. W = tested joint width. Expressed in millimeters. Fire resistance according to standard EN 13501-2. Fireproofing & Thermal insulation in minutes Horizontal support H Movement of +50 % Initial approved joint 560 mm 240 minutes Vertical support V Junction type EI 240 - V - M20 - B - W 20 to 120 mm EI 240 - H - M50 - B - W 560 VALID for width from 20 to 120 mm HOW TO READ A CLASSIFICATION REPORT ? Example of classification E 60 - H - X - F - W 60 VALID for a gap of 60 mm ONLY. Not valid for a range Failed after 60 minutes NO «I» NO THERMAL INSULATION HORIZONTAL SUPPORT ONLY Tested WITHOUT MOVEMENT
  • 6. © All rights reserved - Non contractual drawings - 01/2016 6 ADVANTAGES OF THE ALL-IN-ONE VEDAFEU FB© SYSTEM ■ VEDAFEU FB© firestop filler boards are an all-in-one system : - They replace the expansion joint formwork usually used on site (alveolar cardboard, polystyrene…) - They make the joint fireproof (EI 240 – 4-hour fire resistance) on the whole thickness of the slab or the wall. Fire can thus come from any side. ■ The use of VEDAFEU FB© firestop filler boards allows to skip steps in the making and fireproofing of expansion joints as shown on the below chart : On top of the savings on material and labor, the use of VEDAFEU FB© firestop filler boards in expansion joints allows a better environmental impact : they reduce the carbon footprint, increase productivity, remove waste and its management as well as the removing of the formwork. Standard method Removing formwork Cleaning (waste management…) Fireproofing with another solution Expansion joint formwork Concrete pouring Fireproof expansion joint Alveolar cardboard, polystyrene… VEDAFEU FB© + springs + adhesive VEDAFEU FB© firestop filler boards {STEPS SKIPPED WITH THE USE OF VEDAFEU FB© FIRESTOP FILLER BOARDS FAST ECOLOGICAL ECONOMICAL
  • 7. OTHER ADVANTAGES Junction between two boards The patented linking system guarantees the integrity of the product at junctions. It also guarantees the same acoustic and fire performance on the whole length, eases installation and improves airtightness. Thermal and acoustic insulation VEDAFEU FB© firestop filler boards allow a good thermal (lambda 0.039 as per report n° RA.15.36-EB-V2 dated october 25th 2015) and acoustic (up to 43 dB reduction as per report n° BEB2.F.6023 dated July 9th 2015) insulation. They can therefore be used in High Environmental Quality buildings. Official reports are available upon request. Adhesion to concrete As per their installation method, concrete is always poured on at least one side of the VEDAFEU FB© firestop filler boards which guarantees a perfect adhesion with no risk to see the product fall with time. Moreover, the high density of the wool gives an excellent resistance to infiltration and physical agressions. Ancillary products No ancillary product is mandatory to ensure fire resistance.
  • 8. GV2 - VEDA FRANCE - CS 63052 - 95972 Roissy CDG Cedex - France Tél : + 33 (0)1 48 61 70 80 - Fax : + 33 (0)1 48 61 70 81 - Web : www.vedafrance.com - E-mail : export@vedafrance.com