EFFECT ON SHEAR IN DEEP BEAM BY USING CRIMPED STEEL FIBER
Rehabilitation of insufficient anchorage bar lengths
1. Rehabilitation of insufficient anchorage bar
lengths according to EN 1998 and the
Greek rehabilitation code KAN.EPE
Andreas Kalantzis / Civil Engineer
2. Anchorage bar length
Is the required reinforcement bar length in order to transfer
safely the forces (axial, moment, shear) from one bar to
another without failure of the concrete – steel interface.
Imposed:
By the steel industry(reinforced bar with length >10 m is
difficult to attach).
In order to installed and transferred properly to the site.
Usually encountered outside the critical zone of a column .
3. Rehabilitation of insufficient anchorage bar lengths
Failure mechanism: The concrete is unable to receive and
transfer the forces/stresses and it cracks allowing the
reinforcement bar to slide (in a non ductile type of failure).
Main object: The enforcement of an outer confinement that
will create compression stresses to the element in concretes
attempts to enlarge with tensile stresses.
A non destructive method is the use of FRP materials(fibre
reinforced polymer).
4. Fibre Reinforced Polymer materials(F.R.P)
Advance and compose materials that consists of a
polymer(epoxy)matrix reinforced with fibers.
Carbon, aramid and glass fibers.
Advantages : extremely high tensile resistance, durability in
corrosion, low self weight, easy and rapid attachment.
Disadvantages: notable cost of persuasion, poor performance
in high temperatures, zero ductility.
7. ΚΑΝ.ΕPΕ 2012
ΚΑΝ.ΕPΕ
§8.2.1.2 figure. 8.3
In case of a constant cloak made from frp materials the ratio
Αj/s is the required thickness tj of the cloak.
8. ΚΑΝ.ΕPΕ 2012
γrd=1.5 : safety coefficient for the uncertainty of the simulation .
: the total area of reinforcement bar.
: is the enforced design axial stress of the confinement
elements.
λs : coefficient that describes the contribution of the all ready
attached(the insufficient)anchorage bar length. It is advised to be taken
λs = 0.
9. ΚΑΝ.ΕPΕ 2012
ls : the reinforcement bar length
: bf the wide of friction area along the crack of the
anchorage bars and Β is the wide distribution
of the total shear force that delivers the axial force from
the frp material material confinement( for c / ds ≤2
the value of β is near 1.0).
μ : friction factor that depends on the magnitude of the compression
stresses between the crack interface as well from the acceptable sliding of
the bar. μ takes values from 0,4 to 2,0. Luck of data someone can consider
μ=1,0 .
10. Notations of ΚΑΝ.ΕPΕ 2012
Για τη εφαρμογή της τεχνικής πρέπει :
The attached(insufficient) anchorage length ls should be grater than
0.30 lso and 15 ds
The length of the element in which we will apply the confinement should
have at list the length of the critical zone and no less than 1,3 ls ή 0.60 m .
Thickness t j ≥ 25 mm
εjd= √2 wd / b , where wd =0.6 sd
2/3 while sd 0.3 for performativity
level Α and 0.4 for Β while C, b = (b1 +b2)/2 .
11. Example according to ΚΑΝ.ΕPΕ 2012
Material: Sika Wrap 600C/120 : tj=0.337mm ,E=242GPa , perf. Level Β
Φ18 , fyk=330 Mpa , 400mm x 200mm , Ab =π182/4=254.5mm
lso =Φ fyd/4 fbd= 782mm , 0,3x782=234.6mm , at least ls=210mm
ΚΑΝ.ΕPΕ
§8.2.1.2 , rel. 8.3
1.61mm/0.337mm=4.77 ≈ 5 layers
Για κ ≥ 4 layers , tj =ψ κ tj με ψ=κ-1/4 where ψ the reduced efficiency
coefficient of multi layering. ΚΑΝ.ΕPΕ
We are choosing 8 layers of material § 6.2.3
12. EN1998-3
According to §Α4.4.4(tightening of the bonds by overlaping the bars )of the Α
annex of ΕΝ 1998-3
( ΕΝ1998-3 , §Α.4.4.4 , Α.37 )
σsw=0,001ρwEs
For orthogonical columns D is the wide bW of the cross section§A.4.4.4(2)
Εf is the modulus of elasticity for the frp material
13. EN1998-3
EN 1998-3 , §Α.4.4.4 , (Α.38)
Α s the area of every reinforced bar that is been overlped.
fyl the yield bound of steel that can be taken equal to the middle value,
multiplied properly with the so called trust coefficient CF ( ΕΝ 1998-3 §3.3 )
p the perimeter of the column measured from the inner side of the longitudinal
reinforcement bar.
14. EN1998-3
dbl the maximum diameter of the longitudinal reinforced bars
c thickness of concrete cover.
Ls the anchorage length
n the number of the overlapped bars along p
15. Example according to EN1998-3
For orthogonical column: CFΕΓ3=1.0, c=30mm, tf=0.337mm , fyk = 330
400 6Φ18, Ef =242GPa
Φ 200
( EN1998-3 A.4.4.4 , A.37 )
1.1mm/0.337mm = 3 layers
17. Conclusions
The relation8.3 of ΚΑΝ.ΕPΕ proved conservative compared to relation
Α.37 of EN1998-3 and thus it gives grater values of material thickness.
Bigger thickness of frp material leads to small number of layers.
Performativity level Β and C ( ΚΑΝ.ΕΠΕ §8.2.1.2 , β , ii ) leads to bigger
values of deformation εjd .